Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG140381_MONITORING INFO_20181026
STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. �V CiCa /L-J 6 3 aOCTYPE ❑HISTORICAL FILE f� MONITORING REPORTS DOC DATE pQol DO YYYYMMDD l C PROCESS WASTEWATER -- Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COY,�RAG NO. CG14,e) � f/ FACILITY NAME. k / PERSON COLLECTING SA LES• CERTIFIED LABORATORY/ / ab # / Z Lab # LIMIT VIOLATIONS? YES ❑ NO P• Part A: Wastewater Monitoring Requirements SAMPLE COLLECTION YEAR: SAMPLE QUARTER: - ®!ul-Sept ❑Oct -Dec ❑Jan -Mara COUNTY: PHONE NO. (_L4)��-��� ADD TO LISTSERVE? []YES [-]NO EMAIL: DISCHARGING TO CLASS. ❑SA ❑HQW ❑PNA ❑Trout OPTIONAL INFO: ❑April -June ❑Other __ _, Outfall No. Date Sample Collected' (mrn/dd/yr) Type of Wastewater z (VE, RM, MD) pH (standard) Total Suspended Solids (mg/L) Settleable Solids (MLA) TPH usingDischarge method 1664A SGT-HEM' (mg/L) Duration (minutes) Total Flow 7 (gallons/day) - - - 6-93'4 303,5 53 (15)6 - - 12 �vvi�v-v• 1 If wastewater systems have not discharged in this quarter— report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. 2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. s If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. S TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 1of2 s Process wasater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but insterd is subject to benchmarks and provisions of Part 1V, Section A, including the Tiered Response Action. 7 Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ and the DWQ Regional Office may require an annual flow report on a case -by -case basis. MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY INCLUDING ALL "NO FLOW" "NO DISCHARGE" WITHIN 30 DAYS OF RECEIPT OF SAMPLE OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn-. DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS C£RTIFIC TION FOR ANY INF )RM TION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." ure of Perm Z7 ,G% - e /- (Da/tee Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 2 of 2 i STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING FORM GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 S Zt� 1 SAMPLE COLLECTION YEAR: 2 O ) -:� FACILITY NAME: C,60'�t,tjl'rt(U�SAMPLING PERIOD: ❑July Decernl�er [January June PERSON COLLECTING SAMPLES COUNTY t,,/� k� CERTIFIED LABORATORY�ac.f 1a(�nJA�tak;r:a Lab f# _ 417 PHONE NO. (1� 9 05�2 Z Lab # ^ ADD TO LISTSERVE? ES ❑NO EMAIL: OPTIONAL INFO: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout [JOtherC_ 4 Part A: Stormwater Monitoring Requirements Outfall No. Date Sample Collected (mo/dd/yr OR NO FLOW)' pH (Standard Units) TSS (mg/L) Event Duration (minutes) Total Rainfall4 {in) in Tier 2 Monthly Monitoring? (y/n) # of Months inTier 2 Sampling - 6-9z 100 - - Z- �. 3. s 1 -} N RECEIVED APR rl"AITF A F DWR : )ECTION 1 If "NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here. Please make sure to mark the sample period above. z If a value is in excess of the benchmark, or outside the benchmark range (for plI), you must }rnplement the Tier 1 or Tier 2 responses in the General Permit. Tier 2 Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range. 3 TSS benchmark values are 10C mg/I, except when discharging to ORW, HQW, Trout, and PNA waters where they are 50 mg/I. For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge. Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 1 of 2 `ter• Part B: Vehicle Maintenance Activity Monitoring Requirements for facilities using> 55 gal of new motor oil/month —averaged over a calendar year. Outfall No. Date Sample Collected (mo/dd/yr)' PH (standard units) TPH using method 1664A5GT-HEM (mg/L) Total Suspended Solids (mg/L) Event Duration (minutes) Total n Rainfall (in) New Motor Oil Usage (gal/month) In Tier 2 Monthly Monitoring? (y/n) # of Months in Tier 2 s Sampling 6-9 15 100 , - - - HAS YOUR FACI LITY HAD q OR MORE BENCHMARK EXCEEDEN AT ANYONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES ❑ NO HAVE YOU CONTACTED THE REGION? YES ❑ NO REGIONAL OFFICE CONTACT NAME: Mail Original and one coiov of this DMR (including all "No Flow" & "No Dischame" reports) within 30 days of receipt of sample for at end of monitoring period in case of "No Flow") to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST 51GN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible forgathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete am aware that there are ignifi ies or submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) ( ate) w Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/12 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 a 3 `-6 � SAMPLE COLLECTION YEAR: 20+ -�- FACILITY NAME: C.Ckplv�,i uo AV fA rl�W)- SAMPLE QUARTER: ❑Jul -Sept ❑Oct -Dec PERSON COLLECTING SAMPLES: COUNTY: WnAc--r- 99�r os�z [Jan -March []April -June CERTIFIED LABORATORY- t-Ar-& kNtJe-14j (A1 _Lab tt . ) Z PHONE NO. ( l k ) j D Lab # ADTO LISTSERVE? ❑YES []NO EMAIL: Va(' n C-Lie— 4�,72 LIMIT VIOLATIONS? YES ❑ NOR DISCHARGING TO CLASS: []SA ❑HQW ❑PNA []Trout 2'0therC ��Ii�Li]v_T�i►1 �i71 Part A: Wastewater Monitoring Requirements Outfall No. Date Sample i Collected (mm/dd/yr) Type of Wastewater RMMD) z (VE, , pH (standard) Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH usingDischarge method .1664A G SG /L) (mg/L} Duration (minutes) Total Flow 7 (gallons/day} 6-93,4 303,5 53 (15)6 - - - - Z- 1 Vr- IZw. rA 7 1 t 510 120 so Wit' t_ TW tir TRH ,, - .%��.1 1 If wastewater systems have not discharged in this quarter- report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. Z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring, pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8,5 S.U. for discharges to saltwaters. TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. Permit Date:7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 e Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. ' Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY_ (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO; Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware tF�at there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." J ature Wermittee) Permit Date: 7/1/201D-06/30/2015 (Date) Last Revised 07/13/11 Page 2 of 2 l NCDENR Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report Forguidance on filling out thisform, please visit: http://portal.ncdennorg/web/,,vq/ws/su/npdessw#tab-4 Permit No.: N/C/_/_/�/T/_/�/_/ or Certificate of Coverage No.: Facility Name: Capital Ready Mix Concrete Plant (Formerly Jenco Concrete Plant) County: Wake 4 _ Phgne No, all - ;_71.} _ o'Z Z Z Inspector: 11 Date of Inspection: M---q- Time of Inspection: _ 1: -45 _14 yvL APR 1 0 2017 Total Event Precipitation (inches): CENTRAL FILES DWR SECTION Was this Representative Storm Event" or "Measureable Storm Event" as defined by the permit? (see i rmation below.) Yes ❑ No Please verify whether Qualitative Monitoring must be performed during a "representative storm event" or "measureable storm event" (requirements vary, depending on the permit). Qualitative monitoring requirements vary. Most permits require qualitative monitoring to be performed during a "representative storm event" or during a "measureable storm event." However, some permits do not have this requirement. Please refer to these definitions, if applicable. A "representative storm event" is a storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than 0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no precipitation. A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DWQ Regional Office. By this signature, I certify that this report is ate and complete to the best of my knowledge: (Signature of Permittee or Page i of 2 SWU-242, Last modified 10/25/2012 1. Outfall Description: Outfall No. 1 Structure (pipe, ditch, etc.) Pipe Receiving Stream: Marks Creek Describe the industrial activities that occur within the outfall drainage area: Parking Area and Office/Maintenance Building 2. Color: Describe the color of the ditch (light, medium, dark) as descriptors: I IIc using basic colors (red, brown, blue, etc.) and tint 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): QQrJ ef _ 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 � 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 C) 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 (2 J 3 4 5 7. Is there any foatn in the stormwater discharge? Yes Na S. Is there an oil sheen in the stormwater discharge? Yes 9. Is there evidence of erosion or deposition at the outfall? Yes No 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 10/25/2012 STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING FORM GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE N. NCG14 Q 3 9 i FACILITY NAME: PERSON COLLECTING SAM ES —JOY CERTIFIED LABORATORY t� vzA r'Gw Lab # / Lab # OPTIONAL INFO: Part A: Stormwater Monitoring Requirements SAMPLE COLLECTION YEAR: �UJ� SAMPLING PERIOD: July -December ❑ January -June � COUNTY _ VA F� PHONE NO. (may`) •z /7 ` azzz ADD TO LISTSERVE? ❑YES []NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ❑Other, Outfall No. Date Sample Collected (mo/dd/yr OR NO FLOW)1 pH (Standard Units) TSS (mg/L) Event Duration (minutes) Total a Rainfall (in) In Tier 2 Monthly Monitoring? (y/n) # of Months in Tier 2 Sampling, O L4'✓/ Z 1 If "NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here, Please make sure to mark the sample period above. 2 If a value is in excess of the benchmark, or outside the benchmark range (for pH), you must implement the Tier 1 or Tier 2 responses in the General Permit. Tier 2 Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range. 3 TSS benchmark values are 100 mg/l, except when discharging to ORW, HQW, Trout, and PNA waters where they are 50 mg/I. 4 For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge. Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 is Page 1 of 2 C, Part B: Vehicle Maintenance Activity Monitoring Requirements for facilities using > 55 gal of new motor oil/month — averaged over a calendar year. - Outfall No. Date Sample Collected (mo/dd/yr)' pH (Standard Units) TPH using method 1664ASGT-HEM (mg/L) Total Suspended Solids (mg/L) Event Duration {minutes} Total Rainfalla (in) New Motor Oil Usage (gal/month) In Tier 2 Monthly Monitoring? (y/n) # of Months in Tier 2 Z Sampling 6-9 15 1oo - - - - - 0 y HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES AT ANY ONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES [—]NO [gill HAVE YOU CONTACTED THE REGION? YES ❑ NO REGIONAL OFFICE CONTACT NAME: Mail Original and one copy of this DMR (including all "No Flow" & "No Discharge" reports) within 30 days of receipt of sample (or at end of monitoring period in case of "No Flow") to, Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "1 certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Perm fz/GZ�/ (Date) Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 2 of 2 J PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT No. NCG140000 CERTIFICATE OF COVERAGE No. NCG14 O 3 -5-�, 1 FACILITY NAME: /W,/v/ 7r!•?c,r,'tz PERSON COLLECTING SAM LES: --o-c. 6' r'/b CERTIFIED LABORATORY: ,AcY vc >/ Lab # / Lab # LIMIT VIOLATIONS? YES ❑ NO ❑ Part A: Wastewater Monitoring Requirements SAMPLE COLLECTION YEAR: 701.6 SAMPLE QUARTER - ❑Jul -Sept Oct -Dec ❑Jan -March W COUNTY: A>� PHONE NO. (�) Z/ 7 0 ZT7, ADD TO LISTSERVE? ❑YES [—]NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA []Trout OPTIONAL INFO: []April -June []Other, Outfall No. Date Sample Collected' (mm/dd/yr} Type of Wastewater (VE, RIM, MD) pH (standard) Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH usingDischarge method 1664A SGT HEMS (mg/L) Duration {minutes} Total Flow 7 {gallons/day} - - - 6-93,4 30"' 53 (15)6 - - 0_ L /0 Zvi V V4 . 101 MP Alp N (J LS 1 If wastewater systems have not discharged in this quarter— report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. 