Loading...
HomeMy WebLinkAboutNCG140403_COMPLETE FILE - HISTORICAL_20110921STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. DOC TYPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ ��0�� � � a � YYYYMMDD North Carolina Beverly Eaves Perdue Governor Mr. Wilbur Dees, PE 2927 Middlesex Rd. Fayetteville, NC 28306 Dear Mr. Dees: ,i; NCDEAR Department of Environment and Natural Resources Division of Water Quality Coleen H. Sullins Director September 21, 2011 Dee Freeman Secretary Subject: Return of Authorization to Construct Request ATC for COC No. NCG140403 OIB Ready Mixed Concrete Brunswick County This letter is in reference to your ATC application received on July 12, 2011, for the construction and operation of the subject wastewater treatment facilities. The Division of Water Quality is returning your application in accordance with recent changes in legislation. Session Law 2011-394, which became effective July 1, 2011, no longer requires a permit to "enter into a contract for the construction, installation, or alteration of any treatment works or disposal system or to construct, install, or alter any treatment works or disposal system within the State when the system's or work's principle function is to conduct, treat, equalize, neutralize, stabilize, recycle, or dispose of industrial waste or sewage from an industrial facility and the discharge of the industrial waste or sewage is authorized under a permit issued for the discharge of the industrial waste or sewage into the waters of the State. Notwithstanding the .above, the permit issued for the discharge may be modified if required by federal regulation." Based upon our review of your application, the subject project does not require an Authorization to Construct. Please note that based on a cursory review, the proposed system design does not appear to capture the 25-yr, 24-hr storm without discharging; and then recycled. Please be advised that these legislative changes do not relieve you of any other condition or requirement of your NPDES permit and that the construction and/or operation of wastewater collection, treatment, and/or disposal facilities without a valid permit is a violation of North Carolina General Statute §143-215.1 and may subject the owner/operator to appropriate enforcement actions in accordance with North Carolina General Statute §143-215.6A-6C. Civil penalties of up to $25,000 per day per violation may be assessed for failure to secure a permit required by North Carolina General Statute §143-215.1. If you have any questions concerning this matter, please contact Robert Patterson at telephone number (919) 807-6375, or at robert.patterson@ncdenr.gov. '.letlands and Stormwater Blanch ; 617 Mail Service Center, Ralegh, North Carolina 27699-1617 oration: 12 N. Salisbury F. Rsleig' North Carolina 2-604 hone: 9 q-807-63001 FA> 919-807 � 494 L Customw ;ei •+ice: 1 877-623-6748 lnternet:w.-m cwaterquality.org A.ntqual0,eoriunilylAiirmx, :Ar.@onF: Moyer One N(irthCarolina )Ukmll1y Mr. Wilbur Dees, PE NCC140403 ATC - C;B Ready Mixed Concrete Sep! -amber 21, 2011 Sincerely, Robert D. Patterson, PE Stormwater Permitting Unit cc: Mr. Daniel Simmons - OIB Ready Mixed Concrete, LLC Wilmington Regional Office - Linda Willis SPU Files Page 2 of 2 lip NC®ENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director August 17, 2011 Mr. Wilbur Dees, PE 2927 Middlesex Rd. Fayetteville, NC 28306 Subject:Additional Information Request ATC for COC No. NCG140403 0113 Ready Mixed Concrete Brunswick County Dear Mr. Dees; Dee Freeman Secretary Additional information for Authorization to Construct a wastewater treatment system was received by the Stormwater Permitting Unit.via email on August 9, 2011. However, a review of that additional information showed that the application is still incomplete. Before the ATC can finish being processed, please provide information regarding the following: 1. You stated in your letter dated August 9, 2011, that "We will construct basin no. 6 to retain the additional storm waters between the 25 year and the 10 year storm events." However, the calculations provided in the original ATC request only show that the 10-yr storm will be captured (plus 1' of freeboard). Please provide calculations to substantiate your above statement. Note that if you do capture. and recycle the 25-yr storm (plus 1' of freeboard), then analytical monitoring is no longer required. A water balance must be provided to show that it can be reused within approximately 5 days. 2. If the 25-yr storm (plus 1' of freeboard) is not captured and recycled, then you must provide settling calculations to show that the discharge will be able to meet permit limits. The data from a single event, a narrative, and a promise to do after construction testing to get empirical data is not acceptable to proving that these limits will be met prior to construction. If you have any questions concerning this matter, please contact Robert Patterson at telephone number (919) 807-6375, or at robert.patterson@ncdenr.gov. Sincerely, e6 /1] Robert D. Patterson, PE Stormwater Permitting Unit Wetiands and Stormwater Branch 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 one Location: 512 N. Salisbury St. Ralegh, North Carolina 27604 Nord 'Caro"a Phone: 919-807-63001 FAX 919-807-64941 Customer Service:1-877-623-6748 Internal: www.ncwaterquality.or9 - rfd An Equal Opportunity 1 Affirmative Action Employer Nw Mr. Wilbur Dees, PE NCG140403 ATC — OIB Ready Mixed Concrete August 17, 2013 cc: Mr. Daniel Simmons - OIB Ready Mixed Concrete, LLC Wilmington Regional Office - Linda Willis SPU Files Page 2 of 2 WILBUR E. DEES, P.E., P.L.S. CONSULTING ENGINEERING AND LAND . SURVEYING 2927 MIDDLESEX ROAD FAYETTEVILLE, N. C., 28306 PHONE 1 FAX (910) 425-1941 CELL (910) 624-4779 AUGUST 9, 2011 STORMWATER PERMITTING UNIT DIVISION OF WATER QUALITY 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 RE: OIB READY MIX CONCRETE, LLC PO BOX 6965 1581 LOBLOLLY LANE OCEAN ISLE BEACH, NORTH CAROLINA 28469 DEAR SIR: AUG 9 2011 a'NR • WATER QU411Y WETWO AND STOR1uIMlATS WAKH WITH REGUARDS TO YOUR LETTER DATED JULY 22, 2011, REQUESTING ADDITIONAL INFORMATION FOR THE ATC FOR COC NO. NCG140403, OIB READY MIXED CONCRETE, BRUNSWICK COUNTY, WE BELIEVE THAT ANY SETTLING COMPUTATIONS FURNISHED, USING THE STOKES LAW FORMULA, WOULD BE DISTORTED. IN A STORM EVENT THE CONCRETE PLANT WOULD BE SHUT DOWN. THERE WOULD BE NO WASTE WATER CREATED BY THE PLANT OPERATION FOR THE STORM DURATION. THE WASTE WATER CREATED WOULD COME FROM THE STOCK PILES AND THE PLANT WASH DOWN SOURCES ONLY. DURING THE STORM DURATION THE POLLUTANTS FROM THESE TWO SOURCES WOULD BECOME LESS AND LESS CONCENTRATED. THE STORM WATERS WOULD BE CLEANING THESE TWO SOURCES AS THE STORM WOULD PROGRESS. WE THINK BY TESTING THE BASINS, AS THEY ARE CONSTRUCTED, AND DURING LESSER RAINFALL EVENTS, WE CAN ESTABLISH AN EMPIRICLE "SETTLING TIME" THAT IS MORE REALISTIC. WE WILL CONSTRUCT BASIN NO. 6 TO RETAIN THE ADDITIONAL STORM WATERS BETWEEN THE 25 YEAR AND THE 10 YEAR STORM EVENTS. BASED UPON THE STORM DATA PREVIOUSLY SUBMITTED THE 10 YEAR, 24,HOUR EVENTf;WILL PRODUCE APPROXIMATELY 7 INCHES OF RAINf=A[C.' THE'25, YEAR, 24 HOUR EVENT WILL PRODUCE APPROXIMATELY 8.5 INCHES OF RAINFALL PLEASE,ADVISE ANY ADDITIONAL INFORMATION THAT YOU MIGHT NEED. SINCERELY YOURS, WILBUR E. DEES, P.E., P.L.S. Au 0� NCDENR North Carolina Department of Environment and Beverly Eaves Perdue Governor Mr. Wilbur Dees, PE 2927-Middlesex Rd. Fayetteville, NC 28306 Dear Mr. Dees: Division of Water Quality Coleen H. Sullins Director July 22, 2011 Natural Resources Subject: Additional Information Request ATC for COC No. NCG140403 OIB Ready Mixed Concrete Brunswick County Dee Freeman Secretary Your facility's application for Authorization to Construct a wastewater treatment system was received by the Stormwater Permitting Unit on July 12, 2011. However, a review of the application package showed that the application is incomplete. Betbre the ATC can finish being processed, please provide information regarding the following: Please provide settling calculations to show that the discharge will be ab?e to meet permit limits. The data from a single event and narrative is not acceptable to proving that these limits will be met. The narrative states that wastewater will be sampled before it is released, but the system is only sized for the 10-yr, 24-hr rain event. So, rain events in excess of the 10-yr, 24- hr event will be able to discharge, and not allow for sampling prior to release. Another alternative to providing settling calculations is to size the system to hold the 25-hr, 24-hr rain event plus 1 foot of freeboard. If you have any questions concerning this matter, please contact Robert Patterson at telephone number (919) 807-6375, or at robert.patterson@ncdenr.gov. Sincerely, Robert D. Patterson, PE Stormwater Permitting Unit cc: Mr. Daniel Simmons — OIB Ready Mixed Concrete, LLC Wilmington Regional Office — Linda Willis SPU Files Wetlands and Stormwater Branch 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 91M07-64941 Customer Service: 1-877-623-6748 fitemet: www.ncwaterquality,org An Equal Opportunity\AiiirmativeAcbcn Employer One NorthCarohna ;Vatura!!y WILBUR E. DEES, P.E., P.L.S. CONSULTING ENGINEERING AND LAND SURVEYING 2927 MIDDLESEX ROAD FAYETTEVILLE, N. C., 28306 PHONE / FAX (910) 425-1941 CELL (910) 6244779 JUNE 24, 2011 STORMWATER PERMITTING UNIT DIVISION OF WATER QUALITY 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 RE: OIB READY MIX CONCRETE, LLC PO BOX 6965 1581 LOBLOLLY LANE OCEAN ISLE BEACH, NORTH CAROLINA 28469 DEAR SIR: OIB READY MIX CONCRETE, LLC, RESPECTFULLY REQUEST AN AUTHORIZATION TO CONSTRUCT (ATC) PERMIT TO UPGRADE ITS EXISTING FACILITIES TO PREVENT FUTURE WASTEWATER DISCHARGE FROM ITS PROPERTY BY INSTALLING THE RECYCLE SYSTEM AS SHOWN ON SHEET NO. W-3 OF THE ATTACHED DRAWINGS. THE FOLLOWING ARE ITEMS OF WORK THAT NEEDS TO BE CONSTRUCTED AT THE PLANT SITE. 1- RECONFIGURE THE EXISTING STOCKPILES TO DRAIN WESTWARD TO THE NEW HALF ROUND PIPE AS SHOWN ON DRAWING SHEET W-3 WHICH IS ENCLOSED HEREWITH. 2- INSTALL NEW 15 INCH HALF ROUND PIPE PARALLEL TO THE WESTERN PROPERTY LINE AS SHOWN ON DRAWING SHEET W-3. THE HALF ROUND PIPE SHALL BE CORRUGATED PLASTIC. �- A-TC - 5 k&4 Vt,� 61t� p,jp3 ,off. wfw4ck -6 3- INSTALL THE NEW HOLDING BASINS AND DETENSION BASIN AS SHOWN ON DRAWING SHEET W-3. 4- INSTALL THE OVERHEAD HOLDING TANK AND PUMP TO PROVIDE RECYCLED WATERS FROM THE HOLDING BASINS TO WASH TRUCKS AND MIXER DRUMS AS SHOWN ON DRAWING SHEET W-3. 5- RELOCATE EXISTING FUELING FACILITIES TO THE SOUTHWEST CORNER OF THE PROPERTY AS SHOWN ON DRAWING SHEET W-3. 6- REGRADE THE AREA WHERE THE MIXER TRUCKS ARE BATCHED SO ANY "SPILL -OVER WATER" CAN BE DISCHARGED INTO HOLDING BASIN #1 AS SHOWN ON DRAWING SHEET W-3 7- INSTALL NEW RIPRAP, SILT FENCE, HOLDING AREA AND ROCK DAM AT THE NORTHEAST CORNER OF THE PROPERTY TO PREVENT EROSION. 