WITHERS & RAVENEL
ENGINEERS I PLANNERS I SURVEYORS
115 MacKenan Drive
CARY, NORTH CAROLINA, 27511
(919) 469-3340
FAX (919) 467-6008
TO: NCDENR
512 N. Sal isbury St.
Archdale Building, 91h Floor
Raleigh, NC 27604
WE ARE SENDING YOU ® Attached via
❑ Shop Drawings ® Prints
❑ Copy of Letter ❑ Change order
LETMIR ®F URAHMUUAL
DATE 11 /20/2013
1 JOB No. 2120170.00
ATTENTION Bethany Georgoul ias
PHONE # (919) 807-6372
RE: Eagle Rock — Pristine Water Drive
Closed Loop Recycle System As-Builts
the following items:
® Plans ❑ Samples ❑ Specifications
❑ Diskette ❑
COPIES
DATE
NO.
DESCRIPTION
2
11/19/13
Closed Loop Wastewater Recycle System As -Built Plans
THESE ARE TRANSMITTED as checked below:
❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval
® For your use ❑ Approved as noted ❑ Submit copies for distribution
® As requested ❑ Returned for corrections ❑ Return corrected prints
❑ For review and comrrient ❑
❑ FOR BIDS DUE 20 ❑ PRINTS RETURNED AFTER LOAN TO US
REMARKS: Bethany,
Please find the attached as -built plans for the State's records. D ,52P,inMrr�
Thank you. f ! NOV 2 1 2011 j !
COPY TO: Adam Loftin, Eagle Rock; File SIGNED: R
If enclosures are not as noted, kindly notify us at once.
er, PE
Geor oulla5,. Bethany
From: Georgoulias, Bethany
Sent: Wednesday, July 31, 2013 2:30 PM
To: 'Werenko, Dale'
Cc: 'Dexter Tart'; 'Fisher, Ryan'; Bennett, Bradley; Risgaard, Jon; Smith, Danny;
'adam@eaglerockconcrete.com'
Subject: RE: Eagle Rock Concrete, LLC - Pristine Water Drive Site
Attachments: NCG140427_C0C_corrected.pdf
Dale,
Please see the attached corrected Certificate of Coverage (COC) for NCG140427, Eagle Rock Concrete's Pristine Water
Drive site in Apex.I will mail a hard copy with the signature to Mr. Adam Loftin today, and I will send another signed
copy down to DWQ's Central Files. Because it is a correction, I have kept the original effective date.
The COC now includes only stormwater discharge and does not cover any wastewater discharges from this site. This
condition reflects the information presented in Eagle Concrete, LLC's N01 application. Groundwater standards in 15A
NCAC 02L and 02T regulations must also be met for recycle systems or any discharges to groundwater.
If you have any other questions or concerns, please let me know.
Thanks,
Bethany
Bethany Georgoulias
Environmental Engineer
NCDENR I DWQ I Stormwater Permitting Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
512 N. Salisbury St, Raleigh, NC 27604
Phone: (919) 807-6372
Fax: (919) 807-6494
NEW Website: http://portal.ncdenr,org/web/wq/ws/su
E-mail correspondence to and from this address may be subject to the North Carolina Public
Records Law and may be disclosed to third parties.
From: Georgoulias, Bethany
Sent: Wednesday, July 31, 2013 1:48 PM
To: 'Werenko, Dale'
Cc: Dexter Tart; Fisher, Ryan; Bennett, Bradley
Subject: RE: Eagle Rock Concrete, LLC - Pristine Water Drive Site
Hi Dale,
I'd included the process wastewater discharge on the COC because you all decided not to pursue the closed -loop recycle
system permit through APS. However, we can make the correction and include only stormwater on the NPDES permit.
This will mean that any process wastewaters that discharge, even if rarely, would be unauthorized. We recognize that's
an unlikely scenario because the system was designed to contain all wastewaters and the 25-year, 24-hour event. I will
be glad to correct the COC so it is consistent with the original application and with the other plant's COC.
I will do my best to send that correction in the next couple of days. I am working on our transition to a new Division and
electronic renewals for NCG21 the rest'of the week and will be on vacation all next week. If you don't hear from me
before then, I'll get to this as soon as I return.
Regards,
Bethany Georgoulias
Environmental Engineer
NCDENR I DWQ I Stormwater Permitting Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
512 N. Salisbury St, Raleigh, NC 27604
Phone: (919) 807-6372
Fax: (919) 807-6494
NEW Website: http://Portal.ncdenr,org/web/wg/ws/su
E-mail correspondence to and from this address may be subject to the North Carolina Public
Records Law and may be disclosed to third parties.
From: Werenko, Dale [mailto:DWerenko@withersravenel.com]
Sent: Wednesday, July 31, 2013 8:26 AM
To: Georgoulias, Bethany
Cc: Dexter Tart; Fisher, Ryan
Subject: RE: Eagle Rock Concrete, LLC - Pristine Water Drive Site
Bethany,
To follow up my voicemail, please see the attached NCG14 permit issued for the Mt. Herman Road site. Both sites have
been designed in the same manner— separating stormwater from wastewater and storing/capturing all of the
wastewater from a 24 hr-25 yr storm event (per 15A NCAC 02L and 02T regulations) without discharging. So there is no
wastewater discharge to test, only stormwater discharge.
Please let us know what we need to do to reconcile the permits so they are in agreement.
Thanks,
Dale Werenko, PE, CFM
WITHERS &- RAVENEL
919.535.5171 (o) i 919.609.9334 (c)
From: Georgoulias, Bethany [maiIto: bethany.georgouliasOncdenr.goov]
Sent: Friday, July 26, 2013 10:50 AM
To: Werenko, Dale
Cc: Fisher, Ryan
Subject: RE: Eagle Rock Concrete, LLC - Pristine Water Drive Site
Dale and Ryan,
Attached is the issuance letter and Certificate of Coverage (COC) that will be going out today.
Regards,
Bethany Georgoulias
Environmental Engineer
NCDENR I DWQ I Stormwater Permitting Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
512 N. Salisbury St, Raleigh, NC 27604
F
J
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF WATER QUALITY
GENERAL PERMIT NO. NCG140000
CERTIFICATE OF COVERAGE No. NCG140427
STORMWATER AND WASTEWATER DISCHARGES
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
In compliance with the provision of North Carolina General Statute 143-215.1, other lawful
standards and regulations promulgated and adopted by the North Carolina Environmental
Management Commission, and the Federal Water Pollution Control Act, as amended,
Eagle Rock Concrete, LLC
is hereby authorized to discharge stormwater from a facility located at
Eagle Rock Concrete - Pristine Water Drive
500 Pristine Water Drive
Apex
Wake County
to receiving waters designated as an unnamed tributary (UT) to Middle Creek, a class
QNSW water in the Neuse River Basin, in accordance with the effluent limitations,
monitoring requirements, and other conditions set forth in Parts 1, 11, I11, IV, Vl, VII, and VIII
of General Permit No. NCG140000 as attached.
This certificate of coverage shall become effective July 26, 2013.
This Certificate of Coverage shall remain in effect for the duration of the General Permit.
Signed this day July 26, 2013
for Thomas A. Reed6r, Acting Director
Division of Water Quality
By the Authority of the Environmental Management Commission
ME
AL
A,
WDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Pat McCrory Thomas A. Reeder
Governor Acting Director
July 26, 2013
Mr. Adam Loftin
Eagle Rock Concrete, LLC
8310 Bandford Way
Raleigh, NC 27615
John Skvarla, ill
Secretary
Subject: General Permit No. NCG140000
Eagle Rock Concrete, LLC - Pristine
Water Drive Plant
COC No. NCG140427
Wake County
Dear Mr. Loftin:
In accordance with your application for a discharge permit received on April 26,
2013, we are forwarding herewith the subject certificate of coverage (COC) to discharge
under the subject state - NPDES general permit. This permit is issued pursuant to the
requirements of North Carolina General Statute 143-215.1 and the Memorandum of
Agreement between North Carolina and the US Environmental Protection Agency dated
October 15, 2007 (or as subsequently amended).
Please note that NCG140000 contains effluent limitations for process wastewater
discharges (see Part IV, Section D), in addition to stormwater discharge requirements.
Wastewater discharges must comply with these effluent limitations. Your application
indicated that a closed -loop recycle system will be used to recycle all process wastewaters
at this site. Any discharges as a result of overflows are subject to the terms of this NPDES
discharge permit. Also, recycle systems and any discharges to groundwater must meet the
groundwater standards in 15A NCAC 02L and 02T regulations.
Wetlands and 5tormwater Branch
1617 Mail Service Center, Raleigh, North Carolina 27699-1617
Location: 512 N. Salisbury St. Raleigh, North Carolina 27604
Phone: 919-807-53001 FAX: 919-807-64941 Customer Service: 1-877-623-6748
Internet: www.ncwaterquality.org
An Equal Opportunity 1 Affirmalive Action Employer
Nne
orthCarolina
Naturldy
A. Loftin, Eagle Rock Concrete, LLC
July 26, 2013
Page 2 of 2
This certificate of coverage is not transferable except after notice to the Division of
Water Quality. The Division of Water Quality may require modification or revocation and
reissuance of the certificate of coverage.'. This permit does not affect the.legal requirements
to obtain other permits which may be required by the Division of Water Quality or permits
required by the Division of Land Resources, Coastal Area Management Act or any other
federal or local governmental permit that may be required.
Per the requirements of the Neuse Riparian Buffer Rule, all stormwater drainage
to stream buffers, from portions of.this site that have been constructed after July 22, 1997,
must be discharged through a correctly designed level spreader or another device that
meets diffuse flow requirements per 15A NCAC 213.0233. Diffuse flow requirements are
described in Chapter 8 of the North Carolina Stormwater BMP Manual, available at:
http/portal.ncdenr.org/web/wq/ws/su/bmp-manual.
Please note that permit requirements in Part 1I, Section A, numbers 1-5, and Part II,
Section B, number 1 are no longer valid per NC Session Law 2011-394. However, note that
Part 11, Section A, number 6, and Part II, Section B, numbers 2-10 are unaffected by this
Session Law. Those sections will remain in effect for the duration of this permit term. Your
facility must notify the appropriate DWQ Regional Office at least 72 hours in advance of
operation of your wastewater treatment facility.
If you have any questions concerning this permit, please contact Bethany
Georgoulias at telephone number (919) 807-6372.
Sincerely,
ORIGINAL M MD BY
BETHANY GEORGOULIAS
for Thomas A. Reeder
cc: Central Files
Wake County
Raleigh Regional Office
Stormwater Permitting Unit Files -
Jon Risgaard, DWQ, Aquifer Protection Section, Land Application Unit
Dan Werenko, P.E./ Withers & Ravenel/ 111 MacKenan Dr./ Cary, NC 27511
enclosure
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF WATER QUALITY
GENERAL PERMIT NO. NCG140000
CERTIFICATE OF COVERAGE No. NCG140427
STORMWATER AND WASTEWATER DISCHARGES
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
In compliance with the.provision of North Carolina General Statute 143-215.1, other lawful
standards and regulations promulgated and adopted by the North Carolina Environmental
Management Commission, and the Federal Water Pollution Control Act, as amended,
Eagle Rock Concrete, LLC
is hereby authorized to discharge stormwater and process wastewater from a facility
located at
Eagle Rock Concrete - Pristine Water Drive
500 Pristine Water Drive
Apex
Wake County
to receiving waters designated as an unnamed tributary (UT] to Middle Creek, a class
C;NSW water in the Neuse River Basin, in accordance with the effluent limitations,
monitoring requirements, and other conditions set forth in Parts 1, I1, III, IV, VI, Vll, and VIII
of General Permit No. NCG140000 as attached.
This certificate of coverage shall become -effective July 26, 2013.
This Certificate of Coverage shall remain in effect for the duration of the General Permit.
Signed this day July 26, 2013.
ORIGINAL G! 1NED BY
BETFi�;I-iY G� �GOUf<fA�
for Thomas A. Reeder, Acting Director
Division of Water Quality
By the Authority of the Environmental Management Commission
WITHERS & RAVENEL
ENGINEERS I Pt_ANNERS I SURVEYORS
115 MacKenan Drive
CARY, NORTH CAROLINA, 27511
(919) 469-3340
FAX (919) 467-6008
TO: NCDENR
512 N. Salisbury St.
Archdale Building, 91h Floor
Raleigh, NC 27604
WE ARE SENDING YOU ® Attached via
❑ Shop Drawings ® Prints
❑ Copy of Letter ❑ Change order
LEMR OF T ° N _9)MdUU1U
DATE 7/22/2013
100 NO. 2120170.00
ATTENTION Bethany Geor oulias
PHONE # (919) 807-6372
RE: Eagle Rock — Pristine Water Drive
�j Plans
❑ Diskette
_ the following items:
❑ Samples ❑ Specifications
COPIES
DATE
NO.
DESCRIPTION
2
7/22/13
Revised Sheet 4 of plans
THESE ARE TRANSMITTED as checked below:
® For approval ❑ Approved as submitted ❑ Resubmit copies for approval
❑ For your use ❑ Approved as noted ❑ Submit copies for distribution
® As requested ❑ Returned for corrections ❑ Return corrected prints
❑ For review and comment ❑
❑ FOR BIDS DUE 20 ❑ PRINTS RETURNED AFTER LOAN TO US
REMARKS: Bethany,
Please find the attached revised plan as requested. Thanks for your help. T
If enclosures are not as noted, kindly notify us at once.
Werenko, Dale
From: Georgoulias, Bethany [bethany.georgoulias@ncdenr.gov]
Sent: Friday, July 19, 2013 1:05 PM
To: Fisher, Ryan; Werenko, Dale
Subject: RE: Eagle Rock Concrete, LLC - Pristine Water Drive Site
Follow Up Flag: Follow up
Flag Status: Flagged
Ryan and Dale,
The Raleigh Regional Office has given approval for us to proceed on this application for coverage under the NCG
permit. I am just requesting that you submit a revised copy of Sheet 4 of the plans (two copies) with the notation about
seeking a non -discharge recycle permit removed.
Instead of a separate permit from APS, DWQ will authorize any overflow that discharges from the recycle system in rare
instances under the COC for NCG14. The fact that the design incorporates the 25-year, 24 hour storm event and
freeboard of a non -discharging system sufficiently addresses the alternatives analysis of non -discharge options for the
wastewater that will be produced here. This is an important element of our review because this permit includes
wastewater discharges under the NPDES program.
If you have any questions, let me know. If we can get that revised plan sheet from you in the next week, I'll plan to issue
this COC next week.
Best regards,
Bethany
Bethany Georgoulias
Environmental Engineer
NCDENR I DWQ I Stormwater Permitting Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
512 N. Salisbury St, Raleigh, NC 27604
Phone: (919) 807-6372
Fax: (919) 807-6494
NEW Website: http://portal.ncdenr.org/web/wq/ws/su
E-mail correspondence to and from this address may be subject to the North Carolina Public
Records Law and may be disclosed to third parties.
From: Georgoulias, Bethany
Sent: Thursday, July 11, 2013 2:23 PM
To: 'dwerenko@withersravenel.com'
Subject: Eagle Rock Concrete, LLC - Pristine Water Drive Site
Hi Dale,
I am reviewing the NO1 application from Eagle Rock Concrete, LLC for the Pristine Water Drive site in Apex for coverage
under the NCG140000 Stormwater/Wastewater General Permit. I apologize for our delay in the review —we have been
down several staff positions for a while and were also very busy with our first round of electronic general permit
renewals in May and June.
I have contacted the Raleigh Regional Office for their concurrence with issuing a certificate of coverage for this site.
They may or may not conduct a site visit prior to giving their approval. I'll keep you updated on when I hear back from
their office.
Thank you for all the helpful detail on the plans. I thought they were well prepared. As I reviewed the NOI and plans, I
noticed that the company plans to build a closed -loop recycle system that will meet the 15A NCAC 2T .1000 rule criteria.
