Loading...
HomeMy WebLinkAboutWQ0041335_Application (FTSE)_20191202DWR Didslon of ltesaee+tts State of North Carorm Department of Environmenta Quality Division of Witter Resources 1SA NCAC AZT AM — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number- IA kO t f 13 (w becemoeted try DWRt Al[ Items mast be completed or the ianliestlon of be releaed 1. APPLICANT INFORMATION: (jw 1. Applicant's name: t:duecombe Coumv (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: Michael Matthews per l 5A NC Ac W I .y j, l Title: Direr or 4. Applicant's mailing address: PO Box 10 City: Tarboro State: NC Zip: 27886-� S. Applicant's contact information: Phone number, G5_2) 823-7397 Email Addrcss michaelmatthc%;,-(a edeecomba o.com 11. PROJECT INFORMATION: ❑ Privately -Owned Public Utility x,j us ❑ Other / V/v "> (e f,., 1. Project name: Utility Construction Plans — SR-320054 2. ApplicationlProject status: ❑ Proposed (New Permit) ® Existing PermitlProjcet tf a modification, provide the existing permit munber: WQ00j5G and issued date: 215f2018 If new construction but part of a master plan, provide the existing permit number_ WQt10 3. County where proj= is located: Edgecombe 4, Approximate Coordinates (Decimal Degrees): Latitude: 35.9730011 Longitude:-77.7__ 15485' 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) 111. CONSULTANT INFORMATION: 1. Professional Engineer Michael V Zaccardo.PE License Number. WQ21 Firm: Wetherill Engineering. Inc. Mailing address: 1223 ]ones Franklin Road City: Ralerg State: NC Zip: 27606 Phone numlxr (29) 851-Mn Email Address: mracraMoi6we1h=iIkmg,.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Edemmbe County Wastewater Treatment Plant Permit Number. NC 0030317 Owner Name: Edeecombe County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Sin, ff MI 1010 inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): RA A U Z FORM: FtA 04-16 Page 1 of 3 VI. GENERAL RE.QUtREMENTS 1. if the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ®No ❑N/A 2. if the Applicant is a Developer of lots to be sold, has a Dcveloper's Oocraponal Agreement ( FORM? DEV) been attached? ❑ Yes []No ®N/A 3. !f the Applicant is a Hance ,re nrrs A.wciation, hm Ag C)vcrauunul Ag(SMnt FORM• HOAI been attached? ❑ Yes ❑No ®NIA 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparadon/senic e ❑ Hotel and/or Motels ® School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ® Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) S. Nature: of wastewater: 100 0/9 Domestic/Commercial % Commercial % Industrial (See 15A NCAC 021- .01Q(2n)) %Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 027 ,O k l 4((1? ❑ Yes ® No i• If Yes. provide a EMof flow reduc . ' appmvAlletter 7. Summarize wastewater generated by project: Establishment Type (see 21P.0114(()) Daily Design Flog a> No. of Units Flow gav GPD gall GPD gal! GPD gay GPD gay GPD gal/ GPD Total GPD a See 15A NCAC 02*1 .0114(b), (d). (c,H i I and (0Q for caveats to wastewater design flow rates (Le, minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of time Atlantic Intracoastal Waterway to be used as vacation rentals as defaud in G.S. 42A-4). b Per 1 SA NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A.-NCAC021.0 t 141 shall be determined using available flow data, water using fixtures, occupancy or operation pattern;, and other measured data. g. Wastewater generated by project GPD (per 15A NCAC 021 0114) > Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number ® Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of V11. 1. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - Summarize gravity sewer to be permitted: & C Grawk y Section II & 1U of the MDC for Permitting of Gravity Sewers contains information related to design criteria Y Section III contains information related to minim1un slopes for gravity sewer(s) Y Oversizieg lines to meet tainlasum,hope requirement Is not allowed and a violation of the MDC VIU. PUMP STATION DESIGN CRITERIA (IfApplieabk)-02'1-0303 & MDC eampStatloaslFor hiahLs): CQAIPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitudm Lnu itude. - 3. Design flow of the pump station- millions gallons per day (firm capacity) 4. Operational points) of the prmop(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): size (iacben) Length (feet) Material 12" 613 R9 DIPS HDP>E, Rd DIP 6. Power reliability in accordance with 15(% NCAC Q23 .03U51hH I is ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(hx I)(B)_ P Required for all pomp stations with an average daily flow greater than or equal to 15,000 gallons per day Y Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day. ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(hx l)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - ISA NCAC 02T .0305(hH l)(C): 1- It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. Y If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 M SETBACKS & SEPARATIONS —(02B .0200 & ISA NCAC 02T .0305(I))-. 1. Does the project comply with all separations found in 15A NL(�.i' 02 UZUS & i ISA NCAC 02T.030511) cnntainc minimimt .rnrtrtteinnc that ehull i r nm%AAnA 1'nr ❑ Yes ®No Setback Parameter'' Separation Rc uire d Stoma sewers and other utilities not listed below Ivertie:al) 24 inches Water trains (vertical -water over sewer including in benched trenches) 18 inches Water mains Ihorzzontal) 10 feet R=Wmed water lines t vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - re claimcd over sewer) 2 feet "Any private or public water supply source, including any wells, W S-1 waters of Class I or Class H impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (accept WS-1 or wS-v), B, SA, ORW, HQW, or SB from normal hiA water for tide elevation and wetlands (see item Dt-2) 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement nt 10 feet Top slo • of embankment or carts of 2 feet or more vertical het ht 10 feet Drainage system s and interceptur drains 5 fat Anv swimming pools 10 feet Final earth ruck (vertical) 36 inches b 15A NCAC 02T,0305tr') contains alternatives where separations in 021.0305(fl cannot be achieved. Y **Stream classifications can be identified using the Division's NC Surface Water Cla". 43ication% web -nag If noncompliance with 021' 03 S r ILL see Section X of this application 2. Does the pmject comply with separation requirements for wetlands? (50 feel of separation) ® Yes ❑ No Y Seethe Division's draft separation requirements for situations where separation cannot be meet i No variance is required if the alternative design criteria specified is utilized in design and construction Y As built documents should reference the: location of areas effected 3. Does the preje ct comply with all setbacks found in the river basin rules per I $A NCAC 0213 .U200? ®Yes ❑ No Y This would include Trout Buffered Streams per 15A.NCAC 21020' 4. Does the project comply with an individual 404 Permit or any 401 Certifications! ® Yes [:]No Y Wetland -related permits shall be requested obtained, and adhered to for projects that impact we lands or surface waters Y Information can be obtained from the 4(1 I & buffer P ittmg grtticfi 5_ Does project comply with ISA N AC 02.1.010 c 6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority" Per I SA NCAC 021.040?, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to mbanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No Y If Yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be Inspected by the permittee or Its representative at least once every six -months and Inspections documented per ISA NCAC 02T.0403(a)(5) or the permiteers individual System -Wide Collection permit. FORM: FfA 04-16 Page 4 of 5 x CERTIFICATIONS: 1. Does the submitted system comply with I i A NC A_ C 021, the Mmim m fug thc Pcnnitung vfeull]ySiatign+ noel lcprct lain;, t la y , and the Gravity wcr Molimutn De ien Cnicrip Hpitm version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternadve Design Request application (VADC 10-14) and supporting documents for review. Approval of the request Is required prior to submittal of the Fast Track ApaUcation and supporthie documents. 2. Professional Engineers Certification: I,--- W 1G1l1-h9i'r W`...-Z-Wt!