HomeMy WebLinkAbout20190593 Ver 3_I-5111-I-4739 401 Buffer Mod Wake_Johnston December 10 2019_20191223-A�a STAniEmH
STATE OF NORTH CAROLINA
DEPARTMENT OF TRANSPORTATION
Roy COOPER
GOVERNOR
December 10, 2019
N.C. Division of Water Resources
1617 Mail Service Center
Raleigh, NC 27699-1617
Attn: Rob Ridings
NCDOT Project Coordinator
JAMES H. TROGDON, III
SECRETARY
Subject: Modification Request for Section 401 Water Quality Certification and Neuse Riparian
Buffer Authorization for Interstate 40 Widening and Improvements from I-440/US 64 (Exit
301) to just north of SR 1525 (Cornwallis Road), including improvements to NC 42 and SR
1010 (Cleveland Road) in Wake and Johnston Counties, Federal Aid Project No. IMNHF-040-
4(139)301; TIPS I-5111 and I-4739, Division 5; Debit $570 from WBS Element 42346.3.1.
Dear Mr. Ridings,
The North Carolina Department of Transportation (NCDOT), applied for permits for the subject project
on May 7, 2019. The North Carolina Division of Water Resources issued 401 Water Quality Certification
for the project on July 10, 2019 (NCDWR Project No. 20190593).
It has come to our attention that several proposed riparian buffer impact areas needed revisions. These
areas were visited in the field by staff from NCDOT, RK&K, and S.T. Wooten on December 2, 2019.
This matter has already been brought to your attention by NCDOT Division 5 staff.
Attached are revised buffer drawings depicting the affected areas. These revisions reflect additional
impacts to mitigable Buffer Zone 1 areas following Division 5 staff field reviewing of the top of banks
and edge of transportation facility areas at each location. The following sheets have been modified:
• Buffer drawing 1 of 52: titlesheet
• Buffer drawing 23 of 52: plansheet 31 reflecting revisions to Sites 23A and 23B
• Buffer drawing 24 of 52: plansheet 32 reflecting a revision to Sites 26A
• Buffer drawing 47 of 52: summary table
• Buffer drawing 51 of 52: summary table
The following impacts were revised:
Site 23A: previous mitigable zone 1 impact total: 8,260 sqft; new mitigable zone 1 impact total:
10,192 sqft (difference of 1932 sqft)
Site 23B: previous mitigable zone 1 impact total: 635 sqft; new mitigable zone 1 impact total:
1,037 sqft (difference of 402 sqft)
MAILING ADDRESS:
NC DEPARTMENT OF TRANSPORTATION TELEPHONE: 919-707-6000 LOCATION:
ENVIRONMENTAL ANALYSIS UNIT FAX: 919-212-5785 CENTURY CENTER, BUILDING A
1598 MAIL SERVICE CENTER 1000 BIRCH RIDGE DRIVE
RALEIGH NC 27699-1598 WEBSITE: NCDOT.GOV RALEIGH NC, 27610-4328
• Site 26A: previous mitigable zone 1 impact total: 233 sqft; new mitigable zone 1 impact total:
422 sqft (difference of 189 sqft)
• Overall total project previous mitigable zone 1 impact total: 299,329 sqft; new mitigable zone 1
impact total: 301,854 sqft (difference of 2,525 sqft)
Please note that due to rounding of the impacts at these sites as well as the others, the overall increase
difference for these sites is 2,523 sqft, however the table shows 2,525 sqft.
These new drawings have revision dates of 12/4/2019.
Compensatory Mitigation
NCDOT has requested the appropriate additional mitigation from the N.C. Division of Mitigation
Services. The revised acceptance letter will be provided once it is received by the Department.
REGULATORY APPROVALS
Section 401: We are requesting modification of the Section 401 Individual Water Quality Certification
and Neuse Riparian Buffer Authorization from NCDWR. We are providing this modification request to
NCDWR, for their approval. Authorization to debit the $570.00 Permit Modification Fee from WBS
42346.3.1 is hereby given.