8- INSTALL NEW FORTANS PH CONTROL AND MONITORING SYSTEM, MODEL 5000S. 9- REGRADE PROPERTY TO INSURE THAT THE EXISTING IMPERVIOUS AREAS ARE KEPT CLEAN AND THAT THE EXISTING NATURAL DRAINAGE IS MAINTAINED. THE ABOVE ITEMS OF WORK CAN BEGIN WITHIN 10 WORKING DAYS AFTER THE ATC PERMIT IS RECEIVED. ALL WORK AND TESTING CAN BE COMPLETED WITHIN 120 WORKING DAYS. SINCERELY YOURS, VRloof E•p ' N f EAL 9� WILBUR E. S, P.E., P. *; 29594 • r yQ••�GII�'•��� CAO:nI " AUTHORIZATION TO CONSTRUCT APPLICATION NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM APPLICATION FOR COVERAGE UNDER GENERAL PERMIT NCG140000 FOR OIB READY MIX CONCRETE, LLC PO BOX 6965 1581 LOBLOLLY LANE OCEAN ISLE BEACH, NORTH CAROLINA 28469 6/24/2011 PREPARED BY: WILBUR E. DEES, P.E., P.L.S. 2927 MIDDLESEX ROAD FAYETTEVILLE, NORTH CAROLINA 28306 WILBUR E. DEES, P.E., P.L.S. CONSULTING ENGINEERING AND LAND SURVEYING 2927 MIDDLESEX ROAD FAYETTEVILLE, N. C., 28306 PHONE I FAX (910) 425-1941 CELL (910) 624-4779 TABLE OF CONTENTS FOR "AUTHORIZATION TO CONSTRUCT" APPLICATION COVER SHEET TABLE OF CONTENTS NCDENR APPLICATION SHEETS 1-5 EXHIBIT I - DIRECTIONS TO PLANT SITE EXHIBIT II - MERITECH, INC - II ANALYSIS OF SAMPLES EXHIBIT III - ENVIRONMENTAL CHEMIST, INC. DATA EXHIBIT IV - FORTRANS PH CONTROL AND MONITORING SYSTEM EXHIBIT V - PRECIPITATION CHART EXHIBIT VI - CHART OF VALUES FOR RUNOFF COEFFICIENTS EXHIBIT VII - LIMITED LIABILITY COMPANY INFORMATION (2 SHEETS) EXHIBIT VIII - TYPICAL CONCRETE MIX DESIGN EXHIBIT IX -AGENT DESIGNATION FACILITY LOCATION SHEET BRUNSWICK COUNTY MAP PLANT NARRATIVE - 3 SHEETS OPERATIOS NARRATIVE - 2 SHEETS DRAWING SHEET W-1 DRAWING SHEET W-2 DRAWING SHEET W-3 DRAWING SHEET W-4 DRAWING SHEET W-5 DRAWING SHEET W-6 AIFA Division of Water Quality / Surface Water Protection NCDENRNational Pollutant Discharge EIimination System rXVRWWl.`R Nay IEamv. ib"-.W443 NCG140000 NOTICE OF INTENT National Pollutant Discharge Elimination System application for coverage under G NCG140000: STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with acti SIC (Standard industrial Classification) Code - 3273 Ready Mixed G.,, luf GLG For new plant sites that will discharge or recycle process wastewater (even if commingled with stormwater): This NOI is also an APPLICATION FOR Authorization to Construct (ATC) wastewater treatment facilities. ATC requests must be submitted at least 90 days prior to construction'. For xisplant sites discharging or recycling process wastewater (even if commingled with stormwater): This NO] is also an APPLICATION FOR Authorization'to continue to operate wastewater treatment facilities in place. Construction, modification, or installation of any new treatment components at an existing site requires an ATC. Treatment facilities used to treat or recycle process wastewater (including stormwater BMP structures treating process wastewater flows commingled with stormwater) require an ATC prior to construction per 15A NCAC 211.0138. The authorization to construct or continue to operate will be issued at the same time as the Certificate of Coverage (COC) for the NCG 14 permit. Design of treatment facilities must comply with requirements of 15A NCAC 2H .0138 & .0139. For questions, please contact the DWO Regional Office for your area. (Seepage 5) (Please print or type) 1) Mailing address of owner/operator (address to which all permit correspondence will be mailed): Name Street Address City Telephone No, 2) Location of facility producing discharge: Facility Name Facility Contact Street Address City County Telephone No. Page 1 at 5 . 'As per 15A NCAC 2H .0106 2Unless treatment facilities are designed, constructed, and put into Operation by employees internal to the company who are qualified to perform such work for their respective companies in accordance with General Statutes, 89C-25 (7), plans and specifications must be signed and seated by a P.E. SWU-229-071408 Last revised 7114/08 NCG140000 N.O.I. 3) Physical location information: Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). __Z; i- Z (A copy of a county map or USES quad sheet with facility clearly located on the map is a required part of this application.) 4) Latitude 2_ '� % ' Longitude A - /�(deg, min, sec) 5) This NPDES Permit Application applies to which of the following: ❑ New or Proposed Facility Date operation is to begin X Existing 6) Standard Industrial Classification: Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code: 7) Provide a brief description of the types of industrial activities and products produced at this facility: (Include a site diagram showing the process areas present at this facility.) 8) Discharge points / Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater and/or wastewater from the property? � �. ' 1 /�- ; rl _ _el,46E 4�� s What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater and/or wastewater discharges end up in? If the site stormwater discharges to a separate storm sewer system, sewer system (e.g. City of Raleigh municipal storm sewer). / Receiving water classification (if known): the operator of the separate storm Note: Discharge of process wastewater to receiving waters classified as WS-II to WS-V or SA must be approved by the N.C. Dept. of Environmental Health. If DEH does not approve, coverage under NCG140000 cannot be granted. No new discharges of process wastewater are permitted in receiving waters classified as WS-I or freshwater ORW. 9) Does this facility have any other NPDES permits? X No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: 10) Does this facility have any Non -Discharge permits (ex: recycle permits)? ><No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 11) Does this facility employ any best management practices for stormwater control? ❑ No Page 2 of 5 SWU-229-071408 Last revised 711412008 NCG140000 N.O.I. 12) Does this facility have a Stormwater Pollution Prevention Plan? ANo ❑ Yes If yes, when was it implemented? 13) Are vehicle maintenance activities occurring or planned at this facility? XNo ❑ Yes Wastewater Treatment Design Information 14) Are discharges occurring or planned from any of the following process wastewater generating activities? Vehicle and equipment cleaning XYes ❑ No Wetting of raw material stockpiles AYes ❑ No Mixing drum cleaning Yes ❑ No If yes to any of the above, please describe the type of process used to treat and/or recycle the process wastewater./.S X�Sj� W, ,e / To, �' � "�ke C-/ /29 ': �- � f< V-1—A For a sufficient application, you must provide design specifics e. design volume retention time, surface aPp Y p g p ( 9-, 9 area, etc.) and calculations to demonstrate compliance with permit effluent limits (pH — 6-9 SU, Total Suspended Solids (TSS) — 30 mg/l, and Settleable Solids (SS) — 5 mill.) [Use separate sheet(s)]. If all these discharges are recycled, please refer to Question 15. For plants that recycle and/or d1schar4e Aracess wastewater: When applying for this permit, you are also applying for an authorization to construct (new treatment facilities) or authorization to continue to operate (existing treatment facilities) as part of the NOL For new sites, you must submit three -(3) sets of design plans and specifications with this application and provide supporting calculations that predict compliance of final discharge with permit limits. For existing sites, applicants should submit three (3) sets of plans and specs for facilities as -built and provide as many design details as possible, or submit a detailed diagram of treatment systems in place that includes information such as tank volumes, dimensions, retention time, piping, settling basin details, etc. Please note: If new treatment systems are planned for an existing site, an ATC will be required prior to construction of those facilities. Plans/specs/calculations prepared by a P.E. and the request for an ATC may be submitted with this NOI, or separately at a later date. DWO may request the status of your plans for requesting an ATC upon issuance of the COC. 15) Does the facility use or plan to use a recycle system? ❑ No X.Yes If yes, what size storm event is the system designed to hold before overflowing? (for example, 10-yr, 24-hr) ,%57 year, 24-hr rainfall event For a recycle system (regardless of when it overflows}, please provide plans, calculations, and design specifics (e.g., throughput assumptions/water balance, design volume, retention time, surface area, amount of freeboard in design storm event, etc.). [Use separate sheet(s)]. VLFor a sufficient application, the information must demonstrate compliance of final discharge with permit --! effluent limits (pH — 6-9 SU, Total Suspended Solids (TSS) -- 30 mg/I, and Settleable Solids (SS) -- 5 ml(l), or must demonstrate that the recycle system has sufficient capacity to contain runoff from a 25-year, 24-hr rainfall event plus one foot of freeboard under design operating conditions. Page 3 of 5 SWU-229-071408 Last revised 7/14/2008 NCG140000 N.O.I. 16) Are wastewater treatment facilities (including recycle systems) planned in the 100-year flood plain? A No ❑ Yes If so, include information to demonstrate protection from flooding. (Minimum design. requirements for treatment works include protection from the 100-year flood, per 15A NCAC 2H .0219.) 17) Hazardous Waste: a) is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? ANo ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? .kNo ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? A No - ❑ Yes d) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year. - Name of transport / disposal vendor: _ Vendor address: 18) Certification: North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Management) Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. 1 certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Nanle of Person Signing: Title:�� (Signature of Signed) Notice of Intent -must be accompanied by a check or money order for $100.00 made payable to: NCDENR Page 4 of 5 SWU-229-071408 Last revised 7/14/2008 NCG140000 N.O.I. Final Checklist This application will be returned as incomplete unless all of the following Items have been included: Check for $100 made payable to NCDENR. This completed application and all supporting documentation (including design details and calculations for treatment systems). } if an Erosion & Sedimentation Control (E&SC) Plan is required from Division of Land Resources (DLR) 1 or local designee: documentation verifying applicant has developed and submitted that Plan to the governing agency (required per 15A NCAC 02H .0138). For new sites (or sites that will install new treatment facilities): Three (3) copies of plans and 1 specifications for wastewater treatment facilities (including recycle -systems), signed and sealed by a Professional Engineer or qualified staff meeting requirements of G.S. 89C-25 (7), a�=t, For existing sites: three (3) copies of plans and specifications for wastewater treatment facilities (including 1 •SS recycle systems) as built, stamped and sealed by a Professional Engineer, or (only if plans not available) a detailed diagram of treatment systems in place that includes information such as tank volumes, dimensions, retention time, piping, settling basin details, etc. A site map showing, at a minimum, (existing or proposed): (a) outline of drainage areas, (b) stormwaterlwastewater treatment structures, (c) location of stormwater/wastewater outfalls (corresponding to which drainage areas), (d) runoff conveyance structures, (e) areas where materials are stored, (f) impervious areas, and (g) site property lines. >� A county map or USGS quad sheet with location of facility clearly marked.. Mail the entire package to: Stormwater Permitting Unit Division of Water Quality 1617 Mail Service'Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of an NPDES permit. For questions, please contact the DWO Regional Office for your area. DWQ Regional Office Contact information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office .........