2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 E p---1of2 6 Procej s wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall beset to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW")TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." ature of �re`rmittee) Permit Date: 7/1/2010-06/30/2015 LI I i 7� (Date) Last Revised 07/13/11 n__„2of2 STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING FORM GENERAL PERMIT No. NCG140000 CERTIFICATE OF COVPINI) AGE NO. NCG14 d 3 T I FACILITY NAME: c'm M,x 0',C� r PERSON COLLECTING SAMPLES s CERTIFIEDLABORATORY�j [)o0,It,trlLab# I TLab # OPTIONAL INFO: Part A. Stormwater Monitoring Requirements SAMPLE COLLECTION YEAR: 7-0 l Co SAMPLING PERIOD:DIuly-December COUNTY V J!1, k ti ❑ January -June PHONE NO. [ 9)'\ } r — 05'2Z ADD TO LISTSERVE? ES ONO EMAIL: V (,t Och �++r[vNc'� DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ❑Other_C4U5 l_,j Outfall No. Date Sample Collected mo dd (/ /Yr OR NO FLOW)' pH (Standard Units) TSS (mg/L) Event Duration (minutes} Total 4 Rainfall {in) In Tier 2 Monthly Monitoring? ly/n) # of Months in Tier 2 2 Sampling - 6-9 100 ' - - - 9 IV, Z �. SFfirl S 1 If "NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here. Please make sure to mark the sample period aboe`� If a value is in excess of the benchmark, or outside the benchmark range (for pH), you must implement the Tier 1 or Tier 2 responses in the Gene'rAal Permit. Tier 2 Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range. a TSS benchmark values are 100 mg/l, except when discharging to ORW, HQW, Trout, and PNA waters where they are 50 mg/I. For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge. Permit Hate: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 1 of 2 Part B: VerRde Maintenance Activity Monitoring Requirements for facilities using > 55 gal of new motor oil/month — averaged over a calendar year. Outfall No. Date Sample Collected (mo/dd/yr}1 PH {Standard Units} TPH using method 1664A SGT-HEM (mg/L) Total Suspended Solids (mg/L) Event Duration (minutes) Total , Rainfall (in) New Motor Oil Usage (gal/month) In Tier 2 Monthly Monitoring? (y/n} # of Months in Tier 2 2 Sampling 6-9 is 100 ' - - - - - o•- WAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENSES AT ANY ONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES []NO HAVE YOU CONTACTED THE REGION? YES ❑ NO E' REGIONAL OFFICE CONTACT NAME: Mail Original and one copv of this DMR (including all "No Flow" & "No Discharge" reports) within 30 days of receipt of samole (or at end of monitoring period in case of "No Flow") to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: N certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant pen ubmitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) Permit Date:7/1/2011-60/30/2015 (Date) Last Revised 7/13/11 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 6 SAMPLE COLLECTION YEA 1 FACILITY NAME: CaA-t,` LjG.i I�r C' �Gt'ihQi i 0� SAMPLE QUARTER: • ul-Sept []Oct -Dec ❑Jan -March ❑April -June PERSON COLLECTING SAMPLES: Lt9 51.,, O V" COUNTY: CERTIFIED LABORATORY: r i �E.�h�Lab # 1 Z PHONE NO. [ r71 � j 9 5 4 —7 ` Lab # ADD TO LISTSERVE? DfES []NO EMAIL:Vj rl� ChAe,� 1 fEajtym,x concr c • '' LIMIT VIOLATIONS? YES ❑ NO ❑ DISCHARGING TO CLASS: [:]SA ❑HQW ❑PNA ❑Trout 20ther. C'j )QS, ) OPTIONAL INFO: Part A: Wastewater Monitorins Requirements Outfall No. Date Sample Collected' (mm/dd/yr} Type of Wastewater (VE, RM, MD)' pH (standard) Total Suspended Solids (mg/L} Settleable Solids �A(mL/L} TPH usingDischarge method 1664A 6 SGT-HEM (mg/L) Duration (minutes) Total Flow � {gallons/day} 8-93'4 ` 303,5 P� h,11 53,, (15)6 - - 2 4'9,,,J Nn�� dP ZO U l U / If wastewater systems have not discharged in this quarter— report "No Flow" or "No Discharge' here. Please make sure to mark the sample quarter above. 2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. ° pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TS5 limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 e Process was;c-water discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY INCLUDING ALL "NO FLOW" "NO DISCHARGE" WITHIN 30 DAYS OF RECEIPT OF SAMPLE OR AT END OF MONITORING PERIOD 1N CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware thayl�here are significant penalties for submi se4nformation, including the possibility of fines and imprisonment for knowing violations." // (Date) Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 � e aceAnalytical xwwpacefabs.corn i February 18, 2016 One Time Client Private Small Jobs Huntersville, NC 28078 RE: Project: Pond Discharge Pace Project No.: 92285288 RECEIVED CENTRAL. FILES DWR SECTION Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 REGENED SUN a g 2bls DWRFILES g CTION Dear One Client: Enclosed are the analytical results for sample(s) received by the laboratory on February 04, 2016. The results relate only to the samples included in this report. Results reported herein conform to the most current TNI standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. Analyses were performed at the Pace Analytical Services location indicated on the sample analyte page for analysis unless otherwise footnoted. If you have any questions concerning this report, please feel free to contact me. Sincerely, i,;, C,�—�- Liamm Harrison liamm.harrison@pacelabs.com Project Manager Endosures REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page i of 11 ac,Mnalytical o wwwpao&AftWm Pace Analytical Services, Inc. 9800 Kinoey Ave. Suite 100 Huntersville, NC 28078 (704)8759092 CERTIFICATIONS Project: Pond Discharge Pace Project No.: 92285288 Charlotte Certification IDs 9800 Kinsey Ave. Ste 100, Huntersville, NC 28078 South Carolina Certification #: 99006001 North Carolina Drinking Water Certification #: 37706 Florida/NELAP Certification #: E87627 North Carolina Field Services Certification #: 5342 Kentucky UST Certification #: 84 North Carolina Wastewater Certification #: 12 VirginialVELAP Certification M 460221 Eden Certification IDs 205 East Meadow Road Suite A, Eden, NC 27288 North Carolina Drinking Water Certification #: 37738 North Carolina Wastewater Certification #: 633 VirginiaNELAP Certification #: 460025 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. Page 2 of 11 aceAnalyrrcal www.pacefabccam I SAMPLE ANALYTE COUNT Project: Pond Discharge Pace Project No.: 92286288 Pace Analytical Services, Inc. 9000 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92285288001 Pond Water SM 2540D DWJ 1 PASI-E SM 254OF CHM 1 PASI-E EPA 1664E JMS 1 PAS I-C REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc., Page 3 of 11 Pace Analytical Services, Inc. aceMaIX cal' 9a0� KinceyAve. Suite Huntersville, NC 2807878 www-- bs,com (7o4)875-9092 ANALYTICAL RESULTS Project: Pond Discharge Pace Project No.: 92285288 Sample: Pond Water Lab ID: 92285288001 Collected: 02/04/16 08:50 Received: 02/04/16 09:49 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 2540D Total Suspended Solids Analytical Method: SM 2540D Total Suspended Solids 20.2 mglL 2.5 1 02/09/16 08:54 2540E Total Settleable Solids Analytical Method: SM 254OF Total Settleable Solids ND mUUhr 0A0 1 02/05116 13:25 HEM, Oil and Grease Analytical Method: EPA 1664B Oil and Grease ND mg1L 5.0 1 02/17/16 08:00 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 02/18/2016 03:35 PM without the written consent of Pace Analytical Services, Inc.. Page 4 of 11 aceAnalytical. www.pacebb&com Project: Pond Discharge Pace Project No.: 92285288 QC Batch: EDEN121692 QC Batch Method: SM 2540D Associated Lab Samples: 92285288001 METHOD BLANK: 1662044 Associated Lab Samples: 92285288001 Parameter Units Total Suspended Solids mg1L LABORATORY CONTROL SAMPLE: 1662045 Parameter Units Total Suspended Solids mg1L SAMPLE DUPLICATE: 1662046 Parameter Units Total Suspended Solids mg1L Pace Analytical Services, Inc. 9800 Kinoey Ave. Suite 100 Huntersville, NC 28078 (704)8759092 QUALITY CONTROL DATA Analysis Method: SM 2540D Analysis Description: 2540D Total Suspended Solids Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.5 02/09/16 08:52 Spike LCS LCS % Rec Conc. Result %Rec Limits Qualifiers 250 256 102 90-110 92285393001 Dup Result Result RPD Qualifiers 53.6 50.4 6 D6 SAMPLE DUPLICATE: 1662208 92285387001 Dup Parameter Units Result Result Total Suspended Solids mg1L 18.2 24.3 RPD Qualifiers 29 D6 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in Full, Date: 0211812016 03:35 PM without the written consent of Pace Analytical Services, Inc.. Page 5 of 11 aceAnalytical wwwpawaucam QUALITY CONTROL DATA Project: Pond Discharge Pace Project No.: 92285288 QC Batch: EDEN/21682 Analysis Method: SM 254OF QC Batch Method: SM 254OF Analysis Description: 2540F Total Settable Solids Associated Lab Samples: 92285288001 METHOD BLANK: 1661000 Associated Lab Samples: 92285288001 Parameter Units Total Settleable Solids mL/L/hr Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.10 02/0511613:25 SAMPLE DUPLICATE: 1661001 92285288001 Dup Parameter Units Result Result Total Settleable Solids mUL/hr ND ND RPD Qualifiers Pace Analytical Services, Inc. 9800 Kinsey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Results presented on this page ale In the un@s Indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 02/18/2016 03:35 PM without the written consent of Pace Analytical Services, Inc.. Page 6 of 11 aceAnalytical e wwwpawabsoom QUALITY CONTROL DATA Project: Pond Discharge Pace Project No.: 92285288 QC Batch: GCSV124118 Analysis Method: EPA 1664B QC Batch Method: EPA 1664E Analysis Description: 1664 HEM, Oil and Grease Associated Lab Samples: 92285288001 METHOD BLANK: 1667427 Associated Lab Samples: 92285288001 Parameter Units Oil and Grease mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers NO 5.0 02/17/16 07:45 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 LABORATORY CONTROL SAMPLE: 1667428 Spike LCS LCS • % Rec Parameter Units Conc. Result e% Rec Limits Qualifiers Oil and Grease mg1L 40 35.4 88 78-114 MATRIX SPIKE SAMPLE: 1667429 92286053001 Spike MS MS °% Rec Parameter Units Result Conc. Result e% Rec Limits Qualifiers Oil and Grease mg1L ND 40 39.3 98 78-114 Results presented on this page are in the units Indicated by the "Units" column except where an alternate unit Is presented to the right of the resuh. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 0211812016 03:35 PM without the written consent of Pace Analytical Services, Inc.. Page 7 of 11 aceAnalytical www.pacaWbs.wm QUALIFIERS Project: Pond Discharge Pace Project No.: 92285288 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit. Pace Analytical Services, Inc. 9800KinoeyAve. Suite100 Huntersville, NC 28078 (704)8759092 S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether, Styrene, and Vinyl chloride. A separate via] preserved to a pH of 4-5 is recommended in SW846 Chapter for the analysis ofAcrolein and Acrylonitrile by EPA Method 8260, N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited ana]ytes. TN -The NE LAC Institute. LABORATORIES PAS I-C Pace Analytical Services - Chariotte PASI-E Pace Analytical Services - Eden ANALYTE QUALIFIERS D6 The relative percent difference (RPD) between the sample and sample duplicate exceeded laboratory control limits. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 02/18/2016 03:35 PM without the written consent of Pace Analytical Services, Inc.. Page 8 of 11 aceAnalyfical o rwwpateleDs.carn QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Pond Discharge Pace Project No.: 92285288 Pace Analytical Services, Inc. 980o VinoeyAve. Suite 100 Huntersville, NC 28078 (704)8759092 Lab ID Sample ID QC Batch Method QC Batch Analytical Method 92285288001 Pond Water SM 2540D EDEN121692 92285288001 Pond Water SM 254OF EDEN121682 92285288001 Pond Water EPA 1664E GCSV124118 Date: 02/18/2016 03:35 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, exoept in full, mthout the written consent of Pace Analytical Services, Inc.. Analytical Batch Page 9 of 11 r,! �aceAra*ical' r Document Name~ Sample Condition Upon Rece Document No.: F-RAL-CS-001-rev.03 Document Revised: 260CT2015 Page 1 of Z Issuing Authority: Pace Huntersville Quality Office ' Client Name: Project 9: W®# : 92285285 + I Y 1 111 mu1 .Courier: _ ❑Fed Ex ❑UPS ❑LISPS OCllent ❑Commercial []Pace ❑other: 92285288 I + Custody Seal on Cooler/Box Present? ❑Yes QNo Seals Intact? ❑Yes 4No Packing Material: ❑Bubble Wrap ❑Bubble Bags ONone []Other: Thermometer IR Gun SN: IZ2065387 Used: IR Gun SN: 122065371 Type of Ice; • ,OWlet ❑Blue []None ©samples on Ice, cooling process has begun Cooler Temp Corrected ('C): 15. 5 Biological Tissue Froten? []Yes ❑No dN/A - To mp, should be above freezing to 6'C Correction Factor: USDA Regulated $ofi ([ j N/A, water sample) 0.01C Date and initials of Person Examining Contents: Z t .ginate In a quarantine zone within the United States: Old sampies qNo ❑Yes CA, NY, or SC (check maps)? Did samples originate from a foreign source (internationall , VNo including Hawail and Puerto Rico)? ❑Yes If Yes to either question, fill out a Regulated Soil Checklist and Include with SCUR/COC paperwork. COMMENTS: Chain of Custody Present? OYes []NO ❑N/A 1, Chain of Custody Filled out? Yes EIND Q N/A 2. Chain of Custody Relinqulshed7 Yes 0110 EJNJA 3. Sam ler Name and/or Signature on COC? Yes ONO ❑NIA 4. Samples Arrived within Hold Time? Yes I o NIA 5. Short bold Time Anal sIs <72 hr)? Yes QNo N A 6.5) Rush Turn Around lime Requested? Dyes No ©N/A 7. Sufficient volume? 