Sheet 4 of the plans also says "A Non -Discharge recycle permit will be sought from the NCDENR-DWQ." However, our
Aquifer Protection Section staff say they have not seen an application for a recycle system permit from this company
yet. Is the company still planning to pursue that?
Right now we would issue the COC for stormwater discharge only according to the application, but I want to be clear on
what the plan is.
Thanks for your help in clarifying it.
Regards,
Bethany Georgoulias
Environmental Engineer
NCDENR I DWQ I Stormwater Permitting Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
512 N. Salisbury St, Raleigh, NC 27604
Phone: (919) 807-6372
Fax: (919) 807-6494
NEW Website: http://Portal.ncdenr.org/web/wq/ws/su
E-mail correspondence to and from this address may be subject to the North Carolina Public
Records Law and may be disclosed to third parties.
Geor oulias, Bethan
From: Smith, Danny
Sent: Wednesday, July 17, 2013 9:33 AM
To: Georgoulias, Bethany
Cc: Parnell, David; Risgaard, Jon
Subject: RE: NOI for NCG140000 from Eagle Rock Concrete - Apex Site
Bethany,
am good with this. Let me know if you need anything else.
Danny Smith
Regional Supervisor
Raleigh Regional Office
Division of Water Quality
Surface Water Protection Section
3800 Barrett Drive
Raleigh, NC 27609
(919) 791-4252
Danny.Smith@ncdenr.gov
Email correspondence to and from this address may be subiect to the North Carolina Public Records Law and may be
disclosed to third parties unless the content is exempt by statute or other regulotion.
From: Georgoulias, Bethany
Sent: Thursday, July 11, 2013 1:39 PM
To: Smith, Danny
Cc: Parnell, David; Risgaard, Jon
Subject: NOI for NCG140000 from Eagle Rock Concrete - Apex Site
Hi Danny,
Attached is an NOI application from Eagle Rock Concrete, LLC for a new facility in Wake County (Apex). The company is
requesting coverage under NCG14 stormwater + wastewater general permit.
They will discharge stormwater to a UT to Middle Creek (Class QNSW) in the Neuse Basin. Operation was scheduled to
begin in June 2013, but I'm behind on these. I'm not sure of the status of the site. They have proposed a non -discharge
recycle system for all the process wastewater, including aggregate spray down. The NOI, and plans indicate they would
pursue a non -discharge permit, but Jon Risgaard in APS says they haven't seen anything from these guys. I will follow up
with the consultant about it today or tomorrow.
The plans were prepared by Withers & Ravenel (Dale Werenko, P.E.), and they're pretty decent. I'm attaching the N01,
and I'll forward a copy of the plan sheets to the RRO (to Dave Parnell's attention, if that's okay). Please let us know if
the Raleigh Regional Office have any concerns with issuing a COC for this site.
Normally we'll plan to issue the COC if we don't hear from you in 30 days, but we wait on NCG14 and NCG02 permits
until we have confirmation from the regional office. Thanks for your help with this one.
Thanks,
Bethany
Bethany Georgoulias
Environmental Engineer
NCDENR I DWQ I Stormwater Permitting Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
512 N. Salisbury St, Raleigh, NC 27604
Phone: (919) 807-6372
Fax: (919) 807-6494
NEW Website: htt :11 ortal.ncdenr.or lweb/w /wslsu
E-mail correspondence to and from this address may be subject to the North Carolina Public
Records Law and may be disclosed to third parties.
Georgoulias, Bethany
From: Georgoulias, Bethany
Sent: Tuesday, July 16, 2013 12:28 PM
To: Smith, Danny
Cc: Parnell, David; Risgaard, Jon; Pickle, Ken; Bennett, Bradley; Thornburg, Nathaniel
Subject: RE: NOI for NCG140000 from Eagle Rock Concrete - Apex Site
Guys,
An update on this one. After the consultants at Withers & Ravenel looked into the permitting process for the recycle
system, some very typical things happened:
1) When investigating the application and process for an APS Recycle System Permit, they discovered there were
hardly any other concrete recycle systems permitted in the state and weren't sure how to start that process, or
why that might be. And then...
2) They read the 2T rules and thought their design met the deemed permitted requirements. The rules are not
very clear to explain "water used to removed concrete from equipment" is only drum washout water and does
not include washing the exterior of the vehicle (which vehicle washing exemption does, but that has to be
closed to precipitation inputs), and this trips a lot of people up in their interpretation. The aggregate pile spray
is also included (although, in this particular case it is settled drum washout water that drains back to the
system), and often people don't realize stockpile spray can't be an input either. [Basically, there are many
ready -mix plant "recycle systems" that really don't meet the permitted by rule option because they're capturing
several types of wastewaters in the recycle system].
3) We all agreed that while it is fantastic that they have designed a system to recycle water and hold the 25-year,
24-hour storm to prevent discharges from occurring (particularly from an engineering alternatives analysis
standpoint), it is just simpler to include authorization to discharge under the NPDES permit NCG14 in the very
rare event that it would ever overflow. I'm pretty sure this is APS's preference in most cases os well, but we
struggled with the authority to permit recycle systems under NCG14, and with our pending move to DEMLR in
August, �'m.even fuzzier on what: thisjrneons for0e NCG14 permit
So, we will just permit everything under the NCG14 permit. I'll have them resubmit revised plans so the notation that
they are pursuing a non -discharge permit is removed. Otherwise, 1 think everything looks okay, so I just need RRO's go
ahead whenever you all are ready.
Thanks,
Bethany
Bethany Georgoulias
Environmental Engineer
NCDENR I DWQ j Stormwater Permitting Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
512 N. Salisbury St, Raleigh, NC 27604
Phone: (919) 807-6372
Fax: (919) 807-6494
NEW Website: http:/Iportal.ncdenr.orglweblwplwslsu
E-mail correspondence to and from this address may be subject to the North Carolina Public
Records taw and may be disclosed to third parties.
From: Georgoulias, Bethany
Sent: Thursday, July 11, 2013 1:39 PM
To: Smith, Danny
Cc: Parnell, David; Risgaard, Jon
Subject: NOI for NCG140000 from Eagle Rock Concrete - Apex Site
Hi Danny,
Attached is an NOI application from Eagle Rock Concrete, LLC for a new facility in Wake County (Apex). The company is
requesting coverage under NCG14 stormwater + wastewater general permit.
They will discharge stormwater to a UT to Middle Creek (Class C;NSW) in the Neuse Basin. Operation was scheduled to
begin in June 2013, but I'm behind on these. I'm not sure of the status of the site. They have proposed a non -discharge
recycle system for all the process wastewater, including aggregate spray down. The NOI and plans indicate they would
pursue a non -discharge permit, but Jon Risgaard in APS says they haven't seen anything from these guys. I will follow up
with the consultant about it today or tomorrow.
The plans were prepared by Withers & Ravenel (Dale Werenko, P.E.), and they're pretty decent. I'm attaching the NOI,
and I'll forward a copy of the plan sheets to the RRO (to Dave Parnell's attention, if that's okay). Please let us know if
the Raleigh Regional Office have any concerns with issuing a COC for this site.
Normally we'll plan to issue the COC if we don't hear from you in 30 days, but we wait on NCG14 and NCG02 permits
until we have confirmation from the regional office. Thanks for your help with this one.
Thanks,
Bethany
Bethany Georgoulias
Environmental Engineer
NCDENR I DWQ I Stormwater Permitting Unit
1617 Mail Service Center, Raleigh, INC 27699-1617
512 N. Salisbury St, Raleigh, NC 27604
Phone: (919) 807-6372
Fax: (919) 807-6494
NEW Website: http://portal.ncdenr.orglweb/wq/ws/su
E-mail correspondence to and from this address may be subject to the North Carolina Public
Records Law and may be disclosed to third parties.
Georgoulias, Bethany
From: Risgaard, Jon
Sent: Monday, July 08, 2013 1:46 PM
To: Georgoulias, Bethany
Subject: RE:
Bethany,
They do not have a permitted closed loop system through APS.
Do you have some time to talk about these?
Jon Risgaard - Supervisor, Land Application Unit, Aquifer Protection Section
1636 Mail Service Center
Raleigh, NC 27699-1636
919-807-6456
http://h2c.enr.state.nc.us/lau/main.htmi
From: Georgoulias, Bethany
Sent: Monday, July 08, 2013 1:42 PM
To: Risgaard, Jon
Subject:
Hi Jon,
This NCG14 Ready -Mix discharge permit application says the company (Eagle Rock Concrete, LLC) is building a recycle
system for wastewater that will meet 02T requirements (p. 4, Q. 17). It's located in Apex. Are you all in the process of
permitting (or did you already) a system for this site? I just wanted to verify their Notice of Intent application was
accurate, and what the status of that project was.
Thanks so much!
Bethany
Bethany Georgoulias
Environmental Engineer
NCDENR I DWQ I Stormwater Permitting Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
512 N. Salisbury St, Raleigh, NC 27604
Phone: (919) 807-6372
Fax: (919) 807-6494
NEW Website: http://portal.ncdenr.orq/web/wgtws/su
E-mail correspondence to and from this address may be subject to the North Carolina Public
Records Law and may be disclosed to third parties.
SECTION .1000 — CLOSED —LOOP RECYCLE SYSTEMS
15A NCAC 02T .1001 SCOPE
This Section applies to closed --loop recycle systems in which nondomestic wastewater is repeatedly recycled back
through the process in which the waste was generated. The following systems are not regulated by this Section:
(1) the reuse or return of wastewater from a permitted animal waste lagoon facility for waste flushing
cover by Section .1300 of this Subchapter;
(2) the recycling of wastewater from groundwater remediation systems through an Injection Well or
Infiltration Gallery specifically covered by Section .1600 of this Subchapter; and
(3) the reuse of wastewater through treatment and distribution as reclaimed water specifically covered by
Section .0900 of this Subchapter.
Ilistory Note: Authority G.S. 143-215.1; 143-215.3(a);
Eff. September 1, 2006.
15A NCAC 02T .1002 RESERVED FOR FUTURE CODIFICATION
15A NCAC 02T.1003 PERMITTING BY REGULATION
(a) The following systems are deemed permitted pursuant to Rule .0113 of this Subchapter provided the system meets
the criteria in Rule .01 13 of this Subchapter and all criteria required for the specific system in this Rule:
(1) Return of wastewater contained and under roofwithin an industrial or commercial process where there
is no anticipated release of wastewater provided the facility develops and maintains a spill control plan
in the event of a release and no earthen basins are used.
(2) Recycling of rinse water at concrete mixing facilities for concrete mix removal from equipment
provided the wastewater is contained within concrete structures, there is sufficient storage capacity to
contain the runoff from a 24-hour, 25-year storm event plus one foot freeboard and the facility
develops and maintains a spill control plan in the event of a wastewater release. The facility must
notify the appropriate Division regional office in writing noting the owner, location, and that the
design complies with the above criteria.
(3) Recycling of wash and rinse water at vehicle wash facilities provided the wastewater is contained
within concrete, steel or synthetic structures (i.e. not including earthen basins), all vehicle washing is
conducted under roofand there are no precipitation inputs (direct or indirect), and the facility develops
and maintains a spill control plan in the event of a wastewater release.
(4) The reuse or return of wastewater within the treatment works of a permitted wastewater treatment
system.
(b) The Director may determine that a system should not be deemed permitted in accordance with this Rule and Rule
.0113 of this Subchapter. This determination shall be made in accordance with Rule .01 13(e) of this Subchapter.
Hisioly Note: 4u1hori1y G.S. 143-215. 1; 143-215,3(a):
Eff. September 1, 2006
15A NCAC 02T.1004 APPLICATION SURMITTAL
(a) A general description including how the wastewater is generated, how the wastewater will be recycled, and
contingencies in case of system failure shall be provided to the Division.
(b) Engineering design documents. If required by G.S. 89C, a professional engineer shall prepare these documents. The
following documents shall be provided to the Division by the applicant:
[Note: The North Carolina Board of Examiners for Engineers and Surveyors has determined, via letter dated December
1, 2005, that preparation of engineering design documents pursuant to this Paragraph constitutes practicing engineering
under G.S. 89C.1
(1) engineering plans for the entire system, including treatment, storage, application, and disposal
facilities and equipment except those previously permitted unless those previously permitted are
directly tied into the new units or are critical to the understanding of the complete process;
(2) specifications describing materials to be used, methods of construction, and means for ensuring quality
and integrity of the finished product;
(3) engineering calculations including hydraulic and pollutant loading for each treatment unit, treatment
unit sizing criteria, hydraulic profile of the treatment system, total dynamic head and system curve
analysis for each pump, and buoyancy calculations; and
NORTH CAROLINA ADMINISTRATIVE CODE Elf. January I, 2009 48
A�Division of Water Quality / Surface Water Protection
w
NCDENRNational Pollutant Discharge Elimination System
NomH Gvro ❑cr+.ar..EHr or
EMn ..E--0 HAS — ftl CE!
NCG140000
NOTICE OF INTENT
FOR AGLNCY IiSF ONLY
[.Talc Received
Year Nlunlh
Dav
Cerlificule 01 coverage
4
Check p Amount
0-00137
Permit A.SSI d 1a
�-
National Pollutant Discharge Elimination System application for coverage under General Permit
NCG140000:
STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with activities classified as:
SIC (Standard Industrial Classification) Code: 3273 and like activities - Ready Mixed Concrete
This NOI may be an application to discharge process wastewater. NCG140000 contains effluent limitations for
process wastewater discharges. Wastewater discharges must meet the requirements of these effluent
limitations. An exceedence of any of these limitations will result in a violation of the permit conditions.
For questions, please contact the DWO Central Office or Regional Office in your area. (See page 6)
(Please print or type)
1) Mailing address of owner/operator (official address to which all permit correspondence will be
mailed): (Please print or type all entries in this application form.)
Legal Owner Name Eagle Rock Concrete, LLC
(Please attach the most recent Annual Report to the NC Secretary of State showing the current legal name. Alternatively this
permit can be given to an individual.)
Signee's Name (as signed for in question 29 below) Adam Loftin
Street Address 8310 Bandford Way
City Raleigh State NC ZIP Code 27615
Telephone No. (919) 781-3744 Email adam@eaglerockconcrete.com
Alternate Contact Name Email (if different)
Alternate Contact Telephone (if different)
2) Location of facility producing discharge:
Facility Name
Facility Contact
Street Address
City
County
Telephone No.
Eagle Rock Concrete - Pristine Water Drive
Lyman Austin
500 Pristine Water Drive
Wake
(919)418-9178
State NC ZIP Code 27539
Fax:
3) Physical location information:
Please provide narrative directions to the facility (use street names, state road numbers, and distance and
direction from a roadway intersection). Located approximately 0.5 miles southeast of the intersection of
Pristine Water Drive and NC Highway 55!
(A copy of a county map or USGS quad sheet with facility clearly located on the map is a required part of this application.)-,—.•---- -
4) Latitude 35042'28"N Longitude 78°49'43"W (deg, min, sec) 0 °]
5) This NPDES Permit Application applies to the following pp pp g {check all that apply):
® New or Proposed Facility Date operation is to begin June 2013 A� `' ZD3
i�
❑ ExistingFacility Permit #
Y FrS?9Ltfi1'. 1
riw
Page 1 of 7
SW U-229-11032011
NCG140000 N.O.I.
6) Consultant's application information:
Consultant: Dale Werenko, P.E.
Consulting Firm:
Mailing Address:
City: Cary
State: NC
Withers & Ravenel
111 MacKenan Dr.
Phone: 9( 19 1 469-3340
Zip Code: 27511
Fax: 9( 19 1 467-6008
Email: dwerenko@withersravenel.com
(Optional)
Staple Business Card Here:
7) Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary
industrial activity at this facility:
SIC Code: 3 2 7 3
8) Provide a brief description of the types of industrial activities and products produced at this facility:
(Attach a site diagram showing the process areas present at this facility.)
