Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG140448_COMPLETE FILE - HISTORICAL_20170125
STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. aOCTYPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ C� � � -I � � a YYYYMMDD i Permit Number NCG140448 Program Category NPDES SW Permit Type Ready Mix Concrete Stormwater/Wastewater Discharge COC Primary Reviewer rick.riddle Coastal SWRuIe Central Files: APS SWP _ 1 /26/2017 Permit Tracking Slip Status Project Type In review New Project Version Permit Classification COC Permit Contact Affiliation Permitted Flow RECEIVED Facility IOENTRAE Facility Name DWR SEW40ftor Region North Pointe Business Park Concrete Batch Plant Minor Mooresville Location Address County 4304 Northpointe Industrial Blvd Mecklenburg Charlotte NC 28216 Owner Facility Contact Affiliation Sue Werth PO Box 320 Denver NC 28037 Owner Name Owner Type Macleod Construction Inc Non -Government Owner Affiliation Bob Macleod PO Box 320 Dates/Events Denver NC 28037 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 12/15/2016 Regulated Activities _ Requested /Received Events Ready mixed concrete - stormwater discharges RO staff report received 1/11/17 RO staff report requested 116117 Outfall 1 Waterbody Name Streamindex Number Current Class Subbasin Stewart Creek 11-137-1-2 C 03-08-34 Energy, Mineral & Land Resources ENVIRONMENTAL QUALITY Bob Macleod MacLeod Construction, Inc. P.O. Box 320 Denver, NC 28037 Dear Mr. MacLeod. - ROY COOPER Governor MICHAEL S. REGAN Secretary TRACY DAVIS Director January 25, 2017 Subject: General Permit No. NCG 140000 MacLeod Construction, Inc. North Pointe Business Park Concrete Batch Plant COC NCG140448 Mecklenburg County In accordance with your application for a discharge permit received on December 15, 2016, we are forwarding herewith the subject certificate of coverage to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143- 215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage (COC) is not transferable except after notice to the Division of Energy, Mineral, and Land Resources. The Division may require modification or revocation and reissuance of the certificate of coverage. Please note that NCG140000 contains effluent limitations for process wastewater discharges (see Part 1V, Section D). Wastewater discharges must meet the requirements of these effluent limitations. An e_rceedance of any of these limitations is a violation of perniit conditions. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Energy, Mining, and Land Resources, or permits required by the Division of Water Resources, Coastal Area Management Act, or any other federal or local governmental permit that may be required. If you have any questions concerning this permit, please contact Richard Riddle at telephone number (919) 807-6375. Siinnc'}er�ely, 9- y2t"& for Tracy E. Davis, P.E., CPM cc: Mooresville Regional Office Central Files Stormwater Permitting Program Files Nothing Compares--,,- $State of North Carolina I Environmental Quality I Energy, Mineral and Land Resources 512 N. Salisbury Street 1 1612 Mail Service Center I Raleigh, North Carolina 27699-1612 919 707 9200 STATE OF NORTH CAROLINA DE" PARTMI N`1' OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINIIRAL, AND LAND RESOURCES GENERAL PERMIT NO, NCG140000 CERTIFICATE OF COVERAGE No. NCG140448 STORMWATER and WASTEWATER DISCHARGE-S NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, MacLeod Construction, Inc. is hereby authorized to discharge stormwater and process wastewater from a facility located at North Pointe Business Park — Concrete Batch Plant 4304 North Pointe Industrial Boulevard Charlotte Mecklenburg County to receiving waters designated as Stewart Creek, a class C water in the Catawba River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, 111, IV, and V of General Permit No. NCG140000 as attached. This certificate of coverage shall become effective January 25, 2017. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day .January 25, 2017. for Tracy E. Davis, P.E., Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission l'. 4j \ 1 - y - • 'LYE' r } * �'~ A "y�',.' iS _ �'• i•'�r 1, k "4.\ 1 r:r -C=r � s t r �J tl f`. � �` s,y . �'- � �,'S �k' �` t+ ��,�. � �_ � '•T' � � � J' pC—tom, y'r N 1 l�_�.t - M1 '' 'rt �C vss y>.i� ��i n � •' � �,r F� •� '�,�,,��y ,.�� ':-? �, liy ..,:�.1- '`'� :'y�� -�' ° �___ ��a tia' ''♦"Yi` ji }I-�` ! r � � \l"\ rr�'!.t - ,i 11 ';1� � �� ' ,�''rr�� J _ � y�fp` J �i f w : M� rf• } y �. y,]•"�= S'�Y. ' �, : tiY' t ✓ (.. -� 1 ' { "�'�'!"-'r��..-� � .� n " 'l \��-� M1r �' �tvhy,. '�� � 3�.r�' �. y ar ; � .;z•. -., i, �. � � { ��� �r 1� �rl � ��_ �-,�j I „5 �a�,,..' �,,}� r. ;�{�;'.:�,.- .5 �,•1,,� r�J'r�.'1 1 1, 2019 Iy�' \ - 1 S f j',• � Ad" K �F,.'s J, . �*5"`� •m,"v''`� W"on !}iT+`\ r `� �A. \ e� •.-• I .r`~ 1 F` 1 Li , / � ,�}. �€' � - f y. -t'J'+i �i :P :i fi,S �' ` ��'`,\ , .+�� � ,'�:j�' 1 �--^`� �\\ 11 t 1 j � f Will�Rms.Die n r � ✓ �� nw s r fr r`�" '� ¢•�• `\ J� J , �� , �, ' . T ..� i ,:\ �'F,1` 4�t �'SZ' �} i %% ry �\ r�A i �+.� k#Ec� �� •t,. }''l' 4.� } } s`.i�'„ �. ��,,ti �,�� . .ly�,i• fl� I',�`��\�� � � /,1C' YI � 1 •�, �}1) � � ! , il! r.',G,i ., �� � �: �.�-�% `+ y. ._ ti T s\ s '� _ r lit, ^\` { ;f�� JI 1 � � \ �_�r � 1�.QYa f �e " i�a::.��rr � �\\ � ��'•-• . ti t� : f Y�. � s �1: r,• � c ; `" I r / 1i11 '`` U c{ c 1r � r. r� ��� ��� � / '•� Y } t'],{ 4 a fSt` ' {' !�d,, k a ti•' ,y�: �`ry� t,1ti _ _I S_' r\� .� i �I � N \•�' �� -S � { t t• a�" .''�y" t.-`� ,! ,s ,5�^`.� s�, J ` r � y_.�;�!'�"`'��\�'`�1S'' � `'' '��_�� L\= r.%'.; O � •._.�I�-, � I '��'1 Mf����� r'l J ��'•.�i N S I 1 + ) \' � 1 ,.• �_ iS \\�'\V`} ��--� _ � ,� ! 1' . ✓ , / . ra�.�.,f If.- .�_ _�'e.!` tctfi z ^� \ \,,.�l.l� � � 5�t'-\`- � i � '��ei¢ � s'. J �lr /ri_�. �rlilfla ; � • �e`��� 5 ,� •� ,:y.;fiy� _ � �l" 1 ���""l l .ram � �n S ���t�, �t� ~ "�� �"� � } ��r R'ys, I ,� �i•''I' '+i'�: Rr `:i y�,� ,�;�{�"' ., ram_ _ � 1 \�\� - !} j ,r 9q 7 •� • �/•�` � � .,'i ! , t,l `- �� � '� "; x ?• �.' �F''' � ` 1 r ,. �, � �yy � •f' s L \i • y IC Z :^ �, l ,� " „`.'i\ �� 7 / 2091 r� � •in4 s -� � '� r � r�. Y} \ki5 � 'i', l`l � • �•- � � � t� .+� `� �L` .� . � } ` I � � '�t r� . f �, � �, n�,yy' s tyr. �,, `;� _ 'y,. �, L.n � Yti� r liir � f n 1 !� l`'-�/ V ..If 1..� ray r•6+;,^, 1 :i k�3 �C " tz.,lar ;�� ,;���Yv' ?�; L``� l'r,Y t \+." ( ����, i r`J` i}"-�� ,,: ;�•�� ''s ;4�t ,�' MacLeod Construction, S S �.'1• � y �, \_ 1 �' ///.� � �.rl� t• .., } tl �' JI I '� ,r� ^' h l tJf `_ ' 1 V ,} } r}�al: �\ f � I i:.—� 0 1 '•���'f'�} re,4ss } WC„�� / rl' � t — ;�' st,� � ;y ' r 1� 0 �.r •$`? �*' - s} tT b lIf �`^{ � Us � � , \� � f�)� �, ' � � sir• _ ° a1 • ;,� '�" .. )1"•1 �" r�5 i'� � � �;; '' k's w.. � � • + ~4� Y.. +. _w 4l.l�id"Y) � :1.. a J {., � `i eµr � rrl lsr NCG 140448 N W E S Map Scale 1:24,000 MacLeod Construction, Inc. North Pointe - Concrete Batch Plant Latitude: 350 16' 49" N Longitude: -800 52' 10" W County: Mecklenburg Receiving Stream: Stewart Creek Stream Class: C Index Number: 11-137-1-2 (Catawba River Basin) Facility Location ... :�'- ;, ... �.". :' �� _-:__-_.. .. k .. J _ ._ - -_ - -�,: �. .. .5. ._i�_._�_1.�. i __.�.- �_ � it-•. .i FES#3 RIP RAP APRON LENGTH 24,1' WIDTH (TOP) 6,0' WIDTH (BOTTOM) 3011' D50 = 7.5' v \ \ ------------------------------ - -- 26° - : 56 ---- .� - ��6 / OUTFALL D.S. 1 FES#4 INV 713.0 (*) CHAIN LIN RIP RAP APRON TREE PROTEC LENGTH 16.2' WIDTH (TOP) 6.0' BY THE URBA WIDTH (BOTTOM) 22.2' D50 =110' GRAVEL AND RIP RAP FILTER BERM PER CLDS.#30.12 DOUBLE HIGH HAZARD FENCE PER CLDS.#30.06B WITH ORANGE TREE PROTECTION FENCE ATTACHED TO THE OUTER SILT FENCE (*) X LLA �o .20 1 (A + 0 ROCK CHECK DAM 2' HIGH C 1 A_ FES#1 RIP RAP APRON LENGTH 21.0 WIDTH (TOP) 5.0' WIDTH (BOTTOM) B50 = 8. 5' T T o� o1- 41q ti �0O' yo<b 41 "C', GSF�o2 CO FES#1 RIP RAP APRON LENGTH 16,0' WIDTH (TOP) 5.0' WIDTH (BOTTOM) 20' D50 = 313' 94 Know what's below. a '. Call before you dig. "' '� ---CA=1 N.C. One -Call Center 7�o 1°° x Dial 811 or 1.800.632-4949 �fd v C). ,.. , `a ON _ caw o x RIP RAP LINED DITCH PER CLDS,#20,27 35'X35X SIGHT TRIANGLE TYP. ON BOTH SIDES I i NORTHPOi(6. c.n is iiivv J/LJL II/1L/� 731 ® \1 I g.0 F ok F SgoY ?"Flo ��R 'CO AgCH! IL REFER TO SHEET C4.1 FOR STORM DRAINAGE LEGEND: 740 ETC LIMITS OF DISTURBANCE SILT FENCE TEMPORARY DIVERSION DITCH EXISTING CONTOUR PROPOSED CONTOUR TREE PRESEVATION AREA STREAM SIDE ZONE OF SWIM BUFFER PROPOSED STORM DRAINAGE DRAINAGE AREA PROPERTY LINE EXISTING STORM DRAIN OVERHEAD UTILITIES 0 50 100 200 SCALE: 1 "=50' GRAPHIC SCALE IN FEET PRINTING SHEET SIZE 24X36 PCCO SUMMARY Original Parcel ID Number(s): 3910203 Development Type: Commercial Subject to PCCO? Y/N Y If NO, why? Watershed: Central Catawba Disturbed Area (ac): 6.6 Site Area (ac): 7.6 AC DA#1 DA#2 Total on -site Drainage Area (ac): 7.6 AC Existing Built -upon -area (SF): 0 SIF Existing BUA to be removed (SF): 0 SF Existing BUA to remain (SF): 0 SF Proposed New BUA (SF): 140,000 SF Proposed % BUA: 42.30% Density (High / Low) High Total Post -Project BUA for site: 140,000 SF Development or Redevelopment? Development Natural Area Required (ac): 0.0 AC Natural Area provided, total (ac): 0.0 AC Undisturbed Treed Natural Area Preserved (ac): 0.0 AC Total stream buffer protected on -site (ac). 0.0 AC Transit Station Area? Y/N N Distressed Business District? Y/N Y Mitigation Type (if applicable) 1 yr vol, 10 yr peak Natural Area mitigation? Y/N N Buffer Mitigation? Y/N N Total Phosphorous Mitigation? Y/N N GENERAL NOTES: �.., 2 O MANSOU = EDLI CONSULTMia 1. BEFORE YOU DIG, CONTACT NC CALL ONE 811 FOR FIELD LOCATION OF EXISTING UNDERGROUND UTILITIES. 2. IF DISCREPANCIES DEVELOP BETWEEN THE PROPOSED GRADES, AS SHOWN ON THE PLAN, AND THE EXISTING GROUND SURFACE, THE CONTRACTOR, WITH PRIOR APPROVAL OF THE OWNER, SHALL MAKE GRADING ADJUSTMENTS NECESSARY TO MAINTAIN THE GENERAL INTENT OF THE PLAN DESIGN. 3. WHERE UNSUITABLE MATERIAL IS ENCOUNTERED, THE CONTRACTOR SHALL REMOVE ALL UNSUITABLE MATERIALS AND BACKFILL WITH STRUCTURAL FILLAS DIRECTED BY SOIL ENG. UNSUITABLE 4. ALL SUBGRADES MUST BE PROOF ROLLED PRIOR TO PLACEMENT OF CURB AND GUTTER OR PAVEMENT. 5. ALL SPOT ELEVATIONS ARE TO TOP OF PAVEMENT OR FINISHED GRADE UNLESS OTHERWISE NOTED. W 1:4 C)Fax I;J 1515 MOCKINGBIRD SUITE 802 Charlotte, 289 Phone 704 672 704 672- E C. rO 560 562 6. PROTECT IMPROVEMENTS ON ADJOINING PROPERTIES AND RESTORE ALL DAMAGED IMPROVEMENTS TO THEIR ORIGINAL CONDITION. 