Loading...
HomeMy WebLinkAboutNCG140091_MONITORING INFO_20190509STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. 1 y n u 1 DOC TYPE ❑ HISTORICAL FILE MONITORING REPORTS DOC DATE YYYYM M DD PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 FACILITY NAME: Chandler Concrete Company ROXBORO Plt#.607 PERSON COLLECTING SAMPLES: NO FLOW - OWENZEC°, IV'' MAY CERTIFIED LABORATORY: Lab # 9 2019 LIMIT VIOLATIONS? YES ❑ NO ® GEN l rtAtr FILES pV!!� i�CTtON Part A: Wastewater Monitoring Requirements 1 QTR f0- Orig - State 0 Copy - State 0 Copy -- Plant 0 Copy - File SAMPLE COLLECTION YEAR: 2019 SAMPLE QUARTER: ®Jan -March ❑April -June ❑Jul -Sept ❑Oct -Dec COUNTY: PERSON PHONE NO. (336) 226-1181 ADD TO LISTSERVE? ❑YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C OPTIONAL INFO: Outfall No. Date Sample Collected' (mm/dd/yr) Type of Wastewater (VE, RM, MD) 2 pH (standard) Total Suspended Solids (mg/L) Settleable Solids (mL/L) Non -Polar Oil & Grease using method 16645GT-HEM6 (mg/L) Discharge Duration (minutes) Total Flow {gallons/day) - 6-93,4 303,5 53 (15 )6 1 NO FLOW VE RM MD - - N/A N/A - N/A ' If wastewater systems have not discharged in this quarter— report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 'If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DEMLR RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. s TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for,all other water classifications. ` Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. ' Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 70,10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DEMLR. If the permittee cannot obtain a Summer 70,10 flow for the receiving waters at the discharge location, the permittee shall notify DEMLR, and the DEMLR Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 8/1/2017-06/30/2022 Last Revised 07/27/17 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Resources Attn: DWR Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information -submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submg false information, including the possibility of fines and imprisonment for knowing violations." ture of Permittee) Permit Date: 8/1/2017-06/30/2022 Last Revised 07/27/17 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT No. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 FACILITY NAME: Chandler Concrete Company ROXBORO Pit# 607 PERSON COLLECTING SAMPLES: MIKE OWEN — — CERTIFIED LABORATORY: Lab # [Grab your reader's attention with a great quote from the document or use this space to emphasize a key point. To place this text box anywhere on the page, just drag it.) LIMIT VIOLATIONS? YES ® NO ❑ Part A: Wastewater Monitoring Requirements 4 QTR ,1' 4rig - State 0 Copy - State 0 Copy - Plant 0 Copy - File SAMPLE COLLECTION YEAR: 2018 SAMPLE QUARTER: ❑Jan -March ❑April -June ❑Jul -Sept ®Oct -Dec COUNTY: PERSON PHONE NO. (336) 226-1181 ADD TO LISTSERVE? []YES ENO EMAIL: DISCHARGING TO CLASS: [:)SA ❑HQW ❑PNA ❑Trout ®Other: C OPTIONAL INFO: RECEIVED JAN 2 3 2019 CENTRAI ;:It c, Outfali No. Date Sample Collected' (mm/dd/yr) Type of Wastewater (VE, RM, MD)' pH (standard) t R SEA Total Suspended Solids (mg/L) 10N Settleable Solids (mL/L) Non -Polar Oil & Grease using method 1664 SGT-HEM6 (mg/L) Discharge Duration (minutes) Total Flow (gallons/day)' - 6-93.4 303,5 53 (15)6 - 1 11/15/18 VE RM MD 8.2 63.1 N/A N/A 60+ N/A Discharge was result of rain event. - Sample Taken - Did not meet collection criteria Rare discharge event, recycle pump was out of service, (repairs completed the following day). Very low flow at outfall, took more than a minute to collect sample bottle, may have contributed to elevated TSS. Basin was clean/clear. t more lfwastewatE Report the a 'if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DEMLR RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.Li, for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. s TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. ' Flow rate can be measured continuousfy or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DEMLR. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DEMLR, and the DEMLR Regional office may require an annual flow report on a case -by -case basis. Permit Date: 8/1/2017-06/30/2022 Last Revised 07/27/17 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY INCLUDING ALL "NO FLOW" "NO DISCHARGE" WITHIN 30 DAYS OF RECEIPT OF SAMPLE OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Resources Attn: DWR Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUSTSIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant pena lties for Vbmitting false information, including the passibility of fines and imprisonment for knowing violations." (Signature of Permi Permit Date: 8/1/2017-06/30/2022 ,� 1"�4 4 (D te) Last Revised 07/27/17 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 FACILITY NAME: Chandler Concrete Company - ROX ORO.PIt!# 607 PERSON COLLECTING SAMPLES: NO FLOW - OWENRECEI VED CERTIFIED LABORATORY: Lab # NOV 0 6 2018 LIMIT VIOLATIONS? YES ❑ NO ® CENTRAL FILES DWR SECTION Part A: Wastewater Monitoring Requirements 3QTR / Orig — State 0 Copy — State 0 Copy — Plant 0 Copy - File SAMPLE COLLECTION YEAR: 2018 SAMPLE QUARTER: ❑Jan -March ❑April -June ®Jul -Sept ❑Oct -Dec COUNTY: PERSON PHONE NO. (336) 226-1181 ADD TO LISTSERVE? ❑YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C OPTIONAL INFO: Outfall No. Date Sample Collected � (mm/dd/yr) Type of Wastewater (VE, RM, MD) z pH (standard) Total Suspended Solids (mg/L) Settleable Solids (mL/L) Non -Polar Oil & Grease using method 1664SGT-HEM6 (mg/L) Discharge Duration (minutes) Total Flow (gallons/day) - - 6-93-4 3 03,s 53 (15 )6 1 NO FLOW VE RM MO - - N/A N/A - N/A_ ' If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (Rl Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 'if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DEMLR RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. ' TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 ml for Trout and PNA waters, and 30 mg/L for all other water classifications. ` Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. ' Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50%of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DEMLR. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DEMLR, and the DEMLR Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 8/1/2017-06/30/2022 Last Revised 07/27/17 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE(OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO_ Division of Water Resources Attn: DWR Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUSTSIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penaity of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the persona r persons whom a nage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for Aitting false information, including the possibility of fines and imprisonment for know}ng violations." (Signature of Permittee) Permit Date:B/l/2017-06/30/2022 /v 2 ( atej Last Revised 07/27/17 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT No. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 FACILITY NAME: Chandler Concrete Company ROXBORO Plt# 607 2 QTR �0 Orig - State 0 Copy - State 0 Copy - Plant 0 Copy - File SAMPLE COLLECTION YEAR: 2018 SAMPLE QUARTER: ❑Jan -March ®April -June ❑Jul -Sept ❑Oct -Dec PERSON COLLECTING SAMPLES: NO FLOW - OWEN COUNTY: PERSON CERTIFIED LABORATORY: Lab# REC EIVEPHONE NO. (336) 226-1181 ADD TO LISTSERVE? ❑YES ®NO EMAIL: LIMIT VIOLATIONS? YES [:]NO ® AUG 0 9 2018 DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C CENTRAL FILE$OPTIONAL INFO: Part A: Wastewater Monitoring Requirements IiUlR ~�r" rind Outfall No. Date Sample Collected a (mm/dd/yr) Type of Wastewater (VE, RM, MD) z pH (standard} Total Suspended Solids (mg/L) Settleable Solids (ml./L} Non -Polar Oil & Grease using method 1664SGT-HEM6 (mg/L) Discharge Duration (minutes) Total Flow 7 (gallons/day] - 6-93,4 303,3 53 (15)6 - 1 NO FLOW VE RM MD - - N A N/A - N/A ' If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. 7 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 'If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DEMLR RO staff notifies you to continue monitoring. pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224, Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DEMLR. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DEMLR, and the DEMLR Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 8/1/2017-06/30/2022 Last Revised 07/27/17 Page 1 of 2 MAL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT _END OF MONITORING PERIOD IN CASE OF "NO FLOW") T0: Division of Water Resources Attn: DWR Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUSTSIGN THIS CERTIFICATION FORANY INFORMATION REPORTED: "i certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons whom a nage the system, or those persons directly responsible for gathering the inf mation, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submig false information, including the possibility of fines and imprisonment for knowing violations." 7 3J 14' (Signatureof"Permittee) / / (DPeJ Permit Date: 8/1/2017-06/30/2022 Last Revised 07/27/17 Page 2 of 2 PROCESS WASTEWATER- Quarterly" Discharge -Monitoring Report GENERAL PERMIT NO. NC6140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 91 FACILITY NAME: Chandler Concrete Company - ROXBORO Plt# 607 PERSON COLLECTING SAMPLES: NO FLOW - OWEN ; ECEIDER CERTIFIED LABORATORY: Lab # V LJ LIMIT VIOLATIONS? YES ❑ NO ® FEB 0 5 2013 CENTRAL FILES Part A: Wastewater Monitoring Requirements DWR SECTION 4 QTR Orig — State 0 Copy — State 0 Copy — Plant 4 Copy - File"'' SAMPLE COLLECTION YEAR: 2017 SAMPLE QUARTER: ❑Jan -March ❑April -June ❑JUI-Sept ®Oct -Dec COUNTY: PERSON PHONE NO. (336) 226-1181 ADD TO LISTSERVE? []YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA []Trout ®Other: C OPTIONAL INFO: Outfall No. Date Sample Collected} (mm/dd/yr) Type , RMWastewater MD) (VE, , (standard) n d Total Suspended Solids (mg/L) Settleable Solids (mL/L) Non -Polar Oil & Grease using method 1664SGT-HEM& (mg/L) Discharge Duration (minutes) Total Flow 7 igallons/day} - - - 6-93.4 303,5, 53, (15)6 _ 1 NO FLOW VE RM MD - - N/A N/A - N/A -> 'If wastewater systems have not discharged in this quarter— report "No -Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 31f an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DEMLR RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. s TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L forTrout and PNA waters, and 30 mg/L for all other water classifications. e Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. 'Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall beset to 50%of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DEMLR. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DEMLR, and the DEMLR Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 8/1/2017-06/30/2022 Last Revised 07/27/17 - Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: - Division of Water Resources Attn: DWR Central Files 7_ 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUSTSIGN THIS CERTIFICATION FORANYINFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete.. I am aware that there are significant penalties for bmitting false information, including the possibility of fines and imprisonment for knowing violations." ' XIIIS (Signature of Permit e (Dat94 Permit Date: 8/1/2017-06/30/2022 Last Revised 07/27/17 Page 2 of 2 ' -PRQCESS'-WASTEWATEft' Quarterly DischargeilVlonitoring` Report ': GENERAL PERMIT No. NCG140000 3QTR CERTIFICATE OF COVERAGE NO. NCG14 0 0 91 FACILITY NAME: Chandler Concrete Company- ROXBORO Plt# 607 PERSON COLLECTING SAMPLES: NO FLOW - OWEN RECEIVED CERTIFIED LABORATORY: Lab # LIMIT VIOLATIONS? YES ❑NO® NOV 02 UP CENTRAL FILES Part A: Wastewater Monitorine Reauirements DWR SlFf'Ti!nn1 Odg —State 0 Copy- State' . 0 Copy.:- Plant, 0 Copy - File SAMPLE COLLECTION YEAR: 2017 - r SAMPLE QUARTER: ❑Jan -March ❑April -June ®Jul -Sept ❑Oct -Dec COUNTY: PERSON PHONE NO. (336) 226-1181 ADD TO USTSERVE? DYES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA []Trout ®Other. C OPTIONAL INFO: Non -Polar Date Sample Type of Wastewater pH Total Suspended Settleable Oil & Grease Discharge Total Flow Outfall No. Collected' Z (VE, RM, MD) (standard) Solids Solids using method Duration (mm/dd/yr) (mg/L) (mL/L) 1664SGT-HEM e (minutes)(gallons/day) .. 1. (mg/L) r. n 6-93'4 303.5, S3 - (15)6 1 NO FLOW VE RM MD - - . N/A N/A - N/A 'If wastewater systems have not discharged in this quarter —report "No Flow" or "No Discharge" here. Please make'sure to mark the sample quarter above. • z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 31f an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DEMLR RO staff notifies you to continue monitoring. b pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. 7 Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DEMLR. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DEMLR, and the DEMLR Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 8/1/2017-06/30/2022 Last Revised 07/27/17 Page 1 of 2 MAIL ORIGINAL AND.ONE COPY OF.THIS ANNUAL. SUMMARY (INCLUDING.ALL "NO FLOW.", "NO DISCHARGE") WITHW-30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: f -- - - -- Division of Water Resources Attn: DWR Central Files 1617.Mail Service Center Raleigh, North Carolina 27699-1617 (919)•807-63747. YOU MUSTSIGN THIS CERTIFIC4TION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for -sub .• - tingfalse information, including the possibility of fines and imprisonment for knowing violations." _ _ - — v Z` ! - - (ignature of Permittee) r (D ej Permit Date: 8/1/2017-06/30/2022 Last Revised 07/27/17 Page 2 of 2 STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 FACILITY NAME: Chandler Concrete Co. — Roxboro PIt. 607 PERSON COLLECTING SAMPLES: CERTIFIED LABORATORY:Pace Analytical Lab #633 OPTIONAL INFO: Part A: Stormwater Monitoring Requirements SAMPLE COLLECTION YEAR:2017 SAMPLING PERIOD: ❑ July -December FORM �, Orig — State 0 Copy — State 0 Copy -- Plant 0 Copy - File ® January -June COUNTY Person PHONE NO. (336) 599 - 8343 ADD TO LISTSERVE? ❑YES ❑NO EMAIL: _ DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout Mother: C Outfall No. Date Sample Collected (mo/dd/yr OR NO FLOW)' pH (Standard Units) TSS (mg/L) Event Duration (minutes] Total , Rainfall (in} In Tier 2 Monthly Monitoring? (y/n) # of Months in Tier 2 Sampling' - - 6-92 1002.3 2 NO FLOW N N/A a1vED JUL 2 4 2017 rr_r,-mot = i r+Lt 1 If "NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here. Please make sure to mark the sample period above. 