Loading...
HomeMy WebLinkAboutSW3200102_1735 Heilig Road (03-12-2019)_1/17/2020/ \ PROPOSED PASE I DEVELOPMENT SUMMARY \ PROJECT NAME: BUILDING EXPANSION FOR 1735 HEILIG ROAD NOW OR FORMERLY / C` \ OWNER: IOM ENTERPRISES, LLC CITY OF SALISBURY / PARCEL P.I.N.: 402 021 D.B. 786 PG. 108 TAX MAP 402 PARCEL 67 / L / \ \\ CIVIL SITE DESIGN PLANS PREPARED BY: AMICUS PARTNERS, PLLC \ ZONING = RS C PHONE: 704-573- 1 G2 1 / \ ✓ II ZONING: LI / CBI JURISDICTION: CITY OF GRANITE QUARRY/ROWAN COUNTY NOW OR FORMERLY / CITY OF SALISBURY / \ / � � � ?� � SETBACK (EAST): 10 FT (NORTH): 25 FT Firm License # P-1191 D.B. 786 PG. 823 \ / — / I TI APP�R,�O�XI EXI ING ° TAX MAP 402 PARCEL 68 / — // �/ N wHTER M (SOUTH): 30 FT (WEST): I O FT 7140 WSdde 140 on Road / / LOT SIZE: I 159, 13 I .G 2G.G I SQ. FT ACRES Concord, NC 28027 ZONING = RS / — — � � � / / � / / . C / 5 ' EXISTING USE: MANUFACTURING AND WAREHOUSE Civil Site Design / < MET€R- / UTILIT / Bpy� / / BOX Es �� Low Impact Development / APPROXIMATE JURISDICTIO4LINE — B LA IC �- PROPOSED USE: MANUFACTURING AND WAREHOUSE — _\ �� — \ �// SIC NUMERIC CODE: 1 54 I Small Scale Building Design /�� \ I \ Telephone: 704.573.1621 7) ( PVMT�% EXISTING PARKING: 1 29 SPACES Facsimile: 704.248.7951 4tP Q101, EXISTING HANDICAP PARKING: G SPACES \ /T>/N'y/8�1/ \ \`� Seals: 976SFOFASPHALT \ / /� AREA OF EXISTING BUILDING COVERAGE: 1 50, 131 SQ.FT TO BE REMOVED Q \ \ \ \ fl'(�N�// • 11 Latest Revision Revision Revision \ > �// ��� / // �� \ �O AREA OF EXISTING PARKING AND DRIVE COVERAGE: 1 80,42G SQ.FT C(7 rLandscapin,� Title Sheet No. Or1 lnal Date Date Number Note / , L C \ \ J AREA OF EXISTING SIDEWALK COVERAGE: 2,73G SQ.FT �•Q�oFEss�o�9`••y xisting Conditions C-I .O 07/2G/18 03/I 2/I 9 5 Per City of Salisbury / 1 l \\ \ �\ �j TOTAL EXISTING IMPERVIOUS AREA: 333,293 SQ.FT SEAL C-2.0 07 2G 1 8 03 1 2 1 9 / Per City of Salisbury \ �/ 032006 / / / / 5 c / // / / / /� \ H A I �✓ AREA OF P OPOSED BUILDING ADDITION: G7 500 S .FT es Details C-2. I 03/I 2/I 9 - Per City of Salisbury / / \ /�/// ////// / \� / \\ \ �j R R Q Plan C-3.0 Per Town of Granite Quarr � — AREA OF ADDITIONAL PARKING AND DRIVE COVERAGE: 32,24G SQ.FTy•F.c'NE07/2G/ 18 O I / 14/ 19 3 Y I / / /�/� / / OO \ \ \ S �i,• °gas R. PP ��` Phase Erosion Control C-4.0 07/2G/ 1 8 1 1 / 1 3/ 1 8 2 Per Town of Granite Quarry / :� I // T o _ '�5' \ �/ AREA OF IMPERVIOUS TO BE REMOVED: 34,009 SQ.FT ••••••..�•.•••••`. C % / / \ Phase II Erosion Control C-4. I Per Town of Granite Quarry I y �( s �\ \ / _ 07/2G/ 1 8 O 1/ 1 4/ 1 9 3 Y I// l/ 03 12-2019 Erosion Control Details C-5.0 07/2G/ 1 8 01114119 \3 Per Town of Granite Quarry / 1 :� ` / / f r \ \ \ / \ �� \ TOTAL PROPOSED NEW IMPERVIOUS AREA: 99,74G SQ.FT Erosion Control Details C-5. 1 07/2G/ 18 O 1 / 1 4/ 1 9 Per Town of Granite Quarry I / I ` /// 1 9 /� j /� NET INCREASE IN IMPERVIOUS AREA: G5,G87 SQ.FT Storm Water Mana ement Plan C-G.0 07/2G/ 18 O 1 / 1 4/ 1 9 3 Per Town of Granite Quarry Sand Filter Details C-G. I 07/2G/ 1 8 0 1/ 1 4/ 1 9 3 Per Town of Granite Quarry I / C \ / //// / / / \ ✓ '� \\ l PERCENT IMPERVIOUS AREA: 34.42% w 0 9 SITE VICINITY MAP 6 NOT TO SCALE /// FLOOR \ \ =819.76' EXISTING 8" F E 509 DUKE POWER ESNT< PROTECTION L00 \ / / / �� /O / I I J I \ TING (D.B. 782 P G . 9 0 4) / / /// ///4�r��^` / ���r HYDRANT z �1 TB M I ^ �j� TER H z �O / ) EL .=815.28' EXISTING \ HYDRANT DRAIN �' �l x Ui F.FLOOR 4 Z �8� I l/�jlll/ll/ I P I�✓/ �1 /I I 1 I 6� S� \ CM EXIST \\\ EXI 1NG 8 FIRE / \ YDRANT F.FLOOR=819.35' \ 1� PRO TION LOOP /J �/ I DI R ION �\ �� / / �` 1 J I l \ I 1 \ UN OWN / O� IN =8 7.18' /1,11 ° L 80� Cj 5 00 4 PARKING SPACES OHO NOW OR FORMERLY I I / I I ` \ - �O TO BE REMOVED ROWAN COUNTY /� BOARD OF EDUCATION D.B. 179 PG. 294 EXIS IN� 8" IRE TOP H 1 I D.B. 556 PG. 613 TBf�1 I / /�T�CTIdN 1\ / D.B. 623 PG. 343 % \ P\ TAX MAP 402 PARCEL 36 ZONING RS \ / �� Project Number: 17-18-092 � Date: tij / ae:, JJ T ETAL SHEAD �O �lv �� h e 03/ 12/20 19 4W �� \ ✓ O BE REMOVED / 02 �• Q O. DK ���, Opc Q �. Drawn By JRD \ / \ o9%c # / N �jx / �PQ) V tL Checked By: NRP o00 EXISTINCI DU PS ER L�OCA N /y s J / J 16,631 SF OF ASPHALT �O o I / TO BE REMOVED I o �- —�- T�EMAIN v�� / / /� (rr// EX. SED. o Q / o I \ s / �l / I I � � / POND � �P Revisions: % �\ C - - / / I � I 1 � \ � � \\ \\�\\ \ , �P-�- / 07 2G 18 ORIGINAL SUBMITTAL —\ LOOR=83 \\\ \ \ QI I 0-23- 18 PER DEVELOPER ' \ \ / EXI N� \ \\ I % NL \ \\ \\\ \ ` / 1 2-1 G- 18 PfR TOWN of CRANiTE oUARRY b 4,452 FEET OF CONCRETt / / \ \\ O TO BE REMOVED \ / / J P�� Co hQ� \ / O I - 14- 19 PfR TOWN of Cw NiTf ouARRr A 02-1 3- 1 9 PfR CITY of SALISBURY LEGEND / / / / , / 1 ' \ \ EXISTING �, / �,° / / I J J J 111> / �' QG Q�� \ / A 03-1 2- 1 9 PfR CITY of SALISBURY ' HYDRANT ESUBJECT XISTING SANITAPROPERTY SEWER BOUNDARY EXISTING 68' DUKE POWER R W Sheet Title. — EXISTING 50 DUKE POWER EASMENT ADJACENT PROPERTY EXISTING FENCE PROPOSED BUILDING EXPANSION \ \ %// �// \ NO OR OR FORMERLY I l / /// �/ o EXtsTr���6�sFzoaE— / / / / /// %////// \ C / EDNA SMITH W W 709 W W EXISTING WATER LINE \ REMOVED \\ / //////////� / \ � D.B. 1172 PG. 965 I l I ROWAN—SALISBURY C + / / / / / / / \ \ \ / TAX MAP 402 PARCEL 29 EXISTING --- / /i// // / / BOARD OF EDUCATION GRAPHIC SCALE \ \ \ /�// ' D.B. 1245 PG. 658 CONDITIONS � \ / � / � / � \ 60 0 30 60 120 ' TAX MAP 402 PARCEL 86 ZONING = LI RTOP OF OUGHED N D \ �j % / / / \ Sheet No: COPYRIGHT © 2019, AMICUS PARTNERS, PLLC. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTI AND OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS ADJACENT PROPERTIES REFERENCED FROM A SURVEY CONDUCTED BI SOUTIiPOINT DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT SURVEYING. OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VALID, TRUE COPIES. PROPOSED 8" PVC FIRE MAI / \ EXISTING 8" FIRE MAIN TO BE ABANDONE EXISTING FIRE MAIN PIED. TO BE RELOCATE ^ 50 DUKE POWER ESfM /a / IR B. 782 PG. 904 /� P'N (D. / / P. EXISTING FIRE HYDRANT TO BE RELOCATE OUTSIDE OF EXPANSION FOOTPRINT. G.C. TO VERIFY FIRE LINE LOCATION PRIOR TO FOUNDATION CONSTRUCTION/ / �E>Isrikc A I H D _ T NOTE TO THE REVIEWER: I IT IS THE INTENT OF THE OWNER TO INSTALL i A BMP TO TREAT AND DETAIN THE REQUIRED NOTES: STORM EVENTS FOR THE "NET" INCREASE IN I I �2" PVC - 1. ALL 12"X18" ACCESSIBLE SIGNS (R7-8A & R7-1) SHALL BE MOUNTED AT LEAST 7 FEET IMPERVIOUS AREA AS PART OF THE PHASE 11 STUB UP FROM GRADE TO EDGE OF SIGN FACE (MTUCD). MOUNTING HEIGHT CAN BE REDUCED TO 5 FEET I I IF PLACED IN AN AREA BETWEEN SIDEWALK AND BUILDING FACE IN WHICH PEDESTRIANS ARE NOT BUILDING EXPANSION. I EXPECTED TO USE. 2. REFER TO MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), U.S. DEPARTMENT OF e I TRANSPORTATION AND NORTH CAROLINA DEPARTMENT OF TRANSPORTATION SUPPLEMENT. 3. IF ACCESSIBLE ROUTE IS A RAISED SIDEWALK AREA, THEN RAMPS ARE REQUIRED AT LOADING ZONE AREA. 4. MAXIMUM GRADE FOR ACCESSIBLE PARKING AREA IS NOT TO EXCEED 2% IN ANY DIRECTION. SIGNAGE ACCESSIBLE R TE ® © © © (SEE NOTE 3) SEE STD. NO 50.09 FOR DETAILS — I I¢ I CO wl ICO LLJ of IC �I 0 I I I tE� NSIBLEXISTING 8" FIRE SPACE d �'PROTECTION LOOP ONE OUT OF EVERY EIGHT (8)ACCESSIBLE SPACES, BUT NOT LESS THAN ONE, IS REQUIRED TO BE VAN ACCESSIBLE. N n 0 OI PARKING SPACE PAVEMENT MARKINGS /c:5 a, I / O / RESERVED I / VAN R7-8e 1 PARKING MUTCD PARKING ACCESSIBLE 12"x6 R7-1 12"x18" MUTCD SEE STANDARD NO. 50.10E & 50.10C FOR SUPPLEMENTAL SIGN DETAIL N"TES: -.� IIIMENSITRI3 NuSr KAICH SItl EWAIII A1Dm DIMNSI S MUST WATCH CONCRETE 1. V_ INTAIN A MINIMUM OF D.SX SLOPE -ON ALL CONCRETE SURFACES TIC PRCMOTE SURFACE DRAINAGE TOWARD CURB. �}. a TYP_ e' w 5' MINWM (4' w 4MN. PER PROVAD•W) I-M (2. MAX) N ANY RIRECBNN +�. (WALKABLE SURFACE) WHERE 2. GUTTER FLOW LINE AND PLAN PROFILE SHALL BE MAINTAINED THROUGH THE ti PERMITTED RAMP AREA 3. THE SURFACE OF THE RAMP SHALL BE FLUSH WITH THE FILOWUNE OF THE CURB AND GUTTER. 4 4_ THE WING AND RAMP SURFACES SHALL DE 3UDG PSI CONCRETE WITH A SIDEWALK ACCORDANCE WITH CURRENT NCDOT STAmDAAD 4 FINISH IN EDITION SPECIFICATIONS FOR ROADS AND STRUCTURES, 5. DRAINAGE STRUCTURES. MAST ARMS. LIGHT POLES AND OTHER OBSTRUCTIONS RAMP WIDTH MUST C. C SHALL NOT BE PLACED IN LINE WITH RAMPS. LOCATION OF THE RAMP SHALL TAKE PRECEDENCE OVER LOCATION OF OBSTRUCTIONS EXCEPT WHERE EXISTING MATCH SIDEWALK WIDTH (TYR) OBSTRUCTIONS ARE BEING UTILIZED IN THE NEW CONSTRUCTION. • IF TURNING SPACE PARKING TABULATION CHART (ACCESSIBLE PARKING INCLUDED) Lot or Parking Total # of Parking Spaces # of Accessible Spaces Provided Total Area Required Provided Regular with 5' Access Aisle Regular with 8' Access Aisle Accessible Provided Existing 38 127 5 1 6 Post Expansion 55 125 4 1 \ 6. SEE STANDARD DRAWING 10359 FOR DETECTABLE WARNING INSTALLATION. OBSTRUCTION DEPRESSED 2'-B' IS CONFINED BY a. Required number of parking spaces based on 'Town of Granite QuarryL, m Ordinance -Table 9.2.1. —1 CURB a GUTTER CURB OR VERTICAL q p g pg ,( O j 7. SEE USOO LNr�ECT ON DUGrx�Ms I-1 THROUGH I-3 FOR TYRcw RAMP MIN. 1 Fr. SURFACE AT BACK OF b. Existing Warehouse/Industrial - (.25 space per every 1000 sq.ft.) x (150 3 sq. ft) = 38 parking spaces required. v PLACEMENT AND INTERSECTION LAYOUTS, CONCRETE FULL DEPTH THE TURNING SPACE, rr CURB REVEAL THE DIMENSIONS OF V c. Proposed Warehouse/Industrial - .25 space per eve 1000 s .ft. x 67,250 s t 17 B. CURB RAMPS SHALL HAVE A SEGMENT OF STRAIGHT CURB AT LEAST 24 TURNING SPACE MUST p ( p p every q ) q ) INCHES LONG LOOTED ON EACH SIDE OF THE WINO SLOPE AND WfTHIN THE BE S"KY MINIMUM. CROSSWALK uARKING4. PLACEMENT FOR oesTRucTED CORNER d. 4 accessible space with 1 van access per every 76-100 parking sp ces. TURNINGS MUST MATCH; TURNING SPACE T 7� �„/ / 9. FOR ALL RAMPS AT NARKED CROSSWALKS THE RAMP OPENING AT THE FULLY DIMENSIONS MUST MATCH SIDEWALK WIDTH DIMENSIONS AND e. Off -Street Loading Requirements - (120,000 - 220,000 sf — 3�ces). 16 loading spae S' exlstmg ( RAMP WIDTH MUST '1 /1 Y DEPRESSED CURB) SHALL BE LOCATED WITHIN THE PARALLEL BOUNDARIES OF TYP. 5' X 5° MINIMUM MATCH SIDEWALK CROSSWALK MARKINGS, (4' X 4' MIN, PER PROWAG••) YY ( 1.5% (2.00% MAX) IN ANY DIRECTION WIDTH. 10_ IF A. SINGLE DIAGONAL RAMP ON A CORNER IS USED TYP. ONLY IN RETROFITS), SCE. THE ROMP CENTERLINE SHALL BE LOCATED AT THE CORNER r / /Q RADIUS CE, THE NE UNLESS OTHERWISE L E LOCATED B1' THE ENGINEER. A MIN. tiy. ,,.. • �� ELEC. 4'zi CLEAR SPACE BEYOND THE CURB FACE MUST BE WHOLLY OUTSIDE OF METER THL PARALLEL VEHICLE TRAVEL LANE (SEE OAGRAM BELOW)- . •. P 4 • • • Py`j- / CLEAR sPAGE: APPROXIMATE JURISDICTIO4 LINE BOX 4'x4` -4'X 4•MINIMUM _ _ '-`�= CLEAR -BEYOND BOTTOM GRFDE BREAK '4 P Q� SPACE -Wff IN PMESTRAN STREET CROSSING •C.+ `'•- -OUTSIDE PARALLEL VEHICLE TRAVEL LANE @ 5' CONCRETE _ RAMP (TYP.) CURBSHOWN AS _ G OPTION ONLY / RAMP WI OTH MVST M WHEN _ } suE MATCH SIDEWALK WIDTH RFAC� DEPRESSED 2'-S" PRESENT CONCRETE MIN 1 FT CURB k GUTTER (PLANTING STRIP) / Q FULL DEPTH CURB REVEAL SLOPE "A" 1-59 (2.9P9 MAx} SLOPE "B" 7.5% (8.33% MAX) SLOPE "a' Tay MAX PLACEMENT FOR SMALL CORNER RADIUS / � PROPOSED 5,620 SF NEW PAVEMENT NOT TO SCALE EXISTING LIGHT POLE TO BE RELOCATE CITY OF CHARLOTTE PLACEMENT OF CURB RAMPS / OUTSIDE OF EXPANSION FOOTPRINT. 1' LIND DEVELOPMENT STANDARDS RETAINING WALL AT OBSTRUCTED OR SMALL CORNER RADIUS / BYOTHERS� INCLUDES CHARU071E ETJ �L� 10,35A 17 ACCESSIBLE PARKING REQUIREMENTS TOTAL PARKING SPACES MINIMUM NUMBER MINIMUM NUMBER OF OF ACCESSIBLE SPACES ACCESSIBLE SPACES REQUIRED PROVIDED SPACES REQUIRED TO BE VAN ACCESSIBLE 1 TO 25 1 1 26 TO 50 2 1 51 TO 75 3 1 76 TO 100 4 1 101 TO 150 5 1 151 TO 200 6 1 201 TO 300 7 1 301 TO 400 8 1 401 TO 500 9 2 501 TO 1000 2% OF TOTAL 1 IN EVERY 8 ACCESSIBLE SPACES 1001 AND OVER 20 PLUS 1 FOR 1 IN EVERY 8 EACH 100 OVER 1000 ACCESSIBLE SPACES SECTION 4.1.2 (5) OF THE AMERICANS WITH DISABILITIES ACT (AEA). SEE 4.1,2,(5) (d) FOR MEDICAL CARE FACILITIES 8' 8' 8' 5' 8' EXISTING HYDRANT EXISTING DUMPSTER LOCATION TO REMAIN PENALTY $ 250 I SEE STANDARD NO. 50.1OC FOR SUPPLEMETAL SIGN DETAIL LEGEND ' S 63° 07 > SUBJECT PROPERTY:BOU DARY S2�, EXISTING SANITARY P. / EASMENT F , EXISTING 68': DUKE :POW . R/W —"'—"'—"'— EXISTING 50'// DUK POW EASMENT ADJACENT P/ROPEY XX EXISTING FWCE PROPOSED UILID G E F�ANSION PROPOSED:FENCE 11 W W W W EXISTING ATER INE PROPOSE WATO LIN GRAPHIC SCALE 1 60 0 30 60 120 ' o � ' COPYRIGHT© 2019, AMICUS PARTNERS, PLLC. /01 ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS ADJACENT PROPERTIES REFERENCED FROM A SURVEY CONDUCTED BY SOUTHPOINT DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT SURVEYING. OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VAUD, TRUE COPIES. PROPOSEDEO EXISTING 8" FIR PROTECTION L00 :: F. FLOOR =819.76' �A 3 ` ^ UTILI BOXE PVMT PROPOSED PASE I DEVELOPMENT SUMMARY PROJECT NAME: BUILDING EXPANSION FOR 1735 HEILIG ROAD \ OWNER: IOM ENTERPRISES, LLC PARCEL P.I.N.: 402 021 CIVIL SITE DESIGN PLANS PREPARED BY: AMICUS PARTNERS, PLLC PHONE: 704-573- 1 G2 1 ZONING: LI / CBI JURISDICTION: CITY OF GRANITE QUARRY/ROWAN COUNTY APPROXIMA7 EXISTINGO� P 18WATER M �` SETBACK (EAST): 10 FT (NORTH): 25 FT Firm License # P-1191 • (SOUTH): 30 FT (WEST): 10 FT 7140 Weddinton Road Suite 140 s LOT SIZE: 1, 159, 13 1 .G12G.G I SQ. FT/ACRES Concord, NC 28027 EXISTING USE: MANUFACTURING AND WAREHOUSE Civil Site Design Low Impact Development \� � PROPOSED USE: MANUFACTURING AND WAREHOUSE \Cpr Small —Scale Building Design SIC NUMERIC CODE: 1541 Telephone: 704.573.1621 \ !� EXISTING PARKING: 1 29 SPACES Facsimile: 704.248.7951 \\ `� EXISTING HANDICAP PARKING: G SPACES \ P AREA OF EXISTING BUILDING COVERAGE: 150,13 I SQ.FT Seals: \\ AREA OF EXISTING PARKING AND DRIVE COVERAGE: 1 80,42G SQ.FT c 4� \ \ v AREA OF EXISTING SIDEWALK COVERAGE: 2,73G SQ.FT �� o o .,• y EXISTING \ ` �� P '9 ��.`� : �•Fessi by% HYDRAN� ' TOTAL EXISTING IMPERVIOUS AREA: 333,293 SQ.FT SEAL AREA OF PROPOSED BUILDING ADDITION. G7,500 SQ.FT 0 032006 \ O s� rx \ �s� AREA OF ADDITIONAL PARKING AND DRIVE COVERAGE: 32,24G SQ.FT o�R .. •PP���O`, AREA OF IMPS VIOUS TO BEREMOVED: 34,009 S .FT �''•. .•`'� �aunu�� �04j TOTAL PROPOSED NEW IMPERVIOUS AREA: 99,74G SQ.FT 03-12-2019 \1 NET INCREASE IN IMPERVIOUS AREA: G5 G87 SQ.FT 'S� PERCENT IMPERVIOUS AREA: 34.42% \ O O QAO AC IBLE SIGNAGE�0A \ s (SEE DETAILPROITE�CT ONE L OE , ��� 1',ZCI STI N� \ H RAN \ TB M ° O TER H Fs PR9K0SED ENTRANCE GATE -\ /EL .=815.28' UJ fs '� C. TO C ORDINATE INSTALLATION tic O O)e`BOX WITH ROWAN COUNTY FIRE MARSHALL F. FLOOR F 4' SO Off, o g `O�P�S +s O�o 1 o (j F E Al .o Q \ A. QD ISTING EXISTING 8" FIRE MAIN T t.'°' '. HYDR BE ABANDONED EXISTING f W HYDRANT PROPOSED ENTRANCE GATE 3o PG.C. TO COORDINATE INSTALLATION �R OF K OX BOX WITH ROWAN COUNTY Fq� FIRE MARSHALL 'SFTeq �cr i'� EXIST HYDR T� T v G 0 XISTING 8" FIRE 80.0 � L PROTECTIOt6DOP 4 T PROPOSED 26,626 SF CONCRETE DRIVEW XISTING LIGHT PO TO BE RELOCATED W OUTSIDE OF EANSION FOOTPRINT. P' \\ •. o . 00 L0 \ XISTING FIRE HYDRANT TO BE LOCATED ~ OUTSIDE OF EXPANSION FOO-�,PRINT. N G.C. TO VERIFY FIRE LINE LOCATION / V PRIOR TO FOUNDATION CONSTRUCTI N ,—EX TING FIRE MAIN PEE. TO BE RELO AT D EX. SEE. ROPOSED 8" PVC WATER LINE POND °h TO SERVE SPRINKLER SYSTEM / \ \ / tK XISTING LIGHT POLE TO BE RELOCATED \ \ OUTSIDE OF EXPANSION FOOTPRINT. / 7 7\ ROPOSED 8" PVC FIRE MAIN < �17 ��. ACCESS ROAD TYPICAL CROSS-SECTION VTOP OF POND ROUGHED IN PROP. BUILDING EXPANSION STING FIRE HYDRANT TO BE RELOCATED OUTSIDE OF EXPANSION FOOTPRINT. G.C. TO VERIFY FIRE LINE LOCATION PRIOR TO FOUNDATION CONSTRUCTION ED FENCE - ---- 1 /FT KEY 0 6" CONCRETE 6" STONE PROP. UNPAVED \ SHOULDER \ z 4-. x � U C Project Number: Date: Drawn ,By: , Checked By:, 17-18-092 6 03/ 1 2/20 1 9 JRD, NRl' Revisions: 07-2G- 18 ORIGINAL SUBMITTAL 10-23-18 PER DEVELOPER 1 2-1 G- 18 FER Towle of GRANITE QUARRY O I - 14- 19 ffR TOWN of GRANITE QUARRY 02-1 3- 1 9 1 FER CITY of 5Au5BURY 03-1 2- 1 9 FER CITY of SAusBURY Sheet Title: SITE PLAN \ \3 Sheet No: �1 SALISBURY-ROWAN ULITIES STANDARDS AND SPECIFICATIONS SECTION II - MATERIALS 2.01 DUCTILE IRON PIPE (DIP) ALL DUCTILE IRON PIPE SHALL BE PRESSURE CLASS 350 (SEE CURRENT CITY OF SALISBURY WATER & SEWER APPROVED PRODUCT MANUFACTURER'S SHEET FOR APPROVED TYPES LOCATED IN APPENDIX "A") DIP PIPE MUST BE MANUFACTURED IN THE USA. DIP PIPE MUST BE NEW PIPE (NO USED PIPE ALLOWED). NO DAMAGED PIPE WILL BE ALLOWED. ALL WATER PIPE SHALL HAVE A POTABLE WATER LOGO (PW) ON ALL JOINTS. THE DUCTILE IRON PIPE SHALL BE MANUFACTURED IN ACCORDANCE WITH ALL APPLICABLE REQUIREMENTS OF AWWA STANDARD C-151/ANSI A21.51, AWWA C-111/ANSI A21.11, AWWA C-150/ANSI A21.50. THE DUCTILE IRON PIPE SHALL BE SUPPLIED IN NOMINAL LENGTHS OF 18 OR 20 FEET. THE DUCTILE IRON PIPE SHALL BE CEMENT -MORTAR LINED WITH A SEALCOAT IN ACCORDANCE WITH AWWA C-104, AND BITUMINOUS COATED ON THE EXTERIOR IN ACCORDANCE WITH AWWA C-151. PIPE JOINTS SHALL BE MECHANICAL OR "PUSH -ON" MANUFACTURED IN ACCORDANCE WITH AWWA STANDARD C-111, OR FLANGED JOINTS IN ACCORDANCE WITH AWWA STANDARD C-115. EACH JOINT OF DUCTILE IRON PIPE SHALL BE HYDROSTATICALLY TESTED TO 500 PSI AT THE POINT OF MANUFACTURE BEFORE THE OUTSIDE COATING AND INSIDE LINING ARE APPLIED. TESTING MAY BE PERFORMED PRIOR TO MACHINING BELL AND SPIGOT. FAILURE OF DUCTILE IRON PIPE SHALL BE DEFINED AS ANY RUPTURE OR LEAKAGE OF THE PIPE WALL. ALL MATERIALS USED IN THE PRODUCTION OF THE PIPE ARE TO BE TESTED IN ACCORDANCE WITH AWWA STANDARD C-151 FOR THEIR ADEQUACY WITHIN THE DESIGN OF THE PIPE, AND CERTIFIED TEST RESULTS ARE TO BE PROVIDED TO THE CITY UPON REQUEST. ALL CERTIFIED TESTS, HYDROSTATIC AND MATERIAL, ARE TO BE PERFORMED BY AN INDEPENDENT TESTING LABORATORY AT THE EXPENSE OF THE PIPE MANUFACTURER. RESTRAINED JOINTS SHALL BE TR FLEX OR LOK TYTE AS MANUFACTURED BY U.S. PIPE, LOK-FAST OR LOK-RING AS MANUFACTURED BY AMERICAN PIPE OR APPROVED EQUAL. RESTRAINED JOINTS SHALL BE USED WHEN THE PIPE LOCATION EXCLUDES THE USE OF THRUST BLOCKS FOR PROPER SUPPORT. 2.02 DUCTILE IRON FITTINGS DUCTILE IRON FITTINGS MUST BE USA MADE (SEE CURRENT CITY OF SALISBURY WATER & SEWER APPROVED PRODUCT MANUFACTURER'S SHEET FOR APPROVED TYPES LOCATED IN APPENDIX "A") ALL FITTINGS SHALL BE SHORT, COMPACT DUCTILE IRON TYPE, PRESSURE CLASS 350 IN ACCORDANCE WITH ANSI/AWWA C153/A21.53, AWWA C-11 VANSI A21.11, AWWA C-104/ANSI A21.4. THE FITTINGS SHALL BE TESTED, AND THE MANUFACTURER SHALL PROVIDE CERTIFIED TEST RESULTS WHEN REQUESTED BY THE CITY. THIS TESTING SHALL INCLUDE HYDROSTATIC PROOF TESTING OF THE FITTINGS. ALL FITTINGS SHALL BE ALL -BELL AND OF THE MECHANICAL JOINT TYPE. MECHANICAL JOINTS SHALL BE MANUFACTURED IN ACCORDANCE WITH AWWA STANDARD C-1 11 /A21.1 1. ALL FITTINGS SHALL BE DUCTILE IRON AND SHALL HAVE A MINIMUM WORKING PRESSURE RATING OF 350 PSI AND A MINIMUM IRON STRENGTH OF 25,000 PSI. ALL FITTING INTERIORS SHALL BE CEMENT -MORTAR LINED AND SEALED IN ACCORDANCE WITH AWWA STANDARD C-104/A21.4, AND THE OUTSIDE SHALL BE BITUMINOUS COATED. 2.03 POLYVINYL CHLORIDE PIPE (PVC) AND FITTINGS ALL PVC WATER PIPE IS TO BE IN ACCORDANCE WITH AWWA C-900. PIPE SHALL HAVE PUSH -ON JOINTS WITH INTEGRAL BELL AND LOCKED -IN GASKET AND SHALL CONFORM TO ASTM D-1784, ASTM D-3139. THE BELL SHALL CONSIST OF AN INTEGRAL WALL SECTION WITH A LOCKED -IN, SOLID CROSS-SECTION ELASTOMERIC RING. PIPE WILL ALSO BE THE TYPE APPROVED BY THE NATIONAL SANITATION FOUNDATION, AND SHALL BEAR THE NSF LOGO. ALL WATER PIPE SHALL HAVE A POTABLE WATER LOGO (PW) ON ALL JOINTS. (SEE CURRENT CITY OF SALISBURY WATER & SEWER APPROVED PRODUCT MANUFACTURER'S SHEET FOR APPROVED TYPES LOCATED IN APPENDIX "A") ALL PIPE FOR 6-INCH AND LARGER MAINS SHALL CONFORM TO AWWA STANDARD C900, DR 14, CLASS 200, RATED WITH A WORKING PRESSURE 200 PSI. ALL FITTINGS SHALL BE MECHANICAL JOINT DUCTILE IRON AS SPECIFIED IN ITEM 2.02 OF THIS SECTION. PVC PIPE WILL BE USED ONLY IN AREAS WHERE THE HIGHEST WORKING PRESSURE IS 125 PSI OR LESS. MAXIMUM LINE SIZE FOR PVC PIPE IS 8-INCHES. MINIMUM COVER IS 3-FEET. DUCTILE IRON PIPE WILL BE REQUIRED IN ALL LOCATIONS WHERE THE WORKING PRESSURE EXCEEDS 125 PSI AS MEASURED OR CALCULATED, WHERE COVER IS LESS THAN 3-FEET OR WHERE PIPE SIZE EXCEEDS 8-INCHES. PVC PIPE SHALL NOT BE USED UNDER ROADS, FOR ROAD CROSSINGS, CREEK CROSSINGS, OR RAILROAD CROSSINGS. PVC PIPE THAT HAS BEEN YARD STORED FOR AN EXTENDED TIME AND/OR EXPOSED TO OUTSIDE WEATHER ELEMENTS FOR A EXTENDED AMOUNT OF TIME (TO THE POINT THAT IT HAS CHANGED COLOR AND/OR HAS BECOME BRITTLE) SHALL NOT BE ALLOWED. ALL PIPES AND MATERIALS ARE TO BE TESTED ACCORDING TO THE REQUIREMENTS OF AWWA STANDARD C-900. CERTIFIED TEST RESULTS ARE TO BE PROVIDED TO THE CITY WHEN REQUESTED. THESE TESTS SHALL BE PERFORMED BY AN INDEPENDENT TESTING LABORATORY AT THE EXPENSE OF THE PIPE MANUFACTURER. PVC PIPE SHALL BE INSTALLED WITH STONE BEDDING AS SHOWN IN THE STANDARD DETAILS AS TYPE II BEDDING, UNLESS ROCK, POOR SOIL OR SATURATED CONDITIONS EXIST, IN WHICH CASE, TYPE III BEDDING SHALL BE USED. PVC PIPE FOR WATER LINES SHALL HAVE COPPER TRACER WIRE (14-GAUGE) FOR ITS ENTIRE LENGTH AND SHALL BE LOOPED UP AT VALVE BOXES FOR CONNECTION TO PIPE LOCATING EQUIPMENT. 2.05 GATE VALVES AND TAPPING VALVES GATE VALVES AND TAPPING VALVES: (SEE CURRENT CITY OF SALISBURY WATER & SEWER APPROVED PRODUCT MANUFACTURER'S SHEET FOR APPROVED TYPES LOCATED IN APPENDIX "A") GATE VALVES TWELVE (12) INCHES IN DIAMETER AND SMALLER, SHALL BE ALL BELL WITH MECHANICAL TYPE JOINTS. THEY SHALL BE "O" RING, OPEN -LEFT VALVES OF THE NONRISING STEM TYPE. VALVES SHALL BE AWWA TYPE. RESILIENT SEATED VALVES MAY BE USED ON ALL NEW CONSTRUCTION. ON EXISTING WATER LINES, VALVES SHALL BE WEDGE (BRONZE) SEATED. VALVES SHALL BE DESIGNED FOR A MINIMUM OF 200 PSI WORKING PRESSURE AND 300 PSI HYDROSTATIC TEST PRESSURE WITH A TWO (2) INCH OPERATING NUT. VALVES SHALL BE CAST IRON OR DUCTILE IRON. ALL INTERIOR AND EXTERIOR PARTS SHALL BE EPDXY COATED. VALVES SHALL BE M.J. TYPE, WITH SLOTTED HOLES ALLOWED ONLY AT THE 11 O'CLOCKAND 1 O'CLOCK POSITIONS. SHOULDER BOLTS (NOT TEE BOLTS) SHALL BE USED IN THE SLOTTED HOLES. FLANGE VALVES CAN NOT BE SUBSTITUTED FOR TAPPING VALVES. 2.08 VALVE BOXES ADJUSTABLE VALVE BOXES SHALL BE GRAY CAST IRON OF THE DIMENSIONS SPECIFIED IN THE STANDARD DETAILS OF THESE SPECIFICATIONS. BOXES AND EXTENSIONS SHALL BE OF THE "SLIP-ON" TYPE. SCREWED CONNECTIONS SHALL NOT BE ACCEPTED. THE WORD "WATER" SHALL BE CAST INTO THE LID (SEE CURRENT CITY OF SALISBURY WATER & SEWER APPROVED PRODUCT MANUFACTURER'S SHEET FOR APPROVED TYPES LOCATED IN APPENDIX "A") 2.09 FIRE HYDRANTS NOZZLES SHALL HAVE NST THREADS AND SHALL CONSIST OF THE FOLLOWING: 2-TWO AND ONE-HALF INCH NOZZLES, AND 1-FOUR AND ONE-HALF INCH NOZZLE. ALL NOZZLES SHALL BE PROVIDED WITH CAP AND CAP RETAINING CHAIN. THE HYDRANT VALVE OPENING SHALL BE FOUR AND ONE-HALF INCHES. BRONZE TO BRONZE THREADS SHALL BE PROVIDED BETWEEN THE HYDRANT SEAT OR SEAT RING AND THE SEAT ATTACHING ASSEMBLY. ALL HYDRANTS MUST INCLUDE CAST OR DUCTILE IRON EPDXY LINED SHOE AND PROTECTIVE VALVE STOP DEVICE. ALL HYDRANTS SHALL BE GREASE LUBRICATED, NO OIL FILLED ASSEMBLIES SHALL BE ALLOWED. FIRE HYDRANT COLOR SHALL BE SILVER OR COLOR REQUIRED BY THE LOCAL FIRE AUTHORITY HAVING JURISDICTION. (SEE CURRENT CITY OF SALISBURY WATER & SEWER APPROVED PRODUCT MANUFACTURER'S SHEET FOR APPROVED TYPES LOCATED IN APPENDIX "A"). HYDRANTS SHALL BE OPEN -LEFT TYPE AND SHALL HAVE A SIX-INCH HUB -END OR MECHANICAL JOINT ELBOW. THE HYDRANT BARREL SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM OF THREE FEET BURY AND BE OF THE BREAK -AWAY IMPACT TYPE. HYDRANT TEES WITH SCREWED END VALVE ASSEMBLIES, AS MANUFACTURED BY GRIFFIN OR EQUAL ARE ACCEPTABLE, OR RESTRAINT MAY BE ACCOMPLISHED USING 3/4" BARS AS SHOWN IN THE STANDARD DETAILS. COPYRIGHT© 2019, AMICUS PARTNERS, PLLC. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS ADJACENT PROPERTIES REFERENCED FROM A SURVEY CONDUCTED BY SOUTHPOINT DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT SURVEYING. OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VAUD, TRUE COPIES. SECTION III - CONSTRUCTION METHODS PART 1 -SITE WORK GENERAL PIPE LAYING SHALL IN ALL INSTANCES BE ACCOMPLISHED IN A WORKMANLIKE MANNER LAID TRUE TO LINE AND GRADE WITH BELL ENDS FACING (UP -GRADE) IN THE DIRECTION OF LAYING. THE VARIOUS PIPES SHALL BE HANDLED, BELLED -UP AND LAID IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS AND GOOD ENGINEERING PRACTICES. JOINT DEFLECTIONS SHALL NOT EXCEED 75% OF THE MANUFACTURER'S RECOMMENDED MAXIMUM DEFLECTION. (b) TYPE II -GRANULAR MATERIAL EMBEDMENT: FOR TYPE II BEDDING, THE TRENCH BOTTOM IS UNDERCUT A MINIMUM OF SIX (6- INCHES BELOW THE PIPE BARREL GRADE AND FILLED WITH AN NO. 67 STONE AND BACKFILLED WITH CLEAN BACKFILL AS SHOWN IN THE STANDARD DETAIL, PLACED IN 6-INCH LOOSE LAYERS AND COMPACTED TO 95%. 