Loading...
HomeMy WebLinkAbout19991011 Ver 1_COMPLETE FILE_19990922A _' State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director Xffl'?_?VA D E N R September 30, 1999 DWQ# 99-1011 Buncombe County Mountain. Area Child and Family Center 106 Ramsey S. Nelson Road Marshall, NC, 28753 Attn: Neil Leach APPROVAL of 401 Water Quality Certification Dear Mr. Leach: You have our approval, in accordance with the attached conditions, to construct a ductile iron force main along an unnamed tributary to the Swannanoa River, as you described in your application received by the Division of Water Quality on September 22, 1999. After reviewing your application, we have decided that this fill is covered by General Water Quality Certification Number 3101. This Certification allows to use Nationwide Permit Number 12 when the Corps of Engineers issues it. In addition, you should get any other federal, state or local permits before you go ahead with your project including (but not limited to) Sediment and Erosion Control, Coastal Stormwater, Non-Discharge and Water Supply Watershed regulations. Also this approval will expire when the accompanying 404 permit expires unless otherwise specified in the General Certification. This approval is only valid for the purpose and design that you described in your application. If you change your project, you must notify us and you may be required to send us a new application for a new certification. If the property is sold, the new owner must be given a copy of the Certification and approval letter and is thereby responsible for complying with all conditions. If total wetland fills for this project (now or in the future) exceed one acre, compensatory mitigation may be required as described in 15A NCAC 2H .0506 (h). For this approval to be valid, you must follow the conditions listed in the attached certification. If you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition which conforms to Chapter 150B of the North Carolina General Statutes to the Office of Administrative Hearings, P.O. Box 27447, Raleigh, N.C. 27611-7447. This certification and its conditions are final and binding unless you ask for a hearing. Environmental Sciences Branch 4401 Reedy Creek Road Raleigh, North Carolina 27607 Telephone 919-733-1786 FAX # 733-9959 An Equal opportunity Affirmative Action Employer 50% recycled/10% post consumer paper This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone John Dorney at 919-733-9646. Sincerely, Al? Kerr T. Stevens Attachment cc: Corps of Engineers Asheville Field Office Asheville DWQ Regional Office Mr. John Dorney Central Files 991011 1, . t ?1_ALfL?LFZT& BRIGH7- July y 27, 1999 Mr. David Baker, PE U.S. Army Corps of Engineers Rebnulatory Field Office 151 Patton Avenue, Room 143 Asheville, NC 28801-5006 RE: Pre-Construction Notification Application Submittal Mountain Area Child and Family Center Pump Station and Force Main Buncombe County, NC TBI No. 5903-9901 Dear Mr. Baker : .?f?srn£,rrr-;.? Enclosed is the original and one copy of the completed permit application form, two copies of the 't'echnical Specifications, two 8.5" by 1 I" plan views of the proposed stream crossing for the above project. The single stream crossing will be made below grade. The repair of the disturbed stream banks will be accomplished with placement of sod rather than stone rip rap. To de-water the stream bed and prevent sedimentation of the downstream channel, the contractor will be required to place a washed stone check dam and bypass pipe upstream of the proposed stream crosslm:. The actual trench excavation should only take about one hour. Therefore the dam and bypass pipe N?ili only be needed for a short period of the day. ]here has not been a determination of wet lands made at this crossing. The scope of the force main installation in the low land area adjacent to the siltall steam «ill disturbed at most an area of only 10' by 150' , less than 0.01 acres. The remainder of the project area is either previously disturbed agricultural pasture or forested high lands. The proposed pump station and tbrce main will be privately owned and maintained by tile %'fountain lrea Child and Family Center (\IACFC). The pump station is to be located on the \I.ACFC' site leased from Warren Wilson Colle>ie. If you should have any questions concerning the project or this application. please contact me at 010) 763-5350 ?m??ercl?, ?/ William L. \lorris, Jr., P.F. WIAlibutt ?,•? t'hrr !;??cer; 1, a A a NAT I ONW I N-: III-J?M I 'I' It l?(?)I11;?;'I'IEI) (PP(W I II NATIONWIDE PERMIT II ) PRE-CONSTRUCTION NOTIFICATION APPLICATION FOR NATIONWIDE PERMITS THAT REQUIRE: 1) NOTIFICATION TO THE CORPS OF ENGINEERS 2) APPLICATION FOR SECTION 401 CERTIFICATION 3) COORDINATION WITH THE NC DIVISION OF COASTAL MANAGEMENT SEND THE ORIGINAL AND (1) COPY OF THIS COMPLETED FORM TO THE APPROPRIATE FIELD OFFICE OF THE CORPS OF ENGINEERS (SEE AGENCY ADDRESSES SHEET). PLEASE PRINT. 1. OWNERS NAME: r ` j?0 f? 2. MAILING ADDRESS:_ & de, f`eC- 3. TELEPHONE NUMBER (HOME) (WORK) _. IF APPLICABLE: AGENT'S NAME OR RESPONSIBLE CORPORATE OFFICIAL, ADDRESS, PHONE NUMBER : , ( LL ex c e 61?1 6 - ( - d_ Q . -------- SUBDIVISION -- 5. LOCATION OF WORD: (PROVIDE A MAP, PREFERABLY A COPY OF USGS TOPOGRAPHIC MAP OR AERIAL PHOTOGRAPHY WITH SCALE): ;'OUNT'i_1?_??._???? -------- --- NEA: Ems"- TOWN OR CITY: d__y- -ow-a' Pi:CI ROAD NTJT,1BEFS, :S, ETC.1 r ` I r y,-1 r - - u . IMPACTED OR NEAREST STREAM/RIVER : LA-)- 6L.?N }: I VEf? D ,S1N l -' C!` b --4,?-. _ Gl NAME: CITY: ",? STATE: IVC- ZIP CODE: pL U ??j 3 PROJECT LOCATION ADDRESS, INCLUDING SUBDIVISION NAME (IF DIFFERENT FROM MATT.TMr r I:; PP04ECT LOCATEI) N1-:AP WA• I-'P CLASSIFIED A; '11"011 , l 11)A1, SALTWATER I:;AI 111(;11 QtJAI,1TY H1A'I'I:I :I 1110W) , 0U•17;TANDIN(; PI•::;,d)PCE WATER:; ((ww) 0.41:; I ?iP WS I11? Yli.`; I I LJc) I'?(I fP YI:.';, I:7.II,r,III: !I 11" THE PROJECT IS LOCATE[) WITHIN A NORTH CAROLINA Il 1 V I S ION OF COASTAL, h1AIJnCKf 1Rh1'1' ARE OF ENVIRONMENTAL CONCERN (AEC) ? YES I I NO (xj •7C IF THE PROJECT IS LOCATED WITHIN A COASTAL COUNTY (SEE PAGE 7 FOR LIST OF COASTAL COUNTIES), WHAT IS THE LAND USE PLAN (LUP) DESIGNATION: --? EIa. 1IAVE ANY SECTION 404 PERMITS BEEN PREVIOUSLY REQUESTED FOR USE ON THIS PROPERTY.' YES ( I NO KI IF YES, PROVIDE ACTION I.D. NUMBER, OF PREVIOUS PERMIT AND ANY ADDITIONAL INFORMATION (INCLUDE PHOTOCOPY OF 401 CERTIFICATION): 8b. ARE ADDITIONAL PERMIT REQUESTS EXPECTED FOR THIS PROPERTY IN THE FUTURE? YES ( I NO `!I] IF YES, DESCRIBE ANTICIPATED WORK: 9A. ESTIMATED TOTAL NUMBER OF ACRES IN TRACT OF LAND: 9B. ESTIMATED TOTAL NUMBER OF ACRES OF WETLANDS LOCATED ON PROJECT SITE: OP 10A. NUMBER. OF ACRES OF WETLANDS IMPACTED BY THE PROPOSED PROJECT BY: FILLING: EXCAVATION: _0. V g" FLOODING: OTHER: DRAINAGE: TOTAL ACRES TO BE IMPACTED: O 10B. (1) STREAM CHANNEL TO BE IMPACTED BY THE PROPOSED PROJECT (IF RELOCATED, PROVIDE DISTANCE BOTH BEFORE AND AFTER RELOCATION): CULVERT LENGTH: FT LENGTH OF BANK STABILIZATION: Q F-I, LENGTF BEFORE: ?- FT AFTER: FT WIDTH BEFORE (based on normal high water contours): - ? 0 FT WIDTH AFTER: FT AVERAGE DEPTH BEFORE: FT AFTER: D. S FT (2) STREAM CHANNEL IMPACTS WILL RESULT FROM: (CHECK ALL THAT APPLY) OPEN CHANNEL RELOCATION: PLACEMENT OF PIPE IN CHANNEL: CH:?IJiI :, ELEVATION: CONSTPUCTION OF .a DAX'FL0ODIN,-, :'r.?iCTIOPI OF A POND IS PROPU?; WHA- IS F SIZE OF THE WATERSHED DPAIN-'N TO THE POND? WHAT IS THE EXPECTED POND SURFACE; APEA? I f I7 I)(;1;r(11P'IION OF PROPOSED WOPF INCf,UDIN(; I)ISCII.