�67 d_ I attest that this application for l JProfessions Engincer's name from Applica ion Item III.I.) L, r,01 �rz - kezow/,c tuts been reviewed by me and is accurate, complete and consistent with the information gpplied in the plans. spxiftcations, engineering calculations, and all other supporting documentation to the best of my knowledge. I fiuthcr attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Pemritting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials utter my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. MOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. ApplicwWs Certification per 15A NCAC 02T .0106(b): Cfin��j, V. 6 l� I, z,2:ke_ z attest that this application for (Signature Authority's name & title from Application Item I3-) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments arc not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. i will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all requited parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215,6A and 143-215,6B, any person who knowingly makes any false siatement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000 as well as civil penalties up to S25,000 per violation" Signature: Date: _ FORM: FrA 04-16 Page 5 of 5 . #-. WETHERILL ENGINEERING 1223 Jones Franklin Road tax Qttizlicy Raleigh, North Carolina 27606 Tnvironoco (919) 851-8077 Fax (919) 88 -01 Poi www.wetherillenia.com NCDENR tce To: Raleigh Regional Office le1gh�egt���l Of 3800 Barrett Drive Raleigh, NC 27609 ATTN: NCDENR Staff Date: December 2, 2019 Attention: NCDENR Staff Re: Force Main Sewer Relocation Fast Track Application for Force Main Sewer Relocation on Bridge No. 320054 over Tar River on SR 1243 (Leggett Rd NCDOT Project 17BPA.R.101 Edgecombe County, N.C. We are sending to you lJ Enclosed ❑ Email O Under separate Cover O Shop Drawing O Submittal Date ❑ Progress Drawings 21 Prints O Tracings ❑ Specifications ❑ Documents ❑ Other COPIES DATE NUMBER 2 11/26/19 Fast Track Application (FTA 04-16 2 10/25119 Engineers Report — Gravity and Sewer Force Main Relocation 1 11115 19 Check #23794 for $480 payable to NCDEQ for application fee 2 11 /15/19 Color USGS map showing site location and street view 2 11/26/19 Watershed Classification Attachment (form WSCAS- 01-I5 These are transmitted as follows: ❑x For Approval 0 For Your Use 13 As Requested 0 For Review & Comment Dear NCDENR-DWR Staff, 0 Approved as Submitted 0 Approved as Noted 13 Please Return 13 Other Enclosed please find our Fast Track application package for the above referenced project. If you have any questions during your review; do not hesitate to give us a call at 919-851-8077. Thanks Date 12/2/19 Signed: 'fao e , / Scott L. Kennedy 14 NC Dept of Environmental Quality Raleigh 11�L %IM36NOB 7ranspoddon PlerreN 8*19WStrudwal WE Oeslgn Your Torn now CIVMee Raleigh Regional Office C°� °"°" Swmft October 24, 2019 Engineers Report Sewer Force Main Relocation Bridge No. 3200S4 over Tar River On SR 1243 (Leggett Rd) NCDOT Project # 17BP.4.R.101 Bridge No.54 Edgecombe County, NC Sewer System Owner /Applicant: Edgecombe County PO Box 10 Tarboro, NC 27866 252-623-7387 Michael Matthews Project Description The purpose of this 613' t/- sanitary sewer force main relocation is due to the fact that NCDOT will be replacing the existing bridge across Tar River and the existing sewage forcemain will be In conflict with the new bridge construction. The location of this work is along SR 1243 (Leggett Rd.) between SR 1250 (Old Rocky Mount Battleboro Rd) and SR 1252 (Dunbar Rd). The improvements include the construction of approximately 184 LF of 12" RJ DIP and 429 LF of IT DR 9 (IPS) HDPE force main which will be placed via directional drill method beneath Tar River. This work will be performed in accordance with the NCDOT BMP for Construction and Maintenance Activities dated August 2003. The new relocated 1Y RJ DIP and 12" DR 9 (DIPS) HDPE sanitary sewage force main will be owned, operated, and maintained by Edgecombe County, N.C. Water and Sewer Department. All construction will be In accordance with the latest standards and specifications of the NCDOT, North Carolina Department of Transportation and the NCDEQ, Division of Water Resources, Water Quality Permitting, PERCS Unit. 2223 Jones Franklln Road Raleigh, NC 27606 Phone: (919) 951-8077 Fax: (919) 951-8107 1209 Floral Parkway Wilmington, NC 29403 DWR �� • LG e State of North Carolina tz�t������ artment of Environment and Natural Resources Division of Water Resources Division of Water Resources Watershed Classification Attachment (WSCAS 01-15) Along with this form, submit a color copy of a USGS Topographic Map to identify the project area and waterbodies. Each map or maps must show the location of the sewer system and include location identifiers where the system traverses over or near waterbodies. The map should have location In's for each different waterbody and corresponding classifications should be recorded. Include the completed form and map portions with the permit application for submittal to the appropriate review agency. A list of the Division's regional offices, their county coverage, and contact information can be obtained from: http://Portal.ncdenr.org/web/wd/home/ro Location ID Name of Waterbody' River Basin Waterbody Index No. Waterbody Classification A Tar River Tar- Pamlico 28-(69) C;NSW 1 It unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary joins. 