Production of ready mix concrete and outside storage of aggregate.
Stormwater Discharge, Wastewater Treatment & Discharge and Permitting Information
9) Discharge points I Receiving waters:
Number of discharge points (ditches, pipes, channels, etc.) that convey stormwater and/or wastewater from
the property:
Stormwater-only: 1 Wastewater -only: Wastewater Commingled with Stormwater:
For new facilities: Expected date of commencement of discharge: June 31, 2013
What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater
and/or wastewater discharges end up in? Unnamed Tributary of Middle Creek
Receiving water class ification(s), if known: C; NSW
If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm
sewer system (e.g. City of Raleigh municipal storm sewer). N/A
Will this facility discharge wastewaterto SA (Shellfishing) waters? ❑ Yes X No
Note: Discharge of process wastewater to receiving waters classified as WS-Ii to WS-V or SA must
be approved by the N.C. Division of Water Resources, Public Water Supply Section. If DWR
does not approve, coverage under NCG140000 cannot be granted. No new discharges of
process wastewater are permitted in receiving waters classified as WS-1 or freshwater ORW.
10) Each applicant shall provide the following information (attach additional sheets as necessary):
• Two (2) site plans depicting the facility or site with numbered outfalls which indicate stormwater and
wastewater outfalls. The plans shall legibly show. at a minimum, (existing or proposed):
o Outline of drainage areas with topographical lines and features
o Stormwater/wastewater treatment structures
o Location of numbered stormwater/wastewater outfalls (corresponding to which drainage areas)
o Runoff conveyance structures
o Areas and acreage where materials are stored
o Impervious area acreages
o Location(s) of streams and/or wetlands the site is draining to, and any applicable buffers
o Site property lines, North Arrow, and bar scale
Page 2 of 7
S W U-229-a 7122011
NCG140000 N.O.I.
o If applicable, the 100-year floodplain line
o Acreage of each stormwater and wastewater topographical area
a Each of the facilities' wastewater or stormwater source and discharge structures and each of its
hazardous waste treatment, storage, or disposal facilities
o Site location (insert)
Site plans shall be 24" x 36" in size.
• Line drawing and description: Aline drawing of the water flow through the facility. A pictorial
description of the nature and amount of any sources of water and any collection and treatment measures.
• A narrative description and identification of each type of process, operation, or production area which
contributes wastewater to the effluent for each outfall, and a description of the treatment the wastewater
receives (or will receive), including the ultimate disposal of any solid or fluid wastes other than by
discharge. Processes, operations, or production areas may be described in general terms (e.g. "ash silo").
11) Does the applicant have any unresolved Notice of Violations (NOVs)?
X No ❑ Yes
Wastewater:
12) What types of wastewater does your facility generate or discharge?
Type of Authorized Wastewater
Generate
Discharge
Sent to WW
Treatment
System
Vehicle and equipment cleaning VE
®
❑
❑
Wetting of raw material stockpiles (RM)
®
❑
❑
Mixing drum cleaning MD
®
❑
❑
Further explanation, if necessary: A closed -loop recycle system is proposed to prevent discharge of wastewater.
13) Will your facility spray -down or actively wet aggregate piles?
❑ No ® Yes
14) Does the facility use any of the following on site?
❑ Phosphorus -containing Detergents ® Non -Phosphorus -containing Detergents
❑ Brighteners ❑ Other Cleaning Agents ❑ Other:
15) Are wastewater treatment facilities planned in the 100-year flood plain?
® No ❑ Yes
16) Does your facility use or plan to use a recycle system, or recycle components in your treatment system?
® Yes ❑ No
If yes, what size storm event is the system designed to hold before overflowing? (for example, f 0-yr, 24-hr)
25 year, 24-hr rainfall event
Page 3 of 7
SW U-229-07122011
NCG140000 N.Q.I.
^ 17) Will your facility build a closed -loop recycle system that meets design requirements in 15A NCAC 02T
1000 and hold your facilities' working volume'?
1
® Yes ❑ No
Will your facility discharge wastewater to surface waters?
❑ Yes ® No
If the facility's treatment system meets the design requirements of 15A NCACO2T .1000 (including
holding the 25-year, 24-hour storm plus one foot of freeboard), holds the working volume of your site,
and does not discharge wastewater to surface waters, you may not be required to obtain an NPDFS
permit for wastewater discharges. If you believe this is the case, please contact DWQ's Aquifer Protection
Section Land Application Unit Central Office Supervisor or staff (1636 Mail Service Center, Raleigh, NC
27699-1636) for more information on obtaining the necessary permits or approvals. If you will discharge
wastewater or stormwater to surface waters, please continue to apply for a permit to discharge associated
with ready -mixed concrete or like operations under NCG140000. For further questions, please contact
DWQ's Stormwater Permitting Unit Staff.
18) A wastewater treatment alternatives review is required by 15A NCAC 2H.0105 (c)(2) for any new or
expanding water pollution control facility's discharge in North Carolina. You may attach additional sheets.
a) What wastewaters were considered for this alternatives review? ❑ VE ❑ RM ❑ MD
b) Connection to a Municipal or Regional Sewer Collection System:
i) Are there existing sewer lines within a one -mile radius? ..................................... N Yes ❑ No
(1) If Yes, will the wastewater treatment plant (WWTP) accept the wastewater? .... ❑ Yes ® No
(a) If No, please attach a letter documenting that the WWTP will not accept the wastewater.
(b) If Yes, is it feasible to connect to the WWTP? Why or why not?' The facility will utilize a
closed -loop recycle system to reuse the wastewater generated for truck washing, aggregate
wetting, and batch mixing orocesses.N_ o wastewater will be conveyed to_the _Town of Apex's
sanita(y sewer network for treatment.
c) Closed -loop Recycle System (must meet design requirements of 15A NCAC 2T .1000):
Are you already proposing a closed -loop recycle system (CLRS)? I) Yes ❑ No
(1) If Yes, contact DWQ's Aquifer Protection Section's Land Application Unit
(2) If No, is this option technologically feasible (possible)? Why or why not?"
(3) If No, is it feasible to build a CLRS on your site? Why or why not?"
(4) What is the feasibility of building a CLRS compared to direct surface water discharge?`
d) Surface or Subsurface Disposal System (e.g., spray irrigation):
Is a surface or subsurface disposal technologically feasible (possible)? ....................❑ Yes N No
See DWQ's Aquifer Protection Section Land Application Unit's Water Balance Calculation Policy for more information, on DWQ LAU's
website htto:l/porial.ncdenr.orolweblwolaps/lau/policies for more information.
Page 4 of 7
5W U-229-07122011
NCG140000 N.O.I.
Why or Why not? _A closed -loop recycle system is proposed to eliminate the need for surface or
subsurface disposal of wastewater.
ii) Is a surface or subsurface disposal system feasible to implement?* ...........................❑ Yes M No
Why or Why not? Wastewater disposal is not proposed for this project due to a closed -loop recycle
system is proposed to use generated wastewater to wash down trucks, spray aggregate piles and for
batch mixin .
iii) What is the feasibility of employing a subsurface or surface discharge as compared to a direct
discharge to surface waters?* Direct discharge of wastewater is not proposed due to the closed -loop
recycle system is proposed to reuse/recycle the wastewater generated for truck washing, aggregate
wettano and batch m'x1na.
e) Direct Discharge to Surface Waters: Is discharge to surface waters the most environmentally sound
alternative of all reasonably cost-effective options of the wastewaters being considered?*...❑ Yes ® No
i) tf No, contact DWQ's Land Application Unit to determine permitting requirements.
f) If this review included all wastewater discharge types, would excluding some types (e.g. raw
stockpile wetting) make any of the above non -discharge options feasible? ..............❑ Yes N No
You may be asked to provide further information to support your answers to these questions after the initial review.
Feasibility should take into account initial and recurring costs.
Stormwater:
19) Does this facility employ any best management practices for Stormwater control? ❑ No ® Yes
If yes, please briefly describe: Wet Detention Pond
20) Does this facility have a Stormwater Pollution Prevention Plan? N No ❑ Yes
If yes, when was it implemented? SWPPP will be completed by June 2013 _
21) Are vehicle maintenance activities (VMA) occurring or planned at this facility? ❑ No ®Yes
If yes, does your VMA area discharge into your wastewater treatment device? ❑ No ® Yes
Other/Permitting: ***Truck wash down area will flow into wastewater recycle facility.
22) Does this facility have a Division of Land Resources Erosion & Sedimentation Control (E&SC) Permit?
❑ No ® Yes
If yes, list the permit numbers for all current E&SC permits for this facility: Town of Apex - Permit # 12-014
23) Is your facility subject to Phase II Post -Construction Area? ® Yes ❑ No
If yes, who is the permitting authority? Town of Apex
24) Is your facility located in one of the 20 Coastal Counties? ❑ Yes N No
Is your facility adding more than 10,000 ft2 of built -upon area or CAMA Major Permit? ❑ Yes ❑ No
Page 5 of 7
SW U-229-07122011
NCG140000 N.O.I.
25) Is your facility discharging wastewater (treated or untreated) such as water from wetting of aggregate piles,
drum rinse -out, or vehicle and equipment cleaning to a stormwater BMP? ® No ❑ Yes
If yes, please attach your approval from the permitting authority to do so.
26) Does this facility have any other NPDES permits? ® No ❑ Yes
If yes, list the permit numbers for all current NPDES permits for this facility:
27) does this facility have any Non -Discharge permits (ex: recycle permits)? ® No ❑ Yes
If yes, list the permit numbers for all current Non -Discharge permits for this facility:
28) Hazardous Waste:
a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility?
® No ❑ Yes
b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of
hazardous waste?
®No El Yes
c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of
hazardous waste?
® No ❑ Yes
d) Type(s) of waste:
How is material stored. NIA
Where is material stored: NIA
How many disposal shipments per year: NIA
Name of transport 1 disposal vendor: NIA
Vendor address: NIA
Final Checklist
This application will be returned as incomplete unless all of the following items have been included:
® Check for $100 made payable to NCDENR.
® This completed application and all supporting documentation. See Question 10.
If an Erosion & Sedimentation Control (E&SC) Plan is required from Division of Land Resources (DLR)
or local designee: documentation verifying applicant. has developed and submitted that Plan to the
governing agency (required per 15A NCAC 02H .0138).
—f ® Two (2) site plans depicting the site plan with numbered outfalls which indicate stormwater and wastewater
1 outfalls. See Question 10.
® A county map or USGS quad sheet with location of facility clearly marked.
29) Signatory Requirements (per 40 CFR 122.22)
All applications, reports, or information submitted to the Director shall be signed and certified.
a. All notices of intent to be covered under this General Permit shall be signed as follows:
(1) For a corporation: by a responsible corporate officer. For the purpose of this permit, a responsible corporate officer means: (a) a president,
secretary, treasurer or vice president of the corporation in charge of a principal business function, or any other person who performs similar
policy or decision making functions for the corporation, or (b) the manager of one or more manufacturing production or operating facilities
employing more than 250 persons or having gross annual sales or expenditures exceeding 25 million (in second quarter 1980 dollars), if
authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures.
(2) For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or
(3) For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official.
Page 6 of 7
SW 1f-229-07122011
NCG140000 N.O.f.
Certification: North Carolina General Statute 143-215.6 B(i) provides that:
Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other
document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of
a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate
any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental
Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten
thousand dollars ($10,000).
1 hereby request coverage under the referenced General Permit. I understand that coverage under this permit will
constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual
permit.
I certify that I am familiar with the information contained in this application and that to the best of my knowledge
and belief such information is true, complete, and accurate.
Printed Name of Person Signing: Adam Loftin
Notice of Intent must be accompanied by a check or money order for $100.00 made payable to: NCDENR
Mail the entire package to:
Stormwater Permitting Unit
Division of Water Quality
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
Note
The submission of this document does not guarantee the issuance of an NPDES permit.
For questions, please contact the DWQ Regional Office for your area.
DWO Regional Office Contact Information:
Asheville Office ......
(828) 296-4500
Fayetteville Office ...
(910) 433-3300
Mooresville Office ...
(704) 663-1699
Raleigh Office ........
(919) 791-4200
Washington Office ...(252)
946-6481
Wilmington Office ...
(910) 796-7215
Winston-Salem ......
(336) 771-5000
Central Office .........(919)
807-6300
s " ftgt��aillnJ
Page 7 of 7
S W U-229-07122011
rdtxs�.rrrillc:
�sHeeLr;gEi
• ,4Vti3hit,vl�di
r i
., t n}• rtriv Itis,�— 1
!" W:Ir��ii:ttturi
4.
4-
Md.
THE PEAK Or 0000 OWNG
4/5/2013
Eagle Rock Concrete, LLC
8310 Bandford Way
Raleigh NC 27615
Re: Letter of Plan Approval
Project Name:
Eagle Rock Concrete
Project Location
Pristine Water Drive
Project Number:
12-014
Submitted By:
Withers & Ravenel
Date Submitted.
1/7/2013
Sroam 01 4:79�ac
P. O. BOX z5c)
APrX. NORTH CAROLINA 27502
The Soil Erosion and Sedimentation Control Plan (S&E) you submitted has been
reviewed and accepted. The Town of Apex (Town) hereby issues this Letter of Plan
Approval. The Town's S&E program is performance oriented, requiring protection of the
natural resources and adjoining properties. If at any time during this project it is
determined by Town staff that the approved S&E Plan is inadequate to meet the Town's
S&E ordinance, this office may require revisions to the S&E Plan and its implementation
to ensure compliance with the S&E ordinance (Section 5-154).
In accordance with Section 5-158 of the Town's S&E ordinance, you are hereby notified
that this office has the right to periodically inspect any land -disturbing activities to ensure
compliance with the approved S&E Plan and ordinance. You are to notify this office
twenty-four (24) hours before starting work. You are also required to keep the working
drawings on site.
Stormwater runoff generated from sites disturbing more than one (1) acre is permitted
pursuant to the National Pollution Discharge Elimination System (NPDES) administered in
North Carolina by the Division of Water Quality (DWQ). Attached is the General
Stormwater NPDES Permit, NCG010000, reissued on August 3, 2011. You are
responsible for complying with the General Permit requirements and are subject to
enforcement actions by DWQ for any viloations of the General Permit.
",!
Letter of Plan Approvat
Page 2 of 2
The Contractor will be permitted to clear only as necessary to install the required
S&E measures, Once the required S&E measures are installed, contact Public
Works staff to schedule an on -site inspection. A Certificate of Compliance will be
issued after a site inspection is completed to ensure that the S&E measures are
installed per the approved S&E Plan. Please note that a Certificate of Compliance is
required prior to receiving a grading permit From the Building Inspections Division.
The approval of an S&E Plan is conditioned on the applicant's compliance with Federal
and State water quality laws, regulation, and rules. In addition, the Town's NPDES Phase
II permit requires site contractors to control construction site wastes that may cause
adverse water quality impacts. please have your site contractor review the attached Town
Construction Site Waste Management Plan to become familiar with the requirements.
Town staff will inspect your site to ensure these water management practices are being
implemented. You will need to provide evidence of compliance, if applicable.
I look forward to working with you on this project and if you have any questions, please
call (919) 249-1166.
Regards,
Stan Fortier, PE Date
Environmental Programs
f�fryle�7il�p:
� �+�,ww� �rw,`w •i r
6-r 3
078' 51'00.00" W 078' 50' OOM" W I I 078' 49' 00.00" W
4_jM 4'jq
N11
z
ko
C3
LO
ro
0
vt""
J
"5 Va
-7,
Ne
NA
V.
C'
b
Ln
LO
jji'e/V
VIN
\�;`
�!