`;SiON OI I'YI'I; OF MI:'IIANI('AL f:Qtlll'MI{t!'I 'I')) HE U SE.1) (ATTACH PLAN:; 11 X ) 1 " DRAW 1 NQI; O)t1I.Y ) 14 Q Z J Le c, 4e-ro l R,t lil CC? GL C) C/b55 , ,f 4T-ea S-A - Md 4-e 6 13. PURPOSE OF PROPOSED WORK: 14. STATE REASONS WHY IT IS BELIEVED THAT THIS ACTIVITY MUST BE CARRIED OUT IN WETLANDS. (INCLUDE ANY MEASURES TAKEN TO MINIMIZE WETLAND IMPACTS , , , 15. DOES THE PROJECT INVOLVE AN EXPENDITURE OF PUBLIC FUNDS OR THE USE OF PUBLIC (STATE) LAND? YES [ J NO [><j (IF NO, GO TO 16) a. IF YES, DOES THE PROJECT REQUIRE PREPARATION OF AN ENVIRONMENTAL DOCUMENT PURSUANT TO THE REQUIREMENTS OF THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT? YES [ ] NO [ ] b. IF YES, HAS THE DOCUMENT BEEN REVIEWED THROUGH THE NORTH CAROLINA DEPARTMENT OF ADMINISTRATION STATE CLEARINGHOUSE? YES ( ) NO [ ) IF ANSWER TO 15b IS YES, THEN SUBMIT APPROPRIATE DOCUMENTATION FRCS, THE STATE CLEARINGHOUSE TO DIVISION OF ENVIRONMENTAL MANAGEMENIT REGARDING COMPLIANCE WITH THE NORTH CAROLINA ENVIRONMENTAL POLICY ACT. QUESTIONS REGARDING THE STATE CLEAPINGHOUSE REVIEW PROCESS SHOULD BE DIRECTED TO MS. CHRYS BAGGETT, DIRECTOR STATE CLEARINGHOUSE, NORTH CAROLINA DEPARTMENT OF ADMINISTRATION, 116 WEST JONES STREET, RALEIGH, NORTH CAROLINA 27603-8003, TELEPHONE (919) 733-6369. 16. THE FOLLOWING ITEMS SHOULD BE INCLUDED WITH THIS APPLICATION IF PROPOSED ACTIVITY INVOLVES THE DISCHARGE OF EXCAVATED OR FILL MATERIAL INTO WETLANDS: a. WETLAND DELINEATION MAP SHOWING ALL WETLANDS, STREAMS, LAKES AND PONDS ON THE PROPERTY (FOP, NATIONWIDE PERMIT NUMBERS 14, 15, 21, 26, 29, AN'D 38). ALL STREAMS (INTERMITTEt1T AND PERMANENT) ON ':..E PROPERTY MUS,. °= SHOWN Ott THE tf •.' E4'TAL.: r _ ?- t,_'... r21J :._ _.. FEET OP THE: h. IF ;,`!A.ILAALE, RF,PRESENTATIVF. PHOTOGRAPH OF WETLANDS TO 13E i'MPACTED BY PROJEC'T' IF DELINEATION WAS PERFORMED BY A CONSULTANT, INCLUDE ALL D=.TA SHEETS RELEVAt1'?' TO THE; PI,ACI MI?N'I' OF THE DEI,I:NEATION LINE I 1 d. ATTACH A COPY OF THE STORMWATER MANAGEMENT PLAN IF REQUIRED. P/ e. WHAT I', I,AND USF OF SURROUNDING hR(:)1)IiR'I'Y? ?. _ t.. C (J 4u re ..-G- s OY`j.res f. IF APPLICABLE, WIIAT IS PROPOSED METHOD OF SEWAGE DISPOSAL? IL.( n N r I(J ' f? Cd I ?2a `f- &-` cT SJ A- M g. SIGNED AND DATED BY AGENT AUTHORIZATION LETTER, IF APPLICABLE. NOTE: WETLANDS OR WATERS OF THE U.S. MAY NOT BE IMPACTED PRIOR TO: 1) ISSUANCE OF A SECTION 404 CORPS OF ENGINEERS PERMIT, AND 2) EITHER THE ISSUANCE OR WAIVER OF A 401 DIVISION OF ENVIRONMENTAL MANAGEMENT (WATER QUALITY) CERTIFICATION'. OWNER'S/AGENT'S SIGNATURE D E (AGENT'S SIGNATURE VALID ONLY IF AUTHORIZATION LETTER FROM THE OWNER IS PROVIDED (16G.)) ?-••- (? G /?'`? c o ? M o4-C? ---------------------• ------ w ------------------- ED ? D 1 ? r ' I •z ? U .w ? Iv IG IN ? v ? r •?I y I ? \ I I - ? I i ? z m to Z T- jw r '1s S 3 Oh Job " G r G -f 3 s. N N K ? N o ? ?? ,? Ogg \?\\ ell J. Z v N OL CL r Q W U 0 U- 2 0 W N O n ?g d ^o i I i Q? c N? c ?r c az 0 za +c c `zr ?(Y) cA O L c. IUW' ?O N ;W? C ? W 2 J L? J U a N .- 0 0 N 0 0 0 N O O + rn ww 2 dr- CL D U i TECHNICAL SPECIFICATIONS MOUNTAIN AREA CHILD AND FAMILY CENTER PUMP STATION AND FORCE MAIN PROJECT BUNCOMBE COUNTY, NC TBI No. 5903-9901 JULY 27,1999 PREPARED BY TAL,BERT & BRIGHT, INC. COTTON EXCHANGE 321 NORTH FRONT STREET WILMINGTON, NC 28401 910-763-5350 . I , . , SECTION IV SPFiCIAL CONDITIONS 1. PROJECT DESCRIPTION (a) The work to be performed shall consist of the construction of the Mountain Area Child and Family Center Sanitary Sewer System Improvements, Swannanoa, North Carolina. (b) The work shall be performed under one unit price contract, No. 99-20, and shall consist of furnishing all materials, supplies, and equipment; perform- ing all labor and services incidental to or necessary for the complete construc- tion of the project in accordance with the plans and specifications; and mainte- nance of each completed portion of the work until final acceptance of the entire project by the owner. 2. CONTRACT PLANS (a) The work shall be performed in contract plans, which are incorporated are identified by the following numbers accordance with these specifications and herein as part of the contract and which and titles: Drawina Number Title SS-101 PUMP STATION AND FORCE MAIN PLAN AND PROFILE Sta. 10+50 - 25+50 SS-102 PUMP STATION AND FORCE MAIN PLAN AND PROFILE Sta. 25+50 - 35+49.89 (END) SS-103 SS-104 PUMP STATION DETAILS FORCE MAIN DETAILS 3. TIrJE QF COMPLETION AND LIQUIDATED DAMAGES (a) The time allowed for completion of all work shall be 90 calendar days, subject to allowable delays as stated in Paragraph 7.2 (d) of the General Condi- tions. (b) Liquidated damages for failure to complete the work within the speci- fied time, as provided in Item 7.2 of the General Conditions, are hereby mutually fixed and agreed upon at the rate of three hundred dollars ($300.00) per day. EK: VP.TI:)N and classes excavatlo:: shall oe class._`le14 1s common .3! '{'•.1`?a'__... _.'?a_atET D3`! ?P hili be ma-..e f-,r any .'_.'c{ exzava--ion encouP.- `'rC PX^.:?'Ja Ced mdt'r iai I10t Inee% the rey'li semen. S of paragraph ;._•i of tn? Techn_cal pecificati;ns fr... "ba^kfill material," it shall be removed from the site a::: replaced with suitabie n,]aterials. No separate payment shall be made for this work. 5. -PrVEMEN'T REM(D/AL AMD RFPLFCEMFNT (PRIVATE DRIVES AND PARKING LOTS) ia) Prior to excavating, pavement to be removed shall be marked with chalk line_ cut as described for :.(COT pavement cuts. b; The tren;.:h in open-cut private drives and parking lots shall be backfi- .lle:: in acc)rda:,.ce '.rith paragraph 1.14 of the Technical Specifications. ::) =avt=m?::t removal anci replacement for private drives and parking lots and is?c7, a x; -:;n- pa emen' n , Ta` base '_.r se e t ?L2S11A. % 1. 7. ;. `. c`'.+ t znct:, ;;ompacte,z CO 00 stan,.ard proc,"C': dens: ty. .; borough application; of tack coat applied to the edges of the existing pavemen`. cDurse, NCDOT speciiicat_.... Hype HDS. [i].tilminOllS ., dCe rdCrOr ...9' nla..' she st )n.P Vase _l'!sh '•i_._.. the exls inc, place the finished bituminous surface course within 7 days of completing the trench backfill. (d) Payment for pavement removal and replacement for private drives and parking lots shall be made at the contract price 'square yard", to the nearest 1/10 square yard. 6. REPLACEMENT OF CRUSHED STOKE SURFACES (a) Replacement of crushed stone surfaces shall consist of an eight (8) inch crushed aggregate base course of Type I crushed stone, compacted to 100 standard proctor density. (b) Payment for replacement of crushed stone surfaces shall be made at the unit Price Per Square Yard quoted in the bid documents. Measurements will be made to the nearest 1/10 square yard. 7. FENCE REPLACEMENT (a) All fences crossed by the sewer line shall be replaced promptly after backfilling the trench. Fences shall be replaced with the same type of construc- tion. All materials shall be new and of good quality. No separate payment will be made for fence replacement. 8. STANDARD MANHOLES (a) Standard manholes shall be precast concrete structures and meet the requirements of Item III, Paragraph 3.16 Manholes, of the Technical Specifica- tions except as revised herein. (b) Paragraph 3.16 (c), of the Technical Specifications is revised to include that the required 28 day compressive strength of concrete used in the manufacture of manholes shall not be less than 4,000 pounds per square inch. The minimum wall thickness of manhole base and riser sections shall be seven (7) inches for seven (7) foot diameter manholes, eight (6) inches for eight (8) foot diameter manholes, and ten (10) inches for ten (10) foot diameter manholes, The minimum thickness of the bottom shall be eight (8) inches for seven (7) foot diameter manholes, ten (10) inches for eight (8) foot diameter manholes, and twelve (12) inches for ten (10) foot diameter manholes. (c) Paragraph 3.16 (d) of the Technical Specifications is hereby revised to trnclude that i-: addition to the rubber gasket_ and flexible sealant to be in- -a...?? `hc manhole sects ,?.s, .._..-nk gr ;u`_ s ._., be applied. :h s.. _ _. ar _ .,ar....,_e s _ _r,ts an;' __". holes both 1..