1 certify that as a Registered Professional Engineer in the State of North Carolina that l have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date r L _�� • w 21 Y " � b • •o r GINS ••q�r.v�° P V4 :r�,ZAGQti�� I Flafii;flsVVSt Deck, Erin M From: Michael Matthews <michaelmatthews@edgecombeco.com> Sent: Monday, January 13, 2020 3:52 PM To: 'Mike Zaccardo' Cc: 'Scott L. Kennedy'; 'Greg Purvis'; Deck, Erin M Subject: [External] RE: Utility Construction Plans-BR-320054 Fast Track Sewer Extension • rnal a ii. l]o not 611W6 if arnpen atta ch merft unless you verify. Sendd-aU:suspiaiou's email as an attad ei tto WQCS00356 is Edgecombe County's Permit # NCO030317 is Rocky Mount's Permit ## Erin, I'm fine with you updating the permit on our behalf. Thanks, Michael C. Matthews Utilities Director- Edgecombe Count3- (252) 823-7387 o / (252) 641-6285 f "Never tape down a fence until ,.ou hnow whi- it eras put up"- Robert Frost From: Mike Zaccardo <MZaccardo@wetherilleng.com> Sent: Monday, January 13, 2020 3:42 PM To: Michael Matthews <michaelmatthews@edgecombeco.com> Cc: Scott L. Kennedy <skennedy@wetherilleng.com>; Greg Purvis <GPurvis@wetherilleng.com>; Deck, Erin M <erin.deck@ncdenr.gov> Subject: RE: Utility Construction Plans-BR-320054 Fast Track Sewer Extension Michael, Scott and I just spoke to Erin Deck about her three comments. The third comment is on us, we checked the wrong box by accident. The Answer to IV: Facility Name -Tar River Regional WWTP, Permit Number NC: Nc 0030317 is correct Owner Name: City of Rocky Mount Erin will make these changes to the application with my and your email confirmation. We need the following info for Section V. Permit for the collection System - WQ�_?? - this would be an Edgecombe permit # and System Wide collection System permit #: WQCS: - this will be a Rocky Mount #. Is it WQCS 00356? Michael - If you can get us this information or possibly just touch base with Erin and clear up these last 2 Section IV items, we will be all set. Erin —you have my permission to revise the application due to these few permit Ws changes. Also, please check YES to the box in Section IX regarding "does the project comply with all separations found in 15A NCAC 02T.0305 (f) and (g) Thank you for your time Mike Zaccardo From: Deck, Erin M <erin.deck ncdenr. ova Sent: Monday, January 13, 2020 1:54 PM To: michaelmatthews ed ecombeco.com; mzaccardo0wetherillene.com Subject: Utility Construction Plans-BR-320054 Fast Track Sewer Extension Good afternoon, We are in the process of reviewing the subject application and require additional information. Section IV. The permit number does not match the facility name. Please clarify where the waste will be treated. Section V. was not filled out. A collection system permit number needs to be provided. Section XI 1. "No" is checked for the project complying with separations found in 15A NCAC 021.035(f) & (g). Please explain. Once this information has been received with can move forward with our review. Thank you. Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office. 919-791-4258 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. State of North C;zroliaa Mpuftent of Environmental Quality W'R Division of Water Resources Dkishm of Wader Re so-wc 15A NCAC 02T MN - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUNIMA13ON Application Number: tm bewm0cted by 0WRF AD Item most be eom leted or the application will be rett reed I. APPLICANT INFORMATION: 1. Applicant's name: Ednecombe County (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3.Signature authority's name: Michael Matthews per l�& `lot.