(919) 807-6300 Page 5 of 5 SWU-229-071408 Last revised 7/14/2008 WILBUR E. DEES, P.E., P.L.S. CONSULTING ENGINEERING AND LAND SURVEYING 2927 MIDDLESEX ROAD FAYETTEVILLE, N. C., 28306 PHONE 1 FAX (910) 425-1941 CELL (910) 624-4779 EXHIBIT NO. 1 DIRECTIONS TO OIB READY MIX CONCRETE, LLC 1581 LOBLOLLY LANE OCEAN ISLE BEACH, NORTH CAROLINA, 28469 FROM THE INTERSECTION OF NORTH CAROLINA ROADWAY NC 9041 NC 179 AND LOBLOLLY LANE, WITHIN THE CITY LIMITS OF OCEAN ISLE BEACH, NORTH CAROLINA, PROCEED NORTHWEST ON LOBLOLLY LANE THRU THE INTERSECTION OF EASTBROOK AVENUE SW 493'+1- TO THE ENTRANCE OF THE PROPERTY. SEE ATTACHED "GOOGLE VICINITY MAP" Address 1581 Loplolly Ln SW �o� e maps Ocean Isle Beach, NC 28469 Get Google Maps on your phone Totthewvd GMAPS"to466453 9 SAN �_ �aRraSa Rd Stiv z - c, � il• I91 N M z aA p [� 1 s ��ce;sn We a N ecat +n P1 5 v'J. 904 Fchrr�?. 179 1179 jica�l:rJ' S:! `k Rt.;ara ra,t e u - m APd u, 3 _ g Pigan Ave SW 1] �J �ayA F1eV ... ..• z � a Sn S�Vic�erLIIrad S%4- O 6• �' Wall ae Dr ' 9 H - 1 - r1 �plt 9 -- —� _' — -- 02011 Google - Map data 0201.1 Goagla, NIERITECH, INC - Il Laboratory Certification No. 602 4350 Sea Pines Drive Southport, NC 28461 Phone (914) 457-0289 fax. (91 d) 457-0289 Alternate Phone (910) 617-1353 OIB Ready Mix Concrete PO BOX 6965 1581 Loblolly L2ne Ocean Isle, NC 28469 corrected copy(sm) ATTN: Daniel Simmons Date of Report 219111 REPORT OF ANALYSIS MONTH February YEAR 2011 Sample pH - e:> + . O Total Suspended Solids (TSS) . O Settleable Solids (SS) LOCATION ID 0A7E TCAE 94 hr dock Analysis Date Analysis Time 24 hrdoC, UNITS ANALYSIS DATE m9n ANALT515 DATE MW 01B RA7C Sample #i 218111 1128 2/8/11 1420 9.2 218111 33 218/11 0.2 018 RMC Sampfe 92 2/8/11 1130 VS/11 1420 12.0 2/8/11 71 2l8/11 t0.2 018 AMC Sample 43 218111 1132 2A/11 1420 8.0 2 VI1 6 218/11 40.2 013 RMC Sample #4 218111 1136 218111 142D 6.9 _ 2l8/11 c2.5 2/8/11 qG SM'Pt� eor+Ff�1 Tyra Q antcl G G I hereby certify that I have reviewed and approve these data Laboratory Representative Y-a Enviro tal Chemists, Inc. i c3 iy 4 u _ aO2 Windmill Way + Wilmington, NC 28405 (910) 392-0223 (Lab) • (910) 392-4424 (Fax) F' 710 Bowsertown Road • Manteo, NC 27954 (252)473-5702 ANALYTICAL & CONSULTING CHEMISTS NCDENR- DWQ CERTIFICATE #94. DLS CERTIFICATE #37729 Customer: BBS CONTRACTORS 360 E. 24' Street Lumberton, NC Aria: Matt Lennon Date of Report: April 1,'2008 Purchase Order #: Report Number: 8-2586 REPORT OF ANALYSIS Date Sampled: 03/15/08 Report To: Matt Lennon Sampled By: Client 4Jj WATER- 'A Parameter 6TI�' -ska.{ tGl� OiB County Water Date # 5390 # 5391 # 5392 AngtgA PH, units SM 4500 H - B 5.94 7.80 7.40 3/24/08 Turbidity, as NTQ 2.8 56.5 0.4 * 3/18/08 SM 2310 B x3/19/08 Total Solids, TS mg/L 92 2,T92 72 3/20/08 SM 2540 B Dissolved Organic Carbon, DOC mg/L 5.8 1.4 3.8 3/24/08 SM 5510 B Manganese, Mn mg/L. < 0.005 0.006 0.011 3/24/08 EPA 200.7 Tin, So mg/L < 0.05 < 0.05 < 0.05 3/28/08 EPA 200.7 —T� q1 C- Zinc, Zu mg/L S EPA 200.7 / 0.020 9.52 < 0.005 3/24/08 Copper, Cu mg/L 0.0I2 < 0.005 0.015 3/24/08 EPA 200.7 Lead, Pb mg/L EPA 20000.7 < 0.003 0.025 < 0.003 3/28/08 Iron, Fe mg/L 0.288 0.272 0-018 3/24/08 EPA 200.7 Oil & Grease EPA 1664 A < 5 36 < 5 3/20/08 Chlorides, Cl - mg/L 8 922 31 3/31/08 SM 4500 Cl-B 1 Comments: -- Reviewed by f' - I = FommuspH CONTROL & MONITORING SYSTEM MODEL 5090S i 1 s Model 5000S Portable Building Enclosure The Fortrans system is installed in a portable utility building enclosure, 4 feet wide, 4 feet deep and 8 feet high. The Model 5000S is equipped with a steel access door with lockset, as well as lighting and a shelf. The Model 5000S is also built on a Trex* skid with Coex• flooring for durability and maximum water resistance. Supplied with an exterior GFCI outlet for the pump connection, and exterior cam lock quick -connect fittings for inlet and discharge hoses. Model 5000S is suited for exterior installation at a facility where the detention basins are in a remote location, or where equipment security may be of concern. Shipping weight 650 Ibs. Class 200 freight. FortranspH System Benefits • Optimize process and storm water treatment to comply with federal and local regulations. Reduce or eliminate costs of storing or off -site disposal of excess process water.-- • Operational Cost Savings. Fortrans pH control systems are exceptionally efficient, with 60% to 70% typical operational expense savings over acid -based PH adjustment systems. The Fortrans system reduces total suspended solids to EPA standards of less than 30 mg/ liter without additional chemicals or filters. • Maintenace Cost Savings. An elegant design allows Fortrans pH control systems to operate automatically, 24 hours a day. Routine maintenance is simple and easy. • Safety. Fortrans pH control systems use carbon dioxide in lieu of hazardous acids. Employees will not need protective equipment or safety training for handling hazardous acids used in other pH control methods. • Proven Reliability. Fortrans pH control systems, with our exclusive in -line CO2 injection and diffusion technology provides a proven pH control solution, with hundreds of installations currently operating throughout the United States. • Performance. Fortrans guarantees their systems will perform to their customers, satisfaction, and we back this with a 60 day purchase price refund offer. {Less Shipping} Options And Accessories Available Please visit us on line or call.... fortransfne.com info@fortransinc.com 919.365.8004 1.866.959.7267 M-F 8:30am - 5:30pm EST 7400 Siemens Rd.,Suite B PO Box 40 Wendell N.C. 27591 Model 5000S Portable Building Enclosure The Fortrans system is installed in a portable utility building enclosure, 4 feet wide, 4 feet deep and 8 feet high. The Model 5000S is equipped with a steel access door with lockset, as well as lighting and a shelf. The Model 5000S is also built on a Trex* skid with Coex• flooring for durability and maximum water resistance. Supplied with an exterior GFCI outlet for the pump connection, and exterior cam lock quick -connect fittings for inlet and discharge hoses. Model 5000S is suited for exterior installation at a facility where the detention basins are in a remote location, or where equipment security may be of concern. Shipping weight 650 Ibs. Class 200 freight. FortranspH System Benefits • Optimize process and storm water treatment to comply with federal and local regulations. Reduce or eliminate costs of storing or off -site disposal of excess process water.-- • Operational Cost Savings. Fortrans pH control systems are exceptionally efficient, with 60% to 70% typical operational expense savings over acid -based PH adjustment systems. The Fortrans system reduces total suspended solids to EPA standards of less than 30 mg/ liter without additional chemicals or filters. • Maintenace Cost Savings. An elegant design allows Fortrans pH control systems to operate automatically, 24 hours a day. Routine maintenance is simple and easy. • Safety. Fortrans pH control systems use carbon dioxide in lieu of hazardous acids. Employees will not need protective equipment or safety training for handling hazardous acids used in other pH control methods. • Proven Reliability. Fortrans pH control systems, with our exclusive in -line CO2 injection and diffusion technology provides a proven pH control solution, with hundreds of installations currently operating throughout the United States. • Performance. Fortrans guarantees their systems will perform to their customers, satisfaction, and we back this with a 60 day purchase price refund offer. {Less Shipping} Options And Accessories Available Please visit us on line or call.... fortransfne.com info@fortransinc.com 919.365.8004 1.866.959.7267 M-F 8:30am - 5:30pm EST 7400 Siemens Rd.,Suite B PO Box 40 Wendell N.C. 27591 Fortrans Process Water Management pH CONTROL SYSTEMS All standard' Fortrans pH Control Systems include: • The Fortrans exclusive in -line carbon dioxide diffusion and injection system (patent pending) adjusts the pH of process water and/or storm water automatically, on an as -needed basis. This carbon dioxide pH adjustment system is driven by a programmable logic controller that achieves, and then automatically maintains a target range (usually pH 7.5 to pH 8.0), for water stored in your detention basin. Target pH range is adjustable. Includes pH measurement cell, and fully automated operation. Highly reliable, and exceptionally ecbriomical to operate. • High efficiency stainless steel submersible pump with stainless steel impeller, thermally protected continuous -duty motor, and float assembly to protect against run -dry condition. The standard system pump yields approximately 70,000 gallons per day from a typical 12 to 15 foot deep detention basin, and has capacity to pump from basins or pits 20 feet and more in depth. • High quality pump boom, 2 feet high, with 30" boom reach, including a manual winch. • 1.5-inch pump connection and 1.5-inch discharge hoses (25 feet each) with cam lock quick connect fittings for quick and easy set-up. • Electronic flow rate meter to indicate that the system is operating within a normal flow range, or to indicate that maintenance cleaning of the pump inlet, or the system hoses, is required. • Factory installed industrial -duty surge suppressor to protect the system electronics. • Red light fixture to warn that the system pH has exceeded the alarm set -point. Provides automatic alarm indication that CO2 supply is exhausted, and your tank requires filling. • A system enclosure that is best suited to your facilities needs. - Feature an exclusive in -line carbon dioxide diffusion and injection system to precisely adjust the pH of process water in detention basins. - Reduce or Eliminate Cost of Storing or Disposal of Excess Process Water • Safer and Less Costly Than Acid Based Treatment Systems • Simple Design for Low Maintenance • Use Treated Water for Recycling -Dust Control - Irrigation -Truck Washing •Treated water meets pH and Total Suspended Solids limits for discharge or return to municipal waste . water systems ,.:. '"OxWspH CONTROL 8r + MONITORING SYSTEM MDDf[ 50908 Model 5000B Compact Metal Enclosure The Fortrans system is installed in a heavy gauge all aluminum enclosure with a sloped top. The piano hinged top and swing away doors allow for easy access to all system components. The Model 5000B is constructed on a Trex• skid with Coex° flooring for durability and maximum water resistance. Supplied_ with an exterior GFCI outlet for the pump connection, exterior cam lock quick -connect fittings for inlet and discharge, and grommeted enclosure penetration for CO2 supply hose. Light in weight, yet heavy-duty, the Model 5000E is ideal for exterior installation within a secured facility. Shipping weight 290 lbs. Class 55 freighL Precipitation frequency Data Server Page 1 of 4 i POINT PRECIPITATION �# FREQUENCY ESTIMATES FROM NOAA ATLAS 14 .... f North Carolina 33.9055 N 78.4608 W 26 feet from "Precipitation -Frequency Adas of the United States" NOAA Atlas 14, Volume 2, Version 3 G.M. Boanin, D. Martin, B. Lin, T. Parzybok, M.Ydaa, and D. Riley NOAA, National Weather Service, Silver Spring, Marytand, 2004 Extracted: Tue May 3 2011 Confidence Limits I seasonaiity I Related Info I GIS data .Maps I Docs Retum to state Map Precipitation Frequency_ Estimates (inches) ARI* 5 10 Fx5io 306fl120 l02030 45 60 3hr 6hr I2hr±24hr 48hr 4d F-d-ay'•(Years) min ; min `min ; min'; min 5�5`555�5 day. 11 y , da �- 4.51 O-i1 ; lAl 1.38 ,; 2.06. 2.22 2,72 3.20 , 3.70 4.32 4.82 5.55 ' 6.25 : 8.39 10.41 ' 12.98; 15.59 ti 0_60 ; 0.96 1.20 166 ? 2.09' 2.50 F2 69-1 3.31 ! 3 88 ' 4.49 : 5,23 , 5.83 f 6.69 ' 7.50 I0.00 I2.37 15.34 18.37 r 5 0.69 : 1.11 '_ 1.41 2 QO 2.56 i 3.15 ; 3.40 t 4.18_ 4.95 ; 5.81 � 6.70 7.37 ; 8.40 • 9.26 } 12.16 : 14:$0 ' 18. 