July 19, 2011
Mr. Loren Shumate -
Cardinai Quarries, LLC
1200 Claybank Road
West Jefferson, NC 28640
Subject: Compliance Evaluation Inspection
Cardinal Quarries, LLC
NPDES Permit # NCG020227
Ashe County
Dear Mr. Shumate
Dee Freeman
Secretary
On July 14, 2011 a Compliance Inspection was performed by George Smith, of this office. Mr. Loren Shumate
was present for the inspection. This facility holds a NTPDES General Permit NCG020000, which covers the
discharge of stormwater for establishments primarily engaged in Mining and Quarrying of Nonmetallic
Minerals.
Permit
This General Permit became effective January 1, 2010. Please read the permit and insure that you are compliant
with all terms and conditions.
Part III, Section A - Stormwater Pollution Prevention Plan (SPPP)
The SPPP is kept in a folder. There is a separate 3-ring binder that covers Employee Training.
All stormwater outfalls must be evaluated for the presence of non-stormwater discharges as shown in the permit
per Part 111, Section A 1 (e). This must be done annually.
Part III, Section B — Stormwater Analytical Monitoring
Analytical tests, such as, Settleable Solids, Total Suspended Solids, and Turbidity are performed quarterly at
Outfall 001 by using approved analytical methods by a certified lab/person. These tests are only required semi-
annually.
Rainfall is measured and documented in a separate log. Sampling must be performed during a representative
rainfall event.
North Carolina Division of Water Quality, Winston-Salem Regional Office
Location: 585 Waughtown St. Winston-Salem, North Carolina 27107 One
Phone: 336-771-50001 FAX: 336-771.46301 Customer Service:1-877-623-6748 NorthCarolina
Internet wwwricwaterquality,org Nattya1`y l �
An Equal Opportunity 1 Affirmative Action Employer L
CEI
July 19, 2011
Page 2 of 3
Part III, Section C — On -Site Vehicle Maintenance Monitoring
You must determine if the vehicle maintenance area uses more than 55 gal/month of new motor oil, when
averaged over a calendar year.
Analytical monitoring is performed quarterly at Outfall 001 for the following: pH and TSS.
The following semi-annual analytical monitoring was not performed at Outfall 001: Total Petroleum
Hydrocarbons (TPH). Please perform this test immediately as required per the permit.
These tests must be performed as shown in Table 4. On -site vehicle sampling may be relocated from Outfall
001 after the stream piping project is completed.
These tests may not be required if the new motor oil usage is 55 gal/month or less.
Part III, Section D - Qualitative Monitoring
The following discharge characteristics were performed at Outfall 001 as required per Table 6: Color, Odor,
Clarity, Floating Solids, Suspended Solids, Foam, and Oil Sheen.
The following three discharge characteristics were not performed at Outfall 001: (1) Deposition at or
immediately below the outfall; (2) Erosion at or immediately below the outfall; (3) Other obvious indicators of
stormwater pollution. Starting immediately, please add these three discharge characteristics in your qualitative
monitoring report.
Part III, Section E — Mine Dewatering & Process Wastewaters
Analytical monitoring is performed quarterly at Outfall 001 for the following: pH, Settleable Solids, TSS, and
Turbidity. This meets the permit requirement.
These tests are performed as shown in Table 7. Mine dewatcr sampling may be relocated from Outfall 001 after
the stream piping project is completed.
The process recycle pond had approximately 4-feet of freeboard. This meets the requirement of a minimum of
2-feet. After the stream piping project is completed this may meet the requirements for a closed -loop recycle
wastewater system.
Facility Site Review
The vehicle maintenance area contains various types of petroleum products in drums and storage tanks. They all
have secondary containment measures. This office encourages the facility to make sure the containment areas
are maintained.
There was a complaint received from the landowner at 2119 Claybank Creek. During the inspection there was
some residual sediment on the driveway at 2119 Claybank Road. Mr. Shumate indicated that a 3-inch rainfall
event caused the creek to rise. The pipe under Claybank Road was unable to carry the stormwater capacity.
f
t
m�
CEI
July 19, 2011
Page 3 of 3
There were no failures of the recycle or stormwater ponds. Increasing the capacity of the stormwater pond and
completion of the stream piping project should reduce the possibility of excess stormwater being delivered to
Claybank Road.
Effluent/Receiving Waters
The effluent to Claybank Creek, Class C Trout + waters of the State was clear at the time of the inspection.
There were not any adverse stream impacts noticed.
Actions Required
1. Please read your permit and make sure you are in compliance with the sampling requirements, new
motor oil usage, and adherence with the Tier actions that are required.
2. Please inform this office when you will start and complete the stream piping project.
3. Please inform this office when you will enlarge the stormwater pond and move the office and scale
house.
The above actions require a written response to this office within 15 days of receipt of this report.
During late October 2011 a compliance inspection will be scheduled so that we can determine the correct
location of the stormwater and process outfalls. Hopefully all the facility modifications and U.S. Army Corps of
Engineer permit requirements will be completed. In the meantime analytical and qualitative compliance will be
judged from the sampling performed at Outfall 001.
The compliance inspection is satisfactory pending a written response is sent to this office. If you have any
questions please contact George Smith or me at (336) 771-5000.