2 If a value is in excess of the benchmark, or outside the benchmark range (for pH), you must implement the Tier 1 or Tier 2 responses in the General Permit. Tier 2 Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range. 3 TSS benchmark values are 100 mg/l, except when discharging to ORW, HQW, Trout, and PNA waters where they are 50 mg/I. For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge. Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 1 of 2 Part 13: Vehicle Maintenance Activity Monitoring Requirements for facilities using > 55 gal of new motor oil/month — averaged over a calendar year. Outfall No. Date Sample Collected (mo/dd/yr)1 pH (standard units) TPH using method 1664ASGT-HEM (mg/L) Total Suspended Solids (mg/L) Event Duration (minutes) Total Rainfall a (in) New Motor Oil Usage (gal/month) In Tier 2 Monthly Monitoring? (y/n) #! of Months in Tier 2 Sampling2 6-97 152 1002,3 - - - N / A - - - No vehicle maintenance performed at facility --- HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES AT ANY ONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES ❑ NO HAVE YOU CONTACTED THE REGION? YES ❑ No ❑ REGIONAL OFFICE CONTACT NAME: Mail Original and one coin of this DMR (including all "No Flow" & "No Discharge" reports) within 30 days of receipt of sample (or at end of monitoring period in case of "No Flow") to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete am aware tha gr r'sgdificant penalties for submitting false information, including the possibility 7ofin/nd imprisonment for knowing violations." (Signature of Permittee) (D te) Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report \0 Copy -State GENERAL PERMIT NO. NCG140000 0 Copy — Plant 0 Copy - File CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 SAMPLE COLLECTION YEAR: 2017 FACILITY NAME: Chandler Concrete Company - Roxboro Pit. 607 SAMPLE QUARTER: ❑Jul -Sept ❑Oct -Dec ❑Jan -March ®April -June PERSON COLLECTING SAMPLES: COUNTY: Person CERTIFIED LABORATORY:Pace Analytical lab #633 PHONE NO. (336) 599 - 8343 ADD TO LISTSERVE? DYES ®NO EMAIL: LIMIT VIOLATIONS? YES ® NO ❑ RECEI EVCHARGING TO CLASS: ❑SA [—]HQW ❑PNA ❑Trout ®Other: C Part A: Wastewater Monitoring Requirements JUL 2 4 2017 OPTIONAL INFO: CPWMA t Outfall No. Date Sample 1 Collected (mm/dd/yr) Type of Wastewater (VERMMD z , ? 0WR Si~CTi pH (standard (standard) ] Zc N Total Suspended Solids (mg/L) Settleable Solids (mL/L] TPH using method 1664A 6 SGT-HEM (mg/L) Discharge Duration (minutes) Total Flow (gallons/day]' - - - fi-93.4 303,5 53 (15)6 - - i NO FLOW VE RM MD N/A No Discharge this Period 1 If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. k pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. ' Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY INCLUDING ALL "NO FLOW" "NO DISCHARGE" WITHIN 30 DAYS OF RECEIPT OF SAMPLE OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly respo 7Bible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware thatpere are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." re of Pe -7 2�1 ?7 (Date) Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 Ong - State 0 Copy - State 0 Copy - Plant 0 Copy - File CERTIFICATE OF COVERAGE NO. NCG14 O O 9 1 SAMPLE COLLECTION YEAR: 2017 FACILITY NAME: Chandler Concrete Company - Roxboro Pit. 607 SAMPLE QUARTER: []Jul -Sept []Oct -Dec ®Jan -March []April -June PERSON COLLECTING SAMPLES: RECEIVED Person CERTIFIED LABORATORY:Pace Analytical Lab #633 RG 1 PHONE NO. (336) 599 - 8343 APR 2 4 2017 ADD TO LISTSERVE? ❑YES ®NO EMAIL: LIMIT VIOLATIONS? YES ® NO ❑ CENTRAL FILES DISCHARGING TO CLASS: [:]SA ❑HQW ❑PNA ❑Trout ®Other: C DWR SECTION OPTIONAL INFO: Part A: Wastewater Monitorine Requirements Outfall No. Date Sample 1 Collected (mm/dd/yr) Type of Wastewater 2 (VE, RM, MD) pH (standard] Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH usingDischarge method 1664A a S (mgg/L)L) Duration (minutes) Total Flow (gallons/day) - - - 6-93'' 303,5 53 (15)6 - - 1 NO FLOW VE RM MD N/A No Discharge this Period If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3lf an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly respon�sible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware thgf ffiere are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." G (Signature of Permittee) Permit Date: 7/1/2010-06/30/2015 4 T (15ate) Last Revised 07/13/11 Page 2 of 2 STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING FORM GENERAL PERMIT NO. NCG140000 Orig - State 0 Copy - State 0 Copy - Plant CERTIFICATE OF COVERAGE NO. NCG 14 0 0 9 1 SAMPLE COLLECTION YEAR:2017 0 Copy - File FACILITY NAME: Chandler Concrete Co. — Roxbor- I�® SAMPLING PERIOD: ® July -December ❑ January -June PERSON COLLECTING SAMPLES: � COUNTY Person CERTIFIED LABORATORY:Pace Analytical Lab #633 FEB � � 2017 PHONE NO. (336j 599 - 8343 OPTIONAL INFO: CENTRAL. FILES ADD TO LISTSERVE? [:]YES [:]NO EMAIL: _ DWR SECTION DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C Part A: Stormwater Monitoring Requirements Outfall No. Date Sample Collected (mo/dd/yr OR NO FLOW)1 pH (Standard Units) TSS (mg/L) Event Duration (minutes) Total 4 Rainfall (in) In Tier 2 Monthly Monitoring? (y/n) # of Months in Tier 2 Samplingz - - 6-92 1002,3- 2 NO FLOW N N/A If "NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here. Please make sure to mark the sample period above. 2 If a value is in excess of the benchmark, or outside the benchmark range (for pH), you must implement the Tier 1 or Tier 2 responses in the General Permit. Tier 2 Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range. 3 TSS benchmark values are 100 mg/I, except when discharging to ORW, HQW, Trout, and PNA waters where they are 50 mg/l. ° For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge. Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 1 of 2 , Part B: Vehicle Maintenance Activity Monitoring Requirements for facilities using > 55 gal of new motor oil/month — averaged over a calendar year. Outfalf No. Date Sample p Collected (ma/dd/yr)1 pH [Standard Units} TPH using method 1664A SGT-HEM (mg/L) Total Suspended Solids (mg/L) Event Duration {minutes} Total Rainfall° (in) New Motor Oil Usage (gal/month) In Tier 2 Monthly Monitoring? [y/n) II of Months in Tier 2 z Sampling 6-92 152 100 ,3 - - - - - - - - N / A - - - No vehicle maintenance performed at facility - - - HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES AT ANY ONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES ❑ NO HAVE YOU CONTACTED THE REGION? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail Original and one copy of this DMR (including all "No Flow" & "No Discharge" reports) within 30 days of receipt of sample (or at end of monitoring period in case of "No Flow") to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly re risible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete am aware that theignifjaKnt penalties for submitting false information, including the possibility of fines jind imprisonment for knowing violations." Z,I / 2 (Signature of Permittee) (Date) / Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 FACILITY NAME: Chandler Concrete Company - Roxboro Pit._607 PERSON COLLECTING SAMPLES: RECEIVED CERTIFIED LABORATORY:Pace Analytical Lab #633 FEB 0 7 2017 LIMIT VIOLATIONS? YES ® NO ❑ CENTRAL FILES DWR SECTION Part A: Wastewater Monitoring Requirements Orig - State 0 Copy - State 0 Copy - Plant 0 Copy - File SAMPLE COLLECTION YEAR: 2017 SAMPLE QUARTER: []Jul -Sept ®Oct -Dec ❑Jan -March ❑April -June COUNTY: Person PHONE NO. (336) 599 - 8343 ADD TO LISTSERVE? ❑YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA []HQW ❑PNA ❑Trout ®Other: C OPTIONAL INFO: Outfall No. Date Sample i Collected (mm/dd/yr] Type of Wastewater (VE, RM, MD)? pH (standard) Total Suspended Solids (mg/L) Settleable Solids [mL/L) TPH usingDischarge method 1664A SGT-NFN16 (mg/L) Duration (minutes) Total Flow gallons/day)' - - - 6-93A 303,5 53 (15)6 - - 1 NO FLOW VE RM MD N/A No Discharge this Period 1 If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. 2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RNI), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. s TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50%of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW","NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that th are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." l� / (Signature of Permittee) i6atey Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 PROCESS WASTEWATER— Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 91 FACILITY NAME: Chandler Concrete Company Roxboro Pit. 607 SAMPLE COLLECTION YEAR: 20 (�6 L / Orig - State 0 Copy - State 0 Copy - Plant 0 Copy - File SAMPLE QUARTER: ®Jul-S t ❑Oct -Dec ❑Jan -March ❑April -June PERSON COLLECTING SAMPLES: COUNTY: Person CERTIFIED LABORATORY:Pace Analytical Lab ##633 RECEI V /E�HONE NO. (336) 599 - 8343 ADD TO LISTSERVE? ❑YES ®NO EMAIL: LIMIT VIOLATIONS? YES ® NO ❑ NOV 0 4 2016 DISCHARGING TO CLASS: [-]SA [-]HQW ❑PNA [-]Trout ®Other. C Part A: Wastewater Monitorins Requirements CENTRAL FILES DWR SECTION OPTIONAL INFO: Date Sample i Type of Wastewater pH Total Suspended Settleable TPH usingDischarge method 1664A Total Flow Outfall No. Collected' (VE, RM, MD]� (standard) Solids Solids S Duration (gallons/day), (mm/dd/yr) (mg/L) (mL/L) (m�LM6 (minutes) - - - 6-9a,o 303 s 53- 1 NO FLOW VIE RM MD N/N le A%— ' ; `w 7 11� ff No Qualifying Discharge observed this Period - 1 If wastewater systems have not discharged in this quarter— report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. 2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. ° pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. 7 Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 028 .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE_ OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 507-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED. "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my Inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware tha ere are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing vinintinns"" WVZ1f""" I of Permittee) Permit Date: 7/1/2010-06/30/2015 / a. L ( (ate) Last Revised 07/13/11 Page 2 of 2 STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING F GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 91 FACILITY NAME: Chandler Concrete Co. - Roxboro Pit. 607 PERSON COLLECTING SAMPLES: CERTIFIED LABORATORY:Pace Analytical Lab #633 OPTIONAL INFO: Part A: Stormwater Monitorine Reauirements SAMPLE COLLECTION YEAR:2016 ORM Orig - State 0 Copy - State 0 Copy - Plant 0 Copy - File SAMPLING PERIOD: ❑ July -December ® January -June COUNTY Person PHONE NO. (336) 599 - 8343 ADD TO LISTSERVE? ❑YES [-]NO EMAIL: _ DISCHARGING TO CLASS: ❑❑❑ SA HQW PNA []Trout ®Other: C Outfall No. Date Sample Collected {mo/dd/yr OR NO FLOW)l PH {standard Units) T55 (mg/L) Event Duration (minutes) Total 4 Rainfall (in) In Tier 2 Monthly Monitoring? (y/n) # of Months in z Tier 2 Sampling - - 6-9 100 ' - - - - 2 NO FLOW N N/A v r _ I C 1 C DWR SEC TION 1 If "NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here. Please make sure to mark the sample period above. If a value is in excess of the benchmark, or outside the benchmark range (for PH), you must implement the Tier 1 or Tier 2 responses in the General Permit. Tier 2 Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range. 3 TSS benchmark values are 100 mg/I, except when discharging to ORW, HQW, Trout, and PNA waters where they are 50 mg/I. For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge. Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 1 of 2 r— Part B: Vehicle Maintenance Activity Monitoring Requirements for facilities using > 55 gal of new motor oil/month — averaged over a calendar year. Outfall No. Hate Sample P Collected (mo/dd/yrjl pH (Standard Units) TPH using method 1664A SGT-HEM (mg/Lj Total Suspended Solids (mg/L) Event Duration (minutes] Total Rainfall° (in) New Motor Oil Usage (gal/month] In Tier 2 Monthly Monitoring (y/n) q of Months in Tier 2 2 Sampling 6-9 15 100 ' - - - - - - - N / A - - - No vehicle maintenance performed at facility --- HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES AT ANY ONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES ❑ NO HAVE YOU CONTACTED THE REGION? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail Original and one coov of this DMR (includine all "No Flow" & "No Discharge" reports) within 30 days of receipt of sample (or at end of monitoring period in case of "No Flow") to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware here re significant penalties for submitting false information, including the possibility a fines nd imprisonment for knowing violations." ;;� 1 /A, (Sig6ature of Permitt ( te) Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 2 of 2 STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING FORM GENERAL PERMIT NO. NCG140000 Orig - State , vCopy - State 0 Copy - Plant CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 SAMPLE COLLECTION YEAR:2016 0 Copy - File FACILITY NAME: Chandler Concrete Co. - Roxboro Pit. 607 SAMPLING PERIOD: ❑July -December ®lanuary-June PERSON COLLECTING SAMPLES: COUNTY Person CERTIFIED LABORATORY:Pace Analytical Lab #633 PHONE NO. (336) 599 - 8343 OPTIONAL INFO: ADD TO LISTSERVE? DYES [—]NO EMAIL: _ DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C Part A: Storrnwater Monitoring Requirements Outfall No. Date Sample Collected Imo/dd/yr OR NO FLOW)1 pH (Standard Units) 7SS (mg/L) Event Duration !minutes) Total a Rainfall (in) In Tier 2 Monthly Monitoring? (y/n) # of Months in Tier 2 Samplings - - 6-9- 2 NO FLOW N N/A ' If "NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here. Please make sure to mark the sample period above. 2 If a value is in excess of the benchmark, or outside the benchmark range (for pH), you must implement the Tier 1 or Tier 2 responses in the General Permit. Tier 2 Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range. 3 TSS benchmark values are 100 mg/I, except when discharging to ORW, HOW, Trout, and PNA waters where they are 50 mg/I. ' For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge. Permit Date; 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 1 of 2 Part B: Vehicle Maintenance Activity Monitoring Requirements for facilities using > 55 gal of new motor oil/month— averaged over a calendar year. OutfaEl No. !e Date Sample Collected (mo/dd/yr}1 pH (Standard Units) TPH using method 1664A SGT-HEM (mg/L) Total Suspended Solids (mg/L) Event Duration (minutes) Total . Rainfall" (in) New Motor Oil Usage (gal/month) In Tier 2 Monthly Monitoring? (y/n} # of Months In Tier 2 z Sampling 6-9 15 100 - - - N / A - - - No vehicle maintenance performed at facility - - - HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES AT ANY ONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES ❑ NO HAVE YOU CONTACTED THE REGION? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail Original and one copy of this DMR f includine all "No Flow" & "No Discharge" reports) within 30 days of receipt of samoie for at end of monitoring period in case of "No Flow") to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly res nsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there ignifi n naI ies for submitting false information, including the possibility of fi es an imprisonment for knowing violations." z- (Signature of Permittee) 61 (D e) Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 2 of 2 PROCESS WASTEWATER -- Quarterly Discharge Monitoring Report GENERAL PERMIT No. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 5 FACILITY NAME: Chandler Concrete Company - Durham Pit. 603 PERSON COLLECTING SAMPLES: Anthony Warash CERTIFIED LABORATORY:Pace Analytical Lab #633 RECEIVED LIMIT VIOLATIONS? YES ❑ NO AUG 01 Z016 Orig - State 0 Copy - State 0 Copy - Plant Copy - File SAMPLE COLLECTION YEAR: 2016 SAMPLE QUARTER: ❑1uI-Sept ❑Oct -Dec Dan -March ®April -June COUNTY: Durham PHONE NO. (919) 598 - 3180 ADD TO LISTSERVE? [-]YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA ®HQW ❑PNA ❑Trout ❑Other: CENTRAL FILES OPTIONAL INFO: Part A: Wastewater Monitoring Requirements DWR SECTION Outfall No. Date Sample Collected' (mm/dd/yr) Type of Wastewater (VE, RM, MD) pH (standard) Total Suspended ,Solids (mg/L) Settleable Solids (mL/L) TPH using method 1664A Sim LJ� Discharge Duration (minutes) Total Flow 7 (gallons/day) - - - 6-93.4 303.3 53 (15)6 - - 1 5/17/16 VE RM MD 8.2 ND ND N/A 50 140 2 5/17/16 VE 7.8 ND ND N/A 60 110 Discharge was resu It of rain event. - SW comingles with Process Water ' If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. Z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. ° pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. 7 Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 - MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW"„ "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 907-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the Information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the Information submitted Is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that ere are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." nature of Permit Date:7/1/2010-06/30/2015 ; 7 112- ate) Last Revised 07/13/11 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT No. NCC3140000 CERTIFICATE OF COVERAGE No-N0G14 0 0 91: FACILITY NAME: Chandler Concrete Company - Roxboro Pit. 607 PERSON COLLECTING SAMPLES: CERTIFIED LABORATORY:Pace Analytical Lab #633 LIMIT VIOLATIONS? YES ® NO ❑ Part A: Wastewater Monitoring Requirements 0 Orig - State 0 Copy - State 0 Copy - Plant 0 Copy - File SAMPLE COLLECTION YEAR: 2-016 SAMPLE QUARTER: []Jul -Sept ❑Oct -Dec ®Jan -March ❑April -June COUNTY: Person PHONE NO. (336) 599 - 8343 ADD TO LISTSERVE? ❑YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA []HQW ❑PNA ❑Trout ®Other: C OPTIONAL INFO: Outfall No. Date Sample i Collected (mm/dd/yr) Type of Wastewater z (VE, RM, MD} pH (standard) Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH usingDischarge method 1664A SGT-HEM' (mg/L) Duration (minutes) Total Flow (gallons/day) - - - 6-93,4 303.s 53 (15)6 - - 1 NO FLOW VE RM MD N/A No Qualifying Discharge observed this Period - MAY — 16 zIf wastewater systems have not discharged in this quarter -- report "No Flow" or "No Discharge" here. Please make sure to mark the sample 6qu�arte' ka66V�'" UNIT Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW' "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly respo a for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that th9e argignificant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permittee] ,� (Date) / Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 J CERTIFICATE OF COVERAGE NO. NCG14 Q 0 9 5 — FACILITY NAME: Chandler Concrete Com an - Durham Pit. 603 PERSON COLLECTING SAMPLES: Anthony Warash CERTIFIED LABORATORY:Pace Analytical Lab #633 LIMIT VIOLATIONS? YES ❑ NO Part A: Wastewater Monitoring Requirements 0 Orig - State 0 Copy - State 0 Copy - Plant 0 Copy - File SAMPLE COLLECTION YEAR: 2016 SAMPLE QUARTER: ❑Jul -Sept ❑Oct -Dec ®Jan -March ❑April -June COUNTY: Durham PHONE NO. (919) 598 - 3180 ADD TO LISTSERVE? []YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA ®HQW ❑PNA ❑Trout ❑Other: OPTIONAL INFO: Outfall No. Date Sample 1 Collected (mm/dd/yr) Type of Wastewater (VERMMD) z , , pH (standard] Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH using method 1664A 6 S (mg/L) Discharge Duration (minutes) Total Flow 7 (gallons/day} - - - 6-93'4 303,5 53 (15)6 - - 1 NO FLOW VE RM MD N/A 2 NO FLOW VE N/A �)�f'iCIIII�P� No Qualifying Discharge observed this Period - MAY-3 O16 11 !! JYY` '6_ �tviv Z If wastewater systems have not discharged in this quarter —report "No Flow or "No Discharge here. Please make sure to mark the samQletquia�rte �I,ab� ieaSQINr; ilNIT Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM}, Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. s TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. 7 Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 028 .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date:7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE-) WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "l certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsiblefor gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that th a are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 1 1-���,4 ,X 1,;2 r, Signature of Permittee) ( ate) Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING FOR GENERAL PERMIT NO. NCG140000 OV Orig-State -fi- 0 Copy - State 0 Copy - Plant CERTIFICATE OF COVERAGE NO. NCG14 O O 9 1 SAMPLE COLLECTION YEAR: 16 0 Copy- File FACILITY NAME: Chandler Concrete Co. — Roxboro Pit. 607 SAMPLING PERIOD: ®July -December ❑January -June PERSON COLLECTING SAMPLES: COUNTY Person CERTIFIED LABORATORY:Pace Analytical Lab #633 PHONE NO. (336) 599 - 8343 OPTIONAL INFO: ADD TO LISTSERVE? []YES []NO EMAIL: _ DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C Part A: Stormwater Monitoring Requirements Dutfall No. Date Sample Collected (mo/dd/yr OR 1 NO FLOW) pH (Standard Units) TSS (mg/L) Event Duration (minutes) Total 4 Rainfall (in) In Tier 2 Monthly monitoring? . (y/n) # of Months in Tier z 2 Sampling - 6-9 100 . - - - - 2 NO FLOW N N/A 1 If "NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here. Please make sure to mark the sample period above. 