A copy of this request and its distribution list will be posted at
https://xfer. services.ncdot. @pdea/PermApps/.
If you have any questions or need additional information, please contact Gordon Cashin at
gcashin@ncdot.gov or 919-707-6107.
Sincerely,
DocuSigned by:
Mack C. pav"k 111
", 248B309416...
for Philip S. Harris, III, P.E., C.P.M.
Environment Analysis Unit Head
2
qu
h
U
O
C
1T
L
to
t
3
7
T
U
V
3
0
L
0
0
(D
E
C
0
C
w
V)
a_
i
0
See Sheet 9-B For Flan Sheet Symbols
40
RALEIGH a4o 64
cPbr e KNIGHTDALE
C ek `° 90
WENDELL
4401
Lake Nlalnut
Johnson GreeK
y 64 26 3
�
1
64
40 440 64
x
` u�
F
`5'`Yhce k
BEGIN
PROJECT
Lake GARNER'
Wheeler
Z
4O7
Lake
BUS N
•
Benson
C
�� m
CLAYTON
42
2
42
4 er 0 '0 50
LO
70 70
I
ake
���
END
JohnstoCunt
*° PROJECT
Airport
VICINITY MAP (NTS)
SITE 2
SITE 3�
SITE I�
STATE OF NORTH CAROLINA
DIVISION OF HIGHWAYS
WAKE & JOHNSTON COUNTIES
LOCATION: I-40 FROM I-440 /US 64 (EXIT 301) TO JUST NORTH OF SR 1525
(CORNWALLIS ROAD), INCLUDING IMPROVEMENTS TO NC 42 AND
SR 1010 (CLEVELAND ROAD).
TYPE OF WORK: GRADING, DRAINAGE, PAVING, WIDENING,
RESURFACING & STRUCTURES
B UFFER IMPACTS
NOTES:
1. A PORTION OF THIS PROJECT IS WITHIN THE MUNICIPAL BOUNDARIES OF THE CITIES OF RALEIGH & GARNER.
2. CLEARING ON THIS PROJECT SHALL BE PERFORMED TO THE LIMITS ESTABLISHED BY METHOD III MODIFIED.
3. THIS IS A CONTROLLED —ACCESS PROJECT WITH ACCESS BEING LIMITED TO INTERCHANGES.
GRAPHIC SCALES DESIGN DATA
ADT 2018 = 106,200
50 25 0 50 100 ADT 2040 = 137,200
DHV = 65%
PLANS D — 9%
50 25 0 50 100 T — 9%
V = 70 MPH &
PROFILE (HORIZONTAL) FUNC CLASS: 75 MPH **
URBAN INTERSTATE
l0 5 0 10 20 * (TTST 5% + DUAL 4%)
** DESIGN SPEED CHANGES
PROFILE (VERTICAL) N, AT US 70 BUS
c0
PROJECT LENGTH PLANS PREPARED BY:
R—EL, KLEPPER S, 1-1, LLP
900 RID EFIELD DRIVE, SUITE 350
LENGTH ROADWAY TIP PROJECT 1-5111 /1-4739.......................... 12.950 miles RALEIGH, NORTH CAR ve09
NC LICENSE NO. F-0112
LENGTH STRUCTURE TIP PROJECT 1-5111 /1-4739.......................... 0.094 miles FOR NORTH CAROLINA TOTAL LENGTH OF PROJECT 1-5111 /1-4739................................. 13.044 miles DEPARTMENT OF TRANSPORTATION S. T WOOTEN
2018 STANDARD SPECIFICATIONS
NCDOT CONTACT I Brandon J. McInnis, P.E.
PROJECT ENGINEER
3YDRAULICS
ENGINEER
Aw
BUFFER DRAWING
SHEET 1 OF 52
REVISED 8282019
REVISED 12/42019
SITE 21
END TIP PROJECT 1-5111/1-4739
DOCUMENT NOT CONSIDERED FINAL
UNLESS ALL SIGNATURES COMPLETED
®g NOR
04*
P.E.
