Loading...
HomeMy WebLinkAboutSW3190803_C32_12/31/2019SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Salem Leasing Corporation 2 Project Area ac 10.725 3 Coastal Wetland Area ac 4 Surface Water Area ac 5 s thisho"pacteith i wo Hi h aLon CM?us6DosH er ffD-seintes No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks rovitlad feet 8 WII the ve etated setback remain ve elated? 9 Is BUA other that as listed in .1003 4 c-d out of the setback? 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCIM: 11 Infiltration System 0 12 Bioreterltion Cell 0 13 Wet Pond 1 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 1 Level S reader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface CIS 0 21 Treatment Swale 0 22 D Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Ba filter 0 2,;FiOerra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Matthew Grant CEO 28 Or anization: Jordan Grant 8 Associates, PLLC 29 Stree[addmas: 2351 Simonton Rd 30 City, State, Zip: Statesville NC 28625 31 Phone numbers : 704-928-7919 32 Email: mattg@jordanyrsnt.com Certification Statement: I certify, under penalty of lawthatthis Su lament-EZ form and all supporting information were prepared under direction or dY. Pe N PP PPo 9 P eP m9 n; that the information provided in the form is to the beat of knowledge and belief, true accurate, and complete and supervision; P � my 9 � � � P that the en ineerin plans, specifications, operation and maintenance agreements and other supporting information are consistent 9 n P Pe Pe 9 PP 9 w;tn me information provided Here. \k CAlpp�'�, O .oE�sS/''•.�'%y� SEAL 33292 _ FW I. GRQ,��. rrhnrnu111d1 Signature of Designer Dacember3O,2019 Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 1 Is all/part of this project subject to previous rule 3 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM Wet pond 1 5 Total BUA in project (sq ft 362057 sf 314751 sf 6permitting) New BUA on subdivided lots (subject to s ft 7 New BUA outside of subdivided lots (subject to ermittin s 8 Offsite - total area (sq ft 9 Offsite BUA (sq ft 10 Breakdown of new BUA outside subdivided lots: Parking (sq ft 354,349 sf 307,033 sf Sidewalk (sq ft 718 sf 718 sf Roof (sq ft 7000 sf 7000 sf Roadway s ft Future (sq ft Other, please specify in the comment box below (sq ft 11 New infiltrating permeable pavement on 1subdivided lots (sq ft 12 New infiltrating permeable pavement outside of subdivided lots (sq ft 13permitting) Exisitng BUA that will remain (not subject to s ft 14 Existino BUA that is already permitted (sq ft 15 Existing BUA that will be removed (sq ft 16 Percent BUA 79% 79% 17 Design storm inches 1 in 1 in 18 IDesign volume of SCM cu ft 28561 cf 28561 cf 19 ICalculation method for design volume Simple Simple ADDITIONAL INFORMATION 20 Please use this space to provide any additional information about the drainage area(s): No. 5 - 47,306 sq. ft. of BUA is outside wet pond drainage area. WET POND 1 Drainage area number 1 2 Design volume of SCM (cu ft) 28561 cf GENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? aFes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion (10-year storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Pump (preferred) 10 If applicable, will the SCM be cleaned out after Construction? Yes 11 Does the maintenance access comply with General MDC (8)? Yes 12 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is an a single family lot, does (will?) the plat comply with General MDC (10)? 