^. _'1 Sld^ he Tant:', E, i^ _._._._raa-:_ Jwithe manufacturer's sealant extrr.e-1 oljt of the .,:anhole joints sna,.: z;e c .._ ba;! _,) a. _"w 1/ 14 inch, Ali n_mum of the joints. Ma:: er by Masher or approve` _q- al, shall be use_:. (d1 raragr-Iph 3.16 (q) of the Technical Specifications is hereby revised to include, the frame shall be anchored to the concrete cone section with expansion anchors as specified in Section 16 of these Special Conditions and detailed on the Miscellane?,us Detail Drawings in the plans. (e' Mlanh^le Frames and Covers shall be watertight as specified in Section c` th?se SPec_a1 Conditions and detailed or, - ail Drawings the Miscellaneous et i'? the [ - (fi 're-cast Concrete Manholes shall not be shipped to the ;ob site prior `neir date of manufact1.1re. ''Ia:.... manhole tees shall br. vacua::, tested after. completing pipe ser?__. bu' efora tac:f____. _ r:) 1 ra^.t and cover as estor head . assem-•• against iiltcri0- serfacr, ;:>? th ton of the cone section. and in ate a_-co :-ding to the manuPaer': reco?2?;endati0n3 _rav i vacuur.,,. ,i' 10" of mercury, close the valve o" the vacuum It (4) Measure the time for the vacuum to drop to 9" of mercury. The manhole shall pass when the time to drop to 9" of mercury meets or exceeds the following: Manhole I.D. (inches) 48 60 72 84 96 120 Seconds 60 75 90 105 120 150 (5) If the manhole fails the test, remove the head assembly and coat the manhole interior with a soap and water solution and repeat the vacuum test for approximately 30 seconds. Leaking areas will have soapy bubbles. Make the necessary repairs and repeat the test until the manhole passes. (h) Manholes shall meet all other requirements of Paragraph 3.16 of the Technical Specifications. (i) Payment for manholes will be made at the unit bid prices in the bid documents for each manhole installed and accepted, at the standard depths listed in the bid documents. Extra depth of manholes will be paid for at the unit bid prices, per vertical foot, in the bid documents. Measurements for extra depth of manhole, for the various sizes, will be made to the nearest 1/10 foot. Measurements will be from the top of frame to finished invert, less the standard depth. Payment for manholes shall include all labor, equipment and materials, as specified herein, and in the Technical Specifications, and as detailed on the Miscellaneous Detail Drawings in the plans, for a complete and accepted manhole ready for service. 9. (a) Force main manholes shall be precast concrete structures and shall meet the requirements of Item III, Paragraph 3.16, wholes of the Technical Specifi- cations, and Section 8, Standard Manholes, of the Special Conditions, except as modified or specified otherwise herein. (b) The proposed force main manholes are designed and shall be constructed for future conversion to a gravity sewer with minimal modifications. (c) The force main fittings shall be constructed inside the force main manhole as follows: (1) The force main pipe shall extend 2.5-3.5 inches beyond the inside wall of the manhole and shall have a grooved end for attachment of the pipe cou- pling. (2) Mechanical joint pipe beads shall to centered in the force main man- hole. 31 betwee;, c•.i, __: ;s an mechanical -in': bends shall _.. s 3.: file iron a-.; a p»_n end and shall be requi _.-. length to pro.>?riy .`': o-.-. 4 ) inor 13. in _h?- .,u...._fa::_urer s spec: tolerances, stall b- made at "file: mechanl,. l achievF- the deflection ang'es 3'` `-ie orce main ma-1nc)Les as s_^.?_ifie,-i on the dra',4_ngs. (5) Manhole entrance joints shall be as specifies,' in Ite: .II, Paragrap'i 3.16, Manholes, of the Technical. Specifications. (6) The floor of the force main manholes shall be built uz underneath the mechanical jr)int bends with non-shrine: grout. The mechanical joint bends shall be secure.: with galvanized bands wide x 1/4-inch thick, as shown on the drawings. (d Paymer:t for force main manholes will be made at the uni_ bid prices i- t e bid documer.'_s for each manhole installed .nd accepted, at _ne standard depth listed in 'he bid documents. Extra dept of manholes wili be pa;d for at the a.1 l.- ' foot _ i -.- bid ,.., ,iments. ? _ SUr2mer.t5 for . It bi'' prices, "%-c r t depth, f.'D ea .`. .i ['.e air. iaan<< wl i e -:a de tC nearest 1/1r ^.12a:'a dulE:ifs l;3Cc i'. %%- _..Jeri: 7?f ?..- an'?, i_._..ingS iv':l_ 2 Cal.. io Separa_e r :cs _ De 1: ___C-. L6 of _.i.. r ecla.I C,,.ndit1Dns, :.. SE;WZR FORCE '*VVUN he -. _ Specified or r I (b) Fittings shall be as specified in Item III of the Technical Specifica- tions. . (c) The proposed sewer force main shall be installed true to lines and grades as shown on the drawings and as specified in Item III, Paragraph 3.04, pipe Laving, of the Technical Specifications. Pipe (d) Pipe couplings shall be Victalic ductile iron couplings, Style 31, or approved equal. (e) The sewer force main shall be hydrostatically tested from the submers- ible sewage pumping station to the point of discharge in accordance with Item III, Paragraph 3.09, Hydrostatic Testing of Pressure Sewer Pipe, of the Technical Specifications (f) Payment for the sewer force main will be made at the unit bid price, "linear Foot", (L.F.), in the bid documents. (g) Measurement of the sewer force main shall be the horizontal length in place measured along the center line with no deduction for fittings. (h) Payment for fittings shall be made at the unit bid price "pound", (LB), in the bid documents. (i) Payment for the sewer force main and fittings shall include all labor, equipment, materials and testing, as specified in the Technical Specifications and detailed on the drawings for a complete and accepted sewer force main. 11. MANHOLE FRAMES AND OVER (a) All manholes frames and covers shall be watertight as specified herein and as detailed on the Miscellaneous Detail Drawings in the plans. (b) The frame shall be fastened to the top of the pre-cast concrete manhole with four (4) 5/8 inch diameter galvanized steel wedge anchors. The anchors shall have a minimum of 1-1/2 inches of threads exposed above the top of the frame flange and shall extend a minimum of 3 inches into the top of the concrete cone section. A bituminous flexible sealant shall be installed between the frame and the top of the concrete cone section to ensure a watertight joint. Where the manhole frame requires elevation adjustment, the contractor may use 5000 psi grout to completely fill the space between the precast concrete cone and the bottom of the frame, per the detail shown in the place. (c) The manhole cover shall have a rubber gasket which will seat against the inside edge of the frame to form a watertight seal. (d rames a::d covers shall be equipped a one clece pentaa:Dn headed cam type _....n, devices constructed entirely cf stainless s-eel __mens-ions of s':-,_i_ be 3/4 inch frorn. flat e .._ opp, s `e .???.,...?.-_ _a m- and c::)vars shall be ie•h-?y W r ,.. .?_... _._, _ a c _.-_^? "Va t.a_rt ? r? 1qh: _, or approved QG . _ cares a, cov .. er shad _.. _ :e : _ or isa ?.' ma _ N,': separata payment will be n'.aCle frames an.'" (aJ 7roperty corner markers shall be protected from the cons_ruction by the Contract:r. Where property corner markers are disturbed by to Contractor's opera ti3::s, they shall be replaced at the Contractor's expense by a Land Surveyor c:=en'1-_: licensed to practice in North Carols -. ,. 4i=`;:'•' DEPT- 07 COVER (a' 3.1` (a) shall be modified provide at leas- ?.0 feet of _ oncr°*e pipe nr prn;, r.'li._ t' ?or.crete ' -. _ ..