Loading...
HomeMy WebLinkAboutWQ0041283_Application (FTSE)_20191101"��` I r31Is �r� I I ��y •4„�� /G'l �I 1}�5tate of forth Carolina Department of Environmental Quality DWR ty Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTE_-I EXTENSION APPLICATION f3l�isloi7 of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: 0 00 lw ltobccnmpirtidha DWRI All items must he completed or the application will be returned p I. APPLICANT INFORMATION: 1. Applicant's name: Old North State Water Company. LLC (company, municipality. VIOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Pri%-ately-0«ncd Public Utility ❑ Federal ❑ State. County ❑ Municipal ❑ Other 3. Signature authority's name: Lee Bowman per 15A NCAC 02T .0106 h Title: Director of Protect and Corporate Development 4. Applicant's mailing address: 4700 Homewood Court. Suite 108 7J City: Raleigh State: NC Zip: 27609-� 5. Applicant's contact information: —y Phone number: (252) 236-5710 Email Address: Iboumanoenvirolinkinc.com c � s II. PROJECT INFORMATION: 1. Project name: Granite Mill Blvd. Force Main Fxtension 2. Application: Project status: ® Proposed (Nc%% Permit) ❑ Existing Permit. -Project �z n If a modification, provide the existing permit number: «'QOO_ and issued date - If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Chatham 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.8158 Longitude: -79.1 130 5. Parcel ID(ifapplicable): 91380 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: Gareth Avant License Number: 036348 Finn: McKim & Creed, Inc. Mailing address: 1730 Varsity Drive, Suite 500 City. Raleigh State: [C Zip: 27606 Phone number: (919) 233-RO9I Email Address: gavant(u mckimcreed coin IV. WASTEWATER TREATMENT FACI LITN'(WWTF) INFORMATION: 1. Facility Name: Briar Chapel Utilities Wastewater Treatment Facility Phases A and B Owner Name: Old North State Water Company. LLC V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WN' TF): I. Permit Number(s): WQQO37256 Nlodificaton iBriar Chapel Phase 1 1) System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Old North State Water Company, LLC Permit Number: W00028551 FORM: FTA 04-16 Page[ of 5 Vl. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ®Yes [:]No ❑N. A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORNI_DEV) been attached? ❑ Yes ®No ❑MA 3. If the Applicant is a Home-Proaerty Owners' Association, has an Operational Agreement (FORNI: HOA) been attached? ❑ Yes ®No ❑N 'A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation?service ❑ Hotel andior Motels ❑ School / preschool / day care ❑ Medical dental / veterinary facilities ❑ Swimming Pool +Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool+Filter Backwash ❑ Businesses / offices I factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: P-o Domestic,;Commercial % Commercial °lo Industrial (See 15A NCAC 02T .0103(,20-)) 1Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)fl? ❑ Yes ® No If vesprovide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.01140 Daily Design Flow °'' No. of Units Flow gal;' GPD gal! GPD gal;' GPD gal.' GPD gal' GPD gal' GPD 7olal GPD a See 15A NCAC 02T .0114 b d . e i and e 2 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or cast of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per I5A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .01 la) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ® Pump Station or Gravity Sewer where flow will be permitted in subsequent pennits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VI1. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material Section II &III of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable)-02T .0305 & MDC(Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: N_'A millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): —N.