11yes Na NIA S. Correct Containers Used? Yes No ©N/A 9. -Pace Containers Used? 61es No N/A Contalners Intact? Yes LJN0 NIA 10. Filtered Volume Received for Dissolved Tests? QYes QN0 /A 11. Note ff sediment Is visible In the dissolved container Sample Labels Match CW Dyes [jNO ❑N/A 12, Includes Oate/Time/ID/Analysis Matrix: All containers needing acid/base preservation have been 13 checked? Yes ©No ❑NIA All containers needing preservation are found to be in compliance with EPA recommendation? (HND,, H2SO4, HCI<2; NaOH>9 Sulfide, NaOH>12Cyanide) 4 Yes ©NO ❑N/A Exceptions: VOA, Coliform, TOC, 011 and Grease, DRO/8015 (water) DOC,LLHg es ONo NIA Samples checked for dechlorization 9hes ONo []N/A 14. Headspacein VOAVIais(>5-6mm)? Yes , []No. /A 15. Trip Blank Present? OYes ©No N/A 16. Trip Blank Custody Seals Present? [:]Yes. []No ONIA Pace Trip Blank Lot # (if purchased): CLIENT NOTIFICATION/RESOLUTION Field Data Requlred? ❑Yes ONO Person Contacted: l Date/Tirne: Gomments(Resolutlon: � �rt[rftli� 51i�CilYl{ ii� 1'�41n,n1C__S13IU/1 YVIIA,inM •a, A u _ Project Manager SCURF Review; LL1 _ _ • . _ INate: V i__ a DE Note,. Whenever there is a discrepancy affecting Nrth Carolina compliance samples, a copy of this form will be sent to the North CarolinHNd Cent aGn Office (i.e. out of hold, incorrect preservative, out of temp, incorrect containers). aceAnaVical W".pacalabs.com ! 6701 Conference Drive, Raleigh, NC 27607 Ph: (919) 834-4984, tax. 1919) 634-64e7 NCWW Cat#97, NCDW Cer1#37731 Chain of Custody Report ReN!as Bill To: Companyr r & w<. Address: Attn: -tw-A� "F Phone: Fax: Sampled by (signature): Project Reference: CI A / Project Number: Purcha?ndard rder /> ; Report Delivery ❑ Rush Report Delivery (wlsurcharge) "Rush pmiactu aro sublad to prior approval by the laboratory Requested Due Date: Relinquish (sg R v by (signature ^ 04=&. Date ��10 V Time q-Al Relinquished by (signature) i Red by (ature) Date Time Relinquished by (signature) Received by (signature) Date lithe Receipt t arwmor%s (t_au use Vny) G7 4t2°C GYfemp: °C Res. Chiorine: 0 Absent ❑ Present 0 n!a Acid presety. <27 ❑Yes El No ❑We base preserv. 127 ❑ Yes ❑ No ❑ We Page 11 of 11 i^- PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14' D 3 FACILITY NAME: _01_1P 4aits W o, t E-_ LI17 PERSON COLLECTING SAMPLES: lI1nCEvt{ `1�A5�n, r �ay� CERTIFIED LABORATORY:Lab # i Z Lab # LIMIT VIOLATIONS? YES []NO Part A: Wastewater Monitoring Requirements SAMPLE COLLECTION YEAR: Zo 1 to SAMPLE QUARTER: []Jul -Sept ❑Oct -Dec Jan -March ❑April -June COUNTY: WA_ - PHONE NO. (III—) ' t 1- — e Z2'Z ADD TO LISTSERVE? F4YES ❑NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA []Trout �00ther{4_&2_'�_0 OPTIONAL INFO: Outfall No. Date Sample 1 Collected (mm/dd/yr) Type of Wastewater (VE, RM, MD)' pH (standard) Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH using method 1664A SGT-HEM' (mg/L) Discharge Duration (minutes) Total Flow r (gallons/day} - - - 6-93.4 303,5 53 (15)6 - - -n CENTRAL Eli ES R SE CT! 1 If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. 2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 I 6 Rrocess wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY INCLUDING ALL "NO FLOW" "NO DISCHARGE" WITHIN 30 DAYS OF RECEIPT OF SAMPLE OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919)807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware hat there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signaturd,of Permittee) Permit Date: 7/1/2010-06/30/2015 / /6 D e) Last Revised 07/13/11 Page 2of2 4 F CONTACTS EXISTING PROPERTY OWNER: JENCO CONCRETE ASSOCIATES, INC. 45 SOUTH 4TH ST. SUITE 1 BAY SHORE, NEW YORK 11706 ATTN: JIM LOCHREN DEVELOPER: JENCO CONCRETE ASSOCIATES, INC. 45 SOUTH 4TH STREET BAY SHORE, NEW YORK 11706 ATTN: JIM LOCHREN CIWIL ENGINEER: KIMLEY—HORN AND ASSOCIATES, INC. POST OFFICE BOX 33068 RALEIGH, NORTH CAROLINA 27636 PHONE: (919) 677-2000 FAX: (919) 677-2050 ATTN.: JEFFREY J. WING, P.E. LANDSCAPE ARCHITECT: KIMLEY—HORN AND ASSOCIATES, INC. POST OFFICE BOX 33068 RALEIGH, NORTH CAROLINA 27636 PHONE: (919) 677-2000 FAX: (919) 677-2050 ATTN.: JEREMY S. ANDERSON, RLA SURVEYOR: THE CHANDLER GROUP 7621 PURFOY ROAD, SUITE 201 FUQUAY—VARINA, NC 27526 PHONE: (919) 552-4845 FAX: (919) 552-6962 ATTN: JOHN CHANDLER CONSTRUCTION PLAN SUBMITTAL FOR JENCO CONCRETE PLANT 512 THREE SISTERS ROAD WAKE COUNTY, NORTH CAROLINA DEVELOPED BYE JENCO CONCRETE ASSOCIATES, INC. 45 SOUTH 4TH STREET BAY SHORE, NEW YORK 11706 PREVIOUSLY APPROVED UNDER PERMIT •0081555 rlc.nl4ow VIRGINIA NORTH CAROLINA EDEN OXFORD 501 LO���icBt�R 85 GREENSBORO • 40 70 1 DURHAM WAKE FOREST ZEBULON 540 • CHAPEL 40 KNIGHTDALE 64 HILL 440 ASHEBORO 15 CARY• • 64 RALEIGH CLAYTON 1 GARNER • LP�CT • 40 FUQUAY-VARINA SANFORD 95 FAYETfEVILLE • VICINITY MAP ALTa PREPARED IN THE OFFICE OF: KNIGHTpgLE BLVp VS O N �p W CD 10 � 2 o PROJECT 3 v 0 z = KI'm1eymHorn and Associates P.O. BOX 33068 - RALEIGH, NORTH CAROLJNA 27636-3068 PHONES (819) 677-2000 FAX (919) 677-2050 LOCH TION MAP JV T.S Inc. SEp yyeitzsrx3s L Sjo, ,water Wj B ► f � i �Ep g 2U08 DEi�K . Gi�TE� Fi Q�UAL wwN:l'slda f, st" r" 1wei6t Br8 SHEET INDEX 8F� DE�CFiPTION NO. C-0 TITLE SHEET C-1 DEMOLITION & INITIAL EROSION CONTROL PLAN C-2 SITE PLAN C-3 GRADING, DRAINAGE AND UTILITY PLAN C-4 EROSION CONTROL PLAN C-5 CONSTRUCTION DETAILS C-6 STORMWATER MANAGEMENT DETAILS C-7 EROSION CONTROL DETAILS C-8 WATER & SEWER DETAILS LA-1 I LANDSCAPE PLAN 4 05/05/08 REVISED PER WAKE COUNTY & NC DWQ REVIEW COMMENTS RTL 03/25/08 REVISED FEEDER BIN LAYOUT & ADDED OPERATIONS TRAILER JCA 03/12/08 CONSTRUCTION PLANS JCA 10 09/28/07 WAKE COUNTY REVIEW COMMENTS CMD NO. DATE DESCRIPTION BY This document, together with the concepts and designs presented herein, as an instrument of services, Is intended Gam^ only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document 2,0 without written authorization and adaptation by Kimley—Hom and Associates, Inc. shall be without liability to Kimley—Horn and Associates, Inc. Copyright Kimley—Horn and Associates, Inc., 2008 SEL: DATE: KHA PROJECT NO: AUGUST 3, 2007 1 012858000 804 I At3 Mo-p 30 SW t'T -. r � t•. � �Tt .I� I(� •`! lyy ��. A: t•�•�.. .-I .... .. � - .I-... ,. .... ... �. 't.C: ,.. �'. I.i tit - t:, ._.i... _.�.�.. / TREE �\\\ , ,\\ c/ NIF C C/ ROPOSED BYPASS PIPE/ FENTYP/ TO BE INSTALLED PRIOR ARGARET DEAN I1} Llb TO CREEK DISTURBANCE. 25iING 0� WMITS OF PEO//SEE GRADING, DRAINAGE' Go SETBACK --GIBSON MARTIN z DISTURPANCE/ Try & UTILITY PLAN FOR DB 2577 252 DESIGN DETAILS PK N��� PIN: 1764865965 -Q b'1� I \ \ \\ In \�I IIIIjIIl11 �Ih � �- \ 1 + �I I II III11' \n Nli io 1 1 eXI51'I/NX/ / F/TA+1Q,N INSIJ/ •/ i/ /l/. // /I1 I I i 1 I \ \ J\ \( ` \ \ \ \ \ \ II \ iN NC EXISTING ROCK OURO,' TREEP� /TO /WOW;/.7 TO BE REMOVED TO LIMITS � 141 r�2 OF DISTURBANCE EXISTING HECK DAM UTO BE REMOVED / WENDELL FALLS DEVELOPMENT, LLC. II111IJECl EXISTING CREEK I I( i!! y I I I / /1 I / / / > 2'47,F, ,P'G 1829/ / / (SEE MAPPING DB 11755, PG 2624 D / SOURCES NOTES l/ • I I I/ / J J I/ I I � 1, \ \ \ R I PIN:1764849503 I�IIIIII I l iI iII I ` \ / P k�/T 1, l I,1 ( 1 /\ 1\ I ( Ir43 & #4) EXISTING TREES TO zlurq/ (i � / RR rn I ( ! I I ( BE REMOVED WITHIN STANDARD TEMPORARY DIVER'SIAN � ' I I I I I I I \ PROTECTION AREA / -DITCH 0 BE INSTALLED / III II) III\/ I RE DURING INITIAL CLEARING / DRIVEWAAND BYPASS PIPE //{•/ / / / / / l) / / ( , I I` \ \ \ \ \ \ \\ \ /TEMPORARY /INSTALLTION, TYP. CONSTRUCTION ENTRANCEINSTALL TEMPORARY l STREAM CROSSING WITH 2-36" CMP'S / / / 1r 1 \ \ cr \ \ \ \ \/ \31 I I �(I►I I I �, / / / / \ SL PE , IN IDE I \ \ N/�� TEMPORARY CUSTOM \ \ \ \ \ >Cj�'!i fii i // O. r I I I EXISTING CHECK DAM OP� \SEDIMENT BASIN2 \ >s v J 1 III I TO BE REMOVED / / / / / OPTS WITH BAFFLES PER \ \ \� i� i �// j FOP RR R / % DETAILS i -i/�/ /� / O I I ! I I I I EXISTING TREES TO / / I ` �� \ \ \ \ \ \ CP\ I I ( I I BE REMOVED WITHIN I , \ No \ \✓ , i %�. i/ j% PROTECTION AREA FOR I I I it I f I I I F ELDFUTURE SEPTIC NON —FLOOD HAZARD QD II ! I I SILT FENCE TO BE INSTALLED \ \ •GJ \ /� �/ / PRONE SOILS, TYP. ALONG BOTH SIDES OF CREEK'��j� / DURING INITIAL CLEARING AND v ( ( f I I ! I I BYPASS PIPE INSTALLATION I! TEMPORARY STANDARD N I (II ( I I ! I ! I I / CUSTOM SEDIMENT I 5 SPILLWAY I :1 csi (I I !III I I I ! / PER I DE NTH BAFFLES I \ 1 ` ELEV=254.50 \ �LOf E I / / � � �j NC DOT , i// / TRAVERSE STATION 3.SID LOP I ! ( I I I \ N BY104-2 i / c, / / L / �� 1 III (I II I1�II 'a 2: o 24 RCP / 1 I I i\ I o DE I I INV=257.95 1 I III 1 �� I I / I / 260 — J I % / A- X CONTRACTOR IS RESPONSIBLE — — J \ / / /// / 0 x45 x24 THICK FOR PROTECTING EXPOSED — — — RIP RAP APRON. �1I ( j� I �/j CLASS 1 STONE / PIPE DURING CONSTRUCTION .I-! ! 1 I ! I\\ ( 11 `ETA ON \ I ! I i / ' // jj j / /// j ON FILTER FABRIC / BEFORE FINAL FILL IS PLACED. V j/ I� 1�! I I I 1 j' I! / / PROTECTION AREA10 011 I , I (I I \� — COMBINATiQ�V SILK " — 3 / \//,//�/j / / /`/ EXISTING TREES TO FENCE/TREE \ <� /// / /�v / BE REMOVED WITHIN EXISTING PROTECTION \ \ — I / //��// / // PROTECTION AREA NI ! ( j II„ �\ DMANAGE —FEAR TYP. �` — �'/ // �// /� / �� FOR FUTURE 24 RCP6.9 I 1 I "Co �� 11111 \ \� SWALE \ �"" // / / INV-25 \ I O / / / �� STORMWATER MEASURES 11 ! I d' I I II I I / �- Eaclsi�Nc ' — -- _ \ \ \ \ �/ //� / d iCHECK DAM, \\� / / / / TEMPORARY SILT CHECK DAM \ I (! I II� I 25 TREE & SEE DETAIL THIS SHEET 0 I /) TYP. VEGETATION PROTECT — \ EXISTING EDGE A�RE/AA �-- — // //// /// 1I I ! 1111 \ IfF PAVEMENT // 111116 / / 4 1 I I \ \ ,�� FOP255 / EXISTING R/W / / / / / // � /� 50'4 OD BUFFER �/ /// /////// 30 "MP (�� / /�i/i �� / /� INV= 246.74 \ �I i it III I i ! y /�/� / / ;/;/ y\\ / /�// o / V / LLj lo ,/'� / N/F I III ! ! \ \ y� / CAROLYN PROPERTIES, L.L.C. DB 11721, PG 1278 /�- PIN: 1764750977 V (X / I I � I I I I II \ (/ / / / I i I I I ((II \ 6'CLF \ \ / f/��� ��� / NC DOT ,hC) TRAVERSE STATION I I . \ BY104-3 / II//j 4 REVISED PER WAKE COUNTY & NC DWQ REVIEW COMMENTS 05/05/08 RTL JJW ® CONSTRUCTION PLANS 03/12/08 JCA CMD 1 WAKE COUNTY REVIEW COMMENTS 09/28/07 JPK CMD REV. No.: REVISION: DATE: DRAWN BY: CHECKED BY: This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley—Horn and Associates, Inc. shall be without liability to Kimley—Horn and Associates, Inc. Copyright Kimley—Hom and Associates, Inc., 2008 PREPARED IN THE OFFICE OF: Kimley=Horn � F I and Associates, Inc. P.O. BOX 33068 — RALEIGH, NORTH CAROLINA 27636-3068 PHONES (919) 677-2000 FAX (919) 677-2050 12" MIN. 18" MAX. 11 SECTION A -A 2" MIN. TOP OF SILT CHECK DAM SHALL BE 1' MIN. BELOW LEVEL OF LOWEST BANK. STREAM INVERT 12" MIN. 18" MAX. "'ILLWAY SHALL BE MIN. BELOW TOP SILT CHECK DAM REAM INVERT STONE FACING —#57 STONE �,..,�.. %il" " ,,-12RIP—RAP SECTION B-B TEMPORARY SILT CHECK DAM N TS CLIENT: ' .% JENCO CONCRETE ASSOCIATES, INC. TITLE DEMOLITION 8 INITIAL EROSION CONTROL PLAN SEAL: I. DATE: 08/3/07 HORIZONTAL SCA �¢CSi 1 "_ 4n' IED BY: JCA ED BY: CMD GENERAL NOTES 1. ALL PRIMARY UTILITIES DISCOVERED DURING CONSTRUCTION THAT SERVE EXISTING FACILITIES OTHER THAN THE SITE IMPROVEMENTS SHALL BE PROPERLY PRESERVED AND PROTECTED. 2. THE CONTRACTOR SHALL IMMEDIATELY REPORT TO THE OWNER AND ENGINEER ANY UNFORESEEN OR ADVERSE CONDITIONS, INCLUDING UNCHARTED UTILITIES, DISCOVERED DURING CONSTRUCTION. 3. THE CONTRACTOR SHALL CONFIRM LOCATION, DEPTH, SIZE, AND INVERTS OF EXISTING STORM SEWER, WATER, AND SANITARY SEWER LINES PRIOR TO START OF WORK. 4. SEE EROSION CONTROL PLAN (SHEET C-4) FOR CONSTRUCTION SEQUENCE. MAPPING SOURCES 1. EXISTING CONDITIONS BASED ON BOUNDARY & TOPOGRAPHIC SURVEY OF LOT 11 THOMPSON INDUSTRIAL PARK, 12/27/2006, COMPLETED BY THE CHANDLER GROUP. THE EXISTING PROPERTY LINE IS DEEDED TO CENTERLINE OF THREE SISTERS ROAD. 2. LIMITS OF NON —FLOOD HAZARD PRONE SOILS BASED ON THE SOILS EVALUATION PREPARED BY S&EC ON SEPTEMBER 9, 2003. 3. NORTH CAROLINA DIVISION OF WATER QUALITY ISSUED AN ONSITE DETERMINATION ON MAY 13TH, 2002, STATING THAT THE EXISTING ONSITE CREEK IS NOT SUBJECT TO NEUSE BUFFER RULES. 