HomeMy WebLinkAboutNC0026824_correspondence_20090922 ALTID-1;WA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Dee Freeman Beverly Eaves Perdue Coleen H.Sullins Secretary Governor Director September 22, 2009 Thomas H. Mercer City Manager City of Creedmoor P.O. Box 765 Creedmoor,NC 27522 Subject: City of Creedmoor Flow Reduction Request Granville County Dear Mr. Mercer: On June 8, 2009, the Pretreatment, Emergency Response and Collection Systems(PERCS) Unit received a flow reduction request for future connections to the City of Creedmoor's sewage collection system. A letter was sent July 7,2009 approving a reduction to 88 gpd/bedroom. The Raleigh Regional Office and the receiving POTW, SGWASA,have expressed concerns regarding the flow data. Based on those comments, additional information is being requested and the flow reduction will not be effective until the additional information can be evaluated. 1. There appears to be some discrepancy in the flow data provided by the City and flow data provided by SGWASA. Please communicate with SGWASA and jointly provide an account of the monthly flow from the Joe Peed Road pump station for December 2007 through February 2009. 2. A letter from Creedmoor states that the flow meter at Joe Peed Road pump station was installed in the year 2002,but no adjustments have been made since. This implies that the flow meter has not been calibrated recently. This comment does not satisfy the requirements of 15A NCAC 02T.0114(f) (1)(A) which requires "Dates of flow meter calibrations during the time frame evaluated and indication if any adjustments were necessary." 3. Please identify the breakdown of connections as per 15A NCAC 02T .0114 (c). 1617 Mail Service Center,Raleigh,North Carolina 27699-1617 One Location:512 N.Salisbury St.Raleigh,North Carolina 27604 NorthCal'ollna Phone:919$07-63001 FAX:919$07-s4921 Customer Service:l$77-623$746 ��turall� Internet www.ncwaterquality.org An Equal Opportunity 1 A(finnadve Action Employer 4. Please provide more detail of your I/I study: discuss how much of they system has been smoke tested,the results, what has been done to reduce I&I, number of SSOs, and a schedule of I&I repairs. I apologize for the inconvenience and the delay in providing these comments. If you have any questions or comments regarding this matter,please contact me at (919) 807-6383,email [Deborah.Gore@nc denr.gov]. Sincerely, Deborah Gore PERCS Unit Supervisor cc: Barry Herzberg,Raleigh Regional Office(via email) Dan Boone, Wooten Company, 120 North Boylan Avenue, Raleigh,NC 27603 (via email) NPDES Unit,Permit File NCO26824 PERCS Flow Reduction File SWP Central File NCO026824 1617 Mail Service Center,Ralegh,North Carolina 27699-1617 One Location:512 N.Salisbury St,Raleigh,North Carolina 27604 NorthCarolina Phone:919-807w300 1 FAX:919-807 64921 Customer Service:t 877 623 6748 ? alt� Internet www.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer