Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG030423_MONITORING INFO_20190325 (FIX)
STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /V C. C, 63,0 � a 3 DOC TYPE ❑HISTORICAL FILE �k MONITORING REPORTS DOC DATE YYYYMMDD I a .10HBV DEERE March 20, 2019 Division of Water Resources (DWR) Attn: Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RECEIVE© MAR 2 5 Z019 C_N I KAL FILES DWR SECTION! RE: 2019 NPDES Storm Water Analytical Report 15l Half 2019 Records: John Deere Turf Care 6501 S NC 55 Hwy, Fuquay-Varina, NC 27526 Permit #: NGG030000 CoC #: NCG030423 Sean Weyrich Environmental Engineer Email: WeyrichSeanD@JohnDeere.com Enclosed is the storm water testing report for our facility for the first half of 2019 for outfall 4. On March 01, 2019 samples were collected from the site's representative outfall. Samples were collected by John Deere Turf Care Employee Sean Weyrich. The SDO sample was sent to Meritech, Inc — 642 Tamco Road, Reidsville, NC 27320 for analysis. The sample was analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with a HACH HQ440d (multi meter) on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Meritech, Inc. on 03/13/2019. Please note that on May 01, 2017 SDO 4 was granted representative outfall status for stormwater outfalls 2, 3 and 6. If you have any questions or comments, please contact me at 919-285-0350 at your convenience. Sincerely, 0( Sean Weyrich Environmental Engineer John Deere Turf Care Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 3/20/2019 CERTIFICATE OF COVERAGE NO. NCG03 0 4 2 3 FACILITY NAME John Deere Turf Care COUNTY wake PERSON COLLECTING SAMPLES Sean Weyrich LABORATORY Meritech, Inc. Lab Cert. # 165 Comments on sample collection or analysis: Samples collected at first flow and sent to Meritech, Inc. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD Q Jan -June ❑ July -Dec or ❑ Monthly' (month] DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow [—]water supply [:]SA ❑■ Other Black Creek, a class B; NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?2 Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Total Copper Total Lead Total Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks _ - 100 mg/L or 50 mg/O 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 SDo4 (PL) 3/1/2019 0.43 in 16 mg/L 7.36 0.003 mg/L 0.0005 mg/L 0.056 mg/L <5 mg/L 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Siva Sundaresan Name (Print name) Global Director, Commercial Mowing and Golf Equipment Title (Print title) Signature Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L" where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B. Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/ Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - - 15 mg/L 100 mg/L or 50 mg/O Parameter Code - 46529 NCOIL 00552 C0530 Footnotes from Part A also apply to Part B Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 i Page 2 of 3 FOR PART A AND PART B MONITORING RESULTS: A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES []NO[:] IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ®NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original copy of this DMR including all "No Discharge" reports, within 30 days o recei t of the lab results Lor at end of monitorinct periodin the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee Permit Date: 11/1/2018-05/31/2021 Go H A-U, M 7-0 1 y Date SWU-245, last revised 11/1/2018 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 11 07 2018 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES Sean We rich LABORATORY_Meritech, Inc. Lab Cert. # 165 Comments on sample collection or analysis: Samples collected at first flow and sent to Meritech. Inc. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2018 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' month FIGINGTOCLASS ❑ORW ❑HQW [:]Trout ❑PNA o�CG R �. E ❑Zero -flow ❑Water Supply ❑SA NOV 15 2018 ®Other Black Creek, a class B; NSW CENTRAL FILES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 DWR SECTION ❑ No discharge this period?' Outfall Na. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, IncheS3 Total Suspended Solids p pH' Standard units Ca Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics' Benchmarks ===> - - 100 mg/L or So mg/L° 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 4 (PL) 10/11/2018 2.40 23 mg/L 7.80 0.003 mg/L 0.0007 mg/L 0.045 mg/L <5 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. a See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General 'Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Siva Sundaresan Name (Print name) Global Director, Commercial Mowing and Golf Eq Title (Print title) 1, L.A 07 N o v tot S�- (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be resorted in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part 8: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Rate: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case o "No Discharge" reportsJ to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) 07 NoJ 20(g- (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 .IOHN DEERE November 07, 2018 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: 2018 NPDES Storm Water Analytical Report 2n" Half 2018 Records: John Deere Turf Care 6501 S NC 55 Hwy, Fuquay-Varina, NC 27526 Permit #: NCG030000 CoC #: NCG030423 Sean Weyrich Environmental Engineer Email: WeyrichSeanD@JohnDeere.com Enclosed is the storm water testing report for our facility for the second half of 2018 for outfall 4. On October 11, 2018 samples were collected from the site's representative outfall. Samples were collected by John Deere Turf Care Employee Sean Weyrich. The SDO sample was sent to Meritech, Inc — 642 Tamco Road, Reidsville, NC 27320 for analysis. The sample was analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. The pH reading was taken with a HACH HQ440d (multi meter) on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Meritech, Inc. on 11 /06/2018. Please note that on May 01, 2017 SDO 4 was granted representative outfall status for stormwater outfalls 2, 3 and 6. If you have any questions or comments, please contact me at 919-285-0350 at your convenience. Sincerely, Sean Weyrich Environmental Engineer John Deere Turf Care aJOHN DEERE July 17, 2018 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: 2018 NPDES Storm Water Analytical Report 15' Half 2018 Records: John Deere Turf Care 6501 S NC 55 Hwy, Fuquay-Varina, NC 27526 Permit #: NCG030000 CoC #: NCGO30423 Sean Weyrich Environmental Engineer Email: weyrichSeenD@JohnDeere.com EIVED JUL 24 2018 CENTRAL FILES DWR SECTION Enclosed is the storm water testing report for our facility for the first half of 2018 for outfall 4. On July 07, 2018 samples were collected from the site's representative outfall. Samples were collected by John Deere Turf Care Employee Sean Weyrich. The SDO sample was sent to Meritech, Inc — 642 Tamco Road, Reidsville, NC 27320 for analysis. The sample was analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with a HACH HQ440d (multi meter) on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Meritech, Inc. on 07/13/2018. Please note that on May 01, 2017 SDO 4 was granted representative outfall status for stormwater outfalls 2, 3 and 6. If you have any questions or comments, please contact me at 919-285-0350 at your convenience. Sincerely, Sean Environmental Engineer John Deere Turf Care Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 7/17/2018 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES Sean Weyrich LABORATORY Meritech, Inc. lab Cert. # 165 Comments on sample collection or analysis: Samples collected at first flow and sent to Meritech, Inc. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2018 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW [-]Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA Mother Black Creek, a class B; NSW JUL 2 4 2018 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR SECTION ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or s0 mg/L4 6.0 — 9.0 0.007 mg/L 0.030 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 4 (PL) 07/07/2018 0.53 17.3 mg/L 7.69 0.006 mg/L 0.0006 mg/L 0.041 mg/L <5 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfali. 2For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/16/2017-10/31/2018 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement forTTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." William Ducker Name (Print name) Operations Manager Title (Print title) (Sign ture) (Dade) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> - - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/16/2017-10/31/2018 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART It SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART Il SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (SignatureLof Perm -j_u4,, / 2 zal6 (Datey Permit Date: 11/16/2017-10/31/2018 SWU-245, last revised 10/25/2012 Page 3 of 3 JOHN DEERE October 30, 2017 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: 2017 NPDES Storm Water Analytical Report 211d Half 2017 Records: John Deere Turf Care 6501 S NC 55 Hwy, Fuquay-Varina, NC 27526 Permit #: NCGO30000 CoC #: NCGO30423 Sean Weyrich Environmental Engineer Email: WeyrichSeanD@JohnDeere.com RECEIVED NOV 47 Z017 CENTRAL RLES U,Wi� SECTION Enclosed is the storm water testing report for our facility for the second half of 2017 for outfall 4. On October 10, 2017 samples were collected from the site's representative outfall. Samples were collected by John Deere Turf Care Employee Sean Weyrich. The SDO sample was sent to Meritech, Inc — 642 Tamco Road, Reidsville, NC 27320 for analysis. The sample was analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. The pH reading was taken with a HACH HQ440d (multi meter) on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Meritech, Inc. on 10/25/2017. Please note that on May 01, 2017 SDO 4 was granted representative outfall status for stormwater outfalls 2, 3 and 6. If you have any questions or comments, please contact me at 919-285-0350 at your convenience. Sincerely, Sean Weyrich Environmental Engineer John Deere Turf Care Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 10/30/2017 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _ Sean Wevrich LABORATORY Meritech, Inc. Lab Cert. # 165 Comments on sample collection or analysis: Samples collected at first flow and sent to Meritech Inc. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2017 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' month DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA R E C E N M ®Other Black Creek, a class B; NSW NOV 0 7 2017 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 C.11%,'Tf—t-,i_ E=€_f=v �tf R c,7cC €ON ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics5 Benchmarks ===> _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 4 (PL) 10/10/2017 1.35 18 mg/L 6.60 0.003 mg/L 0.0009 mg/L 0.018 mg/L <5 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/l/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Fa dlities that incorporate a solvent management plan into the 5tormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (Tf0), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan.° Siva Sundaresan Name (Print name) Global Director, Commercial Mowing and Golf Eg� Title(Printtitle) T. Z 7-- 4L7_ o2.\3 1 (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L" where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS, SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) Z-4oC-T- aol�- (Date) Permit Date: 1i/i/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 6/12/2017 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES Sean Wevrich LABORATORY_Meritech, Inc. Lab Cert. # 165 Comments on sample collection or analysis: _Samples collected at first flow and sent to Meritech. Inc. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2017 SAMPLE PERIOD ® Jan -June ❑ July -Dec M!CEIVED or ❑ Monthly' _ (month SCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA JUN 19 2017 ❑Zero -flow ❑Water Supply ❑SA CENTRAL FILES Mother Black Creek a class B• NSW DWR SECTION PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 No discharge this period?Z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks -__> - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 4 (PL) 05/23/2017 1.09 5.0 mg/L 6.99 0.005 mg/L 0.0011 mg/L 0.018 mg/L <5 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Siva Sundaresan Name (Print name) Global Director Commercial Mowing and Golf E Title (Print title) (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX rn l." where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. !Vote: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/i/2012-101131/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier I, Tier 2, or Tier 3 responses. See General Permit text. FOR PART AAND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Moil an original and one copy of this DMR, including al! "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case o "No Discharge"' reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) r 2 3-1- zv r :4- (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 { JOHN DEERE John Deere Turf Care 6507 5 NC 55 Hwy, Fuquay-Varina, NC 27528 Permit #: NCGO30000 CoC #: NCG030423 Sean Weyrich Environmental Engineer Email: WeyrichSeanD@JohnDeere.com June 12, 2017 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: 2017 NPDES Storm Water Analytical Report 1 11 Half 2017 Records: Enclosed is the storm water testing report for our facility for the first half of 2017 for outfall 4. On May 23, 2017 samples were collected from the site's representative outfall. Samples were collected by John Deere Turf Care Employee Sean Weyrich. The SDO sample was sent to Meritech, Inc — 642 Tamco Road, Reidsville, NC 27320 for analysis. The sample was analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with a HACH HQ440d (multi meter) on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Meritech, Inc. on 06/06/2017. Please note that on May 01, 2017 SDO 4 was granted representative outfall status for stormwater outfalls 2, 3 and 6. If you have any questions or comments, please contact me at 919-285-0350 at your convenience. Sincerely, Sean Weyrich Environmental Engineer John Deere Turf Care Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 5/16/2017_ CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Sean Weyrich LABORATORY_Meritech, Inc. Lab Cert. # _165 Comments on sample collection or analysis:_ Samples collected at first flow and sent to the Meritech, Inc. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2017 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly'_ (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA RECEIVED ❑Zero -flow ❑Water Supply ❑SA ®Other Black Creek, a class B; NSW MAY 19 2011 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR-SECTION No discharge this period?2 Out#all No. Date Sample 1 Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic s Organics Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 2 (TF) 04/24/2017 3.78 38 mg/L 6.81 0.007 mg/L 0.0017 mg/L 0.037 mg/L <5mg/L z Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469,12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Siva Sundaresan Name (Print name) Global Director, Commercial Mowine and Golf Ea Title ((tPrint title) (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX me/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. n No discharge this period ?z Outfall No. Date Sample Collected; (mo/dd/yr) 24-hour rainfall amount, Inches; Non -polar O&G/TPH by EPA 1664 (5GT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 4.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 1, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." VU,:=:� - - (Signature of Permittee) Permit Date: 11/1/2012-10/31/2017 16 M o-y 2L) 17 (Date) SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 05/16/17 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Sean Weyrich LABORATORY Meritech, Inc. Lab Cert. # 165 Comments on sample collection or analysis: Samples collected at first flow and sent to the Meritech, Inc. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2017 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ®Other Black Creek a class B• NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 IHydrocarbons .Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Toxic Organics' Benchmarks =__> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.030 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 6 (BY) 04/24/2017 3.78 18 mg/L 6.35 0.007 mg/L <0.0005 mg/L 0.038 mg/L <5 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the stormwater Pollution Prevention Plan." Siva Sundaresan Name (Print name) Global Director, Commercial_Mowing and Golf Eq Title (Print title) (Signature) — r 6 '1ai 2-011 (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L" where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. [] No discharge this period ?2 Outfall No. Date Sample Collectedl (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids - pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 su Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an on inal and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lob results or at end of monitoring eriod in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) I b 2-0 (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 page 3 of 3 JOHN DEERS May 16, 2017 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: 2017 NPDES Storm Water Analytical Report 1st Half 2017 Records: John Deere Turf Care ` 6501 S NC 55 Hwy, Fuquay-Varina, NC 27526 Permit #: NCG030000 CoC #: NCG030423 Sean Weyrich Environmental Engineer Email: WeyrichSeanD@John0eere.com Enclosed is the storm water testing report for our facility for the first half of 2017 for outfalls 2 and 6. On April 24, 2017 samples were collected from two of the discharge outfalls. Samples were collected by John Deere Turf Care Employee Sean Weyrich. SDO samples were sent to Meritech, Inc — 642 Tamco Road, Reidsville, NC 27320 for analysis. The samples were analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with a HACH H0440d (multi meter) on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Meritech, Inc. on 05/08/2017. Please note the initial copper results for both outfalls were 0.008 mg/L which exceeded the benchmark limit. Both samples were retested for copper on 05/10/2017 by Meritech, Inc. and both results were 0.007 mg/L meeting the benchmark limit. After contacting and receiving guidance from NC DEQ — DEMLR (Raleigh Regional), the retested values meeting the limit were reported on form SWU 245. If you have any questions or comments, please contact me at 919-285-0350 at your convenience. Sincerely, '0" Sean Weyrich Environmental Engineer John Deere Turf Care Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 01/03/17 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Sean Weyrich LABORATORY Anal ics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Unable to obtain samples (No Flow)._ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2016 SAMPLE PERIOD ❑ Jan -June ® July -Dec or [] Monthly' month � � �{ ,,: CkiARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA JAN j V [�J ❑Zero -flow ❑Water Supply ❑SA Q 2017 ®Other Black Creek, a class B; NSW DENTEC PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 -� � S�CI-ION 774N ® No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks =__> _ - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 4 (PL) 2"d Half (No Flow) - - - - - - ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for.those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/2S/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the stormwater Pollution Prevention Plan." Siva Sundaresan Name (Print name) Global Director, Commercial Mowing and Golf Eq Title (Print title) (� k ' C)1, (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: !f you report a sample value in excess of the benchmark, you must implement Tier I, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =_=> _ - 1S mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See Genera! Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART I I SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring Period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) 0 3 2--017 (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 01/03/17 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Sean Weyrich LABORATORY_Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Unable to obtain samples No Flow). Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2016 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' _ (month) DISCHARGING TO CLASS ❑ORW ❑HQW []Trout ❑PNA ❑Zero -flow ❑Water Supply [:]SA ®Other Black Creek, a class B;NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 --> ® No discharge this period:2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks =__> _ - 100 mg/L or 50 mg/O 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 2 (TF) 2nd Half (No Flow) - - - - - - 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. ' Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Siva Sundaresan Name (Print name) Global Director, Commercial MowinP and Golf EQ Title (Print title) (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX m L" where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. !Vote: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar 0&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDANCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an on inal and one copy of this DMR including all "No Dischar e" re orts within 30 days of receipt of the lab results or at end of monitoring eriod in the case of "No Discharge" reports! to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) 01, ,� f v� 2-Pk j (Date) Permit Date: 11/1/2012-10/31/2017 SWIJ-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 12/22/16 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES Sean Weyrich LABORATORY Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2016 SAMPLE PERIOD ❑ tan -June ® July -Dec or ❑ Monthly[ [month) DISCHABING TO CLASS ❑ORW ❑HQW [:]Trout❑PNA RECEIVE ❑Zero -flow ❑Water Supply ❑SA JAN e 6 2W ®other Black Creek, a class_BLNSW CENTRAL FILES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 DVVR SECTION No discharge this period:' Outfall No. Date Sample Collected' (mo/dd/yr) 24rainfall amount, Inches' Total Suspended Solids pH, Standard units Copper lead Zinc Non-Polar O&G/hour Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/O 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 3 (WS) 12/06/2016 0.40 3.2 mg/L 6.79 0.00739 mg/L <0.005 mg/L 0.0711 mg/L <5 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/l/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Siva Sundaresan Name (Print name) Global Director, Commercial Mowing and Golf Ea Title (Print title) T. 12 -21 -zo16 (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX ma/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids psi Benchmarks =_ _> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SLI Footnotes from Part A also apply to this Part B See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement firer 1, Tier 2, or T7er 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: r A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one cony of this OMR including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) Permit Date:11/1/2012-10/31/2017 12- 7-1 - Z011o (Date) SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 12/22/16 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES -Sean Wevrich LABORATORY Analvtics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2016 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly) (Month) DISCHARGING TO CLASS ❑ORW ❑HQW [—]Trout ❑PNA ❑Zero -flow ❑Water Supply []SA ®Other Black Creek a class B• NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 El No discharge this period?' Outfall No. Date Sample Collected) 24-hour rainfall amount, Inche53 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics-' Benchmarks =__> _ - 100 mg/L or 50 mg/O 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 6 (BY) 12/06/2016 0.40 17.2 mg/L 7.00 0.0081 mg/L <0.005 mg/L 0.0629 mg/L <5.00 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. a See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the stormwater Pollution Prevention Plan." Siva Sundaresan Name (Print name) Global Director, Commercial Mowing and Golf Ea. Title (Print title) 2 21 -- Zola (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX me/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Mote: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See Genera! Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period ?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 4.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/l/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reportsi to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." K-A, 17, 2I —201(, (Signature of Permittee) Permit Date: 11/1/2012-10/31/2017 (Date) SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 12/22/16 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Sean Weyrich LABORATORY Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2016 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' _ (month) � ��1DIS RGING TO CLASS ❑ORW ❑HQW [:]Trout❑PNA R VV ❑Zero -flow ❑Water Supply ❑SA JAN 9 6 2017 ®Other Black Creek, a class B; NSW CENTRAL" FILES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 DIJ` R SECTION No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics' Benchmarks ===> _ I - 100 mg/L or 50 mg/L° 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 3 (WO) 12/06/2016 0.40 3.2 mg/L 6.79 0.00738 mg/L <0.005 mg/L 0.0711 mg/L <5 mg/L 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. ZFor sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. ' Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Siva Sundaresan Name (Print name) Global Director, Commercial Mowing and Golf Eg Title (Print title) t2 _21 -7,0t6 (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS, SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) 12- 21 - 2.0�� (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 JOHN DEERE December 22, 2016 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: 2016 NPDES Storm Water Analytical Report 2nd Half 2016 Records: John Deere Turf Care 6501 S NC 55 Hwy, Fuquay-Varina, NC 27526 Permit #: NCG030000 CoC #: NCG030423 Sean Weyrich Environmental Engineer Email: WeyrichSeanD@JohnDeere.com RECEIVED JAN 4 6 2017 CENTRAL FILES DWR SECTION Enclosed is the storm water testing report for our facility for the second half of 2016 for outfalls 3 and 6. On December 06, 2016 samples were collected from two of the four discharge outfalls. Samples were collected by John Deere Turf Care Employee Sean Weyrich. SDO samples were sent to Analytics Corporation -- 10329 Stony Run Lane, Ashland VA, 23005 for analysis. The samples were analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with a HACH HQ440d (multi meter) on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Analytics Corporation on 12119/2016. Please note, the results for outfall 3 generated benchmark exceedances for Copper and Zinc. Similarly, we had a Copper benchmark exceedance for outfall 6. Turf Care recognizes we have entered Tier One and are working to institute all corrective actions and management strategies designated under the Tier One category contained within the NPDES permit. If you have any questions or comments, please contact me at 919-285-0350 at your convenience. Sincerely, Sean Weyrich Environmental Engineer John Deere Turf Care Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 7/14/2016 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Sean Weyrich LABORATORY Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow and sent to the Analytics Corporation._ Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2016 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly' month DI CHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA �lVE ❑Zero flow [:]Water Supply [:]SARTC rNOther Black Creek, a class B; NSW L FILES PLEASE,REMEMBER TO SIGN ON PAGES 2 AND/OR 3 CENTRAs DWR S>~G�IGS -V'" ❑ No discharge this period?' Date Sample 24-hour rainfall pr Non -Polar O&G/ Total Toxic Outfall No. Collected amount, Total Suspended Solids Standard d units Copper Lead Zinc Total Petroleum Organics s (mo/dd/yr] 3, Inches Hydrocarbons Benchmarks ===> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 2 (TF) 06/28/2016 0.73 54.9 mg/L 7.82 <0.005 mg/L <0.005 mg/L 0.0197 <5.00 mg/L mg/L 1 RR m f 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. l further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." William Dueker Name (Print name) Business Unit Manager —Golf & Turf. Title (Print title) w �y !6 (Signal e) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. No discharge this period ?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks ==_> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note.. if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS, SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO 1F YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports within 30 do vs otreceipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of P Z(lIV11G (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 aJOHN DEERE July 14, 2016 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: 2016 NPDES Storm Water Analytical Report 15t Half 2016 Records: John Deere Turf Care 6501 S NC 55 Hwy, Fuquay-Varina, NC 27526 Permit #: NCG030000 CoC #: NCG030423 Sean Weyrich Environmental Engineer Email: WeyrichSeanD@JohnDeere.com JUL 18 1Ulo CENTRAL FILES DWR SECTION Enclosed is the storm water testing report for our facility for the first half of 2016 for outfall 2. On June 28, 2016 samples were collected from one of the four discharge outfalls. Samples were collected by John Deere Turf Care Employee Sean Weyrich. SDO samples were sent to Analytics Corporation — 10329 Stony Run Lane, Ashland VA, 23005 for analysis. The samples were analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with a HACH HQ440d (multi meter) on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Analytics Corporation on 07/11/2016. Please note, results for outfalls 3 and 4 were previously sent on May 10, 2016 and outfall 6 was submitted separately on June 03, 2016. The attached report completes our site's semi- annual analytical monitoring requirement for the first half of 2016. The reported total precipitation value was obtained from a local rain gauge due to inaccurate reporting of our on -site gauge. If you have any questions or comments, please contact me at 919-285-0350 at your convenience. Sincerely, Sean Weyrich Environmental Engineer John Deere Turf Care Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 06/03/16 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Sean Weyrich All LABORATORY Analvtics Corporation. Lab Cert. # 459 'U"Jc Comments on sample collection or analysis: -Samples collected at first flow and sent to the Analytics Corporation. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2016 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly) (month) DISCHARGING TO CLASS ❑ORW ❑HCfW ❑Trout ❑PNA r1 ❑Zero -flow ❑Water Supply [—]SA n ft ®Other Black Creek, a class C; NSW JUG! 0 7 Zal6PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR SECTION ❑ No discharge this period?2 Date Sample 24-hour rainfall pH, Non -Polar O&G/ Total Toxic Outfall No. Collected' amount, Total Suspended Solids standard units Copper Lead Zinc Total Petroleum Organics (mo/dd/yr) Inches3 Hydrocarbons Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 - 9.0 0.007 mg/L 0.030 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 6 (BY) 05/17/2016 0.09 4.8 mg/L 7.06 <0.005 mg/L <0.005 mg/L 0.0581 <5.00 mg/L mg/L n r 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. a See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For thdse facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Rosalind Fox Name (Print name) Factory Manaeer int title) (Signature) (Dat ) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour.rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks ===> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part 8 * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART• A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lob results (or at end of monitoring period in the case o "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." i n o v��-CCU iture of Permittee) (,; 3 r� (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 aJOHN DEERE June 03, 2016 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: 2016 NPDES Storm Water Analytical Report 151 Half 2016 Records: John Deere Turf Care 6501 S NC 55 Hwy. Fuquay-Varina, NC 27526 Permit #: NCG030000 CoC #: NCGO30423 Sean Weyrich Environmental Engineer Email: WeyrichSeanD@JohnDeere.com Enclosed is the storm water testing report for our facility for the first half of 2016 for outfall 6. On May 17, 2016 samples were collected from one of the four discharge outfalls. Samples were collected by John Deere Turf Care Employee Sean Weyrich. SDO samples were sent -to Analytics Corporation — 10329 Stony Run Lane, Ashland VA, 23005 for analysis. The samples were analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with a HACH HQ440d (multi meter) on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Analytics Corporation on 05/31/2016, Please note, results for outfalls 3 and 4 were previously sent on May 10, 2016. If you have any questions or comments, please contact me at 919-285-0350 at your convenience. Sincerely, Sean Weyrich Environmental Engineer John Deere Turf Care A �oSemi-annual Stormwater Discharge MonitoringReportD for North Carolina Division of Water Quality General Permit No. NCGf030000 Date submitted _ _5/10/2016 0 *4 CERTIFICATE OF COVERAGE NO. NCG030423 SAMPLE COLLECTION YEAR 2016 FACILITY NAME John Deere Turf Care SAMPLE PERIOD ® Jan -June ❑ July -Dec COUNTY Wake or ❑ Monthly' fmonth) PERSON COLLECTING SAMPLES _Matt Williams DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA LABORATORY_Analytics Corporation. Lab Cert. i# 459 ❑Zero -flow ❑Water Supply [:]SAComments on sample collection or analysis: Samples collected at RECEIVED ®Other Black Creek a class C• NSW first flow MAY 16 2016 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 LES Part A: Stormwater Benchmarks and MonitoringResults CENTRAL SECTION OU�1R SECTION ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics5 Benchmarks ===> - - 100 mg/L or 50 mg/O 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 3 (WB) 04/12/2016 0.73 33.0 mg/L 7.89 <0.005 mg/L <0.005 mg/L 0.0256 mg/L <5 mg/L Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. S Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469,31). :U Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 P.'i6P 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Rosalind Fox Name (Print name) Factory Manager Print (Signature) (Dalie) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B. Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period ?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH genchmarks =_=> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results or at end of monitoring eriod in the case o "No Discharge"" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) fqll� (D te) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring_ Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 5/10/2016 CERTIFICATE OF COVERAGE NO. N00030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Matt Williams LABORATORY Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow. Part A: 5tormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2016 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly' (months DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply [:]SA RECEIVED ®Other Black Creek, a class C; NSW MAY 16 2016 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL FILES DWR SECTION ❑ No dischorge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, Standard units Copper Lead Zinc Nan -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics' Benchmarks ===> - - 100 mg/L or 50 mg/L° 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO4 (PL) 04/12/2016 0.73 5.60 mg/L 7.51 <0.005 mg/L <0.005 mg/L 0.0105 mg/L <5 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. a See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Rosalind Fox Name (Print name) Factory Manager „ e (Print title) 66 ( ignature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the forma "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days 9f receipt of the lab results (or at end of monitoring period in the case of "No Discharge' reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." S4�Z A_�k �ZX r-t f c-P re of Permittee) (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 aJOHN DEERS May 10, 2016 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 RE: 2016 NPDES Storm Water Analytical Report 151 Half 2016 Records: John Deere Turf Care 6501 S NC 55 Hwy, Fuquay-Varina, NC 27526 Permit #: NCGO30000 CoC #: NCG030423 Sean Weyrich Environmental Engineer Email: Weyrich SeanD@JohnDeere.com Enclosed is the storm water testing report for our facility for the first half of 2016. On April 12, 2016 samples were collected from two of the four discharge outfalls. Samples were collected by John Deere Turf Care Employee Matt Williams. SDO samples were sent to Analytics Corporation — 10329 Stony Run Lane, Ashland VA, 23005 for analysis. The samples were analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with a HACH HQ440d (multi meter) on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Analytics Corporation on 04/22/2016. If you have any questions or comments, please contact me at 919-285-0350 at your convenience. Sincerely, Sean Weyrich Environmental Engineer John Deere Turf Care Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water ()unlit General Permit No NCG030000 Y Date submitted 12/8/15 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Zada Barnes LABORATORY Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow and sent to the Anal ics Corporation. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2015 SAMPLE PERIOD ❑ Jan -June ® July -Dec or 0 Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA RECEIVED ®Other Black Creek, a class C; NSW oEc i 4 2015 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 oWRRAL FILES S CTION ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks ===> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 2 (TF) 11/19/2015 1.51 6.4 mg/L 6.51 <0.005 mg/L <0.005 mg/L 0.0198 mg/L <5 mg/L 2 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfalf. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433,11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Rosalind Fox Name (Print name) Factory Manager (Print tit ) (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period: Outfal] No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks ===> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2of3 Nc-te: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text, FOR PART'A AND PART B MONITORING RESULTS: + A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results or at end of monitorin period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 1 b1 e � LA-4 re of Permittee) (&I l� (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 12/8/15 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Zada Barnes LABORATORY_Anaiytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2015 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' _ (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow []water Supply ❑SA ®Other Black Creek, a class C; NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?Z Outfall No. Date Sample Collected) (mo/dd/yr) 24-hour rainfall amount, Inches35 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 3 (WB) 11/19/2015 1.51 12.6 mg/L 6.38 <0.005 mg/L <0.005 mg/L 0.0572 mg/L <5 mg/L 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469,12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the Stormwater or areas which are exposed to rainfall or Stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Rosalind Fox Name (Print name) Factory Manager _PLWJPrint title) AX - (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format. "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part 6: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected" (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PARTA AND PART 8 MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results tor at end of monitoring period in the case of "No Dis_ch_arae" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 2 of Permittee) Ea g ' 5 (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge MonitoringReport for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted _ 12/8/15 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Matt Williams LABORATORY Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2015 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' month DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ®Other Black Creek, a class C; NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?2 Outfall No. Date Sample Collected; (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics; Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 4 (PL) 11/19/2015 1.51 16.6 mg/L 7.37 <0.005 mg/L <0.005 mg/L 0.0213mg/L <5 mg/L 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3 The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the 5tormwater Pollution Prevention Plan." Rosalind Fox Name (Print name) Factory Manager Titip title) .,4j - p-lglts (Signature) (Date} Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX_mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 1, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period? Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L« 6.0 -- 9.0 SU Footnotes from Part A also apply to this Part 8 * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER ATANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case o "No Discharge' reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significRnt penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (SignatUre of Permittee) fa (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 12/8/15 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wa PERSON COLLECTING SAMPLES Matt Williams LABORATORY Anallqics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow and sent to the Analytics Corporation. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2015 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ®Other Black Creek, a class C; NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organicss Benchmarks ===> - - 100 mg/L or 50 mg/L 6,0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 6 (BY) 11/19/2015 1.51 3.7 mg/L 7.49 <0.005 mg/L <0.005 mg/L 0,0197 mg/L 6.6 mg/L 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit'the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433,11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Rosalind Fox Name (Print name) Factory Manager � � S (Signature) (Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX me/O where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. !Vote. if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > SS gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected} (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L' 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 1, or Tier responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR including all "No Discharge," reports, within 30 days of receipt of the lab results or at end of monitoring eriod in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) Permit Date: 11/1/2012-10/31/2017 (Date) SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted _4/1/2015 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Philip Keegan LABORATORY Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: _Samples collected at first flow and sent to the Analytics Corporation. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2015 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA []Zero -flow [:]Watersupply ❑SA C � � ®Other Black Creek, a class NSW APR p $ 1�?�EASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 CENTRAL- TION pWR SEC ❑ No discharge this period?2 Outfall No. Date Sample Collected" (mo/dd/yr) 24rainfall amount, inches3 Total Suspended Solids pH, standard units Copper Lead Zinc Non-Polar O&G/hour Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks ==_> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 2 03/19/2015 .73 10.1 mg/L 7.71 <0.005 mg/L <0.005 mg/L 0.036 mg/L <5 mg/L 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-24S, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring 'may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Storm ater Pollution Prevention Plan." ALA N�D F-ax Name (Print name) rAC:'(_D0I/ r-.1AGE� T rint title) % x A5 (Signature) (D te) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. (Vote: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, inches3 Non -polar O&G/TPH by EPA 1664 (sGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part 8 * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART li SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an on final and one copy of this WAR including all "No Dischar e" reports, within 30 da s of repel t of the lab results or at end of monitoring period in the case of "No Discharge"' reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 4// 1�,5 (Sign ture of Permittee) (DAte) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report .. for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 4/1/2015 CERTIFICATE OF COVERAGE NO. NCG030423 SAMPLE COLLECTION YEAR 2015� FACILITY NAME John Deere Turf Care SAMPLE PERIOD ® Jan -June ❑ July -Dec COUNTY Wake or ❑ Monthly' (month) PERSON COLLECTING SAMPLES _Philip Keegan DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA� ❑Zero -flow ❑Water Supply ❑SA LABORATORY Analytics Corporation. Lab Cert. # 459 _� Comments on sample collection or analysis: Samples collected at RECEIVED ®Other Black Creek, a class C�LS_�� first flow APR 0 8 1l135 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/003&-)� CENTRAL FILES Part A: Stormwater Benchmarks and Monitoring Results DWR SECTION ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches, Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L 5DO 3 (WB) 03/19/2015 .73 6.4 mg/L 7.14 <0.005 mg/L <0.005 mg/L 0.048 mg/L <5 mg/L 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General "rtrmit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the stormwater Pollution Prevention Plan." 12 Name (Print name) FAC.To2y H A 1,44OtG (Print title) a (5igna ure) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?2 Outfall No. Date Sample Collected" (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 4.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including ail "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports} to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." S� aax of Permittee} !� (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 JOHN DEERE TURF CARE 650E S NC 55 Ilwy, MQUAY-VARINA, NORTI I CAROLINA 27526; TEiL (919)567-6400 FAX (919) 567-6648 JOHN DEERE April 1, 2015 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 Re: 2015 NPDI_S Storm Water Analytical Report I st Half 2015 John Deere Turf Care 6501 S NC 55 Hwy Fuquay-Varina, NC 27526 Permit # NCG030000 CoC # NCG030423 Records: Enclosed is the storm water testing report for our facility for the first half of 2015. On March 19, 2015 samples were collected from all the discharge outfalls. Samples were collected by John Deere Turf Care Employee Philip Keegan. Both SDO samples were sent to Analytics Corporation — 10329 Stony Run Lane, Ashland VA, 23005 for analysis. The samples were analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with an Oakton pHTestr30 on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Analytics Corporation on 3/31/2015. If you have any questions or comments, please contact me at (919) 285-0338 at your convenience. Sincerely, Philip Keegan — Environmental Engineer John Deere Turf Care M' Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 4/1/2015 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Philip Keegan LABORATORY Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2015 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly' month RECEIVE /CCPCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA R V GV ❑Zero -flow []Water Supply ❑SA APR D 5 t= ®Other Black Creek, a class C: NSW &&8 CENTRAL FILES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 DWR SECTION ❑ No discharge this period?' Outfall No. Date Sample Collected'' (mo/dd/yr) 24-hour rainfall amount, Inches Total Suspended Solids PH,Non-Polar Standard units Copper Lead Zinc O&G/ Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L i mg/L SDO4 (PL) 03/19/2015 .73 <2.50 mg/L 8.2 <0.005 mg/L <0.005 mg/L 0.0238 mg/L <5 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. `See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities V, at incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring 'may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." �S A r-I &AD FCK Name (Print name) KINAG-OZ Title (Print title) �__a x 4 A fi -5 (Signature) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. !Vote: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. r FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCI_EDENCES FOR THE SAME PARAMETER AT ANYONE OLITFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of onitorin eriod in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." re of Permitteea 4 It 5 (D e) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted _4/1/2015 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care _ COUNTY Wake PERSON COLLECTING SAMPLES —Philip Keegan LABORATORY Analytics Corporation, Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow and sent to the Analytics Corporation. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2015 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly" "month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply [—]SA RECEIVED ®Other Black Creek, a class C; NSW APR 0 8 L015 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 CENTRAL Fi DWR SEC71pN ❑ No discharge this period?2 4 Outfall No. Date Sample Collected" (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks ==> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 6( ay� 03/19/2015 .73 2.9 mg/L 7.34 <0.005 mg/L <0.005 mg/L 0.0473 mg/L <5 mg/L 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. `See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General w Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the St water Pollution Prevention Plan." QS L(N( FO Y, Name (Print name) Ztitle) '01 (Signature) (Dat) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L" where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement tier 1, Tier 2, or tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?Z Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =_-> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWLI-245, last revised 10/25/2012 Page 2 of 3 Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART it SECTION B. • TTER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mall an original and one copy of this DMR including all "No Dischar e" reports, within 30 days of receipt of the lab results or at end of monitoring eriod in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." MIN (Signature of Permittee) -4//// (D e) V. Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 .RNALYTICS March 31, 2015 PHILIP KEEGAN JOHN DEERE TURF CARE, INC 5501 NC HIGHWAY 55 EAST Fuquay Varina, NC 27526 Account ID: 32401015 STANDARD Purchase Order: 4501457655 Client ID: JDTC FIRST 112 2015 STORMWATER Work Order: 1025640 Dear PHILIP KEEGAN Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Enclosed are the analytical results for sampte(s) received by the laboratory on Tuesday, March 24, 2015. The signature below certifies that the results are based on the referenced methods and applicable certifications or accreditations are noted for each parameter reported (see key at end of report), Unless otherwise specified all analyses of solid materials are based on dry weight Reported results relate only to the items tested, as received by the laboratory. On -site analysis (analysis ASAP) is recommended for the following tests: pH, temperature, dissolved oxygen, residual chlorine and sulfite. When performed off -site, these tests do not meet NELAC standards. Abbreviations:uglL = micrograms per Liter, mglL = milligrams per Liter, uglg = micrograms per gram, mg/kg = milligrams per kilogram uglwp = micrograms per wipe, ug/ml = micrograms per millimeter, US/cm = microsiemens per centimeter at 25 degrees Celcius ppb = parts per billion, DF = Dilution Factor. If you have any questions concerning this report, please feel free to call Client Services at 1-800-888-8061. Sincerely, Dawn Ca to Technical Director (or designee) Enclosures ReportID: 1025640-20150331163838 CERTIFICATE OF ANALYSIS Page 1 of 4 This report shall not be reproduced, except in full, without the written consent of Analytics Corporation ,OPLANALYTICS ANALYTICAL RESULTS Analytics Corporation 10329 Stony Run Large Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Workorder: 1025640 JDTC FIRST 1/2 2015 STORMWATER Lab ID: 1025840001 Date Received: 03/24/2015 9:40 Matrix Aqueous Liquid Sample ID: WB-OIL & GREASE-TSS-METALS Date Collected: 03/19/2015 17:47 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications -Analytical Method: EPA 1664A Hexane Extractable Material <5.00 mg/L 5.00 1 NA NA 3/26/2015 07:15 RTL V Analytical Method: - _ EPA 200.8 — —T - — Preparation Method_ EPA 200.8 - - - — Copper <0.00500 mg/L 0.0050 1 03/27/2015 08:21 JRM 3/30/2015 12:02 HB V <0,00500 mg/L 0.0050 1 03/27/2015 08:21 JRM 3/30/2015 12:02 HB i V Zinc 0,0480 _ mg1L 0.0100 1 03/27/2015 08:21 JRM 3/30/2015 12.02 HB V —Preparation Method: SM254OD-2011 _ J Analytical Method: SM254OD-2011 Total Suspended Solids 6.40 mg/L 2.50 1 03/25/2015 16:15 AMW 3/26/2015 14:45 AMW