11 21.44 10 0.7$ 1.24 ` 1.57 2.2$ 2.96 3.72 4.05 , 4.99 , 5.93 694 : 7.9b 8.67 ; 9.81 10.72 13.92 16.73 20.32.23.84 25 0.88 1.40 '. 1.77 ' 2.62 3.49 ' 4.49' 4.95 6.12 ; 7.33 8.65 9.84 ; 10.59 111.84 i 12.79 , 16.40 ] 4.39 r 23.30 27.02' 50 0.95 , 1.52 ; 1.92 ; 2 89 3.92 ` 5.16 5 75 ' 7.13 ' 8.59 10. ] 5 l L46 : 12.21 13.53 � 14.50 118.41 21.50 25.66 29.47 100 1, 1.03 i.64 2.07 j JT1T4.36 1 5.86' 6.61- ; 8.22 9.96 111 82 13.28 1399; 15.36 16.33: 20:52: 23 65 2$.03 31.89 20fl ; 1.11 1,75 ° 2.21 : 3.44 ! 4.83 ; 6.61 7.55 9.43 ` 11.56 13.71 ` 15.30 15.94 i 17,33 18.28 22_74; 25.87 30.46 34.32 500 ' 1.20 1.90 .2.40 ; 3.81 i 5.47 7.70 ; 8.94 , 11.23. 13.82 ; 16 59 18.36 18.91E 20.18' 21.09 ; 25.87. 28 92 33.76 ; 37.54 1000 , 1.29 + 2.03 ' 2.54 4 12 ; 6.02 8.64 10.17' l2 83 ; 15 91 ; 19 12. 21.01 21.45 t 22.57 23.41 28.41 t 31 33 36.33 39.99 . These precipitation frequency estimates are based on a partial duration setim ARI is the Average Recurrence Interval. Please refer to NOAA Aftas 14 Document for more information. NOTE: Fomratting tomes estimates near zero to appear as zero. * Upper bound of the 900/a confidence interval Precipitation Frequency Estimates (inches) ARl**, 5 10 15 30 60 ! 120, 3 6 12 24 48 4 7 10 26 30 45 60 ears i mm , min mm : min : min I m►n ; hr hr ? hr ' hr hr day_ : da da t da da da[,.day - - -- (Y- _� ![ Fi 1 t ��I Y_ l _.Y-`!-y.•I y y _ ±�1 ! 0.55 ! 0.87 ? 1.09 r 1_50 ; 1.86 ` 2. 25 2.45 3.00 3.56 ? 4.16 _ 4.77 _' 5.27 6.O 1 b.74 ? 8.97 E 1 ] .09 13.77 16.4b �;r 2 0.65 ] .04 i 1.30 ] 80 ', 2.26 ' 2.74 ' 2.98 , 3.66 4.33 4.9$ 5.78 : 6.36 7.25 ^ 8 O8 10.70 13.17 ; 16 28 : 19.40 5 10.75 : 1.20 ; 1.52 2 16 ! 2.77 ; 3.44 3 75 4_62 5.52 : 6.43 ! 7_41 8.04 + 9.10 9.99 _ I3.01 : 15.76 , i 9 22 22.64 _-10 f 0.84 , I_34 ff 2.46 ; 3.20 `: 4,05 = 4.46 5 50 ' 6.60 7.68 8.80 ': 9.46 10.63 1 i.56 1488! 17.83 ; 21 56 25.16 _25 0.94 ` 1.50' I.91 ; 2.82 3.76 4.89 ' S.44 16.74 ; 8.13 : 9.55 10.88. 11.55 12.83 13.79 i 17.53 ; 20 66 ; 24.75 28.54' 50 1.03 1.64 2.07 , 3.12 4.22 SY61 6.32 7.84 ' F9.5 I I I 20. 1269' 13.34 68 14 15.6b ` ] 9.72 ; 22.96 t 27 28 31.17 IOfl I^ 11 ; i.76 : 2.23 3.41 ' 4.70 6.38 : 7.25 ' 9.03 : 11.03 13.06 14.73 15.32 16.b9 17.66 22.03 25.31; 29.87 33.81:. 200 1.19 ! 1.89 2.38 3.71 ! 5.21 `: 7 l9 i 8.27 : 10V35 12 72 15.17 ? 17.04 17.52 18.89 19:85:, 2451. 27 76 � 32_57 : 36.47' 500 ' 1.30 ; 2. 66 2. 99 4.12 5. 11 ' 8.38 9.81 12.35 15 -o- 18.44 , 20.55 ; 20.9I 2216 23.06 i 28�08" 31.21 j 36 30 40.08 1000 ; 139 2.19 2.75 4.46 6.51 = 9.43 ' 11 18 : 14.13 : 17.59 21 36 , 23.56 ; 23.88.24.94 25 77 ` 31 O1 33.98 39.26 42.90 The upper bound of the confidence interval at 90% confidence Level is the value which 5% of the simulated quantile values for a given fiequency are greater than. These precotaWn Imquency estimates are based on a partial duration series. ARI is the Average Return xe Interval. Please refer to NOAA Atlas 14 Document for more information. NOTE: Formatting prevents estimates near zem to appear as zero. * Lower hound of the 90% confidence interval Precipitation Frequency Estimates (inches) ARi** 5 10 15 30 ' 60 120f 3 6 12 24 48 4 7 10 20 30 45 60 ' (years)° min ; min , min ; min , min min hr hr ` hr hr hr Iday fday day ! day day i day day 1 0.47 0.75 0.94 ? 1.28 1.60 1.90 2_04 2.49 _ 2 90 3.37 3.95 ; 4.45 5:14 ; 5,83 7 _86 9.86 12.24 14.76 r! 0.56 F 0.89 ].12 ; 1,54 ; 1.94 2.31 2.47 ; 3.02 3 51 4.10 4.79 S37 6.21 6 98 937 1 L63! 14 48 17.38 5 O.b4 1.03 1 _30 1 85 ; 2.37 ' 290 3 1 I 3.81 , 4 47__ 5.29 6J2 ; 6.78 _+ 7.77 8 60 ' l 1 38 ; 13 91 17 08' 2026 i 10 0.72 i 1.15 1.45 2.10 2.74 ' 3.41 3.69 4V53 5 33 , b.30 : 7.23 ' 7.95 __ 9.05 ; 9.93 13_00 i 15.69 ; 19 12 ! 22.48 25 0.80. 1.28 I _62 2.40 3_20 ; 4. 99 4.48 : 5.52 : f6 54 ; 7.79 8.86 9.63 10.86 11 79 ; 15.24 ! 18.11 ; 21.86 ! 25.4 l 50 0.87 ' 1.39 , 1.76 ', 2.65 3.59 4.68 ; 5.17 i 6.38 7.61 9. 55 ; 10.23 ; 11.03 12.33 , 13.29 17 02 19 99 ; 23 97 ! 27.62 r�r-1 A r .1 -r ----I r-r -- r r r r r 1 -1 r http:/lhdse.nws.noaa. gov/cgi-binlhdsc/bui ldout. perl?type=pf&units=us&series=pd&staten... 5/3 /2011 Values of Runoff Coefficient (C) for Rational Formula Page I of I Values of Runoff Coefficient (C) for Rational Formula Land Else_ C_ Land Use Lawns: Sandy soil, flat, 2% 0.05-0.10 Business: Sandy soil, avg., 2-7% 0.10-0.15 Downtown areas 0.70-0.95 Sandy soil, steep, 7% 0.15-0.20 Neighborhood areas 0.50-0.70 Heavy soil, flat, 2% 0.13-0.17 Heavy soil, avg., 2-7% 0.18-0.22 Heavy soil, steep, 7% w 0.25-0,35 Agricultural land. Bare packed soil *Smooth 0,30-0.60 Rough 0.20-0.50 Residential: Cultivated rows Single-family areas 0.30 - 0'.50 *Heavy soil, no crop 0,30-0.60 Multi units, detached 0.40-0.60 *Heavy soil, with crop 0.20-0.50 Munti units, attached 0.60-0.75 *Sandy soil, no crop 0.20-0.40 Suburban i 0.25-0.40 *Sandy soil,with crop 0.10-0.25 Pasture *Heavy soil 0.15-0.45 *Sandy soil 0.05-0.25 Woodlands 0.05-0.25 Industrial. 1 Light t�are as Streets: Asphaltic Concrete 0.70-0.95 Heavy areas 0.60-0.90 Brick 0.70-0.85 FFii-k—s-, cemeteries J1 0.10 7 0-2-5 !FU-nlm-proved areas .0.10-0.30 IPlaygrounds __._.JFO.20-0.35 71Drives and walks F 0.75-0.85 FRailroad yard areas 0.40 Roofs *Note: The designer must use judgement to select the appropriate "C" value within the range. Generally, larger areas with permeable soils, flat slopes and dense vegetation should have the lowest "C" values. Smaller areas with dense soils, moderate to steep slopes, and sparse vegetation should assigned the highest "C" values. http://water.rne.vccs.edu/courses/CfV246/table2_print.htm 7/7/2011 ' � Ivvlui l.2Yl'VIAfAi3 ,,GI:ICIiLI'y OT AiaZ� Page 1 of 2 North Carolina Elaine F. Marshal! DEPARTMENT OF THE +_ J Secretary SECRETARY of TATE PO Box 29622 Raleigh, NC 2762"622 (91.9;t;B07-2000 Date: 7/5/2011 Click here to: View Document Filings l Sign Up for E-Notifications I J Pre -populated Annual Report Fillable PDF Form I File an Annual Report l Corporation Names -'-NV OIB READY MIX LEGAL CONCRETE, LLC Limited Liability Company Information SOSiD: 1025021 Status: Current -Active Effective Date: 1 /31/2008 Dissolution Date: Annual Report Due Date: Citizenship: DOMESTIC 'State of Inc.: NC Duration: PERPETUAL Annual Report Status: CURRENT Registered Agent Agent Name: Office Address: Mailing Address: Principal Office Office Address: Mailing Address: Officers Title: Name: Business Address: Title: Name: SIMMONS, GRADY L., JR 360 E 24TH STREET LUMBERTON NC 28358 POST OFFICE BOX 944 LUMBERTON NC 28358 1581 LOBLOLLY LN. OCEAN ISLE BEACH NC 28469 POST OFFICE BOX 944 LUMBERTON NC 28358 MANAGER DANIEL SIMMONS POST OFFICE BOX 944 LUMBERTON NC 28358 MEMBER GRADY L. SIMMONS JR. 1Lh008A9100! 96 of Z�%�r- STATE OF NORTH CAROLINA `Y DEPARTMENT OF THE SECRETARY OF STATE LIMITED LIABILITY COMPANY AR OIB READY 1VIIX CONCRETE, LLC SOSID: 1025021 Date Filed: 1/31120081:56:00 FM Elaine F. Marshall North Carolina Seeretary of State C200803100196 Pursuant to §5713-2:20 ofthe General Statutes ofNorth Carolina, the undersi ned does hereby submit these Articles of Organization for the purpose offohning a rinutea liab�ty omnanv. I . The name of the limited liability company is: 01B READY MIX CONCRETE, LLC 2. The latest date on which the limited liability company-is-to•dissoLve-i;RED. M . 3. The name and address of the organizer executing these articles of organization are as follows: Jason W. Wenzel P. O. Box 1567 Smithfield, North Carolina 27577 4. The street address and county of the initial registered office of the limited liability company are: Number and Street: 360 E 24`' Street City, State, Zip Code: Lumberton, North Carolina 28358 County: Robeson County 5. The mailing address of the initial registered office is: Post Office Box 944 Lumberton, North Carolina 28358 6. The name of the initial registered agent is: Grady L. Simmons, Jr. 7. This limited liability company is a manger -managed LLC: except as provided by N.C.G.S. Section 57C-3-20(a), the members of this limited liability company shall not be managers by virtue of their status as members. 8. These articles will be effective immediately upon filing. This 30'' day of January, 2008. J n W. Wenzel, Organ r 4I13 READY MIX 1581 Lobtolly Lane SW Seaside, NC 28468 STATEMENT OF CONCRETE MIX DESIGN & SOURCE OF MATERIALS Date: 05-JUI-11 Project_ - R.M_ Producer 0IB Rea0f 1NIx Placement TRUCK Plant Location: Seaside, NC Concrete Type 3000 PSI Contractor. - Mix Design - One Cubic Yarsd Based on SSD Condition Class of Concrete: 3000 PSI Aggregate Type: # 67 STONE 'Lab Mix Design No_: Design Air Content (%): 2.0 Materials: Volume Source: Producer/Location: Cement: Type 1 350 lb_ 1.7$ Holcim Georgetown, SC Fly Ash: Class F 150 lb. 1.07 SEFA Georgetown Fine Agg. + M 1537 lb. 9.33 H.R Coffin Sand Conway Pit Coarse Agg. + M 1529 lb. 10A0 Grand Strand Materiafs Grand Strand Agg. Total Water / CY 3Z0 gal. 4.28 City Well Admit. (AE) "' az. 0.54 Chryso Air 260 Chryso Inc Admix. (HRWR) 0.0 oz_ O ilma 203 g±ryEo Inc Adrnbc. (W.R.) 35.0 oz. Plsstimix 50 Chryso Inc Admix. (Retarder) 0.0 oz PlasUrnix 100R Chryso Inc Totall 27.00 The quantity of mixing water shown is to produce a 4.00 inch stump The water cement ratio by design 0.53 NOTE: All test to be performed at the at the ready mix truck (1) The quantities of fine and or coarse aggregates necessary to conform to specification in regard to consistency and workability shall be determined by the method described in "Recommended Practice for Selecting Proportions for Concrete" (ACI 211.1) and "Placing Concrete by Pumping Methods" (ACI 304), using the absolute volume basis. The WIC ratio, slump, cement and air content shall conform to the Standard Specifications or requirements for the class of concrete desired_ Admixtures used will conform to ASTM C 494 or ASTM 260 for Air Entrainer and dosage rates will be determined as needed. MIX DESIGN DATA FA_ FM Z44 FA -Abs% FA_ - Sp. Gr. Z64 CA. -Abs% Prepared by: Submitted by: 0.2 CA_ - Sp. Gr. 2.45 0.6 C.A. - Unit Wt. 101.6 Mortar - Cubic Feet (Company Representative) — As required "Retarder (Chryso Tard 100R)may be added per manufacturer's recommended dosage rate of 1-2 oz. per 100 weight of cementitious material. Dosage rates vary contingent upon customer's desired results_ The addition of this admixture must be approved in writing by project architect or engineer prior to its use on this project and specifically requested by the finisher before it is to be included in each batch of concrete. "Accelerator (Chryso Turbo Cast C4A) may be added per manufacturer's recommended dosage rate of 16-32 oz. per 100 weight of cementitious material. 16 oz per 100 weight is considered 1 % accelerant whereas 32 oz per 100 weight is considered 2% accelerant The addition of this admixture must be approved in writing by project architect or engineer prior to its use on this project and specifically requested by the finisher before it is to be included in each batch of concrete. "Super Plasticizer (Chryso Optima 256) may be added per manufacturers recommended dosage rate of 3-4 oz: per 100 weight of cementitious material. The addition of this admixture must be approved in writing by project architect or engineer prior to its use on this project and specifically requested by the finisher before it is to be included in each batch of concrete. JIB Ready Mixed Concrete PO BOX 6965 1581 Loblollv Lane ocean Isle, NC 28469 Date: Tuesday, July 05, 2011 I iwK[61-10_ ML I Ref: setter of Authorization —Wilbur Dees, P.E PHONE: (910) 575-HARD (4273 ) FAX: (910) 575-4293 Wilbur Dees, a registered Professional Engineer, is hereby given Authorization to act as our agent for the purpose of obtaining permitting as required by NCDENR to operate our concrete plant. Our Authorized Engineer's Contact Information: Wilbur Dees, P.E 2927 Middlesex Rd Fayetteville, NC 28306 Phone: 910-6244779 e-mail: wdees@nc.rr.com If further documentation is needed, please do not hesitate to contact me_ Sincerely, Daniel Simmons OIB Ready Mixed Concrete, LLC 1 G �} f J� fi -� j' r� Jam:. '�._.