Loading...
HomeMy WebLinkAboutNC0032174_Compliance Evaluation Inspection_20191227 December 27, 2019 George H Schultz United World Mission PO Box 250 Union Mills, NC 28167-0250 SUBJECT: Compliance Inspection Report United World Mission NPDES WW Permit No. NC0032174 Rutherford County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the United World Mission on 12/16/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0032174. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact me at 828-296-4686 or via email at mikal.willmer@ncdenr.gov. Sincerely, Mikal Willmer, Environmental Specialist II Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS: Inspection Report EC: WQS-ARO Server, LF G:\WR\WQ\Rutherford\Wastewater\Minors\United World Mission 32174\Inspections\Dec. 16, 2019\20191227_NC0032174_CEI DocuSign Envelope ID: 9061B9B8-A6CB-4CAA-A1DA-31571732E51B EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0032174 19/12/16 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) United World Mission 6494 Hudlow Rd Union Mills NC 28167 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 10:00AM 19/12/16 18/10/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Donald Eugene Raisch/ORC/828-287-8996/ Other Facility Data 11:30AM 19/12/16 23/07/31 Name, Address of Responsible Official/Title/Phone and Fax Number George H Schultz,PO Box 250 Union Mills NC 281670250//828-287-8996/8282870580 Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self-Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Mikal Willmer DWR/Division of Water Quality/828-296-4686/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 9061B9B8-A6CB-4CAA-A1DA-31571732E51B 12/27/2019 12/27/2019 NPDES yr/mo/day 19/12/16 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Mikal Willmer, with the Asheville Regional Office, conducted a compliance evaluation inspection of the United World Mission WWTP on December 16, 2019. This inspection was conducted to determine whether the facility is being operated and maintained in compliance with NPDES Permit No. NC0032174. Don Raisch, ORC, was present and assisted in the inspection. Overall the facility is being operated and maintained in compliance. Below are items noted during the inspection. Septic/Filter/Pump Tanks: Solids are monitored and removed as needed. It was previously recommended United World Mission consider a septic tank heater to increase biological activity during colder months. This may aid in nitrification during the colder months. Sand Filter: Dosing alternates between zones of sand filter. Mr. Raisch routinely rakes and removes vegetation from the filter bed. Installation of a cover may help limit the introduction of vegetation, reduce maintenance and may help retain more consistent ambient conditions within the filter bed. The facility may also wish to pursue permanent recirculation to further aid in nitrification. Flow Monitoring: Mr. Raisch reports the reported flow may be an over estimation of actual daily flow. All flows are pumped through the facility and effluent is pumped to the discharge location. Due to low flows and effluent pump tank capacity, effluent is only discharged when sampling occurs. Staff may wish to install an inline meter to determine the actual flow into the facility for a more accurate daily flow. NC0032174 17 (Cont.) Page#2 DocuSign Envelope ID: 9061B9B8-A6CB-4CAA-A1DA-31571732E51B Permit:NC0032174 Inspection Date:12/16/2019 Owner - Facility: Inspection Type: United World Mission Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? System is comprised of septic tanks, filter tanks, pump tanks and a single-pass sand filter bed. Solids levels are checked periodically within tanks. Mr. Raisch, ORC, stated he checks ammonia levels with test strips to determine if treatment adjustments are needed. Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Comment: Sand Filters (Low rate)Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Is the sand filter effluent re-circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) This is a single-pass sand filter bed. A line has been installed to manually recirculate effluent when ammonia levels begin to rise. It is not designed to automatically recirculate a portion of the sand filter effluent. Comment: Disinfection - UV Yes No NA NE Page#3 DocuSign Envelope ID: 9061B9B8-A6CB-4CAA-A1DA-31571732E51B Permit:NC0032174 Inspection Date:12/16/2019 Owner - Facility: Inspection Type: United World Mission Compliance Evaluation Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? Are UV bulbs clean? Is UV intensity adequate? Is transmittance at or above designed level? Is there a backup system on site? Is effluent clear and free of solids? An inline UV system is installed with a manual wiper. Mr. Raisch reports the bulb is cleaned during daily checks. Spare bulbs and chlorine & dechlor tablets are kept within a building by the sand filter. The bulb are replaced if staff see a rise in fecal numbers. Effluent flow is restricted to 4000 gallons when pumped to allow adequate disinfection. Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ORC collects DO, pH and Temperature. All other grab samples are collected from the effluent pipe by Earth Environmental. Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Path to effluent pipe is clear and easily accessible.Comment: Page#4 DocuSign Envelope ID: 9061B9B8-A6CB-4CAA-A1DA-31571732E51B Certificate Of Completion Envelope Id: 9061B9B8A6CB4CAAA1DA31571732E51B Status: Completed Subject: Please DocuSign: 20191227_NC0032174_CEI.ltr.docx, 20191227_NC0032174_CEI.inspect.pdf Source Envelope: Document Pages: 5 Signatures: 3 Envelope Originator: Certificate Pages: 2 Initials: 0 Mikal Willmer AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-05:00) Eastern Time (US & Canada) 217 W. Jones Street Raleigh, NC 27699 Mikal.willmer@ncdenr.gov IP Address: 149.168.204.10 Record Tracking Status: Original Dec 27, 2019 | 08:53 Holder: Mikal Willmer Mikal.willmer@ncdenr.gov Location: DocuSign Signer Events Signature Timestamp Mikal Willmer mikal.willmer@ncdenr.gov Environmental Specialist North Carolina Department of Environmental Quality Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 149.168.204.10 Sent: Dec 27, 2019 | 08:55 Viewed: Dec 27, 2019 | 08:55 Signed: Dec 27, 2019 | 08:55 Electronic Record and Signature Disclosure: Not Offered via DocuSign Brett Laverty brett.laverty@ncdenr.gov Hydrogeologist II North Carolina Department of Environmental Quality Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 149.168.204.10 Sent: Dec 27, 2019 | 08:55 Viewed: Dec 27, 2019 | 08:55 Signed: Dec 27, 2019 | 08:57 Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted Dec 27, 2019 | 08:55 Certified Delivered Security Checked Dec 27, 2019 | 08:55 Signing Complete Security Checked Dec 27, 2019 | 08:57 Envelope Summary Events Status Timestamps Completed Security Checked Dec 27, 2019 | 08:57 Payment Events Status Timestamps