-..? . _. _. ... _.. .. --.' vii. -?.. '_tL_ JOE ?. Di:3 LAW ( 19. _ N,)rth Carolina Legislature e::acted the "U; .de- round Damage ". ..._s _iw applies to any excavai_-:, perform._.., b- -_. .. ractor in 4 , spells out responsibilities for the owner, the contractor, and the underground utility during the construction phase. (b) The Owner or the Engineer will provide the Contractor with the names of all underground utility owners in the area of the project during the Pre-Con- struction Conference. (c) In North Carolina the "One Call System", called "ULOCO", can be uti- lized by calling 1-800-632-4949 (919-855-5760 for calls originating outside of North Carolina). ULOCO will notify each individual member utility owner which has underground utilities in the area of the proposed excavation. (d) The Contractor shall be responsible for meeting the requirements of the Contractor under the law. 15. EROSION CONTROL AND SEEDING (a) During the construction of the project, the Contractor shall be re- quired to take the necessary steps to minimize soil erosion and siltation of rivers, streams, lakes, and property. The Contractor shall comply with the applicable regulations of the appropriate governmental agencies in regard to soil erosion control and sedimentation prevention. (b) The Engineer will limit the area over which clearing and grubbing and excavation operations are performed whenever the Contractor's operations do not make effective use of proper erosion control measures. (c) Prior to the end of each work day on the project, the Contractor shall take the necessary measures to protect the construction area from erosion. (d) Temporary and permanent erosion control measures shall be accomplished at the earliest practicable time. Temporary erosion control measures shall be coordinated with permanent measures to insure economical effective and continuous erosion control during the life of the project. (e) Temporary erosion control measures shall include but not be limited to the use of temporary berms, dams, dikes, drainage ditches, silt ditches, silt fences, vegetation, mulches, mats, netting or any other methods or devices that are necessary. (f) Erosion control measures installed by the Contractor shall be suitably maintained by the Contractor. (g) Where excavation is adjacent to streams, lakes or other surface waters, the Contractor shall not place excavated materials between the excavation and the surface waters. Where this practice is impractical, the Contractor shall provide erosion control measures as authorized by the Engineer. `. ere 11ve .3 ream_ are .,3ssed b, rtract^r shah. r`icu_Gr care to s_itat__:. _Z: strea: Te-,p far erosio. _.-.,_ '..9asure3 snail be aS C,'. 7,=ee... hese may _ :)t e _iml P-1 tc -I-; Ke_ -- _ divers _ n _ _ ,ne s a` `n,, tom, the banks te;:r:rar, erc'sic:. _:on: _ measures shall 3:.. .._i'. ..ces on the K ban '-"S. C _ d.:CeC =: Ley mainta ned u'!til permanent eroS icn measur,._? are implement- e:.. Permanent eresion control measures at stream crossings shca' _ i-. elude but not b iir:i'e1 to d jimped rip-rap on the cree}; banks and the establishment of permanent grass cover on all disturbed and exposed soil. where runoff on natural ground may cause erosion cf the trench or erosion J` the backfill in the trench, the Contractor shall construct temporary erosion -c ntrol measures. These may include but riot be lim.ite_, to diversion '_ an-1 Silt basi ns or owner suitable e_resion control measL;-.:-2s as authorized L)% ^:e -. _neer. :.Iearin:; and grubbing :operations shah be 1-4,mited to a maximun, of three -.cl,asar:.: .-,000) feet ahead of uio2 crews. Temporary erosion con- _ :.? .. rPs shall be b;; t::e Contractor ..:eared areas cf the These limited tc ntract.: e":o_?- _ ?es_._. -i - - - aJ neer . _ oI 5. ai.;. :.; -,:ac ? c than 5l -=2` aaE'a;i of tempo- rary narmanent seeding of disturbed areas. Seeding shall meet the require- ments _ _tem III f the Technical Specificatic)ns. ?e-seeding f:`_ (?evelcpr?J i awns sha' ma-.:;n i. 1? exis'. i. grass type as ...em VI :` (m) No separate payment will be made for any temporary or permanent erosioft control measures including grassing and seeding unless specifically included in the proposed unit items. 16. SOD FOR STREAM BANK pgOTECTION (a) Solid strips of kentucky bluegrass/ tall fescue sod shall be placed where specified on the plans to protect stream banks that have been disturbed by the construction. The sod shall be placed perpendicular to the stream flow to form strips from the stream bottom to the top of the bank. The sod shall be placed conforming to the existing stream bank slope and alignment leaving the sod surface flush with the adjoining existing surfaces. (b) The edges and center of the sod strips shall be securely fastened down with 12 inch long metal staples wooden pegs to prevent lifting by the stream current. (c) The installation and maintenance of the sod shall be performed in accordance with Section 6.12 SODDING of the North Carolina Erosion And Sediment Control Planning and Design Manual. (d) In accordance with the provision of Item I, Paragraphs 1.23 and 1.24, payment for Sod For Stream Bank Stabilization shall be made at the contract unit price in the proposal. 17. DISPOSAL OF UNUSABLE MATERIALS (a) All trees, limbs, brush, stumps, large roots, and rubbish shall be removed from the construction site. Neither the construction site nor the adja- cent property is available for disposal of unusable, demolished, or excavated materials. As indicated in Item I, Paragraph 1.19 of the Technical Specifica- tions, the Contractor shall dispose of these materials off the site at a location chosen and obtained by the Contractor. (b) The Contractor shall have the off-site disposal location approved by the Land Quality Section, North Carolina Department of Environmental Health and Natural Resources. (c) Provisions for erosion control and seeding shall apply for off-site and on-site disposal. (d) No separate payment will be made for the disposal of unusable, demol- ished, or excavated materials. 18. PAY`^7NT Fr)F ,4AT RIPLS ANn EQUIPMENT DELIVERED Tn TN- PR?? 7"?"" IT (a; When t;^:e Owner has paid the Contractor for rater a_s and equipment delivere_: tQ the project site with the monthly payment for w,3rG performed, the .'ontractcr shall make payment for these materials and equipment an., shall present inv71?e5 marked ??1d" to `he Owner as evidence of suc': payme:.'. :n the event -nat these invoices are not presented to the Owner with' sixty SC;, days after receipt. :;f s,;:h payment, the amount previously paid :-e Co::tractor for such ,:aterials and equipment will be deducted from the next payment tr• -he Contractor. 19. NON-SHRI.NK GROUT (a) Non-shrink grout shall be used where indicated, on the clans or in the specifications, shall be non-metallic cementitious type grout, and shall have a compressive strength equal to or greater than 5,000 PSI at 7 days curing time. (b) Prior t:) placing grout, all surfaces shall b-2 thorc,;c~ly cleaned to remove all dirt, oil, grease and all other bond-inhibiting materials. Concrete surfaces shall be brought to a saturated surface dry condition. ;rout shall be placed ..ithin 1 minutes of mixing. CjroLit shall be Sikagrout 212 grout as mane :..,. -rec. 3ika Corporationi M a5', eZ'flOw r 3 " ' _ non -3'..ink ce:'.=':ri01::5 yrOU? :-Ias`_eZ apprOVed ° `f l:._. w?. ; .v_.. C,e .; -s_derel a` i. Ln-* ,er-_1_ - - -ne w- 20: STREAM CROSSING EXCAVATION (a) The Contractor shall de-water the stream bed prior to initiating trench excavation across the stream. De-watering shall be accomplished by placement of a stone dam upstream of the pipe crossing and installing one or more( as neces- sary to prevent over-topping or washing around the edges of the dam) twenty (20) foot sections of 12" diameter CMP, PVC or corrugated HDPE bypass pipe to span the pipe trench. (b) The stone dam shall be constructed of hand placed washed rip rap( 3" to 12" size) to a height of no more than 1.5 feet. The upstream face of the rip rap dam shall be covered with a filter fabric and then an 8" thick mat of 3/4" washed stone. Care shall be taken to not disturb the natural steam bed under the dam during construction or removal of the dam. (c) The trench excavation shall be performed in a manner that will not create sedimentation of the downstream channel. The top layer of sand and natu- ral river rock shall be stock piled for later reuse in backfilling the trench. Any silty or clayey soils below this layer shall be excavated and removed, not to be reused as trench backfill. (d) The trench in the wetted stream area shall be backfilled to a depth of 6" below the natural stream bottom with washed 3/4" stone. The last 6" shall be backfilled with the natural stream bed sand and rock materials that had been removed and set aside for this purpose. (e) If solid rock is encountered before the three (3) foot depth is reached, the ductile iron pipe