} : ,tti{w6tb1 Tile: Dirrctor 4. Applicant's mailing address: PO Box 10 City: Tarboro State: NC Zip: 27— 886-� 5. Applicant's contact information: Phone number 2(iS2J 823-7387 Email Address: michaeltnatthcu _kMaiedLecomheco_com + 11. PROJECT INFORMATION: 0, l . Project name: Utility Construction Plans — BR-320054 w c 2. Application/Project status: ❑ Proposed Mew Permit) ® Existing Permit/Prrojeu if a modification, provide the existing permit number: WQ00I�L6 and issued date: ZU/2018 o O If new construction but part of a master plan, provide the existing permit number. WQ00 ,r 3. County where project is located: FAQ w 0 4. Approximate Coordinates (Decimal Degrees); Latitude: 35.973001' Longitude: -77.7. 1 S4$5° op 5. Parcel ID (if applicable): A ly (or Parcel ID to closest downstream sewer) U z 111. CONSULTANT INFORMATION: 1. Professional Engineer. Michael V Zaccardo.PE License Number. 022321 Firm: Wetherill Enstineemg. Inc. Mailing address: 1223 Jones Franklin Road City Raleigh State: NC Zip: 27§gk-_ Phone number. WD 81-M Email Address: mzaccardoi&wetherilleng.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: EdeecombS County Wastewater Treatment Plant Permit Number. NC 0030317 Owner Name: Edeecombe Count V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WV*"M- 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: (FM) 10 inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): FORM: I`I'A 04-16 Page I of 5 VI. GENERAL REQUIREMLENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [--]Yes ®No QN/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Oprrahonal Ayrcrntent (FORM, DEV) been attached? ❑ Yes [3No ®NIA 3. If the Applicant is a Home Promi-ty Owners A,,tiocia0on.] aM Owauunttl Aur ment (FORM HOA t been attached? ❑ Yes []No ®N/A 4. Origin of wastewater. (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel andlor Motels ® School / preschool I day cars ❑ Medical l dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Clttirch ❑ Swimming Pool/Filter Backwash ® Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 •A Domestic/Commemial % Commercial % Industrial (See 15A NCAC 021' .0103(201) -Is there a PrcMtment Program in effecC? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 021 .0114(f)? ❑ Yes ® No 'i+ Ifprovide it pMof flow reduction approvA letter 7. Summarize wastewater generated by project: Establishment Type (see 2YI'.0I 14f 1)) Daily Design Flow No. of UnIb Flow gay GPD gay GPD gay GPD gay GPD Say GPD gay GPD Total GPD a See 15A NCAC 02'1 .01141b). (d). (c)(I 1 and {cltw) for caveats to wastewater design flow rates (it, minimum flow per dwelling; proposed unlmown non-rmidential development uses; public access facilities located near high public use areas; and residential property located south or cast of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in (;.S, 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not idmtificd [in table 1 �611CP('02 LV 1141 shall be determined using available flow data. water using fixtures, occupancy or operation pattertrs, and other measured data 8. Wastewater generated by project GPD (per 15A NCAC W 1 0114) ): Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number. ® Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 3 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable)- 027' .03U5 & MDC(Grnyy% 1SrMcrsl; 1. Summarize gravity sewer to be permitted: Size (inches) I LuMM (feet) I Material y Section U & M of the MIX for Permitting of Gravity Sewers contains infornation related to design criteria Y Section ill contains information related to minimum slopes for gravity sewe(s) Y OversDfag limes to meet minimum mope requh=ent Is not allowed and a violation of the MM VHL PUMP STATION DESIGN CRITERIA (1f Applicabk) — 02T .0305 & MN Pu m Statiuus/For Mainsj: COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: ° Longitude: 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic bead (TDH) 5. Summarize the fa= main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 12" 613 R9 DIPS HDPI= .PJ DIP 6. Power reliability in accordance with l5jkNCAC 42`I 03951hM 1 r ❑ Standby power soarcc or pump with automatic activation and tclrsrrctry - 15A NCAC 02T .0305(hx I XH)_ Y Required for all pomp stations with an average daily How greater than or equal to 15,000 gallons per day Y Must be permanent to facility Or if the pump station has an average daily How less than 15,000 gallons per day. ❑ Portable power source with manual activation, quick -connection receptacle and telemetry -15A NCAC 02T _0305(h)( I)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): I- it shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. 