✓`I_-. 1 t , •:lilt 7' ,� � �yy �n ��,,� sue• = � 1 •tit �: s;, �� � +�� �'a16 NCG 140403 0I13- Ready Mix Latitude: 330 54' 20" N Longitude: 780 27' 39" W County: Brunswick Receiving Stream: UT to Jinnys Branch Index No.: 15-25-2-15-1-(1) Stream Class: C; Sw Sub -basin: 03-07-59 (Lumber River Basin) Facility Location WILBUR E. DEES, P.E., P.L.S. CONSULTING ENGINEERING AND LAND SURVEYING 2927 MIDDLESEX ROAD FAYETTEVILLE, N. C., 28306 PHONE / FAX (910) 425-1941 CELL (910) 624-4779 JUNE 24, 2011 STORMWATER PERMITTING UNIT DIVISION OF WATER QUALITY 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 RE: OIB READY MIX CONCRETE, LLC PO BOX 6965 1581 LOBLOLLY LANE OCEAN ISLE BEACH, NORTH CAROLINA 28469 READY MIX CONCRETE PLANT NARRATIVE OIB READY MIX CONCRETE, LLC, IS A PERMANENT INDUSTRIAL FACILITY THAT PRODUCES A WET MIX OF CEMENT, SAND, GRAVEL, FLY ASH AND SOME ADMIXTURES THAT ENHANCE THE WET MIX. THE PLANT ACTIVITIES ARE CLASSIFIED AS STANDARD INDUSTRIAL CLASSIFICATION (SIC) CODE 3273, READY MIXED CONCRETE (RMC). IT IS THE INTENT OF OIB READY MIX CONCRETE, LLC, TO INSTALL AND OPERATE A PROCESS WASTEWATER RECYCLE SYSTEM FOR WASHING OF CONCRETE DELIVERY TRUCKS. THE RECYCLE SYSTEM WILL CONSIST OF THREE HOLDING BASINS, A RECYCLE BASIN, A WASH DOWN BASIN AND A DETENTION BASIN. DURING NORMAL OPERATIONS, THE RECYCLE SYSTEM WILL OPERATE AS A CLOSED SYSTEM WITH NO DISCHARGE. DURING RAIN EVENTS THE HOLDING BASINS WILL OVER FLOW INTO THE DETENSION BASIN WHERE SUSPENDED PARTICLES WILL SETTLE AND THE PH FACTOR MONITORED AND ADJUSTED WITH A FORTANS SYSTEM TO ALLOW THE DISCHARGE WASTEWATER TO COMPLY WITH THE MANDATORY REQUIREMENTS OF 30 MGIL FOR TOTAL SUSPENDED SOLIDS (TSS), 5 MGIL FOR SETTLEABLE SOLIDS (SS), AND 6-9 SU FOR PH. THE OIB READY MIX CONCRETE, LLC, OPERATIONS IS LOCATED ON A 3.99 ACRE TRACT OF PROPERTY IN BRUNSWICK COUNTY, NORTH CAROLINA. THE SITE IS THE LOCATION WHERE A PREVIOUS READY MIX CONCRETE COMPANY OPERATED FOR A CONSIDERABLE NUMBER OF YEARS. THE GEOGRAPHICAL LOCATION IS LATITUDE 33 DEGREES 54 MINUTES 20 SECONDS N AND LONGITUDE 78 DEGREES, 27 MINUTES, 39 SECONDS W. ENCLOSED, HEREWITH, IS DRAWING SHEET W-1 WHICH IS A SURVEY OF THE PROPERTY WHERE THE READY MIX PLANT IS LOCATED. ALSO ENCLOSED, HEREWITH, IS DRAWING SHEET W-2 WHICH IS A SITE PLAN FOR THE PROPERTY THAT INCLUDES A TOPO. THE PROPERTY IS RELATIVELY FLAT. RAINFALL SHEETDRAINS ACROSS THE PROPERTY TO THE NORTHERN PROPERTY LINE. THERE ARE OPEN DRAINAGE DITCHES THAT PARALLEL THE SOUTHERN AND WESTERN PROPERTY LINES. THERE IS ALSO AN OPEN DRAINAGE DITCH THAT PARALLELS THE EASTERN PROPERTY LINE. THESE DITCHES FLOW WATER OFF THE NORTHERN PROPERTY. THERE IS SOME FLOW OF WATER IN THESE DITCHES MOST OF THE TIME ALTHOUGH THE FLOW IS RELATIVE LOW. ALL WATERS DRAIN NORTHWARD TO ITS RECEIVING STREAM, UT TO JINNYS BRANCH WHICH IS ABOUT Y2 MILE FROM THE PLANT SITE. THE STREAM IS CLASSIFIED C: SwAND IS IN SUB -BASIN 03-07-59 (LUMBER RIVER BASIN). THE ABOVE REFERENCED READY MIX CONCRETE PLANT IS A LOW PRODUCTION CONCRETE PLANT. IT PRODUCES APPROXIMATELY 15,000 CUBIC YARDS OF CONCRETE MIX PER YEAR. FOR A FIVE DAY WORK WEEK AND 50 WEEKS PER YEAR THIS IS APPROXIMATELY 60 C.Y. OF CONCRETE MIX PER DAY. USING 10 C.Y. MIXER TRUCKS TO DELIVER THE PRODUCT TO JOB SITES, APPROXIMATELY 10 MIXER TRUCK LOADS PER DAY ARE BATCHED. MIXER TRUCK OIL CHANGES AND REPAIRS ARE "OUT SOURCED" TO PRIVATE BUSINESSES. MIXER TRUCKS ARE FUELED "ON SITE" DAILY. MIXER TRUCKS REQUIRE THEIR MIXER DRUMS TO BE WASHED A MINIMUM OF ONCE PER DAY. AN ADDITIONAL WASH OF APPROXIMATELY ONE PER DAY IS REQUIRED DUE TO THE OCCASIONAL RETURNED OF UNUSED MIX MATERIAL FROM THE JOB SITE, APPROXIMATELY 250 GALLONS OF WATER IS REQUIRED FOR EACH WASH DOWN. THIS GENERATES APPROXIMATELY (250 GALLIONS PER WASH)(TWICE PER DAY)(10 TRUCK LOADS) 5,000 GALLONS OF WASTE WASH WATER EACH DAY. THE CONCRETE MIX MATERIALS CONSIST OF SAND, CRUSHED STONE, CEMENT, FLY ASH, LIQUID ADMIXTURES AND WATER. THE SAND AND STONE ARE MATERIALS THAT HAVE BEEN PRE -WASHED BEFORE DELIVER TO THE PLANT SITE. - THE CEMENT AND FLY ASH ARE STORED IN METAL SILOS. THE ADMIXTURES AND WATER ARE STORED IN CLOSED METAL OR PLASTIC CONTAINERS. THE SAND AND CRUSHED STONE ARE STORED IN THREE SIDED OPEN STORAGE BINS. ALSO STORED ON SITE, IN OTHER OPEN STORAGE BINS, ARE RIP RAP, CRUSHER RUN MATERIAL AND RECYCLED WASTE CONCRETE PRODUCT. THE RIP RAP, CRUSHER RUN MATERIAL AND THE RECYCLED WASTE CONCRETE PRODUCT ARE NOT A COMPONENT OF THE READY MIXED CONCRETE MATERIAL. THEY ARE MATERIALS SOLD TO ENHANCE THE SERVICES OF THE READY MIX CONCRETE OPERATIONS, THERE ARE NO HAZARDOUS WASTE MATERIALS USED NOR STORED ON THIS SITE. SINCERELY YOU S, WfLBURE. DEES E., S. E. Ord A I �/zq/zo// OPERATIONS NARRATIVE DURING NORMAL PLANT OPERATIONS WASTE WATER WILL BE CREATED WHEN THE STOCK PILES ARE SPRAYED TO CONTROL DUST AND MOISTURE CONTENT OF THE SAND AND STONE. THIS IS WASTE WATER AREA #1 AS SHOWN ON SHEET W-4. THE AMOUNT OF WASTE WATER CREATED FROM THIS OPERATION WILL BE LESS THAN 1,000 GALLONS PER DAY. THIS WASTE WATER WILL BE COLLECTED IN THE Y2 ROUND DRAINAGE PIPE AND EMPTIED INTO HOLDING BASIN #1. WASTE WATER CREATED FROM THE DAILY PLANT OPERATIONS AND SHOWN ON SHEET W-4 AS WASTE WATER AREA #2 WILL APPROXIMATE 1,500 GALLONS. THE WASTE WATER CREATED FROM THE TRUCK WASH AREA WILL BE APPROXIMATELY 5,000 GALLONS PER DAY. THIS WATER IS DEPOSITED DIRECTLY INTO WASH DOWN BASIN # 4. APPROXIMATELY 2,500 GALLONS OF WASTE WATER WILL BE CREATED DAILY IN EXCESS OF THE WASTE WATER THAT IS RECYCLED. ONE HOLDING BASIN HAS THE CAPACITY TO STORE THIS WASTE WATER OVER TWO WEEKS BEFORE IT WOULD FLOW INTO THE RETENTION BASIN. DURING THE 10 YEAR, 24 HOUR STORM, FOR THIS PLANT'S LOCATION, THE AREA WILL RECEIVE APPROXIMATELY 6.94 INCHES OF RAIN. WHEN THIS EVENT OCCURS, THE NORMAL PLANT OPERATIONS WOULD BE SHUT DOWN BECAUSE THERE WOULD BE NO DEMAND FOR CONCRETE DURING A STORM EVENT. HOWEVER, THIS RAIN EVENT, WITHOUT ANY INTERPOLATION, WILL CREATE 103,985 GALLONS OF WASTE WATER FROM THE STOCK PILES, PLANT AND HOLDING BASINS WHERE WASTE WATER IS STORED. HOLDING BASIN #2 AND THE RETENTION BASIN #6 HAS A CAPACITY OF 112,500 GALLONS WITH A 12 INCH FREE BOARD. THE CAPACITY OF THESE TWO BASINS CAN HOLD THE 103,985 GALLONS OF WASTE WATER CREATED BY THE ABOVE REFERENCED 10 YEAR STORM. THE PH FACTOR OF THE WASTE WATER CAN BE MONITORED AND_ ADJUSTED BY THE FORTANS PH CONTROL AND MONITORING SYSTEM BEFORE ANY RELEASE OF THE STORM WATERS IS ALLOWED. THE SETTLEABLE SOLIDS (SS) AND THE TOTAL SUSPENDED SOLIDS (TSS) WILL BE TESTED FOR THE ALLOWABLE LIMITS BY "MERITECH" LAB BEFORE ANY RELEASE OF THE STORM WATER IS ALLOWED. FROM THE PREVIOUS TESTING PERFORMED BY MERITECH, INC - II, THE DETENTION TIME NEEDED FOR THE "SS" AND "TSS' TO COMPLY WITH THE ALLOWABLE LIMITS SHOULD BE LESS THAT 48 HOURS. BY SIZING BASINS, THAT WILL CONTAIN THE PRESCRIBED WASTE WATERS, ACCURATE DETENTION TIMES CAN BE ESTABLISHED AND VERIFIED BY ACTUAL TEST RESULTS BEFORE ANY STORM WATERS ARE RELEASED. ALL BASINS, DRAINAGE PIPE, SILT FENCE AND ROCK DAMS 1 DITCHES WILL BE INSPECTED WEEKLY AND MAINTAINED AS NECESSARY. AT A MINIMUM, ALL BASINS WILL HAVE THE SETTLED FINES REMOVED WHEN THEY ARE 20% FULL. THE TRUCK WASH BASIN WILL REQUIRE THE RECLAIMABLE MATERIALS TO BE REMOVED TWICE YEARLY OR AS REQUIRED. ALL BASINS WILL BE PIPED AND VALVED TO FACILITATE_ CLEANING WHEN REQUIRED. THE REQUIRED DATA WILL BE MONITORED AND THE REQUIRED REPORTS AND LOGS MAINTAINED FOLLOWING ANY STORM EVENT THAT RECORDS A Y2 INCH RAINFALL. AN ON SITE RAIN GAGE WILL BE MONITORED AND A LOG BOOK FOR RAIN EVENTS WILL BE RECORDED DAILY. - "` V 1 ^� (.0 n 00 00 N w U. Z n J � � n � QX m ^ � r� W H Q XZ CO, �Lli N N 00 N V U U a W U ~ Z O W U U 0 0 a �a 0 a 00 H W a 0 a IDote: MARCH 15, 2011� Drawn by: WEDJI [Checked by: WED Scale: 1" = 60"-0" Sheet No. VV-1 2�1 2. VICINITY MAP NTS 1 TJ •G 1 S 2'53'55" W to o•zo'ia" r w (h / C ` C BLUE B SAND o STONE CABC 1#67 #78 DOT SAND SAND OIB READY MIX CONCRETE, LLC JL'F.,+O S 2'53'32" W DEED BOOK 2640 PAGE 944 PAPTW *KI QC7PkA 301 _ �9 _30080/ — ,X 29.14 27X — 26.49 X 27.61 GRAPHIC SCALE 1 INCH = 30 FEET CHAIN '_INK FENCE HEIGHT — VARIES OPEN [ITCH DEPTH — 36" MAX. EXISTING CONTOURS SPOT ELEVATIONS BINS FORMED WITH CONCRETE BLOCKS OPEN END FOR LOADER OPERATION (PRECAST BLOCKS 18"x18"x 48") m=a=m=m===mw=mma JUNE 24, 2011 RESUBMITTAL SIMMONS PROPERTIES DB 2640, PAGE 944 OCEAN ISLE BEACH SHALLOTTE TOWNSHIP BRUNSWICK COUNTY, NORTH CAROLINA I� , n W n J� Z WN C7) h� c ry L� / WZ Cnfr , n r) N N a 0 a 0 h A z Date: JUNE 24, 2011 �� Drawn by: WED Checked by: WED Scale: 1" = 1— 0 D W-2 2 3 0000 ro `i ECM ( 38.18 1 1 1 1 1 i 1 1 CONSTRUCTION NOTES ORECONFIGURE STOCKPILE OPEN REGRADE BATCHING AREA TO DRAIN BINS TO DRAIN AS INDICATED, \61 O LAY 1 /2 0, 15" CPP (MUST BE CONTINUOUS GRADE). C� STORMWATERS SHEET DRAINS TO NORTHEAST PORTION OF THE PROPERTY 3 O NEW HOLDING BASIN. BASINS ARE EXCAVATED TO HOLD THE QUANITIES SHOW WITH A 12" FREEBOARD. �� 65� t OF AREA IS CONCRETE PAVEMENT AND IMPERVIOUS. 4 NEW RECYCLED WASH WATER FOR MIXER DRUMS. 960 GAL OVERHEAD TANK / PUMP. "V" DITCH / FABRIC AND RIP RAP O RELOCATED FUEL PUMPS 10 RIP RAP DRAINAGE WITH FABRIC 11� 4" PVC WITH CENT. PUMP DEED BOOK 2640 PAGE 944 N 2'32'16" E 674.71' 1 31.96-4c_..._ O EARTHEN BERM 29.91 --- ------- ---- -- - -- __--- ---_.35� RECLAIM W -' MATERIAL Z _ - �33'--------- - ----------- _- HOLDING BASIN - #1 0 49$'t 15" 1 /2 b CCP-[-:]PUMP1 CONEX Pp HOUSE ROCK DAM / FABR 10'x40'x4' - 12,000 GAL "�'- M � \ \ �' x W 91 UI N X 36.62 S P 25' HOLDING BASIN _ #) IC 28,125 GALS 5�01 25' 1 I� / O \\ M o z r ww � WATER TANK �� 3 E 34 T - - - LQ ADMIXTURESLq \ I,i �\ �„�__`� ✓// RETENTION SHE LL PARCEL # 243JA039 I� E, PANEL ZONED: OI—C=3 ` I _ , CONCRETE RAMP / , � 1 i 25' S \ 3.99 ACRE \ \ I CONTROL I \ / / NOUSE I � ,\ \� \ J _ I o Q i 25' sto, CONVEYOR 34'4\ a X <= w I �� U / 34,139 ORg34.50 W X INS I ` 1 / P 33.85 I 1 3 45 CPP OVERHEAD RECYCLED ® " WATER STORAGE TANK 1 pvC -/ O f i I; ROCK ,v„ p11CH o M CXD NEW PLATFORM I O / SETTLING x34.55 \ - 35 / - - 34- J3 / BASIN #5 �J T 32' 32' �- r / 0S' � 35.34 32.82 — — I 1 �0 t') X 36.26 I �J I { w N 00 oo I co { 35, `D - - c+� 149.21' S 2'53'55" W 37.89 ,I 35.99 35.87 1 1 OIB READY MIX CONCRETE, LLC GRAPHIC SCALE 30 0 15 30 Ir1 1 INCH = 30 FEET S 2'5332" W 30 - / _ i / 29,14 X '^ 26.49 / X 27.61 LEGEND CHAIN LINK FENCE HEIGHT - VARIES OPEN DITCH DEPTH - 36" MAX. MIXER TRUCKS TRAVEL PATTERN EXISTING CONTOURS NEW CONTOURS RIP RAP FOR DAM / DITCH SILT FENCE - - - HALF -ROUND 15" CPP UNDERGROUND PLASTIC PIPING - - - - - - - - - - NEW CONSTRUCTION 0 ROCK DAM / SILT FENCE ROCK DAM / FABRIC BINS FORMED WITH CONCRETE BLOCKS OPEN END FOR LOADER OPERATION ECM --------------... 7t - 29.59 2. 3�X� 10' WEIR DISCHARGE --� ��p\N �\w �i II II I — II w I I 's o I I N M 00 (I i III X 30,19 j` / S �£T QRgINS SCHARGE-�--+.