V Report ID: 1025640-20150331163838 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 2 of 4 XANALYTICS ANALYTICAL RESULTS Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Workorder: 1025640 JDTC FIRST 1/2 2015 STORMWATER Lab iD: 1025640002 Date Received: 03/24/2015 9:40 Matrix Aqueous Liquid Sample 1D: BY -OIL & GREASE-TSS-METALS Date Collected: 03/19/2015 17:56 Sample Type: GRAB Parameters Results Units Report Lim! DF Prepared By ' Analytical Method: EPA 1664A Analyzed By Qual Certifications Hexane Extractable Material <5.00 mg/L 5.00 1 NA NA 3/26/2015 07:15 RTL V Analytical Method: EPA 200.8 Preparation Method: EPA 200.8 — f 1 _ Copper <0.00500 mg/L 0.0050 1 03/27/2016 08:21 JRM 3/30/2015 12:07 HB V Lead <0.00500 mg/L 0.0050 1 03/27/2016 08:21 JRM 3/30/2015 12:07 HB V Zinc 0.0473 mg/L 0.0100 1 03/27/2015 —08:21 JRM 3/30/2015 12:07 HB V Analytical Method: SM2540D-2011 Total Suspended Solids 2.90 Report ID: 1025540-20150331163836 mg/L Preparation Method: SM2540D-2011 2.50 1 03/25/2016 16:15 AMW 3/26/2015 14:45 AMW V CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 3 of 4 �ia.NALYTICS ANALYTICAL RESULTS Workorder: 1025640 JDTC FIRST 1/2 2015 STORMWATER Qualifiers Certification Index: V = Virginia (NELAC) - 1 VAC 30-46 H 1, Laboratory 10: 460160, Certificate M 7668 Report ID: 1025640-20150331163838 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Page 4 of 4 ENVIRONMENTAL CHAIN OF CUSTODY U A A R RA1 SHIPPED 3 # OF SANIFLES Q PROJECT NAME OR NUM_B�E�}R-- �-7 - >i •i 't `i1� T L0I � r cJ �� C- t t, S �Pi� r Y �J;?A�a LEERE TJ�-?f= CARE, Ii` C ? ? Ca. __ i �I 4W/7 0-A= _ __, P,URCHASEZRDERNO: CONTACT I r� : ITIEUPHONENUMBER' {�L, -J rJ� +9 Q i �4�1 NC H1G'HWAY 5 EAST � � RUSH ANALYSIS Ir MAIL ADDRESS: FUDIJA z'—VARiNA, NC 2 7 a2C F2h o n e : 919-56 7 —6449 10329 Stony Run Lane Ashland, VA 23005 Fax: 1-919-567-6648 Same Dayr i,�,'i One Day - Phone (804) 365-3000 SPECIAL IN : RUCTIONS: =' Rf ; # - -; - e-10 a u E Two Day Toll Free (800) 888-8061 C Three Day Fax (804) 365-3002 Extra Charge - 1. r MATRIX CODES" ANALYSIS REQUESTED (Place an "X" in the box below to indicate request) V Preservative Temperature on Arrival A = AQUEOUS 0 = Olt Q ZiYes S = SOLID X = OTHER X 2 U Received an Ice: C3 No ✓1 1 _ i DW = DRINKING WATER W = WIPES m ag' A!. P Z a o ` �� �7 I Y (n U z° COMMENTS Lab ID Sample Identification Date & Time g � 0 _ _ _Z.O. 13101Is 6W A I 2 6-1 X I I I I I I I I I X i Cr x I I we- I? - �� i CT_ I x x I I BY - a� { �-Cr►�,s oofsSG IBy- 1SS AI 1 G X71 Ey- =- >ils.* AID I lx x II I SAMPLED73YPINT NAME):- - SAM}?EED 6Y (SIGNATURE TO INITIATE COL} , _ _ DATE - 71ME - ~ - rSAMPLES RECEIVED BY: F r - Y - PEES RELINQUISHED BY {SIGNATURE) DATE TIME CONDITION:- ,. {SIGNATURE) - DATE - - TIME CONDITfON - - A CATLYM � L5 �- 1 f E NVCCC-01 I REV. 4/2012) . ANALYTISS Work Order: 1025640 Customer Name: JOHN DEERE TURF CARE, INC 32401015 STAND Sample Container Receipt Form Version 6-24-2011 CLIENT SAMPLE ID LAB CONTAINER ID TYPE OF CONTAINER QTY Temp(C) pH Chlorine on Condition Code Arrival (ppm) Preservative f WB-OIL & GREASE-1 1025M0001-C 1000G ( 1 12 E OK HCL j WB-0IL $ GREASE-1 1025640001-B j 1000G 1 j 2 j OK j HCL E E WB-0IL & GREASE-1025640001-D 1000P 1 2 8 OK COOL WB-OIL & GREASE-1025640001-A 500P 1 ' 2 8 OK COOL BY -OIL & GREASE- 1025640002-B 1000G 1 2 i (OK HCL BY -OIL & GREASE- 1025640002-A 500P 1 2 8 ! OK COOL BY -OIL & GREASE- 1025640002-D j 1000P 1 k 2 8 OK E COOL BY-0iL & GREASE- 1025640002-C 1000G 1 2 4 I OK f HCL Notes' Custodian Signature Date: zw 1-5 Version 11-13-2011 CML Page 1 of 1 /fANALYTICS March 31, 2015 PHILIP KEEGAN JOHN DEERE TURF CARE, INC 5501 NC HIGHWAY 55 EAST Fuquay Varina, NC 27526 Account 0; 32401015 STANDARD Purchase Order: 4501457655 Client ID: JDTC FIRST 112 2015 STORMWATER Worts Order, 1025639 Dear PHILIP KEEGAN Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Enclosed are the analytical results for sample(s) received by the laboratory on Tuesday, March 24, 2015. The signature below certifies that the results are based on the referenced methods and applicable certifications or accreditations are noted for each parameter reported (see key at end of report). Unless otherwise specified all analyses of solid materials are based on dry weight, Reported results relate only to the items tested, as received by the laboratory On -site analysis (analysis ASAP) is recommended for the following tests: pH, temperature, dissolved oxygen, residual chlorine and sulfite. When performed off -site, these tests do not meet NELAC standards. Abbreviations:ug/L = micrograms per Liter, mg/L = milligrams per Liter, ug/g = micrograms per gram, mg/kg = milligrams per kilogram ug/wp = micrograms per wipe, uglml = micrograms per millimeter, uS/cm = microsiemens per centimeter at 25 degrees Celcius ppb = parts per billion, DF = Dilution Factor. If you have any questions concerning this a report, please feel free to call Client Services at 1-800-888-8061, Sincerely, " Dawn C to Technical Director (or designee) Enclosures Report ID: 1025639-20150331163838 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 1 of 4 ,otANALYTics ANALYTICAL RESULTS Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Workorder: 1025639 JDTC FIRST 112 2015 STQRMWATER Lab ID: 1025639001 Date Received: 03/24/2015 9:40 Matrix Aqueous Liquid Sample ID: PL-OIL 8 GREASE-TSS-METALS Date Collected: 03/19/2015 17:25 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications Analytical Method: EPA 1664A� Hexane Extractable Material <5.00 mglL 5.00 1 NA NA 3126/2015 07:15 RTL V Analytical Method EPA 200.8 — — Preparation Method_ EPA 200.8 Copper <0.00500 mglL 0.0050 1 03/27/2015 08:21 JRM 3/30/2015 11:41 HB V Lead <0. 00500 mg/L 0.0050 1 03/27/2015 08:21 JRM 3/30/2015 11:41 HB V Zinc 0.0238 mglL 0.0100 1 03/27/2015 08:21 JRM 3/30/2015 11:41 HB V Preparation Method: SM2540D-2011 Analytical Method SM254DD-2011 Total Suspended Solids <2.50 mglL 2.50 1 03/25/2015 16:15 AMW 3/26/2015 14:45 AMW V Report ID: 1025639-20150331163838 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 2 of 4 ,4AhUALYTIC'�r ANALYTICAL RESULTS Workorder: 1025639 JDTC FIRST 1/2 2015 STORMWATER Lab ID: 1026639002 Date Received: Sample 10: TF-OIL & GREASE-TSS-METALS Date Collected: Parameters Results Units Report Limi DF Prepared Analytical Method: EPA 1664A Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 03/24/2015 9:40 Matrix Aqueous Liquid 03/19/2015 17:38 Sample Type: GRAB By Analyzed By Qual Certifications Hexane Extractable Material <5.00 mg/L 5.00 1 NA NA 3/26/2015 07:15 RTL V Analytical Method: EPA 200.8 — — — _ -- Preparation Method: EPA 200_8 �4 Copper <0.00500 mg/L 0.0050 1 03/27/2015 08:21 JRM 3/30/2015 11:56 HB V Lead <0.00500 mg/L 0,0050 1— 03/27/2015 08:21 JRM 3/30/2015 11:56 HB Y V Zinc Ti 0.0360 mg/L 0.0100 1—03/2712015 08:21 JRM 3/30/2015 11-.56 HB V Analytical Method: SM2540D-2011 Preparation Method: SM2540D-2011 Total Suspended Solids 10.1 mg/L 2.50 1 03/25/2015 16:15 AMW 3/26/2015 14:45 AMW V Report ID: 1025639-20150331163838 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 3 of 4 Analytics Corporation �NAT I CS 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 ANALYTICAL RESULTS Workorder: 1025639 JDTC FIRST 112 2015 STORMWATER Qualifiers Certification Index: V = Virginia (NELAC) - 1 VAC 30-46 W 1, Laboratory ID: 460160, Certificate #: 7668 Report ID: 1025639-20150331163838 Page 4 of 4 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except In full, without the written consent of Analytics Corporation ENVIRONMENTAL CHAIN OF CUSTODY ' I ACCOUNT NAME AND ADDRESS JOH N „EERE TUFF CARE, INC E�5+�1 ��C HIGHWAY 55 EAST FUGUAY—VARINA, NC 275,26 Phone: '319--•567-6449 Fax: 1--91 `3-567-6646 F' RDJ# : 32401015 DATE SHIPPED ]#OFSAMPLES 3� �? �`� PROJECTNAME OR NUMBER 7 _ "r5t , (� `617 �"W4�r I � 10329 Stony Run Lane Ashland, VA 23005 Phone (804) 365-3000 Toll Free (800) 888-8061 Fax (804) 365-3002 PURGHAS ER NO. CONTACT n L4S0 t s �k��,' TELEPHONENtlM3ERt _ RUSH ANALYSIS ❑ Same Day ❑ One Day ❑ Two Day ❑ Three Day Extra Charge E-MAIL ADDRESS: J ;� R � �etr++•�re-. C-or�t - SPECIAL INSTRUCTIONS: D Jul _ 4 ;..�c .aft• - _ �>-: - MATRIX CODES ANALYSIS REQUESTED (Place an °X" in the box below to indicate request) X < m � a U c2 h 41 a V V1 Q j N Preservative Temperat a on Arrival -- RecIce: `, eived on Yes C] No A = AQUEOUS O = OIL a 11 z z 2 M - 4 S = SOLID X = OTHER DW = DRINKING WATER W= WIPES COMMENTS ILab IDI Sample Identification Date &Time PL -0; f +&e_,%se 3�r1i�; : 2Jr A I Z Cr X I f x I PL - T55 3106' 5- 25,p A t Cr X I I IPL- Mc+,%1s 11111s 5-� A l l Cr I x I X X 2 X 1 I x I T55 I3114 l3 5'38,0 1 Cr X n:k 3 19 t3 338,p 1 G- X X X I X I I I I I SAMPLED BY (PRINT NAME):; _ FR I L I P V�E(rAtj' - - ' - - SAMPLED BY (SIG NATURE TO INITIATE;COC)' - W DATE` - - _:_- -6 1-, - TIME -'TIME MP S R C IVED BY: ( GN RE} DATE -TIME_ - CONDITION^ F J SAMPLES RELINQUISHED BY (SIGNATURE) - DATE. TIME . ,=, 4 ' CONDITION Lt L5 IS UV Ots ENVCOC-01 (REV.4120121 ANALYT1CS Work Order. 1025639 Customer Name: JOHN DEERE TURF CARE, INC 32401015 STAND Sample Container Receipt Form Version 6-24-2011 CLIENT SAMPLE iDl LAB CONTAINER IC TYPE OF OTY Temp(C) pH Chlorine on Condition Code Preservative CONTAINER I Arrival (ppm) I PL-OIL & GREASE- 1 1025639001-D 1 1000P 1 1 12 1 2 1 1 OK 1 COOL I ! PL-0IL & GREASE- 1025639001-B 1000G 1 2 ! OK HCL PL-0IL & GREASE- 1025639001-C 1000G 1 2 OK HCL j PL-0IL & GREASE- 1025639001-A 500P j 1 2 2 j 1 OK , HNO3 TF-OIL & GREASE- 1025639002-B 1000G 1 2 F j OK HCL TF-0IL & GREASE- 1025639002-1) 1 1000P 1 1 12 12 1 OK 4 COOL TF-01L & GREASE- 1025639002-A 1 500P 1 1 12 12 1 OK HNO3 I TF-0IL & GREASE- ( 1025639002-C— 11000G 11 12 1 1 1 OK I HCL 1 pie Custodian Signature Version 11-13-2011 CML Page 1 of 1 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 ' Date submitted 11/3/2014 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Philip Keegan LABORATORY Analyttics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow and sent to the Analytics Corporation. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2014 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly'_ (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flaw ❑Water Supply ❑SA ®Other Black Creek, a class C; NSW NOV eE0 5 Z014 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 owR �Lrjo s N No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, IncheS3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks =__> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 6 10/14/2014 1.57 26 mg/L 7.10 <0.005 mg/L <0.005 mg/L 0.0362 mg/L <5.00 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 'For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." 2,0S Pau �IT-,>_ 1,-Ox Name (Print name) Title (Print title 3 ��k (Signature) Da e) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note. If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 1, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?Z Outfall No. Date Sample Collected" (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (5GT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part 8 * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 . _ . Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results or at end of monitoring eriod in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) l 13 / w__ (Da e) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Ljl� Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted U1.3/2014 _ CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Philip Keegan LABORATORY_Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow and sent to the Analytics Corporation. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2014 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly) (month) DISCHARGING TO CLASS ❑ORW ❑HQW [-]Trout ❑PNA ❑Zero -flow ❑Water Supply [-]SA ®Other _Black Creek, a class C; NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?z Outfall No. Date Sample Collected) (mo/dd/yr) 24-hour rainfall amount, Inches3I Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/ Total Petroleum Hydrocarbons Total Toxic Organics Benchmarks =__> - - 100 mg/L or 50 mg/L 6.0 - 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 2 10/14/2014 1.57 12.6 mg/L 6.30 <0.005 mg/L <0.005 mg/L 0.0136 mg/L 6.2 mg/L 3. Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Rcj Auk. KD Name (Print name) �P ui L)" ace A&e-r— Title Print title) a 131 i (5ignat re) ( ate) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier1, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 5WU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS, SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALI_ TRIGGER TIER 2 REQUIREMENTS, SEE PERMIT PART 11 SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports within 30 days of receipt of the lab results (or at end of monitoring geriod in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signs ure of Permittee) l� b3l I (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 '; - Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 11/3/2014 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME Jahn Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Philip Keegan LABORATORY_Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: _ Samples collected at first flow Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2014 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ®Other Black Creek, a class C; NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks ===> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 3 (WB) 10/14/2014 1.57 7.8 6.60 <0.005 <0.005 0.0251 <5.00 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469,31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/2S/2012 Page 1 of 3 -s, Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or Stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." RMAL4 Name (Print name) Title (Print title) (Signat re) n13jI (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, the must be reported in the format "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period ?