-'A gallons per minute at Ni'A feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 4 756 DIP 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(I)(B); 1- Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day i Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - I5A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305 & i 15A NCAC 02T.0305(f) contains minimum separations that shall be nrovided for sewers stems: ® Yes [:]No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains vertical -water over sewer including in benched trenches) 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from nonnal high water (or tide elevation) and wetlands see item IX.2) 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools I0 feet Final earth grade (vertical) 36 inches i 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved. **Stream classifications can be identified using the Division's NC Surfke Water 'Iasi i s t If noncompliance with 02T.0305(fl or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands'? (50 feet of separation) ® Yes [:]No :- Seethe Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per I5�AC 02B .0200? ® Yes [-]No Y This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No Wetiand-related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters Information can be obtained from the 401 & Buffer Permittini Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permitsicertifications)? ® Yes [:]No Per 15A_NCAC 02T.0„105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No .- If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(2)(5) or the permitee's individual System -Wide Collection permit. FORM. FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteriai for the Permitting of Pumn Stations anal Force Mains (latest version). and the Gravity •wer Minimum Design Criteria (latest version) as applicabic? ® Yes ❑ No If No, complete and submit the Vanance/Alternative Design Request application (VADC 10-14) and supporting document~ for review, AuRroval of the request is required prior to submittal of the Fast Track A lication and su ortin documents. 2. Professional Engineer's Ccrtilication: Gareth Avant (Professional Engineer's name froin Application Item Ill.1.) attcst that this application for has been reviewed by me and is aa:curatc, complete and consistent with the information supplied in the plans, specifications, engineering oieulntions, and ail other supporting documentation to the best of my knowledge. ( further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S10,000, as well as civil penalties up to $25.000 per violation. �ltltira�1�, North Carolina Professionalfessivnal Engineer's seal, signature, and date: iafi//' ��```��H "'offS. - 036 a.7 .. A. L,. ���rrrlraanuttrtit��`s Applicant's Certification per 15A NCAC 02T .0106(b): 1, "toe- 6 0W M J8 K A L-Aol' [ attest that this application for (Signature Authority's name & title from Application Item 1..) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated_ I also understand that if all required pans of this application package are not completed and that if al, requited supporting information and attachments are not included, this application package will be returned to me as incomplete_ NOTE — In accordance with General Statutes JL43-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature Date: FORM: 1TA 04-16 Page 5 of 4:��Mq<IM&CREED TO: Division of Water Resources Raleigh Regional Office 3800 Barrett Drive Raleigh, N.C. 27609 ATr hMON Mr. Danny Smith LETTER OF TRANSMITTAL DATE. October 24, 2019 PROJECr NO- 2735-0260 TASK No: REIMB RE Briar Chapel — Granite Mill Force Main Extension TRANSMITTAL NO.. PAGE 1 OF 1 WE ARE SENDING: ❑ Originals ❑ Prints ❑ Shop Drawings ❑ Samples ❑ Specifications ❑ CalcuIations ® Other - Fee Quantity Drawing No. Rev Description Status 2 EA Fast Track Application for Gravity Sewers, Pump Stations and G Force Mains 2 EA Project Narrative & USGS Map C • Including Certificate of Public Convenience and Necessity & Franchise Documentation 1 EA I Permit Application Fee ($480.00) C Issue Status Code: Remarks A. Preliminary B. Fabrication Only C. For Information D. Bid E. Construction F. For Review & Comments G. For Approval H. See Action Status Code: 1. No Exceptions Taken 2. Make Corrections Noted 3. Other 4. Amend & Resubmit 5. Rejected -See Remarks VC Dept of Environmental Q01ty NLIV -1 209 1730 Varsity Drive, Suite 500, RaleiA. 