Eagle Rock Pristine Water
O
- j�
}° ��f,�,
7-;
ISP
Concrete Plant
IV
Lat: 35042'31.18"N
Long: 78049'43.60"W
NAD 83
0
✓2"
\V_
N
Q
j"
z
f
. 'j
C'j
zo
CO
N_
co
D
Ll 1.
r
678' 51' 00-00" VV I I 678" 50' 00.00" W 678' 49' 60.00" W
Datum: NAD83 Copyright (C) 1997, Maptech. Inc,
CONCRETE CHAMBER BOUYANCY CALCULATIONS - CLOSED LOOP RECYCLE SYSTEM
ji�
CHAMBER 1
EL 397.
2.5% MIN SLOPE I
INTO CHAMBER TANK
NOTE:
STRUCTURAL DESIGN BY OTHERS
CHAMBER 2
TO CHAMBER 1ME
AGGREGATE
STORAGE
TOP WALL
EL: 399.00
3' HIGH LI
EL 397.50P
- -MAXIMUM
STOWE-VOLUMEEU
95.25
4 BAFFLE OPENING
95. 5
WSEL IN CHAMBER
EL: 389.25
CONCRETE FLOOR
e-0"
50'-0r
10'-0'
NOTE:
CROSS-SECTION
C-C
STRUCTURAL DESIGN BY OTHERS
CROSS-SECTION D-D NOTE
STRUCTURAL DESIGN BY OTHERS
REINFORCED I
CONCRETE
ENTRANCE
L MIN SLOPE
I CHAMBER TANK
DESIGN ASSUMPTIONS
* WATER TABLE AT 393.00
* CHAMBERS 1, 2, & 3 WITH WASTEWATER TO ELEV. 395.25
* SOIL BEARING PRESSURE NEGLECTED
(WEIGHT OF STRUCTURE) + (WEIGHT OF WASTEWATER)
(UPLIFT FORCE)
WEIGHT OF STRUCTURE
WEIGHT OF CONCRETE IN CHAMBERS
WALLS - NORTH
= 46'L X 10.5'H X 1' W X 150 LB/FT3 X 1 WALL
= 31.51 X 9.75'H X 1' W X 150 LB/FT3 X 1 WALL
WEIGHT OF WATER DISPLACED BY CONCRETE CHAMBERS (UP TO EL 393.00)
= 41 X 8'H X 1' W X 150 LB/FT3 X 1 WALL
CHAMBER 1
= 123,319 LBS
= 97.15 SF X 12.33' = 1,197.9 CF X 62.4 LB/CF
WALLS - EAST
= 151 X 10.5'H X 1' W X 150 LB/FT3
= 74,746 LBS
= 22'L X 1O'H X 1' W X 150 LB/FT3
CHAMBER 2
= 20'L X 9.25'H X 1' W X 150 LB/FT3
= 97.15 SF X 11.67' = 1,133.74 CF X 62.4 LB/CF
= 84,375 LBS
= 70,745 LBS
CHAMBER 3
WALLS -SOUTH
= 97.15 SF X 12.33' = 1,197.9 CF X 62.4 LB/CF
- 46'L X 8.25'H X 1' W X 150 LB/FT3X 1 WALL
= 56,925 LBS
= 74,746 LBS
CHAMBER 4
WALLS -WEST
= 46,67 LF X 4.58 LF X 58 LF = 12,397.4 CF X 62.4 LB/CF
= 343.27 FT2X VW X 150 LB/FT3X 1 WALL
= 51,491 LBS
= 773,599 LBS
WALLS - INTERIOR BETWEEN CHAMBERS 1 &3
TOTAL = 993,837 LB
= 194.45 FT2X 8"W X 150 LB/FT3 X 2 WALLS
= 38,890 LBS
WALLS - INTERIOR BETWEEN CHAMBERS 3&4
= 245.752FT X 1'W X 150 LB/FT3X 1 WALL
37 013 LOS
ENTRANCE SLAB
= 10'L X 34.5'W X 8" D X 150 LB/FT3
1,335,454 LBS = 1.344 FACTOR OF SAFETY
= 34,500 LBS
93,837 LBS
FLOOR
= 82.5'L X 58'W X 10-D X 150 LB/FT3
- 598,125 LBS
TOTAL = 1 024 638 LB
WEIGHT OF WATER IN CHAMBERS 1, 2, & 3 (UP TO EL: 395.25)
CHAMBER 1
= 150.94 SF X 1 VW X 62.4 LB/CF
= 103,605 LBS
CHAMBER 2
= 150.94 SF X 1 VW X 62.4 LB/CF
= 103,605 LBS
CHAMBER 3
= 150.94 SF X 1 VW X 62.4 LB/CF
= 103,605 LBS
TOTAL = 3105816 LB
CHAMBER 4
NOTE:
STRUCTURAL DESIGN BY OTHERS
CONCRETE FLUME HAND RAIL
TO CHAMBER 1
AGGREGATE HAND RAIL
STORAGE
AREA TOP WAIL L: 399.75
i,-JT-P
/- TOP WALL EL: 397.50
397.50, . Required
396.50' Freeboard
1
Required Water Storage Area 9.75'
6.75'
6'
389.25 FLOOR I
56'-0"
CROSS-SECTION E-E
INSTALL BLACK METAL HAND RAIL RAILING
AROUND PERIMETER OR BASIN
EXCEPT ALONG RAMP SIDE
42" MIN HT
4'-O"
NORMAL WSEL
IN CHAMBERS 1-3
CHAMBER 1 CHAMBER 2 CHAMBER 3
CONCRETE FLOOR
11'-Cr 11'-o" j 11'-o" 1
MAXIMUM VOLUME WITHIN TANK
Q EL: 397.50
12" 12" FREEBOARD 0 EL: 396.50
6.75' DESIGN STORM
STORAGE VOLUME
CHAMBER 4
NORMAL WSEL
61 IN CHAMBER 4�
45'-2"
CROSS-SECTION A -A NOTE:
STRUCTURAL DESIGN BY OTHERS
AGGREGATE
BIN 3
w
U_
8' HIGH
2'X2'X6' CONCRETE I
AGGREGATE AGGREGATE BIN
C D BIN 4
Lit< UVLNING I
I
s'
CONCRETE FLUME
WASTEWA
R
OFF
ENTERS SETTLING CfAMBER
1
THROUGH 4' WIDE WEIR
NING
IN
WALL
CHAM
3ER 1
CHAM
ER 2
CHAM
ER 3
CHAMBER 4
4' WEIR OPENING
56' X 45'-2" X 6.75'
STORAGE CHAMBER
METAL H
WD RAIL ---,be
I
I
I
b\
cD
�
rD
z
CL
I
0-
0
0
LLJ
z
Q
uO
LO
ul
Ir
0Y
Y
U
m
4' WEIR OPENING
I
I
I
I
I
I
0 � o 0
CONCRETE E TRANCE RAMP
OVERFLOW FROM STORM EVENTS
GREATER THAN 25 YEAR-24 HR
WILL EXIT RECYCLE BASIN
I I I
B C D
SCNB 1' - 10'
DESIGN CALCULATIONS
STORAGE VOLUME FROM 25-YR 24-HR STORM EVENT
TOTAL TREATED SURFACE AREA TO WASTEWATER RECYCLE SYSTEM:
25-YEAR 24 HOUR STORM DEPTH (IN):
TOTAL DESIGN STORM VOLUME TO BE CAPTURED:
STORAGE VOLUME FROM TRUCK WASHING
AVG NUMBER OF TRUCKS/DAY:
AVG GALLONS OF WATER USED PER TRUCK WASHDOWN:
TOTAL VOLUME FROM TRUCK WASHING:
STORAGE VOLUME FROM DRUM RINSE -OUT
AVG NUMBER OF TRUCKS/DAY:
AVG GALLONS OF WATER USED PER TRUCK WASHDOWN:
TOTAL VOLUME FROM TRUCK WASHING:
E
METAL HAND RAIL I
I
E
SCALD 1 • - w
TRUCK
WASH RACKS
METAL HAND RAIL
37,1110 SF; 0.85 AC
5.84 IN (0.49')
18,184 CF; 136,026 GAL
5 TRUCKS AT 3 LOADS/DAY
15 GALLONS
225 GAL/DAY
15 TRUCKS AT 0.5 CY/TRUCK
15 GALLONS
7.5 CY; 56 GAL/DAY
TOTAL VOLUME REQUIRED TO BE CAPTURED: 225 GAL + 56 GAL + 136,026 GAL = 136,307 GAL; 18,222 CF
VOLUME PROVIDED: CHAMBER 4 (56' X 45' X 6.75') = 17,010 CF
AREA ABOVE NORMAL WSEL IN CHAMBERS 1-3 (60.25 SF X 32'-6") = 1,958 CF
TOTAL VOLUME PROVIDED: 18,968 CF; 141,891 GAL
12" FREEBOARD PROVIDED ABOVE REQUIRED STORAGE VOLUME: 86' x 45' x 1' = 3,870 CF; 28,950 GAL
MAXIMUM STORAGE VOLUME WITHIN RECYCLE SYSTEM: 28,950 GAL + 141,891 GAL = 170,841 GAL
PROJECT SUMMARY
A RECYCLE FACILITY HAS BEEN DESIGNED TO CAPTURE THE 25YR-24HR STORM EVENT PLUS TRUCK WASHING AND DRUM
RINSE -OUT WITHOUT DISCHARGE TO SURFACE WATERS. THIS DESIGN CONSISTS OF ISOLATING THE INDUSTRIAL OPERATIONS
FROM THE NON -INDUSTRIAL AREAS. SURFACE STORMWATER/WASTEWATER IS COLLECTED VIA CONCRETE SURFACE FLUMES
AND DISCHARGES INTO A SERIES OF CONCRETE CHAMBERS DESIGNED TO SETTLE SEDIMENT AND PROVIDE STORAGE AS
REQUIRED TO MEET NCDWQ REQUIREMENTS. RECYCLE/PROCESS WATER FROM THE LAST CHAMBER WILL BE PUMPED
OUT AND RE -USED TO IRRIGATE AND HYDRATE AGGREGATE STORAGE AREAS AND RE -USED IN PROCESSED BATCH
CONCRETE.
REFERENCES:
* NOAA ATLAS 14 VOLUME 2, VERSION 3, RALEIGH DURHAM PRECIPITATION FREQUENCY ESTIMATE CHART
Na
1
ReW im
Date
j -E � EAGLE ROCK -PRISTINE WATER DRIVE
APEX WAKE COUNTY NORTH CAROLINA
WASTEWATER RECYCLE SYSTEM DESIGN
NCDWQ Comments
07.22.2013
DW
-- .3:�z--
j 'fv� i ri',l� Ir�A ' I t' •.,r t r tag r .rt ' .i;. '.r'�
Desl�ner
WEIR
Stale
AS SHOWN
Drawn By
Date
RFrow
Checked I�r
Job Na
DW
2120170A0
WITHERS RAVEN EL
0
ENGINEERS i PLANNERS i SURVEYORS
115 MOcKenan Drive Cary, North Carolina 27511 tel: 919-469-3340 www.withersravenel.com License No. C-0832
Sheet Na
4
1. ___ .. a -...>>_..--. .,_, :L, ..- -, _ .. -_.. --__----'--_,•__ �.-. _- �._ �.r ."�.� � -. �� _3 . ��y
t
VICINITY MAP 1-_000
INDEX OF SHEETS
SHT No. DRAWING DESCRIPTION
1 OVERALL SITE & LOCATION PLAN
2 GRADING AND STORM DRAINAGE PLAN
3 WASTEWATER SITE/GRADING PLAN
4 WASTEWATER RECYCLE SYSTEM DESIGN
5 t WASTEWATER RECYCLE SYSTEM DETAILS
S1 FOUNDATION PLAN, SECTIONS &
GENERAL NOTES
GENERAL NOTES
1. BOUNDARY, TOPOGRAPHIC AND LOCATION SURVEY INFORMATION SHOWN IS TAKEN FROM AN ACTUAL SURVEY
BY SMITH do SMITH SURVEYORS, APEX, NORTH CAROLINA, DATED JUNE 2012.
2. AREAS COMPUTED BY COORDINATE METHOD.
3. BASIS OF BEARINGS: NC GRID NAD 83, (NSRS 2007).
4. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES.
5. THIS PROPERTY LIES WITHIN THE NEUSE RIVER BASIN, AND PORTIONS OF THE PROPERTY MAY BE SUBJECT
TO PROTECTIVE BUFFERS AS DEFINED BY NCDENR.
6. IRON PIPES SET AT ALL CORNERS UNLESS OTHERWISE NOTED.
7. THIS PROPERTY IS LOCATED IN A DESIGNATED FEMA FLOOD PLAIN AS SHOWN ON THE FEDERAL EMERGENCY
MANAGEMENT AGENCY FLOOD INSURANCE RATE MAP NO. 3720077800J,
PANEL 0778J, HAVING AN EFFECTIVE DATE MAY 2, 2006.
8. REASONABLE CARE HAS BEEN EXERCISED IN SHOWING THE LOCATION OF EXISTING UTILITIES ON THE PLANS.
THE EXACT LOCATION OF ALL EXISTING UTILITIES IS NOT KNOWN IN ALL CASES. THE CONTRACTOR SHALL
EXPLORE THE AREA AHEAD OF DITCHING OPERATIONS BY OBSERVATIONS, ELECTRONIC DEVICES, HAND
DIGGING AND BY PERSONAL CONTACT WITH THE UTILITY COMPANIES. IN ORDER TO LOCATE EXISTING
UTILITIES IN ADVANCE OF TRENCHING OPERATIONS SO AS TO ELIMINATE OR MINIMIZE DAMAGE TO EXISTING
UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RESULTING FROM ANY DAMAGE TO
THE EXISTING UTILITY LINES INCLUDING LOSS OF UTILITY REVENUES. CONTRACTOR SHALL ARRANGE FOR
TEMPORARY SUPPORT OF EXISTING UTILITIES, SUCH AS POLES, CONDUITS, FIBER OPTIC CABLES, TELEPHONE
CABLES, WATER LINES, ETC.
9. CONTRACTOR SHALL COMPLY WITH THE LATEST REVISIONS AND INTERPRETATIONS OF THE DEPARTMENT OF
LABOR SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION PROMULGATED UNDER THE OCCUPATIONAL
SAFETY AND HEALTH ACT.
10. CONTRACTOR SHALL PLAN AND CONSTRUCT WORK SO AS TO CAUSE MINIMUM INCONVENIENCE TO THE
OWNER AND THE PUBLIC. THE CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN AT ALL TIMES DURING
THE PROGRESS OR TEMPORARY SUSPENSION OF WORK, SUITABLE BARRIERS, FENCES, SIGNS OR OTHER
ADEQUATE PROTECTION, INCLUDING FLAGMEN AND WATCHMEN AS NECESSARY TO INSURE THE SAFETY OF
THE PUBLIC AS WELL AS THOSE ENGAGED IN THE CONSTRUCTION WORK. CONSTRUCTION SIGNING SHALL BE
IN ACCORDANCE WITH THE LATEST EDITION OF -CONSTRUCTION AND MAINTENANCE OPERATIONS SUPPLEMENT
TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES' BY THE DOT.
11. ALL MATERIALS CLEARED OR DEMOLISHED BY THE CONTRACTOR IN ORDER TO CONSTRUCT THE WORK SHALL
BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROPERLY DISPOSED OF OFF —SITE.
12. ALL WORK BY THE CONTRACTOR SWILL BE WARRANTED BY THE CONTRACTOR FOR A PERIOD OF ONE YEAR
AFTER THE OWNER ACCEPTS THE WORK.
13. CONTRACTOR SWILL CALL THE NORTH CAROLINA ONE —CALL CENTER AT 1 (800) 632-4949 AND ALLOW
THE CENTER TO LOCATE EXISTING UTILITIES BEFORE PROCEEDING WITH CONSTRUCTION.