7. BLASTING IS NOT PERMITTED WITHOUT PRIOR APPROVAL FROM THE CITY OF CHARLOTTE O [i This drawing and design shown are the property of Manso r Edlin Consulting. The reprodu tion, editing or other use of thi BURNING IS NOT PERMITTED. 8 FILL MATERIALS SHALL BE PLACED IN LAYERS NOT MORE THAN 8 INCHES AND COMPACTED TO 98% STD. PROCTOR. J drawing without written con 3ent is prohibited and infringerno nt will be subject to legal act on. 9. ALL TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 100% PERCENT PROCTOR UNDER PAVEMENT AND 95% PROCTOR OUTSIDE PAVEMENT. 10. ALL AREAS SHALL BE GRADED WITHIN OX OF PROPOSED GRADE SHOWN ON PLANS. 11. ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION OF THE CITY'S EROSION CONTROL ORDINANCE AND IS SUBJECT TO FINE. 12, STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING IS NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS AND ESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTION SEQUENCE SHOWN ON THE [� O I� = SEAL SEA L - = = 15782 PLAN. ALL GRADED AREAS AND SLOPES MUST BE SEEDED AND MULCHED WITHIN 21 DAYS. 13. NO SOIL DISTURBANCE OR COMPACTION, CONSTRUCTION MATERIALS, TRAFFIC OR BURIALfINEE�;,���`� PROTECTION ZONE. 14. TREE BARRICADES MUSTPITS ALLOWED IN THE TREE BE INSTALLED BEFORE ANY GRADING/CONSTRUCTION AND NOT REMOVED UNTIL AFTER FINAL INSPECTION BY URBAN FORESTER. 15. TREE PROTECTION BARRICADES MUST MEET OR EXCEED TREE ORDINANCE STANDARDS. Z' 115.1E4���� �V , 16. TOP SOIL & RESIDUAL CUT MATERIALS SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 1 0 - 29 - 201 6 17. GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION OF THE CITY'S EROSION CONTROL ORDINANCE AND ISSUBJECT TO A FINE. PROJECT NUMBER 08,06.2015 C 18. FAILURE TO SCHEDULE AN ONSITE MEETING WITH THE CITY'S EROSION CONTROL COORDINATOR 48 HRS. PRIOR TO ANY LAND DISTURBING ACTIVITY IS A VIOLATION OF CHAPTER 18 OF THE CITY CODE AND IS SUBJECT TO FINE. DESIGN HAIR BY 19. ON SITE BURIAL PITS REQUIRE AN ON -SITE DEMOLITION LANDFILL PERMIT FROM ZONING ADMINISTRATOR. APPROVED By ME 20. SLOPES SHALL BE GRADED NO STEEPER THAN 2:1 21. REINFORCED CONCRETE PIPE SHALL BE CLASS III UNLESS OTHERWISE NOTED 22. MINIMUM COVER FOR ALL PIPE IS (2.0) FEET DRAWN ey HAIR Dde 08.06.2015 CITY OF CHARLOTTE NOTES: DIGITAL FILE 1. COORDINATE ALL CURB AND STREET GRADES IN INTERSECTION WITH INSPECTOR. 2015PROJECT\MACLEOD NORTH POINT BIS. PARI 2. ALL ROAD IMPROVEMENT ON ROAD DRIVE SHALL BE COORDINATED WITH ENGINEERING DEPARTMENT PRIOR TO CONSTRUCTION. 3. DEVELOPER WILL PROVIDE STREET SIGNS PER CMLDS# 50.05 (9" SIGNS ONLY) 7 4. SIGHT TRIANGLES SHOWN ARE THE MINIMUM REQUIRED. 5. DIRECT VEHICULAR ACCESS TO LOT 11-B FROM 1-77 IS PROHIBITED 6 6. APPLICATION OFDA TACK COATN AYSBEEREQUIREDTHE ARTNTERSE TIONS/OR rj THESE REQUIREMENTS WILL BE ESTABLISHED BY THE INSPECTOR AND BASED ON 4 FIELD CONDITIONS. 7. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. 8. IN ORDER TO ENSURE PROPER DRAINAGE, KEEP A MINIMUM OF 0.5% SLOPE ON 3 2• THE CURB. 9. SUBSURFACE DRAINAGE FACILITIES MAY BE REQUIRED IN THE STREET RIGHT- OF -WAY IF DEEMED NECESSARY BY THE INSPECTOR. 10. CURB AND GUTTER SHOWN ON PLANS ALONG NA ROADWAY DRIVE MAY BE ADJUSTED 1, BASED UPON FIELD STAKING BY CITY ENGINEERING, ASSOCIATED STORM DRAINAGE MAY ALSO REQUIRE MODIFICATION BASED UPON FIELD CONDITIONS. 11. THE PURPOSE OF THE STORM DRAINAGE EASEMENT (SOE) IS TO PROVIDE STORM WATER CONVEYANCE AND ANY STRUCTURES AND/OR OBSTRUCTION TO STORM WATER FLOW IS PROHIBITED. ISSUE 12. HIGH -DENSITY POLYETHYLENE (HOPE) STORM DRAINAGE PIPE INSTALLED WITHIN EXISTING OR PROPOSED PUBLIC STREET RIGHT-OF-WAY MUST BE APPROVED BY THE CITY'S INSPECTOR PRIOR TO ANY BACKFILL BEING PLACED BACKFILL MATERIAL MUST BE APPROVED BY THE CITY INSPECTOR PRIOR TO PLACEMENT OF THE 7 MATERIAL WITHIN THE PUBLIC STREET RIGHT-OF-WAY. 13. THE DEVELOPER SHALL MAINTAIN EACH STREAM, CREEK, OR BACKWASH CHANNEL IN AN UNOBSTRUCTED STATE AND SHALL REMOVE FROM THE CHANNEL AND BANKS 6 OF THE STREAM ALL DEBRIS, LOGS, TIMBER, JUNK AND OTHER ACCUMULATIONS. 14. ANY BUILDING WITHIN THE 100+1 STORM WATER ELEVATION LINE IS SUBJECT TO THE RESTRICTIONS 5 OF THE (CITY OF C HARLOTTE/M ECK LENG BURG COUNTY) SUBDIVISION ORDINANCE, SECTION 7.200.8. PE SEALED SHOP DRAWINGS FOR RETAINING WALL MUST BE SUBMITTED TO CITY ENGINEER PRIOR TO CONSTRUCTION. 4 3 15. ANY CONSTRUCTION OR USE WITHIN THE FUTURE CONDITIONS FLOOD FRINGE LINE IS SUBJECT TO THE RESTRICTIONS IMPOSED BY THE FLOOD WAY REGULATION OF THE CITY OF CHARLOTTE AND MECKLENBURG COUNTY. 16. ALL OPENINGS ( E,G,DOORS, WINDOWS, VENTS) IN STRUCTURES BUILT ON LOT#S----------- 2. 1. PER CITY ENGINEERING REVIEW CO MENTS 10. .2016 SHOULD BE LOCATED A MINIMUM OF ONE FOOT ABOVE THE ADJACENT FINISHED GROUND SURFACE ( APPLIES TO LOTS WHICH MAY EXPERIENCE SIGNIFICANT OVERLAND FLOW NOT CONSIDERED IN THE 100+1 FLOOD ANALYSIS.) R E\/ I S 1 O N 17. PE SEAL SHOP DRAWINGS FOR RETAINING WALL MUST BE SUBMITTED TO CITY ENGINEER PRIOR TO CONSTRUTION. 18. "AS -BUILT' DRAWINGS AND PLANS OF THE STORM DRAINAGE SYSTEM, INCLUDING DESIGNED DITCHES, MUST BE TO THE ENGINEERING DEPARTMENT INOACC RDA CE TO SUBFINAL TIHHE ON CITY UBDIVISIONNO DINANCE.TY MACLEOD 19. PRIOR TO INSTALLATION, PE SEALED SHOP DRAWINGS FOR UNDERGROUND DETENTION SYSTEMS MUST BE FURNISHED TO CITY OF CHARLOTTE ENGINEERING FOR APPROVAL. CONSTRUCTION 20. PRIOR TO CO, SURVEYOR SEALED AS -BUILT DRAWINGS OF UNDERGROUND DETENTION P.O. BOX 320 21. PRIOR TO PLAT RECORDATION, OFF -SITE R/W AND / OR CONSTRUCTION EASEMENTS RE REQUIRED DENVER, NC 28037 TO BE OBTAINED ACCORDING TO THE QUIEDUNES OF THE " OFF -SITE R/W ACQUISITION PROCESS THESE NEEDED R/W AND CONSTRUCTION LIMITS ARE CLEARLY SHOWN ON THE ROADWAY IMPROVEMENT PLAN. PHONE#: 704-483-3513 FAX#: 704-483-357 22. THE DEVELOPER SHALL CONTACT THE CHARLOTTE DEPARTMENT OF TRANSPORTATION (GUS JORDI, 704-336-7086) TO IDENTIFY ANY CONFLICTS WITH TRAFFIC SIGNAUZATION EQUIPMENT, 60-90 DAYS WILL BE REQUIRED TO COORDINATE RELOCATION. DEVELOPER SHALL BE RESPONSIBLE FOR ALL RELATED RELOCATION COST AND / OR ANY REPAIR COST CAUSED BY THE CONTRACTOR / DEVELOPER 23. CERTIFICATION AND STREET CUT PERMITS ARE REQUIRED FOR UTILITY CUTS ON CITY STREETS. ALLOW 7 DAYS PROCESSING FOR PERMIT. FOR INFORMATION CONTACT CHARLOTTE DEPARTMENT OF TRANSPORTATION CONCRETE (704-336-4025) BATIC 24. PER SECTION 18-175(e) OF CITY CODE AND SECTION 10.0 OF THE CITY'S POST CONSTRUCTION CONTROLS ADMINISTRATIVE MANUAL, ALL REQUIRED NATURAL AREAS AND/ OR POST CONSTRUCTION CONTROLS PLANT EASEMENTS (PCCEs) MUST BE RECORDED PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY 25 NON-STANDARD ITEMS ROW ENCROACHMENT AGREEMENT RREEMENTW/THE (S, IRRIGATION SYSTEMS, ETC.) IN EREQUIRE ROW (CHARLOTTE DEPARTMENT T OFTRANSPOR TRANSPORTATION/NORTH 4304 NORTHPOIN E CROLINA DEPARTMENT OF TRANSPORTATION) BEFORE INSTALLATION. 26. SIDEWALK WITHIN THE CITY'S R/W THAT REQUIRES REPLACEMENT AS PART OF THE DEVELOPMENT INDUSTRIAL BLVD. AND /OR STREET IMPROVEMENTS SHOULD BE PLACED IN SUCH A WAY AS TO MINIMIZE THE DURATION OF THE SIDEWALK CLOSURE TO THE EXTENT FEASIBLE. THE DEVELOPER SHOULD CHARLOTTE NC MAKE EVERY ATTEMPT TO HAVE SIDEWALK REPAIRED AND REOPENED FOR PUBLIC USE WITHIN 30 DAYS OF REMOVAL. 27. ANY WORK WITHIN THE CITY'S R/W THAT REQUIRES CLOSURE OF THE SIDEWALK OR TRAVEL LANE FOR LESS THAN 30 DAYS REQUIRES A W/W USE PERMIT. TRAFFIC CONTROL PLANS FOR ANY PARCEL #039102103 SIDEWALK OR TRAVEL LANE CLOSURES MUST SUBMITTED AS PART OF THE R/W USE PERMIT REQUEST. TRAFFIC CONTROL PLANS MUST BE IN ACCORDANCE WITH CDOT'S WORK AREA TRAFFIC CONTROL HANDBOOK (WATCH) AND MUST BE REVIEWD AND APPROVED. CONTRACTOR SHALL CONTACT CDOT AT LEAST 5 BUSINESS DAYS IN ADVANCE OF BEGINNING OF WORK AT (704)432-1562 28. RIGHT -OF-WAY CLOSURES LONGER THAN 30 DAYS REQUIRE A R/W LEASE AGREEMENT WHICH WILL INCLUDE THE SUBMITTAL OF A TRAFFIC CONTROL PLAN. TRAFFICE CONTROL PLANS REQUIRE `p M �C N FIGURE 2 THROUGH A LEASE AGREEMENT MAY BE DIFFERENT FROM THE ONE REQUIED DURING THE LAND DEVELOPMENT PLAN REVIEW AND ARE SUBJECT TO REVISIONS. THE REVISED TRAFFIC CONTROL PLANS MUST BE SUBMITTED AS PART OF THE LEASE AGREEMENT PROCESS FOR APPROVAL PRIOR TO START OF R/W CLOSURES. CONTRACTOR SHALL CONTACT CDOT AT (704) 336-8348 W N GRA PL ING N 29. CONSTRUCTION STAGING WITHIN CITY R/W LASTING MORE THAN 30 DAYS REQUIRES A R/W LEASE AGREEMET.CONTRACTOR SHALL CONTACT CDOT AT (704) 336-8348 �' �W z C4.0 U0 I, Al Division of Energy, Mineral and Land Resources Land Quality Section NCDENRNational Pollutant Discharge Elimination System Nowm C�r Dmwrwurr or ERYIRONM£Nr uo Nuys - REgpi,610E'- NCG140000 'NOTICE OF INTENT National Pollutant Discharge Elimination System application for coverage under General Permit NCG140000: Ui Cr STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with activities classified as: SIC (Standard Industrial Classification) Code: 3273 and like activities - Ready Mixed Concrete This NOI maybe an application to discharge process wastewater. NCG140000 contains effluent limitations for process wastewater discharges. Wastewater discharges must meet the requirements of these effluent limitations. An exceedence of any of these limitations will result in a violation of the permit conditions. For questions, please contact the DEMLR Central Office or Regional Office in your area. (See page 6} (Please print or type) 1) Mailing address of ownerloperator (official address to which all permit correspondence will be mailed): (Please print or type all entries in this application form.) Legal Owner Name MacLeod Construction, Inc. (Please attach the most recent Annual Report to the NC Secretary of State showing the current legal name. Alternatively this permit can be given to an individual.) Signee's Name (as signed for in question 29 below) Bob MacLeod Street Address P.O. Box 320 City Denver State NC ZIP Code 28037 Telephone No. (704) 483-3580 x 2312 Email rmac macleodconstruction.com Alternate Contact Name Sue Werth Email (if different) swerth(�macleodconstruction.com Alternate Contact Telephone (if different) (704) 483-3580 x_2302 2) Location of facility producing discharge: Facility Name MacLeod Construction, Inc. — North Pointe Business Park Concrete Batch Plant Facility Contact Plant Manager to be Named Street Address 4304 North ointe Industrial Boulevard City Charlotte State NC ZIP Code 28216 County Mecklenburg Telephone No. Fax. 3) Physical location information: Please provide narrative directions to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). From 1-85140 north end of Charlotte take Exit 37 Beatties Ford Road north two blocks to North Hoskinas Road and turn left: follow North Hoskinqs Road to Northoointe Industrial Boulevard and turn right; site is anDroximateiv I/A-mile on riqht hand side. (A copy of a county map or USGS quad sheet with facility clearly located on the map is a required part of this application.) — F ig u re 1 4) Latitude 35.280356 Longitude-80.869522 5) This NPDES Permit Application applies to the following (check all that apply): 0 New or Proposed Facility Date operation is to begin 2017 ❑ Existing Facility SWU-229-11032011 Permit # Page 1 of 7 Last revised 712114 NCG140000 N.O.I. 6) Consultant's application information: Consultant: Mark Cramer, P.E. Consulting Firm: The El Group, Inc. (El) Mailing Address: 2101 Gateway Centre Blvd Suite 200 City: Morrisville State: NC Zip Code: 27560 Phone: (919) 459-5229 Fax: (919) 657-7551 Email: mcramer(r-)eil.com Mark Cramer, P.E. Senior EN neer 2101 Ga mv, Cc -,Ire Bhd-S.iw M merge-dE-- ,0.h(-y0bap27560 1---U1"VV-c" office: 919.4593229 Dccu1>.xwn.�l Hca�:h ran: 919 fi57 7551 Sye,xy MoWc! 919.62i 1913 I [.a'ning ma�d-.,z.alal cvm urww.ei2.[om J 7) Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility: SIC Code: 3273 8) Provide a brief description of the types of industrial activities and products produced at this facility: (Attach a site diagram showing the process areas present at this facility.) — Figure 2 Central Mix Concrete Plant Stormwater Discharge, Wastewater Treatment & Discharge and Permitting Information 9) Discharge points / Receiving waters: Number of discharge points (ditches, pipes, channels, etc.) that convey stormwater and/or wastewater from the property: Stormwater-only: Wastewater -only: Wastewater Commingled with Stormwater: 1 For new facilities: Expected date of commencement of discharge: 2017 What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater and/or wastewater discharges end up in? Stewart Creek Receiving water classification(s), if known: C If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). Will this facility discharge wastewater to SA (Shellfishing) waters? ❑ Yes x❑ No Note: Discharge of process wastewater to receiving waters classified as WS-II to WS-V or SA must be approved by the N.C. Division of Water Resources, Public Water Supply Section. If DWR does not approve, coverage under NCG140000 cannot be granted. No new discharges of process wastewater are permitted in receiving waters classified as WS-I or freshwater ORW. 10) Each applicant shall provide the following information (attach additional sheets as necessary): 11) Two (2) site plans depicting the facility or site with numbered outfalls which indicate stormwater and wastewater outfalls. The plans shall legibly show. at a minimum, (existing or proposed): — Figure 2 c Outline of drainage areas with topographical lines and features o Stormwater/wastewater treatment structures o Location of numbered stormwater/wastewater outfalls (corresponding to which drainage areas) o Runoff conveyance structures o Areas and acreage where materials are stored o Impervious area acreages o Location(s) of streams and/or wetlands the site is draining to, and any applicable buffers o Site property lines, North Arrow, and bar scale o If applicable, the 100-year floodplain line Page 2 of 7 SWU-229-07122011 Last revised 7l2I14 NCG140000 N.O.I. o Acreage of each stormwater and wastewater topographical area o Each of the facilities' wastewater or stormwater source and discharge structures and each of its hazardous waste treatment, storage, or disposal facilities o Site location (insert) Site plans shall be 24" x 3 6 " in size. • Line drawing and description: Aline drawing of the water flow through the facility. A pictorial description of the nature and amount of any sources of water and any collection and treatment measures. • A narrative description and identification of each type of process, operation, or production area which contributes wastewater to the effluent for each outfall, and a description of the treatment the wastewater receives (or will receive), including the ultimate disposal of any solid or fluid wastes other than by discharge. Processes, operations, or production areas may be described in general terms (e.g. "ash silo"). — One outfall for Batch Concrete Plant. 12) Does the applicant have any unresolved Notice of Violations (NOVs)? 0 No ❑ Yes Wastewater: 13) What types of wastewater does your facility generate or discharge? Type of Authorized Wastewater Generate Discharge Sent to WW Treatment System Vehicle and equipment cleaning (VE) 0 ❑ Wetting of raw material stockpiles (RM) 0 0 ❑ Mixing drum cleaning MD) 0 0 ❑ Further explanation, if necessary: 14) Will your facility spray -down or actively wet aggregate piles? ❑ No 0 Yes 15) Does the facility use any of the following on site? ❑ Phosphorus -containing Detergents ❑ Non -Phosphorus -containing Detergents ❑ Brighteners 0 Other Cleaning Agents -- SDSs Attached ❑ Other: 16) Are wastewater treatment facilities planned in the 100-year flood plain? 0No El Yes 17) Does your facility use or plan to use a recycle system, or recycle components in your treatment system? 0 Yes ❑ No If yes, what size storm event is the system designed to hold before overflowing? (for example, 10-yr, 24-hr) 1-year, 24-hour rainfall event volume and 10-Year, 6-hour rainfall event volume Page 3of7 SWU-229-07122011 Last revised 712114 NCG140000 N.O.I. 18) Will your facility build a closed -loop recycle system that meets design requirements in 15A NCAC 02T 1000 and hold your facilities' working volume'? ❑ Yes N No Will your facility discharge wastewater to surface waters? 0 Yes ❑ No If the facility's treatment system meets the design requirements of 15A NCACO2T .1000 (including holding the 25-year, 24-hour storm plus one foot of freeboard), holds the working volume of your site, and does not discharge wastewater to surface waters, you may not be required to obtain an NPDES permit for wastewater discharges. If you believe this is the case, please contact DEMLR's Aquifer Protection Section Land Application Unit Central Office Supervisor or staff (1636 Mail Service Center, Raleigh, NC 27699-1636) for more information on obtaining the necessary permits or approvals. If you will discharge wastewater or stormwater to surface waters, please continue to apply for a permit to discharge associated with ready -mixed concrete or like operations under NCG 140000. For further questions, please contact DEMLR's Stormwater Permitting Unit Staff. 19) A wastewater treatment alternatives review is required by 15A NCAC 2H.0105 (c)(2) for any new or expanding water pollution control facility's discharge in North Carolina. You may attach additional sheets. a) What wastewaters were considered for this alternatives review? ❑x VE 0 RM ❑X MD b) Connection to a Municipal or Regional Sewer Collection System: i) Are there existing sewer lines within a one -mile radius? ..................................... ❑X Yes ❑ No (1) If Yes, will the wastewater treatment plant (WWTP) accept the wastewater? .... ❑ Yes 0 No See attached e-mail from Doug Wise of Charlotte Water dated October 16, 2015. (a) If No, please attach a letter documenting that the WWTP will not accept the wastewater. (b) If Yes, is it feasible to connect to the WWTP? Why or why not?* c) Closed -loop Recycle System (must meet design requirements of 15A NCAC 2T .1000): Are you already proposing a closed -loop recycle system (CLRS)? ❑ Yes Z No (1) If Yes, contact DEMLR's Aquifer Protection Section's Land Application Unit (2) If No, is this option technologically feasible (possible)? Why or why not?*Available land does not provide sufficient storage capacity. _ (3) If No, is it feasible to build a CLRS on your site? Why or why not?* Available land does not provide sufficient storage ca acit . (4) What is the feasibility of building a CLRS compared to direct surface water discharge?* economically not feasible and sufficient land not available for required storage capacity. Retaining drainage from entire site would also significantly reduce recharge to Stewarts Creek. d) Surface or Subsurface Disposal System (e.g., spray irrigation): i) Is a surface or subsurface disposal technologically feasible (possible)? ....................El Yes 0 No Why or Why not? Land restricted. ii) Is a surface or subsurface disposal system feasible to implement?* .................. ......... ❑ Yes 0 No Why or Why not? Land restricted. t See DWQ's Aquifer Protection Section Land Application Unit's Water Balance Calculation Policy for more information, on DWQ LAU's website http://portal.ncdenr.org/web/w(llaps/lau/policies for more information. Page 4 of 7 SWU-229-07122011 Last revised 712114 NCG140000 N.O.I. iii) What is the feasibility of employing a subsurface or surface discharge as compared to a direct discharge to surface waters?* Land restricted. e) Direct Discharge to Surface Waters: Is discharge to surface waters the most environmentally sound alternative of all reasonably cost-effective options of the wastewaters being considered?*... 0 Yes ❑ No i) If No, contact DEMLR's Land Application Unit to determine permitting requirements. f) If this review included all wastewater discharge types, would excluding some types (e.g. raw stockpile wetting) make any of the above non -discharge options feasible? .............. El Yes 0 No ` You may be asked to provide further information to support your answers to these questions after the initial review. Feasibility should take into account initial and recurring costs. Storm wa ter. 20) Does this facility employ any best management practices for Stormwatercontrol? ❑ No 0 Yes If yes, please briefly describe: Retention pond and settling system standard for batch concrete plants. 21) Does this facility have a Stormwater Pollution Prevention Plan? x❑ No ❑ Yes If yes, when was it implemented? SWPPP under development at time of development of this Notice of Intent (NOO for coverage under NCG140000, prior to construction. SWPPP will be finalized and implemented_ upon_ startup of operation. 22) Are vehicle maintenance activities (VMA) occurring or planned at this facility? ❑ No ❑X Yes If yes, does your VMA area discharge into your wastewater treatment device? ❑ No 0 Yes Other/Permitting: 23) Does this facility have a Division of Land Resources Erosion & Sedimentation Control (E&SC) Permit? 0 No ❑ Yes If yes, list the permit numbers for all current E&SC permits for this facility: Applied for and permit is pending from City of Charlotte. See attached City of Charlotte e-mail receipt. 24) Is your facility subject to Phase II Post -Construction Area? 0 Yes ❑ No If yes, who is the permitting authority? City of Charlotte is within Phase II Post -Construction Area; however, distressed business district exempt from certain post construction stormwater ordinance requirements. See Post -Construction Control Ordinance PCCO Summary in attached Figure 2 25) Is your facility located in one of the 20 Coastal Counties? ❑ Yes 0 No Is your facility adding more than 10,000 ft2 of built -upon area or CAMA Major Permit? ❑ Yes ❑ No 26) Is your facility discharging wastewater (treated or untreated) such as water from wetting of aggregate piles, drum rinse -out, or vehicle and equipment cleaning to a stormwater BMP? ❑ No 0 Yes If yes, please attach your approval from the permitting authority to do so. — DEQ is the permitting authority. 27) Does this facility have any other NPDES permits? 9 No ❑ Yes If yes, fist the permit numbers for all current NPDES permits for this facility: 28) Does this facility have any Non -Discharge permits (ex: recycle permits)? Z No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 29) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? Page 5 of 7 SWU-229-07122011 Last revised 712114 NCG140000 N.O.I. ❑x No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? ❑X No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? 0 No ❑ Yes d) Type(s) of waste: How is material stored: _ Where is material stored: How many disposal shipments per year: Name of transport 1 disposal vendor: _ Vendor address: Final Checklist This application will be returned as incomplete unless all of the following items have been included: 0 Check for $100 made payable to NCDENR. 0 This completed application and all supporting documentation. See Question 10. 0 If an Erosion & Sedimentation Control (E&SC) Plan is required from Division of Land Resources (DLR) or local designee: documentation verifying applicant has developed and submitted that Plan to the governing agency (required per 15A NCAC 02H .0138). — Applied for and permit is pending from City of Charlotte. See attached City of Charlotte e-mail receipt. 0 Two (2) site plans depicting the site plant with numbered outfalls which indicate stormwater and wastewater outfalls. See Question 10 — Figure 2 ❑ A county map or USGS quad sheet with location of facility clearly marked. — Figure 1 30) Signatory Requirements (per 40 CFR 122.22) All applications, reports, or information submitted to the Director shall be signed and certified. a. All notices of intent to be covered under this General Permit shall be signed as follows: (1) For a corporation: by a responsible corporate officer. For the purpose of this permit, a responsible corporate officer means: (a) a president, secretary, treasurer or vice president of the corporation in charge of a principal business function, or any other person who performs similar policy or decision making functions for the corporation, or (b) the manager of one or more manufacturing production or operating facilities employing more than 250 persons or having gross annual sales or expenditures exceeding 25 million (in second quarter 1980 dollars), if authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures. (2) For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or (3) For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. Page 6 of 7 5WU-229-07122011 Last revised 712/14 NCG140000 N.O.I. Certification: North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact In a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate arty recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may Include a fine not to exceed ten thousand dollars (S10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Bob MacLeod Title: President L Z (Sign re of Applicant) (Date Signed) Notice of Intent must be accompanied by a check or money order for $100.00 made payable to: NCDENR Mail the entire package to: Stormwater Permitting Unit Program Division of Energy, Mineral and Land Resources 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee the Issuance of an NPDES permit. For quest5ons, please contract the DEMLR Regional Office for your area. DEMLR Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ...(252) 946- 481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office ......... (919) 807-6300 Page 7 of 7 SM-229-07122011 Last revised 712114 Energy, Mineral & Land Resources ENVIRONMENTAL QUALITY Bob MacLeod MacLeod Construction, Inc. P.O. Box 320 Denver, NC 28037 Dear Mr. MacLeod: ROY COOPER Governor MICHAEL S. REGAN Secrerary TRACY DAVIS oirecror January 25, 2017 Subject: General PermitNo.NCG140000 MacLeod Construction, Inc. North Pointe Business Park Concrete Batch Plant COC NCG140448 Mecklenburg County ' In accordance with your application for a discharge permit received on December 15, 2016, we are forwarding herewith the subject certificate of coverage to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143- 215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage (COC) is not transferable except after notice to the Division of Energy, Mineral, and Land Resources. The Division may require modification or revocation and reissuance of the certificate of coverage. Please note that NCG 140000 contains effluent limitations for process wastewater discharges (see Part IV, Section D). Wastewater discharges must meet the requirements of these effluent limitations. An exceedance of any of these limitations is a violation of permit conditions. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Energy, Mining, and Land Resources, or permits required by the Division of Water Resources, Coastal Area Management Act, or any other federal or local governmental permit that may be required. If you have any questions concerning this permit, please contact Richard Riddle at telephone number (919) 807-6375. Sincerely, ORIGINAL SIGNED BY MICHEAL F i�N�[ L for Tracy E. Davis, P. , cc: Mooresville Regional Office Central Files Stormwater Permitting Program Files Nothing Compares.`. 55tate of North Carolina I Environmental Quality I Energy.Mineral and land Resources 512 N. Salisbury Street 1 1612 Mail Service Center I Raleigh, North Carolina 27699-1612 919 707 9200 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140448 STORMWATER and WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, MacLeod Construction, Inc. is hereby authorized to discharge stormwater and process wastewater from a facility located at North Pointe Business Park — Concrete Batch Plant 4304 North Pointe Industrial Boulevard Charlotte Mecklenburg County to receiving waters designated as Stewart Creek, a class C water in the Catawba River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, I1, II1, IV, and V of General Permit No. NCG140000 as attached. This certificate of coverage shall become effective January 25, 2017, This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day January 25, 2017. ORIGINAL SIGNED BY MICHEAL F RANDALL for Tracy E. Davis, P.E., Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission ROY COOPER Energy, Mineral and Land Resources ENVIRONMENTAL QUALITY Mr. Zah id Khan Mooresville Regional Office 610 East Center Avenue/Suite 301 Mooresville, North Carolina 28115 Dear Mr. Khan: January 6, 2017 Governor WILLIAM G. ROSS, JR. Acting Secretary TRACY E. DAVIS Director Subject: General Permit No. NCG140000 North Pointe Business Park Concrete Batch Plant COC No. NCG140448 Mecklenburg County Enclosed is a copy of the site plan for the above NOI MacLeod Construction North Pointe Business Paris Concrete Plant for application for your review. I previously sent you the NOI and location map via email. If you need any more information, please give me a call at telephone number (919) 807- 6375 or email at rick.riddle@ncdenr.gov. Thanks, Richard Riddle, Jr. Stormwater Engineer NC Division of Energy, Mineral and Land Resources Attachments State of North Carolina I Environmental Quality I Energy, Mineral and Land Resources 1612 Mail Service Center 1 512 North Salisbury Street I Raleigh, NC 27699-16t2 919 707 9200 T December 14, 2016 Stormwater Permitting Unit Program North Carolina Department of Environmental Quality (DEQ) Division of Energy, Mineral and Land Resources (DEMLR) 1612 Mail Service Center Raleigh NC 27699-1612 AEI Re: National Pollutant Discharge Elimination System (NPDES) Application for Coverage Under General Permit NCG140000 for MacLeod Construction — North Pointe Business Park Concrete Batch Plant Dear Sir or Madam: The EI Group, Inc. (ET) is submitting the enclosed application for coverage under the NPDES General Permit NCG140000. Enclosed are the completed application forms, two copies of a site plan (Grading Plan), a USGS quad sheet, plus supporting documentation. Also enclosed is the check for the $100.00 fee. Please review the enclosed application and supporting documentation, and issue Certificate of Coverage. MacLeod Construction would like to begin construction around January 21, 2017, and begin operation in late March 2017, if possible. Thank you for your prompt attention to this matter. Please feel free to direct questions regarding the enclosed application to me at (919) 459-5229 or mcramer@ei Lcom. Regards, THE El GROUP, INC. 7 4'— Mark Cramer, P.E. Senior Engineer Enclosure: Completed DEMLR NCG140000 NOI Application Forms and Supporting Documentation R CEI` PD r" ?