Loading...
HomeMy WebLinkAboutNC0025691_Wasteload Allocation_19941118NPDE!G DOCUWEMT SCANNINO COVER SHEET NPDES Permit: NC0025691 Littleton WWTP Document Type: Permit Issuance Wasteload Allocation r Authorization to Construct (AtC) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Correspondence Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: November 18, 1994 Thies doCume Lt ira printed on reuse paper - ignore any content on the reverse side NPDES WASTE L C AD ALLOCATION 1 PERMIT NO.: NCO025691 PERMITTEE NAME: Town of Littleton FACILITY NAME: Littleton W WTP Facility Status: Existing Permit Status: Renewal Major Pipe No.: 001 Minor -V Design Capacity: 0.280 MGD Domestic (% of Flow): Industrial (% of Flow): 1 11 '� Comments: 71z1 RECEIVING STREAM:ButterwoodC�k Class: C-NSW Sub -Basin: 03-03-04 Reference USGS Quad: B 27 NW (please attach) County. Halifax Regional Office: Raleigh Regional Office Previous Exp. Date: 2128/95 Treatment Plant Class: II Classification changes within three miles: No change within 3 miles Requested by: 5EA4 GneCS Prepared by: Reviewed by: �D Date: 6ltoll Date: Date: Il' Modeler Date Rec. # .J u7 Drainage Area (mil ) Avg. Streamflow (cfs): 7QI0 (cfs) Winter 7Q10 (cfs) 30Q2 (cfs) Toxicity Limits: IWC % Acute/Chronic htstream Monitoring: Parameters Upstream Location Downstream Location Effluent Characteristics Summer Winter BOD5 (mg/1) NH3-N (mg/1) D.O. (mg/1) TSS (mg/1) F. Col. (/100 ml) pH (SU) i� Comments: �'Y 14- � At�,U/,o Fecc, �-= 20Q �J2D •n/ -:EWC -- ---0 T---- --50 - -, A) coo254 g ( 611146� -- ..��.LIFwt , r.� SOC PRIORITY PROJECT.• Yes �No If Yes, SOC CW'g0wG 29 ' To: Permits and Engineering Unit Water Quality Section Attention: Sean Goris Date: August 23, 1994 NPDES STAFF REPORT AND RECOMMENDATION County:Halifax NPDES Permit No.: NCO025691 (Renewal) PART I - GENERAL INFORMATION 2 1. Facility and Address: Town of Littleton Wastewater Treatment Plant P.O. Box 87 Littleton, NC 27850 2. Date of Investigation: August 12, 1994 3. Report Prepared by: Peggy Redmond 4. Persons Contacted and Telephone Number: Mr. Nathaniel Kimble, operator in,responsible charge (919) 586-3456 5. Directions to Site:'From Raleigh, take U.S. 401 N to Hwy. 561 N at Louisburg'. Take Hwy 4 N to Littleton; facility is approximately 0.5 miles outside of town limits. 6. Discharge Point(s), List,for all discharge points: Latitude: 36024'54"N Longitude: 77054'22"W Attach a USGS map extract and indicate treatment facility site and discharge•point on map. U.S.G.S. Quad No.: B 27 NW U.S.G.S. Quad Name: Littleton NC, 7. Site size and expansion area consistent with application_? XX Yes No If No, explain: 8. Topography (relationship to flood plain included): Facility location relatively flat with very little slope (less than 5%). SOC PRIORITY PROJECT: If Yes, SOC No. Yes No X 1 9. Location of nearest dwelling: Dairy farm approximately 500 feet. 10. Receiving stream or affected surface waters: Butterwood Creek -Index number 28-79-25-7-1 a. Classification: C NSW b. River Basin and Subbasin No.: 03 03 04 C. Describe receiving stream features and pertinent downstream uses: Drains to Bear Swamp, then Little Fishing Creek and ultimately to the Tar River PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of Wastewater to be permitted: .280 MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the Waste Water Treatment facility? .280 MGD C. Actual treatment capacity of the.current facility (current design capacity)? .280 MGD d. Please provide a description of existing or substantially constructed wastewater treatment facilities: Bar screen, grit chamber pumps, oxidation ditch, sludge pump station, pH adjustment (chemical), final clarifier, chlorination, effluent flow meter, and post aeration. 2. Residuals handling and utilization/disposal scheme: Aerobic digester and six sand drying beds (two currently empty). Ultimate disposal in county landfill. 3. Treatment plant classification (attach completed rating sheet): Class II 4. SIC Code(s):4952 Wastewater Code(s) of actual wastewater, not particular facilities i.e..; non -contact cooling water discharge from a metal'plating company would be 14, not 56. Primary 01 Secondary' Main Treatment Unit Code: 1 0 2 - 1 SOC PRIORITY PROJECT: Yes No If Yes, SOC No. PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipal only)? No 2. Special monitoring or limitations -nci requests: Butterwood Creek is a fe o/low-flow 7Q10 stream 3. Other Special Items: The dairy farm has significant impact on the upstream monitoring when they land apply their dairy waste. 4. Alternative Analysis Evaluation: Has the facility evaluated all of the non -.discharge -options available? Please provide regional perspective for each option evaluated. Spray Irrigation: N/A Connection to Regional Sewer System: N/A Subsurface: N/A Other disposal options:, N/A 5. Other Special Items: Residuals disposal in landfill is not under the provisions on 40 CFR Part 503. PART IV - EVALUATION AND RECOMMENDATIONS Based upon this site visit, the facility was well maintained and operated. No monitoring violations were identified. The RRO recommends renewal of the NPDES permit no. NC002.5691. Sign ite of report preparer. . fl �7 .WcFter Quality Regional Supervisor Date LITTLETON.REP