WASTEWATER RECYCLE SYSTEM
EAGLE ROCK -
SCALE 1'- 1W
for
PRISTINE
WATER DRIVE
TOWN OF APEX, NORTH CAROLINA
April 25, 2013
I\
N
PROPERTY OF 'ICE L CASH
. DB 2463 PG 225
DB 5092 PG 614
BM 1911 PG 73
CURIWNT USE. VACANT
_GR,� — — — — — PRISTINE WATER DRIVE ZONING "
PRo1 "ERIY
OF
DOLE PIPE LINE COMPANY
0.8- 1936, PG. 328
B.M. 1970. PG. 106
CURRENT USE. UnUTY
zOMIN& U
N
PROD SRPSF Y OF
AGLE ROCK CONCRETE
9 15069, PG 001-OOJ
0,
SITE
awl
N F
OF
DUCHNNE PROPERTIES, LLC
D.B. 11476, PG. 2696
D.B. 12293, PG. 768
B.M. 2010, PG. 1053
B.M. 2008: M. 2341
B.M. 2002. PG. 922
CURRENT USE: CONCRETE MANUFACTURING
ZONING u
`\�111111 I11/1j1,
:\ oP�N°CARO��,,:
=o QoFESS I0 v
oe SEAL q
° 95 0
oo o
E
III11111�\\��Z`j
PROXTY
DUC AINE PROPERTES. LLC
O.B. 11476. PG. 26M
D.B. 12293- PG- 768
B.M. 2010. PG. 1053
B.M. 2008. PG. 2341
B.M. 2002. PG- 922
CURRENT USE- CONCRETE
MANUFACTURING
ZON ra u
USGS VICINITY MAP 1" = 21#000'
PREPARED BY:
WITHERS FZAVENEL
ENGINEERS I PLANNERS I SURVEYORS
115 MacKenan Drive Cary, North Carolina 27511 tel: 919-469-3340 www.withersrovenel.com License No. C-0832
Attn: Dale Werenko PE dwerenko@withersravenel.com
IV
•
C
OWNER/DEVELOPER
n
EAGLE ROCK CONCRETE, LLC
8310 BANDFORD WAY
RALEIGH, NORTH CAROLINA
PROJECT CONTACT- ADAM LOFTIN
TEL (919) 781-3744
FAX (919) 571-1521
A_
i
0
WCS
�r
UJ
U)ZN
J 0 0 M
U 0:...-
U 0- Z N
W
of F- tfj
Y W
w00af
C
wWa-
F-_jWUJ
3Lg�o
r
RESOURCE CONSERVATION AREA
LINE TABLE
LINE BEARING I DISTANCE
L1 N11722' E 310.25'
L2 S4719'54 E 58.94'
L
L71 N16'47'5TE 31.15'
U3 N5T08'11 E 72.21'
L9 N3410'3 E 59.65'
PRISTINE RIVE DB 2463 PG 225
EAPROPERTY OF/ALICE L CASH
x 70• sr DISTANCE D
srANCE WEME DB 5092 PG 614
60' INGRESS &EGRESS EASEMENT.
- - ivT BM 191 1 PG 73
_ — — — — — — — — — D.B. 2286, PG. 545 GROUND ND SIGN BM
USE: VACANT
G,AV& -- — — _ _ _ ZONING: U
PUBLIC R/W DEDICATION
— — — — — — — — — — R/W WIDTH VARIES
— -- — - - RE C L �-- - - 452
Ro — 8 SF; -0. 15 AC .
52535'X_.�.—�,�....- — X — — n— — 2.83' o is
_ ' — — S8T4T38"E 399.89'
Pm ` ��:.��..
10' X 70' SIGHT OISTANCE� \� ....NX 19.56'
TRIANGLE
r_ _
tt1 c10'TYPE D
S7REErFRONT \\ AO'R 40'R\`�\\\ p p
r NOTE. -_ - _ -_.• _ - -0- -
_ �y -gyp•
1 SIDEWALK FLUSH 42• 8 PAR ING SPACES 9
/ x PARKING LOT 1 (H/C)
EXISTIN
r
FENCE �' '°�-FLAGPOLE Vf
� � SIGN ••,
1 � ALK BENCH° •
I I A ,•-
z ;
1 U1 PRDPosED •
1 G �� I sEPnc FlELD � � � •
E N EMSrwc ► SIORY
N/F 1 42• U, METAL BURM c I �
PROPERTY OF SWING GATE r 25-RI 1 ° d
DIXIE PIPE LINE COMPANY r 10•R SIDEWALK 0 0
D.B. 1936, PG. 328 l ° 0 ° 0 0 wELL
B.M. 1970, PG. 106 r � � PAW STD Y � 0 CHAIN ;LINK FENCE
N C°NCRE►E •
CURRENT USE: UTILITY it .� �" �' GATE I SWING •
ZONING: LI BOLLARD I
(TYP) I :
174.72• RETaNrrvG w PROPERTY OF ' : FlIELDHIFFEHNC14.5 E W GA HIGH GHETTENSILE
1 EAGLE ROCK CONCRETE i ; FENCE POSTS 8' O.C.
1 DB 15069, PG 001— 003 I APPROX. 730 LF I •
la 1 •
� i •
e FUEL o I
1 471 TANK
� I :
1 � I
1 AGG BIN 2 I
o I
78' 1 4 lu I
� AGG 81N 1
1 31
31•
• 1s•
r 37. `
r
r
/ ENCLOSED DUMPSTER W/ /
1 rN_BlF CONCRETE MASONRY WALLS
1 /MATERIALS TRAILER
ry 1 78. (TYP)
42.
1 y,
1 AGG BIN 3 74• �a '� '
1 AM BIN 4
100' TOWN OF APEX D BING / yi
STREAM BUFFER
'_/ OROPERTY OF
x m W 1• CV" �� '� DUCHAINE PROPERTIES, LLC
RIB 9 �„� D.B. 11476, PG. 2696
C D. 12293, PG. 768
coQM. 2010, PG. 1053
R.M. 2008, PG. 2341
\ / _ B M. 2002, PG. 922
Z
) 1 - / CURRENT USE: CONCRETE
MANUFACTURING
Ln
CEMENT TRUCK .• '/• /
(TYP) ING: LI
1 ► wASTEwA Z - ,
RECYCLE SYSTEM a o
/ 20.ENCLOS e• ! . / / /
I I r cF 24'-6" x 8' x 9'<'R�A ,f /
I l f SHIPPING CONTAINER
WATER'S EDGE I 1 r 0� COLOR: TAN
/
lo
KA/DOU' / 1 \ • mod. ' -1 OU ✓SITRFA# t ._.:_,!- i - , i
01
/ j , / / •.• \ poll _ < / _ /1 / , _ , 1 NUAL CHANCE
BMP1 ) , , , , / /j % / % // / FL00 LAIN BOUNDARY
/ / / •• \� STORIrIWAIER MANAGEMENT fACILRY y/• -, '/_ /! i '/ - PER FEMA FIRM •
:/i ✓ _�/_ /! < ••�• /r''� j� I NG/C / Ki/ MAP 3720077800J •
i / / % / •� � FEMA FLOODPLAIN LIMITS
/ / /' f' , � !' ' i / •.� EDGE OF RCA ' •
EDGE OF WETL�cNDS�.•'
To
GENERAL SITE NOTES
1 I • / . /. W-,11,�A-N E!T •D 8 _/ _ / , .. _ / i / < -/ /- - /- f -/ - •i /- - •
/ - EDGE OF STR BU ' ' —
/ < < < / iE Ti Pv N D S / <
I � /
• \/ _
/ l • �-'� \ / / / //',��<- f -/ /- ,� - - -R - -20' TOWN OFiAPEX
/ / • ♦ i ' ' / ! < /_ / �.' ' ' ' ' / < / / �/� /' ' 1046 �.69 SF'' �' , — PUBLIC GREQVWAY EASEMENT
-% '
7 / / /' '
N87'4948"W NF
529�6' - - •
} PROPERTY OF
UC INE PROPERTIES, LLC
D. 11476, PG. 2696 •:
D.B. 12293, PG. 768
B.M. 2010, PG. 1053
B.M. 2008, PG. 2341
B.M. 2002, PG. 922 ;
CURRENT USE: CONCRETE MANUFACTURING
ZONING: U
� vm
sale r = 50'
Cllerlaed &r
Job Na
DW
2000000
APEK WAKE COUNTY NORTH CAROUNA
EAGLE ROCK -PRISTINE WATER DRIVE
1 � �
' I I
soo'
F�
' I
/
/�500' FROMTMIENT/
STORAGE U
COMPLIANCE BOUNDARY
COMPLIANCE BOUNDARY LIMITS
ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF APEX AND/OR NCDOT
STANDARDS & SPECIFICATIONS.
2. BOUNDARY INFORMATION TAKEN FROM AN ACTUAL SURVEY BY SMITH & SMITH
SURVEYORS MAY 2012.
3. SOLID WASTE COLLECTION FOR THIS PROJECT WILL BE HANDLED THROUGH A PRIVATE
CONTRACTOR. A DUMPSTER WILL BE LOCATED ON SITE.
4. AREAS COMPUTED BY COORDINATE METHOD.
5. BASIS OF BEARINGS: NC GRID (NAD 83)
6. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES.
7. METAL STAKES SET AT ALL CORNERS UNLESS NOTED OTHERWISE.
8. THIS PROPERTY LIES WITHIN THE NEUSE RIVER BASIN, AND PORTIONS OF THE
PROPERTY MAY BE SUBJECT TO PROTECTIVE BUFFERS AS DEFINED BY NCDENR.
9. THIS PROPERTY IS LOCATED IN A DESIGNATED FEMA FLOOD PLAIN AS SHOWN ON THE
FEDERAL EMERGENCY MANAGEMENT AGENCY FLOOD INSURANCE RATE MAP NO.
3720077800J, PANEL 0778J, HAVING AN EFFECTIVE DATE MAY 2, 2006.
OVERALL SITE & LOCATION PLAN
1" = 200'
SUMMARY INFORMATION TABLE
DEVELOPMENT NAME EAGLE ROCK
PLANT — PRISTINE WATER DRIVE
LOCATION/ADDRESS
500 PRISTINE WATER DRIVE
OWNER NAME AND ADDRESS
EAGLE ROCK CONCRETE, LLC
8310 BANDFORD WAY
RALEIGH, NC 27615
WAKE COUNTY PIN
0751-02-9412
DEED BOOK & PAGE
DB 15069 PG 0001-0003
TOWNSHIP
WHITE OAK
ZONING DISTRICT
(LI) LIGHT INDUSTRIAL
EXISTING USE
COMMERIAL EQUIPMENT STORAGE
PROPOSED USE
CONCRETE BATCH PLANT
TOTAL ACREAGE
9.60 AC
OPEN SPACE
0.00 AC
WATERSHED
MIDDLE CREEK
SECONDARY WATERSHED PROTECTION OVERLAY
DISTRICT
EXISTING BUILDING (GSF)
3000 SF — ONE STORY OFFICE
EXISTING BUILDING TYPE
STEEL/CONCRETE CONSTRUCTION
PROPOSED BUILDING (GSF)
0 SF
NUMBER OF STORIES :
1
BUILDING HEIGHT:
SEE ARCHITECTURAL PLANS
NO AUTOMATIC SPRINKLER SYSTEM PROPOSED
INSIDE CITY LIMITS
NO, ANNEXATION REQUIRED
LINEAR FEET OF PUBLIC STREETS
0 LF
PARKING REQUIREMENTS
PARKING REQUIRED (1 SPACE/200 SF OF GROSS FLOOR AREA) 15
PARKING PROVIDED
23 SPACES (1 VAN ACCESSIBLE)
15 TRUCK STORAGE SPACES
% OF PARKING IN REAR/SIDE OF BUILDING: 79 %
METHOD OF GARBAGE CONTAINMENT
DUMPSTERS
(PRIVATE CONTRACTOR)
RESOURCE CONSERVATION AREA (RCA):
RCA REQUIRED ( 25 % OF 9.60 AC)
104,544 SF 2.40 AC
RCA PROVIDED ( 25 %)
104.652 SF 2.40 AC
IMPERVIOUS SURFACE AREA:
4.40 AC (45.8%)
TOTAL DISTURBED AREA:
7.3 AC
SETBACKS
FRONT
20 FEET
SIDE YARD
20 FEET
REAR YARD
20 FEET
MAXIMUM HEIGHT:
85 FEET
MAXIMUM BUILT UPON AREA ALLOWED:
70%
CURRENT 2025 LAND USE DESIGNATION:
INDUSTRIAL EMPLOYMENT
PROPOSED 2025 LAND USE DESIGNATION:
INDUSTRIAL EMPLOYMENT
MAXIMUM BUILT UPON AREA ALLOWED
70.0 %
292,723 SF; 6.72 AC
TOTAL BUILT UPON AREA PROPOSED
45.8 %
191,500 SF; 4.40 AC
NO HISTORICAL STRUCTURES LOCATED ON
PROPERTY
COMMUNITY AMENITIES (UDO SEC 8.4.3)
FLAGPOLE, CONCRETE BENCH
20 OF_SSip•e'L ;
oQQ` ti9
SEAL
95
0 2F w 100' 20D' =e F
e `L
9• �� z5
fJlllE1 �t�' ►►►►►Ili��ti��`
ENGINEERS I PLANNERS I SURVEYORS
115 MacKenan Drive Cary, North Carolina 27511 tel: 919-469-3340 www.*ithersravenel.com License No. C-0832
CONSTRUCTION`�\ \i -� ENTRANCE
---- -_ ` ---_i6--409-- 410-\ _---------
8---- ---- - ___
N / ` ' + , ............ f ...............
... .:....p� : r� i_ ' PE ASPIOIMTI
-1If CIP O.,4:93X y -
- X - 7a \ \ -----z 110:7.E IN HR,' •... /
•�•- . .........
it
I i1 f
f . /
` ` I FFE 407.56 /' / ~ t
•LL CONTRACTOR SHALL
SILT INSTATREE PROTECTION FENCE
TO FENCE ,g \ r 1 ,i t 1; ; / •/ PROTECT SEPTIC FELD
p „ ELL
•TREE' PROTECTION FENCE
LIMITS \ . _ . .' i ! I , ! ! , •
SIT FENCE
r ! i j i i i ro Il Tull .S,:r, ;•:n/-POFLk�,'i&"
LOUTS OF CONSTRUCTION
/
' + r•.l ` QQ t I r !,1!rlZ71a 2_�378 -
+"
-? + � ,/ 10
\•
if
INSTALL iE1EORATIY r! i' /. I ! !i� - 4� '�/ / / / /' /� /� 0� / /,/ /l f r
OIVEitS10N OITCFI Tb t i $ / ,%
SESKD E0j\ 8ASN i I v/' P I -' ' j ' / /" '/
l r r rn ' IN /OiTQH M
ON PLAN !! %1,1/0�•' ! I l !• /' I
1 % -
1 / f 1 /
INSTALL ROCK", CHECK � % , r i ; \ \ r' : ; , • _ ,
N DIVERSION DITCH IN LOCATIONS
SHOWN ON PLAN in \ : i !'/� / / / I !•
dD
', it 1--- __ _ ._.,',%' � � � �)l�r,Ir/i / �� I / /•, I
id I
PETi11ANANT GRASS-Lll!ED SMIALE _ l,l -
SEE Typr#L CROSS-SECTION SHEET 14
'iIg.71 !z2
t
I •-I
D1-1 ,! I 1
tf
.39o- \r? \ r / `! t !IIII !!!!', / • / I !
J)f( Q�/) \ I , 11 ,IIII • /.