4. UNITED STATES ARMY CORP OF ENGINEERS CONDUCTED A SITE VISIT ON JANUARY 23, 2007 AND DETERMINED THAT THE EXISTING ONSITE CREEK IS AN INTERMITTENT UNIMPORTANT STREAM CHANNEL. SURVEY LEGEND RR R/W — — RCP========== R/W — — -----375— — — — /// TPF TPF IPF rPS 0CP CMF MP PKS 0FOP 0 GRAPHIC _SC 40 0 20 40 8 PROJECT: ( IN FEET ) 1 inch = 40 ft. PROPERTY LINE EASEMENT LINE EP EDGE OF PAVEMENT RAILROAD RIGHT OF WAY REINFORCED CONCRETE PIPE RIGHT OF WAY OVERHEAD POWER LINE MINOR CONTOUR MAJOR CONTOUR SILT FENCE/TREE PROTECTION FENCE TREE PROTECTION FENCE LIMITS OF DISTURBANCE GUY WIRE UTILITY POLE IRON PIPE FOUND IRON PIPE SET CALCULATED POINT CONCRETE MONUMENT FOUND METAL PIPE PK NAIL SET FIBER OPTIC POST GRAVEL RIP RAP NON —FLOOD HAZARD PRONE SOILS Tl TR E TEMPORARY SILT CHECK SLOPE DRAIN 160 JENCO CONCRETE PLANT 512 THREE SISTERS ROAD WAKE COUNTY, NORTH CAROLINA ATTACHED REFERENCE FILES: JOB NUMBER: SHEET NUMBER: 1012858000 1 C-1 Box:# 1,�3 31 51,v/ r{ -71- , t' 50' TREE & VEGETATION PROTECTION AREA N/F WENDELL FALLS DEVELOPMENT, LLC. DB 11755, PG 2624 PiN:1764849503 �TT I' I PROPOSED FULL -- MOVEMENT DRIVEWAY � J � I r� v 1 PROPOSED GROUND SIGN (DESIGNED BY 'C-.rN) CONTRACTOR) O Z7 O 00 . C7 (v ) ( rV I1 V I 680' SIGHT DISTANCE LINE, TYP. SITE LEGEND -e- SIGN �-- PAINTED TRAFFIC ARROW HANDICAP PARKING SPACE ® PROPOSED PAVEMENT STRIPING PROPOSED CURB AND GUTTER 20 PROPOSED PARKING SPACES PROPOSED CONCRETE PAVEMENT - - - PROPOSED EASEMENT PROPERTY LINE BUILDING SETBACK LINE/TREE & VEGETATION PROTECTION AREA BUFFER YARD �O PROPOSED SITE LIGHTING ►r I I I \� w PROPOSED DRAINAGE EASEMENT. I PROJECTED BACKWATER ELEVATION FOR N ( N/F c� / `-� THE 100-YR STORM = 262.24, I z Y \\ i0 Vi MARGARET DEAN 9 , , ?5�B to GIBBON MARTIN I m W r o DB 2577, 252 • I _ N N _ _ / _ _ _N83'21'53"W _ _ _ __ _ Z PIN: 1764865965 I ;n HC PARKING FUEL STORAGEOVE GROUND- BOLLARD, TYP. (DESIGNED 710.0' BUFFER YARD IPS SIGN 50' S.H.O.D. I 00 TANK (DESIGNED ' BY CONTRACTOR) I I WHEEL STOP, BY CONTRACTOR ''- 25' TREE & VEGETATION TYP a° PROPOSED 11'x44' 130 w PROTECTION AREA ° FUTURE OFFICE AND TEMPORARY RAM DP OWN FROM o I 345' MAINTENANCE BUILDING 20 X40 PLANT to OPERATIONS TRAILER STOCKPILE AREA 18. CURB AND (DESIGNED BY OTHERS) SUPPORT FACILITY RETAINING WALLS I N I I �1 ..( ;) i+- SEE NOTES ON THIS SHEET. -` LOADING AREA (DESIGNED BY OTHERS) S EYNOTES (DESIGNED BY 30' GUTTER (TYP.) I M �- WITH OVERHEAD CONTRACTOR) ROSS LINDEN ' * � A;d ' •' ON THIS SHEET. US-64 I STOP SIGN 18 �, GARAGE DOOR 'd: ENGINEERS) I • . OUNDATION , •• a RESERVE AREA O I I OvR ° PLANiiNG BEDS l.;, MATERIAL NOSE DOWN STto OCK PILE AND z l 25 BUILDING T • 34 (SEE LA-1) ..j END OF CURB o 0 0 0 0 FUTURE FEEDER I I 30 R, , , • ; �C : BINS &CONVEYOR LOADING AREA) i SETBACK RR R I iTYP. 5 .': �.:•.:.:;: ,,. 4. •`:�� R� BELT (DESIGNED BY ' I AMp 94 �6 •° a d 'As. Fffp Opp CON-E-CO) A d, d d °; ��. ` £R eiNS FROM / d d G '- `k / I° d 18"CURB AND ' / �' / IPF GUTTER (TYP.) ° I ° ` a ` d • .d . . . ' • CONCRETE PLANT 4 A. a d• ' (DESIGNED BY DELIVERY TRUCK CON-E-CO I ) ° 4 12a ° d : ° + SCALES FEEDER BIN & 4 ( ) ° d' d ' •'q ` OTHERS) (DESIGNED BY CONVEYOR BELT / 0 I ZAVEL (DESIGNED BY °- d CON E-CO) I J TYP i I I d d '�`�• �10 5' TRANSITION �` I TO FLUSH CURB TRUCK WAS � 0 4- �25' BUILDING I I I I d dd DOWN AREA '9• �S�OG , SETBACK R d I I o TRUCK FORTRANS 5000S 18" CURB AND I PARKING PH MONITORING GUTTER (TYP.) CP CONTRACTOR TO VERIFY I SYSTEM / FINAL LAYOUT OF FEEDER I I CONCRETE AREA SHALL BINS & PLANT EQUIPMENT / REMAIN AS GRAVEL UNTiL ,+l` / WITH MANUFACTURER i I I CONCRETE PLANT IS _- N6 / PRIOR TO CONSTRUCTING i OPERATIONAL. CONCRETE Ste, 6 RETAINING WALLS. WILL BE POURED ONSI CONCRETE CONCRETE �� '�ENGINEER SHALL BE / I ONCE A¶L ANT IS IN FLUME FLUME/ ��0�j / NOTIFIED OF ALL CHANGES OPERATION, I I 1 ER '� FROM THIS PLAN I I II I I� I i 50' TYPE 'A' I BUFFER YAR I ( I i I I I I I I I I I / I / AGGREGATE PIT & / I SETTLEMENT IS11NG CHAMBER (DESIGNED 3HT-OF-WAY BY ROBS LINDEN � ENGINEERS) / /AREASTORMWATER NC DOT OF PROPOSED MANAGEMENT POND VEGETATION TREE ND TRAVERSE STATION / / SEPTIC SYSTEM CP PROTECTION (DESIGNED AREA / BY104-2/ I BY S&EC) TEMPORARY OPERATIONS TRAILER NOTES: I/ / 1. 10'x40' TEMPORARY OPERATIONS TRAILER SHALL BE PROVIDED AS SHOWN UNTIL PERMANENT OPERATIONS & MAINTENANCE BUILDING IS CONSTRUCTED. 2. TEMPORARY TRAILER SHALL REMAIN ONSITE FOR A MAXIMUM OF 3 MONTHS. / AFTER 3 MONTHS, THE TRAILER SHALL BE REMOVED FROM THE SITE AND THE I/ �•9,QO PERMANENT OPERATIONS AND MAINTENANCE BUILDING SHALL BE USED. / 3. ADDITIONAL LANDSCAPING FOR THE TRAILER WILL NOT BE PROVIDED SINCE IT WILL BE D BUFFFER NSITE EAST, SOUTHRANDERWESTIOD O F THE SITE. F TIME AND WILL BE SCREENED BY WOODED 4. THE CONCRETE PARKING AREA FOR THE PERMANENT OPERATIONS BUILDING SHALL REMAIN AS GRAVEL UNTIL THE PLANT IS OPERATIONAL. THE OWNER WILL POUR THE CONCRETE PARKING AREA ONCE THE PLANT IS OPERATIONAL. , / 5. REFER TO THE COMCHECK SOFTWARE VERSION 3.4.2 ENVELOPE COMPLIANCE CERTIFICATE, APPROVAL DATE 12/4/07, AND THE ATTACHED DBI-1244W STOCK MODULAR BUILDING DRAWINGS DESIGNED BY PHILIP WITHERINGTON, P.E. OF 7903 SHORE BLUFF CT. TAMPA, FL 33637 (813) 988-9134 FOR ALL INFORMATION REGARDING THE TRAILER INSTALLATION. I / CP I / V / I � � .huh "00 N/F CAROLYN PROPERTIES, L.L.C. DB 11721, PG 1278 PIN: 1764750977 Q NC DOT TRAVERSE STATION SOP BY104-3 O / REVISED PER CONTRACTOR ARCHITECT COMMENTS 06/10/08 RTL JJW REVISED PER WAKE COUNTY AND NC DWQ REVIEW COMMENTS, REMOVED OFF -SITE GRADING 05/05/08 RTL JJW REVISED FEEDER BIN LAYOUT & ADDED OPERATIONS TRAILER 03/25/08 JCA JJW A CONSTRUCTION PLANS 03/12/08 JCA CMD Al WAKE COUNTY REVIEW COMMENTS 09/28/07 JPK CMD REV. No.: REVISION: DATE: DRAWN BY: CHECKED BY: This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and Improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc. Copyright Kimley-Horn and Associates, Inc., 2008 Box-$ J;�,3 A103 S �J PREPARED IN THE OFFICE OF: � Kimley=Horn � and Associates, Inc. P.O. BOX 33068 - RALEIGFi, NORTH CAROLINA 27636-3068 PHONES (919) 677-2000 FAX (919) 677-2050 TRUCK TRAFFIC FLOW DETAIL SCALE 1:40 CLIENT: JENCO CONCRETE ASSOCIATES, INC. TI TLE: SITE PLAN GENERAL SITE NOTES 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE LATEST WAKE COUNTY STANDARDS AND SPECIFICATIONS. 2. THE CONTRACTOR SHALL VERIFY DIMENSIONS AT JOB SITE. 3. ALL SITE LAYOUT DIMENSIONS TO FACE OF CURB AND FACE OF BUILDING, UNLESS NOTED OTHERWISE. 4. FINAL ZONING AND SITE IMPROVEMENT INSPECTION SHALL BE REQUIRED TO VERIFY SITE PLAN COMPLIANCE BEFORE A CERTIFICATE OF COMPLIANCE IS ISSUED BY WAKE COUNTY BUILDING INSPECTIONS. 5. DETERIORATED OR DEAD SCREENING SHALL BE REPAIRED OR REPLACED WITHIN SIX MONTHS. 6. NO PERMANENT CONSTRUCTION CAN OCCUR WITHIN BUFFER YARDS, UNLESS SPECIFIED ON THE PLAN. 7. SEPTIC TANK, SEPTIC DRAIN LINES ARE PROHIBITED IN REQUIRED BUFFER YARDS. STORMWAIER RETENTION AND DETENTION FACILITIES, STORAGE TANKS FOR ANY PURPOSE, UTILITY SUBSTATIONS, AND BUILDING HOUSING COMMODITIES OR EQUIPMENT ARE ALSO PROHIBITED IN REQUIRED BUFFER YARDS. 8. PROJECTED TRAFFIC COUNT BASED ON BUILDING CAPACITY AND PROJECTED ANNUAL PRODUCTION VOLUME OF 90,000 CUBIC YARDS. 9. THE PROPOSED OFFICE SPACE WILL BE USED BY 3 ADMINISTRATIVE AND 5 MAINTENANCE PERSONNEL. CONCRETE MATERIALS WILL BE STORED ONSITE. MECHANICAL REPAIR EQUIPMENT & MATERIALS WILL BE STORED INSIDE THE MAINTENANCE BUILDING. 10. NCDOT DRIVEWAY PERMIT IS REQUIRED FOR PROPOSED FULL MOVEMENT DRIVEWAY ON THREE SISTERS ROAD. 11. SITE LIGHTING SHALL COMPLY WITH WAKE COUNTY UNIFIED DEVELOPMENT ORDINANCE AND WILL NOT BE DIRECTLY VISIBLE FROM A VEHICLE TRAVELING ON US-64. 12. MAX ELEVATION OF BUILDING SHALL BE HEIGHT 430.10' BASED ON THE ELEVATION OF US-64 ADJACENT TO THE SITE. ELEVATION OF US-64 IS APPROXIMATELY 306.10' PER DESIGN INFORMATION PROVIDED BY NCDOT. PER WAKE COUNTY UDO SECTION 3-71-3-(B) MAXIMUM BUILDING HEIGHT SHALL EQUAL THE ELEVATION OF THE SPECIAL HIGHWAY (306.10') PLUS 60', AND AN ADDITIONAL 1' OF HEIGHT FOR EVERY 2' OF DISTANCE FROM THE SHOD BUFFER YARD TO THE BUILDING OR STRUCTURE. THE SHORTEST DISTANCE FROM THE TALLEST STRUCTURE TO THE SHOD BUFFER YARD IS APPROXIMATELY 128'. HEREFORE, THE MAXIMUM ALLOWABLE ELEVATION OF A STRUCTURE SHALL BE 306.10'+60'+128'/2 = 430.10'. THE TALLEST PROPOSED STRUCTURE IS THE CONCRETE PLANT SILO WHICH HAS A HEIGHT OF 75' AT PROPOSED FINISHED GRADE ELEVATION OF 276.00' AND A TOP ELEVATION OF 351.00'. 13. SOLID WASTE WILL BE HANDLED BY A PRIVATE COLLECTION SERVICE WITH CONTAINERS LOCATED INSIDE THE MAINTENANCE BUILDING. 14. FORTRANS 5000S PH MONITORING SYSTEM DESIGNED BY OTHERS. CONTACT BOB COOKE AT (919) 365-8004 FOR PRODUCT DATA AND INSTALLATION INSTRUCTIONS. 15. SEE STRUCTURAL PLANS BY ROSS LINDEN ENGINEERS FOR AGGREGATE PIT, SETTLEMENT CHAMBER, RETAINING WALL AND PLANT EQUIPMENT FOUNDATION DESIGN. 16. SEE PLANS BY CON-E-CO FOR ALL CONCRETE PLANT EQUIPMENT DESIGN, DIMENSIONS, ELEVATIONS, ETC. PROJECT DATA SITE DATA TABLE TOTAL SITE AREA 5.97 AC STREET ADDRESS 512 THREE SISTERS ROAD KNIGHTDALE, NC 27545 PARCEL IDENTIFICATION NUMBER PIN 1764-75-7306 DESCRIPTION LOT 11 THOMPSON INDUSTRIAL PARK DISTURBED AREA 3.75 AC (163,432 SF PROPOSED BUILDING OFFICE & MAINTENANCE BUILDING PARKING REQUIRED 8 OFFICE & MAINTENANCE BUILDING REGULAR SPACES BASED ON 1 SPACE/2 EMPLOYEES PLUS 10 TRUCK SPACES, 1 PER CONCRETE TRUCK. INCLUDING HANDICAP ACCESSIBLE PARKING SPACE. HOURS OF OPERATION I M-F 7: OOAM-6: OOPM SAT 7: AM-12: OOPM PARKING PROVIDED 14 SPACES INCL. 1 HC AND 10 TRUCK SPACES MAXIMUM # OF EMPLOYEES 15 ZONING INFORMATION EXISTING ZONING 1-2 EXISTING USE VACANT, UNDEVELOPED MIN. LOT SIZE 10,000 SF OR 0.23 AC. PROPOSED INTENSITY MEDIUM INTENSITY - NON-RESIDENTIAL OVERLAY DISTRICT: SPECIAL HIGHWAY OVERLAY DISTRICT (SHOD) BUFFER YARD: 50' SOUTH AND EAST BOUNDARY S.H.O.D. TREE PROTECTION AREA: 25' SOUTH AND EAST BOUNDARY 50' WEST BOUNDARY REQUIRED BUILDING SETBACKS FRONT: 50' SIDE: 25' REAR: 25' MAXIMUM BUILDING HEIGHT 75' (TOP CONCRETE PLANT SILO ELEVATION 351.00') MAX ALLOWABLE BUILDING HEIGHT PER SHOD MAXIMUM ELEVATION OF BUILDING IS 430.10' BASED ON THE ELEVATION OF US 64 BYPASS. SEE SITE NOTE #12. FLOOR AREA RATIO (FAR) CALCULATIONS: TOTAL FLOOR AREA: 0.11 AC. 4,800 SF TOTAL SITE AREA: 5.97 AC. 259,923 SF FAR: 0.018 4800 SF/259,923 SF) IMPERVIOUS COVERAGE: TOTAL IMPERVIOUS AREA: 2.20 AC, 95,858 SF IMPERVIOUS:: 36.88% ONSITE EASEMENTS: NONE - PROPOSED DRAINAGE EASEMENT FROM ADJACENT PROPERTY ROADWAY INFORMATION TRAFFIC IMPACT ANALYSIS NOT REQUIRED DRIVEWAY ACCESS THREE SISTERS ROAD (MINOR THOROUGHFARE) OFF -SITE IMPROVEMENTS N/A TRAFFIC GENERATION DATA DAILY MAX EMPLOYEES: 32 DAILY MAX CONCRETE PRODUCTION: 39 TOTAL DAILY MAX: 71 UTILITY AVAILABILITY WATER NONE -PROPOSED WELL SANITARY SEWER NONE -PROPOSED SEPTIC TANK STORM SEWER SITE STORMWATER WILL DISCHARGE TO AN EXISTING 30" METAL PIPE UNDER RR AND DRAINAGE DITCH ALONG THREE SISTERS. NATURAL GAS N/A ELECTRIC OVERHEAD (PROGRESS ENERGY) TELEPHONE/CABLE OVERHEAD SITE DISTANCE SITE DISTANCE LINE: 680.00' SOURCE: NCDOT POLICY ON STREET AND DRIVEWAY ACCESS TO NC HIGHWAYS. CkRN-1 a. V �/I8ft GRAPHIC SCALE 40 0 20 40 80 DATE: 08/3/07 HORIZONTAL SCALE: 1 "= 40' VERTICAL SCALE: N A DRAWN BY: JCA DESIGNED BY: JCA CHECKED BY: CMD 160 PROJECT: i inch = 40 ft. JENCO CONCRETE PLANT 512 THREE SISTERS ROAD WAKE COUNTY, NORTH CAROLINA ATTACHED REFERENCE FILES: JOB NUMBER: 012858000 NUMBER: C-2 IIII `, I \ �/ I Wl 1 COORDINATE BYPASS \ \ t ! / �7 /PROPO D WELL I IP CO STIjUCTION / \ \ } / / PRQPOSE DR41NAGE' 4-OCA 0N / / / TW U STREAK1� / J 1\\� \"1 01 \ / / EASE ENT T 2 2.00. \ �\ , l �\ \ \ I N F DENED / PIeOP TY/ STORMVygTER' �, / \ �ROJE TED CATER \ \ / (I I I III I )l \ I COOR INATE I NE,NV 2c / BY &E ' / / OU�A / / ,/ / ' \ \ \ i I EL VATI® FO THE 100-'YR \ \ \ \ TRANS 0 M R WVI I SL PE,IrYP. �5 / / � \E� lV , \ \ MARGARET DEAN o I I `L / / HEADWALL / \ \. \ \ `. ORwi = 2� �a \ \ \ \ \ T • PROGIR NE Glf / I , / ^� / INV=255.00 ST 2. 4.'GIBBON MARTIN ) ( I I / /2" PV� tV / / /(DESIGNED BY ROS (/ f I \ �js \ \ \ \ \ \ \ / , 252 Z I PK ,II I I ) ( / WATtLIN.4 LINDEN ENGINEERS) �� \ `���� \� ( { \ \ \ \ PIN: �764865965 o III (� I I \ I ( / /, - \ \ SLOP�, TYP. IPS O IIII lSEE GRADING AND \ \ \ uGE 2 / u \ 1 \ DRAINAGE NOTE #12 p I i I I II I I �I N 268 i .O 9 /.0 2 2:L71C2 8.7 27$\\0 OF 2�0 2 !6 LE 26§.00X 69.0AA-10BUILDINGS D TAIL " / ) JS'I218.1 8/5,`'/ABELLOW I \ \ \ \ \ \ \ I \ \�I\ \ \ \ ao ��✓ 1Jj /( I))IiIIII (III �IIIIII IIi((I(�IIi(I IIII II1II II 1I II\\/ ( j II !II I�IS, ' IRI T / , � R� E \\ \ INIAG \\ALLL \S \\ \ \\ 7\5�.15N/F ROBS�C8I�4%PES NT B�281NE;GINEES)WENDELL FAL2 900 Ew�S wdE 267. \ \\\ S \LOP\E II P.` .3\ 264/V267.