Loading...
HomeMy WebLinkAboutWQ0041076_Application (FTSE)_20191219Central Files. APS _ SWP _ 11/22/2019 Permit Number WQ0041076 Permit Tracking Slip Program Category Status Project Type Non -discharge In review Major modification Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions B Individual Primary Reviewer Permit Contact Affiliation dean.hunkele Coastal SWRuIe Permitted Flow 28,019 Facility Facility Name Major/Minor Region NC Shallotte Smith Commercial Public Pump Stations Minor Wilmington Location Address County Brunswick Facility Contact Affiliation Owner Owner Name Owner Type Town of Shallotte Government - Municipal Owner Affiliation Walter Eccard PO Box 2287 Dates/Events Shallotte NC 28459228 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 9/4/2019 11/22/2019 _ _ I LETTER OF TRANSMITTAL Via: _Hand Delivery U.S. Mail Fed Ex, UPS, Etc. Other DATE: TO: ADDRESS: 11/20/19 NC DEQ 127 Cardinal Drive Extension, Wilmington, NC 28405 ATTN: Dean Hunkele RE: NC Shallotte Smith LLC — Permit NO. WQ0041076 WE ARE SENDING YOU _Attached Prints Copy of Letter Under separate cover via _ _ Plans Other following items: Specifications COPIES I DATE I NO. DESCRIPTION 1 11-20-19 11 Revised Sewer Plan, Application and Modification Fee Check THESE ARE TRANSMITTED as checked below: For Approval —Approved as submitted For your use _ Approved as noted _ —As requested _ Returned for corrections For review and comment Other REMARKS: COPY N U V 2 2: 019 watrlr final �' ;eoonal Opetaiions Section wilmington Regional Office Resubmit copies for approval Submit copies for distribution Return corrected prints Arnold Consulting Engineering Services, Inc. P.O. Box 1338 1136 South Park Drive Bowling Green, KY 42101 Suite 201 Phone (270)780-9445 Bowling Green, KY 42103 Fax(270)780-9873 DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Town of Shallotte (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: Walter Eccard per 15A NCAC 02T .0I06(b) Title: Mayor 4. Applicant's mailing address: P.O. Box 2287 City: Shallotte State: NC Zip: 28459-2287 5. Applicant's contact information: Phone number: (910) 754-4032 Email Address: rwaringno townofshallotte.ore II=WM11111111111►f IM13RN001)0 ❑ Privately -Owned Public Utility ❑ Other 1. Project name: NC Shallotte Smith Commercial Public Pump Stations & Gravity Sewer 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: W00041076 and issued date: September 4, 2019 If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Brunswick 4. Approximate Coordinates (Decimal Degrees): Latitude: 33.98 1° Longitude:-78.377' 5. Parcel ID (if applicable): 1820002201, 18200022, 18200020, 1820002204, 1820002202, 1820002203, 18200023, 18200024, 182000191,1820002504 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Jeffery A. Arnold License Number: 042686 Firm: Arnold Consulting En ing eering Services, Inc. Mailing address: P.O. Box 1338 City: Bowling Green Phone number: (270) 780-9445 State: KY Zip: 42102 Email Address: bzackerv@a-ces.com IV. WASTEWATER TREATMENT FACILITY (W WTF) INFORMATION: 1. Facility Name: Shallotte W WTP Permit Number: W00000798 Owner Name: Brunswick County V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than W WTF): 1. Permit Number(s): WQEPA7234 Downstream (Receiving) Sewer Size: 6 inch System Wide Collection System Penn it Number(s) (if applicable): WQCS Owner Name(s): Town of Shallotte FORM: FTA 04-16 Page] of 5 VI. . GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes []No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ® Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ® Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : % Domestic/Commercial 100 % Commercial _ % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ❑ No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(t)) Daily Design Flow o,n No. of Units Flow gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 02T .0114(b), (d),(e)(H and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: _ GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: ETA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 1,863 SDR 35 ➢ Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Puma Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: 0Longitude: - ° 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): _ gallons per minute at _ feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & (g) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ❑ Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpaee ➢ If noncompliance with 02T.0305( or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ❑ No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Pennittinp Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ❑ Yes ❑ No Per 15A NCAC 02T.0 I 05(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ❑ No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for file Permitting of Pmnp Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Tract( Anulication an([ sapporting documents 2. Professional Engineer's Certification: ON,- rt'l cl name front Application Item 111.1.) that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of nay knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast= rrack Permitting of Puntp Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials tinder my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143.215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: SEAL 042,66 ; S Ec� '•.F F, �' O 3. Applicant's Certification per 15A NCAC 02T .0106(b): attest that this application for name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater front this non - discharge system to surface waters or the land will result in an inuuediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this pertnit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: l/v r'—q=�-L 11 Date: (1, M / I 4 FORM: FTA 04-16 Page 5 of 5 Arnold Consulting Engineering Services, Inc. P.O. Box 1338 1136 South Park Drive, Suite 201 Phone (270)780-9445 Bowling Green, KY 42101 Bowling Green, KY 42103 Fax (270)780-9873 November 20, 2019 NC DEQ Attn: Dean Hunkele 127 Cardinal Drive Extension Wilmington, INC 28405 RE: NC Shallotte Smith LLC — Permit No. WQ0041076 Mr. Hunkele: The purpose of the attached revision request is amend the current permit to include the gravity sewer lines as shown on the attached plans. The Town of Shallotte will now own and operate the gravity sewer lines along with the already permitted Commercial Pump Station. In conjunction with this revision, the permit which previously contained the gravity sewer lines (Permit No. WQ0041077) as private will now be void. T nk you, Brandy Zack P. Arnold Consulting Engineering Services, Inc.