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 -A Note: !f you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR including off "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to. - Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I a,avAge that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) fl,-, I 14 (Da e) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3of3 Semi-annual Stormwater Discharge Monitories Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 11/3/2014 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Philip Keegan LABORATORY Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2014 SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply [:]SA ®Other_Black Creels, a class C; NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3i Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks =__> _ - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 4 (PL) 10/14/2014 1.57 10.8 7.39 <0.005 <0.005 0.0132 6.3 ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469,22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." �I,bs P Uk s,�D �_Cjy- Name (Print name) (Print title) (Signature) (Oat ) !Vote: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. [] No discharge this period?2 Outfall No. pate Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part IB * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy_ of this DMR including all "No Discharge" reports, within 30 days of receipt of the lob results (or at end of monitoring period in the case of_"No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) 0f (Date) Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 JOHN DEERE TURF CARE 6501 S NC 55 Hwy, FUQUAY-VARINA, NORTH CAROLINA 27526; TFL, (919)567-6400 FAX (919) 567-6648 a JOHN DEERE November 3, 2014 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 Re: 2014 NPDES Storm Water Analytical Report 2"d Half 2014 John Deere Turf Care 6501 S NC 55 Hwy Fuquay-Varina, NC 27526 Permit # NCG030000 CoC # NCG030423 Records: Enclosed is the storm water testing report for our facility for the second half of 2014. On October 14, 2014 samples were collected from all the discharge outfalls. Samples were collected by John Deere Turf Care Employee Philip Keegan. Both SDO samples were sent to Analytics Corporation — 10329 Stony Run Lane, Ashland VA, 23005 for analysis. The samples were analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with an Oakton pHTestr30 on -site immediately after samples were retrieved. The results are shown on form SWU 245. Analytical data was received from Analytics Corporation on October 27, 2014. If you have any questions or comments, please contact me at (919) 285-0338 at your convenience. Sincerely, Philip Keegan — Environmental Engineer John Deere Turf Care t70 LA N A W Tlf" -S October 27. 2014 PHILIP KEEGAN JOHN DEERE TURF CARE, INC 5501 NC HIGHWAY 55 EAST Fuquay Varina, NC 27526 Account ID: 32401015 STANDARD Purchase Order: 4501302764 Client ID: STORM WATER 10-14-2014 Work Order: 1023511 Dear PHILIP KEEGAN Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Enclosed are the analytical results for sample(s) received by the laboratory on Thursday, October 16, 2014. The signature below certifies that the results are based on the referenced methods and applicable certifications or accreditations are noted for each parameter reported (see key at end of report), Unless otherwise specified all analyses of solid materials are based on dry weight. Reported results relate only to the items tested, as received by the laboratory. On -site analysis (analysis ASAP) is recommended for the following tests: pH, temperature, dissolved oxygen, residual chlorine and sulfite. When performed off -site, these tests do not meet NELAC standards. Abbreviations:ug/L = micrograms per Liter, mg1L = milligrams per Liter, ug/g = micrograms per gram, mg/kg = milligrams per kilogram ugtwp = micrograms per wipe, ug/ml = micrograms per millimeter, uS/cm = microsiemens per centimeter at 25 degrees Celcius ppb = parts per billion, DF = Dilution Factor. If you have any questions concerning this report; please feel free to call Client Services at 1-800-888-8061. Sincerely, nnpp' Dawn,Ca to Technical Director (or designee) Enclosures ReportID: 1023511-20141027154343 CERTIFICATE OF ANALYSIS Page 1 of 4 This report shall not be reproduced, except in full, without the written consent of Analytics Corporation .t �cNALYTICS ANALYTICAL RESULTS Workorder: 1023511 STORM WATER 10-14-2014 Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Lab ID: 1023511001 Date Received: 10/16/2014 10:00 Matrix Aqueous Liquid Sample ID: TF Date Collected: 10/14/2014 11:10 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications Analytical Method: EPA 1664A Hexane Extractable Material 6.20 mg/L 5.00 1 NA NA 10/23/2014 18:04 SH V Analytical Method: EPA 200.8 Preparation Method: EPA 200.8 Copper <0.00500 mg1L 0.0050 1 10120/2014 08:40 JRM 10/20/2014 17:34 HB V Lead <0.00500 mg1L 0.0050 1 10/20/2014 08:40 JRM 10120/2014 17:34 HB V Zinc 0.0136 mg1L 0.0100 1 10/20/2014 08:40 JRM -10/2012014 17:34 HB V Analytical Method: SM2540D-2011 Preparation Method: SM2540D-2011 Total Suspended Solids 12.6 mg1L 2.50 1 Report10: 1023511-20141027154343 10/20/2014 17:15 AMW 10/21/2014 11:15 AMW V CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 2 of 4 Analytics Corporation 0ALA NALYT11"S 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 ANALYTICAL RESULTS Workorder: 1023511 STORM WATER 10-14-2014 Lab ID: 1023511002 Date Received: 10/16/2014 10:00 Matrix Aqueous Liquid Sample ID: PL Date Collected: 10/14/2014 15:20 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications Analytical Method: EPA 1664A Hexane Extractable Material 6.30 mg1L 5.00 1 NA NA 10/23/2014 18:04 SH V Analytical Method: EPA 200.8 Preparation Method: EPA 200.8 Copper <0.00500 mg1L 0.0050 1 10/20/2014 08:40 JRM 10/20/2014 17:48 HS V Lead <0.00500 mg/L 0.0050 1 '1012012014 08:40 JRM 10/20/2014 17:48 HB V Zinc 0.0132 mg/L 0.0100 1 10/20/2014 08A0 JRM 10/20/2014 17:48 HB V Analytical Method: SM254OD-2011 Preparation Method: SM254OD-2011 Total Suspended Solids 10.8 mg/L 2.50 1 10/20/2014 17:15 AMW 10/21/2014 11:15 AMW V Report10: 1023511-20141027154343 CERTIFICATE OF ANALYSIS Page 3 of 4 This report shall not be reproduced, except in full, without the written consent of Analytics Corporation L-A:NALYTF pp -CS Workorder: 1023511 Qualifiers Certification Index: STORM WATER 10-14-2014 ANALYTICAL RESULTS V = Virginia (NELAC) - 1 VAC 30-46 H 1, Laboratory ID: 460160, Certificate #: 2868 Report ID: 1023511-20141027154343 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Page 4 of 4 ENVIRONRAENTAL CHAIN OF CUSTODY DATE SHIPPED— - # OF SAMPLES" PROJECT'NAME'OR'NU_MBER ACCOUNT NAME AND ADDRESS0.���,� r r JOHN DEERE TURF CARE, INC PURCHASE ORDER NO:. CONTACT ; Tl � rHONE NUMBER: ' ���� �� � ,� � 6501 IVG HIGHWAY 5,� EAST - RUSH E-MAIL ADDRESS: z r FUQUAY--VF�RINAr NC E75r26 10329 Stony Run Lane 1 Phone: 919-57-6449 a r .�. D +% e.Cbr"- '!�,'f ��AI� c6a Ashland, VA 23005 F,-Ax : 1-919—b67•--6648 ❑ Same Day ❑ One Day _ _ ! . Phone (804) 365 3000 SPECIAL=INSTRUCTIONS: PR.9 i# : 3"0401015 ❑ Two Day Toll Free (800) 888-8061 ❑ Three Day - Fax (804) 365-3002 Extra Charge „ _._ - -- -- nnaTRlx CODES - .. ANALYSIS REQUESTED (Place an. "X jn the -box below to indicate request) °—�' o 1 j - (% E Preservative Temperpure.on Arrival _ e nLice:es•❑ No R ceived a A = AouEbus _ o = ol� S = SOLID X -OTHER X a m o 4 �.- ,-rl V] `• �' = L - — DW = DRINKING WATER W = WIPES . - s �ab ID Sample Identification Date & Time 5 Ca k ILL -: toy 1�1I�_i�•IDA Ain _ r-Ws - - - - , I _17 I f BY (PRNT NAME t t TINISAMPLED SAMPED,B 11AOTIATEiC 4 D 3 TIME A ` LES_REC vED (SIGN' } DATE ' > `: "TIME L. CONDlTI �.., SAMPLES RELINQUISHED BY (SIGNATURE) -- DATE - TIME CONDITIQN — -' ENVCOC-01 {REV. A12012) NA TICS Work Order: '1023511 Customer Name: JOHN DEERE TURF CARE, INC 32401015 STAND Sample Container Receipt Form Version 6-24-2011 CLIENT SAMPLE ID LAS CONTAINER ID TYPE OF CONTAINER QTY Temp(C) pH Chlorine on Arrival (ppm) Condition Code Preservative TF ,,1023511001-A 50013 1 12 j 8 1 OK NONE j TF 11023511 001-D 1000P j 1 12 1.8 OK j COOL j TF j 1023511001-C j 1000G j 1 12 j j j OK I HCL j j TF ' 1023511001-13 j 1000G j 1 12 j j _ j OK HCL PL �,1023511002-C f_1000G j 1 2 j j j OK _ j HGL PL - j,1023511002-D j 1000P € 1 j 2 j 8 j E,OK j COOL [ PL- j'1023511002-B j-1000G 1-1- 12 j j OK HCL m j-PC j 1023511002-A j 500P j 1- 2 8 OK NONE Notes - -n Sample Custodian Signa re I Date: - . t0H-AAo-rAn:YN--- Ant-� Version 11-13-2011 CML Page 1 of 1 /J�►NALYTICS October 27, 2014 PHILIP KEEGAN JOHN DEERE TURF CARE, INC 5501 NC HIGHWAY 55 EAST Fuquay Varina, NC 27526 Account ID: 32401015 STANDARD Purchase Order: 4501302764 Client ID: STORM WATER 10-14-2014 Work Order: 1023512 Dear PHILIP KEEGAN Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Enclosed are the analytical results for sample(s) received by the laboratory on Thursday, October 16, 2014. The signature below certifies that the results are based on the referenced methods and applicable certifications or accreditations are noted for each parameter reported (see key at end of report). Unless otherwise specified all analyses of solid materials are based on dry weight. Reported results relate only to the items tested, as received by the laboratory On -site analysis (analysis ASAP) is recommended for the following tests: pH, temperature, dissolved oxygen, residual chlorine and sulfite. When performed off -site, these tests do not meet NELAC standards. Abbreviations:ug/L = micrograms per Liter, mg/L = milligrams per Liter, ug/g = micrograms per gram, mglkg = milligrams per kilogram ug/wp = micrograms per wipe, ug/ml = micrograms per millimeter, uSlcm = microsiemens per centimeter at 25 degrees Celcius ppb = parts per billion, DF = Dilution Factor. If you have any questions concerning this report, please feel free to call Client Services at 1-800-888-8061. Sincerely; LU Dawn C to Technical Director (or designee) Enclosures Report ID: 1023512-20141027154343 CERTIFICATE OF ANALYSIS Page 1 of 4 This report shall not be reproduced, except in full, without the written consent of Analytics Corporatlon ,60LANALYTICS ANALYTICAL RESULTS Workorder: 1023512 STORM WATER 10-14-2014 Lab ID: 1023612001 Date Received Sample ID: BY Date Collected Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 10/16/2014 10:00 Matrix Aqueous Liquid 10/14/2014 11:00 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications Analytical Method: EPA 1664A Hexane Extractable Material <5.00 mg/L 5.00 1 NA NA 10123/2014 18:04 SH V Analytical Method: EPA 200.8 Preparation Method: EPA 200.8 Copper <0.00500 mg1L 0.0050 1 10/20/2014 08:40 JRM 10/20/2014 17:52 HB V Lead— <0.00500 mg/L 0.0050 1 10/20/2014 08:40 JRM 10/20/2014 17:52 HB V Zinc 0.0362 mglL 0.0100 1 10/20/2014 08:40 JRM' 10/20/2014 17:52 HB V Analytical Method: SM2540D-2011 Preparation Method: SM2544D-2011 Total Suspended Solids 26.0 mg/L 2.50 1 10/20/2014 17:15 AMW 10/21/2014 11:15 AMW V ReportID: 1023512-20141027154343 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except In full, without the written consent of Analytics Corporation Page 2 of 4 ALYTICS ANALYTICAL RESULTS Workorder: 1023512 STORM WATER 10-14-2014 Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Lab 10: 1023512002 Date Received. 10/16/2014 %00 Matrix Aqueous Liquid Sample ID: WB Date Collected:, 10/14/2014 11:05 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications Analytical Method: EPA 1664A 111 Hexane Extractable Material <5.00 mg/L 5.00 1 NA NA 10/23/2014 18:04 SH V Analytical Method: EPA 200.8 Preparation Method: EPA 200.8 Copper <0.00500 mg/L 0.0050 1 10/20/2014 08:40 JRM 10/20/2014 18:11 HB V Lead <0.00500 mg1L 0.0050 1 10/20/2014 08:40 JRM 10/20/2014 18:11 HS V Zinc 0.0251 mg/L 0.0100 1 10/20/2014 08:40 JRM 10/20/2014 18:11 HB V Analytical Method: SM2540D-2011 Preparation Method: SM2540D-2011 Total Suspended Solids 7.80 mg/L 2.50 1 10/20/2014 17:15 AMW 10/21/2014 11:15 AMW V Report ID: 1023512-20141027154343 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 3 of 4 Analytics Corporation A NALYTICS 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 ANALYTICAL RESULTS Workorder: 1023512 STORM WATER 10-14-2014 Qualifiers Certification Index: V = Virginia (NELAC) - 1 VAC 30-46 H 1, Laboratory 10: 4601160, Certificate #: 2868 ReportID: 1023512-20141027154343 CERTIFICATE OF ANALYSIS Page 4 of 4 This report shall not be reproduced, except in full, without the written consent of Analocs Corporation ENVIRONMENTAL CHAIN OF CUSTODY DATESHIPPED— # OF SAMPLES " PROJECT NA�M_E1'OR'NUMBER ACCOU T.NAMEANUADDRESS l 1_01 If I Iq_ _ A� IT � CIS PURCHASE ORDER NO. -" __ CONTACT -' "" - - TELEPHONE NUMBER 4 Rt 2g5 o3v -� -� . _ 10329 Stony Run Lane Ashland, VA 23005 RUSH -, ANALYSIS G� E-MAILADDRESS: _ -� ' . ' C,b�L ❑ Same Day ❑ One Day Phone (804) 365-3000 SPECIAL INST CTIONS_ : - © Two nay _ Toll Free (800)!888-8061 ��` R Q ❑ Three Day - Fax. (804) 365-3002 Extra Charge C HA 'A`TVVV� Y?,` MATRIX CODES` "" ANALYSIS REQUESTED (Place an "X`in the b0xjbelow,'to_indicate- -request) 3 'Preservative TeBr6ratureonAnival A=AQUEOUS , O=OIL x ' m or — t - t rr !, -� : `' C1, �' M. V Received e:;❑Yes No S = SOLID - X = OTHER DW = DRINKING WATER W = WIPES - - COMMENTS Lab ID Sample identification Date & Time _ x z, .o_ io cK OU 11801 2 X J D.V We T 5 - - o l-q lr-gA A - h .CT : z- WlA-�5 to ! I" 11 -05 - -= Cr X F -, - - - jr- �1 _ -- - - - - _ SAMPLED {PRINT NAME1 = " • .