%9 N.269.0 C REVE DB 11755, PG 2624 267. w./ / tf ARE �oRoPPIN• 1764849503 67.10\ RATER IA SER/ 268STOCK PILE / yOUT, 3YP/ S%/CR \%fAREAS, \ 6.0 � WP ' I s88 V 2�8 0 2.0 LODE / \ a,74.k087 LF 18" RCP 01.15% 7• S(FIELD VERIFY INVERTS ���830L4„PVC FTO MAINTAIN A MIN. 2' f 47%MIN. 267•1 EOF COVER) I � 64.1 2( .7 O , . NV 6 .1 -r� .i RR \cj� (( I RI I (, / / / 231 /L-F PVIC / cy / % \ , I \ r'�\ \ 2T .65\. ® /0.77./ IN/ / / 1 LF,4 Pvc 7� / / / /. CL A!? N T -0 Toy. MIN. 26) �� i�� i/ L / / 267.20 / O �62. 8 I { I INV 252 T4 a 'f(E TOP 0 / % / / / -F�HP I 1 / \ �� \ \ \ \\ i �i �� / S PTI R POrSED /66/ 0 / / tV / I 245 \ \ \ `�-� %'� (( I I I I I I I 1 L p _ E C/SYST�M / / 26`6.0 / I ( I o� 60 �ZCP \ \ s SEPTIC SYSTEM I I I i I 11vv=2 0 00 ( )/ l / I o i / RR DISTRIBUTION BOX I I I I I 2R n \ DESIGNED BY / / // 67 2 I 6 \ \ / % i / // 1.1\% \ \ i /�i�/ DESIGNED BY ! I I 31 LF PV .6 2i�6.15 G� / / ' 1 HP I \ �' \ \ \ \ \ / i�� �� �// // DyVERSION 7 �... . 67.10 \ �� / / SWALE FOR S&EC) � � ( of \ � / / ��` TRU K W SH i l 2sHP o cr \ \ \ �- I V OFF SITE DRAINAGE i I I ((I I I \ \ / / I ( C 66.00 \ \ ALP 6. \ LP \ \ 266t05 CO CR TE ' s I ) I ( 55• / ( FL ME C7 III I i I I I I I / I �S, - / I ON 4.7 / I - so- 2s \oo \ uM I I I 1 I I i (III S) 4�118. / I > > /// �ORTRANS 5000S oo 1j7-PH MONITORING / 'I °o I I SYSTEM (DESIGNED i II I I I l I I III Il / 6j Yes j\ �60 \ ,\ I\ ;/�/ j/% / / BY OTHERS) i ,III ,III ► I , I ► � / � R ,� � � _ � � � I I o - 6 x6 PAD sHowN/ N I \ 04Q NC DOT / 1 1 I I I I I i l i II \ \ \ y ��P / / / %/'XTRAVERSE STATION / / �/ STORM DRAIN BY104-2 V I cn / / _ ` MANHOLE (SEE SHEET C-6) / " RIM=266.50 / NVR257.95' � I 1 Illli jI �_-� � I � / •"��� ��� \ 260 I � ) ;-�. // , / � � INV=252.16 (THRU) PROPOSED - - - A�t STORMWATER MAGEMENT`� / / ' '' % /� % / / SEPTIC SYSTEM POND WITH NORMAL WATER '/ j ! �'�// / / AGGREGATE PIT & SETTLEMENT ZI I I I j ( ice\ I I \ (DESIGNED BY _SURF%�CE ELEV-. 258.00\ / /�jj j' j // j /j 65 LF 60" RCP CHAMBER. SEE SHEET C-6 FOR _-:1 I/ ��I \s&Ec) ti �/ / ®1.11 % I / 4'x4' OUTLET C,ONTRL9L 0 / / �/ j j j f / /� / DETAILS AND DIMENSIONS (SEE LINDEN / STRUCTURE \ / /j / j /, // // STORM DRAIN ENGINEERS FOPLANS BY R STRUCTURAL I TOP=263.50 \ / / �f/// j/ ; j jam/ MANHOLE (SEE / DESIGN) INV=254.00 ` _ l \ jf/ / j f/ / /< /�O RIM ET C-6 / (SEE SHEET C-6 FOR \ - I ////// / 1, _ 5.50 / THINV=251RU)DETA - --64-LF 24" RCPC�36" R24,:RC5INV 26.9 NGXI FLARED EN / 006 STI ARAINAGE SECTION SWALE INV=253.50 I r.l i I I► l / \, ��\\�\ /�i/ i iiii�i\err HEADWALL INV=250.00. INVERT TO BE BURIED 1 t I III I I 111( \ 1 WASTEWATER BELOW FINAL GROUND I (1 III IIII \ \ I SAMPLING AND MATCH - - �/ / ///,/�/// /i / / \\ ELEVATION OF 251.00 I (I I \ ) DISCHARGE EXISTING �/ ,I / /� (SEE SHEET C-6) I I I I I ( \ \\ I I POINT GRADE )1 / PROJECTED BACKWATER ELEVA TION AT THE 255 INLET OF THE EXISTING 30" MP FOR THE 100-YEAR STORM IS 260.39 DXIS�NG\ 'MP RAINGE\ -30 ilIl DITCH 6.74\0 CP INV-24 \ \ l \ j% EXISTING GROUND //Ml / L Jill NIF CAROL YN PROPERTIES, L.L.C. DB 11721, PG 1278 (N PIN: 1764750977 6'CLF DOT / NC D / I /I 1 II►II \ /////� / /�i, j 2ss//%/ PO / TRAV�Y104-3ATION / PER NCDENR COMMENTS 08/14 08 RTL CMD PREPARED IN THE OFFICE OF: KimleywHorn and Associates,nc. REVISED PER CONTRACTOR ARCHITECT COMMENTS 06/10/08 RTL JJW REVISED PER WAKE COUNTY AND NC DWQ REVIEW COMMENTS 05/05/08 RTL JJW REVISED FEEDER BIN LAYOUT & ADDED OPERATIONS TRAILER 03/20/08 JCA JJW ® CONSTRUCTION PLANS 03/12/08 JCA CMD 1 WAKE COUNTY REVIEW COMMENTS 09/28/07 JPK CMD REV. No.: REVISION: DATE: DRAWN BY: CHECKED BY This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose P.O. BOX 33068 - RALEIGH, NORTH CAROLINA 27636-3068 and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc. PHONE. (919) 677-2000 FAX: (919) 677-2050 Copyright Kimley-Horn and Associates, Inc., 2008 CLIENT: GRASS LINED SWALE N PROPOSED PARKING SURFACE SWALE DETAIL "A" NTS JENCO CONCRETE ASSOCIATES, INC. TI TLE: GRADING, DRAINAGE AND UTILITY PLAN GRADING AND DRAINAGE NOTES: 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH WAKE COUNTY STANDARDS AND SPECIFICATIONS 2. SIDE SLOPES OF 3:1 USED TO THE EXTENT PRACTICABLE TO TRANSITION TO EXISTING GRADE. 3. CONTRACTOR IS RESPONSIBLE FOR ENSURING PROPOSED GRADES AND OTHER IMPROVEMENTS ARE CONSTRUCTED IN ACCORDANCE WITH ADA CRITERIA. CONTRACTOR MUST SHOW WHERE SLOPES CANNOT EXCEED 2% IN ANY DIRECTION AND ANY OTHER LIMITATIONS. 4. CONTRACTOR TO VERIFY DEPTH AND LOCATION OF EXISTING UTILITIES PRIOR TO START OF GRADING. 5. DIVERSION SWALES FOR OFFSITE DRAINAGE ARE INTENDED TO ROUTE OFFSITE DRAINAGE AROUND THE CONCRETE PLANT AREA WITHOUT COMMINGLING W/ONSITE PROCESS WATER. 6. ALL SPOT ELEVATIONS ARE SHOWN AS FLOW LINE UNLESS NOTED OTHERWISE. 7. FLOOD STUDY COMPLETED BY KIMLEY-HORN AND ASSOCIATES ON 8/3/07 DOCUMENTS APPROPRIATE SIZE FOR BY-PASS PIPE AND BACKWATER ELEVATION FOR 100-YEAR STORM EVENT. 8. PROPOSED WET DETENTION POND, AGGREGATE PIT, SETTLEMENT CHAMBER AND WATER QUALITY MONITORING SYSTEM SHALL TREAT PROCESS AREA STORMWATER RUNOFF IN ACCORDANCE WITH NPDES PERMIT #NCG140000. SEE STRUCTURAL PLANS BY ROSS LINDEN ENGINEERS FOR AGGREGATE PIT AND SETTLEMENT CHAMBER DESIGN. FORTRANS 5000S PH MONITORING SYSTEM DESIGNED BY OTHERS. CONTACT BOB COOKE AT (919) 365-8004 FOR PRODUCT DATA AND INSTALLATION INSTRUCTIONS. 9. TOTAL DISTURBED AREA: 3.75 AC 10. ALL RCP PIPE SHALL BE CLASS III UNLESS OTHERWISE NOTED. 11. PVC SANITARY SEWER PIPING SHALL BE SDR-35 UNLESS OTHERWISE NOTED. 2. REFERENCE GEOTECHNICAL REPORT DATED NOVEMBER 8, 2007 BY GEOTECHNOLOGIES, INC. FOR ADDITIONAL INFORMATION. SOIL SHALL BE COMPACTED TO 95% OF THE STANDARD PROCTOR MAXIMUM DRY DENSITY EXCEPT UNDER BUILDING PADS, PAVEMENT AND CONCRETE PLANT EQUIPMENT. THIS REQUIREMENT SHALL BE INCREASED TO 98% OF THE STANDARD PROCTOR MAXIMUM WITHIN 1 FOOT OF DESIGN GRADE OR FOUNDATION SLAB. FOR SLOPES STEEPER THAN 2.5:1 IT IS RECOMMENDED TO UTILIZE GEOGRID REINFORCEMENT IN THE OUTER 6 FEET OF THE SLOPE TO REDUCE THE POTENTIAL FOR SHALLOW SLOUGHING DURING THE WETTER WINTER MONTHS. TYPICALLY, TENSAR BX1100 GEOGRID IS PLACE VERTICALLY 2 FEET ON CENTERS AND EXTENDED 6 FEET BACK INTO THE FILLED SECTION FOR SLOPE ANGLES .j OF 2: 1. UTILITY NOTES: 1. A SEPTIC PERMIT APPLICATION WILL BE REQUIRED FROM WAKE COUNTY ENVIRONMENTAL SERVICES AS PART OF THE BUILDING PERMIT PROCESS. THE SEPTIC SYSTEM SHALL BE DESIGNED BY A NORTH CAROLINA LICENSED SOIL SCIENTIST BASED ON THE SOIL EVALUATION COMPLETED BY S&EC IN OCTOBER 2006. AN ORANGE SIGN WILL BE POSTED TO LOCATE THE PROPERTY AND THE CORNERS OF THE LOT AND THE PROPOSED SEPTIC TANK AND SYSTEM LOCATION WILL BE STAKED AND FLAGGED IN THE FIELD. 2. SETBACKS FOR THE SEPTIC SYSTEM SHALL BE 5-FEET FROM BUILDING FOUNDATION WITHOUT A DRAIN, 15-FEET FROM TOE OF A SIDE SLOPE, 25-FEET DOWNHILL FROM DRAINLINE, 100-FEET FROM WELLS, 50-FEET FROM PONDS PERMANENT WATER SURFACE ELEVATION, 15-FEET FROM EMBANKMENTS OR CUTS 2 FEET DEEP OR GREATER, AND 10-FEET FROM PROPERTY LINE. 3. A WELL PERMIT WILL BE REQUIRED FROM WAKE COUNTY ENVIRONMENTAL SERVICE AS PART OF THE BUILDING PERMIT PROCESS. ONCE THE PERMIT HAS BEEN OBTAINED, A CERTIFIED WELL CONTRACTOR SHALL INSTALL THE WELL IN ACCORDANCE WITH THE PERMIT. ONCE THE WELL IS CONSTRUCTED, A CERTIFIED PUMP INSTALLER SHALL INSTALL THE PUMP AND COMPLETE THE WELLHEAD CONSTRUCTION. SITE LEGEND - - -000- - - EXISTING CONTOUR LINE 000 PROPOSED CONTOUR LINE PROPOSED CURB AND GUTTER + 381.50 PROPOSED SPOT ELEVATION - - - EASEMENT LINE SS PROPOSED SANITARY SEWER W PROPOSED WATER LINE UGE PROPOSED UNDERGROUND ELECTRICAL LINE T PROPOSED TELEPHONE LINE PROPOSED STORM PIPE ® PROPOSED RIP -RAP PROPOSED STORM DRAIN FLOW 0 CO PROPOSED CLEAN OUT 0 PROPOSED UTILITY POLE BW/TW BOTTOM WALL/TOP WALL GRAPHIC SCALE +o 0 20 . -o 80 160 ( IN FEET ) 1 inch = 40 ft. TE: PROJECT: 08/3/07 JENCO CONCRETE PLANT 1 "= 40' JCA J. N. UCJIb1VCU o i q� JCA CHECKED BY CMD 512 THREE SISTERS ROAD WAKE COUNTY, NORTH CAROLINA ATTACHED REFERENCE FILES: JOB NUMBER: SHEET NUMBER: 012858000 C-3 B0/,<-4j),3 /y%33 S'G✓ �IIIII1111 Wi��(II � IIII 111 III \ I I I ( I / 2:1 ' MITS 16F I II I I II 11 \ I I I ( I I SLOPR E ��5 DIS WI BANCL/, / / / E TIN / CIV C V/ 1 A o li/i1i ihl'll l i I 2 tn( 1 ( IilIj11111 �I� \ N` 1 FviUR� / I'iOryl ut ENAN D ' / / / / /2: �, \ / BUIkDIN S�OPE \\� / �Lr:2690/ /2M TEMPORARY CONSTRUCTION # ENTRANCE �7 /TH AP/ i PR CLASS B APRON STOKIE 00 FILLER / FA RIC./ j / / /// / 266 f %\ INS>,TALIL MP6F \ EROSION 6QNTRQL \ \ \ SL LANKT ON\ALI� \ \ SLOPF� GR P TEES;R :HYPO ` \ \ / ' \(SSE t! STE (fHl SHEET) IPS , \ \\ 6> \ 1 I I I I I I \ , 1 \ \ \ \ \ \ I 1 I \ 1 SLOPE • lrr � r / 1 � y^ ( I 1 1 1 \\ \ \ \ � \ t3` \ \ I RR R I ry OL I ( I j I I I ( \ \ \ ! •4 ' 1 1 \ \ \ \ \ ` \ \ \ %'i i i� / . // / / OFF SITE DRAINAGE i I� I III I I \ �;� --1----�---► , 1 I �� \ \ \ \ \ o \ _ - / q) � I III I I � \ I I I � \ \ � \ \ \ \\ �,r t�1T��W/'! t- Ic QD 1 I I ( / I _ �' RBANCE, III III I I I I/ I I \ �� / I 2 5 -MSTOM SEDIMENT BASF /#3 SHALE. BE CLEANED 91, SILK ;Y�FP% ACCUMULATM SEDIMENT 5 PRo�p BEFORE CONVERTING OI 1 1 1 l 'RERMANENT WET DETENTION / POND. to rb to I IIII I I I I I I I/ \ 16- EMERGENCY N I \ SPILLWAY LEV 263.00\ // ry lI V �\ 5 �...� / 24"RCP I'I I I II III I �260 l lip I I I i \ I I 1 i INV=257.95 I II111i 260 III \ 1 I IIII _____-._._._ w\ J l I 1� 1 � I MINI i (� \ r (I ll \ �QF PROPOSE \ ` o D, Lqeo I I II ` \ / SEPTIC SYSTEM (DESIGNED BY s&Ec) > l1 I _ 12'x14'x22"\TH24"RCP aRIP RAP APRON. XISTNINV=256.9 CLA§k B STO III I I i I i IIII I / SWAIN GE ON FILTER FABR�C.ZZ \ / P / NC DOT , \ \gyp TRAVERSE STATION / 22 THICK RIP RAP APRON CLASS B / STONE ON FILTER / FABRIC. / /ice /wiz /i � // /j 40'x45'x24" THICK RIP RAP APRON. s; CLASS 1 STONE TEMPORARY SILT ECK ON FILTER FABRIC DAM TO REMAI"NTIL SITE IS STABBED (SEE DETAIL, SHEET C-1) IIII I I iIIiI� \� I I \ \ \ I \/ - 255 -// / XIS�'ING\ D AIAGE\o CP3/ 0/" MP DI�cH INV=246.74' i {//� Q / /// / / 0 PAR / I I I I►III 1 1� / \ �', �\f // //�/ vJ � r I IV i / / I III /IIIIiII M1 /G�� 6'CLF �X I// I I I I I II►+ \ \ \ /i//// ,`�P / NC DOT O / TRAVERSE STATION /j I i/ I / // I \ //�j�/� �pP BY104-3 ci C) REVISED PER WAKE COUNTY AND NC DWQ REVIEW COMMENTS 05/05/08 RTL JJW REVISED FEEDER BIN LAYOUT & ADDED OPERATIONS TRAILER 03/25/08 JCA JJW CONSTRUCTION PLANS 03/12/08 JCA CMD 1 WAKE COUNTY REVIEW COMMENTS 09/28/07 JPK CMD REV. No.: REVISION: DATE: DRAWN BY: CHECKED BY: This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc. Copyright Kimley-Horn and Associates, Inc., 2008 PREPARED IN THE OFFICE OF: � KimleywHorn � and Associates, Inc. P.O. BOX 33068 - RALEIGH, NORTH CAROLINA 27636-3068 PHONE: (919) 677-2000 FAX (919) 677-2050 DISTURBED AREA: 3.75 AC EROSION CONTROL LEGEND - - -000- - - EXISTING CONTOUR LINE -000 PROPOSED CONTOUR LINE PROPOSED CURB AND GUTTER X 381.50 PROPOSED SPOT ELEVATION - - - EASEMENT LINE PROPOSED STORM PIPE ® PROPOSED RIP -RAP �^ ~ PROPOSED STORM DRAIN FLOW - - LIMITS OF DISTURBANCE TEMPORARY SILT CHECK DAM Custom Sediment Basin #3 (Proposed Wet Detention Pond) SURFACE AREA REQUIRED 6,167 SF SURFACE AREA PROVIDED 6,484 SF VOLUME REQUIRED 4,158 CF VOLUME PROVIDED 32,184 CF STORAGE DEPTH 9.0 FT TOP OF BERM 9,147 SF 265.00 EMGY. SPILLWAY LENGTH 16 FT 263.00 BOTTOM OF BASIN 208 SF 254.00 GRAPHIC SCALE 40 0 20 40 so 160 ( IN FEET ) i inch = 40 ft. 40' CONSTRUCTION SEQUENCE 1. SCHEDULE A PRECONSTRUCTiON CONFERENCE WITH THE ENVIRONMENTAL ENGINEER, DEBBIE GREENE (TEL #919-856-7413). OBTAIN A LAND -DISTURBING PERMIT. 2. CLEAR ONLY AS NECESSARY TO INSTALL THE EROSION CONTROL DEVICES ON SHEET C-1 "DEMOLITION AND INITIAL EROSION CONTROL PLAN". INSTALL GRAVEL CONSTRUCTION PAD, TEMPORARY SILT CHECK DAM, TEMPORARY DIVERSIONS, SILT FENCE, SEDIMENT BASINS #1 AND #2 OR OTHER MEASURES AS SHOWN ON THE APPROVED PLAN. SEED TEMPORARY DIVERSIONS, BERMS AND BASINS IMMEDIATELY AFTER CONSTRUCTION. 3. INSTALL TEMPORARY STREAM CROSSING AND BEGIN INITIAL CLEARING. INSTALL BYPASS PIPE SYSTEM PRIOR TO ANY STREAM DISTURBANCE. 4. ONCE INITIAL CLEARING AND BYPASS INSTALLATION ARE COMPLETE, INSTALL SEDIMENT BASIN #3 (FUTURE WET POND), PERMANENT RISER, AND OUTLET AS SHOWN ON THE EROSION CONTROL DETAILS. INSURE THAT THE UPSLOPE DISTURBED AREA IS CAPABLE OF FLOWING INTO SEDIMENT BASIN #3, ADD DIVERSION BERMS AS NECESSARY TO CAPTURE ENTIRE AREA. / 5. CALL DEBBIE GREENE (TEL #919-856-7413) FOR AN ONSITE INSPECTION BY THE ENVIRONMENTAL ENGINEER TO OBTAIN A CERTIFICATE OF COMPLIANCE. 