-----'__`;=_`��s �`\ � \ \ , rr % it yi} ! t }N ;;..�: �___-- r !',,t,l ! ;•
- \ • ` ` ` ` ` , \ `, . it � � ,� I ' , r I . ,/ -
?r,,rrll,r/II ,s
if
\ � --3$y _\ + `1 \ it � III /. __-= "_ ! // ��/,!/,/,. + /} • / /� /•// /
UL
DHOMT OT '_ r :'_
r - ! ' 1 ! 1 ! \ ALL BOXES SHALL HAVE A RAISED SEDIMENT
/ r \ ;1 , \', 1 , 1 \ CONCRETE SLAB TOP.
TYPICAL DETAIL
P0. `rZ_ 22;
POkA ENT GRASS -um
SEE TdnM CROSS-SOMM SHEET 14
r / rr INSTALL INLET PROTECTION "/ • ii' // ' _ - _ c' /
/u;3.1:1 SLOPE
/ ,' AT -ALL INLETS (iYP) ��� /i/�,���, �• -
1 /
/ d !I+!t�! i•I! ,! --.\\\ ' '//- i�%ii�/� \ W E T L N S
DI101 DI102 M-
Do:180 AC Da:2.00 AC /,'' /;;�r./�%i• %_ _ _ _ - - ;� - /
C�.75 C•0.75
Q10:9.75 CFS 010:10.83 CFS
1 !,// / '�•; !!1 _ `IIII / y_0.. // /ii/�/,/7/j/ r / _-_ _ �G/ /
18'
19 .11
I ' I ' (+ l 'I• / SI �� 8,� ! I"„'}J�4 �i/,•! /// t r I•Ldl �• 1_ ' / /
� r' rr f r i tr,/i i /� 3�� •.' / / /jp'' _ ;;= - %sue � /% ,/ ,�� O _ 16'� - - + !++ ,, - /'.
/ / ALL FOfiE8A11' \ �
-
STOtI1ITNATER Jet
-- 4kAPLE 20 Bi� -' --- - - ; '• ' ' -/ - - -FLC
t
71
ii rl 1!//l1;� i,1 , •/ ! I - 11P _ •�� / - 7 f - _ - - /- -!
t tf 'fill,
ll'fr/ �•r/ I ! r /f _ ACCESS'
S'APEX
RI ARI BUFFER_ I //
- /
�g r:. Irr,• W.E:T I. A_N.D S-ZONE 2 - - \ _ -
/'/rr•, r . NEUS1=:.� _ •E T A N d S
r , ,rl r --�• I - - - - 'f RIPARI "BU R
20
ZONE
1 / r%,; r'+r•'+'� \ \ _ , / :7 _ /NE RIVE
i'"r+fi f'ii ' i \ - - - - * - - - • - -. !• .30. T 'RI RTAN' FER - t
/; r r; ri r; •/ - �: --- - - - \ _ .1 %--- I"4. _ OF BAN _ ,: --
•
• \ ,, _IT_ OF BAN
20 L ZONE
- TOWN - APEX
-j - - - 50 ? RIP LAN BUFFER '
_ r - _ ZONE 2
^'`' _ - - --
c15 ' ; NEUSE-RIVE
/ �' \ �* ' // ' - RIPARIAN- B R
k/ /
DSOW
WWu
sch
r = 50'
Dow a►
iwDW
ode
4rnm
Owdwd By
lob NIL
DIN
zwvuw
APEX
7. NUAL CHANCE
I LAIN BOUNDARY
PER FEMA FIRM
MAP 3720077800J
•
•
♦
•
•
•
•
•
•
•
•
•
•
•
•
♦
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
EAGLE ROCK • PRISTINE WATER DRIVE
WAKE COUNTY
GRADING NOTES
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WiTH CURRENT TOWN OF APEX STANDARD SPECIFICATIONS & DETAILS
2. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO BEGINNING
CONSTRUCTION.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL
DEVICES SHOWN ON THE APPROVED PLAN.
4. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE STABIUZED WiTH TEMPORARY SEEDING AND MULCHING
WITHIN NPDES STABIUZATION TIMELINES FOLLOWING COMPLETION OF GRADING. PERMANENT SEEDING, MULCHING
AND GROUND COVER SHALL BE APPLIED TO THE SiTE FOLLOWING COMPLETION OF CONSTRUCTION.
5. THIS SITE IS LOCATED IN THE SECONDARY WATERSHED PROTECTION OVERLAY DISTRICT.
GENERAL NOTES
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF APEX STANDARDS & SPECIFICATIONS.
2. CONTRACTOR SHALL CONTACT NC ONE -CALL AT 811 A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION ACTIVITIES.
3. ON -SITE TOPOGRAPHIC INFORMATION PROVIDED BY SMITH & SMITH SURVEYORS, APEX, NC
4. THE EXISTING UTILITIES SHOWN ON THE PLANS IS BASED ON THE BEST AVAILABLE INFORMATION, BUT CAN BE CONSIDERED ONLY
AS APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS INFORMATION AND UTILITY LOCATIONS PRIOR TO
COMMENCEMENT OF WORK ON SITE. ANY POTENiiAL CONFLICTS WiTH PROPOSED CONSTRUCTION SHALL BE REPORTED TO THE
PROJECT ENGINEER FOR REVIEW PRIOR TO BEGINNING CONSTRUCTION.
5. THERE IS FEMA MAPPED FLOOD PLAIN LOCATED ON THIS PROJECT PER FiRM MAP NUMBER MAP NO. 3720077800J, PANEL 0778J,
HAVING AN EFFECTIVE DATE MAY 2, 2006.
6. TOPSOIL SHALL BE WASTED OFFSITE OR AT APPROVED STOCKPILE AREA ON SiTE.
7. CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL STRUCTURES DURING THE LIFE OF THE PROJECT.
8. CONTRACTOR SHALL CONSTRUCT DIVERSION DITCHES AS NECESSARY TO ENSURE ALL SEDIMENT IS DIRECTED INTO EROSION
CONTROL MEASURES.
9. AREAS COMPUTED BY COORDINATE METHOD.
10. BASIS OF BEARINGS: INC GRID (NAD 83)
11. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES.
12. THIS PROPERTY LIES WITHIN THE NEUSE RIVER BASIN, AND PORTIONS OF THE PROPERTY MAY BE SUBJECT TO PROTECTIVE BUFFERS
AS DEFINED BY NCDENR.
13. A REFUNDABLE PERFORMANCE GUARANTEE WILL BE REQUIRED IN THE AMOUNT OF S2500 PER DISTURBED ACRE AND IS DUE PRIOR
TO CONSTRUCTION DRAWING APPROVAL
14. NAME OF RECEIVING WATER: MIDDLE CREEK
STORM DRAINAGE NOTES
1. ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WiTH THE TOWN OF APEX SPECIFICATIONS AND DETAILS.
2. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. THE LOCATION OF
EXISTING UTILITIES SHOWN ON THE PLANS IS BASED ON THE BEST AVAILABLE INFORMATION, BUT CAN BE CONSIDERED ONLY AS
APPROXIMATE.
3. ALL STORM DRAINAGE PIPE SHALL HAVE A MINIMUM COVER OF 2 FEET TO THE PIPE CROWN IN TRAFFIC, UNLESS APPROVED.
4. ALL STORM DRAINAGE PIPE SHALL HAVE A MINIMUM COVER OF 1 FOOT TO THE PIPE CROWN IN NON -TRAFFIC AREAS.
5. STORM SEWER SHALL BE REINFORCED CONCRETE PIPE (RCP) CONFORMING TO ASTM C76, TABLE III OR TABLE IV. JOINTS SHALL BE
SEALED WiTH A PLASTIC CEMENT PUTTY MEETING FEDERAL SPECIFICATIONS SS-S-00210, SUCH AS RAM-NEK OR BUM RUBBER SEALANT.
6. STORM SEWER PIPE ENDS SHALL BE FURNISHED WITH REINFORCED CONCRETE PIPE FLARED END SECTION UNLESS OTHERWISE
SPECIFIED ON PLANS.
7. EACH DRAINAGE STRUCTURE SHAD_ HAVE A SHAPED INVERT CONSTRUCTED FROM CONCRETE, AND A BENCH WITH A MAXIMUM 5:1
SLOPE. THE BENCH SHALL BEGIN AT A HEIGHT OF ONE-HALF THE PIPE DIAMETER FOR 12 TO 24 INCH PIPE, ONE-THIRD THE PIPE
DIAMETER FOR 30 - 48 INCH PIPE, AND ONE-FOURTH THE DIAMETER FOR PIPE GREATER THAN 48 INCHES.
8. ENERGY DISSIPATERS SHALL BE INSTALLED AT ALL STORM SEWER DISCHARGE POINTS. A FABRIC OR WASHED STONE BARRIER SHALL
BE INSTALLED BETWEEN THE DISSIPATION PAD AND THE NATURAL GROUND.
9. ALL STORM DRAINAGE EASEMENTS SHALL BE *PRIVATE UNLESS OTHERWISE SPECIFIED.
10. STORM PIPE TRENCH EXCAVATION AND BACKFiLLING SHALL BE PERFORMED IN ACCORDANCE WITH TOWN OF APEX STANDARD
SPECIRCAT10NS AND DETAILS.
11. FES: FLARED END SECTION, CB: CATCH BASIN, JB: JUNCTION BOX, DI: DROP INLET W/ RAISED CONCRETE SLAB TOP.
12. RIM ELEVATION GIVEN FOR CB IS TOP OF CURB (T/C), DI IS TOP OF BOX (NOT SLAB), MH IS TOP OF RIM.
SITE PEAK ATTENUATION SUMMARY
Storm Event
Pre -Development
Peak Flow
cis)
Post -Development
Peak Flow w j / BW
cfs
Net
Change
CIS)
Net
Change
z
1-Year
6.01
1.18
-4.83
-80.4z
10-Year
20.46
15.96
-4.50
-22.OX
100-Year
35.65
31.10
-4.55
-12.8%
NORTH CAROUNA
BMP 1 - WET DETENTION POND
OUTFLOW SUMMARY
PEAK FLOW SUMMARY - POND DATA
PDS-based point precipitation frequency estimates with 90% confidence intervals (in inches'
Duration
Average recurrence interval (years)
����
10
Z5
50
t00
®
500
1000
0.395
0.462
0.530
0.588
0.648
0.691
0.729
0.762
0.797
0.824
resin
(0.363-0.430
(0.424-0.504
(0.487-0.578)
(0.539-0.640
(0.592-0.705)
(0.628-0.751)
(0.559-0.793)
0.685-0_S30)
0.711-0.865,
{0.729-0.899}
0.631
0.739
0.848
0.941
1,03
1.10
1.16
121
1.26
1.30
10-min
(D.579-0.68T
(D.677-0.806
(0.780-0.925)
(0-862-1.02)
(0.943-1.12)
1 (1.00-1.20)
{1.05-125)1
(1.09-1.32)
(1.12-1.37J
(1.15-1.42)
0.789
0.928
1.07
1.19
1.31
1.39
f.47
1.52
19
1.63
15-min
(D_724-0.859'
(D_852-'L01)
(D.987-1.77)
(1.09-1.34j
(7.20-i_42)
(1.27-1.52)
(1.32-1.59)
(1.37-1._JF(1,4i!1,73)1F
0.44-1.78}
1.08
128
f.53
1.73
1.94
Z70
224
23T
2.53
Z64
30-min
(0.993-1.18J
(1.18-1.40}
{1.40-1.66)
{7.58-1.85)
(1.77-2.11)
(1.91-228)
1 (213-2.44)
1 (2.13-2.58)
(225-2.75)
(2-33-2.88)
1.35
1.6t
1.96
Z25
2.58
3.09
3.33
3.62
3.85
60-min
(124-1.47)
(1.48-1.76)
{7.80-213)
(2.06-2A4)
(2.36-Z81)
(2.59-3.09}
�
(279-3.3Sj
1 12.99-3.621
1 (323-3.95)
(3.41-4.20)
1.56
1.87
2.30
3.09
3.45
3.79
4.12
4.55
4.89
2-hr
.266
{1.43-1.72)
(1.71-2.05)
(2.10-252)
(2.41-2-91)
(280-3.38)
(3.11-3.77)
(3-39-4.13)
(3.67-4.50)
(401-4.96)
(428-5.35)
1.66 1
F 1.99
2.45
Z85
3.35
3.77
4.18
4.60
5.15
5.61
3-itr
(1.52-1.82)
(1.82-2_18)
(224-2.68)
(260-3.72)
(3.04-3.66)
(3.40-4-11)
{3.74-4.56)
t4.09-5A7)
(4-0 5. 22)
(4.88-6.13)
ZOt
2.40
2.96
3.45
4.08
4.60
5.13
5.67
633 -9--1
TOO
6-hr
(1.85-Z19)
I (Z21-2.62}
1 (2.72-323)
(3.15-3.75)1
(3.71-4.42)
1 (4.16-4.99)
1 (4.60-5.55)
1 (5.04-6.13)
(5.61-5.91) 11(6.07-7.59)
12-h r
2.38
2.85
131-21
4.13
U4.?9:2�:j
5.59
6.27
6.99
7.96
8.80
(263-3.10)
(325-3.83)
(3.80-4.49)
(5.06-6.02)
(5.62-6.75)
(6.19-7-51)
(6.94-$.56)
(7.56-9.47)
24-fir
Z84
(266-3_Q4)
3.42
(3.21-3.6T)
4.28
1 (4-90-4.58)
4.94
(4.62-5.29)
5.84
(5.44-6.25) 111(6.08-7.01)
6.55
7.27
{5.73-7.79)
8A0
(7.39-8.59)
9.00
(828-9.68J
9.78
{8.96-10.5}
2-day
328
3.94
4.8$
5.61
7.34
8.1f
8.88
9.93
1b.7
(3.06-3.52}
(3.68-4.24}
(4.56-525}
(5.23-6.03)
11 (6.11-7.0Tj 11
(6.80-7.89)
(7.49-8.72j
(8.17 9.57)
10-10.7)
(9.81-11.6)
3.47
4.76
5.f3
5.89
6.91
7.71
8.5f
9.33
10.4
11.3
3-day
(324-3.72)
1 (3.89-4.47)
{4.80-v.51}1
(5.50-6.32)
(6.42-7.41)
p_75-827}
(7.879.75)1
(8.60-10.0)
(9.58-17.3)
(10.3-1Z2)
3.66
4.38
5.39
6.17
7.23
8.07
8.92
9.79
1 -1.0-7
71.9
,tea y
(3.43-3.92)
(4.10-4.69)
(5.04-5.76)
(5.77-6.61)
(6.74-7.75)
(7.50-8.66)
(826-9.58)
(9.02-10.5)
1 (10.1-11.8)
(10.8-12.8)
424
5.05
6.13
6.98
8.t4
9.05
9.98
10.9
i22
132
7-day
(3-SS-4.52)
(4-75-5-39)
(5.76-6.55)
(6.55-7.45)
(7.61-$_69)
(8.44-9.68)
(928-10.7)
(10.1-11_7)
(11.3-13.7)
(12-1-14.2)
4.81
5.71
6.85
7.T5
8.95
9.90
10.9
11.8
13.1
7-1
74.1
10-da y
(4-53-5.13) 11
(5.37-6.09)
1 (6.44-7.31)
(727-826)
(8.38-9.55)
(924-10.6)
(10_1-11.6)
(11.0-12-7)
(121-14.1)
(13.0-15.2)
6.42
7.58
8.94
16.0
11.5
i2.7
13.9
15.0
i6.7
iT9
20-day
(6.05-6.85)
(7.13-8.07)
{8.41-9.53)
(9.42-10.7)
(10.8-123)
(11.8-13.5)
(1Z9-74.8
(13.9-16.1)
(15-4-17.9) 1
(16.4-19.3)
T97
9.38
t0.9
12.1
t3.6
14.8
16,0
17.2
18.7
t9.9
38-day
(7-52-8.48)
(8.83-9.96)
1 (10-2-11-6)
(11.3-12-8)
(128-14.5)
(13.9-15.8)
(149-17.0)
(16.0-18.3)
(17.4-20.0)
(18.4-21.4)
10.2
i1-9
13.6
14.9
16.7
18.0
19.3
20.6
2Z3
23.5
43-day
(9.66-10.7)
(11.3-12.6)
(12.9-14.4)
(14.2-15-8)
(15.8-17.6)
(17.0-19.0)
(182-20.4)
(19.3-21.8)
(20.8-23.6)
122
142
16.1
17.5
19.3
20.6
21.9
23.2
24.8
26.0
60-day
(17.6-1Z9)
(13.6-15-0)
{15.3-16.9)
{16.5-18.4)
(18.3-20_3)
q 5-21.8)
{20.7-23_2)
(21.9-24.5)
{23.3-26.3)
(24.4-27.6)
Precipitation frequency (PF) estimates in This table are based on frequency analysis of partial duration series (PDS)_
Numbers in parenthesis are PF estimates at loner and upper bounds ofthe 9D% confidence interval. The Probability that precipitation frequency estimates (far a
given duration and average recurrence kftrval) will be greater than the upper bound (or less than the lower bound) is 5%. Estimates at upper bounds are not
checked against probable maDdmum precipitation (PMP) estimates and may be higher than currently valid PMP values.