•- '/I NOTE: SEE DRAWING SHEET W-6 FOR LARGER VIEW OF THE HOLDING AND DETENSION BASINS. RESUBMIUfAL JUNE 24, 2011 SIMMONS PROPERTIES DB 2640, PAGE 944 OCEAN ISLE BEACH SHALLOTTE TOWNSHIP BRUNSWICK COUNTY, NORTH CAROLINA a o 00 W • A-+ W U Z. WZ LLJ 0') A� p Q a ry J Z wz U , a- 0 a N N 00 N U x U U H w H U \/r W U U 0 n Q w Fri 0tt MMM�1 h+i 0 00 Date: MAY 15, 2011 Drawn by: WED Checked by: WED Ij Scale: 1" = 30'-0" 11 heet No. w-3 WASTE WATER AREA #1 = 15,900 S/F 300, 9 a m FUEL FUEL TANK TANK 27.8' M Q 13.3' r 43.3' ECM 149.21' 5 2'53'55" W 15,900 S/F STOCK PILES 6,618 S/F PLANT OPERATIONS 1,250 S/F WASH DOWN AREA 23,768 S/F RECEIVING 7 INCHES OF RAINFALL 23,768 S/F ( 7/12) = 13,864.67 CF OF RAINFALL 13,864.67 CF OF RAINFALL (7.5 GPCF) 103,985 GALS 0 w WASTE WATER #1 AREA #67 PARCEL # 243JA039 ZONED: 01-C-3 3.99 ACRE G= N 2'32' 16" E #78 0 25' n 1,250 SF WASTE WATER AREA #3 = 1,250 S/F OIB READY MIX CONCRETE, LLC 524.48' S 2'5332" W DEED BOOK 2640 PAGE 944 HOLDING BASIN - #1 HOLDING BASIN' _ 12 PUMP HOUSE 10'x40'x4' - 12,000 GALS WATER TANK VH 0= ADMIXTURES DETENTION z PUMP W r � r I � r � e r � o< I-- r o WASH DOWN a= Q r U Q 1 WASTE WATER #3 AREA r r r r r SETTLING BASIN #5Elp LEGEND CHAIN LINK FENCE HEIGHT - VARIES OPEN DITCH DEPTH - 36" MAX. WASTE WATER SOURCE DURING RAINFALL BINS FORMED WITH CONCRETE BLOCKS OPEN END FOR LOADER OPERATION GRAPHIC SCALE 30 0 15 30 I INCH 30 FEET PROPERTIES OF WATER WEIGHT - 62.5 PCF WEIGHT - 8.33 PPG VOLUME - 7.5 GCF PH - 0 -14, 7 IS NEUTRAL w OR o N rn a� SIMMONS PROPERTIES DB 2640, PAGE 944 OCEAN ISLE BEACH SHALLOTTE TOWNSHIP BRUNSWICK COUNTY, NORTH CAROLINA JUNE 24) 2011 RESUBMITTAL o w� N a U zm w� w 14- t� Z w N o rn 0 X OLL ofw w z 0 0� w 0 r\ N 0) N d' 00 N z U U r; 0 W U U 0 vl A 0 0 04 0 00 Date: MARCH 15, 201 Drawn by: WED Checked by: WED Scale: 1" = 30'-0» Sheet No. W-4 !rlzo Cw� 00n Z ECM IMPERVIOUS DATA IMPERVIOUS AREA - 112,047 S/F TOTAL AREA OF PROPERTY = 3,99 (43,560) = 173,867 S/F PERCENT OF AREA IMPERVIOUSNESS = 112,047 / 173,867 = 64.4% DEED BOOK 2640 PAGE .,, N 2*32'16" E 674.71' 0 PUMP HOUSE RECLAIM ;FUEL : MATERIAL : B •. • . FUEL TANK. RIP RAP. :'BLUE ••SAND. CONEX' , TANK STONE.: : CABC SAND #67 :' #78 . DOT . :SAND; 43.4 SHE z CONCRETE RAMP' ci CONTROL • .. .. .. .. ' HOUSE PAR 243JA039 - CONVEYOR E. PANELS ZONED: 01 C-3�- :.. 3.99 ACRE ; °Nac 524.48' S 2'53'32" W w N L N :.' • % .. d OIB READY MIX CONCRETE, LLC 149.21' S 2'53'55" W RETENTION GRAPHIC SCALE 30 0 15 30 I INCH = 30 FEET ECM \£T pRA�NS w cq M N M 00 ------------------ LEGEND CHAIN LINK FENCE HEIGHT - VARIES OPEN DITCH DEPTH - 36" MAX. IMPERVIOUS AREA EXISTING CONCRETE PAVING JUNE 24, 2011 BINS FORMED WITH CONCRETE BLOCKS RESUBM(TTAL OPEN END FOR LOADER OPERATION SIMMONS PROPERTIES DB 2640, PAGE 944 OCEAN ISLE BEACH SHALLOTTE TOWNSHIP BRUNSWICK COUNTY, NORTH CAROLINA I Date MARCH 15, 2011 Drawn by: WEII Checked by: WE- 11 Scale: 1" = 30'—O"ll Sheet No. w 5 f • Y I I T i , .. �,t. .. �. .�� ..... ..!. '.'..�...�.. 1. ,.. Ili t. TO BASIN # 2 I.rf:BASINS J50. .................. , 3, 4 AND W3 CAPACITY = (50')(25')�3')(7.5 GCF) = 28,125 GALS WITH 12 FREEBOARD 2" SECTION S-1 NTS HOLDING BASINS WITH 12" FREEBOARD HOLDING BASIN #1 - 1Ox 40x 4)Q,5 G/CF) = 12,000 GALS HOLDING BASIN f - 50'x 25'x 3) 7.5 GPCF 28,125 GALS RECYCLE BASIN - 50'x 25'x 3')(7.5 GPCF) = 28,125 GALS WASHDOWN BASIN #4 - (50'x 25'x 3)(7.5 GPCF) = 28,125 GALS RECYCLE #5 - (24'x 25'x 3 'x 0,5')(7.5 GPCF) = 7,031 GALS RETENTION BASIN #6 - (25'x 150 x 3)(7.5 GPCF) = 84,375 GALS TOTAL CAP. ALL BASINS 187,781 GALS 10 YEAR STORM, 24 HOUR RAIN FALL = 6.94 INCHES ® LAT. 33' 54' 20" N, LONG, 78' 27' 39" W. http://hdsc.nws.noaa.gov/hdsc/pfds/: 3.99 ACRES = (43,560 S/F)(3.99) = 173,804.4 S/F 173,804.4 S/F (6.94/12) = 100,516.9 OF OF RAINFALL 100,516.9 OF OF RAINFALL (7,5 G/CF) = 753,876.6 GALS PER 24 HOURS ASSUME "C" = 0.85, Q = 0.85(753,876.6) = 640,795.1 GALS. RAINFALL WASTE WATER CREATED BY RAINFALL 15,900 S/F STOCK PILES 6,618 S/F PLANT OPERATIONS 1,250 S/F WASH DOWN AREA 23,768 S/F RECEIVING 7 INCHES OF RAINFALL 23,768 S/F ( 7/12 ) = 13,864.67 OF OF RAINFALL 13,864.67 CF OF RAINFALL (7.5 GPCF) = 103,985 GALS * DATA FROM SHEET W-4 unl nlKlc ReclKl Ji ELEV. 28.0 --/ BASIN # 1 POI NNI(` RACIAI A0 tLtV. Lt5.0 - BASIN # 2 N()l I11Nr RACIAI 40 --"" -"- LLL.V. LV.V BASIN # 3 BASIN # 4 ­_ BASIN # 6 SECTION S-2 NTS N 2' 32' 16" E 37' 674.71' 72 DETENSION BASIN - #6 37 WASTE WATER CAPACITY = (150')(25)(3')(7.5 GCF) = 84,375 GALS WITH 12 FREEBOARD 12" FR SECTION S-3 NTS DEED BOOK 2640 411&11 PAGE 944 498f L F 15" 1 20 CPP HOLDING BASIN - #1 T z: "'�_ _______ 10'064' - 12,000 GALS 33' --- _-- ____=-__— - - - - - - - - - �� +EMMAWcai -f. EL=320�42� CPp iiiii ---_ \�>> �' _-_-_-_--_----_`\�\ �"�., •l.! PUMP HOUSE ROCK DAM / FABRIC IIIII IIIII I l��l� 25' - 11111 HOLDING BASIN - #2 25" I IIIII I `� IIIII 28,125 GALS I i l l l I IIII f�,..=�R +Ilili IIIII I IIIII 10' WEIR IIII IIIII EL.=28.0 + IIIII I IIIII E.L.= 31.0 1111 full IIIII I IIIII IIII . 50, 6" _ )LP ,;�� IIIII IIIII � �ICP IIII I �1'11r- 28.0 IIIII I 11111 EL.= IIII I �.�-----------�' liin I IIt((�--- 25,---�\\� � il;l1 EL = 3075 hill 11111 1 BASIN NOTES I 11 III • ALL BASINS SHALL HAVE 3 1 SIDE SLOPES IF SOILS WILL PERMIT. j IIIII I I 6"_CPP i i; i I 11 I • BASINS #2, #3 AND #6 WILL BE PIPED AND VALVED TO COMPLETELY DRAIN. I iiiii _ I + _ 717� r iiiii • SILT FENCE AT BASINS #1 AND #5 WILL BE INSPECTED WEEKLY. ANY I iiiii EL.= 28.0 I I IIIII ACCUMULATION OF MATERIALS WILL BE REMOVED IMMEDIATELY. I 1 i I I LI o WATER IS TO BE PIPED FROM RECYCLE BASIN #3 TO THE OVERHEAD STORAGE TANK. STAND-BY WELL WATER IS AVAILABLE IF RECYCLE WATERS I +IIII M IIIII IIII 1 ARE NOT AVAILABLE 100% OF THE TIME. ' IIIII ' I I PUMP 11111 EL•= 28.0 IIIII i IIIIIc, _z I I IIII a RETENTION BASIN #6 WILL ONLY WORK WHEN THERE IS ENOUGH STORM I IIIII � � I I _ I l l I IIIII I WATER AVAILABLE TO FILL THE BASIN. t I IIII N i i i i I I i l I I • THE FORTANS ph CONTROL AND MONITORING SYSTEM MAY NOT BE REQUIRED. Hill I IIIII illfl � dill IIIII I ( IIIII � IIIII r 1 'IIII IIIII I IIIII IIIII 1 i EL.= 31.0 IIIII IIIII !IIII I 1 I hill Illll I 1 I I II M f IIIII IIIII IIIII I IIII, I =F_::`5-11 I 1 iiiii"' IIIII a 1 IIIII NAM j � I j ;iiii M � 3 0o I111I I _ I 'III cc�� IIIII ( II�If 25' I IIIII IIIII I I i�l IIIII I Hill IIIII i 1 IIIII IIIIII I IIIII EL.= 28.0 IIIII 1 IIIII IIIII � 1 I!i ' IIIII i IIIII IIIII 1 1 EL.-_ 31.0 IIIII U, I IIIII � Ulil i 1 it II I c~i�i I IIIII � IIIII 1 1 'I'i - II I !IIII I � IIIII II I m 91 iiiii 4� z 1 11111.. 8 3 IIIII I 1 IIII' iillli I a 1 11111 0 � � 11111 1 IIIII I I hill U-)-co IIIII I j III!! hill I I IIIII 3 "' Bill 1 1 IIII! IIIII I IIIII IIIII 1 , IIII . IIIII i IIIII IIIII I 1 Ilii; M IIIII I I IIIII IIIII I 1 IIIII IIIII I Hill IIIII I 1 IIIII EL.= 28.0 IIIII I I IIIII IIIII I 1 il!!i IIIII I TO BASIN # 3 i iiiii iiiii I iiiii hill IIIII I � IIIII iiii) I Bill 1 1 Ilili I Illil �I�II i 1 IIIII IIIII I 1 I OVERHEAD RECYCLED I I WATER STORAGE TANK I _ _ ► - - - --t- - _ _ _ _ _ _-� i 124' I ( IIIII I U I I I_ IIII ROOK "V'+ p11CH �� I I I N III I �` I o rn co III] DISCHARGE �- logoogogmEa n1 N1 NI 1111 NEW PLATFORM I I Hill I I f I I IIII SETTLING 1 i 1 I I I1111 1 ` BASIN #5 I ' _ _ CHARGE LEGEND CONTOURS --------- EARTH OR ROCK BERM AS REQUIRED :__> :> __:> ::�> EIP ECM + EL.=30.0 NEW SUBMITTAL --- I U UU� H U �-7 z� 0 W U U 0 n A LTJ a a 0 a 0 04 PP 0 04 00 r-1 E ............... s S /ON°°�` "M U w z 0 z A W 0 a 0 a Date: JUNE 241 2011 Drawn by: WED Checked by: WED Scale: 1" = 30'-0" Sheet No. w-6 4� NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director Mr. Wilbur E. Dees OIB Ready Mixed Concrete P.O. Box 6965 Ocean Isle Beach, NC 28469 April 13, 2011 Subject: General Permit No. NCG060000 OIB Ready Mixed Concrete 1581 Loblolly Lane Return # 2171 Brunswick County Dear Mr. Dees: Dee Freeman Secretary The Division of Water Quality received your application on March 22, 2011 for an Authorization to Construct a wastewater treatment system (associated with permit NCG140403). After review of the submitted material, we must return your application as it is deficient in significant supporting information. Please ask your engineer to contact me for an explanation of minimum submittal requirements. The submittal is deficient in the following particulars (although this is not necessarily an exhaustive list as a complete review of your application was not able to be performed): 1. Inadequate Design Basis and Site Plans: You have applied for an Authorization to Construct treatment or recycle facilities. North Carolina rules require DWQ to conduct an engineering review of your application. In reviewing any permit we evaluate engineering calculations to predict compliance with permit limits. The following issues were present: a. You have not included sufficient design calculations or technical narrative in your submittal. Your engineer must provide sufficient calculations and technical narrative details to show how your site wastewater treatment system will adequately treat wastewater from your site to acceptable Ievels, in order to meet permit limits. Please include these on separate sheets from the site plans. Necessary details are (but are not limited to): method of determination of storm and storm sizing, rainfall design storm, treatment cell sizing, reason for choosing design storm size, dimensions for calculation of treatment cells, description of runoff coefficients assumptions, and if discharging, the settling calculations (including assumptions, methodology, equations and variables). If the permittee is not planning to discharge, include a clear narrative and Wetlands and Stormwater Branch One 1617 Mai! Service Center, Raleigh, North Carolina 27699-1617 NorthCarohna Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX; 919-807-64941 Customer Service: 1-877-623-6748 AaNrall'yIntemet: www.ncwaterquality.org Mr. Wilbur E. Dees r1a OIB Ready Mixed Concrete April 13, 2011 equations to demonstrate how holding cells and recycling shall take place to sufficiently contain and control all discharge. b. No grading, topographical elevations or lines (or their relationship of the elevation of the treatment cells to the surrounding area) outlines of stormwater and wastewater drainage areas, location of stormwater drainage areas and outfalls, runoff conveyance structures were shown on site plans. In order to verify calculations showing the amount of water flowing to your wastewater treatment facility, stormwater outfalls and off -site, these items must be added to your site plan. Please include them in all future submittals. c. No detailed diagrams of treatment systems were included. To verify treatment system size and design, a detailed diagram must be included in future submittals. In these details, the engineer must include show flow path, freeboard, side view and all other adequate and complete details to show the construction and design of the treatment system (this is not an exhaustive list). Please specify the material (e.g., cement, liner, compacted earthen basin, or other?) for the construction of wastewater treatment cells and include additional storage depths for settled solids that would accumulate in cells. Describe these details in the narrative to be included in the next submittal. d. Stormwater and wastewater outfalls are not shown on site plans and are not numbered. Please include in your next submittal. e. Adequate stormwater topographical features are not properly shown, nor how those features affect drainage. There are no topographical features shown delineating sub - drainage areas (for instance sub -drainage areas 2 and 3), such as break-points at physical areas on the site. 2. Incomplete Submittal: a. The legal name of your site appears to be "OIB Ready Mixed Concrete, LLC". Please include your exact company name on submittals as it is registered in North Carolina. DWQ must have this name as it appears in the company registration to the North Carolina Department of the Secretary of the State. b. You must include documentation of your submittal for an Erosion and Sedimentation Control Plan application to the NC Division of Land Resources. Because of the above deficiencies, DWQ must return your application submitted as such. An exhaustive list was not able to be produced, however, please review the above deficiencies and have your engineer review contact me regarding submittal requirements. Mr. Wilbur E. Dees . 