SIGNATURE.
ROADWAY
DESIGN
a
ENGINEER
O'z TR OP
KZak Hamidi,P.E. LETTING DATE: Mary E. Yahl, P.E.
PROJECT ENGINEER - DESIGN -BUILD UNIT J U N E 19, 2 01 8 PROJECT DESIGN ENGINEER P E
SIGNATURE:
BUFFER DRAWING MITIGABLE IMPACTS ZONE 1
PROJECT REFERENCE NO. SHEET NO.
/-511111-4739 3/
SHEET 23 OF 52
MITIGABLE IMPACTS ZONE 2
NAD 83 SHEET NO.
DES
ROADWAY DESIGN HYDRAULICS
ENGINEER
ENGINEER
G L I
This document originally
This document originally
issued and sealed by
issued and sealed by
Mary E. Yahl, 040878,
Matthew L. Cook, 27434,
on 06-06-2019.
on 06-06-2019.
This medium
This medium
shall not be considered a
shall not be considered a
certified document.
I certified document.
DOCUMENT NOT CONSIDERED FINAL
UNLESS ALL SIGNATURES COMPLETED
VALLIE SAULS, HEIRS
JEFFREY WILSON REVISED
12/472019
23D
23B
FS L I
� SLH
SITE 23B
BZ 2� BZ 2
--�
82 1 BZ 1
H BZ�
2 TONS CL B RIP RAP
SITE 23A O SY GEOTEXTILE
ON BANKS ONLY
LENGTH =S'
(SEE DETAIL BB)
SP. LAT. 4' BASE DITCH
BZ�
BZ 2 BZ 2
O
\ 11 TONS CL BTRIP_RP.P 1B_� —,
BZ 1 _\ Nc Riw Riw MON '� BZ 1
N
M
BZ 1 W/28 SY GEOTEXTILE
BL1 FLARE RIP RAP OUT
exist
P R/W MO ��� ���-n-� \ Milli
M
W
ez 2 IN BUFFER ZO
re
W
LLI
ez 2
al FS,r
C-- S�—cL. Sr--°[_" Sr `S` _ c� ��
��_JSE!�
W
N
--- — e2
.. .. .. .. .. Ts�1B"a
W
W
W
N
Conv. DI TO 1B wMH
P BZ 1 2G WS 2
N
0
----iacoNc -- --- ----------
--- ---- — ------ iacoNc ---
7 BZ 2
O
0
_— — — _
---- ---- REMOVE DI o-------------
zr'nmr^_
- — — — - ----------------
- EOi -- REMOVE DI ------
__—_— -- -.360//TB 2GIA-ST--------------
.3�JJ4CUP—132Y7�— ------ --
O
-- - -
M
24" RCP
e I I . w - - rrT6 2GIB-ST
M
TB 2GI&ST --
— z —
------ -- - ----- — ---_
Z_
Q
-----------------------
-- �, --Conv.DI—
ra'caNc
—_ -
TO JB iocomc
----- --
J
I
18" RCP-
DI
�!
J
W
REMOVE 1S'
�iD_wss "
15" RCP- PROP. BARRIER
W
Z
_
-E180W5 D R
_
---- EIP
Q
2GIB-WSS m
R/W MON
CL B RIP P -
ai MON WAID S EOTEXT LE —'�
` l
v
CONCR E DITCH m
BEHIND ALL DENNIS L. POWELL ONCRETE A C
'3o SEE D!fi -BE v, J SEE DETAIL BE
ro sN
. -
MELISSA RBOSA 6ND WIIFELSUNSHINESDEBIN '. WILLIAM C. MCLAMB SP.