shall be encased in 2,000 psi concrete to a depth of 6" below the natural stream bottom to prevent floatation or movement of the pipe. If the rock depth is less than that required to fully encase the pipe with a 6" concrete cover and still be 6" below the natural stream bottom, then in lieu of the concrete encasement, the contractor shall anchor the ductile iron pipe with stainless steel bards with red head stainless steel anchor bolts set into the solid rock. (f) in all trench conditions, the Contractor shall layout the ductile iron pipe so that the rots are 10 feet either side of the stream centerline. SECTION VIII TECHNICAL SPECIFICATIONS ITEM I EXCAVATION 1.01 Scope (a) The work covered by this item shall consist of clearing and grubbing, loosening, loading, removing and disposing in the specified manner, all wet or dry materials of whatever character, including pavements and sidewalks, which are necessary to be removed for construction purposes; grading of the site and access roads, constructing rolled filled embankments; removing and replacing topsoil; furnishing, placing and maintaining all sheeting, shoring, bracing and timber necessary for the proper protection of the work and the safety of the workmen and the public; drilling and blasting; the backfilling and tamping of trenches and foundations; the removal of unsuitable materials from outside the normal limits of excavation and the replacement of same with suitable materials; and all other grading and excavation work incidental to or necessary for the construction of the work. This item shall also include all necessary dewatering of excavated trenches and areas. (b) On unit price contracts, common excavation and the backfilling of trenches for sewers or other pipelines and for manholes, valve boxes, and all other pipeline appurtenances shall be performed in accordance with the require- ments of this item (Item I), but shall be paid for as part of the work performed under Item III. (c) On unit price contracts, pipe embedment materials and their applica- tion shall be performed in accordance with the requirements of this item (Item I), but shall be paid for as a part of the work performed under Item III. (d) On lump sum contracts, no separate payment will be made for excavation of any kind nor crushed stone, pipe foundation material, pipe embedment materia- ls, and dumped rip-rap unless specific bid items and bid prices are, provided in the Proposal. 1.02 Preparation of Site (a) Prior to starting construction operations, the Contractor shall remov- all vegetable growth, debris and other objectionable matter sanding or lying o the surface within the limits of the areas to be excavated o,- " Lled; and shai'. demolish and remove therefrom such buildings and other structures as are specifi- cally designated on the plans for removal. Removal and disposal of such materi- als shall be done in a manner acceptable to the Engineer. (b) Areas occupied by trees, brush or other vegetable growth shall be cleared of such growth and suitably grubbed. All large roots or stumps shall be removed to a depth of at least two feet below original ground surface. Any pits or cavities thereby created which extend beyond the excavation limits shown or, the plans shall be filled with the materials and in the manner specified i:,. Paragraph 1.04 of these specifications. (c) Ornamental trees, cultivated shrubs, and similar growth which occup%. streets, alleys, or other public rights-of-way or easements, but which lie out- side ~e exact limits of excavation shall remain undisturbec anc! shall be car=- 7reser-led and -jrotected by the Contractor throughout all stages of t': -or.st° .C:: On wort:. «here appropriate, ornamental shrubb- ? ad _ree branch. shall be tied back to minimize damage. Trees which rece:.-f damage to branch, shall be trimmed of those branches to improve the appearance of the trees. Tre_ trunks receiving damage from equipment shall be treated with a tree dressing. (d) The Owner will secure rights-of-way or easements where require('. throur.'n private lands, but the Contractor shall give due notice to tenants there- in, a^.d shall be responsible for damage to property the e'_.. Each buildin;- wal'_ =ence bole, bridge, railroad. tree. lawn, or other - `: or improveme-- an','... --e-ed., whether aubl-c or or ace. yhai_ be c:ire_111. __--ected from a. injury, and, in case of damage or removal, shall be completely repaired or re- stored to its original or better condition. All damage to such improvements and all damage to property or persons resulting from damage to such improvements shall be borne by the Contractor. Special care shall be taken in trenching under or near buildings and railroads, to avoid or minimize all delays, damage, or injury thereto. (e) Exploratory excavation shall be made when necessary for locating underground utilities. Every pipe for water, gas, drainage, or other use, and every conduit, foundation or other "underground structure" encountered in trench- ing, shall be carefully protected from injury or displacement. All damage to such structures and pipelines and all damage to property or persons resulting from damage to such structures and pipelines shall be borne by the Contractor and shall be completely repaired within a reasonable time. No claim shall be made for damage or delay of the work on account of the proximity of, or the leakage from, such structures and pipelines. Where high pressure gas lines are to be crossed, they shall be uncovered by hand excavation methods before other excava- tion near them is started. (f) Preparation of the site as specified above will be considered as an integral part of the excavation, and no separate payment therefor will be al- lowed. 1.03 Site Grading or General Excavation (a) Sites for treatment plants, pumping stations, storage ponds, lagoons, reservoirs, and access roads shall be graded by mechanical equipment within the areas and to the elevations shown on the plans. Grading operations shall be conducted so that material shall not be removed or loosened beyond the required limits. The finished surfaces shall be left in reasonably smooth and uniform planes such as are normally obtainable from the use of hand tools; but if the Contractor is not able to obtain the required degree of evenness by means of mechanical equipment, he will be required to use hand labor methods. Slopes and ditches shall be neatly trimmed and finished to conform to the slope lines shown on the plans or as staked by the Engineer. (b) Topsoil from the surface of the ground to be excavated or occupied by fills, within the general area specified to be planted with grass, shall be "stripped" or removed before site grading or other excavation work is started. Topsoil so removed shall be stockpiled at a suitable location on the site of the work so that it can be reused later for planting grass as specified in Item VI of these specifications. This "stripping" operation shall remove all leaves, loam, and loose topsoil which are unsuitable for foundations. The depth to which top- soil is removed shall be determined by the Engineer, but will be generally be- tween the limits of two and six inches. (c) No separate payment will be made for the removal and stockpiling of topsoil; except that on unit price contracts, topsoil removed from areas which are to be excavated will be included in the pay quantities as common excavation. On unit price contracts, topsoil shall not be removed from areas to be excavated until the original ground surface has been cross-sectioned for the purpose of determining pay quantities. L.0 Structural Excavation a) Excavation for structures shall be sufficiently large for the proper placing of forms and concrete and for dewatering purposes, but shall not be excessively large in horizontal area. Banks may be sloped at a safe angle pro- vided that such excavation does not endanger or damage existing or proposed structures, pipelines, etc. The bottom of the excavation shall be true to the required shape and elevations shown on the plans. No earth backfilling will be permitted under structures unless specifically shown or. tht ans. Should the Contrac_or excavate below the elevations shown or specified, s:;all fill th,, R - 1 - I ' void thus made with Type I crushed stone (as specified in Paragraph 1.15 of these specifications) and thoroughly compacted or with Class B concrete at his own expense. (b) On unit price contracts the horizontal limits for structural excava- tion will be measured for payment between the vertical planes passing 12-inches beyond the outer vertical surface of the structure or beyond the outer edge of the structure footing, whichever is greater. (c) When muck, quicksand, soft clay, swampy or other material unsuitable for foundations are encountered which extend beyond the limits of the excavation, such materials shall be removed and replaced with crushed stone acceptable to the Engineer and thoroughly compacted, or with Class B concrete. (d) In all cases where materials are deposited along open excavation, they shall be placed so that in the event of rain, no damage will result to the work or adjacent property. 