HomeMy WebLinkAboutSW4190902_Supplement-EZ Form_20191217VV■ ■ ��■1■V■� ■—`fL V\/V1-1\ ■ r\vim
FORMS LOADCD
PROJECT INFORMATION
1
Project Name
Circle K R&R 2723188
2
Project Area ac
1.26
3
Coastal Wetland Area ac
0
4
Surface Water Area ac
0
5
Is this project High or Low Density?
Hi h
6
1 Does this project use an off -site SCM?
No
COMPLIANCE WITH 02H .1003(4)
7
Width of vegetated setbacks provided feet
0
8
Will the vegetated setback remain vegetated?
No
9
Is BUA other that as listed in .1 0034. c-d out of the setback?
No
10
Is streambank stabilization proposed on this project?
No
NUMBER AND TYPE OF SCMs:
11
Infiltration System
0
12
Bioretention Cell
0
13
Wet Pond
0
14
Stormwater Wetland
0
15
Permeable Pavement
0
16
ISand Filter
0
17
Rainwater Harvesting RWH
0
18
Green Roof
0
19
Level Spreader -Filter Stri(IS-FS
0
20
Disconnected Impervious Surface (DIS)
0
21
Treatment Swale
0
22
Dry Pond
0
23
StormFilter
0
24
Silva Cell
0
25
Bayfilter
1
26
Filterra
0
FORMS LOADED
DESIGNER CERTIFICATION
27
Name and Title:
Rick Baker
28
_
Organization:
Timmons Group
29
Street address:
5410 Trini Rd Ste 102
30
Ci , State, Zip:
Phone numbers :
Email:
Raleigh NC 27607
31
919-866-4939
32
hck.baker@timmons.com
Cemlfl cation ySWtoment
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or
supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and
that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent
with the information provided here.
.,j11411f1111////.
CA R p�I•,,,!
SEAL
022530
ANC! N
_,Soft ///Il1 ;11%1111
C�
105
Signature of Designer
Date
DRAINAGE AREAS
1 Is this a high density pro ect? Yes
2 If so number of draina a areas/SCMs 1
Is all/part of this project subject to previous rule
3 versions? No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1
4
Type of SCM
Bayfliter
5
Total BUA in project (sq ft
38302 sf
9320 sf
6permitting)
New BUA on subdivided lots (subject to
s ft
7
New BUA outside of subdivided lots (subject to
permitting) s
3547 sf
5194 sf
8
1 Offsite - total area (sq ft
9 Offsite BUA (sq ft
10 Breakdown of new BUA outside subdivided lots:
3547 sf
5194 sf
Parkinq (sQ ft
Sidewalk (sq ft
Roof (sg ft
2647 sf
4294 sf
Roadway s ft
Futures ft
900 sf
900 sf
Other, please specify in the comment box
below (sq ft
11
New infiltrating permeable pavement on
subdivided lots (sq ft
New infiltrating permeable pavement outside of
subdivided lots (sq ft
Exisitng BUA that will remain (not subject to
ermitting) (sq ft
12
13
34755 sf
4126 sf
14
_
Existing BUA that is already permitted (scl ft
15
Existing BUA that will be removed (sq ft
16
Percent BUA
70%
90%
17
Design storm inches
1 in
18 lDesigIn
volume of SCM cu ft
557 cf
19 lCalculation
method for desi n volume
Simple
ADDITIONAL
INFORMATION _ — _-
20 ldrainage
Please use this space to provide any additional information about the
areas :"
BAYFILTER
1
1 Drainage area number
1
2
Dasign volume (cu ft) or peak treatment rate (cfs) of SCM
F 557 cf
NE
MIDC FROM Q4AM
3
is the SCM sized to treat the SW from all surfaces at bulld-
out?
I Yes
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM (H:V)?
6
Does the SCM have retaining walls, gabion walls or other
engineered side slopes?
Are the inlets, outlets, and receiving stream protected from
erosion (10-year storm)?
No
7
Yes
B
Is there an overflow or bypass for inflow volume in excess of
the design volume?
Yes
9
What is the method for dewatering the SCM for
maintenance?
If applicable, will the SCM be cleaned out after construction?
Does the maintenance access comply with General MDC
(B)?
Pump .(preferred)
10
Yes
11
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
13
If the SCM is on a single family lot, does (will?) the plat
comply with _General MDC (10)?
Is there an O&M Agreement that complies with General
MDC (11)?
Is there an O&M Plan that complies with General MDC (12)?
14
Yes
15
Yes
16
Does the SCM follow the device specific MDC? Yes
the SCM designed by an NC licensed professional? Yes
MDC FROM THE STORMWATER DESIGN MANUAL
17 lWas
BAYFILTER
18
If Volume Design is used, what is the volume from the
drainage area (cubic feet)?
557 cf
19
Is an upstream detention used?
Yes
20
Volume of the upslope detenIon system (cubic feet)
5.70 cf
21
Percent of the design volume contained in the upslope
detention system (%)
100%
22
If Rate Based Sizing is used, for 1 inch or 1.5 inch (Coastal
areas). Water Quality flow rate for drainage area (cfs)
1
22 in _
< 953
23
Number of Cartridges
24
Cartridge height (inches)
25
SHWT elevation (fmsl)
26
Elevation. bf bottom of BayFifter vault (fmol)
955
27
Clearance from the SHWT (feet)
_
> 2
28
BayFilter Media Flow Rate (GPM/ft2 of Media Surface)
.50 gpm/sf
29
Does the system includes a sediment sump?
Yes
30
If yes, the diameter of the sump (feet)
4 ft
31
If yes, the depth of the sump (feet)
2 ft
32
Time to drain the sump (hours)
33
rime to drain the BayFilter (hours)
29 hrs
34
Is an off-line flow splitting device used?
Yes
35
Type of media used (EMC or GAC-metals)
EMC
36
Will maintenance be performed y Certified Maintenance
providers per instructions?
Yes
ADDITIONAL
INFORMATION
37
Please use this space to provide any additional information
about the BayFilter system(s):