oON
W/CL B RIPRAPTCH
SEE DETAIL AD
G
.s ' ,�J �}
O
s`cs i
5 WAUDDELL J. ROBINSON JR.
N 03'16155.5 ' E 00 N
55.53
29 a>�GJQ MR. & RS. HARRIS D. FALL
MARVA LEIS
32 0 a
O 29B
00 00
K7 0 JN� 6 _Q WD —
a 0O - a "ss.ol•ol
o �
2SFD
ISFD
2SFD h m 2SFD fh
``--ii.•�u
it-ISFD
/0� ISFD�.
f] I Q } 8 0�-I
ISFD
€J
0
CHARLIE L. FOBBS
F N RiC��lC
P: (919)878-9560
900 Ridgefield Drive Suite 350I Raleigh, North Carollna 27609-3960
NC License N0. F-0112
'"-- '— Engineers I Construction
wwrv.rkk.com
Managers I Planners I Scientists
Responsive People Creative Solutions
BUFFER DRAWING MITIGABLE IMPACTS ZONE 1
PROJECT REFERENCE NO. SHEET NO.
1-511111-4739 32
SHEET 24 OF 52
+_NAB
MITIGABLE
IMPACTS ZONE 2
SHEET NO.
DESIGN HYDRAULICS
ROADWAY DES
W
ENGINEER ENGINEER
This document originally This document originally
G I
issued and sealed by issued and sealed by
Mary E. Yahl, 040878, Matthew L. Cook, 27434,
O EIP
on 06-06-2019. on 06-06-2019.
This medium This medium
shall not be considered a shall not be considered a
S 7" W
certified document. certified document.
420 0
420.5'
EIP
--
DOCUMENT NOT CONSIDERED FINAL
UNLESS ALL SIGNATURES COMPLETED
�T
REVISED 12/4/2019
JEFFREY WILSON
_
w
-
U ��
M�pN NCR fl o? -Fs.
plR \2
[SL 11
\
ROY R. SMITH
\
C ^ 13'S5' w �Q y •
SITE 2'Y">'00 �N �C ROY R. SMITH
BZ 2
3 TONS CL B RIP RAP
TILE
W/10 UP EOTE)( TO SITE 2 3 C
BULL SY RIPRAP
PERCHED OUTLET ELEVATIO 29p`
BZ 2
- �,-'9Z 'd
— .. , \�
r �: \ B=?
\'0 87
-
w LINE ENTI 3 TON L B RIPRAP
PENINSU BETWEEN
o o W/10 S GEOTEXTILE
STREAMS FOR ABILIZATION
o 'BUILD RIPRAP TO
v o 10 TONS CL IP RAP
io - - - - - - E - TLET ELEVATION
BZ 1
BZ BZ 2—
BZ 1
.. a i
=
_ _ _ _ .
m W/28 SY GEOT E -.
SEM
r
M
BZ 1 SP. LAT. BASE BZ
W/CL I RIPRAP
>e ve
B= 1 M
'B\f°—
B= I BZ 1 BZ ,
w--r°_r°—r°�rs�
Lu
SEM
-sr
�����— &�
_a
LLI
LU
N
_
° a
----------
—
U-I
1B�re�_ �re
2GIB-W3Fe---
ire re�-re_m_
eV)
NPROP.
SEG
1" _I 2— BZ1
h 2
T �r
IO'CONC ---- ----
BZ 7
—3i ---- Ia CON qV —��T
--
/-40 WBL 23'8ST
E0T
80
O
'
E�
��___ BZ 2
+
r%-�'�� — — — — ---
—
_
— — — — — —
38��80%-- R MLOVE DI 5 RCP -III
M
I\
-- —
-—
__
TB
M
ae
REMOVE DI ---TB 2GIB-ST —L—
S 7I9v 576-W
Q
_
----
_ _ _ EaP _____
-----
__ _____
_ -- ---
TB 2GIB-ST
_ _ __ ______
- - -- 4'-6BN�— ----
1-40 EBL 2YEST
_—_ EOT
------
Ln
EOT
-------------
N
----------------------------------
a covc
----
a coNc
----------
J
2GIB-WSF J
PROP. BARRIER 15" RCPIIIfill 9
B=2
W
tl
�\\`- _ --�—ILLI
z..