1.05 Trench Excavation (a) Trench excavation or excavation for pipelines shall consist of ex- cavation necessary for the construction of sewers, conduits, water lines, and other pipelines and all appurtenant facilities therefor, including manholes, inlets, outlets, concrete saddles, pipe embedment materials, and pipe protection as called for on the plans. It shall include site preparation, backfilling and tamping of pipe trenches and around structures and the disposal of waste mater- ials, all of which shall conform to the applicable provisions of these specifica- tions. (b) Trench excavation shall be made in open cut and true to the lines and grades shown on the plans or established by the Engineer, unless tunneling or boring is shown or specified. When practical the banks of the trenches shall be cut in vertical, parallel planes equidistant from the pipe center line. The horizontal distance between such planes, or the over-all width of trench, shall vary with the size of the pipe to be installed; The over-all width of trench shall be of the dimensions shown on the plans. When sheeting is used, the dis- tance between vertical planes shall be measured from the inside faces of the shee`_'nr. women vertical banks for trench excavation are not practical to con- struz:: or create dangerous conditions to workmen, the banks may be sloped pro- vide.: _'nat such excavation does not damage adjacent structures. When trench bank: are sloped, such banks shall be cut to vertical planes as specified above for that part of the ditch below the level of 12-inches above the top of the pipeline. On unit price contracts, the width of excavation, including rock excavation, to be used in the determination of pay quantities shall be as shown on the plans. The bottom of the trench shall be level in cross section and shall be cut true to the required grade of the pipe except where concrete cradles or pipe embedment materials are shown on the plans, specified or authorized by the Engineer, in which case the excavation shall extend to the bottom of the cradle or pipe embedment materials. (c) Bell holes for bell-and-spigot pipe shall be excavated at proper intervals so that the barrel of the pipe will rest for its entire length upon the bott--m of the trench. Bell holes shall be large enough to permit proper instal- lati :. -)f icints n the pipe. Bell holes shall not be excavated more than 1 aneac of _ca laNing. -::ca--a---on for manholes and o-her pipeline str•,:ctures shall be spe__" ed for structural excavation. (e) "hen muck, quicksand, soft clay, swampy or other material unsuitable for -foundations or subgrade are encountered which extend beyond the limits of the excavation, such material shall be removed and replaced with pipe foundation material as specified in Paragraph 1.16 of these specifications. ?ipe `renches shall not be excavated more than 300-feet in advance o. P,_ a•: i.cl:,; 1'_1 wor: shall be performed so as to cause th least possibl ir. -:ie public. Temporary bridges or ._rosswalks shall be constru<, - ted where necessary to maintain vehicular or pedestrian traffic. Crosswalks and bridges shall have handrails or other features necessary for safe use by the ublic P (g) In all cases where materials are deposited along open trenches, they shall be placed so that in the event of rain, no damage will result to the work or adjacent property. 1.06 Sheeting Shoring and Bracing (a) The sides of all excavations shall be sufficiently sheeted, shored and braced whenever necessary to prevent slides, cave-ins, settlements or movement of the banks and to maintain the excavation clear of obstructions that will, in any way hinder or delay the progress of the work or endanger workmen. Wood or steel sheet piling of ample design and type shall be used when necessary. All sheet- ing, shoring and bracing shall have sufficient strength and rigidity to withstand the pressures exerted and to maintain the walls of the excavation properly in place and protect all persons and property from injury or damage. (b) Where excavations are made adjacent to existing buildings or other structures or in paved streets or alleys, the Contractor shall take particular care to sheet, shore and brace the sides of the excavation adequately so as to prevent any undermining of or settlement beneath such structures or pavement. The Contractor will be liable for any damage to any structure or injury to any person that results from his operations. (c) Sheeting, shoring or bracing materials shall not be left in place unless as shown by the plans or permitted by the Engineer. Such materials shall be removed in such manner as will not endanger or damage the new structure or any existing structures or property, either public or private, in the vicinity, and so as to avoid cave-ins or slides. All trench sheeting and bracing shall be left in place until the trench has been backfilled one foot above the top of the pipe. (d) Sheeting, shoring and bracing shall be considered as an integral part of the excavation work and no specific payment will be allowed therefor. 1.07 Dewatering Excavated Areas (a) The Contractor shall provide and maintain ample ecuipment with which to remove all water from every source which enters excavations for structures and pipelines. Dewatering operations shall ensure dry excavations and the preserva- tion of the elevations of the bottoms of the excavations shown. on the plans. (b) Surface drainage shall not be allowed to enter excavated areas. (c) Where the areas to be excavated are located under water surfaces or near the banks of flowing streams or other bodies of water, the Contractor may adopt and carry out any method of dewatering he may deem feasible for the per- formance of the excavation work and for protection of the work thereafter; pro- vided that the method and equipment to be used results in completed work which complies with the specifications and is acceptable to the Engineer. In such cases, the excavation area shall be effectively protected from water damage during the excavation period and until all contemplated construction work therein has been completed. (d) Prior to beginning excavation for structures which are to be construc- ted at or below the 7roundwater table, groundwater levels shall be lowered and ma_-n::a ne' a= a level at least three (3) feet below the bottom such structures until construction and backfilling operations have been completed. le) The Contractor shall be responsible for damage to structures caused by hydrostatic displacement during construction operations. (f) The cost of all temporary construction work necessary or incidental to dewatering excavated areas, including the costs of placing and removing sand bags, coffer dams, sheet piling, excavation and backfill, pumping, dewatering and well pointin._,_ shall be considered an integral part of the cos` of excavation and rio separate DavMe.,IZ will be made therefor. 