Loading...
HomeMy WebLinkAboutNC0086690_Compliance Evaluation Inspection_20191231ROY COOPER Governor MICHAEL S. REGAN Ss rewry LINDA CULPEPPER Uirerror Shannon Becker, President Aqua North Carolina, Inc. 202 Mackenan Ct. Cary, NC 27511 Dear Mr. Becker: NORTH CARD! INA Envirunmen[al Quality December 31, 2019 Subject: Compliance Evaluation Inspection Stansted Subdivision Well # 2 WTP NPDES Pen -nit No. NCO086690 Hollybrook WTP NPDES Permit No. NCO082996 Wake County ` fV-1 I M1�41.1111i The subject inspections were conducted December 30, 2019 by Mitch Hayes of the Raleigh Regional Office. The cooperation and assistance of Chris Weaver, certified PC -I Operator in Responsible Charge, was greatly appreciated. Below are findings developed from permit review and the inspection: Stansted Subdivision Well #2 WTP I. The current permit was rene%%-ed and became effective November I, 2018 and will expire April 30, 2023. 2. The 0.065 MGD potable water plant consists of the following units: groundwater source well; chlorine disinfection and dechlorination units; two (2) -settling tanks; Bennefloc before and after filters; three (3) greensand filters with backwash flow meter; distribution flow meter; wastewater backwash drain line to settling tank; sand -bed filter with discharge to outfall. 3. All units were in operation at the time of inspection. Effluent appeared clear and free of solids flowing from the discharge pipe. 4. Chris Weaver is field certified for pH and residual chlorine. Eneo Laboratories performs all other permit parameters. 5. COC`s for October 2019 were on file. A check of lab bench sheets to data on the Discharge Monitoring Report (DMR) revealed no transcription errors. North Carolina Department of Env ronmental Quality Division of Water Resources Raleigh Regional Office 3800 Barrett Drive 1628 Lfad Service Center Raleigh. North Carol na 27699-1628 ,, . ,, .y� 6. A review of DMR data from April 2016 to November 2019 include the following: monitoring violation for total nitrogen for 06.2016 and 12.2016; late DMR reporting for 01.201 S. There were no other violations for the review period. Hollybrook Subdivision WTP 7. The current permit was renewed and became effective November 1, 2018 and will expire April 30, 2023. S. The 0.017 MGD WTP consists of the following units: groundwater well at 26 gpm; sodium hypochlorite .' sodium hydroxide feed system; two (2) greensand filters; chlorination dechlorination units; potable water storage tank; wastewater storage; filter backwash to subsurface sandbed; sludge removal for landfill disposal; discharge line to outfall. 9. The WTP has been inactive since 10.08.2015. Well #3 has been capped off. There is no discharge to the environment. Please inform this office if Aqua would like to keep or rescind this permit. I would like,to thank Chris Weaver for his time and assistance with this inspection. If you have any questions about this letter or the inspection, please contact Mitch Hayes at 919.791.4261 or at mitch.haves cuncdenr.l'ov . cc: permit files, Laserfiche Sincerely, 2 J4* Scott Vinson, Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources NC DEQ N";, North Carolina Department of Environmental Quabt} Division of Water Resources 512 North Salisbury Street :1617 Mail Service Center Raleigh. North Carolina 27699.1617 01 a 7n7 0f1r1() Unled States Environmental Protection Agency Form Approved. EPA Washington D C 2W1B0 OMB No, 2040-0957 Water Compliance Inspection Report Approval expires8-31-98 Section A: National Data System Coding (i,e., PCS) Transaction Code NPDES yrlmolday Inspection Type Inspector Fac Type 1 u 2 15 1 3 NC0086690 11 12 19112130 17 18 C; I I 19 I LS J I 20I r — ' r�l 21 6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 CIA Reserved 67 70 (, LJ f, 71 Lj 72 ti) 73 ( ) I74 75 80 LJ I I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10 45AM 19/12/30 18/11101 Stansted Well 92 (WiP) Exit Time/Date Permit Expiration Date Stansted Dr Cary NC 27518 11 30AM 19112/30 23/04/30 Name(s) of Onsite Representative(s)1Tides(syPhone and Fax Number(s) Other Facility Data !!1 Christopher Lee Weaver!!! Christopher Lee WeaverlORCI! Name, Address of Responsible OffciallritlelPhone and Fax Number Joseph R Pearce 202 Mackenan Crt Cary NC 27511lOireclor of Contacted Operationsl919-653-6964/9194601788 No Section C Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 RecordslReports Self -Monitor ng Program 0 Facility Site Review Effluent/Receiving Waters Section D Summary of FindinglComments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signalure(s) of Inspector(s) AgencylOffice/Phone and Fax Numbers Date Mitchell S Hayes DWRlRRO WC:919-791.42D0! Signature of Management C A Reviewer Agency;Office:Phone and Fax Numbers Date /R40 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete Pagr.: HPDES yrtmolday Inspection Type (Cont.) 31 NCO086690 I11 12 19112130 17 18 ICI Section 0 Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The current