01B Ready Mixed Concrete April 13, 2011 If you have any questions concerning this application, please contact me at telephone number (919) 807-6379 or.jennffer.iones@ncdenr.gov. Sincerely, Jennifer ones cc: Wilmington Regional Office, Linda Willis Central Files Stormwater Permitting Unit Files STORMWATER PERMITTING UNIT DIVISION OF WATER QUALITY 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 AUTHORIZATION TO CONSTRUCT PERMIT REQUEST OIB READY MIXED CONCRETE PO BOX 6965 1581 LOBLOLLY LANE OCEAN ISLE BEACH, NORTH CAROLINA 28469 MAR 2 2 2011 C ENR - nAn «n 71Fi QU Nc� PM WILBUR E. DEES, P.E., P.L.S. CONSULTING ENGINEERING AND LAND 2927 MIDDLESEX ROAD FAYETTEVILLE, N. C., 28306 PHONE 1 FAX (910) 425-1941 CELL (910) 624-4779 REQUEST FOR ATC INDEX COVER SHEET INDEX APPLICATION SHEETS 1-5 EXHIBIT I - DIRECTIONS TO PLANT SITE EXHIBIT II - MERITECH, INC - it ANALYSIS EXHIBIT III - ENVIRONMENTAL CHEMIST, FACILITY LOCATION SHEET BRUNSWICK COUNTY MAP PLANT NARRATIVE - 3 SHEETS CONSTRUCTION NARRATIVE - 3 SHEETS DRAWING SHEET W-1 DRAWING SHEET W-2 DRAWING SHEET W-3 DRAWING SHEET W-4 SURVEYING OF SAMPLES INC. DATA NCDENR North Carolina Department of Environment and Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director January 7, 2011 Mr. Daniel Simmons OIB Ready Mix 1581 Loblolly Lane, 70 fox 696s Ocean Isle Beach, NC 28469 Natural Resources Subject: General Permit No. NCG140000 OIB Ready Mix COC No. NCG140403 Brunswick County Dear Mr. Simmons: Dee Freeman Secretary In accordance with your application for a discharge permit received on December 9, 2010, we are forwarding herewith the subject certificate of coverage (COC) to discharge under the subject state NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007.(or as subsequently amended). The Division acknowledges that temporary wastewater measures have been installed at this existing facility until a properly designed wastewater treatment facility can be designed, approved, and installed. The proposed future construction, installation, or modification of wastewater treatment facilities (including process wastewater recycle systems) will require ad Authorization to Construct (ATC) prior to construction per 15A NCAC 2H .0138 & .0139. The design information must demonstrate that the proposed treatment system will be able to meet permit conditions and effluent limits as required in the permit. You must submit, in triplicate, plans/specifications and design calculations, stamped and sealed by a professional engineer, with a letter requesting an ATC to the Stormwater Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Also, a design narrative must be included that tells us specifically how the stormwater and wastewater flows will be generated, collected, conveyed, treated, and discharged. This requested information should be received by this Office prior to April 4, 2011. Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water Quality, The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or Wetlands and Stormwater Branch One 1617 Mail Service Center, Ralegh, North Carolina 27699-1617 NorthCarol i na Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 )Vatlfmlly Phone: 919-8-807-63401 FAX 919�07-6494 L Customer Service; 1-877-'i236748 Internet: www,ncwaterquality.org An Equal Opportunity 1 Aifirmabve Action Employer Mr. Daniel Simmons OIB Ready Mix NCG 140403 January 7, 2011 permits required by the Division of Land Resources, Coastal Area Management Act or any other federal or local governmental permit that may be required. if you have any questions concerning this permit, please contact Robert Patterson at telephone number (919) 807-6375. Sincerely, ORIGINAL. SIGNED BN KEN PICKLE for Coleen H. Sullins CC' Wilmington Regional Office, Linda Willis Central Files Stormwater Permitting Unit Files Page 2of2 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140403 STORMWA`I'ER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, OIB Ready Mix is hereby authorized to discharge stormwater and process wastewater from a facility located at OIB Ready Mix 1581 Loblolly Lane Ocean Isle Beach Brunswick County to receiving waters designated as an UT to-Jinnys Branch, a class C; Sw water in'the Lumber River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, III, IV, V, and VI of General Permit No. NCG 140000 as This certificate of coverage shall become effective January 7, 2011 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this 7`h day of January, 2011. ORIGKM-S �CK� foi- Coleen H. Sullins, Director Division of Water Quality By the Authority of the Environmental Management Commission A' ` ,� rl��l ': M � .��r-'t ice' • �� - ' � eo�r'� �`� i` `_�' •\ 'f'�'(�� �,'•` I r tt r.1 _ ^J � ��F�'. `i�'J�s�'i'/i' ,�< -���_� .14 u�ttf 11 1d,1�1 JJ \• r'Lri` rr;;%�i" �� 1 � _^� ' f • Itiles- s-i!S/• �.- .r - - - ./�', _ 1. `'i. �/=� j r��+ . �: I ' • �-��/.r% 1 : , - '� x _ (•', . Ar- . ;r ��--' �- '• � l rt.; � �rfi` JI . q�{' rl' �r't f t •i • .� . _� 1������J - �., � •� . � \: ' \ �~ 1' 1. � ��, _�...�... �•• ��1.•-' •~r�'•- �� +tom - r� .�_-JO - � •F I �%`�'u `'-/I..i._. j�J~-�.� ? t J '1 C C� l , �� It � J�1` =�. 1 \i'`__'J1 J i_ _--�� r r: i. � w�- F -',�� • 4 Pik: W,1� " • __ _ � �='3'._�� .._... .-„ f� 3{ _' Y� ci �� �J// f •' - _ JT - S�t,.:� '� � ti"PaQR B' 1 X �/_.%-` S _ or ' f �•��.-. / ��rfaRIt. � �: -� 1 �, ; r• ✓l -r -�: J -7Lti .f. -��' J ' �f� ra .. __ _ _ ,Fa'.� r�r/_J ! 1 e J --• � V / C 'LS�6 II i% �•O f� ''1` l I 1 i/ i -, - i � � � � +�• •� `1 � ` • lr , � /~ u 1 i, �- -�-��y'Y- J�k�l�)%� i lli :i".. 1. i 1 • � .•N_., f . 1 .--. fl �.�� � t, • I�l�� � '�+ I rfsy r: ----�— - OIB Ready Mix =1 ,'� s, �4,•',,1 '• x.; 5 S- `_� ' .,.• 1 : �---�� . _ ,.. • j j� ��r---"- Cerrr`-�-_ � 2� �� 1 ; � l;,rt i` i , _j / i .t+-�',r•,'�• _ � ice. Jr:' 1.,�~�:��-:.- ` .y�.a:�. :ry�,�,�__---., `��!-•=i . � _ i • j i •• ��>� ,.. - tr•:• , ✓ ,, ij�i � - i"'-' ' • � )'� C;�4_ _�. _ � - r SttE 'r i YP •�+ :lam -1•. tip' �%� ''L .f It{��r'i' �''" Y� \ ( S k: •'Y mot• •�.�. � _�` -4.r �r i �v�--�.- �-�f... ,'1`, F`, 1 t._ • mod, S• t'. }\ " U^ 1 .G, • ----�T-_-�•r- IT -11• i - r 1.."-• •` "�� -,!,'r _- �1 1 i ., f = \ �7"`„ram �`'�, .�, "'Li: a• __.(�: •,r .--- . � .f � ... - �' � 5 -� .. ram,.- �, ► - VET � • - '. - -- _ --,j] ..�, _ � � - -- �If \ t'• ',!. .-• /E,-z 1':.�_iliY f' a���+-' k _I-.Jk�''r �' ✓-�ty�`', • or' � �_' -car � �"•'�' � ti.-j .� i�, :!�"`l,. .'.E W_ � , �'� err '" -��, �."� �� � rp.•.��•� � NCG140403 N w*E S Map Scale I : 24, 000 OIB Ready Mix Latitude: 331 54' 2011 N Longitude: 780 271 39" W County: Brunswick Receiving Stream: UT to Jinnys Branch Index No.: 15-25-2-16-1-(1) Stream Class: C; Sw Sub -basin: 03-07-59 (Lumber River Basin) Facility Location M)SO ®�� NCDENR f.��R]Tv�rt un. N`]lyu QnQ�MlS NOTICE OF INTENT Division of Water Quality / Surface Water Protection National Pollutant Discharge Elimination System NCG140000 FOR AGENCY USE ONLY Dme Received Year I Mon01 Dxv ccnifiome arcv.ely CMck x Amoum 3 IRYI ASSI 10 rye National Pollutant Discharge Elimination System application for coverage under General Permit NCG140000: STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with activities classified as: SIC (Standard Industrial Classification) Code- 3273 Ready Mixed Concrete For new plant sites that will discharge or recycle process wastewater (even if commingled with stormwater): This NOI is also an APPLICATION FOR Authorization to Construct (ATC) wastewater treatment facilities. ATC requests must be submitted at least 90 days prior to construction'. For existing plant sites discharging or recycling process wastewater (even if commingled with stormwater): This NOI is also an APPLICATION FOR Authorization to continue to operate wastewater treatment facilities in place. Construction, modification, or installation of any new treatment components at an existing site requires an ATC. Treatment facilities used to treat or recycle process wastewater (including stormwater BMP structures treating process wastewater flows commingled with stormwater).require an ATC prior to construction per 15A NCAC 2H .0138. The authorization to construct or continue to operate will be issued at the same time as the Certificate of Coverage (COC) for the NCG 14 permit. Design of treatment facilities must comply with requirements of 15A NCAC 21-1.0138 & .0139. Construction of wastewater treatment facilities (this includes recycle systems) at new or existing plant sites requires submission of three (3) sets of plans and specifications signed and sealed by a Professional Engineer (P.E.) or qualified staff along with this application. A copy of the design . calculations should be included. Please see questions 14 & 15. o For questions, please contact the DWO Regional Office for your area. (Seepage 5) (Please print or type) 1) Mailing address of ownerloperator (address to which all permit correspondence will be mailed): Name Street Address City Telephone No. 2) Location of facility producing discharge: Facility Name Facility Contact Street Address City County Telephone No- U State V( ZIP Code e! ell/ y Fax: /J .:-T < - Ll1_ 9 State tiC— ZIP Code /o - -7S - =l Z 7.3 ' Fax: 5 /v t As per 15A NCAC 2H Page 1 of 5 (.0706 � ill Unless treatment facilifies are designed, constructed, and put into operation by employees internal to the company who are qualifi perform such work for their respective companies in accordance with General Statutes, 89C-25 (7), plans and specifications must b �V4.E.� and sealed by a P.E. L S W U-229-071408 Last revised 7/14108 i NCG 1 40000 N.O.I. 3) Physical location information: Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). ',0 _4r -- f It ,. 7 .S_� ,(. ,- �, I �� .?T�. r CfL', i`d� . I w .. i�a:: Lr 1✓'r ..i ✓-, h Y (A copy of a county map or USGS quad -sheet with facility clearly located on the map is a required part of this application.) 6 � 4) Latitude —3 St ZO. 21 Longitude 'I -d� 2 7'-2'?. 4 725 (deg, min, sec) 5) This NPDES Permit Application applies to which of the following: I� New or Proposed Facility If Date operation is to begin _A =+J (7 !�o "K~� Existing 6) Standard Industrial Classification: Provide the 4 digit Standard Industrial Classification "Code (SIC Code) that describes the primary industrial activity at this facility SIC Code: -I 7) Provide a brief description of the types of industrial activities and products produced at this facility: (includea site diagram showing the process areas present at this facility.) ( 8) Discharge points 1 Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater and/or wastewater from the property? , "%".4__,.,.