1- If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-1 b Page 3 of 5 IX SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC OZT ,0305(f)): t_ Does the project comply with all separations found in 15A N( %C 021, .0305(f) & iel ❑ Yes ® No Y 15A NCAC 02T.0305(1) contains minimum separations that shall he nmvided few Rawer woprnc- Setback Parameter* Separation Etc uired Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer includin K in benched trenches) 1$ inches Water mains (horizontal) 10 feet Reclaimed water lines 1 vertical - reclaimed over sewer) I a inches Reclaimed waterlines (horizontal - reclaimed oversewed 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS-1 or WS-V), B. SA. ORW, HQW, or SB from normal high water or tide elevation and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Anv building foundation 5 feet Any basement 10 feet Top slo c of embankment or cuts of 2 feet or more vertical height 10 feet Drama a sweets and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade ( vertical) 36 inches )- 15A NCAC 02T,0305(s!1 contains alternatives where separations in 021 Wg5l cannot be achieved **Stream classifications can be identified using the Division's biC Surface WgiCE Classifs ations WCbppge Y if noncompliance with 021'.0305(f) or 11). see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ®Yes ❑ No Y Seethe Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction Y As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NQAC 0)200? ® Yes ❑ No );, This would include Trout Buffered Streams per 12A h!CAC 213.0--102 4. Dogs the project comply with an individual 404 Permit or any 401 Certifications? ®Yes ❑ No Y Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters '- Information can be obtained from the iQl & Buffer PWAiMg BrnAch 5. Does project comply with 15A NCAC 0211.010510(6) (additional permits/certifications)? ® Yes ❑ No Per 15A_NCAC_ 02T Q 105(c)(61, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependcot permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are: deemed "high -priority?" Per 15A NCAC 021.041)2, "high -priority sewer'' means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erasion that undermines or deteriorates the sewer. ❑ Yes ® No Y If yes, include an attachment with details for each line, including type (aerial litre, size, material, and location). Nigh priority lines shall be Inspected by the permittee or Its representative at least once every six-mentlts and im ilmdons documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FI'A 04-16 Page 4 of 5 X. CERTIFICATIONS: t. Does the submitted system comply with I SA NCAC 021, the Mrnccn m .i n C11100 LIE tk 1' n , ' ti % and 1 rce MaIns (1att.q1.vgrsionJ. and the 6 d t w _berjimupi PkstenSntsna tlatcst ymigol as applicable? ® Yes ❑ No If No, complete and submit the VariancdAltemative Design Request application (VADC 10-14) and supporting documents for review. Approval of the rr uest Is re aired prior to submittal of the Fast Track Application and supportine documents. 2. Professional Engineer's Certification: 6 j6,149L �� G QAg� attest that this application for JProfessionqj Engincer's name from Applica ion Item 111.1.) A _ has been reviewed by me and IS accurate, complete and consistent with the information sdpphed in the plans, specifications, enginecring calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (Latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judgesd it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to S25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: t• OF 1 3. Applicant's Certification per 15A NCAC 02T .01065(b)= 1, ��l1el Z ,�l�fS -- — attest that this application for (Signature Authority's name & title from Application Item I3,) has been reviewed by the and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all requited supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any disrlmrge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated I also understand that if all required pans of this application package are not completed and that if all required supposing information and attachments are not included, this application package will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6E, any person who knowingly makes any false stwcmcnt, r W==tation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S10,000 as well as civil penalties up to S25,000 per violation. Signature: _-� _ — Late: //� FORM: FTA 04-16 Page 5 of 5 ��E_N