HomeMy WebLinkAboutNCG020045_COMPLETE FILE - HISTORICAL_20071029STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO.
oa D C)qs-
DOC TYPE
VHISTORICAL FILE
❑ MONITORING REPORTS
DOC DATE -
- ❑ OS UU' 1 1 U d-
YYYYMMDD
of \NArF9
O �
Mr. Brian North
Martin Marietta Materials, Inc.
P.O. Box 7446
Charlotte, NC 28241-7446
Dear Mr. North:
Michael F. Easley, Govet-rtbr
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
Coleen H. Sullins, Director
Division of Water Quality
October 29, 2007
Subject: NOTICE OF DEFICIENCY
Compliance Evaluation Inspection
NPDES Permit No, NCG020045
Arrowwood Facility
Mecklenburg County, North Carolina
Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection conducted at
the subject facility on September 10, 2007, by Ms. Polly Lespinasse of this Office.
It is requested that a written response be submitted to this Office by November 29, 2007, addressing the
deficiencies noted in the Inspection Summary, Qualitative Monitoring, and Permits and Outfalls
Sections of the report. In responding, please address your comments to the attention of Ms. Marcia Allocco.
The report should be self-explanatory, however, should you have any questions concerning this report, please
do not hesitate to contact Ms. Lespinasse or me at (704) 663-1699.
Sincerely,
_4 j �r-
Robert B. Krebs
Regional Supervisor
Surface Water Protection Section
Enclosure
cc: Shelton Sullivan, DWQ, NPS-ACO Unit
North Carolina Division of Water Quality 610 East Center Avenue, Suite 301
IntemeL h2o.enr.state.nc.us Mooresville, NC 28115
Phone (704)663.1699
Fax (704)663.6040
NorthCarolina
An Equal Opportunity/Affirmative Action Employer — 50% Recycled110% Post Consumer Paper
Compliance Inspection Report
Permit: NCG020045 Effective: 01/19/05 Expiration: 12/31/09 Owner: Martin Marietta Materials Inc
SOC: Effective: Expiration: Facility: Martin Marietta-Arrowwood
County: Mecklenburg 11325 Texland Blvd
Region: Mooresville
Charlotte NC 28217
Contact Person: Brian K North Title: Phone: 704-409-1475
Directions to Facility:
System Classifications:
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Certification. Phone:
Inspection Date: 09/1012007 Entry Time: 09:00 AM . Exit Time: 10:15 AM
Primary Inspector: Polly Lespinasse Phone:
Secondary Inspector(s):
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Mining Activities Stormwater Discharge COG
Facility Status: ❑ Compliant IN Not Compliant
Question Areas:
® Storm water
(See attachment summary)
Page: 1
Permit: NCG020045 Owner - Facility: Martin Marietta Materials Inc
Inspection Date: 09/10/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
Overall the facility appeared to be in general compliance. There were some minor issues associated with the storm water
pollution prevention plan. Qualitative monitoring has not been conducted at the facility. Discussed feasible alternatives
regarding providing secondary containment at fueling areas, providing containment for vehicle wash areas (or recycling
the washwater). Some housekeeping issues were observed during the facility inspection. The oil storage containment
area had both product and waste in it. There were some drums of petroleum being stored outside (not under cover and
not in containment). Petroleum contaminated soils were observed on the ground in the vehicle maintenance area.
Containment areas must be inspected and maintained. Petroleum contaminated soils must be excavated and properly
disposed of.
There was a land disturbance area that was not stabilized and a sediment basin had not been installed in the vicinity of
the discharge from this area. Appropriate erosion control measures must be installed and maintained.
An oil sheen was observed on the water surface in the mine pit. The water from this pit is pumped out into a settling cell
and reused, as was the process on the day of the inspection. However, when water is not required, the mine water is
pumped and discharged directly into a lake that then discharges to a stream. There are not treatment measures from the
discharge point to the stream (the lake that the water discharges to all provides attentuation for other properties located
around it. The source of oil in the pit must be determined and corrected.
Page: 2
Permit: NCG020045 Owner - Facility: Martin Marietta Materials Inc
inspection,Date: 0911012007 Inspection Type: Compliance Evaluation . ,
Reasorrfor Visit: Routine
Stormwater Pollution Prevention Plan
Yes
No
NA
NE
Does the site have a Stormwater Pollution Prevention Plan?
# Does the Plan include a General Location (USGS) map?
®
0
❑
❑
# Does the Plan include a "Narrative Description of Practices"?
®
0
0
0
# Does the Plan include a detailed site map including outfall locations and drainage areas?
■
❑
0
# Does the Plan include a list of significant spills occurring during the past 3 years?
# Has the facility evaluated feasible alternatives to current practices?
0
■
0
El
# Does the facility provide all necessary secondary containment?
■
0
0
0
# Does the Plan include a BMP summary?
■
❑
Cl
n
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
■
0
Cl
0
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
■
D
# Does the facility provide and document Employee Training?
■
n
n
n
# Does the Plan include a list of Responsible Party(s)?
0
■
n
0
# Is the Plan reviewed and updated annually?
■
n
n
n
# Does the Plan include a Stormwater Facility Inspection Program?
n
n
n
Has the Stormwater Pollution Prevention Plan been implemented?
■
❑
Q
n
Comment: An SWPPP is not required, but the facility has a document titled such.
Discussed feasible alternatives (i.e., providing secondary containment for fuel
dispensing areas, spill kits at fuel dispensing areas). The training log was not available
on site (kept in a different facility) and the training module did not include a specific
storm water section. The responsible parties list did not include the person that
conducts the routine facility inspections. Recommended adding an "plan update" page
as the plan should be updated annually (plan developed 06/07).
QuaWative Monitoring s
Yes
No
NA
NE
Has the facility conducted its Qualitative Monitoring semi-annually?
00013
Comment: Qualititative monitoring has not been conducted and documented for this
facility.
Analytical Monitoring
Yes
No
NA
NE
Has the facility conducted its Analytical monitoring?
■
❑
❑
0
# Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas?
■
❑
n
Comment: Facility has analyzed stormwater for all required parameters. None of the
parameters exceeded the cutoff concentration limits/benchmarks.
Permit and Outfalls
Yes
No
NA
NE
# Is a copy of the Permit and the Certificate of Coverage available at the site?
■
❑
❑
D
Page: 3
Permit: NCG020045 Owner - Facility: Martin Marietta Materials Inc
Inspection Date: 09I1012007 Inspection Type: Compliance Evaluation
# Were all outfalls observed during the inspection?
# If the facility has representative outfall status, is it properly documented by the Division?
# Has the facility evaluated all illicit (non stormwater) discharges?
Comment: The facility has requested representative outfall status for the facility.
According to facility representatives, a response was not received from DWQ. The
facility must provide documentation to DWQ to indicate that respresentative outfall
status was requested.
Reason for Visit: Routine
Page: 4