-: SAMPL Y iSkGN URETQ ENITIATk icoc).T _ `"t r'; Aft TIME20,0 [14., "__ _ - SAMPLES RECEIVEDBY: x � - �'`— "TIME � ,; ; ,.., ... SAMPLES,RELINQUISHED BY - ` i y^ i (SIGNATURE} ,- ATE - CONDITION (SIGNATURO DATE * TIME CONDITION "VHAMG E z a — ENVCOC-01 (REV.4l2012) ANALYTICS Work Order: 1023512 Customer Name: JOHN DEERE TURF CARE, INC 32401015 STAND Sample Container Receipt Form Version 6-24-2011 CLIENT SAMPLE ID LAB CONTAINER ID TYPE OF CONTAINER CITY Temp(C) pH Chlorine on Arrival (ppm) Condition Code Preservative BY 1023512001-C I 100OG - 1 - 2- 1 j'OK - - - -I-HCL BY - -1023512001 A 1 500P 1 12 8 1 I OK I COOL BY 1023512001-D 11000P 1 12 1$ I I OK I GOAL 1 BY 1.1023512001-B I1000G I1 12 1 I IOK HCL I' WB I 1023512002-D 11004p 11 12 8 1 I OK COOL WB I 1023512002-A 500P 11 12 18 1 I OK COOL 1 WB}' 1023512002=6 11000G 11` 12 1 OK HCL WB I 11004G 1 12 1 OK HCL Notes r1023512-C- lion 11-13-2011 CML Page 1 of 1 .) Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 4/28/2014 CERTIFICATE OF COVERAGE NO. NCG030423 R9� /� SAMPLE COLLECTION YEAR 2014 FACILITY NAME John Deere Turf Care _ 11 �i SAMPLE PERIOD ® Jan -June ❑ July -Dec COUNTY Wake APR 3 0 2014 or ❑ Monthly' lmonth] PERSON COLLECTING SAMPLES _Philip Keegan DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA LABORATORY Analytics Corporation. Lab Cert. # 459 CENTRAL FILES ❑Zero -flow ❑Water Supply ❑SA Comments on sample collection or analysis: Samples collected at first DWQIBOG ®Other Black Creek, a class C; NSW flow and sent to the Analytics Corporation. - PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 Part A: Stormwater Benchmarks and Monitoring Results ❑ No discharge this period:2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics genchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L IS mg/L i mg/L SDO 2 T F 04/15/2014 1.78 7.60 mg/L 6.95 <0.005 mg/L <0.005 mg/L 0.0281 mg/L 7 mg/L 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 A Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." �"A L_( ND :FOX Name (Print name) �F2GEbY � Title (Print ti e) O ( ign re) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX me/L where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. !Vote: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier Z or Tier 3 responses. See General Permit text Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 . Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 1, or Tier 3 responses. See General Permit text. FOR PART AAND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an on inal and one copy of this DMR including all "No Discharge" re arts within 30 days of recei t of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27644-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are signifipant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) 429114 (date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 4/28/2014 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Philip Keegan LABORATORY_Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: -Samples collected at first flow and sent to the Analytics Corporation. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2014 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly'(month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ®Other Black Creek a class C• NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period: outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic 0rganics5 Benchmarks =__> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 6 BY 04/15/2014 1.78 4.30 mg/L 6.92 <0.005 mg/L <0.005 mg/L 0.0476 mg/L 5.90 mg/L ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 4* - Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." �A-LI mP F�4 Name (Print name) Ti tint title) 4-IaZli (Signature) jDatel Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format. "<XX me/L". where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note. !f you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. No discharge this period?z Outfall No. Date Sample Collected" (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 'r Note. If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMIi, including all "No Discharge" reports within 30 days of receipt of the lab results (or at end of monitoring period in the case o "No Discharge" re orts)to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am pie e that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signaturd of Permittee) `"C l ` - (D te) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 JOHN DEERE TURF CARE 6501 S NC 55 Hwy, FUQUAY-VARINA NORTH CAROLINA 27526; TEL (919)567-6440 FAX (919) 567-6649 U-0-4; --*, April 28, 2014 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 Re: 2014 NPDES Storm Water Analytical Report I" Half 2014 John Deere Turf Care 6501 S NC 55 Hwy Fuquay-Varina, NC 27526 Permit # NCG030000 CoC # NCG030423 Records: Enclosed is the storm water testing report for our facility for the first half of 2014. On April 15, 2014 samples were collected from the remaining outfalls out of our four storm water discharge outfalls. Samples were collected by John Deere Turf Care Employee Philip Keegan. Both SDO samples were sent to Analytics Corporation — 10329 Stony Run Lane, Ashland VA, 23005 for analysis. The samples were analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc. pH readings were taken with an Oakton pHTestr30 on - site immediately after samples were retrieved. The results are shown on form SWU 245, This report includes analytical results from SDO#2 and SDO#6 of our storm water outfalls. Analytical data was received from Analytics Corporation on April 25', 2014. If you have any questions or comments, please contact me at (919) 285-0338 at your convenience. Sincerely, Philip Keegan — Environmental Engineer John Deere Turf Care ,#YANALYTICS April 26, 2014 PHILIP KEEGAN JOHN DEERE TURF CARE, ING 5601 NC HIGHWAY 55 EAST Fuquay Varina, NC 27526 Purchase Order: Client ID: STORMWATER 4-15-2014 Work Order: 1020546 Dear PHILIP KEEGAN Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Enclosed are the analytical results for sample(s) received by the laboratory on Wednesday, April 16, 2014. The signature below certifies that the results are based on the referenced methods and applicable certifications or accreditation$ are noted for each parameter reported (see key at end of report). Unless otherwise specified all analyses of solid materials are based on dry weight. Reported results relate only to the items tested, as received by the laboratory. On -site analysis (analysis ASAP) is recommended for the following tests: pH, temperature, dissolved oxygen, residual chlorine and sulfite. When performed off -site, these tests do not meet NELAC standards. Abbreviations:ugfL = micrograms per Liter, mg/L = milligrams per Liter, uglg = micrograms per gram, mgtkg = milligrams per kilogram uglwp = micrograms per wipe, uglml = micrograms per millimeter, uSlcm = microsiemens per centimeter at 25 degrees Celcius ppb =parts per billion, DF = Dilution Factor. If you have any questions concerning this report, please feel free to call Client Services at 1-800-888-8061. Sincere) Q Dawn Technical Director (or designee) Enclosures Report ID; 1020546-20140425173434 CERTIFICATE OF ANALYSIS Page 1 of 8 This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Analytics Corporation0006t MALYTOCS 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 ANALYTICAL RESULTS Workorder: 1020546 STORMWATER 4-15-2014 Lab ID: 1020546001 Date Received: Sample ID: TF OIL $ GREASE Date Collected: Parameters Results units Report Lim! DF Prepared 0. D411612014 10:55 Matrix Aqueous Liquid 04/15/2014 8:00 Sample Type: GRAB By Analyzed By Qual Certifications Analytical Method: EPA 1664A Hexane Extractable Material 7.00 mglL 5.00 1 NA NA 4/23/2014 15:38 RTL V ReportID: 1020546-20140425173434 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 2 of 8. , ,pOLANALYT'cs ANALYTICAL RESULTS Workorder: 1020546 STORMWATER 4-15-2014 Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Lab ID: 1020546002 Date Received: 04/16/2014 10:55 Matrix Aqueous Liquid Sample ID: TF TSS Date Collected: 04/15/2014 8:00 Sample Type; GRAB Parameters Results Units Report Liml DF Prepared By Analyzed By Qual Certifications Analytical Method: SM25400-2011 Preparation Method: SM2540D-2011 - T Total Suspended Solids 7.60 mg/L 2.50 1 04/21/2014 17:00 TTW 4/23/2014 11:05 TTW V Report 10: 1020546-20140425173434 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except In full, without the written consent of Analytics Corporation Page 3 of 8 Analytics Corporation aNALYTICS 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 ANALYTICAL RESULTS Workorder. 1020546 STORMWATER 4-15-2014 Lab ID: 1020546003 Date Received: 04/16/2014 10:55 Matrix Aqueous Liquid Sample ID: TF METALS Date Collected: 04/15/2014 8:00 Sample Type: GRAB Parameters Results Units Report Urni OF Prepared By Analyzed By Qual Certifications k Analytical Method: EPA 200.8 Preparation Method: EPA 200.8 Copper <0.00500 mg1L 0.0050 1 04/22/2014 08:46 JRM 4/22/2014 22:10 HB V Lead <0.00500 mg1L 0,0050 1 04/22/2014 68:46 JRM. 4/22/2014 22:10 HB V Zinc 0.0281 mg/L 0.0100 1 04/22/2014 08:46 JRM 4/23/2014 15:13 HB V Report ID: 1020546-20140425173434 CERTIFICATE of ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 4 of 8_ ,eLANALYTICar ANALYTICAL RESULTS Workorder: 1020546 STORMWATER 4-15-2014 Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Lab ID: 1020546004 Hate Received: 04/16/2014 10:55 Matrix Aqueous Liquid Sample ID: BY OIL & GREASE Date Collected: 0411512014 8:10 Sample Type: GRAB Parameters Results Units Report Lim! DF Prepared By Analyzed By Qual Certifications Analytical Method: EPA 1664A Hexane Extractable Material 5.90 mglL 5.00 1 NA NA 4/23/2014 15:38 RTL V Report ID: 1020546-20140425173434 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytim Corporation Page 5 of 8 Analytics Corporation ,,,A/ANALY '. CSff 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 ANALYTICAL RESULTS Workorder: 1020546 STORMWATER 4-15-2014 Lab ID: 1020646005 Date Received: Sample ID: BY TSS Date Collected: 04/16/2014 10:55 Matrix Aqueous Liquid 04/15/2014 8:10 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications Analytical Method: SM2540D-2011 Preparation Method: SM2540D-2011 Total Suspended Solids 4,30 mg/L 2.50 1 04/21/2014 17:00 TTW 4/23/2014 11:05 TTW V Report ID: 1020646-20140425173434 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 6 of 8„ . i ,..*LA NALYTIrvm-S ANALYTICAL RESULTS Workorder: 1020546 STORMWATER 4-15-2014 Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone; (804) 365-3000 Fax: (908) 365-3002 Lab ID: 1020646006 Date Received; 04/16/2014 10:55 Matrix Aqueous Liquid Sample 10: BY METALS Date Collected: 04/1512014 8:10 Sample Type: GRAB Parameters Results Units Report Liml DF Prepared By Analyzed By Qual Certifications Analytical Method: EPA 200.8 Preparation Method: EPA 200.8 Copper <0.00500 mg/L 0.0050 1 04/22/2014 08:46 JRM 4/22/2014 22:10 HB V Lead <0,00500 mg/L 0.0050 1 04/22/2014 08:46 JRM 4/22/2014 22:10 HB V Zinc 0.0476 mg/L 0.0100 1 04/22/2014 08:46 JRM 4/23/2014 1517 HB V Report 10: 102t:2546-20140425173434 CERTIFICATE OF ANALYSIS This report Shall not be reproduced, except in full, without the written consent of Ane"cs Corporation Page 7 of 8 Analytics Corporation ` N A W TICS 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 . Fax: (908) 365-3002 ANALYTICAL RESULTS Workorder: 1020546 STORMWATER 4-15-2014 Batch Qualifiers Batch: eEXT-2495 Insufficient sample volume available for matrix spike and duplicate analysis as per EPA 1664A. Qualifiers Certification Index: V = Virginia (NELAC) - 1 VAC 30-46 H 1, Laboratory ID: 460160, Certificate #: 2770 ReportID: 1020546-20140425173434 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except In full, without the written consent of Analytics Corporation Page 8 of 8, ENVIRONMENTAL CHAIN OF CUSTODY ACCOUNT NAME AND ADDRESS JOHN DP -ERE TURF CARE INC 6501 NC HIGHWAY 55 EAST l=LIG!LIAY--VARiNA. NC c75cI FU n e : 'V R I NA7—NC Fax; 1-919-5E7--E648 R ROJ# : 32401015 DATE SHIPPED # OF SAMPLES PROJECT NAME OR NUMBER 1� 4-I5- 1q1. 8 5t0,^,_Aer '1-167- Z0( i[f r ^�A L 10329 Stony Run Lane Ashland, VA 23005 Phone (804) 365-3000 Toll Free (800) 888-8061 Fax (804) 365-3002 PURCHASE ORDER NO. 5013'7(0qi�i CONTACT TELEPHONE NUMBER RUSH ANALYSIS p Same Day ❑ One Day ❑ Two Day ❑ Three Day Extra Charge E-MAIL ADDRESS: � R, I;P R � �Jr�6u�► �re., CA#"r - SPECIAL INSTRUCTIONS, _ ,.. MATRIX CODES ANALYSIS REQUESTED (Place an "X" in the box below to indicate request) x a g m o a � r ,.Q ff V Preservative Tee eratu ° �,Ih A = AQUEOUS O = OIL a N z" J _ M o 2 M o Received an Ice; � � ElNo S =SOLID X =OTHER DW = DRINKING WATER W= WIPES COMMENTS Lab ID Sample Identification Date & Time -F �qe A G X X F tf Py -1 t- Grp, slaa . 