permit was renewed and became effective November 1, 2018 and will expire April 30, 2023. The 0.065 MGD potable water plant consists of the following units: groundwater source well; chlorine disinfection and dechlorination units; two (2) -settling tanks; Bennefloc before and after filters; three (3) greensand filters with backwash flow meter; distribution flow meter; wastewater backwash drain line to settling tank; sand -bed filter with discharge to outfall. All units were in operation at the time of inspection. Effluent appeared clear and free of solids flowing from the discharge pipe. Chris Weaver is field certified for pH and residual chlorine. Enco Laboratories performs all other permit parameters. COC's for October 2019 were on file. A check of lab bench sheets to data on the Discharge Monitoring Report (DMR) revealed no transcription errors. A review of DMR data from April 2016 to November 2019 include the following, monitoring violation for total nitrogen for 06.2016 and 12.2016; late DMR reporting for 01.201 B. There were no other violations for the review period. Permit: NCO086690 Owner • Facility: Stansted Well #2 (1+WiP) Inspection Data: I V30l2019 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ M ❑ application? Is the facility as described in the permit? ❑ 0 ❑ ❑ # Are there any special conditions for the permit? ❑0 ❑ ❑ Is access to the plant site restricted to the general public? ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Two settling tanks have been added to aid in Manganese and Iron removal with the addition of benefloc. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 Cl ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 0 ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete- do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 2417 with a certified operator ❑ ❑ M ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? M ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? M ❑ ❑ ❑ Facility has copy of previous years Annual Report on file for review? ❑ ❑ ❑ Comment: October 2019 data was reviewed. There were no errors. Effluent Pipe Yes No NA NE Is right of way to the outfall property maintained? 0 ❑ [l ❑ oagc# 2 Permit: NCODS669D Inspection Date: 12/3012019 Owner -Facility: Stansted Well #2 (WTP) Inspection Type: Compliance Evaluation Effluent Pipe Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Effluent appeared clear with no foam or solids. Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: Samples are GRAB type. Flow is based on estimate. Yes No NA NE M ❑ ❑ ❑ ❑ ❑ M ❑ Yes No NA NE ❑ ❑ M ❑ ■ ❑ ❑ ❑ M ❑ ❑ ❑ ❑ ❑ M ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Pages 4 United States Environmental Protection Agency Form Approved. EPA Washington D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr moeday Inspection Type Inspector Fac Type 1 u 2 15 1 3 I NC0082996 111 121 1902:30 I17 18 I C I 19 I fi LJ LJ I 201 I LI 21 6 Inspection Work Days Facility Self-Momtonng Evaluat on Rating B1 QA Reserved 67 70 71 f 1 72 I ., I 73I I J174 751— _ _ II 1 I ' 4 I8O I I I I I I r Section B Facility Data Name and Location of Facility Inspected:For Industrial Users discharging to POTW also include Entry TimelDate 3-ermit EHe=tine Date POTW name and NPDES Permit Number) 10 OOAM 19-12130 1sit 1101 Hollybrook WTP Exit Time:Date Permit Expiration Date OH Kildare Farm Rd Cary NC 27519 10 30AM 19-12 30 2Y04130 Name(s) of Onsite Representative(silTitlests)iPhone and Fax N„mber(s) Cther Facility Data ur Christopher Lee Weaverl:' Christopher Lee WeaverlORC;- Name Address of Responsible OfficiaUTitWPhone and Fax N;,mber Reid Andrew Campbe11,202 Mackenan Cl Cary NC 27511:�'919-476-8712r .L Ia. ted No Section C Areas Evaluated During Inspection (Check only those areas evaluated) Permit Facility Site Review Section D Summary of Finding/Comments (Attach addil.onal sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspeclor(s) Agency:Off ce.-Phone a--d = ax N.-mbers Date Mitchell S Hayes (- �L DWRIRRO WQ;919-791.42007 �� �G�i�,J r7 i TI �i I � • ? � • �G` � Signature of Manage rpen1 O A Reviewer Agency:Off ce:Phone and Fax Numbers Date / EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. pagWr NPOES yr-ma,day Inspection Type 31 NCoo82996 111 121 19/12130 117 18 I I Section D. Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) WTP Plant ceased operation 10.08.201.5, There was no discharge. Subdivision is connected to the Town of Cary public water supply. Permit can be rescinded if Aqua agrees to. Page# Permit: NCOOB2996 Inspection Date: 12/30/2019 Owner • Facility: Hollybrook WTP Inspection Type: Compliance Evaluation Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Yes No NA NE ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ M ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Comment: Plant ceased operation 10.08.2015. There was no discharge. Subdivision is connected to the Town of Cary Public water supply. Permit can be rescinded if Aqua agrees to.