1.06 INSTALLATION LIMITATIONS THE FOLLOWING ARE LIMITATIONS AND BEDDING REQUIREMENTS FOR SUPPORTIVE STRENGTH AND SHALL BE ADHERED TO AT ALL TIMES. (b) TYPE II BEDDING, OR GREATER, SHALL BE USED FOR ALL PVC WATER PIPE, UNLESS CONDITIONS OF POOR (SATURATED) SOIL OR ROCK ARE PRESENT. SECTION IV - TESTS AND INSPECTIONS PART 2 -WATER BACKFILL SHALL BE TESTED BY AN INDEPENDENT TESTING LABORATORY APPROVED BY THE CITY. TESTS SHALL BE PERFORMED IN ACCORDANCE WITH ASTM METHODS AND BE APPROPRIATE TO THE SOIL TYPE. THE BACKFILL IN PIPELINE TRENCHES SHALL BE TESTED AT A MINIMUM AS FOLLOWS: PIPELINES WITHIN THE ROAD RIGHT-OF-WAY, EXISTING OR PROPOSED ROADS. TEST DENSITY EVERY 12-INCHES (2 LIFTS) OF PLACED BACKFILL AT INTERVALS OF 200 FEET, MINIMUM ONE PER DAY. PIPELINE UNDER LAWNS OR CROSS-COUNTRY: TEST DENSITY EVERY 12-INCHES (2 LIFTS) OF PLACED BACKFILL AT INTERVALS OF 500 FEET, MINIMUM ONE PER DAY. AT COMPLETION OF WORK, LINES SHALL BE THOROUGHLY CLEANED BY FLUSHING POTABLE WATER TO REMOVE ALL DIRT AND DEBRIS. PIPELINE SHALL BE FLUSHED AT A RATE OF AT LEAST 2.5 FEET PER SECOND FOR A DURATION SUITABLE TO THE UTILITIES INSPECTOR. WATER THAT IS USED FOR FLUSHING (WATER LINES) THAT HAS NOT BEEN TREATED (CHLORINATED) BY THE CONTRACTOR MAY BE DISCHARGED INTO THE STORM DRAIN. 2.03 LEAKAGE TEST THE WATER LINE SHALL BE TESTED FOR LEAKAGE. THE WATER LEAKAGE TEST IS A TWO PART TEST; PART A (PRESSURE AND PART B ALLOWABLE LEAKAGE. PART A & PART B MUST PASS FOR THE TEST TO BE CONSIDERED SUCCESSFUL. LEAKAGE TESTS SHALL BE CONDUCTED ON A SCHEDULE AGREED UPON BY THE UTILITIES INSPECTOR, ENGINEER OR ENGINEER'S REPRESENTATIVE AND THE CONTRACTOR. CITY INSPECTION IS REQUIRED DURING THE TESTS WITH A MINIMUM 48 HOUR NOTICE (2 BUSINESS DAYS). WATER SERVICES (TAP, SERVICE LINE, AND METER SETTER) SHALL BE INSTALLED PRIOR TO WATER LINE LEAKAGE TEST. THE PIPE SHALL BE FILLED WITH POTABLE WATER FOR A PERIOD OF 24 HOURS BEFORE TESTING BEGINS. IT SHALL BE ENSURED THAT THE PIPE IS FULL OF WATER AND ALL AIR HAS BEEN REMOVED BEFORE TESTING. CONTRACTOR SHALL PRETEST THE WATER LINE PRIOR TO SCHEDULING A TEST WITH ENGINEER AND UTILITIES INSPECTOR. THE WATER LINE SHALL BE TESTED AT 1.25 TIMES THE HIGHEST WORKING PRESSURE ALONG THE SECTION, OR 200 PSIG, WHICHEVER IS GREATER. THE TEST SHALL BE OF AT LEAST 2 HOURS DURATION AND THE PRESSURE MAY NOT DROP MORE THAN 5 PSIG DURING THE TEST. ALL EXPOSED PIPE, FITTINGS, VALVES AND HYDRANTS SHALL BE VISUALLY EXAMINED DURING THE TEST. LEAKAGE SHALL BE NO GREATER THAN THE AMOUNT DETERMINED BY THE FORMULA: L = SD (P)112 133,200 WHERE L = ALLOWABLE LEAKAGE (GALLONS / HOUR) S = LENGTH OF PIPE IN TEST (FEET) D = NOMINAL PIPE DIAMETER (INCHES) P = AVERAGE TEST PRESSURE (PSIG) PIPE HAVING MORE THAN ALLOWED LEAKAGE SHALL BE REPAIRED. ALL VISIBLE LEAKS SHALL BE REPAIRED REGARDLESS OF THE AMOUNT OF LEAKAGE. 2.04 VALVES VALVES SHALL BE FIELD TESTED AS DIRECTED BY AWWA SPECIFICATION C500 AND C504 AS APPLICABLE. (a) DURING THE LAST STAGES OF THE TEST AND WITHOUT ANY REDUCTION IN PRESSURE, FIRST THE HYDRANT VALVES WILL BE CLOSED, THEN PROGRESSING IN AN ORDERLY MANNER FROM THE END OPPOSITE FROM THE TEST PUMP, EACH MAIN LINE VALVE WILL BE CLOSED AND PRESSURE RELEASED TO DETERMINE IF IT IS HOLDING PRESSURE (MINIMUM 30 MINUTES). (b) ALL BUTTERFLY VALVES WILL BE TESTED TO 150 PSI (OR 1.25 TIMES SYSTEM PRESSURE, IF HIGHER) FOR A MINIMUM OF 30 MINUTES (EACH) AFTER THE PIPELINE HAS BEEN SUCCESSFULLY TESTED. VALVES SHALL BE TESTED ON A SCHEDULE AGREED UPON BY THE UTILITIES INSPECTOR AND THE CONTRACTOR. CITY INSPECTION IS REQUIRED DURING THE TESTS. 2.05 STERILIZATION SAMPLING TAPS SHALL BE PROVIDED EVERY 1,000 FEET AND AT THE END OF EACH BRANCH. TAPS SHALL BE LOCATED AND CONSTRUCTED SO SAMPLES MAY BE EASILY COLLECTED WITHOUT DANGER TO PERSONNEL OR LIKELIHOOD OF SAMPLE CONTAMINATION. SAMPLING TAPS MAY BE USED AS BLOW -OFFS. THE NUMBER AND LOCATION OF THE TAPS/BLOW-OFFS MUST BE APPROVED BY THE UTILITIES INSPECTOR. HYDRANTS MAY NOT BE USED FOR BACTERIOLOGICAL SAMPLING. ALL PARTS OF A POTABLE WATER SYSTEM (INCLUDING SERVICE LINES) SHALL BE STERILIZED IN ACCORDANCE WITH AWWA C601 AND THESE SPECIFICATIONS. PREVENTIVE AND CORRECTIVE MEASURES DURING CONSTRUCTION (AWWA C601) SHOULD BE ADHERED TO DURING CONSTRUCTION TO ENSURE SUCCESS OF THE STERILIZATION PROCESS. LINES SHALL BE INITIALLY CHLORINATED TO 100 MG/L. LINES MUST HAVE A MINIMUM FREE CHLORINE RESIDUAL OF 24 MG/L AFTER 24 HOURS. WHEN THE CONTRACTOR HAS DETERMINED THAT THE LINE HAS BEEN CHLORINATED TO THE PROPER LEVEL, HE SHALL REQUEST A LABORATORY CONFIRMATION OF THE FREE CHLORINE LEVEL. ADVANCE NOTICE SHALL BE GIVEN TO THE UTILITIES INSPECTOR PRIOR TO REQUESTING SAMPLING FOR CHLORINE LEVEL CONCENTRATION (ON SITE TEST) AS REQUIRED IN SECTION 1.80 - INSPECTION. IN LIEU OF USING CITY RESOURCES, THE CONTRACTOR MAY USE AN APPROVED CERTIFIED TESTING LAB; HOWEVER CITY INSPECTION OF THE TEST IS REQUIRED. AFTER THE REQUIRED CONTACT TIME (24 HOURS), THE CONTRACTOR SHALL HAVE THE CHLORINE RESIDUAL TESTED AND IF THE CHLORINE LEVELS ARE AT LEAST 24 MG/L THEN THE CONTRACTOR CAN FLUSH THE LINE AND ALL APPURTENANCES WITH SALISBURY DISTRIBUTION WATER UNTIL COMPLETELY PURGED. NO BACTERIOLOGICAL SAMPLES WILL BE COLLECTED AT POINTS WHERE THE FREE CHLORINE RESIDUAL EXCEEDS THE AMBIENT DISTRIBUTION SYSTEM FREE RESIDUAL BY MORE THAN 0.5 MG/L. CARE MUST BE TAKEN TO DISCHARGE THE CHLORINATED WATER IN A MANNER WHICH WILL NOT ENDANGER PLANT OR ANIMAL LIFE OR BE UNSAFE. CHLORINATED WATER MUST BE DISCHARGED IN AN ENVIRONMENTALLY SAFE MANNER AND IN ACCORDANCE WITH ALL FEDERAL, STATE, AND/OR LOCAL LAWS AND REGULATIONS. CHLORINATED STERILIZATION WATER SHALL NOT BE DISCHARGED INTO THE CITY'S SEWER OR STORM DRAIN SYSTEMS. CONTRACTOR MUST TREAT THE CHLORINATED WATER TO MEET NORTH CAROLINA QUALITY DISCHARGE STANDARDS. BACTERIOLOGICAL TESTING/SAMPLING SHALL BE REQUESTED ON THE SAME DAY THE LINE IS FLUSHED. BACTERIOLOGICAL TESTING WILL BE PERFORMED BY THE CITY LABORATORY MONDAY THROUGH THURSDAY PRIOR TO 12:00 P.M. AT LEAST 24 HOUR NOTICE SHALL BE GIVEN THE UTILITIES INSPECTOR/LAB PRIOR TO SAMPLING. THE UTILITIES INSPECTOR WILL COLLECT AND DELIVER THE SAMPLES TO THE LAB (TESTING FEE APPLIES). EACH SAMPLE SHALL BE MARKED LEGIBLY, IDENTIFYING WITH LETTERS OR NUMBERS EACH SAMPLING POINT. UNDISTURBED EARTH 12' , CLASS A 3000 PS] 3o CONCRETE x ti rV N FOR DESIGN PRESSURE-200 PSI TYPICAL SECTION SIZE SCHEDULE TEE OR BEND CLASS A u z Iri? L ire L 74aa PS] CLASS A Uaaa PS] ! d E CONCRETE CONCRETE UNDISTURBED UNDISTURBED n,••''''''''': EARTH EARTHF♦ ♦�,' UNDISTURBED •. EARTH PLAN - TEE PLAN I - BEND C174 OF SALISBURY, N.C. STANDARD 3E7A]L DATE; JANUAR" 1, 1991 WATER SYSTEMS N07 To SCALE THRUST BL❑CKING STANDARD W-1 CONCRETE �NRUST BLOCK SCHEDULE P] PE EE ND S]IE 9p fTEE� �5? 22?? lI" INCHES N L N L N L N L 2' 75' 1,5` ,50' 1,0' ,50' ,75' .50' .50' 4' 1.5` 3.0' I.0' �,5' 1A' 1.5` I.4' 1.4' �" �.4' a.a• 1.s• 3s• I.a• 3.a� I.4• I.s' s' s.s' s.a` �.s� a.a` 1.s` s.s` 1.a' �.5• i0' 3.0' 6.5' Z.5' S.0' 2.0' 4.0' l.a' 3.a' 72' 3,5' 8.0' 3.0' 5.0' 2.5' S.0' ].5` 3.5` 9" 7 5/8' 6 3/8' 2' A w WATER > 6 1/8° 6 1/2' A 9 1/2' w 5 3/4' �w i� 7 5/16' �l 5 1/4' N 5 3/4' �u _ 7' `° SECTI❑N A -A 8" 8 1/2' NOTE: 10 1/4' SEE CURRENT APPROVED PRODUCT MANUFACTURERS SHEET FOR APPROVED TYPES (APPENDIX A) CITY OF SALISBURY, N.C, STANDARD DETAIL DATE: OCTOBER 17, 2006 WATER SYSTEMS NOT TO SCALE VALVE BOX STANDARD W-4 VARIES VARIES SEE NOTE #2 AS DIRECTED AS DIRECTED PUMPER NOZZLE TO FACE STREET AT 90° 18"x18'x6' DEEP CONCRETE PAD - oD VALVE BOX 112 CU. N SEE DETAIL z No 67 STONE DUCTILE IRON M.J. W-4 � TEE W/6BRANCH OR 'HYDRANT TEE 6° GATE VALVE 6" DI PIPE e I MIN, PR❑VIDE RETAINER GLAND FOR EACH MECHANICAL JOINT FITTING (TEE, VALVE, BEND) T- BOLTS Ql RETAINER GLAND (MEGA -LUGS OR GRIP PIPE RINGS ONLY) FOR DUCTILE IRON PIPE Q Q2 SEE CURRENT APPROVED PRODUCT MANUFACTURERS SHEET FOR APPROVED TYPES (APPENDIX "A') CITY OF SALISBURY, N.C. STANDARD DETAIL DATE. OCTOBER 17, 2006 AMENDED; MAY 19, 2009 WATER SYSTEMS NOT TO SCALE STANDARD W-3 FIRE HYDRANT PAVEMENT BRICKS 18'x 18'x6�. ,OVER CON(. PAD STANDARD VALVE BOk ,`aLVE Dok NOT To cONTAET TOP SECT]OhI WATER MAIN OR VALVE . TAMPED SACKF[LL� OR -: OTHER soon SUPPORT . USE: UNDER BOk ADDITIONAL VALVE BOkES FOR EXTENSIONSf i. SLIP-ON SOIL PIPE GASKET �-STANDARD VALVE Box BOTTOM SECTION rv7rn117,7nn1 VALVE BOk COVER WATER I xix _ VALVE $' OE MASHED STONE-/ TAMPED BACKFILL INSTALLATION CITY OF 5AL]SBUR'+, N.L. STANDARD DETAIL DATE JANUARY 1, ]99] WATER SYSTEMS Nor TO SCALE VALVE BOX INSTALLATI❑N STANDARD w-5 TOP 6' - 100% STANDARD PROCTOR /j SLOPE OR SHORING PER OSHA, COMPACTED BACKFILL -IN 6" LAYERS, 95% STANDARD PROCTOR, iu z CLEAN BACKFILL � WO MATERIAL LARGER THAN 2°) AGGREGATE N0, 67 � BEDDING-1/4 PIPE D.D. BELOW PIPE (MIN, 6°) AND 6" UP TO PIPE MIDPOINT MIN, "TYPE II" 12" MIN, NOTES 1, FOR USE WITH ALL PVC WATER PIPE, UNLESS CONDITIONS OF POOR OR SATURATED SOIL OR ROCK ARE PRESENT, 2, TRENCH SIDE SLOPES SHALL BE IN ACCORDANCE WITH OSHA REQUIREMENTS, SUPPORT OR SHORE WHEN TRENCH IS MORE THAN 5' DEEP AND 8' LONG, BEGIN SIDE SLOPE, IF USED, APPROX, 18" ABOVE TOP OF PIPE, 3, BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER THE PIPE IS LAIDCOMPACTION REQUIREMENTS SHALL BE ATTAINED BY THE USE OF MECHANICAL TAMPS ONLY, EACH AND EVERY LAYER OF BACKFILL SHALL BE PLACED LOOSE IN 6' LAYERS AND THOROUGHLY COMPACTED INTO PLACE, 4, UNDER NO CIRCUMSTANCES SHALL WATER BE PERMITTED TO RISE IN UNBACKFILLED TRENCHES AFTER THE PIPE HAS BEEN PLACED, 5, ALL MATERIAL SHALL HAVE AN IN PLACE DENSITY OF 100% TO A DEPTH 6° BELOW THE FINISHED GRADE OF THE BACKFILL MATERIAL, AND 957 AT GREATER THAN 6° BELOW GRADE, CITY OF SALISBURY, N.C. STANDARD DETAIL DATE; JANUARY 1, 1991 PIPELINE INSTALLATION NOT TO SCALE TYPE II BEDDING STANDARD P-2 Firm License # P-1191 7140 Weddinton Road Suite 140 Concord, NC 28027 Civil Site Design Low Impact Development Small -Scale Building Design Telephone: 704.573.1621 Facsimile: 704.248.7951 Seals: �1P pFE3S/ON,•�-9 SEAL 032006 �i•••••F/VGINE��.•• �Q- �i�_ a�A S • R. 03-12-2019 Protect Number: 17-18-092 Date: 03- 12-20 19 Drawn ,By: , JRD, Checked By: NRP Re -visions: 03- 12- 19 PER CITY OF SALISBURY Sheet UTILITY NOTES & DETAILS Sheet No: C-2.1 . 50' DUKE POWER ESM- (D.B. 782 PG. 904)\ NOTE: All Existing Landscaping to remain —X I I' SUBJECT PROPERTY BOUNDARY II EXISTING SANITARY SEWER EASMENT EXISTING 68' DUKE POWER R/W I EXISTING 50' DUKE POWER EASMENT ADJACENT PROPERTY EXISTING FENCE i I PROPOSED BUILDING EXPANSION PROPOSED FENCE 1 ' / 60 0 30 60 120 I LEGEND I GRAPHIC SCALE COPYRIGHT © 2019, AMICUS PARTNERS, PLLC ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VALID, TRUE COPIES. ' I I 1 REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND ADJACENT PROPERTIES REFERENCED FROM A SURVEY CONDUCTED BY SOUTHPOINT SURVEYING. . "I \ Firm License # P-1191 7140 Weddinton Road Suite 140 Concord, NC 28027 Civil Site Design Low Impact Development Small —Scale Building Design Telephone: 704.573.1621 Facsimile: 704.248.7951 Seals: N CAR ° Q SEAL r _z> 032006 ti0�°q �111111111\ 01-14— 2019 z \ o < \ \ z 0' SHADE \ \ \ Froject Number: 17-18-092 \ Date: 8 O 1/ 14/20 1 9 Drawn ,By: . EM,IL „ \ \ Checked By:, NRf' / Revisions: l \ 07-2G-18 ORIGINAL SUBMITTAL \ \ 0 10-23-18 PER DEVELOPER 12-1 G-1 8 PfR TOWN of CRANiTf QUARRY \ \ O 1 -1 4-1 9 PfR TOWN of CRANiTf QUARRY \ Sheet Title: C y LANDSCAPING \ PLAN \ \ \ Sheet No: i C�300 NPDES Stormwater Discharge Permit for Constnrdien Adivities (NCG01) STABILIZATION TIMEFRAMES (Effective Aug. 3. 