Sincerely,
W. Corey Basinger
Regional Supervisor
cc: WSRO Files
r,
Compliance Inspection Report
Permit: NCG020227 Effective: 01/01/10 Expiration: 12/31/14 Owner: Cardinal Quaries LLC
SOC: Effective: Expiration: Facility: Smithport Quarry
County: Ashe 1200 Claybank Rd
Region: Winston-Salem
West Jefferson NC 28694
Contact Person: Loren Shumate Title: Phone: 336-246-7312
Directions to Facility:
System Classifications:
Primary ORC: Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 07/1412011 Entry Time: 09:50 AM Exit Time: 11:15 AM
Primary Inspector: George S Smith Phone: 336-771-5000
Secondary inspector(s):
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Mining Activities Stormwater Discharge COC
Facility Status: ■ Compliant ❑ Not Compliant
Question Areas:
E Storm Water
(See attachment summary)
b YlY Lcs r, dr'errl
o - 76 = 776 3
L�tr��► Sh�►����
731Z
Page: 1
Permit: NCG020227 Owner- Facility: Cardinal Quaries LLC
Inspection Rate: 07/14/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
Page: 2
Permit: NCG020227 Owner -Facility: Cardinal4uaries LLC
Inspection Date: 07/14/2011 Inspection Type: Compliance Evaluation
Reason for Visit: Routine
Stormwater Pollution Prevention Plan
Yes
No
NA
NE
Does the site have a Stormwater Pollution Prevention Plan?
e
n
n
n
# Does the Plan include a General Location (USGS) map?
■
❑
n
n
# Does the Plan include a "Narrative Description of Practices'?
■
n
n
D
# Does the Plan include a detailed site map including outfall locations and drainage areas?
■
n
n
❑
# Does the Plan include a list of significant spills occurring during the past 3 years?
■
n
n
D
# Has the facility evaluated feasible alternatives to current practices?
■
❑
Q
❑
# Does the facility provide all necessary secondary containment?
■
CI
n
n
# Does the Plan include a BMP summary?
■
n
n
n
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
■
❑
11
0
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
■
n
n
Q
# Does the facility provide and document Employee Training?
■
n
n
D
# Does the Plan include a fist of Responsible Party(s)?
■
n
n
n
# Is the Plan reviewed and updated annually?
■
❑
n
0
# Does the Plan include a Stormwater Facility Inspection Program?
■
❑
n
D
Has the Stormwater Pollution Prevention Plan been implemented?
■
Q
n
n
Comment:
Qualitative Monitoring
Yes
No
NA
NE
Has the facility conducted its Qualitative Monitoring semi-annually?
Q
■
0
0
Comment: The last 3 characterisitics must be included in the monitoring. This is
mentioned in the report.
Analytica[ Monitoring
Yes
No
NA
NE
Has the facility conducted its Analytica! monitoring?
MOOD
# Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas?
D
■
D
D
Comment: Need to have new motor oil usage. Also, may need to perform Total
Petroluem Hydrocarbons.
Permit and Outfalls
Yes
No
NA
NE
# Is a copy of the Permit and the Certificate of Coverage available at the site?
0130
n
# Were all outfalls observed during the inspection?
■
n
n
D
# If the facility has representative outfall status, is it properly documented by the Division?
n
■
n
n
# Has the facility evaluated all illicit (non Stormwater) discharges?
D
n
D
■
Page: 3
Permit: NCG020227 Owner- Facility: Cardinal Quaries LLC
#je
Inspection Date: 07/14/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Comment:
Page: 4
October 29, 2009
Mr. Ceor S. SmithN.0ter Quality
585 Waughtown Street
Winston-Salem, North Carolina 27107
Re: Cardinal Quarries, LLC - Smethport Quarry
General Permit No. NCG020000
Dear Mr. Smith,
CARDINAL QUARRIES, LLC
P. O. BOX 540 • SALEM, VA 24153
TELEPHONE 540-380-5555
FAX 540-380-4365
N r "!Pot. Of EN4
NOV 0 2 20M
Winston-saie''
RCgion.11 off e
Please find enclosed the information requested for the above mentioned permit which include the
Discharge Monitor Reports for 2008 & 2009 and site topography map showing the sediment
control ponds.
Feel free to contact me if you need any additional information. I look forward to meeting you on
site Tuesday, November 10' at 10.00AM.
i cer y,
ony Landreth
Operations Coordinator
e
QUA
op
!
1r7J0-�j
'r s o� yay ^�P1 N.Q
f 5 1 .. 4 � � �� �
•i r
�i S � } �
_
� �
��
- � - � i
z � r �
� 1
REF #F-1
n DEISTER
ae'X24`
GRIZZLY
FEEDER
REF
#CR-1
KOL BE R£
o f
3546
i
JAW
CRUSHER
600 TPH)
AB
Cardinal Quarries, LLC
Smethport Quarry
#0500054
Process Ftow Schematic
SURGE .
C-6 (30' X 16G' 300 TPH) "
REF �
#F-2 REF #SCR-1
SYNTRON MISTER 7 X 20
FEEDER C-1B (42' X TRIPLE -DECK SCREEN
225' 1100 TPH)
C-2 (36' X 72' 600 TPH)1
C 640
STONE
All L4ERUSHPI 1�t
fGNE Coo
YCRUSHE
42' X
la4' 500 TPH}
04 (30` X 111' 690 TPH)
C-7 (36' X 152' 500 TPH)
25
TON
BIN
REF
L
REF
#CR-3
#F-4
SVEDALASYNTRON
H6000 FEEDER
CRUSHERY
REF #SCR-2
MISTER 8 X 20
TRIPLE -DECK
WET SCREEN
REF #SS-2
MGLANAHAN
54' SAND SCRE
C-9 36' X 1211
350TPH}
C-12 (30' X
100' 200TPH)
C-1a (24' X
100' 20OTPH) C-11
(24` X
100'
200TPH5
iii
SAND
A A
B'S/7614 57'S/
67'S