2 If a value is in excess of the benchmark, or outside the benchmark range (for pH), you must implement the Tier 1 or Tier 2 responses in the General Permit. Tier 2 Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range. 3 TSS benchmark values are 100 mg/l, except when discharging to ORW, HQW, Trout, and PNA waters where they are 50 mg/I. For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge. RECEIVED FEB 0 3 2016 CENTRAL FILES DWR SECTION Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 1 of 2 Part B: Vehicle Maintenance Activity Monitoring Requirements for facilities using > 55 gal of new motor oil/month — averaged over a calendar year. Outfall No. Date Sample Collected 1 (mo/dd/yr) PH (standard Units) TPH using method 1664A SGT-HEM (mg/L) Total Suspended Solids (mg/L) Event Duration (minutes) Total a Rainfall (in) New Motor Oil Usage (gal/month) In Tier 2 Monthly Monitoring? (y/n) #I of Months in Tier 2 Sampling2 6-9 is 100 ' - - - - - - - - N / A - - - No vehicle maintenance performed at facility --- HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES AT ANY ONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES ❑ NO HAVE YOU CONTACTED THE REGION? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail Orieinal and one coov of this DMR fincludine all "No Flow" & "No Discharee" reports) within 30 days of receipt of sample for at end of monitoring; period in case of "No Flow") to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MU5T51GN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly resp Bible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete am aware that th rid ifipe altie r submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) ( atej Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 2 of 2 tate PROCESS WASTEWATER — Quarterly Discharge Monitoring Report 0 Copy -State GENERAL PERMIT NO. NCG140000 0 Copy - Plant 0 Copy - File CERTIFICATE OF COVERAGE N0. NCG14 0 0 9 1 SAMPLE COLLECTION YEARL2OT6 FACILITY NAME: Chandler Concrete Company Roxboro Pit. 607 SAMPLE QUARTER: ❑Jul -Sept ®Oct -Dec ❑Jan -March ❑April -June PERSON COLLECTING SAMPLES: CERTIFIED LABORATORY:Pace Analytical Lab #633 LIMIT VIOLATIONS? YES ® NO ❑ Part A: Wastewater Monitoring Requirements COUNTY: Person PHONE NO.( 336) 599 - 8343 ADD TO LISTSERVE? ❑YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C OPTIONAL INFO: Date Sample 1 Type of Wastewater pH Total Suspended Settleable TPH using method 1664A Discharge Total Flow Outfall No. Collected (VE, RM, MD)' (standard) Solids Solids SGT-NFM6 Duration � (gallons/day) (mm/dd/yr) (mg/L) (mL/L) (mg/L) (minutes) - - - 6-93.4 303.5 53 (15)6 - - 1 NO FLOW VE RM MD N/A FE' D No Qualifying Discharge observed this Period - CEh TRAP` FILES vv bI=C; I t N 1 If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. 2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MO). Report more than one type if the waste -stream is commingled. 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. A pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY {INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsi le for gathering th information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. ;am aware th t e are significant p alties for submitting false information, including the possibility of fines and imprisonment for knowing violations. ( ignature of Permittee) (D el Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 0/ —State PROCESS WASTEWATER — Quarterly Discharge Monitoring Report 0 copy State GENERAL PERMIT NO. NCG140000 0 Copy - Plant 0 Copy - File CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 SAMPLE COLLECTION YEAR-2016r 9-0 A — FACILITY NAME: Chandler Concrete COMDanv - Roxboro Pit. 607 SAMPLE QUARTER: ®Jul -Sept ❑Oct -Dec ❑Jan -March ❑April -June PERSON COLLECTING SAMPLES: COUNTY: Person CERTIFIED LABORATORY:Pace Analytical Lab #633 REtE I V E D PHONE NO. (336) 599 - 8343 ADD TO LI575ERVE? ❑YES ®NO EMAIL: LIMIT VIOLATIONS? YES ®NO ❑ NOV l�l� DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C CENTRAL FILES DWR SECTION OPTIONAL INFO: Part A: Wastewater Monitoring Requirements Outfall No. Date Sample 3 Collected (mm/dd/yrj Type of Wastewater 2 [VE, RM, MD) pH (standard) Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH usingDischarge method 1664A S `L1 Duration (minutes) Total Flo , (gallons/da )' - - - 6-93,4 303.s 53 (15), - 1 NO FLOW VE RM MD N/A No Qualifying Discharge observed this Period - 1 If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. ° pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 5) 5) 9 a Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY INCLUDING ALL "NO FLOW" "NO DISCHARGE" WITHIN 30 DAYS OF RECEIPT OF SAMPLE OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly resp nsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware tF}�t tthere are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." �W7/�- 16 Z)� (Signature of Permittee (D e) Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG 14 0 0 9 1 SAMPLE COLLECTION YEAR:2014-2015 FACILITY NAME• Chandler Concrete Co - Roxboro Pit An7 SAMPLING PERIOD: ❑ July -December FORM Orig - State 0 Copy - State 0 Copy - Plant 0 Copy - File ® January -June PERSON COLLECTING SAMPLES: COUNTY Person �� IVHONE NO. (336) 599 - 8343 CERTIFIED LABORATORY:Pace Analytical Lab #633 OPTIONAL INFO: JUL 3 1 2015 ADD TO LISTSERVE? ❑YES ❑NO EMAIL: _ DISCHARGING TO CLASS: ❑5A ❑HQW ❑PNA ❑Trout ®Other: C Part A: Stormwater Monitoring Requirements CENTRAL FILES Outfall No. Date Sample Collected (mo/dd/yr OR NO FLOW)1 pH (Standard Units} vvvF\ JGV I F TSS (mg/L} I Event Duration (minutes) Total 4 Rainfall (in) In Tier 2 Monthly Monitoring? (y/n) # of Months in Tier 2 2 Sampling - - 6-92 1002, - - - - 2 NO FLOW N N/A i If "NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here. Please make sure to mark the sample period above. z If a value is in excess of the benchmark, or outside the benchmark range (for pH), you must implement the Tier 1 or Tier 2 responses in the General Permit. Tier 2 Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range. 3 TSS benchmark values are 100 mg/I, except when discharging to ORW, HQW, Trout, and PNA waters where they are 50 mg/I. "For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge. Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 1 of 2 Part B: Vehicle Maintenance Activity Monitoring Requirements for facilities using > 55 gal of new motor oil/month — averaged over a calendar year. Outfall No. Date Sample Collected (mo/dd/yr]1 PH [Standard Units] TPH using method 1664A SGT-HEM (mg/L) Total Suspended Solids (mg/0[minutes] Event Duration Total a Rainfall (in] New Motor Oil Usage [gal/month] In Tier 2 Monthly Monitoring? (y/n] I � # of Months in Tier 2 2 Sampling 6-92 152 1002,3 - - - - - - - - N / A - - - No vehicle maintenance performed at facility - - - HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES AT ANY ONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES ❑ NO HAVE YOU CONTACTED THE REGION? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail Orieinal and one coon of this IJMR (including all "No Flow" & "No Discharge" reports) within 30 days of receiot of sample (or at end of monitoring period in case of "No Flow") to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons dir ly resp nsible r gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete am aware re a sig fica t penalties for submitting false information, including the possibility of fi es a imprisonment for knowing violations." (Signature of Permittee) (D te) Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT No. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 FACILITY NAME: Chandler Concrete Company - Roxboro Pit. 607 PERSON COLLECTING SAMPLES: RECEIVED CERTIFIED LABORATORY:Pace Analytical Lab #633 LIMIT VIOLATIONS? YES ® NO ❑ CENTRAL FILES DWR SECTION Part A: Wastewater Monitoring Requirements Orig - State 0 Copy - State 0 Copy -- Plant 0 Copy - File SAMPLE COLLECTION YEAR: 2014-2015 �s SAMPLE QUARTER: []Jul -Sept ❑Oct -Dec ❑Jan -March ®April -June COUNTY: Person r PHONE NO.( BRI 599 - 8343 � ADD TO LISTSERVE? ❑YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA [-]Trout ®Other: C OPTIONAL INFO: Outfall No. Date Sample 1 Collected {mm/dd/yr} Type of Wastewater 2 {VE, RM, MD} pH {standard} Total Suspended Solids {mg/L} Settleable Solids (mL/L) TPH usingDischarge method 1664A 6 SGT-HEM (mg/L) Duration (minutes) Total Flow 7 {gallons/day] - - - 6-93,4 303.s 53 (15)6 - - 1 NO FLOW VE RM MD N/A No Qualifying Discharge observed this Period - 1 If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. 2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. 2 Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW". "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: _ ^ Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." re Permit Date:7/1/2010-06/30/2015 2 r11-r (Cate) Last Revised 07/13/11 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 FACILITY NAME: Chandler Concrete Company _ Roxboro Pit. 607 PERSON COLLECTING SAMPLES: CERTIFIED LABORATORY:Pace Analytical Lab #633 LIMIT VIOLATIONS? YES ® NO ❑ Part A: Wastewater Monitoring Requirements c)-cl5� Orig -State 0 Copy - State 0 Copy - Plant 0 Copy - File SAMPLE COLLECTION YEAR: 2014-201S SAMPLE QUARTER: ❑Jul -Sept ❑Oct -Dec ®Jan -March ❑April -June COUNTY: Person PHONE NO. (336) 599 - 8343 ADD TO LISTSERVE? ❑YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C OPTIONAL INFO: Outfall No. Date Sample 1 collected (mm/dd/yr) Type of Wastewater z (VERMMD} , , pH (standard} Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH using method 1664A 5 (mg/L) Discharge Duration (minutes) Total Flow , (gallons/day} - - - 6-93,4 303,5 53 (15)6 - - 1 NO FLOW VE RM MD N/A No Qualifying Discharge observed this Period - 1 If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. 2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date:7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality l Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gather' g the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware_tha ere are signifi nt penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." /7XI (Signat a of ermittee) (Date) Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 FACILITY NAME: Chandler Concrete Company - Roxboro Pit. 607 PERSON COLLECTING SAMPLES: CERTIFIED LABORATORY:Pace Analytical Lab #633 LIMIT VIOLATIONS? YES ®NO ❑ Part A: Wastewater Monitorine Reauirements 0 Orig - State Copy -State 0 Copy - Plant 0 Copy - File SAMPLE COLLECTION YEAR: 2014-2015 SAMPLE QUARTER: ❑Jul -Sept ❑Oct -Dec ®Jan -March ❑April -June COUNTY: Person PHONE NO. (336) 599 - 8343 ADD TO LISTSERVE? ❑YES ®NO EMAIL: DISCHARGING TO CLASS: [_]SA []HQW ❑PNA ❑Trout ®Other: C OPTIONAL INFO: Outfall No. Date Sample 1 Collected (mm/dd/yr) Type of Wastewater (VE, RM, MD)2 pH (standard) Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH using method 1664A S mLM' Discharge Duration (minutes) Total Flow , {gallons/day( - - - 6-93'4 303s 53 (15)6 - - 1 NO FLOW VE RM MD N/A No Qualifying Discharge observed this Period - ' 4 1 If wastewater systems have not discharged in this quarter— report "No Flow" or "No Discharge" here. Please make sure to mark the sample q ti o T Yr.r Z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM , Cleanout (MD). Report more than one type if the waste -stream is commingled. p�4��H�S 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff G notifies you to continue monitoring. A pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ and the DWQ Regional Office may require an annual flow report on a case -by -case basis. �lr Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY INCLUDING ALL "NO FLOW" "NO DISCHARGE" WITHIN 30 DAYS OF RECEIPT OF SAMPLE OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUSTSIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gather' g the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware thaAAere are signifi�t penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 7 lJ (Signat a of ermittee) (Date) Permit Date:7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 PROCESS WASTEWATER -- Quarters Discharge Monitoring Report 0 Copy State y g g p Copy - State GENERAL PERMIT NO. NCG140000 0 Copy - Plant 0 Copy - File CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 SAMPLE COLLECTION YEAR: 2014-2015 FACILITY NAME: Chandler Concrete Company - Roxboro Pit. 607 SAMPLE QUARTER: ❑Jul -Sept ®Oct -Dec ❑Jan -March ®April -June PERSON COLLECTING SAMPLES: CERTIFIED LABORATORY:Pace Analytical Lab #633 LIMIT VIOLATIONS? YES ® NO ❑ Part A: Wastewater Monitoring Requirements COUNTY: Person ^c PHONE NO. (336) 599 - 8343 RECEIVED ADD TOLISTSERVE? [:]YES. ®NO EMAIL: FEB U $ ?CIS DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C CENTRAL FILES OPTIONAL INFO: DWR SECTION Outfall No. Date Sample i Collected (mm/dd/yr) Type of Wastewater 2 (VE, RM, MD} pH (standard) Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH usingDischarge method 1664A 6 SGT-HEM (mg/L) Duration (minutes) Total Flow 7 (gallons/day} - - - 6-93'4 303,5 53 (15)6 - - 1 NO FLOW VE RM MD N/A No Qualifying Discharge observed this Period - 1 If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. Z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. 4 pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 1SA NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919)807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather nd evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering he information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that t� are_significa penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permittee) 1--rd /S atO Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING FORM GENERAL PERMIT NO. NCG140000 T Orig-State 0 Copy - State 0 Copy - Plant CERTIFICATE OF COVERAGE NO. NCG14 0 0 9 1 SAMPLE COLLECTION YEAR:2014-2015 0 Copy- File FACILITY NAME: Chandler Concrete Co. - Roxboro Pit. 607 SAMPLING PERIOD: [A July -December ❑January -June PERSON COLLECTING SAMPLES: Michael Owen COUNTY person CERTIFIED LASORATORY:PaceAnalytical Lab #633 PHONE NO. (336) 599 - 8343 OPTIONAL INFO: ADD TO LISTSERVE? ❑YES ❑NO EMAIL: _ DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C Part A: Stormwater Monitoring Requirements Outfall No. Date Sample Collected mo dd r OR (/ /Y NO FLOW)' pH (standard Units] TSS (mg/L) Event Duration (minutes] Total a Rainfall (in} In Tier 2 Monthly Monitoring? (y/n) #i of Months in Tier 2 2 Sampling - - 6-9 100 , - - - - 2 NO FLOW N N/A rd 0 3 c:i; CENTRAl R SECT10 1 If "NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here. Please make sure to mark the sample period above. z If a value is in excess of the benchmark, or outside the benchmark range (for pH), you must implement the Tier 1 or Tier 2 responses in the General Permit. Tier 2 Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range. 