% 1 � OU'%I'ITY S-IORf�r1tlAt�+� f'�ht'�1�ilNG A Mark Cramer rom: Wise, Douglas <dwise@ci.charlotte.nc.us> Sent: Friday, October 16, 2015 8:53 AM To: Mark Cramer Subject: Discharge of stormwater to sewer Attachments: ShortWWS_Update 2015.doc Mr. Cramer, Below is a link that will take you to the Charlotte City Code. Chapter 23, Section 79(b)(14) specifically prohibits the discharge of stormwater into our collection and treatment system unless specifically authorized. As I mentioned during our phone conversation earlier this morning, CLTWater dedicates an enormous amount of resources to keep stormwater from entering our system. In the event that there is no option for your company to handle this water otherwise, we may be able to permit your discharge. As I explained, this would likely require you to apply for a permit, install appropriate pretreatment and monitoring equipment, and perform periodic sampling events. As we discussed, since the project is still in the development stage, it would be best if process wastewaters could be recycled in the product and stormwater managed separately. Additionally, I am attaching a short survey that we routinely use to document discharges from Industrial users in the CLTWater service area. Please a take a few moments and complete this as best you can. If you have any questions don't hesitate to contact me. Again, thanks for your time on the phone this morning. https:/Zwww,municode.com/library/nc/charlotte/codes/code of ordinances?nodeld=PTIICOOR CH23WASEINWADIRE_ ARTIIIWADIRE 523-79PRDIST Doug Wise / Environmental Compliance Supervisor CHARLOTTE WATER 4222 Westmont Drive / Charlotte, NC 28217 P:704-336-4729 / C:704-249-1866 / charlottewater.oro From: MEdlin4583(@aol.com To: Mark Cramer Subject: Fwd; File submission successful for LDC-2016.00178 - ErosionControl-Storm+Wat... Date: Monday, December 12, 2016 8:45:44 AM Mark, The email below is a confirmation we typically receive for the City of Charlotte Engineering when we submit or re -submit plans for their review. This email regarding re -submittal or Macleod plans. Mansour Mansour Edlin Consulting 1515 Mockingbird Lane Suite 802 Charlotte, NC 28209 704-672-1560 office 704-965-4800 cell From: AccelaDocumentService@accela.com To: medlin4583@aol.com Sent: 812612016 1.56:53 A.M. Eastern Standard Time Subj. File submission successful for LDC-2016-00178 - Erosion Control-Storm+Water+Calcs%181%19.pdf Your recent file upload has been successfully submitted to: Charlotte Production. The following is the summary of the file uploaded: File name: Erosion Con trol-Storm+Water+Calcs%281%29.pdf File size: 418660 bytes Case/Application/Permit/Entity ID: LDC-2016-00178 Entity Type: CAP Uploaded date/time: 0812512016 23:56 Last status date/time: 0812512016 23:56 Uploaded By: PUBLICUSER110285 (Id. PUBLICUSER110285) Agency/Organization: CITY OF CHARLOTTE Document name: Erosion Control -Storm Water Calcs(1).pdf Document description: Document type: LD-ACAlapplication/pol1st Submittal - Calculations This is an automated email notification. Please do not reply to this email. Mansour Edlin Consulting i;iS Mockingbird Lane Suite 802 Charlotte, NC 28209 October 10, 2015 Revised 1i.15.2016 Subject: Macleod Concrete -.4304 Northpointe Industrial Blvd. Project Description Macleod Construction proposes to build a concrete batch plant at this location. The, proposed improvements will include new entrance drive, mixing plant, aggregate storage, office trailers and related.plant improvements. Future improvements may include a maintenance shop and office. Sediment Control Erosion,&sediment control during.construction will be provided by installation and maintenance of temporary erosion control measures that are capable of achieving the required sediment trapping efficiency for the 10-year, 24-hr storm event. Erosion control measures will include stone construction entrance, silt fence and/or diversion ditches, two (2) skimmer basins, one (1)'sediment basin and.other measures as required by local jurisdiction. Storrn Water Management. Plan The total site area is T6 acres and located within a distressed business district and exempt from post construction storm water quality requirements. The site is contiguous Stewart Creek flood Plain. Portion of the site 'was cleared by the former land owner and there are no improvements Within the site. One permanent storm water detention basin is proposed to capture and attenuate runoff from the built —upon area proposed for the project. Forebay above the permanent storm pond is for pre - treating the runoff and .settling of -,solids before reaching the pond. The proposed storm water management is designed to provide s-yr, 24-hr volume control and 10-yr, 6 -hr peak control for runoff from the impervious area associated with this phase of the project. The pre and post development drainage pattern consists of three areas. Drainage area ##1 is at the front of the site drains to the street. Drainage area #2 consists of the slope and graded area below the proposed storm water pond that drains to the rear of the site. Drainage area #3 consists of four (4) sub -areas and runoff from this area is directed to the storm water pond. For the purpose of pre & post runoff calculations, and routing, these sub -areas have been combined and drainage area 43 is analyzed as one basin to the point of interest at the storm water pond. For the purpose of this analysis, drainage area #Land #2 area considered bypass area to the point of interest at the storm Water pond. Waiver Request Calculations for the 1yr, 24 hr volume control have been included. Since the site is contiguous to the regulated flood plain, the client is requesting a waiver from this requirement. LIN 6- Flour Peak.Control Drainage Area #1— Bypass 6- hour Storm Event Event Pre Post Routed Elevation Delta Post- Pre 2 Yr. 0.085 0.192 No NA o.a1(direct release) 10 Yr. 0.457 0.5a4 No o.o6 (direct release) Drainage Area #2 — Bypass 6- hours Storm Event Event Pre Post Routed Elevation Delta Post- Pre 2-Yr. 0.324 1-34 No NA 1.o (direct release) 10 Yr. 1.824 3.6o No ? .8 (direct release) Drainage Area #a — Pond Event Pre Post Routed Elevation z Yr. 0.857 15.94 0.28 721,54 10 Yr. 4-437 24.20 1.09 722.80 25 Yr: 28.95 1.65 723.48 50 Yr. 32.58 3-56 723-77 zoo Yr. �6.'16 6.27 723.99 Total Direct Release Total direct release for z year = o.11 +2..o = 1.11 cfs Total direct release for 10 year = o.o6 +1.8 = 1.86 cfs Allowable Release Rate (ARR) ARR = pre development —direct release ARR for z year Storm Event = 0.857 - 1.11 = - 0.253 cfs ARR for a.o year Storm Event = 4.437 -1:86 = 2.57 cfs Routed Release Rate from Pond 2 year Storm Event = o.28 cfs 10 year Storm Event = i.og cfs vs. 2.57 cfs Not required to control-z year Max. Allowable out of pond OK :.Yr, 24- Hour Volume Control Below is of calculations for Yolume control for drainage area #3 which constitutes the developed port of the site. 1- year, 74 hour rainfall depth = z.�8 in Drainage Area #3 — Pond Event Pre Post Routed Elevation i Yr. 0,;422 a1:71 0.207 720.89 Max. Storage per post -development hydrograph=16,885 cf Attached is calculation using spreadsheet obtained from Georgia Strom Water Manuel and using charlotte fainfall data. The required volume by this method is less than the above -method. Storage volume required=16,3io CF volume provided to invert of 6" orifice L middle of box at invert 722.0: Contour Area Inc. Storage Total Storaae lag o Sediment storage 720 8,900 sf 4,450 4,450 722 1:1,000 sf i9,900 213So 724 i2,900 sf 23,900 28,250 Volume provide (720-722): = 23,350 cf U NCDENR Na CUip — ❑[P.0 .T ov FHVIwaMM[li u D N� Ftt 0 C - 'NOTICE OF INTENT Division of Energy, Mineral and Land Resources Land Quality Section National Pollutant Discharge Elimination System NCG140000 FOR AGENCY UJ E ONLY Date Received Year Month Da Certificate of Cove he mo nth- . Permit 4s,Igtcd to rr National Pollutant Discharge Elimination System application for coverage under General Permit NCG140000: STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with activities classified as: SIC (Standard Industrial Classification) Code: 3273 and like activities - Ready Mixed Concrete This NOI may be an application to discharge process wastewater. NCG140000 contains effluent limitations for process wastewater discharges. Wastewater discharges must meet the requirements of these effluent limitations. An exceedence of any of these limitations will result in a violation of the permit conditions. For questions, please contact the DEMLR Central Office or Regional Office in your area. (See page 6} (Please print or type) 1) Mailing address of ownerloperator (official address to which all permit correspondence will be mailed): (Please print or type a# entries in this application form.) Legal Owner Name MacLeod Construction. Inc. (Please attach the most recent Annual Report to the NC Secretary of State showing the current legal name. Alternatively this permit can be given to an individual.) Signee's Name (as signed for in question 29 below) Bob MacLeod Street Address P.O. Box 320 City Denver State NC ZIP Code 28037 Telephone No. (704) 483-3680 x 2312 Email rmacamacleodconstruction.com Alternate Contact Name Sue Werth Email (if different) swerth macleodconstruction.com Alternate Contact Telephone (if different) (704) 483-3580 x 2302 2) Location of facility producing discharge: Facility Name MacLeod Construction. Inc. - North Pointe Business Park Concrete Batch Plant Facility Contact Plant Manager to be Named Street Address 4304 Northpointe Industrial Boulevard City Charlotte State NC ZIP Code 28216 County Mecklenburg Telephone No. Fax: 3) Physical location information: Please provide narrative directions to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). From 1-85140 north end of Charlotte take Exit 37 Beatties Ford Road north two blocks to North Hoskings Road and turn left: follow North Hoskings Road to Northpointe Industrial Boulevard and turn right; site is approximately'/. -mile on right hand side. (A copy of a county map or USGS quad sheet with facility clearly located on the map is a required part of this application.) — Figure 1 4) Latitude 35.280356 Longitude-80.869522 5) This NPDES Permit Application applies to the following (check all that apply): 0 New or Proposed Facility Date operation is to begin 2017 .) ❑ Existing Facility Permit # SWU-229-11032011 Page 1 of 7 Last revised 7/2/14 NCG140000 N.0.1. 6) Consultant's application information: Consultant: Mark Crammer, P.E. Consulting Firm: The El Group, Inc. (E_ I) Mailing Address: 2101 Gateway Centre Blvd., Suite 200 City: Morrisville State: NC Zip Code: 27560 Phone: (919) 459-5229 Fax: (919) 657-7551 Email: mcramer(a-)eil.com l ElMark Cramer, P.E. i i :r•rt G.u:,,.n i;,,rx nn�. sine: _��t Ere: q: amr Ei, r, rx,•,c�e: i V,., ,ills. \e: d, l�.,,�.