SNEERING 1223 Jones Franklin Road Raleigh, North Carolina 27606 (919)851-8077 Fax (919)851-8107 www.wetherilleng.com NC Dept of Environmental Qua To: NCDENR Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 ATTN: NCDENR Staff galeigh Regional Oiftee Date: December 2, 2019 Attention: NCDENR Staff Re: Force Main Sewer Relocation Fast Track Application for Force Main Sewer Relocation on Bridge No. 320054 over Tar River on SR 1243 (Leggett Rd NCDOT Project 17BPA.R.101 Edgecombe County, N.C. We are sending to you ❑X Enclosed ❑ Email 0 Under separate Cover 0 Shop Drawing 0 Submittal Date 0 Progress Drawings 1] Prints O Tracings ❑ Specifications ❑ Documents ❑ Other COPIES DATE NUMBER 2 11/26/19 Fast Track Application (FTA 04-16 2 10/25/19 Engineers Report ^ Gravity and Sewer Force Main Relocation 1 11/I5/19 Check #23794 for $480 payable to NCDEQ for application fee 2 11/15/19 Color USGS map showing site location and street view 2 11/26/19 Watershed Classification Attachment (form W SCAS- OI-15 These are transmitted as follows: 0 For Approval 0 Approved as Submitted 0 For Your Use 0 Approved as Noted 0 As Requested 0 Please Return 0 For Review & Comment 0 Other Dear NCDENR-DWR Staff, Enclosed please find our Fast Track application package for the above referenced project. If you have any questions during your review; do not hesitate to give us a call at 919-85I -8077. Thanks Date 12/2/19 Signed: Scott L. Kennedy ., fir, Raleigh Transportation �� Planning Bridge/Structural WE Design Your Tomorrow _ .. Civil/Site Consiruction Observation Surveying ram — October 24, 2019 Ennineers Report Sewer Force Main Relocation Bridge No. 320054 over Tar River On SR 1243 (Leggett Rd) NCDOT Project # 17BP.4.R.101 Bridge No.54 Edgecombe County, NC Sewer System Owner /Applicant: Edgecombe County PO Box 10 Tarboro, NC 27866 252-823-7387 Michael Matthews Project Description C The purpose of this 613' +/- sanitary sewer force main relocation is due to the fact that NCDOT will be replacing the existing bridge across Tar River and the existing sewage forcemain will be in conflict with the new bridge construction. The location of this work is along SR 1243 (Leggett Rd.) between SR 1250 (Old Rocky Mount Battleboro Rd) and SR 1252 (Dunbar Rd). The improvements include the construction of approximately 184 LF of 12" RJ DIP and 429 LF of 12" DR 9 (IPS) HDPE force main which will be placed via directional drill method beneath Tar River. This work will be performed in accordance with the NCDOT BMP for Construction and Maintenance Activities dated August 2003. The new relocated 12" RJ DIP and 12" DR 9 (DIPS) HDPE sanitary sewage force main will be owned, operated, and maintained by Edgecombe County, N.C. Water and Sewer Department. All construction will be in accordance with the latest standards and specifications of the NCDOT, North Carolina Department of Transportation and the NCDEQ, Division of Water Resources, Water Quality Permitting, PERCS Unit. 1223 Jones Franklin Road Phone: (929) 851-8077 1209 Floral Parkway Raleigh, NC 27606 Fax: (919( 851-8207 Wilmington, NC 28403 C Ir�pmm ll o ssC$C= PP N • 1 pz 1 w.r W111 2 1 y � LLOL 8 MN r oZ r- 0 D_ LU _h f- p UU LU 00 ad ❑ 0. W DWR State of North Carolina Department of Environment and Natural Resources Division of Water Resources Division of Water Resources Watershed Classification Attachment (WSCAS 01-15) Along with this form, submit a color copy of a USGS Topographic Map to identify the project area and waterbodies. Each map or maps must show the location of the sewer system and include location identifiers where the system traverses over or near waterbodies. The map should have location ID's for each different waterbody and corresponding classifications should be recorded. Include the completed form and map portions with the permit application for submittal to the appropriate review agency. A list of the Division's regional offices, their county coverage, and contact information can be obtained from: httr)://Dortal.ncdenr.ore/web/wa/home/ro Location ID Name of Waterbody' River Basin Waterbody Index No. Waterbody Classification A Tar River Tar. Pamltcp 28-(69) C-.NSW I If unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary joins l certify that as a Registered Professional Engineer in the State of North Carolina that l have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PS Seal, Signature and Date