HomeMy WebLinkAboutNCG020514_COMPLETE FILE - HISTORICAL_20170110STORMWATER DIVISION CODING SHEET
RESCISSIONS .
PERMIT NO.
Coaos I q
DOC TYPE
[I COMPLETE FILE -HISTORICAL
DATE OF
RESCISSION
❑
YYYYMMDD
ANNUAL SUMMARY DISCHARGE MONITORING
REPORT (DMR) —STORMWATER
SUBMIT TO CENTRAL OFFICE*
General Permit No. NCG020000
Calendar Year 2016
'Report ALL STORMWATER monitoring data on this form (include "No Flow"P'No Discharge" and Benchmark
Exceedances) from the previous calendar year to the DEQ by MARCH 1 of each year.
Certificate of Coverage No. N0002
Facility Name. Greenteknology Electronics Recycling Solutions, LLC
County: Mecklenburg
Phone Number: 7(_ 04 } 412-3343
Certified Laboratory Prism Laboratories, Inc
Lab # 402
Lab #
Total no. of SDOs monitored 1
Stormwater Discharge Outfall (SDO) No. 001 VMA Outfall? Yes ❑ No
Is this outfall currently in Tier 2 for any parameter? Yes ❑ No
Was this outfall ever in Tier 2 during the past year? Yes ❑ No ECEIVED
If this outfall was in Tier 2 last year, was monthly monitoring discontinued? !
Yes, enough consecutive samples below benchmarks to decrease frequency ❑ JAN 10 2011
Yes, received approval from DEMLR to reduce monitoring frequency ❑ CENTRAL FILES
No, turbidity benchmark exceedances did not require monthly monitoring ❑ DWR SECTION
Other ❑
Outfall No.
Total
Rainfall,
inches
TSS,
mgll
SS,
mlll
Turbidity,
NTU
Upstream
(U) Turbidity,
NTU
Downstream
(D) Turbidity,
NTU
Non -polar
O&G, mgll
(VMA)
New
Motor Oil
Usage
allmo.
Stormwater
Benchmarks
Indicate NO
FLOWif
a licable
circle
Benchmark
1 UU150
/�
4.1
Bencrclehmark
Benchmark
50/25/10
NIA
Water quality
Standard applies
NIA
Water Quality
Standard applies
1 5
average requires
>ra eaequi
TSS and Non -polar
O&G monitorin
Date Sample
Collected,
molddl r
MEOMMMMM
06/27/16
0.25
75
2.5
95.3
NIA
NIA
10/07/16
0.45
36
0.1
1 25.7
NIA
Permit Date 10/112015 — 9/30/2020
Last Revised 10-2-2015
NCDENR
Stormwater Discharge Outfall (SDO)
Qualitative Monitoring Report
For guidance on filling out this form, please visit: http:I/portal.ncdenr.org/web/Ir/npdes-stormwater/
Permit No.: N/C/ G/ 0/ 2/ 0/ 0/ 0/ 0 / or Certificate of Coverage No.: N/C/G/ 2 /0 / 0 / 5 / 1/ 4/
Facility Name: Greenteknology Electronics Recycling Solutions, LLC
County: Mecklenburg Phone No. 704-412-3343
Inspector
Sharon Bass
Date of Inspection: 10/7/16
Time of Inspection: 10:05
Total Event Precipitation (inches): 0.45
Was this a "Representative Storm Event" or "Measureable Storm Event" as defined by the permit?
(See information below.)
RI Yes ❑ No
Please verify whether Qualitative Monitoring must be performed during a "representative storm
event" or "measureable storm event" (requirements vary, depending on the permit).
Qualitative monitoring requirements vary. Most permits require qualitative monitoring to be
performed during a "representative storm event" or during a "measureable storm event." However,
some permits do not have this requirement. Please refer to these definitions, if applicable.
A "representative storm event" is a storm event that measures greater than 0.1 inches of rainfall
and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than
0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no
precipitation.
A "measurable storm event" is a storm event that results in an actual discharge from the
permitted site outfall. The previous measurable storm event must have been at least 72 hours
prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter
interval is representative for local storm events during the sampling period, and the permittee
obtains approval from the local DWQ Regional Office.
By this signature, I certify that this report is accurate and complete to the best of my knowledge:
�m
(Signature of Permittee or Designee)
Page 1 of 2
SWU-242, Last modified 7/31/2013
r,
V l
1. Outfall Description:
Outfali No. 001 Structure (pipe, ditch, etc.) paved lot channel
Receiving Stream: Stewart Creek
Describe the industrial activities that occur within the outfall drainage area: storage of electronic
components to be recycled_
Z. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint
(light, medium, dark) as descriptors: clear
3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil,
weak chlorine odor, etc.): none
4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is
clear and 5 is very cloudy:
1 M 3 4 5
5. Floating Solids: Choose the number which best describes the amount of floating solids in
the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids:
(1) 2 3 4 5
6. Suspended Solids: Choose the number which best describes the amount of suspended
solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy:
1 (2) 3 4 5
7. Is there any foam in the stormwater discharge? Yes (No-)
S. Is there an oil sheen in the stormwater discharge? Yes (N1
9. Is there evidence of erosion or deposition at the Yes (N1
outfall?
10. Other Obvious Indicators of Stormwater Pollution:
List and describe
Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition
may be indicative of pollutant exposure. These conditions warrant further investigation.
Page 2 of 2
5WU-242, Last modified 7/31/2013
Date:' 1017l16
Analyst: Sharon Bass
Facility Name: Greenleknology Electronics Recycling
Solutions, LLC
Permit 4: NCG2000001 Ccrt. of Coverage#: NCG200514
,"tleahle Solids
Reference Method:2540 F 20" Edition (include edition)
FaciMyllocation
Time
Sampled
Analysis
Time
Sample volume
anal next in mis
Start
time
45 minute
stir time
find
time
Result
ml/L
Comments
Greentek 5019 Iiovis
Rd., Suite G
Charlotte, NC 28208
WA5
12:10
1000
12:10
12:57
13:28
0.1
Very fine particles observed.
Particles tended to adhere to
sides of cone but were
dislodged and settled to
bottom.
Note: Samples must be gently agitated after 45 minutes and allowed to settle for an additional 15 min.
Field Personnel Notes
041041201 1