9 Mv&i.} Cc: File McKIM & CREED, INC. Signed Chris Seamster, RLA Project Manager FAST TRACK SEWER APPLICATION NARRATIVE Briar Chapel Development Granite Mill Blvd. Force Main Chatham County, North Carolina October 15, 2019 Prepared for: BRIARS CHAPEL'm Newland on+tmmmu NNP Briar Chapel, LLC 1342 Briar Chapel Parkway Chapel Hill, North Carolina 27516 Prepared By: *`*�*A MCICM&CREED 1730 Varsity Drive, Suite 500 Raleigh, North Carolina 27606 Phone: (919) 233.8091 Fax: (919) 233.8031 M&C Project No. 02735-0260 z d o a Q{ C p e`� �pFESSI 036348 - c�'•/O •/5-���'�: BRIAR CHAPEL DEVELOPMENT Granite Mill Blvd. Force Main October 15, 2014 PROJECT NARRATIVE The purpose of the project is to construct a force main along Granite Mill Boulevard in the Briar Chapel development. This force main is a continuation of a force main and pump station (designed by others) that ends at the intersection of Andrews Store Road and Granite Mill Boulevard and serves the proposed Chatham County elementary school site. The flow allocation through the force main will be permitted by others, so this section is being approved for a flow of 0 GPD. Summary of Sewer Lines to be permitted: • 756 LF of 4-inch DIP force main The sewage and wastewater collected by this system will be treated in the on -site wastewater treatment facility: WWTP Facility Name: Briar Chapel Utilities, LLC WWTP Facility Permit #WQ0028552 MAPS MAPS gW B CHEEK Rfl �590 o o ` AOLHS L4NDINGJRD 15 C Mountdj OAK �5 CD ca 0 �" s l9DN RD VICKERS RD rr"NAEa o LA A08 ANDREWS STARE- RD 501 ' ' r FOSTER LNG CRFEKW,O0 DO CERTIFICATE OF PUBLIC CONVENIENCE AND NECESSITY STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH APPENDIX A DOCKET NO. W-1300, SUB 9 BEFORE THE NORTH CAROLINA UTILITIES COMMISSION OLD NORTH STATE WATER COMPANY LLC is granted this CERTIFICATE OF PUBLIC CONVENIENCE AND NECESSITY to provide sewer utility service in BRIAR CHAPEL SUBDIVISION SERVICE AREA (including HERNDON WOODS SUBDIVISION) Chatham County, North Carolina subject to any orders, rules, regulations, and conditions nor or hereafter lawfully made by the North Carolina Utilities Commission ISSUED BY ORDER OF THE COMMISSION. This the 20th day of April~, 2016. NORTH CAROLINA UTILITIES COMMISSION 46L � Xfioun\* Gail L. Mount, Chief Clerk FRANCHISE DOCUMENT STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH DOCKET NO. W-1300, SUB 9 DOCKET NO. W-1230, SUB 1 BEFORE THE NORTH CAROLINA UTILITIES COMMISSION In the Matter of Application by Old North State Water Company, ) LLC, and Briar Chapel Utilities, LLC, for Authority to ) ORDER ALLOWING Transfer Sewer Utility Franchise in Briar Chapel ) RECOMMENDED Subdivision in Chatham County, North Carolina, to ) ORDER TO BECOME Old North State Water Company, LLC, and for ) EFFECTIVE AND FINAL Approval of Rates ) BY THE COMMISSION; On April 20, 2015, Hearing Examiner Ronald D. Brown issued in the above -captioned docket a Recommended Order Approving Transfer, Granting Franchise, Approving Rates, and Requiring Customer Notice. The parties have jointly requested that the Commission adopt the Recommended Order as a Final Order. Based upon the foregoing, the Commission is of the opinion that the request that the Recommended Order be adopted as the Final Order should be granted. IT IS, THEREFORE, ORDERED that the Recommended Order entered in this docket on April 20, 2015, is hereby adopted as the Final Order of the Commission. ISSUED BY ORDER OF THE COMMISSION. This the 20th day of April , 2015. NORTH CAROLINA UTILITIES COMMISSION sail, I.CYloum* Gail L. Mount, Chief Clerk Commissioners Susan W. Rabon and ToNola D. Brown -Bland did not participate. STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH APPENDIX A DOCKET NO. W-1300, SUB 9 BEFORE THE NORTH CAROLINA UTILITIES COMMISSION OLD NORTH STATE WATER COMPANY LLC is granted this CERTIFICATE OF PUBLIC CONVENIENCE AND NECESSITY to provide sewer utility service in BRIAR CHAPEL SUBDIVISION SERVICE AREA (including HERNDON WOODS SUBDIVISION) Chatham County, North Carolina subject to any orders, rules, regulations, and