Please refer to NOAA Atlas 14 doc unentfor more informafim
Peak Water
Freeboard
Total
Storm Event
Surface Elevation
(ft)
Peak Outflow
(ft)
(Cfs)
1-Year
382.65
2.35
0.86
10-Year
383.32
1.68
10.02
100-Year
383.80
1.20
18.74
GRADING AND STORM DRAINAGE PLAN
N C Aq
O,12
09
SEAL Co
5 0 -
\
7,
WALE 1'-1110'
WITHERS & RAVEN EL
ENGINEERS 1 PLANNERS I SURVEYORS
115 MacKenan Drive Cary, North Carolina 27511 tel: 919-469-3340 www.wbmramel.com License No. C-0832
Shut Na
2
------------------------ ----___------------------------ - —_— - _ \--�,..���,.•• 1 4 y ������ �j ����
,; 1-- _--------- __ ------------------------------__----------__-- ---------------------------, _ `- _ _.� - '----------` ''— - ^```� 1 4
Is
I 394 396 394 392 ________________________=__-----__-"_-- __------_____-- ` _----------- 'n� p�N000--
_= ---__-_---------------------------------- __-- ----- -- '- uoa�► + -
77
-41' _-__---- ---_-__ --_-_- _----- — _- _- _-- _- _-_--_-_- ___----__ ___ __ _ __ \\
- _-_-_------------------------------- _
'S°� 397--------------- _ __; -_ ___ - 4
_ - - ---- _
__' 39 x - - ______ _____
• 0� w 9 to396 -----------� _
ch
4 PR
DUMPER x g \
n n to
0) `
0
O br , I -------------------
-
40
--------------------
r -
--------------- 39
I
,Io
0
I ,
O g
r l l
1 rl)1 ,
i1 1 1�•'I 1 '
I
I 0
� o
m
Old g
, r r
r
I r
I r 1 r (
1
1 1 1
M 4WM
� 1
r r
�'I I o
� t I
I
I I !
1
! � g
r !f r l I g g
; I Ii 1 fr x
! I
r
rf
r , /
1' o
t 0
1 �
j1
tr
it I o
- 1 0
I
3 �
' I I
i
I 1 Ir I
a
i
i I
I 1
r ,
I
I
,
Xo
IN 1f WIDE ONCRETE EDGE CLOSED LOOP RECYCLE
39
WITH SED UP TO
REVENT MIXING
SYSTEM AREA
A
F WASTEWA
/STORMWATER
37.110 SF; 0.85
AC
PERMX FROM TEED SEPARATELY
o
ch
TRACK WASH RACK
INSTALL 12" WIDE CON EDGE
WITHRAISED XINR
TRUCK WASH srnu
g
OFWASTEWATER ORM
A
CD
n�
\
CONCRETE
TRACK "SN RACK
R.
_
NTRANCE
A
o
rl�—
M ;
o
RAMP
X
n A
__ o
- -._..
TRUCK M+ASF1 yTALL
B B
v
n
x
o0 00
:..... _. _. -- v
x
0 : n
of
K
B
D (TYP.)
_.
.
w
„� x
B
0
Y
0 0
r• t
_may M
... .
j cy
T
oy
s
A
O
o,
CO
t O
4
v
8'
HIGH WALL AGGREGATE BI WALL
a
n
n 3992s 399.zs
A
.25
MR
38925, 397.50
g
8' HIGH
—
_
2'X2'X6'
CONCRETE BLOCK
AGGREGATE BIN WALL
g
I
I
I
A
=
�
E
E CHAMBER 4
I h
I c
1 y
_ 10,000 RAca
U 'WATER
n
\
\
56' X 45'-Z X 5.75' STORAGE CHAMBER
` t
(32'-2'X8'- 9'K3 H)
397.
o0
—_
0
Scr
it
BAFFLE OPENING
o
'
8 g
CONVEYOR
d'
g
Y
'
CONVEYOR
1"
o
SUPPORT C
iA
---
SUPPORT
,on
CONVEY
.25
1
gx
SUPPORT
,p x N
8
389.25
J
CONVEYOR 2
4.2'
$
I
I
47.50
397.50 397.50
X X
u� o
I x
og
I cm
°
y,
w
CHAMBER 3
X389.*
50' RAMP O 16X
397.25 AA A
v g
C
' N
f-
" p
T
39D. 3".25395.25
g
�w
ag
o
°
°
_ `•
N
in
iA
s! BAFFLE OPENING
`
°
com
a 50.0'
�y
q
f
�� RAMP O CHAMBER 2
16X
397.25 397.50
0
0
42S'
- 1.70Xa,
x
E3A FLE OPENING
v
0
oo
gx
ro
' 50' RAMP O 16XCHAAIBER 1
397.25
v et
ro
n
a $
o
D
n
n
„r 39&00
—+
s
�
A
'��
RACK
357-% 7.50
�0
aq
15
DRUM RINSE DOWN AREA
X
g
FUEL STORAGE
xZ
--y
wz
!
! B
4' WEIR OPD
•
B
rn
A
o
flu
4' WEIR OPENING
BOLLARD (TYP
o$
a
A
SEGMENTAL OCK
RET WALL
", N
00
N
o
A
O /�
a
A
A
��
g
F1
�1E1. CONTApMIW
.._....
-
vO1i
�
BO
(TYP.)
�
n
..- _.. .... -,
CID� ..:
w
.. _ . 97.85
1Z
WIDE CONCRETE G
o
"n
N
O O
397-25
397INSTALL
x39Z25
�c
WITH RAISED
OF W
P TO PREVENT MI NG
TEWATER/STORMW
g
A
�
0)
o
n
A
\
PROVIDE 5• SPACING
BOTT
\
INSTALL 12• WIDE CON ETE EDGE
ROW OF BLOCKS TO
PASSAGE OF
A
WITH RAISED LIP TO P MIXING
STORM WA
THROUGH WALL.
IN ST
24" WIDE CONCRETE EDGE
OF WASTEWATE STORMWATER
CONTRACTOR SHALL
GS DUTY
WITH
SED UP TO PREVENT MIXING
N
ON FRO
OpF OPEN NI
OF WASTEWATER/STORMWATER
KEEP AGGREG
FROM MIGRATING
O
ROUGH OPENING.
O
00
OWNER TO AP
PRIOR TO IN ST
OVAL GRATE SIZING
TION (24 X24- MIN)
i I
,
INP
1 '
J `\\���11
J .� �N l.r Nq
i
OVERFLOW FROM STORM EVENTS
GREATER THAN 25 YEAR-24 HR
WILL EXIT RECYCLE BASIN FROM
TOP OF RAMP
^T
O .• ESS '• 'r2
SEAL
26495 jc?
:H p`� "
••• \,` t( j `
A
rn
1 i
a HOW frdr
--------------------''' -------------------
-
Na
ReMm
Date
Wj
D*w tit
&*
EAGLE ROCK - PRISTINE WATER DRIVEPLAN,WITHERS
APEX WAKE COUNTY NORTH CAROUNA
WASTEWATER SITE/GRADING
RAVEN EL
ENGINEERS I PLANNERS I SURVEYORS
115 MacKenan Drive Cary, North Carolina 27511 tel: 919-469-3340 nw.withersramel.con License No. C-N32
shm No.
3
°-m&I ��►
cllerw4
Dryy
Job Na
2�ppgpp
t � : 11 r:• , �- •f
CONCRETE aiAMBER BOUYANCY CALCULATIONS - CLOSED LOOP RECYCLE SYSTEM
CONCRETE TOTo cAMBErtFLUMIE
AsOG�G�ATE I-FIANORAAM
CHAMBER 1
E1- 397.
2.5x MIN SLOPE
INTO CHAMBER TANK
10'-•tl'
SWICTURAL DESIGN BY OTHERS
CHAMBER 2
E.
CROSS-SECTION C-C NOSTRUCTURAL DESIGN s`Y OTHERS
CHAMBER 3
CROSS-SECTION D-D
Dubin yin
Scde AS SHOWN
Dawn 91
ftFm
DMe
,mm
Cbedoed M
Job Na
DW
2t211vm
1319
EL- 397
MIN SLOPE
CHAMBER TANK 1
1 o-o'
NOTESTRUCTURAL DESIGN BY OTHERS
DESIGN ASSUMPTIONS
* WATER TABLE AT 393.00
s CHAMBERS 1, 2, & 3 WITH WASTEWATER TO ELEV. 395.25
* SOIL BEARING PRESSURE NEGLECTED
(WEIGHT OF STRUCTURE) + (WEIGHT OF WASTEWATER)
(UPLIFT FORCE)
WEIGHT OF STRUCTURE
WEIGHT OF CONCRETE IN CHAMBERS
WALLS - NORTH
= 46'L X 10.5'H X 1' W X 150 LB/FT3 X 1 WALL
= 31.5'L X 9.75'H X 1' W X 150 LB/FT3X 1 WALL
WEIGHT OF WATER DISPLACED BY CONCRETE CHAMBERS (UP TO EL 393.00)
= 4'L X 8'H X 1' W X 150 LB/FT'; X 1 WALL
CHAMBER 1
= 123,319 LBS
= 97.15 SF X
12.33' = 1,197.9 CF X 62.4 LB/CF
WALLS - EAST
= 151 X 10.5'H X 1' W X 150 LB/FT3
= 74,746 LBS
= 221 X 10'H X 1' W X 150 LB/FT3
CHAMBER 2
= 20'L X 9.25'H X 1' W X 150 LB/FT3
= 97.15 SF X
11.67' = 1,133.74 CF X 62.4 LB/CF
= 84,375 LBS
= 70,745 LBS
CHAMBER 3
WALLS -SOUTH
= 97.15 SF X
12.33' = 1.197.9 CF X 62.4 LB/CF
= 46,X 8 25'H X 1' W X 150 l.B/FT3X 1 WALL
= 74,746 LBS
= 56925 LBS
CHAMBER 4
WALLS -�
= 46.67 LF X
4.58 LF X 58 LF 12,397.4 CF X 62.4 LB/CF
= 343.27 FT2X 1'W X 150 L.B/FT3X 1 WALL
= 773,599 LBS
= 51,491 LBS
WALLS - INTERIOR BETWEEN CHAMBERS 1 &3
TOTAL =
993.837
= 194.45 FT2X 8'W X 150 LB/FT3 X 2 WALLS
= 38,890 LBS
WALLS - INTERIOR BETWEEN CHAMBERS 3&4
= 246.75 2Ff X 1'W X 150 LB/F'T3 X 1 WALL
= 37,013 LBS
ENTRANCE SLAB
= IO'L X 34.5'W X 8"D X 150 LB/FT-3
1,335,454 LBS
= 34'500 LBS
= 1.344 FACTOR OF SAFETY
93.837 LBS
FLOOR
- 82.51 X 58'W X 1 d' D X 150 LB/FT3
= 598,125 LBS
TOTAL = 1 024 638
WEIGHT OF WATER IN CHAMBERS 1, 2, do 3 (UP TO EL:- 395.25)
CHAMBER 1
= 150.94 SF X 1 IV X 62.4 LB/CF
= 103,605 LBS
CHAMBER 2
= 150.94 SF X 11'W X 62.4 LB/CF
= 103,605 LBS
CHAMBER 3
= 150.94 SF X 11'W X 62.4 LB/CF
= 103,605 LBS
CHAMBER 4
NOTE:
STRUCTURAL DOM BY OTHERS
CONCREM FLUME TT) CHAMBER I HAND RAIL
AGGREGATE HAND RAL
STORAGE
AREA
TOP WALL • 399.75
STOP WALL EL. V7.50
Req*W WaW Storage Am 9.7V
8.7s'
ss•-ar
CROSS-SECTION E-E
APEX WAKE COUNTY NORTH CAROUNA
EAGLE ROCK -PRISTINE WATER DRIVE
I AGGREGATE
BIN 3
4' WEIR
w
W
Li
ly
0
z
0
0
B
C
111
s -o•F,11
4' WEIR OPENING
2'X2'X6' CONCRETE BLOCK
AGGREGATE AGGREGATE BIN WALL
D BIN 4
NG 0 E ER 1
WEIR ING
IN WALL
CHAM ER 1 CHAM ER 2 CHAM ER 3
DING
METAL D RAILS
V,
bt
R
Cr
®
0
3
0_
I
a-
0
0
�
Y
z
LO
a:
I
I
I
1 r'-a'
11-O'
1 t'-or
Y
o:
CONCRETE E CE RAMP
I 1
B C D
WA r•1a
L
CONCRETE FLUME
CHAMBER 4
56' X 45'-2" X 6.75'
STORAGE CHAMBER
45'-r
OVERFLOW FROM STORM EVENTS
GREATER THAN 25 YEAR-24 HR
WILL EXIT RECYCLE BASIN
DESIGN CALCULATIONS
STORAGE VOLUME FROM 25-YR 24-HR STORM EVENT
TOTAL TREATED SURFACE AREA TO WASTEWATER RECYCLE SYSTEM:
25-YEAR 24 HOUR STORM DEPTH (IN):
TOTAL DESIGN STORM VOLUME TO BE CAPTURED:
STORAGE VOLUME FROM TRUCK WASHING
AVG NUMBER OF TRUCKS/DAY:
AVG GALLONS OF WATER USED PER TRUCK WASHDOWN:
TOTAL VOLUME FROM TRUCK WASHING:
STORAGE VOLUME FROM DRUM RINSE --OUT
AVG NUMBER OF TRUCKS/DAY:
AVG GALLONS OF WATER USED PER TRUCK WASHDOWN:
TOTAL VOLUME FROM TRUCK WASHING:
TRUCK
WASH RACKS
1
METAL HAND RAIL
acauE: r•a'
METAL HAND RAIL
HAND RAN.