£i=a _'i.. i ANVW,-.1com 7) Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility: SIC Code: 3273 8) Provide a brief description of the types of industrial activities and products produced at this facility: (Attach a site diagram showing the process areas present at this facility.) — Figure 2 Central Mix Concrete Plant Stormwater Discharge, Wastewater Treatment & Discharge and Permitting Information 9) Discharge points / Receiving waters: Number of discharge points (ditches, pipes, channels, etc.) that convey stormwater and/or wastewater from the property: Stormwater-only: Wastewater -only: Wastewater Commingled with Stormwater: 1 For new facilities: Expected date of commencement of discharge: 2017 What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater and/or wastewater discharges end up in? Stewart Creek Receiving water classifcation(s), if known: C If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). Will this facility discharge wastewater to SA (Shellfishing) waters? ❑ Yes ❑x No Note: Discharge of process wastewater to receiving waters classified as WS-II to WS-V or SA must be approved by the N.C. Division of Water Resources, Public Water Supply Section. If DWR does not approve, coverage under NCG140000 cannot be granted. No new discharges of process wastewater are permitted in receiving waters classified as WS-1 or freshwater ORW. 10) Each applicant shall provide the following information (attach additional sheets as necessary): 11) Two (2) site plans depicting the facility or site with numbered outfalls which indicate stormwater and wastewater outfalls. The plans shall legibly show. at a minimum, (existing or proposed): — Figure 2 o Outline of drainage areas with topographical lines and features o Stormwatedwastewater treatment structures o Location of numbered stormwater/wastewater outfa[Is (corresponding to which drainage areas) o Runoff conveyance structures o Areas and acreage where materials are stored o Impervious area acreages o Location(s) of streams and/or wetlands the site is draining to, and any applicable buffers o Site property lines, North Arrow, and bar scale o . If applicable, the 100-year floodplain line Page 2 of 7 SWU-229-07122011 Last revised 712114 NCG140000 N.O.I. C U o Acreage of each stormwater and wastewater topographical area o Each of the facilities' wastewater or stormwater source and discharge structures and each of its hazardous waste treatment, storage, or disposal facilities o Site location (insert) Site plans shall be 24"x 36" in size. • Line drawing and description: A line drawing of the water flow through the facility. A pictorial description of the nature and amount of any sources of water and any collection and treatment measures. • A narrative description and identification of each type of process, operation, or production area which contributes wastewater to the effluent for each outfall, and a description of the treatment the wastewater receives (or will receive), including the ultimate disposal of any solid or fluid wastes other than by discharge. Processes, operations, or production areas may be described in general terms (e.g. "ash silo"). — One outfall for Batch Concrete Plant. 12) Does the applicant have any unresolved Notice of Violations (NOVs)? ❑x No ❑ Yes Wastewater., 13) What types of wastewater does your facility generate or discharge? Type of Authori ed.Wastewater Generate Discharge : K Sent #o WW", ' System. ' Vehicle and equipment cleaning VE ❑x 0 ❑ Wetting of raw material stockpiles (RM) 0 ❑ Mixing drum cleaning MD x ❑ Further explanation, if necessary: 14) Will your facility spray -down or actively wet aggregate piles? ❑ No ❑X Yes 15) Does the facility use any of the following on site? ❑ Phosphorus -containing Detergents ❑ Non -Phosphorus -containing Detergents ❑ Brighteners ❑X Other Cleaning Agents — SDSs. Attached ❑ Other: 16) Are wastewater treatment facilities planned in the 100-year flood plain? ❑x No ❑ Yes 17) Does your facility use or plan to use a recycle system, or recycle components in your treatment system? IR Yes ❑ No If yes, what size storm event is the system designed to hold before overflowing? (for example, 10-yr, 24-hr) 1-year, 24-hour rainfall event volume and 10- ear 6-hour rainfall event volume SWU-229-07122011 Page 3 of 7 Last revised 712114 NCG140000 N.4.1. 18) Will your facility build a closed -loop recycle system that meets design requirements in 15A NCAC 02T .1000 and hold your facilities' working volume'? i ❑ Yes ❑X No Will your facility discharge wastewater to surface waters? ❑X Yes ❑ No If the facility's treatment system meets the design requirements of 15A NCACO2T .1000 (including holding the 25-year, 24-hour storm plus one foot of freeboard), holds the working volume of your site, and does not discharge wastewater to surface waters, you may not be required to obtain an NPDES permit for wastewater discharges. if you believe this is the case, please contact DEMLR's Aquifer Protection Section Land Application Unit Central Once Supervisor or staff (1636 Mail Service Center, Raleigh, NC 27699-1636) for more information on obtaining the necessary permits or approvals. if you will discharge wastewater or stormwater to surface waters, please continue to apply for a permit to discharge associated with ready -mixed concrete or like operations under NCG140000. For further questions, please contact DEMLR's Stormwater Permitting Unit Staff. 19) A wastewater treatment alternatives review is required by 15A NCAC 2H.0105 (c)(2) for any new or expanding water pollution control facility's discharge in North Carolina. You may attach additional sheets. a) What wastewaters were considered for this alternatives review? ❑X VE X❑ RM ❑X MD b) Connection to a Municipal or Regional Sewer Collection System: Are there existing sewer lines within a one -mile radius? ..................................... ❑X Yes ❑ No (1) If Yes, will the wastewater treatment plant (WWTP) accept the wastewater? .... ❑ Yes X❑ No See attached e-mail from Doug Wise of Charlotte Water dated October 16, 2015. (a) If No, please attach a letter documenting that the WWTP will not accept the wastewater. . (b) If Yes, is it feasible to connect to the WWTP? Why or why not?` c) Closed -loop Recycle System (must meet design requirements of 15A NCAC 2T .1000): i) Are you already proposing a closed -loop recycle system (CLRS)? ❑ Yes 0 No (1) If Yes, contact DEMLR's Aquifer Protection Section's Land Application Unit (2) If No, is this option technologically feasible (possible)? Why or why not?*Available land does not provide sufficient storage capacity.- _- (3) If No, is it feasible to build a CLRS on your site? Why or why not?* Available land does not provide sufficient storage capacity. _ (4) What is the feasibility of building a CLRS compared to direct surface water discharge?* economically not feasible, and sufficient land not available for required storage capacity. Retaining drainage from entire site would also significantly reduce recharge to Stewarts Creek. d) Surface or Subsurface Disposal System (e.g., spray irrigation): i) Is a surface or subsurface disposal technologically feasible (possible)? .....................❑ Yes 0 No Why or Why not? Land restricted. ii) Is a surface or subsurface disposal system feasible to implement?* ......... .................. ❑ Yes No Why or Why not? Land restricted. 1 See DWQ's Aquifer Protection Section Land Application Unit's Water Balance Calculation Policy for more information, on DWQ LAU's websitehttp:t/i)ortal.ncdenr.org/webtwq/apsAau/policies for more information. Page 4 of 7 SWU-229-07122011 Last revised 712114 NCG140000 N.O.I. iii) What is the feasibility of employing a subsurface or surface discharge as compared to a direct discharge to surface waters?* Land restricted. e) Direct Discharge to Surface Waters: Is discharge to surface waters the most environmentally sound alternative of all reasonably cost-effective options of the wastewaters being considered?*... 0 Yes ❑ No i) if No, contact DEMLR's Land Application Unit to determine permitting requirements. f) If this review included all wastewater discharge types, would excluding some types (e.g. raw stockpile wetting) make any of the above non -discharge options feasible? ..............❑ Yes 0 No * You may be asked to provide further information to support your answers to these questions after the initial review. Feasibility should take into account initial and recurring costs. Stormwater: 20) Does this facility employ any best management practices for Stormwater control? ❑ No 0 Yes If yes, please briefly describe: Retention pond and settling system standard for batch concrete plants. 21) Does this facility have a Stormwater Pollution Prevention Plan? 0 No ❑ Yes If yes, when was it implemented? SWPPP under development at time of development of this Notice of Intent (NOO for coverage under NCG140000, prior to construction__SWPPP will be finalized and implemented upon startup of operation. 22) Are vehicle maintenance activities (VMA) occurring or planned at this facility? ❑ No 0 Yes If yes, does your VMA area discharge into your wastewater treatment device? ❑ No 0 Yes Other/Permitting: 23) Does this facility have a Division of Land Resources Erosion & Sedimentation Control (E&SC) Permit? 0 No ❑ Yes If yes, list the permit numbers for all current E&SC permits for this facility: Applied for and permit is pending from City of Charlotte. See attached City of Charlotte e-mail receipt. 24) Is your facility subject to Phase Il Post -Construction Area? 0 Yes ❑ No If yes, who is the permitting authority? City of Charlotte is„within Phase II Post -Construction Area: however, distressed business district exempt from certain post construction stormwater ordinance requirements. See Post -Construction Control Ordinance PCCO Summary in attached Figure 2 25) Is your facility located in one of the 20 Coastal Counties? ❑ Yes 0 No Is your facility adding more than 10,000 ft2 of built -upon area or CAMA Major Permit? ❑ Yes ❑ No 26) Is your facility discharging wastewater (treated or untreated) such as water from wetting of aggregate piles, drum rinse -out, or vehicle and equipment cleaning to a stormwater BMP7 ❑ No Yes If yes, please attach your approval from the permitting authority to do so. — DEQ is the permitting- authority. 27) Does this facility have any other NPDES permits? 