6. COMPLETE CLEARING AND GRUBBING. MAINTAIN DEVICES AS NEEDED. ROUGH GRADE SITE. 7. INSTALL STORM SEWER, IF SHOWN, AND PROTECT INLETS WITH BLOCK AND GRAVEL INLET CONTROLS, SEDIMENT TRAPS OR OTHER APPROVED MEASURES AS SHOWN ON THE PLAN. BEGIN SITE CONSTRUCTION, BUILDING, ETC. 8. STABILIZE SITE AS AREAS ARE BROUGHT UP TO FINISH GRADE WITH VEGETATION, PAVING, DITCH LININGS, ETC. SEED AND MULCH DENUDED AREAS WITHIN FIFTEEN (15) DAYS OF COMPLETION OF ANY PHASE OF CONSTRUCTION. 9. WHEN CONSTRUCTION IS COMPLETE AND ALL AREAS ARE STABILIZED COMPLETELY, CALL DEBBIE GREENE (TEL #919-856-7413) FOR AN INSPECTION BY THE ENVIRONMENTAL ENGINEER. 10. IF SITE IS APPROVED, REMOVE TEMPORARY DIVERSIONS, SILT FENCE, TEMPORARY SILT CHECK DAM, ETC. AND SEED OUT OR STABILIZE ANY RESULTING BARE AREAS. ALL REMAINING PERMANENT EROSION CONTROL DEVICES, SUCH AS 4 VELOCITY DISSIPATORS, SHOULD NOW BE INSTALLED. 11. REMOVE ACCUMULATED SEDIMENT FROM SEDIMENT BASIN #3 AND BEGIN CONVERSION TO A STORMWATER WETPOND f AS SHOWN ON SHEET C-6 "STORMWATER MANAGEMENT DETAILS". BRING WETPOND TO FINAL GRADE, CONTACT PROJECT ENGINEER FOR STORMWATER CERTIFICATION, AND SEED STORMWATER POND AREA UPON CERTIFICATION. 12. WHEN VEGETATION HAS BECOME ESTABLISHED, CALL FOR A FINAL SITE INSPECTION BY THE ENVIRONMENTAL ENGINEER, DEBBIE GREENE (TEL #919-856-7413). OBTAIN A CERTIFICATE OF COMPLETION. TREE PROTECTION FENCE CLIENT: JENCO CONCRETE ASSOCIATES, INC. EROSION CONTROL NOTES: 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH WAKE COUNTY STANDARDS AND SPECIFICATIONS 2. SIDE SLOPES OF 3:1 MAX. SHALL BE USED TO THE EXTENT PRACTICABLE TO TRANSITION TO EXISTING GRADE. 3. EROSION CONTROL MEASURES SHALL BE MAINTAINED AS NECESSARY DURING CONSTRUCTION TO PREVENT SEDIMENT LADEN RUNOFF FROM LEAVING THE SITE. 4. TEMPORARY EROSION CONTROL BLANKET SHALL BE A DEGRADABLE, AND AT A MINIMUM A SINGLE NET BLANKET THAT CAN WITHSTAND A SLOPE OF 2: 1. SEEDBED PREPARATION NOTES: 1. GRADED SLOPES AND FILL - THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE WHICH CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT EXPOSED SHALL, WITHIN 15 WORKING DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. 2. GROUND COVER - WHENEVER LAND DISTURBING ACTIVITY IS UNDERTAKEN ON A TRACT COMPRISING MORE THAN ONE ACRE, IF MORE THAN ONE CONTIGUOUS ACRE IS UNCOVERED, A GROUND COVER SUFFICIENT TO RESTRAIN EROSION MUST BE PLANTED OR OTHERWISE PROVIDED WITHIN 15 WORKING DAYS ON THAT PORTION OF THE TRACT UPON WHICH FURTHER ACTIVE CONSTRUCTION IS NOT BEING UNDERTAKEN. 3. SURFACE WATER CONTROL MEASURES TO BE INSTALLED ACCORDING TO THE PLANS. 4. AREAS TO BE SEEDED SHALL BE RIPPED AND SPREAD WITH AVAILABLE TOPSOIL 3" DEEP. TOTAL SEEDBED PREPARED DEPTH SHALL BE 4" TO 8" DEEP. 5. LOOSE ROCKS, ROOTS, AND OTHER OBSTRUCTIONS SHALL BE REMOVED FROM THE SURFACE SO THAT THEY WILL NOT INTERFERE WITH ESTABLISHMENT AND MAINTENANCE OF VEGETATION. SURFACE FOR FINAL SEEDBED PREPARATION, AT FINISH GRADES SHOWN, SHALL BE REASONABLY SMOOTH AND UNIFORM. 6. IF NO SOIL TEST IS TAKED, FERTILIZER AND LIME SHALL BE ACCORDING TO SEEDING SPECIFICATIONS. 7. IF SOIL TEST IS TAKED, PROVIDE LIME AND FERTILIZER ACCORDING TO THE SOIL TEST REPORT. 8. LIME AND FERTILIZER SHALL BE APPLIED UNIFORMLY AND MIXED WITH THE SOIL DURING SEEDBED PREPARATION. SEEDING Seedbed Preparation: Seeding Schedule: 1. Chisel compacted areas and spread topsoil For Shoulders, Side Ditches, Slopes (Max 3:1): three inches deep over adverse soil conditions, if available. Date Type Planting Rate 2. Rip the entire area to six inches deep. Aug 15-Nov Tall Fescue 300lbs/acre 3. Remove all loose rock, roots and other Nov 1-Mar 1 Tall Fescue & Abruzzi Rye 300lbs/acre obstructions, leaving surface reasonably Mar 1-Apr 15 Tall Fescue 300lbs/acre smooth and uniform. Apr 15-Jun 30 Hulled Common Bermudagrass 25lbs acre 4. Apply agricultural lime, fertilizer and Jul 1-Aug 15 Tall Fescue AND Browntop 125lbs/acre (Tall Fescue) superphosphate uniformly and mix with soil Millet or Sorghum -Sudan 35 Ibs/acre (Browntop Millet) (see mixture below). Hybrids*** 30 Ibs/acre (Sorghum -Sudan Hybrids) 5. Continue tillage until a well -pulverized, firm, reasonably uniform seedbed is prepared four to six inches deep. For Shoulders, Side Ditches, Slopes (3:1 to 2.1): 6. Seed on a freshly prepared seedbed and cover seed lightly with seeding equipment or Date Type Planting Rate cultipack after seeding. Sericea Lespedeza (scarified) 50lbs/acre (Sericeo Lespedeza) 7. Mulch immediately after seeding and anchor Mar 1-Jun 1 and use the following mulch. combinations: 8. Inspect all seeded areas and make necessary repairs or reseedings within the planting Mar 1-Apr 15 Add Tall Fescue 120lbs/acre season, if possible. If stand should be more Mar 1-Jun 30 Or add Weeping Love Grass 101bs acre than 60% damaged, re-establish following Mar 1-Jun 30 Or add Hulled Common 25lbs/acre the original lime, fertilizer and seeding rates. Bermudagrass 9. Consult S&EC Environmental Engineers on Jun 1-Sep 1 Tall Fescue AND Browntop 120lbs/acre (Tall Fescue) maintenance treatment and fertilization after Millet or Sorghum -Sudan 35 Ibs/acre (Browntop Millet) permanent cover is established. Hybrids*** 30lbs/acre Sorghum -Sudan Hybrids) Mixture: Sep 1-Mar 1 Sericea Lespedeza (unhulled- 70lbs/acre (Sericea Lespedeza) Agricultural Limestone 2 tons/acre (3 tons/acre in clay soils) Nov 1-Mar 1 unscarified) AND Tall Fescue AND Abruzzi Rye 120lbs/acre (Tall Fescue) 25lbs/acre Fertilizer 1,000 Ibs/acre - 10-10-10 Superphosphate 500 Ibs/acre - 20% analysis Mulch 2 tons/acre - small grain straw Consult S&EC Environmental Engineers for additional information concerning other Anchor Asphalt emulsion 300 alternatives for vegetation of denuded areas. The above vegetation rates are at gals/acre those that do well under local conditions oth r s d" t b' t' TI TLE: l 3" Tree Protection Area 3• DO NOT ENTER 4" SIGN DETAIL N.LS WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL LETTERS ARE TO BE 3" HIGH MINIMUM, CLEARLY LEGIBLE, AND SPACED AS DETAILED. SIGNS ARE TO BE PLACED NO GREATER THAN 200' ON CENTER. PLACE SIGN AT EACH END OF LINEAR TREE PROTECTION AREA AND 200' ON CENTER THEREAFTER. FOR TREE PROTECTION AREAS LESS THAN 200' IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. WEATHERPROOF SIGN (AS SHOWN ABOVE): POST MAY BE EITHER 4" DIAMETER PINE, SEE NOTES BELOW FOR CONSTRUCTION AND SPACING DATA. 2DIAMETER OAK, OR 1.33 Ib/lf S�-' 5'-0' O.C. MAXIMUM ORANGE, UV RESISTANT, HIGH -TENSILE STRENGTH, �- POLY BARRICADE FABRIC Tree Protection Area DO NOT ENTER z 0 I :r SUBGRADE. NOTES INSTALL TREE PROTECTION FENCE do SIGNAGE PRIOR TO CONSTRUCTION. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. ADDITIONAL SIGNS MAY BE REQUIRED BASED ON ACTUAL FIELD CONDITIONS. EROSION CONTROL PLAN CAq J. AtIft e ee Ing ra a com Ina Ions are possible. *** TEMPORARY: Reseed according to optimum season for desired permanent vegetation. Do not allow temporary cover to grow more than 12" in height before mowing; otherwise, fescue may be shaded out. MIN. 10 GA LINE WARES 8' MAX. VARIABLE AS DIRECTED BY THE ENGINEER FRONT VIEW STEEL POST - WOVEN WIRE FABRIC �_ SILT FENCE GEOTEXTiLE FABRIC 2-1/2 GA. ,IEDIATE GRADE NOS -USE SILT FENCE ONLY WHEN DRAINAGE AREA c FILL SLOPE DOES NOT EXCEED 1/4 ACRE AND NEVER IN 1;, • FOR REPAIR OF SILT AREAS OF CONCENTRATED FLOW a i ; FENCE FAILURES, USE �.. No. 57 WASHED STONE -END OF SILT FENCE NEEDS TO BE TURNED UPHILL �� FOR ANCHOR WHEN SILT GRADE FENCE IS PROTECTING CATCH BASIN. DATE: 08/3/07 HORIZONTAL SCA 1 "=40' VERTICAL SCALE: N/A DRAWN BY. JCA DESIGNED BY: JCA CHECKED BY: CMD PROJECT: - 6" MIN. COVER OVER SKIRT • ANCHOR SKIRT AS DIRECTED BY ENGINEER • SIDE VIEW TEMPORARY SILT FENCE JENCO CONCRETE PLANT 512 THREE SISTERS ROAD WAKE COUNTY, NORTH CAROLINA ATTACHED REFERENCE FILES: JOB NUMBER: 1012858000 NUMBER: C-4 13c)x41�3 /�� 3 y s�' T. 77 - • 1 _ _03 - a i.: '.04 •00 ff �0:3 `.00 .01 05 �.02 .02 .02� ti t•01 �.03 •0� c_06 _.02 .0,1 ` •02 NOTE 1. 10' MAXIMUM BETWEEN CONSTRUCTION JOINTS 15' MAXIMUM BETWEEN CONSTRUCTION JOINTS 64 12' ON MACHINE POURS. 2. 112' EXPANSION JOINT EVERY 90. 3' 3. 3000 PSI CONCRETE MINIMUM STRENGTH AT 28 DAYS. 6' *3' 4. 4' MAXIMUM SLUMP • • , . 5. LIQUID MEMBRANE CURING COMPOUND SHALL MEET • ' THE REQUIREMENTS OF SECTION 1026-2 OF NCDOT 6► •. •► 17- STANDARDS & SPECIFICATIONS FOR ROADS AND • • ` •• STRUCTURES. 6. ALL CONSTRUCTION JOINTS SHALL BE FILLED 24' CURB & GUTTER WITH JOINT FILLER AND SEALER IN ACCORDANCE WITH NCDOT ROADWAY STANDARD DETAIL 846.01. THE JOINT MATERIAL SHALL CONFORM TO SECTION 1028-2 OF NCDOT'S STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES. 181 CURB & GUTTER NOT TO SCALE 1/2- EXPANSION JOINT O MIN. 30 LF INTERVALS 1/2- CONTROL JOINT -BROOM FINISH CONC SURFACE AREA INSIDE OF TOOLED EDGE / TO CREATE PICTURE FRAME EFFECT BROOM FINISH CONC SURFACE MATCH WIDTH SMOOTH TOOLED FINISH AREA INSIDE OF TOOLED EDGE SIDEWALK AROUND ALL EDGES, TYP TO CREATE PICTURE FRAME EFFECT 3000 PSI COMPRESSIVE 6'x6'x6 GUAGE STRENGTH CONCRETE WELDED WARE FABRIC SEE SITE PLAN FOR DIMENSION Y 3' 4 I 3 2- 2� 1. 1/4-/FT 1. CROSS SLOPE .• ..•... �..• • *'If .S•,i• 0.4 T 1/2- PREMOLDED 1/2" CONTROL JOINT EXPANSION JOINT FILLER, ALL EDGES SQUARE. EXPANSION JOINT CONTROL JOINT SECTION CONCRETE SIDEWALK NOT TO SCALE 6" 5'-0" 6" 3* RA 6" 12" 18" CURB & GUTTER �// COMPACTED SUBGRADE A A NOTE: ALL CONCRETE TO BE 3,000 PSI IN 28 DAYS. PLAN SECTION A -A SEE NOTE 1 SIDEWALK 4' STOP BAR SIDEWALK DETAIL SHOWING TYPICAL LOCATION OF SIDEWALK ACCESS RAMPS, PEDESTRIAN CROSSWALKS AND STOP BARS. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC STREET INTERSECTIONS WHERE SIDEWALK 1S REQUIRED. WHEN SIDEWALK IS NOT REQUIRED, CURB IS TO BE DEPRESSED AT ALL RAMP LOCATIONS AS SHOWN ON THIS SHEET. SEE NOTE 1 TYPICAL'N CONCRETE FLUME NOT TO SCALE 4' ST SEE NOTE I TYPICAL SEE NOTE 1 TYPICAL GRASSED AREA SIDEWALK 4' STOP BAR +.- LU-SIDEWALKSEE NOTE I \ TYPICALl�s VARIABLE C 4' STOP BAR SEE NOTE 1 TYPICAL SIDEWALK \�/ I 11 SIDEWALK GRA�EA C `4' STOP BAR�g---•► 4' STOP BAR �GRASSED A SIDEWALK SIDEWALK SEE NOTE I SEE NOTE 1 TYPICAL TYPICAL DETAIL SHOWING TYPICAL LOCATION OF SIDEWALK ACCESS RAMPS PEDESTRIAN CROSSWALKS AND STOP BARS FOR TEE INTERSECTION. 4' STOP BAR B B SIDEWALK SIDEWALK GRASSED AREA GRASSED AREA DEPRESSED CURB & WINGS AT RAMP CONSTRUCTION PLANS 03/12/08 JCA CMD 1 WAKE COUNTY REVIEW COMMENTS 09/28/07 JPK CMD REV. No.: REVISION:-7- DATE: DRAWN BY- CHECKED BY. This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc. Copyright Kimley-Horn and Associates, Inc., 2008 SIDEWALK ACCESS RAMP DUMMY JOINT M �Z 1B- s�es LEGEND AND BORDER -GREEN MAXIMUM BACKGROUND -WHITE PENALTY !250 0 SIGN R SNOW CONE CONCRETE AT TOP - PAINT YELLOW. 6" DIA. STEEL PIPE BOLLARD - FILL WITH PEA GRAVEL CONC. PAINT TWO (2) COATS YELLOW. FINISH GRADE 24" DIA. CONCRETE FOOTING (3000 PSI AT 28 DAY STRENGTH PIPE BOLLARD DETAIL NOT TO SCALE GS 20-37.8 OR R7-ft RESERVED BOTTOM Of SIGNS R7-8 OR R7-6a PARKING R7-8D SIGN APPROVED FOR USE UNDER GENERAL STATUTE 20.37.E SlpN ASEE NOTE *3 ON DUMMY JOINT 5' SIDEWALK GOES HER R7-8DR7-8 FINISHED GRADE SIGN APPROVED FOR USE UNDER GENERAL STATUTE 20.37.5 COLORS: m7 LEGEND AND BORDER -GREEN WHITE SYMBOL ON BLUE BACKGROUND BACKGROUND -WHITE HANDICAPPED PARKING SIGNAGE NOT TO SCALE 112, EXPANSION JOINT p .o GRASS STRIP D BACK OF CURB FACE OF CURB •.• :•�•►'•'1 -•:;♦ ..• * i.•, •�..� •�• w'�1 -•• '• w N• • w� �• A 2' DETECTABLE WARNNG DOMES INSIDE PEDESTRAIN SEE NOTE • L CROSSWALK LIE PEDESTRIAN CROSSWALK DEPRESSED CURB to, MINA" SIDEWALK ACCESS RAMP 6.0' (UNLESS OTHERWISE SPECIFIED) DEPRESSED CURB 2' DETECTABLE STANDARD 2' 6' CURB & GUTTER 4' 1211 AIAXak& SLOPE W�OQOAI �S SIDEWALK ACCESS RAMP • •'• •►•; !' •� SECTION °A -A x 4' CONCRETE FOUNDATION FOR ALL PUBLIC STREET TIE-INS SLOPE 12.1 MAX (6.0' MAX) 12' DEPRESSED CURB 5' SIDEWALK \ - - I - 2' DETECTABLE STANDARD 2'- 6' WARNING DOMES CURB & GUTTER EXPANSION JOINT4' CONCRETE SECTION 'B-B, FOUNDATION FOR RAMPS AT ASPHALT TO ASPHALT STREET TYPE DRIVEWAYS NOTES: OR PRIVATE STREET TIE IN. 1. DETECTABLE WARNING DOMES SHALL COVER 2'-0' LENGTH AND FULL WIDTH OF THE RAMP FLOOR AS SHOWN ON DETAIL. MINIMUM SIZE OF PAVER SHALL BE V X V. 2. OBTAIN 70Y. CONTRAST VISIBILITY WITH ADJOINING SURFACE , EITHER LIGHT ON DARK , OR DARK ON LIGHT SEQUENCE COVERING THE DETECTABLE WARNING AREA. PREPARED IN THE OFFICE OF: Kimley=Horn � I and Associates, Inc. P.O. BOX 33068 - RALEICH, NORTH CAROLINA 27636-3068 PHONE: (919) 677-2000 FAX (919) 677-2050 VARIABLE SLOPE NOT TO EXCEED L12d 161-0. 