- What is the name of the body or bodies of waterl(creek, stream, river, fake, etc.) that the facility stormwater and/or wastewater discharges end up in? k.._« -t _ If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e-g. City of Raleigh municipal storm sewer). I' -,. Receiving water classification (if known): 1,_' I,A:- Note: Discharge of process wastewater to receiving waters classified as WS-11 to WS-V or SA must be approved by the N.C. Dept. of Environmental Health. If DEH does not approve, coverage under NCG140000 cannot be granted. No new discharges of process wastewater are permitted in receiving waters classified as WS4 or freshwater ORW. 9) Does this facility have any other NPDES permits? LJ No .1 ❑ Yes If yes, list the permit numbers for all current'NPDES permits for this facility_ 10) Does this facility have any Non -Discharge permits (ex: recycle permits)? Q'No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 11) Does this facility employ any best management practices for stormwater control? ❑ No D'Yes If yes, please .- rr 5 W U-229-071408 Page 2 of 5 Last revised 7114J2008 NCG140000 N.O.I. 12) Does this facility have a Stormwater Pollution Prevention Plan? l� El Yes If yes, when was it implemented? 13) Are vehicle maintenance activities occurring or planned at this facility? "o ❑ Yes Wastewater Treatment Design Information 14) Are discharges occurring or planned from any of the following process wa, Vehicle and equipment cleaning 2'�es ❑ No Wetting of raw material stockpiles a-5 es ❑ No Mixing drum cleaning I9-'Ves ❑ No If yes to any of the above, please describe the type of process ysed to treat and/o wastewater_ — For a sufficient application, you must provide design specifics (e.g., design volumf area, etc.) and calculations to demonstrate compliance with permit effluent limits ( Suspended Solids (TSS) — 34 mg/l, and Settleable Solids (SS) — 5 ml/l.) [Use sep� If all these discharges are recycled, please refer to Question 15. — �� ° For plants that rec cle and/or dischar a rocess wastewater. When applying for this permit, you are also applying for an authorization treatment facilities) or authorization to continue to operate (existing treai part of the NOI. For new sites, you must submit three (3) sets of specifications with this application and provide supporting calculat compliance of final discharge with permit limits. For existing sites, applica three (3) sets of plans and specs for facilities as -built and provide as man] possible, or submit a detailed diagram of treatment systems in place that in. such as tank volumes, dimensions, retention time, piping, settling basin deti Please note: ff new treatment systems are planned for an existing site, an A' prior to construction of those facilities. Plans/specs/calculations prepared request for an ATC may be submitted with this NOI, or separately at a late request the status of your plans for requesting an ATC upon issuance of the 15) Does the facility use or plan to use a recycle system? C3El 'Yes If yes, what size storm event is the system designed to hold before overflowing? (fc year, 24-hr rainfall event o For a recycle system (regardless of when rt overflows), please provide plans, calcul specifics (e.g., throughput assumptions/water balance, design volume, retention tirr freeboard in design storm event, etc-). [Use separate sheet(s)]. ' For a sufficient application, the information must demonstrate compliance of final di effluent limits (pH — 6-9 SU, Total Suspended Solids (TSS) — 30 mg/l, and Settleabl must demonstrate that the recycle system has sufficient capacity to contain runoff fE rainfall event pfus one foot of freeboard under design operating conditions. Page 3 of 5 5w ll-229-07140a NCG140000 N.O.i. 12) Does this facility have a 5tormwater Pollution Prevention Plan? ❑ Yes If yes, when was it implemented? 13) Are vehicle maintenance activities occurring or planned at this facility? "o ❑ Yes Wastewater Treatment Design Information 14) Are discharges occurring or planned from any of the following process wastewater generating activities? Vehicle and equipment cleaning D-"�es ' ❑ No Wetting of raw material stockpiles 13-les ❑ No Mixing drum cleaning 19'fe's ❑ No If yes to any of the above, please describe the type of process sed to treat and/or recycle the process �--- wastewater.- WC-'-U-W--" ; s � � �-� � c��."r }, t ,_asp. ,< , : , For a sufficient application, you must provide design specifics (e-g., design volume, retention time, surface 'W4� area, etc.) and calculations to demonstrate compliance with permit effluent limits (pH — 6-9 SU, Total Suspended Solids JSS) -- 30 mg/l, and Settleable Solids (SS) - 5 ml/l.) [Use separate sheet(s)j.l if all theca dicrharnec era rPrVrlr ri nleaca refer to 01 iactinn 1 r, t`" " G' F" Z -( 0 For plants that recycle and/ar discharge process wastewater. - When applying for this permit, you are also applying for an authorization to construct (new treatment facilities) or authorization to continue to operate (existing treatment facilities) as part of the NOi. For new sites, you must submit three (3) sets of design plans and specifications with this application and provide supporting calculations that predict compliance of final discharge with permit limits. For existing sites, applicants should submit three (3) sets of plans and specs for facilities as -built and provide as many design details as possible, or submit a detailed diagram of treatment systems in place that includes information such as tank volumes, almensions, retention time, piping, settling basin details, etc. Please note: If new treatment systems are planned for an existin-g site, an ATC will be required prior to construction of those facilities_. Plans/specs/calculations prepared by a P.E. and the request for an ATC may be submitted with this NOI, or separately at a later date. DWO may request the status of your plans for requesting an ATC upon issuance of the COC. 15) Does the facility use or plan to use a recycle system? ❑ No 9_1_y� es If yes, what size storm event is the system designed to hold before overflowing? (for example, 10-yr, 24-hr) year, 24-hr rainfall event C,{ r, .��V �= Q. f`; For a recycle system (regardless of when it overflows), please provide plans, calculations, and design specifics (e.g., throughput assumptions/water balance, design volume, retention time, surface area, amount of freeboard in design storm event, etc.). [Use separate sheet(s)]. IFFor a sufficient application, the information must demonstrate. compliance of final discharge with permit 4A effluent limits (pH - 6-9 SU. Total Suspended Solids (TSS) - 30 mg/I, and Settleable Solids (SS) - 5 m1/1), or must demonstrate that the recycle system has sufficient capacity to contain runoff from a 25-year, 24-hr rainfall event plus one foot of freeboard under design operating conditions. Page 3 of 5 SWU-229-071408 Last revised 7i1412008 NCG140000 N.O.I. 16) Are wastewater treatment facilities (including recycle systems) planned in the 100-year flood plain? t� No ❑ Yes If so, include information to demonstrate protection from flooding. (Minimum design requirements for treatment works include protection from the 100-year flood, per 15A NCAC 2H .0219_) 17) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? PhiNo ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? 2 No ❑ Yes c) is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of ;N' rdous waste? o ❑ Yes d) If you answered yes to questions b_ or c., please provide the following information: Type(s) of waste: How is material stored:_ Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor: _ Vendor address: 18) Certification: North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a materiai fact in a ruiernaking unx eedirry ur curries to i;ese under 11,is A.—ocle; or Who Ralsifics, tam,pars renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the (Environmental Management) Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Title; (Signature of Applicant) (Date Signed) Notice of Intent must be accompanied by a check or money order for $100.00 made payable to: NCDENR Page 4 of 5 SWU-229-0*71408 Last revised 7/14/2008 NCG140000 N.O.f. Final Checklist This application will be returned as incomplete unless all of the following items have been included: Check for $100 made payable to NCDENR. R' This completed application and all supporting documentation (including design details and calculations for treatment systems). ❑ If an Erosion & Sedimentation Control (E&SC) Plan is required from Division of Land Resources (DLR) E or local designee: documentation verifying applicant has developed and submitted that Plan to the governing agency (required per 15A NCAC 02H .0138)- 1�C� For new sites (or sites that will install new treatment facilities): Three (3) copies of plans and specifications for wastewater treatment facilities (including recycle systems), signed and sealed by a Professional Engineer or qualified staff meeting requirements of G.S. 89C-25 (7)- ❑ For existing sites: three (3) copies of plans and specifications for wastewater treatment facilities (including recycle systems) as built, stamped and sealed by a Professional Engineer, or (only if plans not available) a detailed diagram of treatment systems in place that includes information such as tank volumes, dimensions, retention time, piping, settling basin details, etc. f s_ i'.3 E3' A site map showing, at a minimum, (existing or proposed): So �' = `. r t' { ate: c C•a.. I„c of �r , i (a) outline of drainage areas, (b) stormwater/wastewater treatment` structures, (c) location of stormwater/wastewater outfalls (corresponding to which drainage areas), (d) runoff conveyance structures, (e) areas where materials are stored, (f) impervious areas, and (g) site property lines. Q A county map or USGS quad sheet with location of facility clearly marked. — L : J w ; { I ; U Mail the entire package to: l: 4 v� i Stormwater Permitting Unit L� < Division of Water Quality- 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of an NPDES permit. For questions, please contact the DWO Regional Office for your area. DWQ Regional Office Contact Information: Asheville Office ------ (828) 296-4500 Fayetteville Office --- (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office ..--.....(919) 807-6300 +,..:ram ` ,'iImin91on Page 5 of 5 sW U-225-071408 Last revised 7/14/2008 1531 Loblolly Lane Southwest, Ocean Isle Beach. NC - Google Maps - Page I of I F-i n, V G1� t Address 1581 Loblolly Ln SW Notes ' � C.i m r } S Ocean Isle Beach, NC 28469 .. 1 Ln < r, z Cn — y S Cr f1f 1T9 F c S i _+ _ J �r '> L7 s J lt� C- 02010 Gnogte - Map data 02010 Google -, i Page 1 of 1 Brunswick County 2009 N ' f �() Freeland I '�hafio'.t= [ t , NalC�cn ' r J=coni5fc f -�a�h S1;nset : fir_ CSXAR-�i�i `�- f'.. -and �3�r. Lei an J f t � � t 4 � , 1 inn�lZc, . cY v , -e Z I =lt i nft and 414! l Lr 1JL C-ZSLjin 01B Ready Mixed Concrete PO BOX 6965 1 G 1581 Loblolly Lane .�' 15a Ocean Isle, NC 28469.M a -�. 0 R -4f)Y MIXED CQNICREj Date: Thursday, December 02, 2010 To: NCDENR Office: 910-796-7343 127 Cardinal Drive Fax: 910-350-2004 Wilmington, NC 28405-3845 PHONE: (910) 575-HARD (4273 ) FAX: (910) 575-4293 Ref: OIB Ready Mix --Water Treatment Facility Design I have spoken with Linda Willis of NCDENR to obtain information regarding what areas must be incorporated into the calculations for design of our retention/recycling basins on site. Our intent witl be to contain and recycle 100% of the waste water on site -once they are in place. 1 have also contacted a registered engineer, Grady Simmons Jr., who has been retained to assist me in the design and calculations of the retention basins. Please consider this correspondence as proof that we are diligently working on creating plans and specifications for our waste water treatment as require by this Notice of Intent Application., These documents are being expedited and will be forwarded to NCDENR very shortly. Sincerely, Vie s&Vmo"