�_-------------------�
-- ----- F Z
SITE25 15"CSP ___ ------
2 ELBOWS '6N
01
— re�°`�°��BB='°—ems
re�_ _- J _ '8`re_�_
_—B—re—m—a
_- Jl� �n '^ �'a J
WILLITe
AM C. MCLAMB EIP ,
<a\
Now. �' C/BZ
BZ
SP. LAT. 4' BASE DITCH �,
Exis Riw
BZI
- -
BZ1 \ /
W/CL B RIPRAP ��
SEE DETAIL AD
W
\ \
- m�V `'3�i' io
// 1
Stu IT. 4' BASE DITC
m W/CL B RIPRAP \\\� 1
0 9EE DETAIL AD +++
� ��
aiw Non
BZ 2 B=?
S N K
/
BZ 2
2 TONS CL B RIP RAP
V( W/7 SY GEOTEXTILE
ROY R.
SMITH ON BANKS ONLY
LENGTH=S'
(SEE DETAIL BB)
RIDGEVIEW SUBDIVISION HOMEOWNERS ASSOC.
JS BEGINS �� J
e� e
SITE 26A
5' �1 \
44.54'4'
N 04017150" E
1277. T4'
JS BEGINS
5F �„
00
ti5
RiC��fC
P: (919)878-9560
900 Ridgefield Drive Suite 350 Raleigh, North Carolina 27609-3960
i5" W
NC License N0. P-0112
Engineers I Construction Managers I Planners I Scientists
www.rkk.com
Responsive People I Creative Solution°
RIPARIAN BUFFER IMPACTS SUMMARY
IMPACTS
BUFFER
TYPE ALLOWABLE MITIGABLE REPLACEMENT
Site Station Structure ROAD PARALLEL
No. (From/To) Size / Type BRIDGE ZONE 1 ZONE 2 TOTAL ZONE 1 ZONE 2 TOTAL ZONE 1 ZONE 2
CROSSING IMPACT ( 2) ( 2) ( 2) ( 2) ( 2) ( 2) ( 2) ( 2)
ft ft ft ft ft ft ft ft
14A
-L- 168+89-169+89 LT
BANK STABILIZATION - SRM
X
1658
946
2604
14B
-L- 172+50-172+88 LT
BANK STABILIZATION - SRM
X
1824
1680
3504
14C
-L- 175+81-176+98 LT
BANK STABILIZATION - SRM
X
2795
277
3071
15
-L- 186+18-188+55 LT
ROADWAY FILL - SRJ
X
0
90
90
16A
-Y5RPD- 22+19-22+50 RT
EXIST. 24" CMP PLUG
X
2032
2231
4263
16B
-Y5RPD- 24+79 RT
EXIST. 15" CMP PLUG
X
613
306
918
16C
-Y5RPC- 53+20 LT
60" RCP - SCF, WQF
X
1489
0
1489
17
-Y5RPC- 54+38-55+47 RT,
-L- 250+27 LT,
-Y5RPA- 21 +91-23+05 RT
BANK STABILIZATION - SOE, WQV
X
12126
3903
16028
18
-L- 256+39-257+51 LT & RT
DITCH, 66" WSP- SOI, WSD
X
6922
3626
10548
19
-L- 272+67-275+51 LT & RT
DITCH, 66" WSP - SNF
X
8722
5049
13771
20
-L- 281+93-284+50 LT & RT
CHANNEL CHANGE - SNH, WQE,WRX
X
3953
956
4909
21
-L- 322+40-323+33 LT & RT
CHANNEL CHANGE, 72" RCP, SNY
X
8579
4452
13031
22
-L- 323+52-325+32 RT
CHANNEL CHANGE - SOC
X
3438
1054
4493
23A
-L- 361+15-364+65 LT
CHANNEL CHANGE - SLF / SEM
X
10192
2082
12274
23B
-L- 368+90-369+15 LT
BANK STABILIZATION - SEM
X
1037
0
1037
23C
-L- 374+40-378+99 LT
CHANNEL CHANGE - SEM
X
11509
228
11738
24
-L- 378+63-379+21 LT
BANK STABILIZATION - SLI
X
1108
0
1108
25
-L- 373+59-374+08 RT
ROADWAY FILL/ DITCH - SNM
X
61
775
836
26A
-L- 381+90 RT
BANK STABILIZATION - SNK
X
422
0
422
26B
-L- 385+01-385+81 RT
ROADWAY FILL - SNK
X
1025
0
1025
-L- 385+80-386+06 RT
BANK STABILIZATION - SNK
X
712
0
712
27
-L- 386+06-386+88 RT
BANK STABILIZATION - SNO
X
1765
1079
2844
28
-L- 387+14-387+47 LT
60" WSP - SEM
X.