6-0- 1 4'-0' MIX 1 STANDARD CLUB CURB 6'-0• SIDEWALK STANDARD CURB G ISOMETRIC VIEW HC RAMP DETAILS NOT TO SCALE 4' STANDARD -JOINT CURB SECTION 'C-C' DOUBLE ACCESS RAMP VARIABLE SLOPE NOT TO EXCEED 12d IF 16,-0• 6-0- I 4-0• MIk 1 4'-0' MIN. 6'-0' VAR SLOPES NOT TO EXCEED 12,1 . WN - - -!." 7." SIDEWALK ACCESS RAMP 2' DETECTABLE WARNING DOMES UP NOT TO EXCEED Y. - DEPRESSED CURB SECTION 'D-D" CONCRETE BITUMINOUS SURFACE APACTED BASE COURSE «wnnvi� nw n e• . a• 6 NOTE: 1. ANCHOR RODS TO BE SLEEVED OR GREASED THRU CONCRETE CURBS TO PERMIT RELOCATION OF CURBS. 2. SEE SITE PLAN FOR CURB STOP LOCATIONS. TYPICALLY PLACED 2.5' OFF OF BACK OF CURB 1/2' DIA. STEEL RODS (#4 REBAR) 2.0' MINIMUM LENGTHCONCRETE WHEEL STOP DETAIL NOT TO SCALE R1-1 30" x 30" WHITE ON RED STOP SIGN NOT TO SCALE 6,-0, BACK OF SIDEWALK :� : • !"' TOP OF CURB LINE BACK OF SIDEWALK STOP OF CURB RAMP WIDTH AREA VARIABLE BASE DIAMETER 0.45' R TO 0.70' R 0 0 0 0 0 0 �? (D 0 E) O O TOP DIAMETER OF NC J 0 0 O O O yLESS THAN 50Y TO o NO MORE THAN 65Y i14 0 0 0 0 O OF THE BASE III I DIAMETER 065, 0.9' TO ININ. 1.60 TO 2' 1: ; f .! r'•: •;!•;., ` `-'' • �PRECAST CLASS 'B' .. . w...' •. �..� .. DETECTABLE WARNING CONCRETE DOMES NOTE: ALTERNATE MATERIAL MAY BE USED PROVIDED THE PRODUCT HAS BEEN APPROVED BY THE CITY AND THE MANUFACTURER'S INSTALLATION REQUIREMENTS ARE MET. 6" 4,000 PSI CONCRETE 4- EDGE OF PAVEMENT COMPACTED BASE COURSE SECTION A - A O26" ABC COMPACTED SUBGRADE (95% STANDARD PROCTOR) NOTES: 1. ALL PAVEMENTS, BASES, AND SUBGRADES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST APPLICABLE NCDOT STANDARDS & SPECIFICATIONS. 2. REFER TO GEOTECHNICAL REPORT FOR ADDITIONAL INFORMATION. CONCRETE PAVEMENT NOT TO SCALE I. NORTH CAROLINA GENERAL STATUTE 136-44.14 REQUIRES THAT ALL STREET CURBS BEING CONSTRUCTED OR RECONSTRUCTED FOR MAINTENANCE PROCEDURES, TRAFFIC, OPERATIONS, REPAIRS, CORRECTIONS OF UTILITIES OR ALTERED FOR ANY REASON AFTER SEPTEMBER 1, 1973 SHALL PROVIDE SIDEWALK ACCESS RAMPS FOR THE PHYSICALLY HANDICAPPED AT ALL INTERSECTIONS WHERE BOTH CURB AND GUTTER AND SIDEWALKS ARE PROVIDED AND AT THE OTHER POINTS OF PEDESTRIANS FLOW. IN ADDITION, SECTION 228 OF THE 1973 FEDERAL AID HIGHWAY SAFETY ACT REQUIRES PROVISIONS OF DEPRESSED CURBS ON ANY CURB CONSTRUCTED AFTER JUL Y 1, 1976 WHETHER A SIDEWALK IS PROPOSED INITIALLY OR IS PLANNED FOR A FUTURE DATE. THE AMERICANS WITH DISABILITIES ACT (ADA) OF 1990 EXTENDS TO INDIVIDUALS WITH DISABILITIES COMPREHENSIVE CIVIL RIGHTS PROTECTION SIMILAR TO THOSE PROVIDED TO PERSONS ON THE BASIS OF RACE, SEX, NATIONAL ORIGIN AND RELIGION UNDER THE CIVIL RIGHTS ACT OF 1964. THE ADOPTED SIDEWALK ACCESS RAMPS HAVE BEEN DESIGNED TO COMPLY WITH CURRENT ADA STANDARDS. 2. SIDEWALK ACCESS RAMPS SHALL BE PROVIDED AT LOCATIONS AS SHOWN ON THE PLANS OR AS DIRECTED BY THE ENGINEER. SIDEWALK ACCESS RAMPS SHALL BE LOCATED AS INDICATED IN THE DETAIL HOWEVER, THE LOCATION MAY BE ADJUSTED AS DIRECTED BY THE ENGINEER WHERE EXISTING LIGHT POLES, FIRE HYDRANTS, DROP INLETS, ETC. AFFECT PLACEMENT. AT ALL LOCATIONS, NOT LESS THAN 2 FEET OF FULL CURB SHALL BE PLACED BETWEEN DOUBLE RAMPS. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC STREET INTERSECTIONS WHERE SIDEWALK IS REQUIRED. WHEN SIDEWALK IS NOT REQUIRED, CURB IS TO BE DEPRESSED AT ALL RAMP LOCATIONS. 3. THE WALKING SURFACE SHALL BE SLIP RESISTANT. COLORS FOR THE DETECTABLE WARNING AREA SHALL BE DARK CHARCOAL GRAY FOR CONTRAST WITH LIGHT PATHWAY COLORS AND LIGHT CONCRETE GRAY FOR CONTRAST WITH DARK PATHWAY COLORS. 4. NO SLOPE ON THE SIDEWALK ACCESS RAMP SHALL EXCEED 0.08 (12:I) IN RELATIONSHIP TO THE GRADE OF THE STREET. 5. IN NO CASE SHALL THE WIDTH OF THE SIDEWALK ACCESS RAMP BE LESS THAN 48' HOWEVER, RAMP MAY EXCEED 486. 6. USE CLASS A (3000 PSI) CONCRETE WITH A SIDEWALK FINISH IN ORDER TO OBTAIN A ROUGH NONSKID SURFACE. 7. A V2' EXPANSION JOINT WILL BE REQUIRED WHERE THE CONCRETE SIDEWALK ACCESS RAMP JOINS THE CURB AND AS SHOWN ON THE STANDARD DRAWING. 8. SINGLE OR DIAGONAL RAMPS ARE ONLY PERMISSIBLE FOR NEW CONSTRUCTION. 9. ALL RAMPS MUST CONFORM TO THE NORTH CAROLINA ACCESSIBILITY CODE, SECTION 4.7. CLIENT: tatf� JENCO CONCRETE ASSOCIATES, INC. �o t'a��►� TITLE: , CONSTRUCTION DETAILS 9. DATE: PROJECT: 08/3/07 JENCO CONCRETE PLANT HORIZONTAL SCALE: N/A VERTICAL THREE SISTERS ROAD N �cAALE. DRAWN BY: WAKE COUNTY, NORTH CAROLINA JCA DESIGNED BY- JCA ATTACHED REFERENCE FILES: JOB NUMBER: SHEET NUMBER: CHECKED BY: CMD 1012858000 C-5 .lay. .. L . I' 1 r . .�� .. ..., �.:`:;i'�. f..y L:.,�..1... 'r .. . , ..• ,r ; .r. ¢�',. , v z G rn TOP OF FILL TOP OF FILL TOP OF FILL 0 H-V H} H' Z QQ CO) O r HO '11� ca GROUND LINE H GROUND LINE H GROUND LINE N r" -4 000=Z =�ZD(n "t�nr�u_ur=- 7 ie_t,n=ur_ur�u,_ ru�tu�rr_,n= 7 sn"r_n,_rr,-r„_ nr�rtr=-n_ur= su,_ru=u,prrr_ Lu Lu<�LL 0= _ o O nr it nr L U. " u, ii Q V' z,-,,�r'rl LD. ,fir r ,r, O.D. ES MIN. , LD. r�t UO OW �!7 � Z n, �n T, ,•u NOT LESS THAN 3" O H Q " „r u I=IIEWr= lot to, n •_, n _n r= , n =4 -hi 1 Y H 7 CC 1-1 -t o , '7j� O.D. . O.D. I ROCK � �. �•.��•.•':•. .: ":•".� ��: �'� �:: .'.'':_ aH O O.D.l24 YIN. �1 ��- EARTH W G Z NOT LESS THAN 3" + O.D. /12 YIN. rq nr=ur_n ='0.p '- ur _rr=hr- O.D. 4' NOT LESS THAN fill O.D. + q' AS DIRECTED BY ENGR. NORMAL EARTH FOUNDATION ROCK FOUNDATION o.D.+a' PIPE IN TRENCH UNSUITABLE MATERIAL FOUNDATION 3 TOP OF FILL TOP OF FILL TOP OF FILL m z O =z. ccH MIN. O.D. H YI_N. 0.0 _�__ YIN. O.D. � N MIN. O.D. �_�- MIN. O.D. N MIN. O.D. LL Q H J p = �� �, GROUND LINE ♦ 1 !•L GROUND LINE ,{ Z -, Cl) GROUND LIRE I.D. - I.D. - - I.D. mD - _ur_w=u,_n,_ru „=ur ur=tr,_ni_nt _u, „_rrr8" „=ut=ut�u,_ Z Q M Z="rBn,=,n=q -uF"r_nrgut�uran, .. �..:..,•,},: = N Q0.0./24 YIN. - O.D./12 YIN. •• ••'. • . .: •. v If11 O O.D. cc NOT LESS THAN 3" O.D. NOT LESS THAN 8"ur_nr_ a _ur=nr3 ur_Ur=ut QAS W = 0 d O.D. + 2' ROCK O.D./24 YIN. MIN. O.D. O.D. MIN. O.D. BY DENGINEER IRECTED Z W D Z NOT LESS THAN 3" Q W yi > NORMAL EARTH FOUNDATION ROCK FOUNDATION UNSUITABLE MATERIAL FOUNDATION N r Z PIPE ABOVE GROUND N p t7 SF�APPROVED SUITABLE LOCAL MATERIAL OR SELECT MATERIAL FOR FOUNDATION CONDITIONING GENERAL NOTES: AS DIRECTED BY THE ENGINEER. O O I.D. =THE MAXIMUM HORI20NTAL INSIDE DIMENSION. APPROVED aACKFILL OR SEE SELECT MATERIAL OF SELECT THE APPROPRIATE CLASS AS FOLLOWSS GREATER THAN 30', W ._. 1�1 _ O O.D. =THE MAXIMUM HORI20NTAL OUTSIDE DIMENSION, uFnt= w = " UNDISTURBED EARTH MATERIAL W Z H = THE FILL HEIGHT MEASURED VERTICALLY AT ANY POINT SELECT MATERIAL IN, ALONG THE PIPE FROM THE TOP OF THE PIPE TO THE TOP Compaction requimments for backfifll CLASS IV .OVER 50 FEET OF THE EMBANKMENT AT THAT POINT. shaA be 96% per ASTM D-699. I CLASS III OVER 40 FEET THROUGH 60 FEET CLASS II OVER 30 FEET THROUGH 40 FEET .THE CLASS OF SELECT MATERIAL USED FOR AN INDIVIDUAL PIPE INSTALLATION IS BASED ON THE MAXIMUM 'H' WHICH OCCURS ALONG THE PIPE INSTALLATION. A HIGHER CLASS LOOSELY PLACED APPROVED SUITABLE LOCAL MATERIAL OR SELECT MATERIAL SELECT MATERIAL, NOT TO EXCEED CLASS IV, MAY BE USED IN LIEU OF CLASS II OR III. ''.•''''.'`••',:,'�..•• FOR FOUNDATION CONDITIONING AS DIRECTED BY THE ENGINEER.(STONE SELECT MATERIAL WILL NOT BE REQUIRED AROUND THOSE PORTIONS OF /W INDIVIDUAL SHEET 1 OF 1 WILL NOT BE ALLOWED) PIPE INSTALLATION LOCATED UNDER THAT PART OF THE FILL WHERE 'H IS 30 FEET OR LESS SHEET 1 OF 1 300 ■ O Do NOT OPERATE HEAVY EQUIPMENT OVER ANY PIPE CULVERT UNTIL THE PIPE CULVERT HAS IAL300.O BEEN PROPERLY BACKFILLED AND COVERED WITH AT LEAST 3 FEET OF APPROVED MATER. A /SLLL BARS SHALL BE ALL BARS SHALL BE WITH MIN 2" COVER 12" PACED AT 12" O.C. #4 WITH MIN 2 COVER EACH WAY SPACED AT 12" O.C. 2' EACH WAY 41 #4 REBAR, TYP. 24" RCP II 4" MIN INSTALLATION INSTRUCTIONS: II 1. PLACE PIPE IN TRENCH 2. ASSEMBLE PIPE AND POUR I I I ( ANTI -SEEP COLLAR 3. MANUALLY TAMP ALONG FULL LENGTH OF PIPE WITHIN A 2-FOOT DEPTH 4' MIN II I 4. HAND TAMP AROUND COLLAR I NOTE: - ALL COLLARS SHALL BE 3000 PSI CONCRETE AT 28 DAYS. SECTION A -A ANTI SEEP COLLAR A NOT TO SCALE Precast Drainage Structures 2-#6Ry A__..._.._. Reinforcing Bars As Specified Brick Adjustment See Note " Varies Varies t Varies Materials CONCRETE: 4,000 PSI, Type If cement. WALL REINFORCING: per ASTM, C-478 Standard. NOTE: (a) 4" min. wall for 42"e and 5" min. wall for 48'e. AD Reinforcement to be Grade 40, or equivalent, welded wire mesh. " Variable grade adjustment by grade rings or brick as required. 0 42'o or 48"e D A B E STORM DRAIN MANHOLE NOT TO SCALE -No Scale - All dimensions subject to allowable specification tolerances. MZZ CO) H G) _ M o ouzo �OD Z 0 v m m 0 �o M o Z t7 ovo rna=11 r r SHEET 1 OF 2 838.27 ti T1 TOP & BOTTOM loll Z 0 4'-6" T5 @ 6" TOP & BOTTOM 2-"G" 2' 12 r r i"� 2" FILL FACE �r 2 Z a a 1" SZSPA. S IN 'I I�j� FILL FACE II „ "60 V "Zoo I I TOP OF FOOTING I l V1 @ 8" rr ,r "V"@ 1`-loll W J CL H Z - @ WING WALL V@ 11' O O o x �-- z1 1= - PIPE NOT "H" W Q Q LL = Z2 V1 @ V-6n -Sry 1'_ SHOWN "Z" I T4 < U Imo- O CD H @ WING WALL I �� N� f CO tom- LL ZO J H '9 y I l-/ 5„ a - _ - T4 O O 3-N1 N Z i 6 -'IT" i t tp a H Z3 II n LJ� I T4 T 5 @ 6 - 8" W S" r � L 3- N2 1 rr �� 0 � '�-iti,g" INSPA. 0 11" FOOTINGS SECTION - AA W-71�t' SECTION - BB PLAN SEE STD. # 838.45 FOR GENERAL NOTES. BILL OF MATERIAL FOR ENOWALL REINF. STEEL 1 PIPE J BAR SIZE LENGTH NO. EIGHT J B: N ^ ^• Bi #4 5'-6" 4 15 = Q w '1 @ 9" FILL FACE B2 #4 4'-6" 4 12 LL 0 0 Gi #7 8'-8" 2 35 c9 Z o STIR. FACE H1 #4 1 6'-0" 10 40 3 41 0 B2 H2 #4 4' - 0" 4 11 r 3" DIA. DRAINS Ni #5 3'-11" 10 41 o LU w B" ABOVE FLOW LINE N2 #4 3' - 5" 6 14 ML 5 SPA. @ 11" FILL (� ► 2 SPA. @ l'-10L¢" STR. FACE 2-V2, 243, 2-V4 Cc Z 4 FACE 2-H1, 1-H2 3 SPA. @ V-3" FILL H2 T1 #4 12'-8" 6 51 z V O !_N1 FACE 3-H1, 1-H2 V2 FILL FACE1' loll T4 #4 V-6" 6 22 FF-- O Lu H2 1-V2, 1-V3, 1-V4 T5 #4 2'-6" 36 60 W J t It = ELEVATION I va 2 z zt 3'-s" 7" H1 alb"-y r _1� z„ A 3 -3' - 2'-8" fir, "Z" N N Hl� 5'-5" I -i-r 3-N1 3-N2 H2 3,_5„ 1'_1'� I- I I �HK. 5 SPA. @ 11" " H n BARS ,► N rr BARS "Z" BARS WING ELEVATION "H", "N", & "Z" BAR DIMENSIONS ARE OUT TO OUT. V1 V2 V3 #4 #4 #4 6-3 5'- 1 " 3'-11 " s 6 6 25 20 16 0 Z p 0 LLo NOz2 Lu WZ3 V4 #4 2'-9" 6 11 Z1 #5 4'-4" 4 18 Z2 #4 3'-10" 4 10 Z3 #4 3'-2" 4 8 REINF. STEEL LBS. 409 SHEET 1 OF 2 CON./R.C. CU. YDS 5.6 1838.27 10II Z v m T1 TOP & BOTTOM 101, O CAI 2'-1? 'IF 4'-6" T5 @ 6" TOP & BOTTOM 2 r,G 2'�r-r 2- FILL Z 11§;s"- I 5 SPA. @ 11 `r _2rr FILL FACE I) 2" a ~ 0 0 0 FILL FACE Z i D H ]7 "Z" BARS IN fi U r-Q'n-IC/� V1 @ " n u n "V"@ lr-ton HOca m TOP OF FOOTING - LL J DETAIL @ WING WALL 0 0 O = =�DDm c tO 9-z1 PIPE NOT "Hot WaQw= r C0 O - - 22 V1 @ 1'-6" fill NI _ Z' T4 Q U Cr O 10-1 Z H -G -n @ WING WALL �1-�- F- = ~ Z W O' O L-i 1' io - tD CO � CD " iCo n D �C) 5-T4 iV Z H 3-N1J ~HT5 ll @ fi T4 Z3 Br, WU z,0 7 I " 1 3 -N2 3'-0" SECTION - AA o 2'-115 SPA. @ 11" "N" BARS 9" 2'-71¢„ IN BOTTOM OF FOOTING SECTION - BB r" PLAN SEE STD. # 838.45 FOR GENERAL NOTES. BILL OF MATERIAL FOR ENOWALL 9'-0" 4 r REINF. STEEL 1 PIPE ..� -n M _ I BAR SIZE LENGTH NO. EIOIT -� = z Z 2-Gt N W Bi #4 5' -6" 4 15 Q w Y ill t7 - B I 2-Vl @ 9" FILL FACE + io" P PE NOT B2 #4 4'-6" 4 12 LL Q O SH G1 #7 8'-8" Z o 2 35 0 G? Cl) 1-VI STR. FACE SLOPE a H1 #4 6'-0" 10 40 z W 0 r- ' . 