December 20, 2019
Lisa Triplett
City of Lenoir
PO Box 958
Lenoir, NC 28645-0958
SUBJECT: Compliance Inspection Report
Gunpowder Creek WWTP
NPDES WW Permit No. NCO023736
Caldwell County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Gunpowder Creek
WWTP on 12/18/2019. This inspection was conducted to verify that the facility is operating in
compliance with the conditions and limitations specified in NPDES WW Permit No. NC0023736. The
findings and comments noted during this inspection are provided in the enclosed copy of the inspection
report entitled "Compliance Inspection Report".
There were no significant issues or findings noted during the inspection and therefore, a response to this
inspection report is not required.
If you should have any questions, please do not hesitate to contact me with the Water
Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500 or via email at
tim.heim@ncdenr.gov.
Sincerely,
[DocuSigned by:
l�t,iw>
082111105AICA418_.
Tim Heim, P.E., Environmental Engineer
Water Quality Regional Operations Section
Asheville Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS
Ec:
WQS-ARO Server
LF
G:\WR\WQ\Caldwell\Wastewater\Municipal\Gunpowder Creek 23736\Inspections\2019 CEI\20191220_NC0023736_CEI.Docx
North CarotnsDepart rnentafEnvironmentalQvali[y I OiAsionofWater Resources
.shevdle Regonal Office 1 2090 V.S. 70 ftg ay I Sw nanos. North Carolnla 23773
nb.«..c.« 32S-96A500
DocuSign Envelope ID: 4227725B-54ED-46FA-BE03-9ADE9CA8C36E
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN I 2 IF I 3 I NC0023736 111 12 I 19/12/18 I17 18 I S J 19 L G] 201 I
211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
671
70 I I 71 I I 72 I r I 73 I I 174 751 I I I I I I I80
u I� I I i
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES oermit Number)
10:OOAM 19/12/18
14/07/01
Gunpowder Creek WWTP
450 Pine Mtn Rd
Exit Time/Date
Permit Expiration Date
Hudson NC 28638
02:OOPM 19/12/18
19/03/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Elisa Robbins Triplett/ORC/828-757-2198/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Monte L Wall,PO Box 958 Lenoir NC 286450958//828-757-2198/
Yes
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program 0 Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
o... Sig-d by: 12 z o 2 019
Timothy H Heim RumDWR/ARO WQ/828-296-4665/E�-6fI
Mika) Willmer DWR/Division of Water Quality/828-296-4686/
82e„o5A8CA4,8_
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
Cosigoea bv:
po���� 12/20/2019
]E61]A38285848C..
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
DocuSign Envelope ID: 4227725B-54ED-46FA-BE03-9ADE9CA8C36E
NPDES yr/mo/day Inspection Type (Cont.)
NCO023736 I11 12, 19/12/18 117 18 JCJ
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Tim Heim and Mikal Willmer of the Asheville Regional Office performed a routine Compliance
Evaluation Inspection of the facility on December 18, 2019. Lisa Triplett and Donnie Hawkins (City of
Lenoir) were present and assisted with the inspection. The facility appeared well maintained and
operated at the time of the inspection.
The following items were noted during the inspection:
The facility may wish to evaluate the use of liquid hypochlorite as an option during future plant
upgrades. Elimination of the chlorine gas cylinders may reduce operator risk and EPA Tier 2
Notification requirements
Page#
DocuSign Envelope ID: 4227725B-54ED-46FA-BE03-9ADE9CA8C36E
Permit: NCO023736 Owner - Facility: Gunpowder Creek WWTP
Inspection Date: 12/18/2019 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: pH, DO, Temp.
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
0
❑
❑
❑
application?
Is the facility as described in the permit?
0
❑
❑
❑
# Are there any special conditions for the permit?
❑
0
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the inspector granted access to all areas for inspection?
0
❑
❑
❑
Comment: The facility appeared well maintained at the time of the inspection.
Bar Screens
Yes No NA NE
Type of bar screen
a.Manual
❑
b.Mechanical
Are the bars adequately screening debris?
0
❑
❑
❑
Is the screen free of excessive debris?
0
❑
❑
❑
Is disposal of screening in compliance?
0
❑
❑
❑
Is the unit in good condition?
0
❑
❑
❑
Comment:
Grit Removal
Yes No NA NE
Type of grit removal
a.Manual
❑
b.Mechanical
Is the grit free of excessive organic matter?
❑
❑
❑
Is the grit free of excessive odor?
0
❑
❑
❑
# Is disposal of grit in compliance?
0
❑
❑
❑
Comment:
Page# 3
DocuSign Envelope ID: 4227725B-54ED-46FA-BE03-9ADE9CA8C36E
Permit: NCO023736
Owner - Facility: Gunpowder Creek WWTP
Inspection Date: 12/18/2019
Inspection Type: Compliance Evaluation
Sequencing Batch Reactors
Yes No NA NE
Type of operation:
Simplex, Multiple
Is the reactor effluent free of solids?
❑
❑
❑
Does minimum fill time correspond to the peak hour flow rate of the facility? ❑
❑
❑
Is aeration and mixing cycled on and off during fill?
❑
❑
❑
The operator understands and can explain the process?
0 ❑
❑
❑
Comment: The facility currently operates 3 SBR trains in
parallel. Two of the trains include a small and
medium reactor vessel operated concurrently,
and one train includes a single large reactor
vessel.
Disinfection -Gas
Are cylinders secured adequately?
Are cylinders protected from direct sunlight?
Is there adequate reserve supply of disinfectant?
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de -chlorination?
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)?
If yes, then is there a Risk Management Plan on site?
If yes, then what is the EPA twelve digit ID Number? (1000- - )
If yes, then when was the RMP last updated?
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ ■
■ ❑ ❑ ❑
❑ ❑ ❑ ■
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The facility may wish to evaluate the use of liquid hypochlorite as an option during future
plant upgrades. Elimination of the chlorine gas cylinders may reduce operator risk and EPA
Tier 2 Notification requirements.
De -chlorination
Type of system ?
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de -chlorination substance stored away from chlorine containers?
Comment:
Are the tablets the proper size and type?
Are tablet de -chlorinators operational?
Number of tubes in use?
Comment:
Yes No NA NE
Gas
■
❑
❑
❑
■
❑
❑
❑
■
❑
❑
❑
❑
❑
■
❑
❑
❑
■
❑
Page# 4
DocuSign Envelope ID: 4227725B-54ED-46FA-BE03-9ADE9CA8C36E
Permit: NC0023736
Inspection Date: 12/18/2019
Owner - Facility: Gunpowder Creek WWTP
Inspection Type: Compliance Evaluation
Standby Power
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
Is the generator fuel level monitored?
Comment:
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Yes No NA NE
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
■
❑
❑
❑
❑
❑
❑
❑
❑
❑
Yes No NA NE
■
❑
❑
❑
■
❑
❑
❑
❑
❑
■
❑
Page# 5