Loading...
HomeMy WebLinkAboutSW3191202_3 - Northgate Supplemental Form_1/2/2020SUPPLEMENT-EZ COVER PAGE FORMS LOADED :OJECT INFORMATI N 1 Project Name 2 Project Area ac 3 Coastal Wetland Area The Residence at No 7.53 4 1 Surface Water Area ac 0 5 Is this project High or Low Density? High 6 Does this project use an off -site SCM? No COMPL E WITH 02H .1003(4) 7 Width of vegetated setbacks provided (feet) 25' front and rear setbacks; 5' side setback 8 Will the vegetated setback remain vegetated? Yes 9 Is BUA other that as listed in .1003 4 c-d out of the setback? Yes 10 Is streambank stabilization proposed on this project? No BER AND TYPE 11 Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 1 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 1 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Ba filter 0 26 Filterra 0 FORMS LOADED SIGNER CERTIFICATION 27 Name and Title: Brian Smith, PE 28 Or anization: Urban Design Partners 29 Street address: 1318-e6 Central Avenue 30 City, State, Zip: Charlotte, NC 28205 31 Phone numbers : 704-334-3303 32 1 Email: brian@urbandesignpartners.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision, that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete, and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. ``,I I I I I I I I II �N CARO , O -ESS16 •. %i QQ;o tiy�. 9 SEAL 027890 � ••'FNG I NE�P.��Z` '��I111 Illll��` Si Designer 12.13.2019 Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 1 3 Is all/part of this project subject to previous rule versions? No FORMS LOADED A INFORMATION Entire Site 1 M N/A Sand Filter in ro ect s ft 103966 sf 92114 sf on subdivided lots (subject to permitting) 7permitting) N/A N/A outside of subdivided lots (subject to s 103966 sf 92114 sf 8 Offsite -total area (sq ft 12931 sf 12931 sf 9 Offsite BU(sq ft 1790 sf 1790 sf 10 Breakdown of new BUA outside subdivided lots: Parkin (sq ft 48669 sf 48669 sf Sidewalk (sq ft 23024 sf 9381 sf Roof (sq ft 32274 sf 32274 sf Roadway s ft N/A N/A Future (sq ft N/A N/A Other, please specify in the comment box below (sq ft N/A N/A 11 New infiltrating permeable pavement on subdivided lots (sq ft N/A N/A 12 New infiltrating permeable pavement outside of Isubdivided lots (sq ft N/A N/A 13permitting) Exisitng BUA that will remain (not subject to s ft N/A N/A 14 Existing BUA that is already permitted (sq ft N/A N/A 15 Existing BUA that will be removed (sq ft 8706 sf 8706 sf 16 Percent BUA 32% 43% 17 Design storm inches 1 in 1 in 18 Design volume of SCM cu ft 5852 cf 5852 cf 19 1 Calculation method for design volume TSS TSS ADDITIONAL INFORMATION 20 Please use this space to provide any additional information about the drainage area(s): N/A DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM N/A Sand Filter 5 Total BUA from project (sq ft) 6 1995 rules SL 2006-246 2008 rules 2017 rules 103966 sf 92114 sf 7 New BUA on subdivided lots (subject to permitting) (sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules N/A N/A 8 New BUA outside of subdivided lots (subject to permitting) (sf) 1995 rules SL 2006-246 2008 rules 2017 rules 103966 sf 92114 sf 9 Offsite - total area (sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules 12931 sf 12931 sf 10 JOffsite BUA (sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules 1790 sf 1790 sf 11 Design storm (inches) 1995 rules SL 2006-246 2008 rules 2017 rules 1 in 1 in 12 Breakdown of new BUA: Parking (sq ft 48669 sf 48669 sf Sidewalk (sq ft) 23024 sf 9381 sf Roof (sq ft 32274 sf 32274 sf Roadway (sq ft) N/A N/A Future (sq ft N/A N/A Other, please specify in the comment box below (sq ft N/A N/A 13 New infiltrating permeable pavement on Isubdivided lots (sq ft N/A N/A 14 New infiltrating permeable pavement outside of subdivided lots (sq ft N/A N/A 15 Exisitng BUA that will remain (not subject to permitting) (sq ft) N/A N/A 16 Existing BUA that is already permitted (sq ft N/A N/A 17 Existing BUA that will be removed (sq ft 8706 sf 8706 sf 18 Percent BUA 32% 43% 19 Design volume of SCM (cu ft) 5852 cf 5852 cf 20 Calculation method for design volume TSS TSS ADDITIONAL INFORMATION 21 Please use this space to provide any additional information about the drainage area(s): N/A SAND FILTER 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion (10- Iyear storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice 10 If applicable, will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC (8)? Yes 12 1 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes ISAND FILTER MDC FROM 02H .1056 18 SHWT elevation (fmsl) 19 Type of sand filter (open or closed) Open 20 If closed, will the filter will be pre -cast or pour -in -place? 21 If closed, top of grate elevation (fmsl) 22 Is this sand filter designed to attenuate peak flows? Yes I Sediment Chamber 23 Volume that can be retained in the sediment chamber (cubic feet) 9225 cf No 24 Will there be a permanent pool in the sediment chamber? 25 Bottom of the sediment chamber (fmsl) 906.00 26 Area of the sediment chamber (square feet) 4040 sf 27 Physical depth of the sediment chamber (inches) 48 in 28 Ponding depth in the sediment chamber, above any permanent pool (inches) 24 in 29 Elevation of top of weir between chambers (fmsl) 908 Sand Chamber 30 Volume that can be retained in the sand chamber (cubic feet) 9210 cf 31 Bottom of the sand chamber (fmsl) 905.00 32 Area of the sand chamber (square feet) 3585 sf 33 Physical depth of the sand chamber (inches) 48 in 34 Ponding depth in the sand chamber, above any permanent pool (inches) 24 in 35 Elevation of the bypass device (fmsl) 36 Type of bypass device 37 Mechanism for distributing flow over the sand surface 38 Sand specification for sand chamber cleaned washed "concrete" sand bed 39 Depth above underdrain pipe (inches) Will the media be maintained to drain at least two inches per hour at the sand surface? 18 in 40 Yes 41 Is at least one clean -out pipe provided at the low point of each underdrain line? Yes 42 Will clean -out pipes be capped? Yes INFORMATION Please use this space to provide any additional information about the 43 Sand Filter(s): N/A Sand Filter 4 11:56 AM 11/26/2019