1116
0
1116
TOTALS*:
31431
15161
46592
51667
13572
65239
0
0
NOTES:
REVISED 12/4/2019
Revised 2018 Feb
RIPARIAN BUFFER IMPACTS SUMMARY
IMPACTS
BUFFER
TYPE ALLOWABLE MITIGABLE REPLACEMENT
Site Station Structure ROAD PARALLEL
No. (From/To) Size / Type BRIDGE ZONE 1 ZONE 2 TOTAL ZONE 1 ZONE 2 TOTAL ZONE 1 ZONE 2
CROSSING IMPACT
(ft2) (ft2) (ft2) (ft2) (ft2) (ft2) (ft2) (ft2)
39
ONLY IN PERMIT SET
40
-L- 99+00-107+44 LT & RT
BRIDGE
X
14449
7030
21479
1104
2993
4097
41
ONLY IN PERMIT SET
42
-L- 106+42-107+44 RT
ROADWAY FILL - SDN, WEN
X
7169
5126
12295
43
-L- 109+63-114+04 RT
ROADWAY FILL - SEO
X
7471
4557
12028
44
-L- 110+99-115+29 LT & RT
60" RCP, DITCH - SEQ, WEO(1)
X
12849
6061
18910
45
-L- 143+25-145+12 LT
48" CSP - SEU
X
11384
6539
17923
46
-L- 164+25-164+78 RT
30" CSP / 36" RCP - SEA, WOE
X
10987
7345
18332
47
-Y1 RPA- 16+15-17+72 RT
54" CSP - SLV
X
5350
2012
7362
48
ONLY IN PERMIT SET
49
-L- 170+95-175+40 LT & RT
66" WSP / 66" RCP - SLU, WC, WOB
X
20163
9924
30087
50
-L- 178+00-184+97 LT&RT
60" CSP, CHANNEL CHANGE - SLS,WOA
X
38684
25634
64318
51
-L- 199+51-205+31
ROADWAY FILL, 66" RCP - SLR, WNZ
X
17316
9930
27247
52
ONLY IN PERMIT SET
53
-L- 209+51-217+29 LT & RT
54" RCP / 66" RCP - MILL BRANCH
X
27804
17778
45582
54
-L- 232+37-234+37 LT
54" WSP - SJ, WI, WJ
X
8694
5213
13907
55
ONLY IN PERMIT SET
56
ONLY IN PERMIT SET
57
-L- 246+11-248+25 LT & RT
60" WSP - SDD, WFF
X
15680
9394
25074
58
-L- 269+75-270+63 LT
36" WSP - SQ
X
10972
7749
18721
TOTALS*:
1 28492
1 14255
1 42747
1 181583
1 113030
1 2946131
0
10
PROJECT TOTALS*: 1 116816 1 55819 1 172635 1301854 1 166946 1468800 1 0 10
NOTES
REVISED 8/28/2019
12/4/2019
Revised 2018 Feb