0 No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: 28) Does this facility have any Non -Discharge permits (ex: recycle permits)? 0 No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 29) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? Page 5of7 SWU-229-07122011 Last revised 7i2114 NCG140000 N.O.I. No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? ❑X No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? ❑x No ❑ Yes d) Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor: Vendor address: Final Checklist This application will be returned as incomplete unless all of the following items have been included: ❑X Check for $100 made payable to NCDENR. This completed application and all supporting documentation. See Question 10, X❑ If an Erosion & Sedimentation Control (E&SC) Plan is required from Division of Land Resources (DLR) or local designee: documentation verifying applicant has developed and submitted that Plan to the governing agency (required per 15A NCAC 02H .0138). — Applied for -and permit is pending from City of Charlotte. See attached City of Charlotte e-mail receipt. 1 ❑x Two (2) site plans depicting the site plan with numbered outfalls which indicate stormwater and wastewater outfalls. See Question 10 — Figure 2 0 A county map or USGS quad sheet with location of facility clearly marked. — Figure 1 30) Signatory Requirements (per 40 CFR 122.22) All applications, reports, or information submitted to the Director shall be signed and certified. a. All notices of intent to be covered under this General Permit shall be signed as follows: (1) For a corporation: by a responsible corporate officer. For the purpose of this permit, a responsible corporate officer means: (a) a president, secretary, treasurer or vice president of the corporation in charge of a principal business function, or any other person who performs similar policy or decision making functions for the corporation, or (b) the manager of one or more manufacturing production or operating facilities employing more than 250 persons or having gross annual sales or expenditures exceeding 25 million (in second quarter 1980 dollars), if authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures. (2) For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or (3) For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. Page 6 of 7 SWU-229-07122011 Last revised 7/2/14 '�-j NCG140000 N.O.I. Certification: North Carolina General Statute 143-216.6 B(I) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Articl% or who knowingly makes a false statement of a material fad In a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with. or knowingty, renders inaccurate arty recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Bob MacLeod Title: President L Z (Sign re of Applicant) (Date Signed) Notice of Intent must be accompanied by a check or money order for $100.00 made payable to: NCDENR Mail the entire package to: Stormwater Permitting Unit Program Division of Energy, Mineral and Land Resources 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee the Issuance of an NPDES permit. For questions, please contact the DEMLR Regional Office for your area. DEMLR Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office... (910) 433-3300 Mooresville Office... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ... (252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office ......... (919) 807-6300 Page 7 of 7 SM-229-07122011 Last reNsed 712I14 THE El GROUP, INC. ... Wel_I5 Far' 'N A. 2101 GATEWAY CENTRE BOULEVARD _ SUITE 200 66-162.531 MORRISVILLE, NC 27560 CHECK DATE 12/14/2016 PAY ..One Hundred and 001100 Doflars .. — AMOUNT N TO_ ` _ 100.00 NC DENR Stormwater Permitting Unit Program s w Division of Enefgy,.Minerai & Land Resources - 1612µMali Service Center - _-.Raleigh, NC 27699 1612 _, -" a 1HO 1)StONATURE r GHS Safety Data Sheet ��� CHEM-TECH SOLUTIONS CHEM-TECH SOLUTIONS, INC WESTECH CT-2400 "COMPLETE" TRUCK WASH MSDS Number: 10OB-4743 Revision Date: 10/23/2013 Page 1 of 5 1 1 PRODUCT AND COMPANY IDENTIFICATION Manufacturer CHEM-TECH SOLUTIONS, INC 427 BROOK ST. BELMONT, NC 28012 Contact: Corporate Safety Compliance Phone: 704-829-9202 Fax: 704-829-9203 Email: info@chemtechsotutions.com www.chemtechsolut ons.com Web: Product Name: WESTECH CT-2400 'COMPLETE' TRUCK WASH Revision Date: 1012312013 MSDS Number: 100E-4743 4743 Product Code: Industrial Cleaning Agent Product Use: EMERGENCY TELEPHONE: EMERGENCY 24 HOUR SERVICE CHEM-TEL, INC. 1-800-255-3924 2 J HAZARDS IDENTIFICATION Route of Entry: Dermal contact, Eye contact, Ingestion Target Organs; Inhalation: Skin Contact: Eye Contact: Ingestion: N FPA: HMIS III: AFIRE HA:ZARO' i 1 � L \ 1 Skin; Eyes If misted can cause irritation and inflammation of the respiratory tract. Primary exposure route, irritant to the skin with prolonged contact. Irritation and will cause burns if not treated immediately May cause burns of mouth, esophagus, throat and stomach. Health = 1, Fire = 0, Reactivity = 0 H1/F0/PH0 HMIS III Comm [�'l�i m 0 PERSONAL PROTECTION B I Safety Glasses, Gloves sas lmff+mo+ sae+ MW +V Msas+ J+' M+ ®Q+rr+i+ : 8 M+ 00+ram © AL� +-'+IL 41!G + .e + ++4F w� sar.ro+xeeeae- n.,a AM a �r P m*q Qr i-s•R t 4 u w y� GHS Safety Data Sheet per; C HST CHEM-TECH SOLUTIONS, INC WESTECH CT-2400 "COMPLETE" TRUCK WASH MSDS Number: 10OB-4743 Revision Date: 10/23/2013 Page 2 of 5 GHS Signal Word: WARNING GHS Hazard Pictograms: < I > GHS Classifications: Health, Acute toxicity, 4 Oral Health, Skin corrosion/irritation, 3 Health, Serious Eye Damage/Eye Irritation, 2 B GHS Phrases: H302 - Harmful if swallowed H316 - Causes mild skin irritation H320 - Causes eye irritation GHS Precautionary Statements: Keep out of reach of children. Read label before use. Do not handle until all safety precautions have been read and understood. Keep container tightly closed. Wash _ thoroughly after handling. IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician. IF ON SKIN: Flush with cool water for 15 minutes. IF IN EYES: Rinse continuously with water for 151 minutes. Remove contact lenses if present and easy to do. Continue rinsing. Do NOT induce vomiting. 3 COMPOSITIONIINFORMATION ON INGREDIENTS Ingredients: Trade Secret Trade Secret status: For emergency situations additional product information may be obtained by calling the "Emergency 24 Hour Service" number listed in section 1. Reference 29 CFR 1910.1200 andlor 40 CFR 350 4 1 FIRST AID MEASURES Inhalation: Remove victim from contaminated area and get fresh air. Seek immediate medical attention if artificial respiration is required. Skin Contact: Flush with cool water for 15 minutes. If irritation persist, see doctor. Eye Contact: Immediately flush eyes with large amounts of water for at least 15 minutes, lifting eyelids occasionally to facilitate irrigation. If irritation persist seek immediate medical attention. Ingestion: Do not induce vomiting. Immediately give two to four glasses of milk. Never give anything by mouth to an unconscious person. Seek medical attention immediately. GHS Safety Data Sheet pai 'JCHEM-TECH SOLUTIONS CHEM-TECH SOLUTIONS, INC <.b�,_ WESTECH CT-2400 "COMPLETE" TRUCK WASH MSDS Number: 10OB-4743 Revision Date: 10/2312013 Pago 3 of 5 5 FIRE FIGHTING MEASURES Flash Point: Product is water based and will not support flames. Extinguisher Media: Use water spray, foam, dry chemical or other agents suitable for surrounding fire. Special Fire Fighting Wear NioshIMSHA approved self-contained breathing apparatus and Procedures: full protective clothing. Unusual Fire and Hydrogen could be generated by the action of this solution on some metals. Explosion Hazard: S 1 ACCIDENTAL RELEASE MEASURES For small spills, use sand or other absorbent material to absorb product. Place into a container for later disposal. For large spill, stop at source then dike to prevent spreading. Transfer to salvage tank or suitable container. Discharge into public waters, retention ponds, streams or lakes is not permitted. Reference SARA Title III, 40 CFR 372 for reporting requirements. 7 1 HANDLING AND STORAGE Handling Precautions: Handlo with care and avoid spillage on the floor ( slippage). Keep away from sources of ignition. Care must be taken when using or disposing of the Chemical materials and/or their containers to prevent environmental contamination. Storage Requirements: Since empty containers may retain product residues (vapor, liquid or solid) all labeled precautions must be observed. For industrial use only. Keep out of reach of children. $ 1 EXPOSURE CONTROLS/PERSONAL PROTECTION Engineering Controls: All ventilation should be designed in accordance with OSHA standard (29 CFR 1910.94), Personal Protective Equip: HMIS PP,13 i Safety Glasses, Chemical resistant gloves: Ventilation: Local Exhaust is preferred to keep below exposure threshold if product is utilized in enclosed area. 9 1 PHYSICAL AND CHEMICAL PROPERTIES Appearance: Amber Physical State: Liquid Odor: Mild chemical odor Spec Gray.IDensity: 1.26 Solubility: Complete Viscosity: 85 (Brookfield LV @ 70 F (cps)) FreezinglMelting Pt.: 32 F (0 C) Boiling Point: 212 F (100 C) Flash Point: Non Flammable pH: 1.1 VOC: NE ul7S Safety Data Sheet CHEM-TECH SOLUTIONS CHEM-TECH SOLUTIONS, INC a n WESTECH CT-2400 "COMPLETE" TRUCK WASH MSDS Number: 10OB-4743 Revision Date: 10/23/2013 Page 4 of 5 10 STABILITY AND REACTIVITY Stability: Stable Conditions to Avoid: Freezing and Boiling Materials to Avoid: Acids, Alkalines, or Oxidizers Hazardous Decomposition: Decomposition will not occur Hazardous Polymerization: will not occur. 11 1 TOXICOLOGICAL INFORMATION Toxicity Data: Trade Secret 12 ECOLOGICAL INFORMATION Readily biodegradable. Material is not expected to produce any significant environmental effects when recommended use instructions are followed. 13 DISPOSAL CONSIDERATIONS Must be in accordance with Federal. State and Local Laws regulating such materials. 