3 TSS benchmark values are 100 mg/I, except when discharging to ORW, HQW, Trout, and PNA waters where they are 50 mg/I. ° For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge. .-D Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 1 of 2 Part B: Vehicle Maintenance Activity Monitoring Requirements for facilities using > 55 gal of new motor oil/month — averaged over a calendar year. Outfall No. Date Sample Collected (mo/dd/yr)1 PH (standard Units) TPH using method 1664A SGT-HEM (mg/L) Total Suspended Solids (mg/L) Event Duration (minutes) Total a Rainfall (in) New Motor Oil Usage (gal/month) In Tier 2 Monthly Monitoring? (Y/n) # of Months in Tier 2 2 Sampling 6-9 15 100 ' - - - - - - - - N / A - - - No vehicle maintenance performed at facility - - - HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES AT ANYONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES ❑ NO HAVE YOU CONTACTED THE REGION? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail Original and one coov of this DMR (including all "No Flow" & "No Discharge" reoorts) within 30 days of receiot of sample (or at end of monitoring period in case of "No Flow") to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly resgpnsible for Bath ring the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete am aware that th gnifi t ena ies for submitting false information, including the possibility of ffii es imprisonment for knowing violations." / A / / 3c) / /,S (Signature of Permittee) _ l/ (dte) Permit Date: 7/1/2011-60/30/2015 Last Revised 7/13/11 Page 2 of 2 Orig — State PROCESS WASTEWATER —Quarterly Discharge Monitoring Report 0 Copy — State GENERAL PERMIT NO. NCG140000 0 Copy — Plant 0 Copy - File CERTIFICATE OF COVERAGE NO. NCG14 0 0 9. 1 SAMPLE COLLECTION YEAR: 2014 FACILITY NAME: Chandler Concrete Com an Roxboro Pit. 607 SAMPLE QUARTER: ❑Jul -Sept ❑dct-Dec ❑Jan -March ®April -June PERSON COLLECTING SAMPLES: COUNTY: Person CERTIFIED LABORATORY:Pace Analytical Lab #633 PHONE NO. (336) 599 - 8343 ADD TO LISTSERVE? ❑YES ®NO EMAIL: LIMIT VIOLATIONS? YES ® NO ❑ DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C OPTIONAL INFO: Part A: Wastewater Monitoring Requirements Outfall No. Date Sample Collected' (mm/dd/yr) Type of Wastewater Z (VE, RM, MD] pH {standard} -Total Suspended Solids (mg/L) Settleable Solids (mL/L) TPH usingDischarge method 1664A 6 SGT-HEM (mg/L] Duration (minutes) Total Flow 7 {gallons/day} - - 6-93A 303,5 53 (15)6 - - 1 VE RM MD N/q 7 n ZRAL No Qualifying Discharge observed this Period - iDWQ/BQG ' If wastewater systems have not discharged in this quarter — report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. z Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 if an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. 7 Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ. If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY (INCLUDING ALL "NO FLOW", "NO DISCHARGE") WITHIN 30 DAYS OF RECEIPT OF SAMPLE (OR AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919)807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsi le for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. -I am aware that re re significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." /0 57 { ignature of Per ittee) (D te) Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 2 of 2 PROCESS WASTEWATER — Quarterly Discharge Monitoring Report GENERAL PERMIT No. NCG140000 CERTIFICATE OF COVERAGE NO. NCG14 0 0 91 FACILITY NAME: Chandler Concrete_ Company - Roxboro Pit. 607 PERSON COLLECTING SAMPLES: Michael Owen CERTIFIED LABORATORY:Pace Analytical Lab #633 LIMIT VIOLATIONS? YES ®NO ❑ Part A: Wastewater Monitoring Requirements Odg - State 0 Copy - State 0 Copy - F9ant 0 Copy - File SAMPLE COLLECTION YEAR: 2013 SAMPLE QUARTER: ❑Jul -Sept ❑Oct -Dec Dan -March ❑April -June COUNTY: Person PHONE NO. (336) 599 - 8343 ADD TO LISTSERVE? [-]YES ®NO EMAIL: DISCHARGING TO CLASS: ❑SA ❑HQW ❑PNA ❑Trout ®Other: C OPTIONAL INFO: Date Sample Type of Wastewater pH Total Suspended Settleable TPH usingDischarge method 1664A Total Flow outfail No. Collected' 2 (VE, RM, MD) (standard) Solids Solids SGT-HEM' Duration (gallons/day), (mm/dd/yr) (mg/L) (mL/L) (mg/L) minutes) - - - 6-93A 30"' 53 (15)6 - - 1 VE RM MD N/A 4'- fr^4 ALL ZU Y .. I V L. iL., YI I No Qualifying Discharge observed this Period - r FN T RAL F)LES owc )Bey ' If wastewater systems have not discharged in this quarter - report "No Flow" or "No Discharge" here. Please make sure to mark the sample quarter above. 2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (RM), Mixing Drum Cleanout (MD). Report more than one type if the waste -stream is commingled. 3 If an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RO staff notifies you to continue monitoring. ° pH limits are 6-9 S.U. for wastewater discharges to freshwaters, and 6.8-S.S S.U. for discharges to saltwaters. 5 TSS limits are 20 mg/L for wastewater discharges to HQW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications. 6 Process wastewater discharges shall only be monitored for TPH when commingled with stormwater discharges from VMA areas. TPH does not have a limit for wastewater, but instead Is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action. 7 Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7Q10 Flow as per 15A NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10 flow and report this information to DWQ, If the permittee cannot obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow report on a case -by -case basis. Permit Date: 7/1/2010-06/30/2015 Last Revised 07/13/11 Page 1 of 2 MAIL ORIGINAL AND ONE COPY OF THIS ANNUAL SUMMARY INCLUDING ALL "NO FLOW" "NO DISCHARGE" WITHIN 30 DAYS OF RECEIPT OF SAMPLE OR AT END OF MONITORING_ PERIOD IN CASE OF "NO FLOW") TO: Division of Water Quality n Attn: DWQCentral Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 (919) 807-6379 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED. "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the Information submitted. Based on my Inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Information, the Information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are s�� nt pen ies for submitting false Information, including the possibility of fines and imprisonment for knowing violations." / � re of Permittee) Permit Date:7/1/2010-06/30/2015 (D e) Last Revised 07/13/11 Page 2 of 2