1
E
37,110 SF; 0.85 AC
5.84 IN (0.49')
18,184 CF; 136,026 GAL
5 TRUCKS AT 3 LOADS/DAY
15 GALLONS
225 GAL/DAY
15 TRUCKS AT 0.5 CY/TRUCK
15 GALLONS
7.5 CY; 56 GAL/DAY
TOTAL VOLUME REQUIRED TO BE CAPTURED: 225 GAL + 56 GAL + 136,026 GAL = 136,307 GAL; 18,222 CF
VOLUME PROVIDED: CHAMBER 4 (56' X 45' X 6.75') = 17,010 CF
AREA ABOVE NORMAL WSEL IN CHAMBERS 1-3 (60.25 SF X 32'-6') = 1,958 CF
TOTAL VOLUME PROVIDED: 18,968 CF; 141,891 GAL
12" FREEBOARD PROVIDED ABOVE REQUIRED STORAGE VOLUME: 86' x 45' x 1' = 3,870 CF; 28,950 GAL
MAXIMUM STORAGE VOLUME WITHIN RECYCLE SYSTEM: 28,950 GAL + 141,891 GAL = 170,841 GAL
PROJECT SUMMARY
A RECYCLE FACILITY HAS BEEN DESIGNED TO CAPTURE THE 25YR-24HR STORM EVENT PLUS TRUCK WASHING AND DRUM
RINSE -OUT WITHOUT DISCHARGE TO SURFACE WATERS. THIS DESIGN CONSISTS OF ISOLATING THE INDUSTRIAL OPERATIONS
FROM THE NON -INDUSTRIAL AREAS. SURFACE STORMWATER/WASTEWATER IS COLLECTED VIA CONCRETE SURFACE FLUMES
AND DISCHARGES INTO A SERIES OF CONCRETE CHAMBERS DESIGNED TO SETTLE SEDIMENT AND PROVIDE STORAGE AS
REQUIRED TO MEET NCDWQ REQUIREMENTS. RECYCLE/PROCESS WATER FROM THE LAST CHAMBER WILL BE PUMPED
OUT AND RE -USED TO IRRIGATE AND HYDRATE AGGREGATE STORAGE AREAS AND RE -USED IN PROCESSED BATCH
CONCRETE. A NON -DISCHARGE RECYCLE PERMIT WILL BE SOUGHT FROM NCDENR-DWQ.
REFERENCES:
* NOAA ATLAS 14 VOLUME 2, VERSION 3, RALEIGH DURHAM PRECIPITATION FREQUENCY ESTIMATE CHART
WASTEWATER RECYCLE SYSTEM DESIGN
WITHERS �`�
&_RAVENEL
ENGINEERS I PLANNERS I SURVEYORS 4
115 Mad(enan lhive Cary, North Carolina 27511 td: 919-469-3340 www.wlttlersrTrvenel.com License No. C-0832
11'1 ,�' t'� • ', I (' d 1j'
� ff M ,
TYPICAL CONCRETE BLOCK WALL DETAIL
AROUND AGGREGATE STORAGE BINS
1/2- = l'-Off
2'x2'x6' V—INTERLOCK
:"t
SOLID CONCRETE BLOCK
8' HIGH
.. .2j,
�.4
2#
F.
4_
HEAVY DUTY CONCRETE SLAB
A -A A
4 SEE PLAN FOR DESIGN
q 4'
COMPACTED SUBGRADE
FLOW FLOW
STORMWATER WASTEWATER
RAISED UP
Zy Ix MIN SLOPE sjoPE
CONTRACTION JOINTS SPACED AT 15'-(r O.C.
TYPICAL CROSS-SECTION A -A (SHEET 3)
RAISED CONCRETE I EDGE Iff Y H&V
SOLID CONCRETE BLOCK WALL % .S.4' S Co"wr S T43lock 4-Smaighl 3' StWght
aly (6) ay(2) Oty(2) City(6)
AGGREGATE PI
TYPICAL CONCRETE BLOCK
STACKING PATTERN
NTS
PERMANENT AGGREGATE STORAGE BIN DETAIL
TYPICAL PERSPECTIVE VIEW
NTS
FLOW FLOW a
STORMWATM RAISED UP WASHWATER
, 2 1 SLOPE X MIN SLOPE
"27
CONTRACTION JOINTS SPACED AT 15'-0' O.C.
TYPICAL CROSS-SECTION B-B (SHEET 3)
RAISED CONCRETE EDGE 'r = f H&V
2
%
.
--CONCRM:�.:::'V-_
---BLOCK
CONCRETE.:'
BLOCK
)CK
:.WALL
CONCRETE SMALL 7
3-Wd.
STREN
mi
FLOW SUMMARYA.
DA: 8685 SF; 0.20 AC "'IF31 E3 I E3 I FE3 I E3 I E� I FE3 1 F9 1 F':l I F4 I 9= 1 qAjq4fiLC,0MPACTED SUBGRADE-
C: 0.90 I�"
TC: 5 MIN TYPICAL CROSS-SECTION C*C (SHEET 3) CONTRACTION JOINTS SPACED AT 15'-U' O.C.
125: 7.76 IN/HR
025 MAX: 1.40 CFS
NORMAL DEPTH: 0.25 FT CONCRETE FLUME 1' = f H&V
UA: Z-10JU Jr; U.0,) AU
C: 0.90
TC: 5 MIN
125: 7.76 IN/HR
Q25 MAX: 4.40 CFS
NORMAL DEPTH: 0.39 FT
TYPICAL CROSS-SECTION D-D (SHEET 3)
CONCRETE FLUME
CONTRACTION JOINTS SPACED AT 15'-0r O.C.
1'= Y H&V
CONCRETE BLOCK WALL DETAIL
1/47 = l'—U'
TOP WALL EL:- 399.00
1.75'
TOP WALL EL- 398.25
FLOW SUMMARYl'."'...1-
DA: 29511 SF; 0.68 AC
C: 0.90
5 MIN
'C
25: 7.76 IN/HR w
BE
-A. �5Q25 MAX: 4.75 CFS
WALL
-4 NORMAL DEPTH: f 0.30 F--
TOP WEIR EL-39 7.25
V.-
z
ECYCLE CHAMBER 1
10,
TYPICAL
CROSS-SECTION F-F (SHEET 3)
ENTRANCE WEIR
EL395.25
T H&V
PROVIDE Cr SPACING BETWEEN BOTTOM
ROW OF BLOCKS TO ALLOW PASSAGE OF
CONCRETE BLOCK WALL STORMWATER THROUGH WALL.
CONTRACTOR SHALL INSTALL HEAVY DUTY
GRATE ON FRONT OF OPENINGS TO
THROUGH OPENING.P AGGREGATE FROM MIGRATING
OWNER TO APPROVAL GWSIZINGPRIOR TO INSTALLATION (24 X24 MIN)
EL-399.75
CONTRACTION JOINTS SPACED AT 15'-0r O.C. FLOW FL_OW
ve
Intl
- Z -
7%
_k•t.yi•CONC RETE
CONCRETE SHALL 6E:;!'
RECYCLE
CHAMBER
3,000 MIN COI
WALL
APRESSIVE-.7. ..... .
STRENGTH.
C. COMPACTED RtjRnRAnF
4r
com GRAD
FLOW SUMMARY
4L
DA: 13,164 SF 0.30 AC
C: 0.90
% TC: 5 MIN
TYPICAL CROSS-SECTION E-E (SHEET 3) 125: 7.76 IN/
025 MAX: 2.1 CFS
NORMAL DEPTH: 0.27 FT
CONCRETE FLUME 1' 1' H&V
-o C A,90
.00fEssx, 6% 1,
Z 0
-Z po W-%
Z SEAL
25495
%
Na
Revision
Dube
&j
Daow
vm
SC&
AS SHOWN
EAGLE ROCK PRISTINE WATER DRIVE
APEX WAKE COUNTY NORTH MOLINA
WASTEWATER RECYCLE SYSTEM DETAILS
WITHERS RAVEN EL
ENGINEERS I PLANNERS I SURVEYORS
115 Madenan Ikive Cary, North Carolina 27511 tel: 919-469-3340 www.withersmvenel.com License No. C-0832
AWN&
5
ftm &I
ffim
ma
vmm
DW
Job Na
2mwm.
i 7-7., 7-.7 r: 7:
j
TOP /WALL
ELEV. = 397.50'
CONTINUOUS ADHESIVE
TYPE WATERSTOP
(3/4" x 1" GREENSTREAK SWELLSTOP
OR EQUIVALENT) - PROVIDE 212"
Ulm rnNr%0M= rnvco
0
#6 @ V-0" O.C. EA. WAY, _
TOP & BOTT.
T
1-12" x 5"
FORMED KEYWAY
#6 @ V-0" O.C. EA. WAY,
TOP & BOTT.
if-n"
GUARDRAIL - SEE
CIVIL DWGS.
#5 VERT. @ 1'-0" O.C.,
EA- FACE
#4 HORIZ. @ V-0" O.C.,
EA. FACE
DOWEL AT EA. VERT. - MATCH
SIZE & SEE SCHED. FOR LAP AT
TOP / HOOK AT BOTT. (TYP.)
WATERSTOP-SEE
PLAN NOTES
3 SECTION
S1 3/4" = 1'-0"
PRECAST CONCRETE BIN
BLOCKS BY OTHERS (TYP.)
- SEE CIVIL DWGS. FOR
BLOCK SPACING &
GRATING REQUIREMENTS
`
SLAB ON GRADE -
- J
SEE CIVIL DWGS.
=
•,. '� •
4
io
(3) # 5 CONT. LONG.
# 5 @ 2'-0" O.C. TRANS.
�! r-o" .4
4 SECTION
1\,T� 3/4" = 1 1-012
TOP / SLAB
CONCRETE FLUME -
NSEE CIVIL DWGS.
8"
TOP / WALL
ELEV. = 396.25' t - w 1
#5 VERT. @ V-W O.C.
•- :.
DOWEL AT EA. VERT. - MATCH
SIZE & SEE SCHED. FOR LAP AT
TOP / HOOK AT BOTT. (TYP.) •
TOP / SLAB
SLOPES 49
#6 @ 1'-0" O.C. EA. WAY,
TOP & BOTT.
2 SECTION
S1 3/4" = 1'-0"
T-0" 58'-0"
4
S1
I
I
I
I
I
I
1
I
I
s,
PRECAST CONCRETE BIN
I
I
BLOCKS BY OTHERS (TYP.)
- SEE CIVIL DWGS. FOR
BLOCK SPACING &
(
w
GRATING REQUIREMENTS
I
LL
1120
I
LU5
UU
I
I
c°� v
4
s,
I
I
I
(
I
�
II
S,
/ WALL
SEE PLAN
#5 VERT. @ 1'40" O.C_,
EA. FACE
; WW
GUARDRAIL - SEE
CIVIL DWGS.
• #4 HORIZ. @ 1'-0" O.C.,
EA. FACE
DOWEL
O�§
SIZE & SEE SCHED. FOR LAP AT
TOP HOOK AT BOTT. (TYP.)
WATERSTOP - SEE PLAN
NOTES
\
A
(VARIES Q RAMP
aSECTION
)U4
T.O.W. = +399.25' T.O.W. _ +398.50'
19' 0
4
T.O_W_ _ +399.76 TOP / SLAB = +389.25'
�— T.O.W. = +399.75' T.O. W- _ + 997.50' p1
* S,
TOP / SLAB = +389.25'
- T.O.W. = +399.75' T.O.W. _ +397.50'
1
s,
4'-0" WEIR OPENING
c
ELEV. = +395.25' T_O.W. _ +397.50'
`-
•-r a :A. - - - : ► . . Yam• v t, •.ti- -+.:
774.
TOP / RAMP
" i : = :: ; : <-•
�---- RAMP DOWN = +397.25'
4'-0" WEIR OPENING
T.O.W.=+396.25'
- T.O.W.
_ +399.00 ELEV. _ +395.25
: ;., ..
Co
TOP /SLAB I 13'-0"
tom—
�• ^•: -
_ +389.25' RAMP DOWN CONTROL
• ' ' ' . ' .:-"
`r. - • •
-
9
JOINT
: ~•; :.' -•=.
4'-0" WEIR OPENING
ELEV. _ +395.25' T.O.W. _ +396.25'
:. • - ::, s: `::
w• �•+
CONCRETE FLUME - 4'-0" WEIR OPENING :� •.° '�
SEE CIVIL DWC38. ELEV. ■ +387.26' RAMP DOWN
T.O.W. = T.O.W. _ : _ - -AA :
— — — — — — — — +398.50' +398.50'
4'-0" WEIR
T.O.W. _ +398.50' 10' 6'-0" -0"
4 I OPENING ELE\ 4
s1 = +397.25' N 4'-0" WEIR OPENING
ELEV. _ +396.90' 8" CONCRETE ENTRANCE
I SLAB W/ 6x6 - W1.4xW1.4
I 5T-0" WELDED WIRE REINFORCING
�
I
PRECAST CONCRETE
I BIN BLOCKS BY
OTHERS (TYP.)
I
I
I u
I
I
I
WASTEWATER RECYCLE SYSTEM FOUNDATION PLAN
1" = 10'
General Notes:
I. Foundations:
1. Foundation design is based on an allowable soil bearing pressure of 2000 PSF as stated in a subsurface exploration
report prepared by TM Engineering, Inc. dated August 14, 2012.
II. Structural Concrete:
1. Concrete shall have a minimum 28-day compressive strength of 3000 psi, unless noted otherwise.
2. Concrete shall be normal -weight, air entrained, and shall have a maximum unit weight of 145 pcf, unless noted
otherwise.
3. Reinforcing steel shall conform to ASTM A615, Gr60, including ties and stirrups.
4. Minimum concrete cover shall be as follows, unless noted otherwise:
a) Unformed surfaces in contact with the ground..............................................................................•-...-•__................. 3"
b) Formed surfaces exposed to earth or weather ............................ - 2"
c) Formed surfaces not exposed to earth or weather...........................................................................................
1117
5. Plumbing, mechanical, and electrical (PME) drawings shall be referred to for drains, sleeves, outlet boxes, conduit,
anchors, etc. The various trades arp responsible for placing their respective items.
III. Miscellaneous:
1. Structural drawings are intended to be used with architectural and PME drawings. Contractor is responsible for
coordinating such requirements into their shop drawings and work.
2. No opening shall be made in any structural member without written approval of the Structural -Engineer -of -Record.
3. No change in size or dimension of structural members shall be made without written approval of the
Structural -Engineer -of -Record.
4. Openings V-4" and less on a side are generally not shown on the structural drawings. Refer to architectural and PME
drawings for such openings.
5. The contractor is responsible for limiting the amount of construction loads applied to the structural framing. Construction
loads shall not exceed the design capacity of the framing at the time the loads are applied.
6. Fire proofing methods and materials for structural members are not shown on structural drawings, unless noted
otherwise. Refer to architectural drawings for fire proofing methods and materials.
7. Do not scale these drawings; use dimensions.
LAP SPLICE AND 900 HOOK SCHEDULE
BAR
SIZE
LAP (In-)
90' HOOK (in.)
TOP BARS'
OTHER BARS
#3
22
17
6
#4
29
22
8
#5
36
28
10
#6
43
33
12
#7
63
48
14
"'Top Bare" rotors to horizontal reinforcing placed with more
than 12 in. fresh concrete cast below -the reinWming.
REINFORCING BAR LAP & HOOK SCHEDULE
FOR CAST -IN -PLACE CONCRETE
LAP -SEE
crw;:nl a r=
90o Ur%r%V
SEE
CONTINUO'
REINFORCI
AT CORNER
AT INTERSECTION
Note: Where throe or more bars occcu', the
center bars shall be treated as inner face
reinforcement
PLACEMENT OF CONTINUOUS REINFORCING FOR
BOND BEAMS, FOOTINGS AND CONCRETE WALLS
Foundation Plan Notes:
•cR� 1. All slabs -on grade shall bear on 4" compacted, porous fill.
2. See sections for concrete reinforcement
3. Provide continuous 6"x12" ribbed flat waterstop where indicated on drawings.
4. See Typical Construction Details on Sheet S1.
5. See General Notes on Sheet S1.
d
m
O
•
C
SEAT_
CAI?9 f,,
S, •
Ar.
_ SEAL
032586 ? _
,J , •GINS G��p���,`•
G.r A003.01.13
+j U
J
� / w
U Q
C
Ct p L.
U
_j
frr� CID
p
Co
U
a)
z
n�
+W "C
.7
w
X
�LuCL
SHM Tm.E
Foundation Plan, Sections
& General Notes
DRAwN
LGG
REVIEWED KLN
DATE
03.01.13
REVISIONS
SHEET
S1