8 - 1 - 4 i I (g) The Special Conditions may contain additional requirements for dewat- ering excavated areas. 1.08 Fills and Embankments (a) Fills and embankments shall be constructed of rolled or compacted earth conforming to these specifications and to the lines and grades shown on the drawings. (b) The area to be occupied by the embankment shall be stripped of all surface material to a depth of not less than 6-inches and this material shall be removed and stockpiled for reuse as topsoil as specified elsewhere. The surface thus exposed shall then be machine-graded to planes suitable for embankment foundations. Any materials such as large stones or stumps found embedded in the exposed surface that would interfere with proper compaction and consolidation of the starting layers of embankment shall also be removed. Any material thus removed from the embankment area which is unsuitable for embankment construction shall be disposed of in a suitable manner and shall not be used in the work. (c) Material used for embankment construction shall consist of a mixture of the available soils. It shall be entirely free of brush, stumps, heavy sods, heavy growth of grass and other organic matter and shall not contain any stones larger than 5-inches in greatest dimension. Material shall be placed in the embankment in successive layers of not more than 12-inches in loose depth and then rolled and compacted as specified herein. Starting layers shall begin at the lowest points in the fill. All starting layers shall be carefully placed and compacted in such manner as will provide a complete bond between the compacted fill and the natural ground on which it rests so as to prevent the development of planes of weakness. Successive layers shall be approximately horizontal after compaction, and shall be sloped slightly to the outside edge of the fill to provide proper drainage while the work is in progress. Material for successive layers may be dumped onto preceding layers; but it shall then be spread, by the use of blade graders, bulldozers or similar equipment, so that when properly compacted it will form a layer of uniform thickness over the entire preceding layers. .d) The materials shall be distributed and mixed in eac:. ''aver so that all parts cf the finished embankment will be a uniform composite mixture of all of the w.-Liable soils, and will be free of lenses, pockets, streaks or layers which :iffer materially in texture or density from adjoining lavers. No pockets or clusters of stones shall be permitted to form in the completed work. le) The moisture content after compaction shall be as uniform as prac- ticable throughout any one layer of fill material. The moisture content after compaction shall be within the limits of 2.5 percentage points above optimum and 1.5 percentage points below optimum moisture content as determined by ASTM Speci- f:cation D698. Material that is too wet shall be spread on the fill and per- mitted to dry, assisted by discing or harrowing, if necessary, until the moisture content is reduced to an amount within the specified limits. When the material is too dry, the Contractor will be required to sprinkle each layer on the fill. Harrow?ng, or other authorized methods will be required to wore: the moisture into the ma-erial until a uniform distribution of moisture is obtained. Water applied o-: a - _yer of fill shall be accurately controller' in amount s.. that free water appear or. the surface. during or subsequent: `o roi' Should too muc;: e_ added an, pa-- of the ___i surface, _;:D tha- .._._..a:. is too we. ot.:'_n the desired compaction, :he rollins on that sec`io;-. -he fill shalt. oe de'Ldved until the moisture content of the material is reduced to an amount within the specified limits. If it is impracticable to obtain the specified moisture content by wetting or drying the material on the fill, the Contractor mav_ be required to prevent or dry back the material at the sources of excavation. :after the material has been properiv spread in '__v-ers, shall then o: ?_.ted b ..-ac~or shee, , fo,_: ro_ie_ -.. pes of tam - l is unde _ I , structures shall be compacted to 100% of the maximum dry density and fills under driveways and access roads shall be compacted to 95% of the maximum dry density. Other fills shall be compacted to 92% of the maximum dry density. Compaction test results shall be compared to the Maximum Dry Density obtained from the compaction test by Method A of ASTM Specification D-698-58T for the type soil tested. Field density tests shall be made to determine the compaction of the fill. These tests shall be made in accordance with the provisions of ASTM Speci- fication D-1556-58T. These tests shall be made at depths of from 6 to 12-inches below the surface of each fill layer. Fills under structures shall be tested at the rate of one test per 2,500 square foot per l'-6" of fill constructed. Fills under driveways and access roads shall be tested at the rate of one test per 5,000 square foot per 1'-6" of fill constructed. Other fills shall be tested at the rate of one test per 10,000 square foot per three feet of fill constructed. The number of passes of the roller required to obtain the desired density shall be as designated by the Engineer. In no case shall material for a following layer be placed until rolling operations have continued long enough to produce the required density. Earth-moving equipment may be routed over the work to assist in compaction. (g) The Owner will provide the services of a field technician of a rec- ognized commercial testing laboratory during the construction of the fills to make density determinations. The field technician shall report the test results to the Contractor and Engineer on the project site as soon as these results are known. The results of all density tests shall be reported in writing and shall include the date of test, test location, depth below finished grade, wet density, moisture content, dry density, percent compaction of test sample, and maximum dry density used for comparison. (h) The slopes and the top of the fill shall be carefully trimmed so that after making proper allowance for shrinkage they will conform to the slopes and dimensions called for on the drawings. No material shall be left on the outside surfaces of the fill which is at a steeper slope than that shown on the drawings. (i) Fill around pipes, conduits, and structures shall be clean, selected material spread in layers 6-inches thick and compacted with approved mechanical tampers. (j) The number, type, size and operating conditions of all equipment used in the work shall be suitable for the work to be performed. Any unsuitable or inadequate equipment shall be replaced. 1.09 Borrow Excavation (a) Wherever the backfill or embankment requires a volume of material that is in excess of the volume of suitable material available from the authorized excavations, such excess volume shall be obtained from other sources. Where borrow pits on the construction site are specifically designated on the plans, borrow excavation shall be obtained therefrom; otherwise, the Contractor shall provide suitable borrow material from areas accessible to the work. Before a borrow pit is opened the quality and suitability of the material to be obtained therefrom shall be approved by the Engineer. (b) Borrow pits shall not be opened until the original surface has been cross-sectioned so that the volume of material removed therefrom may be accur- ately determined at anv time as the work progresses. Borro•.a pits shall be roper: cleared and grubbed and all objectionable matter sha:_ be removed from the borrow pit material prior to its placement in the backfil1s. (c) Borrow pits shall be excavated so that the remaining surfaces and slopes will be reasonably smooth and even and will provide adequate drainage over the entire area. Drainage ditches shall be constructed where necessary to pro- vide outlets of water to the nearest natural channel so that the formation of pools in the borrow pit area will be avoided. Sides of borrow pit cuts shall be left ar-. two on one slope unless otherwise authorized by the. Engineer. d) in unit price contracts, materia'_s taken from borrow bits and used in S - 1 the construction of backfills or embankments shall be classified as common ex- cavation. 