2011) SITE AREA DESCRIPTION STA13IL12ATION Tm EFRAME EXCEPTIONS Perimeter dikes, swales, ditches, slopes 7 days None High Quality Water (HQW) Zones 7 days None Slopes steeper than 3:1 emu\ 7 days If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed. QSlopes 3:1 flatter 14 days 7 days for than 50' in length. or slopes greater All other areas with slopes flatter than 41 14 days None, except for perimeters and HOW Zones. NCDENRIDivision of Energy, Mineral and Land Resources I I \ \ \ / � 7 NOTE: ANY CONCRETE WASHOUT STATION AND STOCKPILES SHOULD NOT BE LOCATED WITHIN 50 FEET OF ANY STORM DRAIN, BASIN, OR STREAM UNLESS NO ALTERNATIVE IS FEASIBLE. [G.S. 143-215.1] / NOTE:_ ANY OFF -SITE BORROW AND WASTE REQUIRED FOR THIS PROJECT MUST COME FROM A SITE WITH AN APPROVED EROSION CONTROL PLAN, A SITE REGULATED UNDER THE MINING ACT OF 1971, OR A LANDFILL REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT. TRASH/DEBRIS FROM DEMOLITION ACTIVITIES OR GENERATED BY ANY ACTIVITIES ON SITE MUST BE DISPOSED OF AT A FACILITY REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT OR PER DIVISION OF SOLID WASTE MANAGEMENT OR DIVISION OF WATER RESOURCES RULES AND REGULATIONS. [15A NCAC 46 .01101 / / \ � � � ? � l \ \ I TI NOTE: ALL INLETS ARE TO BE EMBOSSED WITH FISH LOGO AND "DUMP NO WASTE, DRAINS TO STREAM?' OR / / ! C - e� EQUIVALENT APPROVED LANGUAGE. � /�C. � / .54 ME TER- LA IC UTILI BOXES _'PVMT � OVERALL CONSTRUCTION SEQUENCE: / / I 1. SETUP AN ON -SITE PRE -CONSTRUCTION CONFERENCE WITH NCDEQ EROSION CONTROL INSPECTOR AND/OR LOCAL MUNICIPAL REPRESENTATIVE TO DISCUSS CONSTRUCTION.\\\ FAILURE TO SCHEDULE SUCH CONFERENCE 48-HOURS PRIOR TO ANY LAND DISTURBING ACTIVITIES IS A VIOLATION OF H � / / \ / I \ / �/ LOCAL CODE AND MAY BE SUBJECT TO FINES OR OTHER PENALTIES. 2. SURVEY AND FLAG THE DENUDED LIMITS. 3. INSTALL CONSTRUCTION ENTRANCE. / I T 4. INSTALL SILT FENCE, STONE OUTLETS, SKIMMER SEDIMENT BASIN (ST 1), AND OTHER MEASURES (AS SHOWN ON THIS SHEET); CLEARING ONLY AS NECESSARY TO INSTALL THESE DEVICES. 5. SEDIMENT BASIN NEEDS TO BE STABILIZED IMMEDIATELY AFTER INSTALLATION. / ` 6. CALL FOR ON -SITE INSPECTION BY NCDEQ INSPECTOR. WHEN APPROVED, CONTRACTOR MAY THEN BEGIN CLEARING \ / / % AND GRUBBING THE REMAINING PORTIONS OF AREA. 7. MAINTAIN EROSION CONTROL DEVICES AS NECESSARY. 8. STABILIZE SITE AS AREAS ARE BROUGHT TO FINISH GRADE. REFER TO DETAIL SHEET C-5.1 FOR SEEDING. 10. CONTRACTOR TO COORDINATE WITH EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF ANY EROSION CONTROL// MEASURES. \ // /// / 11. ONCE SITE IS STABILIZED, SEDIMENT BASIN ST-1 MAY BE REMOVED. / //O0�/ / / FLOOR EROSION CONTROL NOTES: \ / ��. / / =819.76' 1. ALL "REFERENCE" NUMBERS REFER TO NCDEQ MANUAL UNLESS OTHERWISE NOTED. 5 O DUKE POWER E S � N T ° / �// A�' / / 2. ON -SITE BURIAL PITS MAY REQUIRE AN ON -SITE DEMOLITION LANDFILL PERMIT FROM THE LOCAL ZONING�// /�/ cb"�/// / \ \ \ \ \ \\ \^ \ ADMINISTRATOR. // /�� I I 1 I \ STING 782 PG° 904 // HYDRANT 3. ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION OF THE STATE EROSION CONTROL (D.B. ) \ / / / / Q I \ \ 810.00_ \ ORDINANCE AND IS SUBJECT TO A FINE. 4. GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION OF THE COUNTY EROSION CONTROL ORDINANCE AND IS SUBJECT TO A FINE.1/4 STABILIZATION:5. GROUND 6. ADD T ONALMEASURSADJACENT STABILIZATION M ES TOCONTROLEROSION ANDSED MENT MAY REQUIRED BY A REPRESENTATIVE OF THE TOWN, / q / 1 TI / � / / � TBM /COUNTY OR NCDEQ. l I YDR�AN �� \ F TER / s / 7. SLOPES SHALL BE GRADED NO STEEPER THAN 2:1. FILL SLOPES GREATER THAN 10' REQUIRE ADEQUATE TERRACING. EMBANKMENT MATTING MAY BE REQUIRED FOR SLOPES STEEPER THAN 3:1 BASED ON MATERIAL. APPROVED. �' DING PLAN MUST BE SUBMITTED FOR ANY GRADING EXCEEDING ONE ACRE THAT WAS NOT PREVIOUSLY s EX. DRAIN 9. TEMPORARY DRIVEWAY PERMIT FOR CONSTRUCTION ENTRANCES IN NCDOT RIGHT OF WAY MUST BE PRESENTED AT I / ' /// / / /✓ / DO / \ 9s. \\\\ $� __ / PRE-COSNTRUCTION MEETING. (IF APPLICABLE) I Y l 11 �� s9\ c� N - �- // \ EXISTING HYDRANT MAINTENANCE PLAN: THE FOLLOWING MAINTENANCE PLAN SHALL BE FOLLOWED FOR EROSION AND SEDIMENT CONTROL DEVICES UNTIL THE SITE IS I I l� COMPLETELY STABILIZED AND AFTER CONSTRUCTION FOR STORM WATER MANAGEMENT DEVICES THROUGHOUT THE LIFECYCLE !S F.FL OR OF THE DEVELOPMENT. DURING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTION AND / F+=819.66' MAINTENANCE OF ALL EROSION CONTROL FEATURES. FOLLOWING CONSTRUCTION, THE OWNER/RESPONSIBLE PARTY IS RESPONSIBLE FOR INSPECTION AND MAINTENANCE OF ALL STORM WATER MANAGEMENT FEATURES. I / / 1 �� 'v s�8� ' '6 I// 1. ALL EROSION CONTROL MEASURES WILL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING ANY RAINFALL lN✓/It PCONTROL RODUCING MEASURES ARE MAINTAINED ADESIGNED. WEEK. Y NEEDED REPAIRS WILL BE MADE IMMEDIATELY SO THAT ALL EROSION 2. THE SEDIMENT TRAPS WILL BE CLEANED OUT WHEN THE LEVEL OF SEDIMENT REACHES APPROXIMATELY ONE HALF OF THE TRAP OR BASIN VOLUME. 3. ALL SEEDED AREAS WILL BE FERTILIZED, RE -SEEDED AS NECESSARY, AND MULCHED ACCORDING TO THE SEEDING EXIST r \�\ 1 � 1 J�j � -y� \ SPECIFICATIONS AND THE REMEDIATION PLAN IN ORDER TO MAINTAIN A DENSE VEGETATIVE COVER. f CONSTRUCTION ENTRANCE )1 CONSTRUC ON ENTRANCE 4. ALL SEEDED AREAS WILL BE RE -FERTILIZED IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. GRASSED HYDRANT (SEE DETAIL I I I 1 / \ I I L, (SEE D AREAS WILL BE MOWED AT LEAST ONCE A YEAR. X \ F WOOR=819.3 ET IL 3/5.0) \\ ) DIR� ION `�\ UNKNOWN % SELF INSPECTIONS / �( / �I 1 / INV =8 7.18 80500 L / EFFECTIVE OCTOBER 1, 2010, PERSONS RESPONSIBLE FOR LAND DISTURBING ACTIVITIES MUST INSPECT THE SEDIMENT AND sO EROSION CONTROL MEASURES ON A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED ' I/ I 0�, EROSION AND SEDIMENTATION PLAN IS BEING FOLLOWED. SELF -INSPECTION REPORTS ARE REQUIRED. A SAMPLE SELF -INSPECTION REPORT, AS WELL AS DETAILS OF THE SELF -INSPECTION PROGRAM, CAN BE FOUND ON THE LAND QUALITY WEB SITE: httt : //dea.nc.gov/about divisions energy-mineral-land-resources/erosion-sediment-control / \ TBM TOP FH � AS A MINIMUM, THE INSPECTIONS SHALL BE PERFORMED AFTER EACH OF THE FOLLOWING PHASES OF A PLAN: ) \ \ \ \ \ \ \ �� O/ / tit � 1"5. /3'� O 'I 1. INSTALLATION OF PERIMETER EROSION AND SEDIMENT CONTROL MEASURES. / / / / l J 1 \ \ \ y� 2. INSTALLATION OF SEDIMENT TRAPS/BASINS. I \ I iY/ 3. CLEARING AND GRUBBING OF EXISTING GROUND COVER. INLET ZONE \ / 4. COMPLETION OF ANY PHASE OF GRADING THAT REQUIRES PROVISION OF STABILIZATION. / / \ / \ / / / / (SEE DETAIL 6/5.0) 5. INSTALLATION OF MEASURES DURING ANY PHASE OF THE PROJECT. 6. COMPLETION OF CONSTRUCTION OR DEVELOPMENT. l l l l l l l / \ \ \ \� \ Ff / / / / /�� / \\ \ OUTLET ZONE �iSj� /// (SEE DETAIL 6/5.0) / 7. INSTALLATION OF STORMWATER RETENTION MEASURES. O / / / / ✓ 8. QUARTERLY UNTIL THE ESTABLISHMENT OF PERMANENT GROUND COVER IS FULLY ESTABLISHED. / / co, / / / / I \ /00 / / / / 0���2 / S IMENT^WN PLEASE NOTE THESE INSPECTION REQUIREMENTS ARE IN ADDITION TO NPDES INSPECTION REQUIREMENTS. IF YOU HAVE / I I � r \ \ ♦�OCK C1K DAM G� / � / / QUESTIONS ABOUT THE SELF -INSPECTION PROGRAM, PLEASE CONTACT US AT (704) 663-1699. l l l I O I �- �-- I (SEE DETAIL 2/5.1) `�� / / �ASI ` PHASE I SKIMMER SEDIpO(ENT TRAP 00 I � I (SE ET � � \ S I SEE DETAIL (1/5.0) / J I I J / / /� - 0 8SORIF^ICEIU1S/ / l j / 00 _\ I ST-1 DRAINAGE AREA (PHASE 1 C 2) \ / // \ EMERGENCY SPILLWAY 1.6" ORIFICEZIAMETER / LEGEND / / I / ' I O \ 2.46 ACRES \ /� /F L00RA19.3/ /EX�I \\\\ \\ / STONE OUTLET / I/ /� ( O 1 / / �j�o / ' ' ' D ' SEDIM NT ( SEE DETAIL 6/5.1) (SEE DET�(IL 7/5.0) SUBJECT PROPERTY BOUNDARY / % I J J / PR OSED NCRETE WASHOUT \ /$� / �- \ \ % 1 ( E DETAIL 9/5.1) \ BASIN AFFLE EXISTING SANITARY SEWER EASMENT / / / )� 1 \ / \ >(SEE DETAIL 6/5.0) EXISTING 68' DUKE POWER R/W / / �^ \/ EXISTING / �> �b� EXISTING 50' DUKE POWER EASMENT/ / ADJACENT PROPERTY I I�YDRANT �' / 7+ /`b / / PROP. SILT FENCE \ / X X EXISTING FENCE / / f 1 J \ ��,� j 10��j // (SEE DETAIL 1/5.1) PROPOSED BUILDING EXPANSIONTEMPORARY / TOPOGRAPHY DIVERSION DITCH PROPOSED FENCE I / / I �- -� \ +� / / // \ (SEE DETAIL 3/5.1) / SILT FENCE (DETAIL 1 /5.1) ! / / l PHASE � / / ROCK CHECK DAM (DETAIL 2/5.1) I / , sTU?R6 ARF1\ -810.00- / C / SILT FENCE OUTLET (DETAIL 6/5.1) I ' �(2.24A S) f �/ 100, INLET PROTECTION (DETAIL 2/5.0) +� / % / / \ TEMP. DIVERSION DITCH (DETAIL 3/5.1) DRAINAGE AREA DISTURBED AREA / / / \ \ ♦ / TOP OF POND ROUGHED IN GRAPHIC SCALE I I I V j B 0p.00- 60 0 30 60 120 COPYRIGHT ©2019 AMICUS PARTNERS PLLC. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS ADJACENT PROPERTIES REFERENCED FROM A SURVEY CONDUCTED BY CABARRUS COUNTY DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT GIs. PROPERTY DIMENSIONS AND COORIDINATES FOR PROPERTY REFERENCED FROM OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY CABARRUs COUNTY GIS. COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VALID, TRUE COPIES. Firm License # P-1191 7140 Weddinton Road Suite 140 Concord, NC 28027 Civil Site Design Low Impact Development Small -Scale Building Design Telephone: 704.573.1621 Facsimile: 704.248.7951 MEN- M Seals: \\,,,11111111,,,, N CAR Q SEAL =z g 032006 0 �` i > ° I` %Q,S ��111111111\\\ 12-16-2018 � r• 0 z � o -1 z �Z Project Number: 17-18-092 Date: 1 2/ I G/20 18 Drawn ,By: , EML, Checked By:, NRP, Revisions: 07-2G-18 ORIGINALSUBMITTAL 10-23-18 PER DEVELOPER 1 2-1 G-1 8 FEK Towle Off GRANITE QUARRY Sheet Title: PHASE 1 EROSION CONTROL Sheet C-4.0 ANY OFF -SITE BORROW AND WASTE REQUIRED FOR THIS PROJECT MUST COME FROM A SITE WITH AN APPROVED EROSION CONTROL PLAN, A SITE REGULATED UNDER THE MINING ACT OF 1971, OR A LANDFIL REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT. TRASH/DEBRIS FROM DEMOLITION ACTIVITIES OR GENERATED BY ANY ACTIVITIES ON SITE MUST BE DISPOSED OF AT A FACILITY REGULATED BY THE DIVISION OF SOLID WASTE MANAGEMENT OR PER DIVISION OF SOLID WASTE MANAGEMENT OR DIVISION OF WATER RESOURCES RULES AND REGULATIONS. [15A NCAC 4B .01101 / I TW NOTE: / _ \ �- Il '(_. ALL INLETS ARE TO BE EMBOSSED WITH FISH LOGO AND "DUMP NO WASTE, DRAINS TO STREAM." OR _ F y PROP. SILT FENCE _ , e� EQUIVALENT APPROVED LANGUAGE. /C• / 54 / \ ME TER - (SEE DETAIL 1/5.1) / /� LA� IC UNIT �^ w Bow / BOXES / /V NOTE: PHASE II OF THIS PLAN SHAL NOT COMMENCE UNTIL PHASE I IS COMPLETELY/ STABELIZED. Jrf I MTQ011, PROPOSED RETAINING m( \ \ \ \ \ / / ///� • / / .O \ \ \ �� �� WALL BY OTHER. PLANS HAVE BEEN SUBMITTED SEPARATELY. OVERALL CONSTRUCTION SEQUENCE: I /Y /1. SETUP AN ON -SITE PRE -CONSTRUCTION CONFERENCE WITH NCDEQ EROSION CONTROL INSPECTOR AND/OR LOCAL / \ / 7 / \JB3A MUNICIPAL REPRESENTATIVE TO DISCUSS CONSTRUCTION. CONSTRUCTION ENTRANCE / / FAILURE TO SCHEDULE SUCH CONFERENCE 48-HOURS PRIOR TO ANY LAND DISTURBING ACTIVITIES IS A VIOLATION OF (SEE DETAIL 3/5.0) / / LOCAL CODE AND MAY BE SUBJECT TO FINES OR OTHER PENALTIES. 2. SURVEY AND FLAG THE DENUDED LIMITS. 3. INSTALL CONSTRUCTION ENTRANCE. / ti \ p \ ��� /\ \� \� le J 4. INSTALL SILT FENCE, STONE OUTLETS, SKIMMER SEDIMENT BASIN (ST-2), AND OTHER MEASURES (AS SHOWN ON THIS SHEET); CLEARING ONLY AS NECESSARY TO INSTALL THESE DEVICES. 5. SEDIMENT BASIN NEEDS TO BE STABILIZED IMMEDIATELY AFTER INSTALLATION. 18.58 6. CALL FOR ON -SITE INSPECTION BY NCDEQ INSPECTOR. WHEN APPROVED, CONTRACTOR MAY THEN BEGIN CLEARING ti6 \ / / % AND GRUBBING THE REMAINING PORTIONS OF AREA. 7. MAINTAIN EROSION CONTROL DEVICES AS NECESSARY. 8. STABILIZE SITE AS AREAS ARE BROUGHT TO FINISH GRADE. REFER TO DETAIL SHEET C-5.1 FOR SEEDING. 10. CONTRACTOR TO COORDINATE WITH EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF ANY EROSION CONTROL \ / / / � � / / / / � � � INLET ZONE MEASURES. //(SEE DETAIL 6/5.0) \ \ 11. ONCE SITE IS STABILIZED, SEDIMENT BASIN ST-2 MAY BE CONVERTED TO SAND FLITER SF-1 PER SHEET C-6.0. / � / FLOOR O \ PHA-S€JI SKIMM €R DI EN � EROSION CONTROL NOTES: \ / ��� / / / / /=819.76' F \ g o ` TRAP (SE �b TA 11/5.63, \ \ 1. ALL "REFERENCE" NUMBERS REFER TO NCDEQ MANUAL UNLESS OTHERWISE NOTED. 5 O DUKE POWER E S N T < / / , // / // // / ` OUTLET ZONE 2. ON -SITE BURIAL PITS MAY REQUIRE AN ON -SITE DEMOLITION LANDFILL PERMIT FROM THE LOCAL ZONING /// // //// // / / ( SEE DETAIL 6/\\ \ ADMINISTRATOR. \ / / /- /O� / I 1 I SEDIM NTSKIMMER 3. ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION OF THE STATE EROSION CONTROL (D. B . 782 P G . 9 0 4) \ / // j/� i��i // / / / SEE�BASIN ST- JB3= \ \ 4. GRADING MORE THANNANCE AND IS ONE ACRE CT TO A IWITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION OF THE COUNTY / / 1 ( ) 4B 2.5"SKIM R \ / / \ SEDI T \\ / 1" ORIFICE RADIUS EROSION CONTROL ORDINANCE AND IS SUBJECT TO A FINE. / / / PHASEI\ BASIN FF \ ORIFICE DIAMETE� \ 5. GROUND STABILIZATION: SEE ADJACENT NEW STABILIZATION TIMEFRAME CHART. DISTURBED AREA �° �� / / / OO. (S DE IL 6/5.0 \ / ( EEb TAIL I5.0) 6. ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIRED BY A REPRESENTATIVE OF THE TOWN, 2.14 ACRES m y \ COUNTY OR NCDEQ. 