14 1 TRANSPORT INFORMATION Not a hazardous product according to these transport classifications. U.S. Department of Transportation (DOT) Proper Shipping Name: Not Regulated Hazard Class: Not Regulated •UN/NA Number: done Packing Group: None Labels Required: None Required Product is manufactured in compliance with the Department of Transportation as cited in 49 CFR 173.154 GHS Safety Data Sheet � p,7 CHEM-TECH SOLUTIONS `nrowm�eotmv b,a+swwgt�Wr_ CHEM-TECH SOLUTIONS, INC WESTECH CT-2400 "COMPLETE" TRUCK WASH MSDS Number: 10OB-4743 Revision Date: 10/23/2013 Page 5 of 5 15 REGULATORY INFORMATION U.S. Federal Regulations: Toxic Substances Control Act (TSCA): All ingredients are either listed on the TSCA inventory or are exempt. Comprehensive Environmental Response, Compensation and liability Act (CERCLA): None Superfund Amendments Reauthorization Act (SARA) Title III: Section 302 Extremely Hazardous Substances (EHS): None Section 311/312 Hazard Categories: Fire Hazard: No Reactive Hazard: No Release of Pressure: No Acute Health Hazard: No Chronic Health Hazard : No Section 313 Toxic Chemicals: This product contains the following substances subject to the reporting requirements of Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 and 40 CFR Part 372: None Clean Air Act: Section 112 Hazardous Air Pollutants (HAPs): None California Safe Drinking Water and Toxic Enforcement Act (Prop 65): This product may contain the following chemicals know to the state of California to cause cancer, birth defects or other reproductive harm: None 16 1 OTHER INFORMATION This document is prepared in accordance with 29 CFR 1910.1200 requirements. The information provided in this Safety Data Sheet is based on data obtained from component manufacturer, industry professionals and technical reference material. Specific data regarding toxicological information is directly from published manufacturer requirements. While the information is believed to be true and accurate to the best of our knowledge, the author makes no representations as to its sufficiency. Seller makes no warranty, whether expressed or implied including warranties of merchantability of fitness for a particular purpose. Buyer accepts liability for determining if the product is suitable for buyer's intended use and resale. Any recommendations as to use made by seller is done so at buyer's risk. Buyer's exclusive remedy and seller's liability for damages shall never exceed purchase price or replacement of product. GHSSafety Data Sheet per; CHEM-TECH€ SOLUTIONS CHEM-TECH SOLUTIONS, INC WESTECH CT-3500 "BLASTER" MSDS Number: 100E-4740 Revision Date: 10/16/2013 Page t of 5 1 PRODUCT AND COMPANY IDENTIFICATION Manufacturer CHEM-TECH SOLUTIONS, INC 427 BROOK ST. BELMONT, NC 28012 Contact: Corporate Safety Compliance Phone: 704-829-9202 Fax: 704-829-9203 Email; info@chemtechsolutions.com www.chemtechsolutions.com Web: Product Name: WESTECH CT-3500 "BLASTER" Revision Date: 1011612013 MSDS Number: IOOB-4740 Product Code: 4740 Industrial Cleaning Agent Product Use: EMERGENCY TELEPHONE: EMERGENCY 24 HOUR SERVICE CHEM-TEL, INC. 1-800-255-3924 2I HAZARDS IDENTIFICATION Route of Entry: Target Organs: Inhalation: Skin Contact: Eye Contact: Ingestion: N FPA: HMIS III: NFPA kNn.1 j Dermal contact. Eye contact, Ingestion Skin; Eyes Irritation of the respiratory passages with cough, difficulty in breathing and bronchial irritation. Primary exposure route, irritant to the skin with prolonged contact. Irritation and will cause bums if not treated immediately May cause bums of mouth, exophagus, throat and stomach. R E A C T, fl } V, I, Y, Health = 1, Fire = 0, Reactivity = 0 H1IF0/PH0 HMIS III ❑ 1 ZZIN" wiasmI no PERSONAL PROiECT10N B 1 Safety Glasses, Gloves �ee+•ro p:v+-&+A pQ+mft+r+* +�+o © +E*+�+� Y cwrn rw w.aa.aH n ° -r p IL r s rr z �> s Safety Data Sheet p .C. � SOLUTIONS CHEM-TECH SOLUTIONS, INC WESTECH CT-3500 "BLASTER" MSDS Number: 100E-4740 Revision Date: 10/16/2013 Page 2 of 5 GHS Signal Word: WARNING GHS Hazard Pictograms: 1 A GHS Classifications: Health, Skin corrosion/irritation, 3 Health, Acute toxicity, 4 Oral Health, Serious Eye Damage/Eye Irritation, 2 8 GHS Phrases: H316 - Causes mild skin irritation H302 - Harmful if swallowed H320 - Causes eye irritation GHS Precautionary Statements: Keep out of reach of children. Read label before use. Do not handle until all safety precautions have been read and understood. Keep container tightly closed. Wash _ thoroughly after handling. IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician. IF ON SKIN: Wash with soap and water. IF IN EYES: Rinse continuously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. 3 1 COMPOSITION/INFORMATION ON INGREDIENTS Ingredients: Trade Secret Trade Secret status: For emergency situations additional product information may be obtained by calling the "Emergency 24 Hour service" number listed in section 1. Reference 29 CFR 1910.1200 and/or 40 CFR 350 4 1 FIRST AID MEASURES Inhalation: Remove victim from contaminated area and get fresh air. Seek immediate medical attention if artificial respiration is required. Skin Contact: Flush with cool water for 15 minutes. If irritation persist, see doctor. Eye Contact: Immediately flush eyes with large amounts of water for at least 15 minutes, lifting eyelids occasionally to facilitate irrigation. If irritation persist seek immediate medical attention. Ingestion: Do not induce vomiting. immediately give two glasses of water. Never give anything by mouth to an unconscious person. Seek medical attention immediately. Safety Data Sheet p '7 CHEM-TECH SOLUTIONS GHS CHEM-TECH SOLUTIONS, INC WESTECH CT-3500 "BLASTER" MSDS Number: 100E-4740 Revision Date: 10/16/2013 Page 3 of S 5 FIRE FIGHTING MEASURES Flash Point: Product is water based and will not support flames. Extinguisher Media: Use water spray, foam, dry chemical or other agents suitable for surrounding fire. Special Fire Fighting Wear Niosh/MSHA approved self-contained breathing apparatus and Procedures: full protective clothing. Unusual Fire and Hydrogen could be generated by the action of this solution on some metals. Explosion Hazard: 6 1 ACCIDENTAL RELEASE MEASURES For small spills, use sand or other absorbent material to absorb product. Place into a container for later disposal. For large spill, stop at source then dike to prevent spreading. Transfer to salvage tank or suitable container. Discharge into public waters, retention ponds, streams or lakes is not permitted. Reference SARA Title III, 40 CFR 372 for reporting requirements. 7 1 HANDLING AND STORAGE Handling Precautions: Handle with care and avoid spillage on the floor( slippage). Keep away from sources of ignition. Care must be taken when using or disposing of the Chemical materials and/or their containers to prevent environmental contamination. Storage Requirements: Since empty containers may retain product residues (vapor, liquid or solid) all labeled precautions must be observed. For industrial use only. 8 I EXPOSURE CONTROLSIPERSONAL PROTECTION Engineering Controls: All ventilation should be designed in accordance with OSHA standard (29 CFR 1910.94). Personal Protective Equip: HMIS PP, B I Safety Glasses, Chemical Resistant Gloves Ventilation: Local Exhaust is preferred to keep below exposure threshold if product is utilized in enclosed area. 9I PHYSICAL AND CHEMICAL PROPERTIES Appearance: Amber Physical State: Liquid Odor: Faint Orange Odor Spec Gray./Density: 1,084 Solubility: Complete Viscosity: 88 (Brookfield LV @70F(cps)) Freezing/Melting Pt.: 32 F (0 C) Boiling Point: 212 F (100 C) Flash Point: Non Flammable 1.97 > 1, (Water= 1) VOC: NE Evap. Rate: GHSSafety Data Sheet y ; C, E -TEC SOLUTIONS CHEM-TECH SOLUTIONS, INC WESTECH CT-3500 "BLASTER" MSDS Number: 100B-4740 Revision Date: 10/16/2013 Page 4 of 5 10 STABILITY AND REACTIVITY Stability: Stable Conditions to Avoid: Freezing and Boiling Materials to Avoid: Strong Oxidizing Agents, Alkalines or Active Metals Hazardous Decomposition: Decomposition will not occur Hazardous Polymerization: Will not occur 11 1 TOXICOLOGICAL INFORMATION Toxicity Data: Trade Secret 12 1 ECOLOGICAL INFORMATION Readily biodegradable. Material is not expected to produce any significant environmental effects when recommended use instructions are followed. 13 DISPOSAL CONSIDERATIONS Must be in accordance with Federal, State and Local Laws regulating such materials. 14 TRANSPORT INFORMATION Not a hazardous product according to these transport classifications. U.S. Department of Transportation (DOT) Proper Shipping Name: Not Regulated Hazard Class: Not Regulated UN/NA Number: None Packing Group: None Labels Required: None Required Product is manufactured in compliance with the Department of Transportation as cited in 49 CFR 173.154 GHS Safety Data Sheet C CHEM-TECH SOLUTIONS � YMY,-aV.mabYa�R- CHEM-TECH SOLUTIONS, INC WESTECH CT-3500 "BLASTER" MSDS Number: 100E-4740 Revision Date: 10/16/2013 Page 5 of 5 1.15 REGULATORY INFORMATION U.S. Federal Regulations: Toxic Substances Control Act (TSCA): All ingredients are either listed on the TSCA inventory or are exempt. Comprehensive Environmental Response, Compensation and Liability Act (CERCLA): None Superfund Amendments Reauthorization Act (SARA) Title III: Section 302 Extremely Hazardous Substances (EHS): None Section 3111312 Hazard Categories: Fire Hazard: No Reactive Hazard: No Release of Pressure: No Acute Health Hazard:' No Chronic Health Hazard : No Section 313 Toxic Chemicals: This product contains the following substances subject to the reporting requirements of Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 and 40 CFR Part 372: None Clean Air Act: Section 112 Hazardous Air Pollutants (HAPs): None California Safe Drinking Water and Toxic Enforcement Act (Prop 65): This product may contain the following chemicals know to the state of California to cause cancer, birth defects or other reproductive harm: None 16 OTHER INFORMATION This document is prepared in accordance with 29 CFR 1910.1200 requirements. The information provided in this Safety Data Sheet is based on data obtained from component manufacturer, industry professionals and technical reference material. Specific data regarding toxicological information is directly from published manufacturer requirements. While the information is believed to be true and accurate to the best of our knowledge, the author makes no representations as to its sufficiency. Seller makes no warranty, whether expressed or implied including warranties of merchantability of fitness for a particular purpose. Buyer accepts liability for determining if the product is suitable for buyer's intended use and resale. Any recommendations as to use made by seller is done so at buyer's risk. Buyer's exclusive remedy and seller's liability for damages shall never exceed purchase price or replacement of product.