2 CrT 4 55 qlq k � tT fie Prt �` By Meiuk `T'[[4- �X1 11 -I64 A ! ` er X SAMPLED BY (PRINT NAME).. s h �L SAMP ,BY (SIGN TURE-TQ INITIATECOC): - fir ATEy �] TIME IQ&L j SAMPLES RECEIVED BY: (SIGNATURE) DATE TIME CONDITION SAMPLES RELINQUISHED BY. (SIGNATURE) _ DATE TIME CONDITION ------------- ENVCOC-01 (REV 40012; te�L�-NALYTICS Work Order_ 1020546 Customer Name: JOHN DEERE TURF CARE, INC 32401015 STAND Sample Container Receipt Form Version 6=24-2011 CLIENT SAMPLE ID LAB CONTAINER ID TYPE OF CONTAINER J. QTY Temp(C) ;'OH Chlorine on Arrival (ppm) Condition Code Preservative TF OIL & GREASE 1020546601-A f 100OG - 1 �� 4 f OK HCL TF OIL & GREASE 1020546001-B 11000G Ill1 14 i OK� " HCL TF TSS 1020546002-A 1000P 1 ,1 1,4 - OK NONE TF METALS 1020546003-A 1..500>' js T "4 8 ; OK _ { HNO3 BY OIL & GREASE 1020546004-B jA000G '11 1 1 '4 10K HCL BY OIL &GREASE � i0z0546004-A 11000G 1 1 --- 14 � OK _ 4 HCL . BY TSS 1020546005-A 110001' _ 1_1_-_ _ 1—'4 _ "-,1_8 ,__ j I.OK _ COOL _ BY METALS 1020546006-A .500P 1 ._I4 1,2 j; OK HNO3 Notes Custodian Signature ��,r+' ' • Date: - r-- f1t�A� ��• Il Version 11-13-2011 CML Page 1 of 1 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Philip Keegan LABORATORY_Analytics Corporation. Lab Cert. ## 459 Comments on sample collection or analysis: Samples collected at first flow Part A: Stormwater Benchmarks and Monitoring Results 4/17/2014. SAMPLE COLLECTION YEAR 2014 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA RECEIVED ❑Zero -flow ❑Water Supply ❑SA APR 2 1 2014 ®Other Black Creek a class C• NSW - CENTRAL FILES PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 oWQIBOG No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Iota! Total Petroleum Hydrocarbons Toxic Organics Benchmarks ===> - - 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L 500 3 (WB) 04/07/2014 0.36 45.8 7.43 <0.005 <0.005 0.0507 <5.00 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 ''Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General al Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." b�AU (Qn Name (Print name) Title (Print title) (Signa re) (Date; Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier2, or Tier responses. See General Permit text. Part 8: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period? Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> _ - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 ►Note: If yey report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART if SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case o "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significantVnalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) 4N-l. (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 • Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 4/17/2014 CERTIFICATE OF COVERAGE NO. NCG030423 FACILITY NAME John Deere Turf Care COUNTY Wake PERSON COLLECTING SAMPLES _Philip Keegan LABORATORY Analytics Corporation. Lab Cert. # 459 Comments on sample collection or analysis: Samples collected at first flow. Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2014 SAMPLE PERIOD ® Jan -June ❑ July -Dec or ❑ monthly' month DISCHARGING TO CLASS ❑ORW ❑HCtW ❑Trout ❑PNA []Zero -flow ❑Water Supply [:]SA ®Other Black Creek, a class C; NSW PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this period?2 Outfall No. Date Sample Collected" (mo/dd/yr) 24-hour rainfall amount, Inches3 Total Suspended Solids pH, Standard units Copper Lead Zinc Non -Polar O&G/Total Total Petroleum Hydrocarbons Toxic Organics Benchmarks 100 mg/L or 50 mg/L 6.0 — 9.0 0.007 mg/L 0.033 mg/L 0.067 mg/L 15 mg/L 1 mg/L SDO 4 (PL) 04/07/2014 0.36 33.9 7.50 <0.005 <0.005 0.0323 <5.00 1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 2 For sampling periods with no discharge at any single outfali, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ° See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." 4?4ks- Name (Print name) Title (Print title) (Sign)*ure) (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mXIL", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. ❑ No discharge this period?z Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table S, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 A '"Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "'No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permittee) 4 (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 JOHN DEERE TURF CARE 6501 S NC 55 Hwy, FUQUAY-VARINA, NORTH CAROLINA 27526; TEL (919)567-6400 FAX (919) 567-6648 JOHN DEERE April 17, 2014 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 Re: 2014 NPDES Storm Water Analytical Report I" Half 2014 John Deere Turf Care 6501 S NC 55 Hwy Fuquay-Varina, NC 27526 Permit # NCG030000 CoC # NCG030423 Records: Enclosed is the storm water testing report for our facility for the first half of 2014. On April 7, 2014 samples were collected from two of our four storm water discharge outfalls. Samples were collected by John Deere Turf Care Employee Philip Keegan. Both SDO samples were sent to Analytics Corporation — 10329 Stony Run Lane, Ashland VA, 23005 for analysis. The samples were analyzed for TSS, Oil & Grease, Lead, Copper, and Zinc, pH readings were taken with an Oakton pHTestr30 on -site immediately after samples were retrieved. The results are shown on form SWU 245. This report includes analytical results from SDO#3 and SDO#4 of our storm water outfalls. Analytical data was received from Analytics Corporation on April 16'", 2014. If you have any questions or comments, please contact me at (919) 285-0338 at your convenience. Sincerely, Philip Keegan — Environmental Engineer John Deere Turf Care /fi�Ne4LYTICS April 16, 2014 PHILIP KEEGAN JOHN DEERE TURF CARE, INC 5501 NC HIGHWAY 55 EAST Fuquay Varina, NC 27526 Purchase Order: Client ID'. STORMWATER 4-7-2014 Work Order: 1020439 Dear PHILIP KEEGAN Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Enclosed are the analytical results for sample(s) received by the laboratory on Wednesday, April 09, 2014. The signature below certifies that the results are based on the referenced methods and applicable certifications or accreditations are noted for each parameter reported (see key at end of report). Unless otherwise specified all analyses of solid materials are based on dry weight. Reported results relate only to the items tested, as received by the laboratory. On -site analysis (analysis ASAP) is recommended for the following tests: pH, temperature, dissolved oxygen, residual chlorine and sulfite. When performed off -site, these tests do not meet NELAC standards. Abbreviations:ug/L a micrograms per Liter, mg/L - milligrams per Liter, uglg - micrograms per gram, mgfkg = milligrams per kilogram uglwp = micrograms per wipe, uglml = micrograms per millimeter, uS/cm = microsiemens per centimeter at 25 degrees Celcius ppb = parts per billion, DF = Dilution Factor, If you have any questions concerning this report, please feel free to call Client Services at 1-800-886-8061. Sincerely 0 Dawn s Technical Director (or designee) Enclosures ReportID: 1020439-20140416091616 CERTIFICATE OF ANALYSIS Page 1 of 8 This report shall not be reproduced, except in full, without the written consent of Analytics Corporation LANAWTINCS ANALYTICAL RESULTS Workorder: 1020439 STORMWATER 4-7-2014 Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Lab 10: 1020439001 Date Received: 04/09/2014 10:00 Matrix Aqueous Liquid Sample ID: WB OIL & GREASE Date Collected: 04/07/2014 14:00 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications Analytical Method: EPA 1664A Hexane Extractable Material <5.00 mglL 5.00 1 NA NA 4/15/2014 15:11 RTL V Report ID: 1020439-20140416091616 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Ana"cs Corporation Page 2 of 8 ANALYTICS ANALYTICAL RESULTS Workorder. 1020439 STORMWATER 4-7-2014 Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Lab ID: 1020439002 Date Received: 04/09/2014 10:00 Matrix Aqueous Liquid Sample ID: WB TSS Date Collected: 04/07/2014 14:00 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications Analytical Method: SM2540D-2011 Preparation Method: SM2540D-2011 Total Suspended Solids 45.8 mg/L 2.50 1 04/14/2014 13:35 TTW 4/15/2014 12:00 TTW V Report ID: 1020439-20140416091616 CERTIFICATE OF ANALYSIS This report shell not be reproduced, except In fall; without the written consent of Analytics Corporation Page 3 of 8 f. j0fAHAWTlr'CS ANALYTICAL RESULTS Workorder: 1020439 STORMWATER 4-7-2014 Analytics Corporation 10329 Stony Run Lane.. Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 Lab ID: Sample ID: 1020439003 WB METALS Date Received: Date Collected: 04/09/2014 10:00 Matrix Aqueous Liquid 04/07/2014 14:00 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications Analytical Method: EPA 200.8 Preparation Method: EPA 200.8 Copper <0.00500 mg/L 0.0050 1 04/10/2014 08:18 JRM 4/10/2014 15:30 HB V Lead <0.00500 mg/L 0.0050 1 04/10/2014 08J8 JRM 4/10/2014 15:30 HB V Zinc 0.0507 mg/L 0.0100 1 04/10/2014 08:18 JRM 4/10/2014 1530 HB V Report ID, 1020439-20140416091616 CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation Page 4 of 8 '- ANALYTICS ANALYTICAL RESULTS Workorder: 1020439 STORMWATER 4-7-2014 Lab ID: 1020439004 Date Received: Sample ID: PL OIL & GREASE bate Collected: -Analytics Corporation 10329 Stony Run Lame Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 04/09/2014 10:00 Matrix Aqueous Liquid 04/07/2014 13:50 Sample Type: GRAB Parameters Results Units Report Lim] DF Prepared By Analyzed By Qual Certifications Analytical Method: EPA 1664A Hexane Extractable Material <5.00 mg/L 5.00 1 NA NA 4/15/2014 15:11 RTL V Report ID:. 1020439-201404160gfM6 CERTIFICATE OF ANALYSIS This repot shall not be reproduced, except in full, without the written consent of Analytics Corporation a 0 Page 5 of 8 AW T ,*LANCS Anal Stony Corporation 10329 Stony Run Lane. Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 ANALYTICAL RESULTS Workorder: 1020439 STORMWATER 4-7-2014 Lab ID: 1020439006 Date Received: 04/09/2014 10:00 Matrix Aqueous Liquid Sample ID: PL TSS Date Collected:. 04/07/2014 13:50 Sample Type: GRAB Parameters Results Units Report Limi DF Prepared By Analyzed By Qual Certifications Analytical Method: SM2540D-2011 Preparation Method: SM2540D-2011 Total Suspended Solids 33.9 mg& 2.50 1 04/14/2014 13:35 TTW 4/15/2014 12:00 TTW V Report ID: 1020439-20140416091616 CERTIFICATE OF ANALYSIS This report shall not be reproduced; except in full. without the written consent of Ana Vics Corporatlan W1 Page 6 of 8 -+ 1 ANALYTICCS ANALYTICAL RESULTS Analytl6s Corporation 10329 Stony Run Lane Ashland, VA 23005 Rhone: (804) 365-3000 Fax: (908) 365-3002 Workorder: 1020439 STORMWATER 4-7-2014 Lab ID: 1020439006 Date Received: 04/09/2014 10:00 Matrix Aqueous Liquid Sample ID: PL METALS Date Collected: 04/07/2014 13:50 Sample Type: GRAB Parameters Results Units Report Lim! DF Prepared By Analyzed By Quai Certifications Analytical Method: EPA 200.8 Preparation Method: EPA 200.8 Copper <0.00500 mg1L 0.0050 1 04/10/2014 08:18 JRM 4/10/2014 15:35 HB V Lead <0.00500 mg/L 0.0050 1 04/10/2014 08:18 JRM 4/10/2014 15:35 HB V Zinc 0.0323 mg/L 0.0100 1 04/10/2014 08:18 JRM 4/1012014 15:35 HB V r Reportla -1020439-20140496091616 .CERTIFICATE OF ANALYSIS This report shall not be reproduced, except In full, without the written consent of Analytics Corporation Page 7 of 8 AANALYTICS ANALYTICAL RESULTS Workorder. 1020439 STORMWATER 477-2014 • Quallflers. Certification Index: V = Virginla (NELAC) -'1 VAC 3046 H 1, Laboratory ID: 460160, Certificate M 2770 r Report ID: 1020439-20140416091616 s CERTIFICATE OF ANALYSIS This report shall not be reproduced, except in full, without the written consent of Analytics Corporation IE Analytics Corporation 10329 Stony Run Lane Ashland, VA 23005 Phone: (804) 365-3000 Fax: (908) 365-3002 1. m Page 8 of 8 r ENVIRONMENTAE_ CHAIN OF CUSTODY ACCOUNT NAME AND ADDRESS J©HN DEERE TURF CARE, INC E501 NC HIGHWAY 55 EAST F'UQUAY—VARINA, NC 27526 Phone: 919-567-64413 1-919-5E•7—EE48 RROJ# : 32401015 DATE SHIPPED T g ZOIy �.dFSAMPLEs PROJECT NAME OR NUMBER - - - - r � L4-7_2dI q rA-I I A!�� T �� Ca , � �.•.,�•, 10329 Stony Run Lane Ashland, VA 23005 (804) 365-3000 Toll Free (800) 888-8061 Fax (804) 365-3002 PURCHASE ORDER NO. , �lS4130 27oN CONTACT - TELEPHONE r iUMBER �� K � �i�•�zss o�8- RUSH ANALYSIS Same DayPhone ❑ One Day ❑ Two Day. El Three Day Extra Charge E'n�AIL'aDDRESS: � � � n , = &��P � �; K inn .CpYb� F r-Fasc: SPECIAL_ INSTRUCTIONS: " MATRIX CODES - - - - - = ANALYSIS REQUESTED (Place an "X" in the box below to indicate request) x < m ° c° y 4 C1� Preservative Tempe turf Arrival Received on Ice: ❑Yes ❑ No A = AQUEOUS O ? _ z o S - SOLfD ~X =OTHER DW = DRINKING WATER W = WIPES COMMENTS Lab ID Sample Identification Date & Time VriS 01 4h! Iq Z n -2 G X W e) i �5S IN 2 m A W a AgAIJ QL 0;1 f G I q i' % A Z Cs X X TES dZ114 i:z P A i t t INpri+�.�;✓e L iMcW<. rsap A( X X X —41-7liq T7- SAMPLED BY'{PRINT NAME): _ •SAMPLED f1 BY (SiGNATU TO;INITIATE COC):. F DATfE 1q' TIME 1 r 9.30Q j I _ SAMPLES RECEIVED BY: {SIGNATU ) DATE TIME :- CON ITION -'SAMPLES,RELINQUISHED 8Y f (SIGNA-TURE) _ ` ¢ - , DATE '1IME` i CONDITION ENVCOC-01 (REV.412012 { : ,&ANALYTICS MOMMONAM Work Order: _ '1020439 Customer Name: JOHN DEERE TURF CARE, INC 32401015 STAND Sample Container Receipt Form Version 6-24-2011 CLIENT SAMPLE ID LAB CONTAINER -ID' - ,TYPE OF --j'QTY-' CONTAINER J.Temop- _ ';p --•-- I Chlorine on `Arrival (ppm)) Condition Code ;Preservative f WB OIL &GREASE 1020439001-B I° 1000G 1. 1 - _4_ _ I; _ - -!OK'-- WB OIL & GREASE 1020439001 f1: - - ,1000G - 1 -- i, -- -. Y�� -. - . -- _ (OK". . T .. - ! HCL ~9 WB TSS 1020439002-A 1.1000P - 1 .II4 ;JI�BT- WOK _. -- ITCOOL=_ WB METALS 1020439003-=A - �' ' 500P - _ _ _ , i � E� !, 4 2 - ,f„OK I HNO3 PL OIL & GREASE 1020439004=A 1000G 1 _ [ 4 ..- -,;�` _ I,-_ _ _ .*OK PL OIL & GREASE 11020439004-8 1000G F, 4 �; ,_ PL TSS 1020439005-A jJ000P 1;1- t �: ;b - _ - ;' .8- _-_- 1 - _ ':OiC i -COOL PL METALS 102043900 500P_ 1 _ _ 4 1 ;21 Notes i t Y Custodian Signature Date:, Version-11-13-2011 CML Page 1 of 1 r 4t v