7. SLOPES SHALL BE GRADED NO STEEPER THAN 2:1. FILL SLOPES GREATER THAN 10' REQUIRE ADEQUATE TERRACING. j� / \ \ ES2 EMBANKMENT MATTING MAY BE REQUIRED FOR SLOPES STEEPER THAN 3:1 BASED ON MATERIAL. PROP. SILT FENCE \ 8. A GRADING PLAN MUST BE SUBMITTED FOR ANY GRADING EXCEEDING ONE ACRE THAT WAS NOT PREVIOUSLY (SEE DETAIL 1/5.1) X. / EDRAIN \ / ��' \a VED. 9. TEMPORARY DRIVEWAY PERMIT FOR CONSTRUCTION ENTRANCES IN NCDOT RIGHT OF WAY MUST BE PRESENTED AT SILT FENCE OUTLFjT /✓ / S�� \ 9s,- O' PRE-COSNTRUCTION MEETING. (IF APPLICABLE) (SEE DETAIL 6/5.1): �� `q` \ N 7- MAINTENANCE PLAN: THE FOLLOWING MAINTENANCE PLAN SHALL BE FOLLOWED FOR EROSION AND SEDIMENT CONTROL DEVICES UNTIL THE SITE IS I (% / =81819.OR66' COMPLETELY STABILIZED AND AFTER CONSTRUCTION FOR STORM WATER MANAGEMENT DEVICES THROUGHOUT THE LIFECYCLE / / I OF THE DEVELOPMENT. DURING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTION AND�F+/S MAINTENANCE OF ALL EROSION CONTROL FEATURES. FOLLOWING CONSTRUCTION, THE OWNER/RESPONSIBLE PARTY IS RESPONSIBLE FOR INSPECTION AND MAINTENANCE OF ALL STORM WATER MANAGEMENT FEATURES. P �/ / I /I �` 1 I 1. ALL EROSION CONTROL MEASURES WILL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING ANY RAINFALL INV.= 6. ( . \ J PRODUCING RUNOFF AT LEAST ONCE A WEEK. ANY NEEDED REPAIRS WILL BE MADE IMMEDIATELY SO THAT ALL EROSION I I ✓I I S� CMP CONTROL MEASURES ARE MAINTAINED AS DESIGNED. / 2. THE SEDIMENT TRAPS WILL BE CLEANED OUT WHEN THE LEVEL OF SEDIMENT REACHES APPROXIMATELY ONE HALF OF / \ \ THE TRAP OR BASIN VOLUME. �V / / \ \\ J� »> J)>l / j \ I / \ 3. ALL SEEDED AREAS WILL BE FERTILIZED, RE -SEEDED AS NECESSARY, AND MULCHED ACCORDING TO THE SEEDING /J SPECIFICATIONS AND THE REMEDIATION PLAN IN ORDER TO MAINTAIN A DENSE VEGETATIVE COVER. II 4. ALL SEEDED AREAS WILL BE RE -FERTILIZED IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. GRASSED I / I I I I 1 \ F.FLOOR=819.35' AREAS WILL BE MOWED AT LEAST ONCE A YEAR. R8CTI0 /NKNOW SELF INSPECTIONS / 1 / I =8 7.4 8p50/ EFFECTIVE OCTOBER 1, 2010, PERSONS RESPONSIBLE FOR LAND DISTURBING ACTIVITIES MUST INSPECT THE SEDIMENT AND EROSION CONTROL MEASURES ON A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION PLAN IS BEING FOLLOWED. SELF -INSPECTION REPORTS ARE REQUIRED. A SAMPLE SELF -INSPECTION REPORT, AS WELL AS DETAILS OF THE SELF -INSPECTION PROGRAM, CAN BE FOUND ON THE LAND QUALITY WEB SITE: httt : //dea.nc.gov/about divisions energy-mineral-land-resources/erosion-sediment-control AS A MINIMUM, THE INSPECTIONS SHALL BE PERFORMED AFTER EACH OF THE FOLLOWING PHASES OF A PLAN: J \ \ \ \ \ \ \ OO 1. INSTALLATION OF PERIMETER EROSION AND SEDIMENT CONTROL MEASURES. 2. INSTALLATION OF SEDIMENT TRAPS/BASINS. 3. CLEARING AND GRUBBING OF EXISTING GROUND COVER. 4. COMPLETION OF ANY PHASE OF GRADING THAT REQUIRES PROVISION OF STABILIZATION. 5. INSTALLATION OF MEASURES DURING ANY PHASE OF THE PROJECT. 6. COMPLETION OF CONSTRUCTION OR DEVELOPMENT. 7. INSTALLATION OF STORMWATER RETENTION MEASURES. / /:/� / / / / \ \ s�7.� o o // \\\�� /// ✓ / 8. QUARTERLY UNTIL THE ESTABLISHMENT OF PERMANENT GROUND COVER IS FULLY ESTABLISHED. / / / /� �� PLEASE NOTE THESE INSPECTION REQUIREMENTS ARE IN ADDITION TO NPDES INSPECTION REQUIREMENTS. IF YOU HAVE QUESTIONS ABOUT THE SELF -INSPECTION PROGRAM, PLEASE CONTACT US AT (704) 663-1699. LEGEND NPDES Stormwater Discharge Permit for Constn¢ticn Adivities (NCGO1) ANY CONCRETE WASHOUT STATION AND STOCKPILES SHOULD NOT BE LOCATED WITHIN 50 FEET OF ANY / NCDENPJDivision of Energy, Mineral and Land Resources STORM DRAIN, BASIN, OR STREAM UNLESS NO ALTERNATIVE IS FEASIBLE. [G.S. 143-215.1 ] \ \ STABILIZATION TIMEFRAMES (Effective Aug. 3. 2011) SITE AREA DESCRIPTION STA13IL12ATION TIMEFRAME EXCEPTIONS Perimeter dikes, swales, ditches, slopes 7 days None High Quality Water (HQW) Zones 7 days None Slopes steeper than 3:1 Lug 7 days If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed. �! Slopes 3:1 flatter 14 days 7 days for than 50' in length. or slopes greater All other areas with slopes flatter than 41 14 days None, except for perimeters and HOW Zones. cs 00 /F.FLOOR,-61 SUBJECT PROPERTY BOUNDARY / J I J J / PR OSED NCRETE WASHOUT \ 15' / / \ \\\ EXISTING SANITARY SEWER EASMENT E DETAIL 9/5.1) EXISTING 68' DUKE POWER R/W EXISTING 50' DUKE POWER EASMENT X X EADJACENT XISTING FEN OE ERTY PROPOSED BUILDING EXPANSION TOPOGRAPHY PROPOSED FENCE SILT FENCE (DETAIL 1/5.1) I / J ROCK CHECK DAM (DETAIL 2/5.1) SILT FENCE OUTLET (DETAIL 6/5.1) ! ' ' �810.00-/�/�/� INLET PROTECTION (DETAIL 2/5.0) - TEMP. DIVERSION DITCH (DETAIL 3/5.1) I � 1 -• � � � \� � � � / / � / / //� �� ��/��// / � \ DRAINAGE AREA GRAPHIC SCALE TOP OF POND I / ROUGHED IN 60 0 30 60 120 COPYRIGHT © 2019, AMICUS PARTNERS, PLLC. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS ADJACENT PROPERTIES REFERENCED FROM A SURVEY CONDUCTED BY CABARRUS COUNTY DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT GIS. PROPERTY DIMENSIONS AND COORIDINATES FOR PROPERTY REFERENCED FROM OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY CABARRUS COUNTY GIS. COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VALID, TRUE COPIES. PLAN VIEW 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPRQACHING THE INLET. 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING SKIMMER SEDIMENT BASIN THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE DESIGN CRITERIA INLET, A MAXIMUM OF 4 FEET APART. NPDES Sb-W Duchargo PB0n1rarConsaurfiGt AI x .D NCGO1) NCDENWDivNion or Energy, Mineral and Land R-m 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE AND BOTTOM. DRAINAGE PLACING A 2-FOOT FLAP OF THE WIRE MESH UNDER THE GRAVEL GENERAL NOTES: STABILIZATION TIMEFRAMES AREA < 10 AC. MBANKMENT FOR ANCHORING IS RECOMMENDED. (ElNcexe Au5.3,18111 (ACRES) LENGTH 4. PLACE CLEAN GRAVEL (NC DOT #5 OR #57 STONE) ON A 2:1 SLOPE 1. A STABILIZED ENTRANCE PAD OF #5 WASHED STONE OR RAIL ROAD BALLAST SHALL BE LOCATED WHERE TRAFFIC WITH A HEIGHT OF 16 INCHES AROUND THE WIRE AND SMOOTH TO AN WILL ENTER OR LEAVE THE CONSTRUCTION SITE ONTO A PUBLIC STREET. EVEN GRADE. SITE AREA DESCRIPTION STABILI2 TIDN TIMEFRAME EXCEPTIONS MIN. INFLOW 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE 2. FILTER FABRIC OR COMPACTED CRUSHER RUN STONE SHALL BE USED AS A BASE FOR THE CONSTRUCTION LENGTH TO 2:1 STRUCTURE ACCUMULATED SEDIMENT AND ESTABLISH FINAL GRADING ELEVATIONS. ENTRANCE. Perimeter dikes, swales. ditches, slopes 7days None WIDTH RATIO 10' MIN. 6. COMPACT THE AREA PROPERLY AND STABILIZE IT WITH GROUNDCOVER. 3. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT NOTES: ONTO PUBLIC STREETS OR EXISTING PAVEMENT. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL High Quality Water lHQWf)Zones Tdays None Amieus Partners, PLLC MAX. STONE AS CONDITIONS WARRANT AND REPAIR OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. LENGTH TO 6:1 1. REFER TO WIDTH RATIO NCESCPDM 4. ANY SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO PUBLIC STREETS MUST BE REMOVED IMMEDIATELY. SKIMMER Slopes steeper than 3:1 7 days Ir Slopes are W Dr lessIn length and are DEWATERING SECTION #6.64 INC DOT 15 OR #57 not sleeper then 2.1, 14dLys ere Ml Mxed. MIN. 1800 _ AREA* { DEVICE FOR ADDITIONAL WASHED STONE 5. WHEN APPROPRIATE, WHEELS MUST BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTERING A PUBLIC STREET. WHEN VOLUME (CU. FT. AWIDTHE LENGTH DESIGN WASHING IAPPROVEDSSEDMEINT BASINHSEE STD. NO. RED, IT SALL BE DONE 1515.N AREA STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN Firm License # P-1191 REQUIRED PER AC. MERGENCY SPECIFICATIONS Slopes 3:1 Or HOMES 14 days 7Cays for WOMB grealer than 50• in length. DISTURBED) * AREA OF BASIN WATER SPILLWAY REGARDING 6. TOWN MAY REQUIRE A STANDARD COMMERCIAL DRIVEWAY TO ACCESS THE CONSTRUCTION SITE IF THE DRIVEWAY IS 7140 Weddinton Road SURFACE AT TOP OF SKIMMER SEDIMENT ON A THOROUGHFARE. Suite 140 325 PRIMARY SPILLWAY BASINS. All other areas with slopes hatter than 4:1 4days None, except for perimeters and HOW Zones. SURFACE (SQ. �, -� Concord, NC 28027 AREA PER CFS 2. REFER TO STD. (1/4 INCH HARDWARE CLOTH a' MAX. REQUIRED Q10) BAFFLES #524.1 FOR (1/4 INCH MESH OPENINGS) 100 FT (MIN) PUBLIC STREET CIVII Site Design CROSS-SECTION VIEW BAFFLE SPACING - --------------------------- - 1' FREEBOARD W=5' MIN. AND INSTALLATION. - _ -III-II = _ _ _ - -'7 6" MAX. DEPTH OF FLOW OVER MBANKMENT EXISTING GROUND -I I= _ I -I II -I I -I I -I I -I I-� LowImpact INFLOW EMERGENCY SPILLWAY I I III -I I -I I -III -III -III -III -III -III -I STRUCTURE BAFFLES MIN. 1' T=1.5' MIN. 3' I z' EQUIVALENT OVENMICEO XTILE -III-II1=1II-III-IiI-- #5 WASHED STONE Q Small -Scale Building Design Z=5' MAX. -TEMPORARY SILT DITCH 1 OR FLATTER Telephone: 704.573.1621 NC DOT #5 OR #57 100 FT (MIN) SEE DETAIL STD. 30.05 2 o Facsimile: 704.248.7951 DEWATERING - - WASHED STONE SEE NOTE ZON H=2 MIN. MERGENCY Seals: SPILLWAY °D FILTER FABRIC c DO 10' CONSTRUCTION \ \177771I1(11y77 / SEDIMENT ANTI - SEEP �``\ \ N CA/? STORAGE ZONE NOT TO SCALE COLLAR EEP z 1 OR FLATTER '77., TEMPORARYlTm1 SILT FENCE 2 _ °°�' �-y , SEE DETAIL - ° Q SEAL r SKIMMER SEDIMENT TRAP DATA BLOCK b STD. 5os.1 03200E ' SK;M(A INAGE DENUDED BASIN VOLUME BASIN SURFACE AREA CLEANOUT H Z L T W SKIMMER SKBMW= IMMER SKIMMER =z TEA AREA QIO REQUIRED PROVIDED REQUIRED PROVIDED DEPTH (FT.) (FEET) (FEET) (FEET) (FEET) (FEET) PIPE ORIFICE ORIFICE 2-3 INCH COARSE AGGREGA WIRE MESH ES) (ACRES) (CUBIC FT.) (CUBIC FT.) (SQ FT.) (SQ FT.) H/2 DIAMETER DIAMETER RADIUS S46 2.46 10.72 4,428 13,125 3,484 4,613 1.25 2.5 4.0 16.0 1.5 5.0 2.0" 1.6" 0.8" „ %0 °°°°°S33 2.25 20.75 7,794 17,297 6,744 7,142 1.25 2.5 4.0 16.0 1.5 5.0 2.5" 2.0" 1.0" Hardware Cloth & Gravel Inlet Protection Detail ///", 4 A S R • 1````\ M_2 yf111Iu11`1 _ _ 2 FT (MIN) Ref: NCDENR Construction Entrance Detail 01-14-2019 1 Skimmer Sediment Trap Detail 50 Ref: NCDENR #6.06.1 o Slope Stability 5.0 Ref: MOLDS Standard #30.16 Ref: NCDENR #6.64.7 NOTES: - OF SURFACE AREA 1. A MINIMUM OF 24" FROM OUTSIDE DIAMETER OF PIPE TO SIDE INLET ZONE 25% OF SURFACE AREA WATER ENTRY UNIT OF TRENCH MUST BE ALLOWED FOR COMPACTION OF FILL INLET ZONE 25% GENERAL NOTES: WITH TRASH SCREEN GENERAL NOTES: OF SURFACE AREA PROPER DESIGN MUST BE COMPLETED TO MINIMIZE PIPING AROUND DISCHARGE PIPE. MATERIAL. BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED c 1. DRIVE 5' STEEL POST AT LEAST 2. PROP ER ORIFICE OPENING MUST BE SELECTED TO ENSURE POND DRAINS IN CORRECT AMOUNT OF TIME. MODIFICATIONS MAYBE REQUIRED IF FIELD CONDITIONS WARRANT A p z IMMEDIATELY AFTER THE PIPE IS LAID. THE FILL AROUND THE ��i OUTLET ZONE 15% 24" INTO SOLID GROUND. CHANGE. 3. EMBANKMENT MUST BE COMPACTED TO DESIGN SPECIFICATIONS. ~ 2" WEEP HOLES GENERAL NOTES:. H T PIPE SHALL BE PLACED IN LAYERS NOT TO EXCEED 6". OF SURFACE AREA 4. EMERGENCY SPILLWAY MUST BE CORRECTLY SIZED AND EROSION PROTECTION INSTALLED. �,• 2 Y usE cuss"e" CONCRETE THRO NMNouT. <a 2. USE STAPLES 1' APART 5. EROSION PROTECTION MUST BE INSTALLED ALONG THE EMBANKMENT AND AT THE 2 Tn O ^� UNDER NO CIRCUMSTANCES SHALL WATER BE PERMITTED HORIZONTALLY AND VERTICALLY DISCHARGE END OF THE PIPE. D �Oa PRDVIDIS ALL CODE INLETS OVER 3'-8" IN DEPTH WITH STEPS 12" Hy�C7L ORIFICE OPENING INSIDE THE 6. INSPECT SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING IN A CORRECT MANNER. r- z T =� I I ON CENTER, USE STEPS WHICH COMPLY WITH STD. DRAWING "0.88. TO RISE IN UNBACKFILLED TRENCHES AFTER THE PIPE HAS BEEN TO ATTACH THE POROUS ORIZONTALTUBE WITH N 1 -4D OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR W4 MAR DOWELS AT 7. EIGHT SIZES OF SKIMMERS ARE AVAILABLE, REFER TO THE FLOW SHEET, CUT SHEET, AND F BAFFLES TO THE WIRE FENCE. coNSTANrHYDRAuucHEAD G:-n>> i 12"USE CENTERS AS HE CON O BY THE ENGINEER, LLJ cc _ PLACED. COMPACTION REQUIREMENTS SHALL BE ATTAINED BY tOk INSTRUCTIONS ON WEB SITE FOR EACH SIZE. =�ZDRI X I X USE FORMS FOR THE CONSTRUC ION OF THE BOTTOM SLAB. I-UOCO� IF REINFORCED CONCRETE PIPE I$ SET IN BOTTOM SLAB OF BOX, ADD TO SLAB < f- z THE USE OF MECHANICAL TAMPS ONLY. EACH AND EVERY LAYER / X 3. MINIMUM BAFFLE SPACING IS 10'. z,2,-a�� -� -- --, AS SHOWN ON BID, NO. a40,OO. E-� 0o OF BACKFILL SHALL BE PLACED LOOSE AND THOROUGHLY COMPACTED t7=IOz - - - I CONSTaucr WITH PIPE CROWNS MATCHING. d0 < SCHEDULE 40 PVC PIPE '�. D - - , GEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES NOT SHOWN. z OT INTO PLACE. \ 4. THE FLOOR OF THE BASIN IN (BARRELORARM) D� INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. E- THE OUTLET ZONE AND BERMS FLOW XC" M INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF No. TOM STONE IN A d O 2. ALL BACKFILL MATERIAL SHALL HAVE AN IN PLACE COMPACTED DENSITY OF 95%. SHOULD BE SEEDED IMMEDIATELY Z i POROUS FABRIC SAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER. 7 o AFTER THE BASIN IS CRANNIES ALL EXPOSED CORNERS 1". 