conditions nor or hereafter lawfully made by the North Carolina Utilities Commission ISSUED BY ORDER OF THE COMMISSION. This the loth day of April , 2015. NORTH CAROLINA UTILITIES COMMISSION A6L � .Mbwv\* Gail L. Mount, Chief Clerk State of North Carolina Department of Environmental Quality DWR Division of Water Resources Divislon of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Old North State Water Company, LLC Project Name for which flow is being requested: Granite Mill Blvd. Force Main Xfoi a than one FTSE mqn he required for a single project ij'the air ner c f the IVIVTP t v not responsihle fir all pinup stations along the route oj'the proposed %raste►vater flow, I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Briar Chapel Utilities Wastewater Facility Phases A and B ;V b. WWTP Facility Permit #: WQ0028552 All flows are in MGD is o c. WWTP facility's permitted flow 0.330 91 -CC IV d. Estimated obligated flow not yet tributary to the WWTP 0.122 ao ! e. WWTP facility's actual avg. flow 0.214 a N, f. Total flow for this specific request 0.000 g. Total actual and obligated flows to the facility 0.336 , h. Percent of permitted flow used 101.8010 � Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** Area D 0.417 0.112 0.026 0.002 0.028 0.084 29{ 0 gpm) Area D 0.518 0.165 0.042 0.002 0.044 0.121 (360 gpm) * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Briar Chapel Subdivision Phases A & B Downstream Permit Number: WQ0029867 Iz Page I of 6 FTSE 04-16 Ili. Certification Statement: I Lee Bowman (Director of certify to the best of my knowledge that the addition of _Corporate Development) the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and I1 plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. signing la3V9 Date Page 2 of 6 USE 04-16 Deck, Erin M From: Gareth Avant <GAvant@mckimcreed.com> Sent: Wednesday, December 18, 2019 4:56 PM To: Deck, Erin M; Ibowman@envirolinkinc.com Subject: [External] RE: Granite Mill Blvd. Force Main Extension Fast Track Sewer Extension Attachments: 01 2019.12.18.Phase 14.FTA 04-16.REVISED.pdf; 04 FT Sewer App 02.Phase 14 - Narrative.REVISED.pdf • Ememal email. Do not click links qr open attachments unless you verify. Send all suspicious email as an attaahmentr s a M 2m o Erin, Responses to your questions are below. I have also attached the updated sheets of the original documents. Please let me know if you have questions. Thank you! -Gareth From: Deck, Erin M <erin.deck@ncdenr.gov> Sent: Monday, December 16, 201912:29 PM To: Ibowman@envirolinkinc.com; Gareth Avant <GAvant@mckimcreed.com> Subject: Granite Mill Blvd. Force Main Extension Fast Track Sewer Extension Good Afternoon, We are in the process of reviewing the subject application and require additional information. • Per the narrative and section VI.8. no flow is being permitted with the current application. However, Section V1.4,5, and 7 all have flow allocated for the project. Please revise as appropriate. I have adjusted Page 2 of the Fast Track Application to be consistent with a flow allocation of 0. I have left sections 4, 5 and 7 blank to reflect this. • The narrative states that 754 If of 4-in force main is requested, however VI11.5. is requesting 756 If of force main. Please revise as appropriate. I have corrected the narrative to show the correct length of 756 If. Once this information is received, and the applicant agrees with the changes, we can move forward with drafting the permit. Thank you. Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office: 919-791-4258 Ic.- "Nothing Compares Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Disclaimer This e-mail and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this e-mail in error please notify the system manager. Please note that any views or opinions presented In this e-mail are solely those of the author and do not necessarily represent those of the company. Finally, the recipient should check this e-mail and any attachments for the presence of viruses, The company accepts no liability for any damage caused by any virus transmitted by this e-mail.