Loading...
HomeMy WebLinkAboutNC0086924_Inspection_20200116ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director David L Clegg Tyrrell County 108 S Water St Columbia, NC 27925-0449 NORTH CAROLINA Environmental Quality January 16, 2020 SUBJECT: Compliance Inspection Report Reverse Osmosis WTP NPDES WW Permit No. NCO086924 Tyrrell County Dear Mr. Clegg: The North Carolina Division of Water Resources conducted an inspection of the Reverse Osmosis WTP on 1/15/2020. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0086924. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact me with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481 or via email at robert.e.bullock@ncdenr.gov. Sincerely, 4�bbie Bullock, Environmental Specialist II Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: Laserfiche North Caro teDepartrnartotErvrorrrert* Qus4ly I DvsorofWaterFesocrces Mash, rgtor, Reg ora Woe I 943%Vash rgmr, Scow* Nei I West, rgtom, North -Cato ro 27999 + 1 •••••, 2524W-8481 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO086924 111 12 20/01 /1 s 17 18 LCJ 19 LG j 201 1 21111111111111111111111111111111111111111111 r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ----------------Reserved------------- 67 70 LJ 71 J72 LnJ 73IL_L74 751 I I I I I 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:45AM 20/01/15 19/11/01 Reverse Osmosis WTP Albemarle Church Rd Exit Time/Date Permit Expiration Date Columbia NC 27925 12:30PM 20/01/15 22/10/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted David L Clegg,108 S Water St Columbia NC 279250449//252-796-1371/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit N Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program 0 Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s 1 pector(s) Agency/Office/Phone and Fax Numbers Date Robert E Bullock �/�(! ,( DWR/Division of Water Quality/252-948-3924/ Paul M Mays DWR/WARO WQ/252-948-3940/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type (Cont.) 31 NCO086924 I11 121 20/01/15 117 18 ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The review period for this inspection was 8-15 through 11-19 There were 4 Notice of Deficiencies, 6 Notice of Violations and 2 Enforcements for copper over the review period. On 11-1-2019 a Permit was issued with a compliance schedule for copper. The facility must meet the permitted copper limits by 10-31-2022. April 2019 DMR was spot checked for accuracy. Flouride was reported in ug/I on DMR with the result reported in mg/I. The April 2019 DMR needs to be revised. The facility was found to be compliant with Permit NC0086924. Page# Permit: NCO086924 Owner - Facility: Reverse Osmosis WTP Inspection Date: 01/15/2020 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ M ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? M ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? M ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? ❑ 0 ❑ ❑ Is the chain -of -custody complete? M ❑ ❑ ❑ Dates, times and location of sampling ❑ Name of individual performing the sampling ❑ Results of analysis and calibration ❑ Dates of analysis ❑ Name of person performing analyses ❑ Transported COCs ❑ Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ 0 ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ M ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ M ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ 0 ❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ ❑ M ❑ Is a copy of the current NPDES permit available on site? ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: April 2019 DMR was spot checked for accuracy. Flouride was reported in uq/I on DMR with the result reported in mg/I. The April 2019 DMR needs to be revised. Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ M ❑ application? Is the facility as described in the permit? M ❑ ❑ ❑ # Are there any special conditions for the permit? M ❑ ❑ ❑ Is access to the plant site restricted to the general public? M ❑ ❑ ❑ Page# 3 Permit: NCO086924 Inspection Date: 01/15/2020 Permit Is the inspector granted access to all areas for inspection? Owner - Facility: Reverse Osmosis WTP Inspection Type: Compliance Evaluation Comment: The current permit is set to expire on 10-31-2022. Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE ■ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Comment: The facility is feild parameter certified (PH, DO and SC) with all other samples sent to Environment 1 for analysis. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? M ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ Comment: IntruLogic Corperation calibrated the flo meter on 3-5-2019 Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? M ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? 0 ❑ ❑ ❑ Comment: No adverse conditions were noted from the shore on the day of inspection. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? ❑ ❑ 0 ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees M ❑ ❑ ❑ Celsius)? Page# 4 Permit: NC0086924 Inspection Date: 01/15/2020 Effluent Sampling Owner - Facility: Reverse Osmosis WTP Inspection Type: Compliance Evaluation Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Upstream / Downstream Sampling Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? Comment: Yes No NA NE ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ Page# 5