3. STANDARD PROCTOR. THE FINAL 2' BELOW FINISHED GRADE SHALL BE 100%. a CONSTRUCTED. LEXIBLE HOSE ARTHEN EMBANKMENT Y DRAWING NOT TO SCALE. FLOAT MERGENCY SPILLWAY PLAN 4. ALL TRENCHING OPERATIONS SHALL MEET OSHA STANDARDS. / i 5. REFER TO NCESCPDM SE TION PVC VENT WITH GRATE & FRAME REMOVED 5. BACKFILL MATERIAL BENEATH ROADWAY SHALL BE SELECT BACKFILL MATERIAL. / fgRTN S6.65 FOR ADDITIONAL PIPE X PECIFIATIONS. O l / fRM TOP VIEW SCHEDULE 40 PVC PIPE LOAT znot.. TOP ELEVATION C5 e BRICK COPING(INCIDENTAL) EL (BARRELORARM) O LL O Fr -I aBID. 440.1 6FRAMt ui / 1 VC VENT PIPE ZG GRlfTE 2- FLEXIBLE HOSE n = 124 BAR ►z"I 7- W v J otJT� N m 1 g H O 0 u l a POTENTIAL FOR PIPING CAN - jib z = Q q x OCCUR. PROPER DESIGN TO C D ca Q 1+A MINIMIZE DISCHARGE AROUNDPIPE MUST OCCUR. O d W 2 �--��� O O III -I III-1 /x _ 1II-I OUTSIDE DIAMETER III_ X X/ a DOWEL WI- H 1 I -I III-Ii WATERENTRYUNIT m Z SEE NOTE DOWEL(SEE NOTE) MAX. PIPE THIS SIDE1 N Fjly III Z II -I III-' m CO SECTION x-K SECTION Y-Y � O �JI 4'-0" MAX. SPACING 5' STEEL POST W O I -I III_ MAINTAIN DEPRESSION TO DIMENSIONS AND QUANTITIES FOR DROP INLET (EASED ON MIN. HEIGHT, H = - END VIEW SIDE VIEW DIMENSIONS OF BOX 8 PIPE CUBIC YARDS DEDUCTIONS FOR DISCHARGE PIPE MINIMIZE CHANCE OF SKIMMER PIPE SPAN WIDTH MIN. NEIGH CONC. IN BOX ONE PIPE TYPICAL BOTTOM WALL PER w.e(e VARIES III POROUS MATERIAL scHEDULE 40 (NO SCALE) BECOMING STUCK I\ (15" MIN) (COMBINED JUTE MESH FLOW ,� o D A e x SLAB FT. HT. O.M. R.C. r AND NAG C125 DRAWN BY R EVAN310110 24^ 24" J. W. FAIRCLOTH & SON INC. COCONUT LINER OR I lz^ 3-a �O2o.z2z o.zzz a-6Ga D.o1s o.GWWW.FNRCLOTHSIOMMER. COM 15" 0.646 0. 023 0.036 EQUIVALENT). 8" X 6" TRENCH FAIRCLOTH SKIMMER' DISCHARGE SYSTEM WITH EMBANKMENT ELEPHONE(9,9)T32_,244 IB" D.7D3 a.D33 0.048 BACKFILL AND FAX:(919)732-12ssPIPE SHALL BE PLACED COMPACT FENCE AND EMAIL WARREN@FNRCLOTHSMMMERCOM 24" 0.814 0.059 O.0W ON SUITABLE MATERIAL FABRIC BURIED IN 58401°°i 30" a'^ 6.222 0-222 0.925 0.092 0.12r TRENCH IIII�II IIIIII- 7 Faircloth Skimmer Detail CONCRETE DROP INLET 8 5 Trench Detail for Storm Drain III-- N 5.o Ref: Fairclothskim mer.com 5-o Ref: MCLDS Standard #20.25 6 Baffle Installation Detail 5"0 SCALE: N.T.S. [REF: NCDOT #840.14] 5.0 Ref: MCLDS Standard #30.19 o z L�� E C)CO o SOLID COVER SHOWN PERFORATED. PERFORATED AVAILABLE z IF SPECIFIED, r+� MITI rr N A OPTIONAL MANHOLE I--h} O W fit. 3 -B" I- ¢ MIDI, r� Z E sI ¢ 3 C . STATE USE OF SYSTEM ON COVER 6 Q a ti, a GENERAL NOTES: Z ~ 2 31 ~' Q '�- aCo O 1'r DEPRESSION S,�u r. g�x at.r0ay Y FH�C7v yHpO �_ (I.E.: SEWER, STORM GRAIN, ELECTRICAL) z00� D O 1 j F,Lu H 2 �, U m p 6" MMFER ALL EXPOSED CORNERS 1". LL J K. Z r O T D 2" +--h CR Hz1x7+ B" 1'-7�B'r #I j„i'G F� of =Z � L - LL USE CLASS "B„ CONCRETE THROUGHOUT. OOK. - HZ12p ��4 TOP OF COVER O�OMz fT ¢qv cn _ qA T OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR W a LL L7 ' p p =�Zam r r o II G E E GCS O= �1zWo X x 6m D I - -r I D N4 BAN ODMEL$ AT 12' CENTERS AS DIRECTED BY THE ENDINEER. aUrG� =OZ�m �O ~� �0 ro ect Number: 1 7-18-092 ('n2p - _G O _ I d O x,S.,-ICDI---T1�k �� )v� � ♦1' USE FORMS TO CONSTRUCT THE BOTTOM SLAB. H= ZyJ �(n O6 A A B B �=rzrti S O N H=�2 4,,.-o m rcw� VJ - 0 W z g m p: -n 07 I coo I.- G W G) I IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, S fa O ,_, r LL Q G7 Q Iti LO _ 0 _ I - LL M,,, J S y Z a ADD TO SASE AS SHOWN ON STANDARD NO- 840.00. OO N G n = y 1■ p n i -r O (V _-_--I-_-_ �p�� . '�nD -- - �` 1 z 1"1� - �{�A T CD I--iCc 4 L y Ey O , L F-I K a n _ 1 PROVIDE ALL JUxIN Al 301E 0V6-MI 3'-B" IN DEPTH WITH aTEPa H N Y n r C>' Date: 0 1/ 1 4/20 1 9 I rM �i10 I- - i,i 12" ON CENTENS IN ACCORDANCE RITN STD. N0. 640.BB- WD L__-_-_-_-___- _-_� L_ _ -� RO A, II I I h W Z a" ADJUST THE ST€EL., WNCRETE AND BRICK MASONRY QUANTITIES r z O Z /± r S '--`�{ I� TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS 112" B. SECTION G - G •' r SEE STANDARD 640.54 G SHORTENED AROUND OPENING IN TOP BLAB, ADDITIONAL VARIABLE �� [1'-4W] LIV-1410.d F#' PLAN FORMANLE COVER 8 FRPME l one 6 ' HEIGHT BRICK MASONRY, OPENING IN TOP SLAB.) BOTTOM OF COVER I2" DraWn By: EMIL PLAN OF FRAME ITN C. To C. MAX. DIEON IOFI2 IFE9ESTRUCTURE FROM TOP OF BOTTOM SLAB TO TOP ' R BRICK MAY BE USED A H r 70 ADJUST FRAME & � 1'-7 g" 1 -7 g CAST IRON ® AT TO SURFACE PLAN OF COMER Checked B NRP f= O O _ Ma BAR - y• m'a z PLAN OF GRATING oar � � r' �. LL z o CrOr 2`-3t/4" CAST IRON Li_ ¢ ¢ z - aurLEr PIPE 0 J � f PLAN OF FRAME O -4 1.4 0 F Ca z O W p Cn Re -visions: CO r- _ ❑ °r N = �I I - E DR F 1 " ��; a zo z rrn = 2'-11,�" o 07-2G-1 8 ORIGINAL SUBMITTAL M z o = p -1 INLET PIPE r - SECTION tL A § d z o ,Br,,. y�rr �„ < Q v _ m a B" DOWEL o F- _ TI p 1 �4"., Ls, Q o a = z C-C OR D-D _j QI 10-23-18 PER DEVELOPER z w C_ o SECTION X-X o 0 t7 1„ 1 rr 1 H yr, O O O C y ¢ z z (D 11 1'-S" s w r Z z> a O> ¢ 1 2-1 G-1 8 PER TOWN QE GRANITE QUARRY d (f W D 0 DIMENSIONS AND OUAMTITIES FOR CONCRETE JUNCTION NOXES Q 7 H ID ID m 0 e [] In A O j 5" �2" O DZ 30 O) r- 0 O DIMENSIONS OF BOX AND PIPE RE INF0ACtl1ENT TOP SLAB IN VMD5 TOTAL OUANNIT[E9 9EDUCfE0N5 FOR DNF Q I- 2 z I= 0 1 - 1 4- 1 9 PER TOWN QE GRANITE QUARRY 11.�� + I z {L W IL O / TYPE #1 ilfi O �61' y8" rC` 1�8' F4 PIPE SPAN WIDTH HEIGHT Sets "A" DIMENSIONS IN BOX IMDx AxG ELARS PIPE 0.1-YDG. H H D 1" 7 A, I ��" LL n " LU I I 07 z z I 3'-2" E I I ~ LU J O Z O n - - • " " D A 0 H No. LENGTH E F CUP DOTTON OF IS. nE LEIS. MII1i.Y'W N 11 " x `i� On _4s, As, d I !4�., Rr [/1+ H 2 z EXP. JGIxT SLAB SLAB FT. n C.S... R.C. v H SECTION H-H �4 3 �'4 IF- '4 I m o z H 01i p z �- J Z = m •9^ 12" 2'-0" 2'-0" a'-3" 12 Y-R" 9'-a^ a'-O" O.IGr e. ter 0. 136 2a O. r60 G.OIe e.Oza J z -Z O �+% r 1 C O J 1-ai r O � P •r 1a" 2'"3" 2'-3' 2'•6" 12 3'•0' 3'•3' 3'-3" 0.186 0.19E 0.204 24 0,902 0.023 0.036 (a O `~ �. �t a \ / ALTERNATE O Z z a To 2l/g" -� 2%" z a 3 X e^ iB" z'-6" a'-s" z'-a" Ta a-s" 3'-e" 3'-a" a.az7 o.zzT G.zzz ao oes o.aaa o.o4B 9 �� �` SECTION B-8 z Q O w 24" 3'-0" 3'-0" 3'-3" TB 3'-8" 4'-0' 4'-0" 0.288 0.296 0.269 40 1.434 0.050 0.08E I I W r N N N I I- N N O WB 2'-Olr2" / I MINIMUM WEIGHTS - LB'S. W m 9 1�S FF..2 1 �� 3G" a'-B" a'-s" 3'-9" Te s'-9° 4'-B" a'-6" o.a7s 0.4Ts a.29e 51 Beo O. oez O.lar ' y \ FRAME - 180 a W p O . • -' 3e" a'-D" a'-D" 4'-3" zD a'-R" s'-D" 5'-0^ 0.463 D.a63 ❑.aaa e4 2.341 0.132 0.178 2'-B%" \ L � O a" 'DOWEL 4'-6" 4'-9" 22 5`3" 5'-6" 5'-B" 0. 580 1 0.560 0.370 77 2.078 O.1B0 0.243 % GOVER 120 2'-6'r O 48' 5'-4" 5'-4" W-3" 215 B'-a" 6,4" S'-a" 0.7a3 0.7aa 0.407 111 3.023 0.235 0.317 SECTION A -A I I TOTAL - 300 Sheet Title: 'i 1 J SECTION Y-Y 50." 5'-i0" W-10" 6'-g" 2e 8'-J" s'-10" e'-10" O.BBS a.8B5 a.a44 12G 6.288 0.297 0.407 \ SECTION E - E SECTION F - F Sr' so 7r-1" 7'-0' 1 7'-8" 1 iSh EEI 1 OF 1 rr " 1.042 1.042 0.481 145 --- 6'-B"9'-1" 0.0.5E SHEET 1 OF 1 "84054 �2840.31� YPE 801E l SHEET i OF 1 EROSION 10 CONCRETE JUNCTION BOX CONTROL 9 Drop Inlet Frame and Grates Detail 11 Manhole Frame and Cover Detail DETAILS 5.o SCALE: N.T.S. [REF: NCDOT #840.16] 6"0 SCALE: N.T.S. [REF: NCDOT #840.31 ] 5-o SCALE: N.T.S. [REF: NCDOT #840.54] Sheet No - COPYRIGHT © 2019, AMICUS PARTNERS, PLLC. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND �11111111111111111111500 OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS ADJACENT PROPERTIES REFERENCED FROM A SURVEY CONDUCTED BY CABARRUS COUNTY DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT GIs. PROPERTY DIMENSIONS AND COORIDINATES FOR PROPERTY REFERENCED FROM OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY CABARRUS COUNTY GAS. COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VALID, TRUE COPIES. 6' MAX. WOVEN FILTER FABRIC O I N GENERAL NOTES: 1. FILTER FABRIC FENCE SHALL BE A MINIMUM OF 32" IN WIDTH AND SHALL HAVE A MINIMUM OF 6 LINE WIRES WITH 12" STAY SPACING. 2. WOVEN FILTER FABRIC BE USED WHERE SILT FENCE IS TO REMAIN FOR A PERIOD OF MORE THAN 30 DAYS. 3. STEEL POSTS SHALL BE 5'-0" IN HEIGHT AND BE OF THE SELF -FASTENER ANGLE STEEL TYPE. 4. TURN SILT FENCE UP SLOPE AT ENDS. 5. ORANGE SAFETY FENCE IS REQUIRED AT BACK OF SILT FENCE WHEN GRADING IS ADJACENT TO SWIM BUFFERS, STREAMS OR WETLANDS (REFER TO SWIM BUFFER GUIDELINES). THE COLOR ORANGE IS RESERVED FOR VISUAL IDENTIFICATION OF ENVIRONMENTALLY SENSITIVE AREAS. 6. DRAINAGE AREA CAN NOT BE GREATER THAN 1/4 ACRE PER 100 FT OF FENCE. 7.SLOPE LENGTHS CAN NOT EXCEED CRITERIA SHOWN IN TABLE 6.62A NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. &DO NOT INSTALL SEDIMENT FENCE ACROSS STREAMS, DITCHES, WATERWAYS OR OTHER AREAS OF CONCENTRATED FLOW. A T FjjAKE HARDWARE OLoTH BETWEEN P05T�r, HART, WARE CLOTH AND ',:JLT FENCE NOTE-. TO BE 8WED MININALIN OF 1' STRUCTURAL STONE SHALL BE CLASS -a- 5TDXE FOI{ ERL43Cfa CONTRm ipurrDSE:s, 5E WENT CONTROL STONE SHALL BE M W cR rlp. j 7 sT4r+E, SELT FENCE f ^ A p0sr SE'1IVENT COfEL MIN I MAX, `'' STRUGTI ST17►+ rtY� L�IE•t� flLTC;TlC�1'J'�iv` FFp6}�TVIEkt� SEEDBED REQUIREMENTS: ESTABLISHMENT OF VEGETATION SHOULD NOT BE ATTEMPTED ON SITES THAT ARE UNSUITABLE DUE TO INAPPROPRIATE SOIL TEXTURE (TABLE 6.10A), POOR DRAINAGE, CONCENTRATED OVERLAND FLOW, OR STEEPNESS OF SLOPE UNTIL MEASURES HAVE BEEN TAKEN TO CORRECT THESE PROBLEMS. TO MAINTAIN A GOOD STAND OF VEGETATION, THE SOIL MUST MEET CERTAIN MINIMUM REQUIREMENTS AS A GROWTH MEDIUM. THE EXISTING SOIL SHOULD HAVE THESE CRITERIA: - ENOUGH FINE-GRAINED (SILT AND CLAY) MATERIAL TO MAINTAIN ADEQUATE MOISTURE AND NUTRIENT SUPPLY (AVAILABLE WATER CAPACITY OF AT LEAST 0.05 INCHES WATER TO 1.00 INCH OF SOIL). - SUFFICIENT PORE SPACE TO PERMIT ROOT PENETRATION. - SUFFCENT DEPTH OF SOIL TO PROVIDE AN ADEQUATE ROOT ZONE. THE DEPTH TO ROCK OR IMPERMEABLE LAYERS SUCH AS HARDPANS SHOULD BE 12 INCHES OR MORE, EXCEPT ON SLOPES STEEPER THAT 2:1 WHERE THE ADDITION OF SOIL IS NOT FEASIBLE. - A FAVORABLE H RANGE FOR PLANT GROWTH USUALLY 6.0 - 8.5. - FREE FROM LARGE ROOTS, BRANCHES, STONES , LARGE CLODS OF EARTH, OR TRASH OF ANY KIND. CLODS AND STONES MAY BE LEFT ON SLOPES STEEPER THAN 3:1 IF THEY ARE HYDROSEEDED. IF ANY OF THE ABOVE CRITERIA ARE NOT MET - I.E. IF EXISTING SOIL IS TOO COARSE, DENSE, SHALLOW, OR ACIDIC TO FOSTER VEGETATION - SPECIAL AMENDMENTS ARE REQUIRED. THE SOIL CONDITIONERS DESCRIBED BELOW MAY BE BENEFICIAL OR, PERFERABLY, TOPSOIL MAY BE APPLIED. SEEDBED PREPARATION: FILL SLOPES (PERMANENT SEEDING) - FOR FILL SLOPES 3:1 OR STEEPER: 1. LEAVE THE LAST 4-6 INCHES OF FILL LOOSE AND UNCOMPACTED, ALLOWING ROCKS, ROOTS, LARGE CLODS AND OTHER DEBRIS TO REMAIN ON THE SLOPE. 2. ROUGHEN SLOPE FACES BY MAKING GROOVES 2-3 INCHES DEEP, PERPINDICULAR TO THE SLOPE. 3. SPREAD LIME EVENLY OVER SLOPES AT RATES RECOMMENDED BY SOIL TESTS. FILL SLOPES (TEMPORARY SEEDING) - FOR FILL SLOPES 3:1 OR STEEPER: 1. LEAVE A LOOSE, UNCOMPACTED SURFACE. REMOVE LARGE CLODS, ROCKS, AND DEBRIS WHICH MIGHT HOLD NETTING ABOVE THE SURFACE. 2. SPREAD LIME AND FERTILIZER EVENLY AT RATES RECOMMENDED BY SOIL TESTS. 3. INCORPORATE AMENDMENTS BY ROUGHENING OR GROOVING SOIL SURFACE ON THE CONTOUR. FOR HIGH -MAINTENANCE TURF: 1. REMOVE ROCKS AND DEBRIS THAT COULD INTERFERE WITH TILLAGE AND THE PRODUCTION OF A UNIFORM SEEDBED. 2. APPLY LIME AND FERTILIZER AT RATES RECOMMENDED BY SOIL TESTS; SPREAD EVENLY AND INCORPORATE TO A DEPTH OF 2-4" WITH A FARM DISK OR CHISEL PLOW. 3. LOOSEN THE SUBGRADE IMMEDIATELY PRIOR TO SPREADING TOPSOIL BY DISKING OR SCARIFYING TO A DEPTH OF AT LEAST 2 INCHES. 4. SPREAD TOPSOIL TO A DEPTH OF 2-4 INCHES AND CULTIPACK. 5. DISK OR HARROW AND RAKE TO PRODUCE A UNIFORM AND WELL -PULVERIZED SURFACE. 6. LOOSEN SURFACE JUST PRIOR TO APPLYING SEED. FOR GENTLE OR FLAT SLOPES WHERE TOPSOIL IS NOT USED: 1. REMOVE ROCKS AND DEBRIS. 2. APPLY LIME AND FERTILIZER AT RATES RECOMMENDED BY SOIL TESTS; SPREAD EVENLY AND INCORPORATE INTO THE TOP 6" WITH DISK, CHISEL PLOW, OR ROTARY TILLER. 3. BREAK UP LARGE CLODS AND RAKE INTO A LOOSE, UNIFORM SEEDBED. 4. RAKE TO LOOSEN SURFACE JUST PRIOR TO APPLYING SEED. NOTE: LIME AND FERTILIZER NEEDS SHOULD BE DETERMINED BY SOIL TESTS. SOIL TESTING IS PERFORMED FREE OF CHARGE BY THE NORTH CAROLINA DEPARTMENT OF AGRICULTURE (NCDA) SOIL TESTING LABORATORY. DIRECTIONS, SAMPLE CARTONS, AND INFORMATION SHEETS ARE AVAILABLE THROUGH COUNTY AGRICULTURAL EXTENSION OFFICES OR FROM NCDA. ALLOW 1-6 WEEKS FOR SAMPLE TURN -AROUND SO PLAN WELL IN ADVANCE OF FINAL GRADING. WHEN SOIL TEST ARE NOT AVAILABLE, FOLLOW RATES SUGGESTED ON THE INDIVIDUAL SPECIFICATION SHEET FOR THE SEEDING MIX CHOSEN (TABLES 6.11C THROUGH 6.11V). APPLICATION RATES USUALLY FALL INTO THE FOLLOWING RANGES: - GROUND AGRICULTURAL LIMESTONE: LIGHT -TEXTURED, SANDY SOILS: 1 TO 1-1/2 TONS/ACRE HEAVY -TEXTURED, CLAYEY SOILS: 2-3 TONS/ACRE - FERTILIZER: GRASSES: 800-1,200 LB/ACRE OF 10-10-10 (OR THE EQUIVALENT) GRASS -LEGUME MIXTURES: 800-1,200 LB/ACRE OF 5-10-10 (OR THE EQUIVALENT) 5 5.1 Seeding Specifications Ref: NCDENR COPYRIGHT© 2019, AMICUS PARTNERS, PLLC. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VALID, TRUE COPIES. STEEL POST z � w FILTER FABRIC a - JU °U FLO rtW 4" MAINTENANCE NOTES: 1. FILTER BARRIERS SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 2. SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL IS NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS REACH HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED. 1 Silt Fence Detail Ref: NCDENR #6.62.5 !ILT Fericu GENERAL NOTES: 1. STONE OUTLETS SHOULD BE PLACED IN THE LOW-LYING AREAS OF SILT FENCING, BASED ON FIELD CONDITIONS. 2. MAINTENANCE - FRESHEN STONE WHEN SEDIMENT ACCUMULATION IS 6 INCHES OR AS NEEDED. Stone Outlet Detail 5.1 Ref: NCDENR Seeding Mixture Rate (lb/acL Tall Fescue 200 (4-5 lb/1,000 sq. ft.) Nurse Plants: Between May 1 and Aug. 15 add 15 lb/acre Sudangrass or 10 lb/acre German Millet. Before May 1, or After Aug. 15, add 40 lb/acre rye (grain). Seeding Dates: Best: Aug. 25 - Oct. Possible: Feb. - Aug. Avoid seeding from Nov. to Jan. If seeding must be done at this time, add 40 lb/acre rye grain and use a channel lining that offers maximum protection. Soil Amendments: Apply lime and fertilizer according to soil tests, or apply 4,000 lb/acre ground agricultural limestone and 1,000 lb/acre 10-10-10 fertilizer. Operate tillage equipment across the waterway. Mulch: Use jute, erosion control matting, or other effective channel lining material to cover the bottom of the channels and ditches, and staple securely. The lining should extend above the highest calculated depth of flow. On channel side slopes above this height, and in drainages not requiring temporary linings, apply 4,000 lb/acre grain straw and anchor straw by stapling netting over the top. Mulch and anchoring material must not be allowed to wash down slopes where they can clog drainage devices. Maintenance: Inspect and repair mulch frequently. Refertilize in late winter of the following year; use soil tests or apply 150 lb/acre 10-10-10. Mow regularly to a height of 2-4 inches. REFERENCE: NORTH CAROUNA EROSION AND SEDIMENT CONTROL MANUAL Seeding Mixture Rate (lb/acre) Tall Fescue 200 (4-5 lb/1,000 sq. ft.) Sericea Lespedeza 30 (0.7-0.8 lb/1,000 sq. ft.) Kobe Lespedeza 10 (0.2-0.3 lb/1,000 sq. ft.) Seeding Notes: 1. In Eastern Piedmont add 251b/acre Pensacola Bahiagrass or 10 lb/acre common Bermudagrass. Use common Bermudagrass only where it is unlikely to become a pest. 2. After Aug. 15 use unscarified sercia seed. 3. Where a neat appearance is desired, omit sercia and substitute 40 lb/acre Bohiogross or 15 lb/acre hulled Bermudagrass. 4. To extend spring seeding dates into June, add 15 lb/acre hulled Bermudagrass. However, it is perferable to seed temporary cover and seed Fescue in September. Nurse Plants: Between May 1 and Aug. 15 add 15 lb/acre Sudangrass or 10 lb/acre German Millet. Before May 1, or After Aug. 15, add 40 lb/acre rye (grain). Seeding Dates: Best: Fall (Aug. 25 - Sep. 15), Late Winter (Feb. 15 - Mar. 21) Possible: Fall (Aug. 20 - Oct. 25), Late Winter (Feb. 1 - Apr. 15) Fall is best for Tall Fescue and late winter for Iespedezas. Overseeding of Kobe Lespedeza over fall -seeded Tall Fescue is very effective. Use unhulled Bermudagrass seed in fall. Soil Amendments: Apply lime and fertilizer according to soil tests, or apply 4,000 lb/acre ground agricultural limestone and 1,000 lb/acre 10-10-10 fertilizer. Mulch: Apply 4,000-5,000 lb/acre grain straw or equivalent cover or another suitable mulching material. Anchor mulch by tacking with asphalt, roving, or netting. Netting is the pre- ferred anchoring method on steep slopes. Maintenance: Inspect and repair mulch frequently. Refertilize in the second year unless growth is fully adequate. Mow regularly to a height of 2-4 inches in necessary areas. Other areas may be mowed once or twice a year, but is not necessary. REFERENCE: NORTH CAROUNA EROSION AND SEDIMENT CONTROL MANUAL REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND ADJACENT PROPERTIES REFERENCED FROM A SURVEY CONDUCTED BY CABARRUS COUNTY GIs. PROPERTY DIMENSIONS AND COORIDINATES FOR PROPERTY REFERENCED FROM CABARRUS COUNTY GIs. 2. CHECK DAMS MAY BE USED IN SLOPING DITCHES OR CHANNELS TO SLOW VELOCITY OR TO CREATE SEDIMENT TRAPS. 3. ENSURE THAT MAXIMUM SPACING BETWEEN DAMS PLACES THE TOE OF THE UPSTREAM DAM AT THE SAME ELEVATION AS THE DOWNSTREAM DAM (SEE DIAGRAM BELOW). aISs ■ PoP A MAXIMUM SPACING B - _ =1 i_IIJII_lll_Ill_Ill- a ,_ _ A AND B ARE AT EQUAL ELEVATIONS CROSS SECTION 1•-*• MN. 1111�1I L r MN. II IJII JH� m"'ill 0�-13 MIS„ _ Ili "'mom„ ti,illr� nuEM cLont UI=INgll�ll=1" ul==llrwul1 ul= "IdH$Ill�i lln ulni_ITiyr�Ul�l_UI_UIs PLAN Temporary Rock Check Dam 5.1 Ref: MCLDS Standard #30.10 FILL SLOPE Temporary Silt Ditch 5.1 Ref: MCLDS Standard #30.05 2' M17 FINISH G�DE NATURAL GROUND DW IAX MHIER BERM SILT FENCE (SEE NOTE 2) NOTE: BOTTOM WIDTH OF CHANNEL = 1.0 FT 1. DITCH SHOULD HAVE LONGITUDINAL SLOPE OF 1% UNLESS CHECK DAMS ARE PROVIDED. MIN. HEIGHT OF CHANNEL = 2.0 FT 2. SILT FENCE MAY BE REQUIRED BEHIND BERM *36" MIN. SPACING TYP. KEY/ANCHOR MATERIAL AT TOP OF SLOPE. 6" OVERLAP IN SLICE NON-WOVEN GEOTEXTILE FILTER CLOTH FABRIC 4' ABOVE SOURCE WATER. WATER TABLE J.I NOTES 1. LAY BLANKETS LOOSELY AND STAKE OR STAPLE TO MAINTAIN DIRECT CONTACT WITH THE SOIL DO NOT STRETCH. 2. * DIMENSIONS SHOWN ARE MINIMUM, MANUFACTURED PRODUCTS MAY HAVE ADDITIONAL REQUIREMENTS THAT MUST BE MET. 3. SLOPE SURFACE SHALL BE FREE OF ROCKS, SOIL CLODS, STICKS, GRASS. MAT/BLANKETS SHALL HAVE GOOD SOIL CONTACT. KEY/ANCHOR MATERIAL TO TOE OF SLOPE. n Embankment Matting Detail Ref: MCLDS Standard #30.20 SEEDING: FOR PERMANENT SEEDING FILL SLOPES STEEEPER THAN 3:1, USE HYDRAULIC SEEDING EQUIPMENT TO APPLY SEED AND FERTILIZER, A WOOD MULCH FIBER AT 45 LB/1,000 SQ. FT., AND MULCH TACTIFER. FOR GENTLE TO FLAT SLOPES OR TEMPORARY SEEDING, BROADCAST SEED AT THE RECOMMENDED RATE WITH A CYCLONE SEEDER, DROP SPREADER, OR CULTIPACK SEEDER. RAKE SEED INTO THE SOIL AND LIGHTLY PACK TO ESTABLISH GOOD CONTACT. USE CERTIFIED SEED FOR PERMANENT SEEDING WHENEVER POSSIBLE. CERTIFIED SEED IS INSPECTED BY THE NORTH CAROLINA CROP IMPROVEMENT ASSOCIATION. IT MEETS PUBLISHED NORTH CAROLINA STANDARDS AND SHOULD BEAR AN OFFICIAL "CERTIFIED SEED" LABEL. LABELING OF NON -CERTIFIED SEED IS ALSO REQUIRED BY LAY. LABELS CONTAIN IMPORTANT INFORMATION ON SEED PURITY, GERMINATION, AND PRESENCE OF WOOD SEEDS. SEEDS MUST MEET STATE STANDARDS FOR CONTENT AND NOXIOUS WEEDS. DO NOT ACCEPT SEED CONTAINING "PROHIBITED" NOXIOUS WEED SEED. Lt9�97�1��9AP�IIReiylblbl�rl/_il��l_1�1�:�9��r]IR� FOR PERMANENT SEEDING FILL SLOPES 3:1 OR GREATER: - IN MID -SUMMER, LATE FALL, OR WINTER, APPLY 100 LB/1000 SQ. FT. GRAIN STRAW, COVER WITH NETTING AND STAPLE TO THE SLOPE. IN SPRING OR EARLY FALL USE 45 LB/1000 SQ. FT. WOOD FIBER IN A HYDROSEEDER SLURRY. FOR HIGH -MAINTENANCE VEGETATION AND TEMPORARY SEEDING: - APPLY 90 LB/1000 SQ. FT. (4,000 LB/ACRE) GRAIN STRAW AND TACK WITH 0.1 GAL/SQ. YD. ASPHALT (11 GAL/1000 SQ. FT.) FOR GRASS -LINED CHANNELS: - INSTALL RECOMMENDED EROSION CONTROL MAT IN THE CHANNEL, EXTEND UP THE CHANNEL BANKS TO THE HIGHEST CALCULATED DEPTH OF FLOW (SEE GRASS -LINED CHANNEL DETAIL), AND SECURE AND ANCHOR. MAINTENANCE: GENERALLY, A STAND OF VEGETATION CANNOT BE DETERMINED TO BE FULLY ESTABLISHED UNTIL SOIL COVER HAS BEEN MAINTAINED FOR ONE FULL YEAR FROM PLANTING, INSPECT SEEDED AREAS FOR FAILURE AND MAKE NECESSARY REPAIRS AND RESEEDINGS WITHIN THE SAME SEASON, IF POSSIBLE. RESEEDING - IF A STAND HAS INADEQUATE COVER, RE-EVALUATE CHOICE OF PLANT MATERIALS AND QUANTITIES OF LIME AND FERTILIZER. RE-ESTABLISH THE STAND AFTER SEEDBED PREPARATION OR OVERSEED THE STAND. CONSIDER SEEDING TEMPORARY, ANNUAL SPECIES IF THE TIME OF YEAR IS NOT APPROPRIATE FOR PERMANENT SEEDING. IF VEGETATION FAILS TO GROW, SOIL MUST BE TESTED TO DETERMINE IF ACIDITY OR NUTRIENT IMBALANCE IS RESPONSIBLE. FERTILIZATION - ON THE TYPICAL DISTURBED SITE, FULL ESTABLISHMENT USUALLY REQUIRES REFERTILIZATION IN THE SECOND GROWING SEASON. FINE TURF REQUIRES ANNUAL MAINTENANCE FERTILIZATION. USE SOIL TESTS IF POSSIBLE OR FOLLOW THE GUIDELINES GIVEN FOR THE SPECIFIC SEEDING MIXTURE. FOR GENTLE SLOPES Seeding Mixture Rate (lb/acre)_ Tall Fescue 250 (4-5 lb/1,000 sq. ft.) Nurse Plants: Between May 1 and Aug. 15 add 35 lb/acre German Millet. Before May 1, or After Aug. 15, add 40 lb/acre Rye (Grain). Seeding Dates: Best: Aug. 25 - Oct. Possible: Feb. - Aug. Avoid seeding from Nov. to Jan. If seeding must be done at this time, add 40 lb/acre rye grain. Soil Amendments: Apply lime and fertilizer according to soil tests, or apply 4,000 lb/acre ground agricultural limestone and 1,000 lb/acre 10-10-10 fertilizer. Mulch: Apply 4,000-5,000 lb/acre grain straw or equivalent cover or another suitable mulching material. Maintenance: Inspect and repair mulch frequently. Topdress with 10-10-10 fertilizer if growth is not fully adequate. Mow regularly to a height of 2-4 inches. 5 -k: ,k 6iL =1kli ,k1F,E-7 IC- =LisZK• _ 51A0 FL'{-?• C-0 VtTE;h'•L hn10 tK A.;.;II I'xlr, I I1 !rlIIII - b�:Yv I III .• 1.,.;; JP v04f;Fr= E L1r010rLEV.z _ _ _CTICN 1 5Ar' -C S•s� LI k_ a1-WL.' I J =ER 91-.-E' 5 11' kilkl YLF. r r 1.{_ yy = lv I 5 I• € E y zES x- ST=E_'�rIR= 1 GTr'�PLC - P1�-luwrrl - 7LAN �'� STRk' i =A_= DETAIL kF,T TL SC,+LE I Yr': I Y PL "AlUOV L GRAUL' Vr l I r t; I I OW BALL t; r 4- o e e NOTES AJCTU•%. L•%YC.L--•0 RE :=TE;1JINEC IN THE FIEL-- c, A I L'h-%-;I I::IJ I ',-K LJ -A I-%LL CI_ Iw: 1 A-LL-, I ITIIIw 0;'rj= T•1_ T[\1P;;F{y41' -A.CILI I Y. r Rj �. _I-0Ir L a lr i_l I1} r'rIk 114U I I L V1JjI4.1j4 '.-1JwL::.L I L 7,!1.2110. T F.'-vIJ-IEE S+-LL RE 9Eh1.05•ED =ROh1--° SITE :'IF THE 'r nRK rN"/-.{SP.7j:.F., %)- nR R=r.".:l F",, !.1 •{ 4:': UE-1"E•.i'-&-} . vF•' L:11.4.L: v1J`� }.i,a l Uwp.�h1,.= AUS=D E%' THE RE'200%_ 017 --I9 TE VPOPAF;w }ON' BETE irA3Hf I.T F ,.^.I• I-IFr nibl 13F Fk•..KFp . =n. T=rAlPF'. �w •: Ih_ILI�L.y (, •'ItL;Lk _I�:;:rF;l`J, A � II -I - - Y H I - =1 I - -I I - x � `� � I1=11_ A I „III_I B G/ W `W - LINING MUST BE ANCHORED CROSS SECTION VIEW A B / C CHANNELS SHALL BE LINED WITH NORTH AMERICAN GREEN EROSION CONTROL LINING OR SYNTHETIC INDUSTRIES TURF REINFORCEMENT MATS OR ENGINEER APPROVED EQUIVALENT. (SEE DETAIL 8/5.3 FOR INSTALLATION SPECIFICATIONS.) CHANNEL TYPE PERMANENT LINING REQUIRED PERMANENT LINING MATERIAL CHANNEL HEIGHT H (ft) SIDE SLOPE A B W Y X TD-1 NO DS75 1.00 3 3 3.50 3.50 1.0 DL-2 NO DS75 2.00 3 3 4.00 4.00 2.0 GENERAL NOTES: 1. AREA IN AND AROUND CHANNEL SHALL BE CLEARED, GRUBBED, AND STRIPPED OF ANY VEGETATION AND ROOT MAT. COMPACT LOOSE MATERIAL IN AND AROUND CHANNEL SO THAT SURFACE WATER MAY ENTER AND FLOW FREELY. 2. APPLY LIME, FERTILIZER, AND SEED PRIOR TO PLACEMENT OF EROSION CONTROL MATTING. 3. LAY EROSION CONTROL MATTING ON THE TOP OF THE CHANNEL AND UNROLL IT DOWN THE GRADE. ALLOW MATTING TO LAY LOOSELY WITHOUT WRINKLES. 