2-82 H CO Mfll o , a. H2 #4 4' - 0" 4 11 a W , v -'l 01 N1 #5 3'-11" 10 41 cc ~ O n Z _ *- 0� i� ' 3" 0 DRAINS N2 #4 3'-5" 6 14 9C o- ell ABOVE Z y °D o v1 I - FLOW LINE TAPER DETAIL aoc Z 4 1-4 Tom- - - a 5 SPA. @ 11" FILL 0 O m m v 6 2 SPA. @ 1'-101�" STR. FACE 2-V2, 2-v3, 2-V4 T1 #4 12'-8" 6 51 Z tJ o ioLu 2-N1 FACE 2-H1, l-H2 T4 #4 5'-fill 6 22 Ia- G c0 �j CONST. JT. 2-81 m > - B 3 SPA. @ V-3" FILL H2 T5 #4 2'-6" 36 60 O UJ J O M z ELEVATION FACE 3 H1, 1-H2 Y2 FILL FACE 10/ _Vi #4 6'-3" 6 25 CO Z 0 o Z G) , H2 1-V2, 1-V3, 1-V4 V2 #4 5'-1" 6 20 J O H o v z z zl 3'-9" 7' I V4 V3 #4 3'-11" 6 16 (D U. to m a 31`2" �- �1 ZZ 3,-3„ 7" � va V4 #4 2'-9" 6 11 LZu IZ O= r �, o 6„ Hl Zi #5 4'-4" 4 18 Lu 0- r Z3 2'-ell }� Z2 #4 3'-10" 4 10 CIC N H1� 5'-5" N �HK. �' N uZ„ Z3 #4 3'-2" 4 8 H2 3'-5" tr_ln ��� T4 nHn BARS 11N11 BARS nZn BARS 3-Nl 3-N2 5 SPA. @ 11" REINF. STEEL LBS. 409 SHEET 2 OF 2 "H", "N", & "Z" BAR DIMENSIONS ARE OUT TOT OUT. WING ELEVATION CON./C.S. CU. YDS 5.9 SHEET 2 OF 2 838.27 838.27 v v rn H � mu) 0 �o -n-Iu) 0z� -A x-n>Dm =COC)0 z "o r- -n WOAD CA o H , o � z Z r '= H O r= mo z D m v OF 1 .54 A jA T SOLID COVER SHOWN PERFORATED. PERFORATED AVAILABLE IF SPECIFIED. STATE USE OF SYSTEM ON COVER (I.E.: SEWER, STORM DRAIN, ELECTRICAL) TOP OF COVER B � `B BOTTOM OF COVER PLAN OF FRAME 2'-11/4" V-11%" " \TYPE #1 \ /� � ALTERNATE 2: 4" 2'-01/2" i IV / \ 2'-91/4" / SECTION A -A I 1 L6 / TYPE #2 PLAN OF COVER 1'-11Y2" CIA X cri 3444" II--1-I-- r _ Fes- 4% " 1' -10`3r 8't SECTION B-B MINIMUM WEIGHTS - LBS. FRAME - 180 COVER - 120 TOTAL - 300 SPECIFICATION CLASS 30 IRON MEETING ASTM A-48 z 0o F5. - Qa H Cr 0 V LLJaHZ OOCox = Z QUCC0CD F- OLU 000"¢ Mi 0 9 a. H ao t o aC LL > O 0 v z Q � Z o Q W Z I- 4" o � J O cJ7 Z z a w t HEET 1 OF 1 11 840.54 , 4rx4 CONCRETE RISER BOX TOP=263.50 INV=254.00 1" ORIFICE INV=258.00 - - - 3, PERMANENT POOL ELEV=258.00' BOTTOM EL=254.00 �\ /� r CONTRACTOR TO VERIFY WITH ONSITE GEOTECH IF LINER IS REQUIRED FOR WET DETENTION POND WET DETENTION BASIN DETAIL NOT TO SCALE A 10' WIDE BERM ELEV=265.00 INV=254.00 _I 64 LF 24" RCP ® 0.787. -ANTI-SEEP COLLAR 7'x7'x2.5' DEEP CONCRETE BLOCK FOR ANTI -FLOTATION ATTACHED TO BOTTOM OF RISER EDGE OF WALL SHALL BE FLUSH WITH GUTTER FLOW LINE ELEV=266.00 BAFFLE, TYP. TOP ELEV=266.00 0 0) J NO B �o v M _ 3' WEIR 5' 5' 5' 5' 5' 5' o ELEV=265.60 N 5'x5' RIP RAP PAD ,* CENTERED ON WEIR 4 ' ' SETT°LEMENT CHAMBER B 3' WEIR/A AGGREGATE PIT BOTTOM ELEV=260.00 ELEV=265.70 BOTTOM ELEV=263.00 TOP WALL ELEV=266.00 TOP WALL ELEV=266.0 " PLAN VIEW i� 0 TOP WALL ELEV=266.00 3' WEIR ELEV=265.70 LO I III-� 31 Q PROPOSED GRADE=265.00 W I ►- S Z ( 1 W -co BOTTOM INSIDE AGGREGATE PIT 20' 9' ELEV=263.00 4 CLEANOUT - - - '-- - ` ELEV=261.00 PAIN' T MARKER LINE AT BOTTOM INSIDE 1 CLEANOUT ELEVATION SETTLEMENT CHAMBER ELEV=260.00 SECTION A -A 3' WEIR 266.5-� ELEV=265.60 (BEHIND) 5% 2% 5% TOP WALL ELEV=266.00 L �I J 1 I PROPOSED GRADE=265.00 BAFFLE in I (BEHIND) i I I I 15' 5' CLEANOUT ELEV=261.00 -�- - - - - I BOTTOM INSIDE ELEV=260.00-- 20' --BAFFLE WALL WALL 24" RCP INV=253.50 EDGE OF WALL SHALL BE FLUSH WITH GUTTER FLOW LINE ELEV=266.00 266.5 NOTE: 1. DIMENSIONS SHOWN ARE INSIDE FACE OF WALL TO FACE OF WALL. SEE STRUCTURAL PLANS BY OTHERS FOR WALL THICKNESSES, REINFORCING REQUIREMENTS AND ALL OTHER DESIGN DETAILS. 2. CONTRACTOR SHALL FILL SETTLEMENT CHAMBER WITH PROCESS WATER PRIOR TO RELEASE TO STORMWATER MANAGEMENT POND TO INSURE PROPER OPERATION OF THE FORTRANS UNIT. AGGREGATE PIT & SETTLEMENT CHAMBER DETAILS NOT TO SCALE CLIENT: DATE: PROJECT: PREPARED IN THE OFFICE OF: ��>a 08/3/07 JENCO CONCRETE PLANT 4 REVISED PER WAKE COUNTY & NC DWQ REVIEW COMMENTS 05 05/08 RTL JJW KimleywHorn JENCO CONCRETE ASSOCIATES, INC. ,. HORIZON/A SCALE: CONSTRUCTION PLANS JCA CMD �� L 03/12/08 VERTICAL SCALE: 512 THREE SISTERS ROAD 1 WAKE COUNTY REVIEW COMMENTS 09/28/07 JPK CMD TITLE: DRAWN /A WAKE COUNTY, NORTH CAROLINA and REV. No.. REVISION. DATE: DRAWN BY. CHECKED BYInc.JCA This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose _ _ STORMWATER DESIGNED BY: and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation b P.O. BOX 33068 RALEIGH, NORTH CAROLINA 27636 3068 4. JCA Kimley-Horn and Associates. Inc. shall be without liability t Kimley-Horn and Associates, Inc. y PHONE: (919) 677-2000 FAX: (919) 677-2050 MANAGEMENT DETAILS 4/16(O CHECKED BY: ATTACHED REFERENCE FILES: JOB NUMBER: SHEET NUMBER: �1 (� Copyright Kimley-Horn and Associates, Inc., 2008 SEAL: CMD 012858000 C-V �a�/�3 ��_316 sw • , �_ .. �. i.�.��•e.�ia�. �'_.-1_� .. _L__... -.. _.-.. ____�_.� _ _ ...� - __ � .� _ �.. �-.. 1_S _s ._,�.1�._Li. _. ate._. .-�.� i_f-e .._. __�_L.. INLET SHALL BE PROTECTED (AS NEEDED) FROM EROSION MATH RIPRAP - •• OR EQLAVALE POROUS BAFFLE (TYF 6' PVC W '2% TOP ELEVATION OF STORMWATER 4' MAX DEPTH, 2' MIN GENERAL NOTES 1. DRAW DOWN RISER & BARREL SHALL BE 6' SCH. 40 PVC WITH CLEAN -OUT CAP AND 3/4' HOLES. SEE NOTE 1 FOR NUMBER AND SPACING OF HOLES. 2. THE TARP USED TO PROTECT THE WEIR SHALL BE THE WIDTH SPECIFIED. THE LENGTH OF THE TARP SHALL BE ACCORDING TO AVAILABLE SUPPLY. IF MULTIPLE TARPS ARE TO BE USED, THEN TARPS SHALL BE OVERLAPPED AT LEAST 12'. THE UPSTREAM 12' TARP SHALL OVERLAP THE DOWNSTREAM TARP. THE TARP SHALL BE 50 MIL HEAVY DUTY SILVER TARPAULINS OR EQUIVALENT FOR U.V. RESISTANCE. 3. MAINTENANCE: SEDIMENT TO BE REMOVED AND PROPERLY DISPOSED OF WHEN BASIN IS HALF FULL GRAVEL FILTER AROUND RE DEWATERING CAP TOP OF 6' PVC PIPE (USE 8' PIPE FOR DRAINA GREATER THAN 10 ACRES, 18" FREEBOARD TOP OF BERM 5' MIN ` TARP EMBED TARP 12' 6' PVC (NO / SLOTS) L/5 WASHED STONE FILTER TARP EXTENDS BEY01 TO TOP OF HOLES TOE OF BACK SLOPE SEE NOTE 1 FOR HOLE SPECS DISSIPATER PAD RIP PP EMBED TARP 12' 18' MIN TOP OF DAM TARP PROTECTION 0' MIN DITCH AND BURY TARP EDGE (MIN. 12') WEIR LENGTH SECTION THRU WEIR NOTE-1 ARISER SHOULD BE REPLACED AS NEEDED TO ENSU � RT CAROLINA STANDARD CUSTOM BASIN EFFECTIVE: 01/31/08 INLET SHALL BE PROTECTED (AS NEEDED) FROM EROSION WITH RIPRAP, TARP, MATTING OR EQUIVALENT. COUNT NORTH CAROLIN EFFECTIVE: 01/31/( TARP PROTECTION 1' MIL FREEBOARD BAFFLES I CAP TOP OF TRAS"RACK/'�.�< PVC PIPE /15 WASHED DEWATERBLOCK HOLES STONE FILTER OF PERMANENT TO TOP OF RISER DURING CONSTRUCTION HOLES PHASE OF THE i PROJECT. ANTIL-FLOATATION \ DEVICE ANTI -SEEP COLL ZEE NOTE 1 FOR HOLE SPECS CROSS SECTION CMP OUTLET PIPE ' OF BERM EMERGENCY SPILLWAY HOLE SPECS: DEWATERING HOLES WILL BE INSTALLED IN SETS OF HORIZONTAL RINGS. THE FIRST SET OF HOLES WILL BE SET 6 INCHES FROM THE BOTTOM OF THE RISER. RINGS WILL CONTINUE UP THE RISER IN INTERVALS OF 3 INCHES. HOLES WILL BE 3/4 INCH IN DIAMETER AND WALL BE SPACED EQUALLY AROUND THE RISER. THE NUMBER OF HOLES PER RING WALL EQUAL TO THE DRAINAGE AREA. EXAMPLE A BASIN DRAINING 2.0 ACRES SHOULD HAVE 2 HOLES PER RING EVERY 3 INCHES ON THE RISER PIPE. THE FIRST RING (2 HOLES) WILL BE SET 6 INCHES FROM THE BOTTOM OF THE RISER. NOTE: ROUND DRAINAGE AREA TO THE NEAREST WHOLE NUMBER TO DETERMINE NUMBER OF HOLES. MIN DITOi AND BURY TARP EDGE (MIN. 12') 10' MIN wm LENGTH SECTION THRU WEIR HOLE SPECS: DEWATERING HOLES WALL BE INSTALLED IN SETS OF HORIZONTAL RINGS. THE FIRST SET OF HOLES WALL BE SET 6 INCHES FROM THE BOTTOM OF THE RISER. RINGS WALL CONTINUE UP THE RISER IN INTERVALS OF 3 INCHES. HOLES WILL BE 3/4 INCH IN DIAMETER AND WALL BE SPACED EQUALLY AROUND THE RISER. THE NUMBER OF HOLES PER RING WILL EQUAL TO THE DRAINAGE AREA. EXAMPLE A BASIN DRAINING 2.0 ACRES SHOULD HAVE 2 HOLES PER RING EVERY 3 INCHES ON THE RISER PIPE. THE FIRST RING (2 HOLES) WILL BE SET 6 INCHES FROM THE BOTTOM OF THE RISER. NOTE: ROUND DRAINAGE AREA TO THE NEAREST WHOLE NUMBER TO DETERMINE NUMBER OF HOLES. ELEVATION GENERAL NOTES: 1) BASIN SHOULD BE CLEANED OUT WHEN CAPACITY REACHES AN ELEVATION REPRESENTING THAT THE BASIN IS HALF -FULL. 2) PROVIDE A MINIMUM OF THREE POROUS BAFFLES TO EVENLY DISTRIBUTE FLOW ACROSS THE BASIN, REDUCING TURBULENCE. 3) BAFFLE MATERIAL MUST BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR A SILT FENCE. 4) MOST OF THE SEDIMENT WALL ACCUMULATE IN THE FIRST BAY, SO THIS SHOULD BE READILY AVAILABLE FOR MAINTENANCE. 5) THE TARP USED TO PROTECT THE WEIR SHALL BE THE WIDTH SPECIFIED. THE LENGTH OF THE TARP SHALL BE ACCORDING TO AVAILABLE SUPPLY. IF 300% MULTIPLE TARPS ARE TO BE USED, THEN TARPS SHALL BE OVERLAPPED AT LEAST 12". THE UPSTREAM 12' TARP SHALL OVERLAP THE DOWNSTREAM TARP. THE TARP SHALL BE 50 MIL HEAVY DUTY SILVER TARPAULINS OR ;IPATER PAD PATER EQUIVALENT FOR U.V. RESISTANCE. P RAP 6) DURING THE CONSTRUCTION PHASE OF THE PROJECT, PERMANENT STORMWATER RISER SHALL ONLY DEWATER FROM THE TOP OF PIPE. 7) POND SHALL NOT BE CONVERTED FOR SMRMWATER USE UNTIL APPROVED BY ENVIRONMENTAL ENGINEER. STANDARD CUSTOM BASIN ATTACHED TO PERMANENT RISER CONSTRUCTION PLANS 03/12/08 JCA CMD 1 WAKE COUNTY REVIEW COMMENTS 09/28 07 JPK CMD REV. No.: REVISION: DATE: DRAWN BY: CHECKEDBY: This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Hom and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc. Copyright Kimley-Horn and Associates, Inc., 2008 PREPARED IN THE OFFICE OF: TOP OF MUST BE ABOVE T THE WAS STEEL FENCE POST WIRE FENCE HARDWARE CLOTH FILTER OF #57 WASHED STONE BURY WIRE FENCE AND HARDWARE CLOTH 17 A couN NORTH CAROLIN EFFECTIVE: 01/31/08 3' FILTER FABRIC ON GROUND ♦' UIM - I SILT FENCE STEEL FENCE POST SET MAX 2' APART 4- MIN. TB' INTO SOIJ GROUND NOTES: 1. REMOVE SEDIMENT WHEN HALF OF STONE OUTLET IS COVERED. 2. REPLACE STONE AS NEEDED TO ENSURE DEWATERING. BURY 6' OF UPPER EDGE OF FILTER FABRIC IN TRENCH SECTION VIEW STANDARD SILT FENCE OUTLET NOTES: 1. TEMPORARY DIVERSION DITCH TO BE USED TO INTERCEPT FLOW AND/OR DIVERT TO A SEDIMENT CONTROL MEASURE OR BMP. 2. SILT SHALL BE REMOVED WHEN DITCH IS ONE-HALF FULL. 3. DITCH SHALL BE RECONSTRUCTED WHEN DAMAGED BY EQUIPMENT OR COVERED BY FILL. 4. STABILIZE DIVERSION DITCH BERM WITH TEMPORARY SEEDING, MULCH WITH TAC, AND/OR EROSION CONTROL NETTING. 2' MIN. I I- WASTE MATERIAL -COMPACT, ' i I= F/ SEED & MULCH AFTER VAR. CONSTRUCTION OF DITCH _ Op� 2' 10' 0 V- 2' ,� �P� (-I I I -I I,— III -III -III III III I I -III-III-' � � �' I -III- III III III III III III I I I 12" CROSS SECTIONAL VIEW COUN °R'�°`�°' STANDARD TEMPORARY DIVERSION DITCH EFFECTIVE: 01/31/08 PLAN VIEW FENCE AA BURIED 11 6"X6" TRENCH, BACKFILLED AND COMPACTED 1 SECTION VIEW AT OPENING COUNT OR17i CAROLIN EFFECTIVE: 01/31/08 NOTES: 1. BAFFLE MATERIAL SHOULD BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR SILT FENCE. 2. MOST OF THE SEDM ENT WILL ACCUMULATE IN THE 1ST BAY, WHICH SHOULD BE READILY ACCESSIBLE FOR MAINTENANCE. 3. PROVIDE 3 BAFFLES (USE TWO IF LESS THAN 20 FEET IN LENGTH). PROVIDE 5 BAFFLES FOR DRAINAGE AREAS GREATER THAN 10 ACRES. 4. BAFFLE SHALL BE 700 G/M2 COIR EROSION BLANKET. 5. TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE BERMS 6. INSPECT BAFFLES FOR REPAIR ONCE A WEEK AND AFTER EACH RAINFALL SUPPORT ROPE TO WIRE TO PREVENT SAGGING POST CROSS SECTION SUPPORT POST 24" INTRO BOTTOM OR SIDE COIR MESH OR SIMILAR, STAPLED OR TRENCHED INTO BOTTOM OR SIDE STANDARD BAFFLES DETAIL CLIENT: STAKE TO SUPPORT AT � KimleywHorn JENCO CONCRETE ASSOCIA � and Associates, Inc. ITITLE: P.O. BOX 33068 - RALNGH, NORTH CAROLaVA 27636-3068 PHONE (919) 677-2000 FAX (919) 677-2050 50' MIN. NOTES. BUT SUFFICIENT TO KEEP 1. PUT SILT FENCE OR TREE PROTECTION FENCE UP TO SEDIMENT ON SITE ENSURE CONSTRUCTION ENTRANCE IS USED. 2. IF CONSTRUCTION ON THE SITES ARE SUCH THAT THE MUD .� ' ;'.i ` : ; `• ' ;, IS NOT REMOVED BY THE VEHICLE TRAVELING OVER THE • t.. STONE, THEN THE TIRES OF THE VEHICLES MUST BE WASHED `2"-3" STONE TO BE USED:':' = 25' OR WIDTH OF BEFORE ENTERING THE PUBLIC ROAD. EXISTING .-"--:(SURGE STONE OR RAILROAD PROPOSED STREET, ROADWAY -BALLAST)-.:-::!.-*.-...." , :?•;;:'.,;',.:.: WHICHEVER IS 3. MAINTAIN GRAVEL PAD IN A CONDITION TO PREVENT MUD OR t;':•'- `'• `, °� -*.:': '•�:' GREATER. SEDIMENT FROM LEAVING CONSTRUCTION SITE. ENTRANCE WILL REQUIRE PERIODIC REMOVAL OF SEDIMENT -LADEN STONE AND REPLACEMENT WITH FRESH STONE. PLAN VIEW 35' MIN. 15' MIN. EXISTING ROADWAY t ` 6" MIN _. _ ..,.. .. .. .. .. - Wx FABRIC UNDER STONE CROSS SECTION A C97L OUNT NORTHCAROLIN STANDARD CONSTRUCTION ENTRANCE EFFECTIVE: 01/31/08 NEW CONSTRUCTION 12" MIN. NOTES: 1. L = THE LENGTH OF THE RIPRAP APRON. 2. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" (INCHES). 3. IN A WELL-DEFINED CHANNEL EXTEND THE APRON UP THE CHANNEL BANKS TO AN ELEVATION OF 6" (INCHES) ABOVE THE MAXIMUM TAILWATER DEPTH OR TO THE TOP OF THE BANK, WHICHEVER IS LESS. 4. A FILTER BLANKET OR FILTER FABRIC SHOULD BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. • �,.� • • i • • • •' I ME All" I .'ail. '>�+✓�n%i :tr +� A�� ' � W/A � `i��� �T•0�� • �'�.r� --��� . L�1 .v I • • • A COUNT NORTTi CAROLIN EFFECTIVE: 01/31/08 TES, INC. EROSION CONTROL DETAILS •:.� :: ;•FLOW `:,�:.. ELEVATION - EARTH FILL COVERED BY LARGE ANGULAR ROCK COARSE AGGREGATE O OQ�O p 0.00 000 ° 0° Cp ' .aD 8 00 00 oO 0 "--o O o 0.00 0 0 0 0 0 . ° o O 0j . O 0 p°00'QO 0 0a o0 00 000 o O 'O 00 00. p OO 0 o.op 0 OO O o 0 0 0 00 0 0 Oo.. ° 0 °o o. 00 Oo p a0 0 0 O o b 0 O 0 O. O .p O 0 O O O g 0 0 4 0� O po.0 0 O O O 00 a° O 0 0 0 0 0 'O 0 00, Q 00 O 00 0 °0• 0 ° 0' O ° 0 00 0 O O• °O o 0. 09-0• °'• o° ° O O o -00 O 0p0 00 0 0 0 00 Qo 0 o 0000 0 0 0a0o °OQO p.0 0'0° o ° ° 0 00 0 0 0 0 0 0 'o o• O 0 0 O 0-0 °0 ° 0° ° O o O O b•0 00 O O o 0 O 0 00000 0p00•°0 °O° O0o 000 0000 °00O' 0°0Oob 00.0O a. �0 O �00 0.00.000000 0o 0. 0 �00 0 0. p a.0 00 Op0 0. 25' 25' MINIMUM : STREAM CHANNEL:- TOP OF BANK ' _ ' "r MINIMUM TOP OF BANK PLAN STANDARD TEMPORARY STREAM CROSSING DATE: PROJECT: sF 08/3/07 JENCO CONCRETE PLANT �f°+e HORIZONTAL SCALE: 9 �L N/A VERTICAL SCALE: 512 THREE SISTERS ROAD N/A DRAWN BY: WAKE COUNTY, NORTH CAROLINA 1?JCA DESIGNED BY: 9�i9�♦� CHECK DCBY: ATTACHED REFERENCE FILES: JOB NUMBER: SHEET NUMBER: CMD 012858000 Cj - % 98oX4- l �23 3 7 sIA✓