Loading...
HomeMy WebLinkAboutSW6190802_2020-01-05 Supplement Form_1/5/2020SUPPLEMENT-EZ COVER PAGE FORMS LOADED .PROJECT INFORMATION 1 Project Name Four Sierra Ranch 10 2 Project Area ac Coastal Wetland Area ac 3 0 4 Surface Water Area ac 0 5 Is this project High or Low Density? High 6 Does this project use an off -site SCM? No COMPLIANCE WITH 02H .1003[4j 7 Width of vegetated setbacks provided feet 8 Will the vegetated setback remain vegetated? Yes 9 Is BUA other that as listed in .1 0034 c-d out of the setback? Yes 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System Bioretention Cell 1 12 0 0 0 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-F5 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Da Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Ba filter 0 26 1 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Jeffrey A, Nobles, PE Larry King & Associates, RLS, PA 28 JOrganization. 29 Street address: 1333 Morganton Road Suite 201 30 City, tateZip: Fayetteville, NC 28305 31 Phone numbe s : _ Email: 910-483-4300 32 _ jnobles@lkanda.com Certification Statement: I certify, under penalty of law that this Supplement-FZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. A""A11ti►III, ., "CAP � r _ SEAL - 314.59 - 4Fyrb- tA- Sign r- ),Ipj - - 9 -S-l9 Date DRAINAGE AREAS 1 Jjs this a high den ity project? Yes 2 If so, number of drainage areas/SCMs 1 Is all/part of this project subject to previous rule 3 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM Infil Basin 266341 sf 27885 sf 5 Total BUA in ro ect ft 71776 sf 6 New BUA on subdivided lots (subje7topermitting) s ft 58500 sf 13276 sf 7 New BUA outside of subdivided lots (subject to rmitting) (so 11391 sf 8 Offsite - total area Lsq ft sf sf 9 Offsite BUA (sq ft sf sf 10 Breakdown of new BUA outside subdivided lots: Parking (sq ft sf sf Sidewalk (sq ft sf sf Roofs ft sf sf Roadway (sq ft 13276 sf 11391 sf Future (sq ft sf sf Other, please specify in the comment box below ft sf sf 11 New infiltrating permeable pavement on subdivided lots ft sf sf 12 New infiltrating permeable pavement outside of subdivided lots s ft Exisitng BUA that will remain (not subject to s ft Existing BUA that is already permitted tt sf sf 13permitting) sf sf 14 sf sf sf 15 Existing BUA that will be removed (sq ft sf 16 Percent BUA 16% 16% 17 Desi n storm inches 1 in 1 in 18 1 Design volume of SCM cu ft 6493 cf 6493 cf 19 1 Calculation method for design volume Simple Method Simple Method DDITIIONAL INFORMATION Please use this space to provide any additional information about the 20 draina a area(s): INFILTRATION SYSTEM 1 Drainage area number 2I Design volume of SCM (cu ft) UKRAL MQC FROM 021-1.1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? 4 Is the SCM located away from contaminated soils? 5 What are the side slopes of the SCM (H:V)? 6 Does the SCM have retaining walls, gabion walls or other engineere 7 Are the inlets, outlets, and receiving stream protected from erosion 1 8 Is there an overflow or bypass for inflow volume in excess of the de: 9 What is the method for dewatering the SCM for maintenance? 10 If applicable, will the SCM be cleaned out after construction? 11 Does the maintenance access comply with General MDC (8)? 12 Does the drainage easement comply with General MDC (9)? If the SCM is on a single family lot, does (will?) the plat comply with 13 (10)? 14 Is there an O&M Agreement that complies with General MDC (11)? 15 Is there an O&M Plan that complies with General MDC (12)? 16 Does the SCM follow the device specific MDC? 17 Was the SCM designed by an NC licensed professional? NFILTRATION SYSTEM Mnt FRf3M 02H .7r1S7 side volume? General MDC 1 Yes Yes 3:1 No Yes No Pump (preferred) Yes Yes Yes Yes Yes Yes 18 Proposed sfope of the subgrade surface (%) 0% 19 Are terraces or baffles provided? No 20 Type of pretreatment: Forebay I Sails Data 21 Was the soil investigated in the footprint and at the elevation of the infiltration system? Yes 22 SHWT elevation (fmsl) Avg 155.07 23 Depth to SHWT per soils report (in) >120 24 Ground elevation at boring in soils report (fmsl) 165.20 25 Is a detailed hydrogeologic study attached if the separation is between 1 and 2 feet? 26 Soil infiltration rate (inlhr) 0.24 27 IFactor of safety (FS) (2 is recommended): 2.00 crerveruwis 29 Bottom elevation (fmsl) 159 ft 30 IStorage elevation (fmsl) 165. ft 31 jBypass elevation (fmsl) For Basins Oral 32 Bottom surface area, ff : 12747 ft 33 jStorage elevation surface area (ft2) 13000. ft For Trenches Only 34 Length (ft) 35 Width (ft) 36 Perforated pipe diameter, if applicable (inches) 37 Number of laterals 38 Total length of perforated piping 39 Stone type, if applicable 40 Stone void ratio (%) 41 Is stone free of fines? 42 Is the stone wrapped in geotextile fabric? 43 Has at least one infiltration port been provided? Volumes/Drawdown 44 Design volume of SCM (cu ft) 6493 cf _ 45 Time to drawdown (hours) 47 hrs X750FTIONAL INFORMATION Please use this space to provide any additional information about the infiltration 46 system(s): Infiltration 1 6755 PM 11517n2n