14 Is there an O&M Agreement that complieswith General MDC (11)? Yes 15 Is there an O&M Plan that complies with General MDC (12)? No 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? WET POND MDC FROM 02H .1053 18 Method used Yes SAIDA 19 Has a stagelstorage table been provided in the calculations? Yes 20 Elevation of the excavated main pool depth (bottom of sediment removal) (fmsl) 895.00 21 Elevation of the main pool bottom -(top of sediment removal) (fmsl) 896.00 22 Elevation of the bottom ofthe vegetated shelf (fmsl) 899.00 23 Elevation of the permanent pool (fmsl) 899.50 24 Elevation of the top ofthe vegetated shelf (fmsl) 900.00 25 Elevation of the Ypool tem orar p ( frn sl ) 900.50 26 Surface area ofthe main permanent pool (square feet 9494 27 Volume of the main permanent pool (cubic feet) 24804 cf 28 Average depth ofthe main pool (feet) 3.00 ft 29 Average depth equation used Equation 2 30 If using equation 3, main pool perimeter (feet) 31 If using equation 3, width of submerged veg. shelf (feet) 32 Volume of the forebay (cubic feet) 3757 cf 33 Is this 15-20% ofthe volume in the main pool? Yes 34 Clean -out depth for forebay (inches) 12 in 35 Design volume of SCM (cu ft) 9764 cf 36 Is the outlet an orifice or a weir? Orifice 37 If orifice, orifice diameter (inches) 1.25 in 38 If weir, weir height (inches) 39 If weir, weir length (inches) 40 Drawd own time for the temporary pool (days) 2.77 41 Are the inlet(s) and outlet located in a manner that avoids short- circuiting? Yes 42 Are berms or baffles provided to improve the flow path? No 43 Depth offorebay at entrance (inches) 36 in 44 Depth offorebay at exit (inches) 24 in 45 Does water flow out ofthe forebay in a non -erosive manner? Yes 46 Width ofthe vegetated shelf (feet) 6 ft 47 Slope of vegetated shelf (H:V) 6.1 48 Does the orifice drawdown from below the top surface of the permanent pool? Yes 49 Does the pond minimize impacts to the receiving channel from the 1- yr, 24-hr storm? Yes 50 Are fountains proposed? (If Y, please provide documentation that MDC(9) is met.) No 51 Is a trash rack or other device provided to protect the outlet system? Yes 52 Are the dam and embankment planted in non -clumping turf grass? Yes 53 Species of turfthat will be used on the dam and embankment (Festuca rubra) 54 Has a planting plan been provided for the vegetated shelf? Yes ADDITIONAL INFORMATION 10 55 Please use this space to provide any additional information about the wet pond(s): �rr���7���7�w•�1T��7�����r���hwww`������t�T�T�L��I J:5U I I UI"I LL-L V H I iUIN: 89510 / / / / 36" HDPE INV.881.70 I RISER CREST 901.75 1.25' PVC STUBBED OUT INT❑ TEMPORARY POOL 900.50 1.25' PVC SCREW TYPE PLUG 1.25' PVC TEE NORMAL POOL 899.50 DEWATERING METHOD: IICP PI IMP Tfl TIPAW nn\./KI 41 SCALE: 1"=30' 4 CB _4" HDPE Z re VEGETATED SHELF - HATCHED + + + � � -I- APPROXIMATELY 9,030 SQUARE FEET AT ELEV. 900.0 2258 PLANTS REQUIRED - 50 PER 200 SF ® 24-36" OC IN RANDOM, MERGING GROUPS 1025 PLANTS SHOWN PLANT MATERIAL LIST QTY JOE—PYEPVL4bT NAME SIZE / NOTE LOCATION ON SHELF 300 CHELONE GLABRA 4" POT PLACE AT LOWER ELEVATION WHITE TIRTLEHEAD GROUPS OF 20 300 HIBISCUS COCCINEUS DP50 PLUG PLACE AT LOWER ELEVATION SCARLET ROSE MALLOW GROUPS OF 10-20 800 ASCLEPIAS INCARNATA DP50 PLUG SCATTER THROUGHOUT SWAMP MILKWEED GROUPS OF 15-25 800 CAREX TENERA 2.5" CAL. B&B PLACE AT UPPER ELEVATION QUILL SEDGE RANDOM 58 EUPATORIADELPHUS FISTOLOSUS 1 GALLON CONTAINER SCATTER THROUGHOUT AS SHOWN MULCH ENTIRE VEGETATED SHELF WITH 2-3" SHREDDED HARDWOOD BARK PLANT DAM AND EMBANKMENTS WITH NON -CLUMPING Creeping Red Fescue (Festuca rubra) 7' JTLET STRUCTURE DETAIL N.T.S. ✓ERT: 882,00 TRASH RACK WEIR 4X4 PRECAST CONCRETE STRUCTURE 0, 36'x3' ❑PENING ON ALL 4 SIDES 30' RCP OUTLET PIPE 4 CY OF CONCRETE ANTI -SWEEP MEASURE \ �(\ / ZO •oF ES S/p''., �9 SEAL _ 33292 _ NGIN6:%� �/lllllllt 11-25-19 z J00 z z cv T__1 Q `^ Q^1 W � 00 • Q LLI ZJ U J 0 ti O U) LLJ (n Lu E a- 00� � 06 Q o It U) Cn IiY • Q * C LL 11Y U-) r>3 LLJ <z O O LLJ m R 0 Q 0 LLJ O 4 � } 0 LU LU U In N O � IN O N � OZ z a —I o 0 O W r-I O N O Z Z a a' O Ul w LU Q N U � Ln z �, O L a J J }m II Oz J LL Iol � O O� LU LU Jwwg LU Q o < o 0 0 Z � a w °C w LULU � L.L 00 0 J N p U N N LU J J J V) LU Q tii to LU In r) LU LU Q Y w z U) Z< M O < w mr-71� 0 z O LU O o 0 13 � ID � 13 CAD (D CAD m OI H—I ON 1 o ON 1 1 CD OC) , o p \ LU in U) U) g U oC a a UU a UU UU U Ln LU U) U) (71 (71 00 w 1 In 1 N M 1 Q +—I o +--I M N 'I Z Sheet No: C32