4. JOIN TWO STRIPS OF MATTING BY OVERLAPPING 4 INCHES AND STAPLING EVERY TWELVE INCHES ALONG THE OVERLAP. ALONG THE UPPER EDGE OF THE CHANNEL, BURY THE MATTING IN A TRENCH NO LESS THAN 6 INCHES DEEP AND COMPACT SOIL OVERTOP OF IT. 5. STAPLE THE MATTING EVERY TWELVE INCHES ALONG THE TOP EDGES AND EVERY THREE FEET ACROSS THE SLOPE AND ALONG THE MIDDLE. STAPLES SHOULD BE U-SHAPED AND 4 INCHES TO 6 ICHES LONG. 6. INSPECT THE CHANNEL WEEKLY OR AFTER EVERY RAINFALL EVENT UNTIL VEGETATION IS FIRMLY ESTABLISHED. SHOULD EROSION OCCUR, REMOVE ANY SEDIMENT AND REPAIR WITH MATTING OR MULCH SO THE DESIGNED FLOW CAPACITY OF THE CHANNEL IS NOT ALTERED OR EFFECTED. Grass Lined Channel Detail 5.1 Ref: North American Green =_r�is/alk�,�ar1 it .. c y _v I_ SEI A: A. hCy- lr-C-*� E-EFiH 13 Lh 4C fr hclin -4f,ki- ki:GUR-L'e =AST=AE1ARCAIND � ti -DECTION 9-9 F%ITIr;- r--Rlki-Tr-v kiC--0 -sv+,..E �171.111� Concrete Washout 5.1 N TS rvC-_Y 1C-b F W1 END OF FLARED SECTION 0 % SLOPE -APRONS MUST BE FLAT 5!hDSs�C, PLA.N wDIT TIZ S�_,A_E SERIA FE 'BEL011� R41=' ax•a •a:ural FFs'1dt wi r I I :Y.W.L1 PLANKS ...... ,-... .. .._.._..,.._.._.. ._. 111 00 1' MIN. II II IIP 1' MIN. 1 1 -6" FILTER FABRIC LAP (IF NEEDED) ELEVATION NAIUKAL UKAUL MINIMUM H=2/3 PIPE DIAMETER SECTION B- B THICKNESS) ALL RIPRAP SHALL BE CLASS B OR ENGINEER APPROVED. APRON D(FT) La(FT) W1(FT) W2(FT) T(FT) D50(IN) DMAX(IN) H (IN) FES-1 1.25 6.0 3.75 7.25 0.75 4.0 6.0 15.0 FES-2 2.00 9.0 6.0 8.0 0.75 4.0 6.0 24.0 FES-3 (2)1.25 9.0 7.5 11.5 .75 4.0 6.0 24.0 FES-4 1.25 6.0 3.75 7.25 1.25 6.0 9.0 15.0 * D = diameter of pipe ** d50 (see fig 8.06 a&b "NC SEDIMENT AND EROSION CONTROL MANUAL" dmax = 1.5 x d50 T = 1.5 X dmax. Riprap Apron Detail 5.1 Ref: MCLDS Standard #20.23 Firm License # P-1191 7140 Weddinton Road Suite 140 Concord, NC 28027 Civil Site Design Low Impact Development Small -Scale Building Design Telephone: 704.573.1621 Facsimile: 704.248.7951 Seals: \\\ N CA/� 0 ` Q SEAL =z g 032006 0 a:-` Jj� 01-14- 2019 0 Z < C'_ o -1 Z Z I•f1 - Froject Number: 17-18-092 Date: 01 / 14/20 1 9 Drawn ,By: , EMIL Checked By: NRF Revisions: 07-2G-18 ORIGINAL SUBMITTAL 0 10-23-18 PER DEVELOPER 1 2- I G-1 8 FEK TOWN Off CRANiTE QUARRY O 1 -1 4-1 9 FEK TOWN Off CRANiTE QUARRY L � Sheet Title: EROSION CONTROL DETAILS Sheet No: C�5 ■ 1 Pipe InletID From (Up) To (Dn) Inlet Drainage Area Runoff Coeff IncrQ TotalRunoff FlowRate VelAve Line Size Line Length InvertUp InvertDn LineSlope Grnd/Rim ElevUp Grnd/Rim Elev Dn PIPE CLASS (in/hr) (ac) (C) (cfs) (cfs) (cfs) (ft/s) (in) (ft) (ft) (ft) (%) (ft) (ft) HEILIG ROAD BUILDING EXP Pi DI1 DI1 FES1 7.26 0.56 0.30 1.22 1.22 1.22 5.40 15.00 165.00 818.00 813.00 3.00 824.00 813.00 RCP III P2 FES1 FES1 D12 1 7.26 0.76 0.30 1.66 2.88 2.88 3.48 24.00 60.00 812.94 812.62 0.50 812.94 815.00 RCP III P3 D12 D12 JB3A 1 7.26 0.54 0.75 2.94 5.82 5.82 4.78 24.00 96.00 811.61 810.94 0.70 815.00 819.00 RCP III P4A JB3A JB3A JB3B 7.26- - - 5.82 5.82 4.78 24.00 282.00 810.94 808.97 0.70 819.00 814.00 RCP III P413 JB3B JB3B RISER 7.26- - - 5.82 5.82 6.99 24.00 23.00 808.97 808.50 2.00 814.00 813.00 RCP III P5 RISER RISER FES2 7.26 1.50 - 1.03 6.85 6.85 4.99 24.00 40.00 808.50 808.22 0.70 813.00 808.22 RCP III EX. P6 TD2 TD2 FES3 7.26 0.44 0.75 2.40 9.25 9.25 5.00 (2) 15.00 71.00 806.90 806.46 0.60 806.90 806.46 RCP III P7 D14 I D14 JB5 1 7.26 0.44 0.90 2.87 2.87 2.87 4.59 15.00 40.00 808.00 807.60 1.00 814.00 814.75 RCP III rP8 JB5 jJB5 I FES4 I - I - I - I - 1 2.871 2.871 8.16 18.00 95.00 807.60 803.00 4.841 814.751 803.001 RCP III .000 < / '0\0 EA wdLL� MAX E 8 L NOTE TO G.C. \ 1 c I 7// // FOUNDATION AND RETAINING // WALLS MUST BE APPROVED BY 1 THE ROWAN COUNTY BUILDING �' I �/ / INSPECTIONS DEPARTMENTpo I / •/> /� \ ��S\ \ .5 089.7NI F.FLOOR,819.76 - \ / 509 DUKE POWER ESMT. / ' // (D. B. 782 PG. 904)_ B3B \ / 4E \�\\ N /,C L / ES2 \ I \ F.FL OR N IV D14 805.00 I 46" / I I of co LEGEND SUBJECT PROPERTY BOUNDARY EXISTING SANITARY SEWER EASMENT EXISTING 68' DUKE POWER R/W / .... - - EXISTING 50' DUKE POWER EASMENT - ADJACENT PROPERTY X X EXISTING FENCE - PROPOSED BUILDING EXPANSION 70.a TOPOGRAPHY PROPOSED FENCE DRAINAGE AREA 1 I '?0 GRAPHIC SCALE 1 1 1 TOP OF POND 60 0 30 60 120 ROUGHED IN / iB00.00- COPYRIGHT© 2019, AMICUS PARTNERS, PLLC. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS ADJACENT PROPERTIES REFERENCED FROM A SURVEY CONDUCTED BY CABARRUS COUNTY DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT GIS. PROPERTY DIMENSIONS AND COORIDINATES FOR PROPERTY REFERENCED FROM OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY CABARRUS COUNTY GIS. COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VALID, TRUE COPIES. V /11 YV 1 IL 1 LI \ VI - I (SEE DETAIL ON THIS SHEET) SAND FILTERS SF-1 PLAN VIEW SIDE SLOPES OF SF AREA TO BE 3:1 AND MUST BE CLEAN, WASHED STONE TO PREVENT CONTAMINATION OF SAND IN FILTER 820 810 DAYVAI ELEV 800 10—YR, 24—HP WATEI 2—YR, 2 1ST I 0+00 1 INCH = 10 FEET VERTICAL GRAPHIC SCALE (PROFILE VIEW) 1 INCH = 10 FEET 10 0 5 10 20 GRAPHIC SCALE (PLAN VIEW) 30 0 15 30 60 COPYRIGHT © 2019 AMICUS PARTNERS, PLLC. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS OF THIS DOCUMENT, OR ADDITIONS OR DELETIONS TO THIS REFERENCE: ALL PARCEL AND BOUNDARY INFORMATION FOR THIS PROPERTY AND DOCUMENT, IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT ADJACENT PROPERTIES, PROPERTY DIMENSIONS, AND COORIDINATES REFERENCED FROM OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY CABARRUS COUNTY GIs. COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY THE ENGINEER SHALL BE CONSIDERED TO BE VALID, TRUE COPIES. SAND FILTER MEDIA ;TED. CLEAN WASHED )SED TO PREVENT LARGE CLOGGING THE SYSTEM. WASHED SAND BASE OR A HARD SURFACE SUCH AS RIVER ROCK PERFORATED PIPE UNDERDRAIN COLLECTION SYSTEM —III— i—III THE UNDERDRAIN COLLECTION SYSTEM SHOULD BE 11 DO NOT COMPACT BOTTOM EQUIPPED WITH 6-INCH MINIMUM PERFORATED SCHEDULE 40 SCARIFY BOTTOM A MINIMUM OR STRONGER PVC PIPE.PERFORATIONS SHALL BE PER OF 3-FEET AASHTO M278 FOR PVC PIPE,OR BE 3/8-INCH IN DIAMETER SPACED 3 INCHES ON CENTER ALONG TYPICAL SECTION 4 LONGITUDINAL ROWS THAT ARE SPACED 90° APART. NOT TO SCALE THE PIPES SHALL HAVE A MINIMUM SLOPE OF 0.5% AND A MAXIMUM SPACING OF 10 FEET ON CENTER. SAND FILTRATION DETAIL REF: CHARLOTTE- MECKLENBURG BMP DESIGN MANUAL (REVISED JULY 2013) THE TOP OF THE SAND FILTER MEDIA MUST BE PROTECTED. CLEAN WASHED STONE MUST BE USED TO PREVENT LARGE FLOATABLES FROM CLOGGING THE SYSTEM. 1 +00 THE UNDERDRAIN COLLECTION SYSTEM SHOULD BE EQUIPPED WITH 6-INCH MINIMUM PERFORATED SCHEDULE 40 OR STRONGER PVC PIPE. PERFORATIONS SHALL BE PER AASHTO M278 FOR PVC PIPE, AASHTO M252 THE PIPES SHALL HAVE A MINIMUM SLOPE OF 0.5% AND A MAXIMUM SPACING OF 10 FEET ON CENTER. WATERTIGHT JOINT AT RISER CONNECTION 18" REINFORCED CONCRETE PIPE (TO FES-2) INLET INVERT ELEV. = 810.50 FT OUTLET INVERT ELEV. = 810.00 FT LENGTH = 40.00 FT SLOPE = 1.25% TRASH RACK NOTES: EACH TRASH RACK IS TO BE CONSTRUCTED OF #3 REBAR, MUST BE GALVANIZED PRIOR TO FINAL ASSEMBLY. OPENINGS ARE TO BE NO MORE THAN 6" SQUARE. THE ORIFICE TRASH RACKS ARE TO BE ASSEMBLED IN ONE PIECE, AND THE TOP TRASH RACK IS TO BE ASSEMBLED IN 4 SEPARATE PIECES AND BOLTED (NOT WELDED) FOR FINAL ASSEMBLY. TRASH RACK SHALL HAVE A HINGED PANEL FOR WORKER ACCESS. (SEE ABOVE DETAIL) CONSTRUCTION GUIDELINES FOR SAND FILTRATION BASIN SPECIFICATION/TEST METHOD SIZE NOTES MATERIAL Sand substitutions such as Diabase and ASTM-C-144 or Graystone #10 are not acceptable. No ASTM-C-33 concrete sand 0.02" to 0.04" calcium or dolomitic sand substitutions are Sand acceptable. No "rock dust" can be used for sand. Ash content < 15%, The material must be reed -sedge humic peat, pH range: 5.2 to 4.9, n/a shredded, uncompacted, uniform and clean. Loose bulk density (For open and sand filter only). Peat Underlain Gravel blue stone, double washed, #57 stone 0.5" to 1.5" 4" min. over underdrain and max of 12" total Must maintain 125 gpm/ft^2 flow rate. Note: a 0.08" thick Geotextile Fabric MIRAFI 140 OR EQUAL 4" pea gravel layer may be substituted for equivalent opening (if required) geotextiles meant to "separate" sand filter size of #80 sieve layers. ASTM-D-4833 (Thickness) ASTM-D-412 (Tensile strength 1,100 lb, Impermeable Liner P elongation 200 percent) Liner to be ultraviolet -resistant. A geotextile 30 mil thickness fabric should be used to protect the liner from ASTM-D-624 (tear resistance - 150 lb/in) puncture. ASTM-D-471 (water absorption: +8 to 2% mass) Min. 6" perforated Scheduled 40 3/8" perf. @ 3" O/C along 4 longitudinal rows that are Underlain Piping AASHTO-M-278 (PVC) or stronger PVC or double spaced 90 degrees apart. Pipes shall have a min. slope AASHTO-M-252 (HDPE) wall HDPE of 0% and max spacing of 10' O.C. On -site testing of poured -in -place concrete required: 28-day strength and slump test; all Concrete (cast -in - Fe=3,500 psi; normal weight, concrete design (cast -in -place or pre -cast) not place) air -entrained; reinforced to meet ASTM-615-69 n/a using previously approved state or local standards requires design drawings sealed and approved by a licensed, professional structural engineer. Concrete (pre -cast) Per pre -cast concrete manafacturer n/a Non-rebar steel ASTM A-36 n/a REFERENCES: MANUAL OF STOPRMWATEPR BEST MANAGEMENT PRACTICES; NORTH CAPROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES TOWN OF HUNTEPSVILLE WATER QUALITY DESIGN MANUAL (JUNE 2013 EDITION) CHARLOTTE-M ECKLENBUFG BMP DESIGN MANUAL (REVISED JULY 201 3) ADMINISTRATION MANUAL FOR IMPLEMENTATION OF THE POST -CONSTRUCTION STORM WATER ORDINANCE (REVISED JUNE 2013) SAND FILTER MAINTENANCE TASKS AND SCHEDULE TASK SCHEDULE INSPECT BANKS AND SURROUNDING DRAINAGE AREAS FOR EROSION AND STABILIZE IF NECESSARY MONTHLY STREET SWEEP PARKING LOT QUARTERLY TRASH REMOVAL MONTHLY INSPECT OUTLET FOR OBSTRUCTIONS MONTHLY INSPECT FOR CLOGGING MONTHLY INSPECT INLET GRATES MONTHLY SKIM SAND MEDIA YEARLY PUMP OIL AND GRIT FROM SEDIMENTATION CHAMBER YEARLY OR AT 50% FULL REPLACE SAND MEDIA AS NEEDED (EXPECT 3 YEARS) GRA55ED SAND FILTER MOW BASIN TO RECOMMENDED HEIGHT IN ALTERNATING PATTERNS TO PREVENT COMPACTION AND PREVENT WEED GROWTH. BAG CLIPPINGS TO PREVENT THATCH BUILT -UP - WEEKLY TO BI-WEEKLY DURING THE GROWIN SEASON, AS NEEDED OTHER SEASONS LIGHT FERTILIZING TO ESTABLISH HEALTHY ROOTS ONLY DURING THE FIRST 2 YEARS AERATE AND DETHATCH BASIN FLOOR EVERY 2 YEARS NOTE: NO SOD/GRASS IS TO BE PLACED ON TOP OF SAND FILTER. REFERENCE TO GRASS MAINTENANCE IS FOR ALL AREAS OUTSIDE THE SAND FILTER . SAND FILTER TO BE PROTECTED WITH A CLEAN, WASHED STONE ON TOP OF SAND. CLEANOUTS OF 6-INCH SOLID PVC MUST BE PROVIDED FOR EVERY 50 LINEAR FEET OF UNDERDRAIN, AT ALL BENDS, AND ENDS OF THE SYSTEM FOR MAINTENANCE PURPOSES. THE TOP OF THE CLEANOUTS SHOULD EXTEND 6 INCHES ABOVE THE TOP OF FILTER AND HAVE A WATERTIGHT, VANDAL PROOF CAP. AT LEAST ONE CLEANOUT SHALL BE INSTALLED AS AN EMERGENCY DRAIN THAT IS FLUSH WITH THE TOP OF FILTER AND HAVE A 6-INCH THREADED EXTENSION PIPE. THE FURTHEST CLEANOUT FROM THE OUTLET MUST HAVE THE MINIMUM REQUIRED FILTER MEDIA DEPTH. TOP OF RISER ELEV. - 91300 ET CONCRETE RISER STRUCTURE WITH 6" THICK 3,500 PSI PRE -CAST CONCRETE RISER WALL 1 +50 DO NOT COMPACT BOTTOM SCARIFY BOTTOM PRIOR TO UNDERDRAIN INSTALLATION . .00m. ■■■■■ 1■■■■■■■ M■■■■■1■_ ■� ■T�:!■ s-� -� .--- - ----. . TOP VIEW 0 O 2+00 SAND FILTERS SF-1 PROFILE VIEW 5.2 �� 3.0 3'X3' REINFORCED CONCRETE RISER (INTERIOR DIMENSIONS) SINGLE E ELEVATION @ CENTER OF ORIFICE = I 50-YR, 24-HP WATER SURFACE ELEVATION = 91339 ET 820 310 DATUM ELEV 800 2+50 24" REINFORCED CONCRETE PIPE (TO FES-2) INLET INVERT ELEV. = 808.50 FT OUTLET INVERT ELEV. = 808.22 FT LENGTH = 40.00 FT SLOPE = 0.70% BAR MAT 0 12" ON CENTER ;H DIRECTION =TE PIPE THE RISER 3E 0-RING PIPE HARD PIPE TO UNDERDRAIN COLLECTION SYSTEM 5' X 5' X 1.0' 3,500 PSI CONCRETE SPREAD FOOTING WITH (2) REBAR MATS CONSISTING OF #5 REBAR 12" ON CENTER IN EACH DIRECTION RISER STRUCTURE DETAIL 5.2 SCALE: N.T.S. Firm License # P-1191 7140 Weddington Road Suite 140 Concord, NC 28027 Civil Site Design Low Impact Development Small Scale Building Design Telephone: 704.573.1621 Facsimile: 704.248.7951 Seals: ll Mvv N CAR �° 2'/ by " Q SEAL r _z> 032006 0-_ GINC gS°R°QP\ ��11111111� 01-14- 2019 Project Number: 17-18-092 Date:, e, 0 1/ 1 4/20 1 9 Drawn ,By: , EMIL Checked By: NRP l Revisions: 07-2G-18 ORIGINAL SUBMITTAL 0 10-23-18 PER DEVELOPER 1 2- I G-1 8 FEK TOWN OF GRANITE QUARRY A O 1 -1 4-1 9 FEK TOWN OF GRANITE QUARRY Sheet Title: SAND FILTER SF-1 PLAN AND DETAILS Sheet No: 601