1.10 Rock Excavation (a) The removal of sound, solid rock of whatever nature which occurs in its original position in ledges, bedded deposits or stratified and unstratified masses within the excavation limits shown on the plans, and which is of such hardness or texture that it cannot be loosened, or broken down and removed with- out resort to drilling and blasting methods, shall be classified as rock excava- tion. Likewise, the removal of boulders, pieces of stone and old masonry masses one cubic yard or larger in volume shall be classified as rock excavation. (b) The removal of hardpan, chert, clay, soft or disintegrated shale, and of other rock materials and boulders less than one cubic yard in volume, shall not be classified as rock excavation although the Contractor may elect to ex- cavate same by drilling and blasting methods. The excavation and removal of all such materials shall be classified as common excavation. (c) The removal of existing pavements, sidewalks, driveways, manholes and similar structures called for on the plans shall be performed under these speci- fications and shall not be classified as rock excavation. 1.11 Inspection of Rock Surfaces (a) Where rock is encountered in the process of excavation within the excavation limits shown on the plans, or specified herein, it shall be completely uncovered and stripped of all loose material over the entire area, if for a structure, and over a trench length of not less than 50-feet, if for a pipeline; and all such loose material shall be disposed of as herein provided. The Engi- neer shall then make a detailed examination of the exposed rock surface and shall take surface elevations and measurements as may be necessary to determine ulti- mately the volume of rock excavated. All material removed from the area prior to examination and authorization by the Engineer shall be considered as common excavation. 1.12 Rork in Pipe Trenches (a) Rock encountered in trench excavation for sewers and other pipelines shall be removed for the overall width of trench which shall be as shown on the plans. It shall be removed to a minimum depth of six (6) inches below the bottom of the pipe. At bell holes, rock shall be removed to a minimum depth of six (6) inches below the bottom of the bell. Where pipelines are constructed on concrete cradles, rock shall be excavated to the bottom of the cradle as shown on the plans. (b) After the Engineer has examined the completed excavation, and has taken the necessary measurements for volume determination, the space below the ultimate pipe grade shall be filled with pipe embedment materials as required, compacted to proper grade and made ready for pipe laying. :.13 Drilling and Blasting Dri:iing and olasting methods used in roc'rc excava-_ icn shall be or- 'ional pith the Contractor but shall be conducted with due regard to the safer-- of persons and property in the vicinity of the work and in strict conformity with all laws, ordinances or regulations governing blasting and the use of explosives. Rock excavation near existing structures of all types shall be conducted with the utmost care, and every precaution shall be taken to prevent damage to such struc- tures. Any damage or 4-:,jury of whatever nature to persons or property cause(! !irect:: or indirect_ blasting opera:ions shat: be prorot_ repaired, re laced . _ :ompensatec! fc-_- by the "ontractor a` .. ?-w-n expense a?' ~o the ent :. satisfaction of the persons injured or the owners of the property damaged. (b) Where future units are adjacent to structures requiring rock excava- tion, the rock shall be drilled and blasted (not excavated) for a distance of approximately 10-feet from the present construction, as shown on the plans or as authorized by the Engineer. 1.14 Backfilling Trenches (a) The backfilling of pipeline trenches shall be started immediately after the pipe work has been examined and accepted by the Engineer. The initial backfill material (above pipe embedment materials), placed to a height of one (1) foot above the top of the pipe, shall consist of fine-loose earth, free of large clods, stones, vegetable matter, debris, and/or other objectionable material. It shall be carefully placed and loosely compacted unless thorough compaction of the entire backfill is required as specified in Paragraph 1.15(d) hereof. The re- mainder of the backfill shall be the same type material except that a broken stone content of not more than fifty (50) percent by volume will be allowed of stones not exceeding six (6) inches maximum dimension, provided that these stones are thoroughly mixed with earth. (b) Where the trench extends along or across streets, roadways, usable alleys, or sidewalks the trench shall be completely backfilled (above pipe embed- ment materials) with either compacted earth or Type I crushed stone. Unless otherwise specified in the Special Conditions or shown on the plans, such tren- ches shall be backfilled with compacted earth. Earth backfill shall be as speci- fied in Paragraph 1.14(a) hereof and shall contain no rock. Earth shall be de- posited in 6-inch layers (before compaction) and thoroughly compacted with power tools. Type I crushed stone shall be as specified in Paragraph 1.15 of these specifications. (c) Where excavation has been made within the limits of easements across private property, the top one (1) foot of backfill material shall consist of fine loose earth free from large clods, vegetable matter, debris, stones, and/or other objectionable materials. (d) Where trenches are not under pavement, sidewalks, or in alleys, the backfill material shall be neatly rounded over the trench to a sufficient height to allow for settlement to grade after consolidation, Any deficiency in the quantity of materials for backfilling the trenches, or for filling depressions caused by settlement, shall be supplied by the Contractor. (e) Where pipe trenches are cut across or along pavement and the trench backfill is compacted earth, the Contractor shall construct a temporary surface over the cut by filling and tamping the upper 6-inches of the trench with se- lected gravel or crushed stone which will not disintegrate under traffic and which shall be maintained in good condition under traffic until the permanent pavement has been constructed. Where pipe trenches are cut across or along pave- ment and the trench backfill is crushed stone, the Contractor shall construct a temporary bituminous pavement surface over the cut which will not disintegrate under traffic and which shall be maintained in good condition under traffic until the permanent pavement has been constructed. No separate payment will be made for temporary surfacing, (f) Backfilling around structures shall be done in the ;Wanner specified above for pipe :Tenches by power tamping for the full depth. ?f cut from the bo::tom o_` the f_nished grade. ) Al'- backfilling shall be done in such manner as will not disturb or injure the pipe or structure over or against which it is being placed. Any pipe or structure injured, damaged or moved from its proper line or grade during backfilling operations shall be opened up and repaired and then re-backfilled as herein specified. (h) The Contractor shall replace all surface materials and shall restore pavin?, curbinF,, sidewalks, gutters, shrubbery, fences, sod, ant' other surfaces iis-u='oec?, to a condition equal to that before the work began, furnishing al:. 8 - i - 8 labor and materials incidental thereto as provided elsewhere in these specifica- tions. 1.15 Crushed Stone (a) Crushed stone shall be limestone, granite or other suitable types and shall be Type I or Type II. (b) Type I crushed stone shall be well graded crusher-run stone having a maximum size of lh-inches. Type I crushed stone shall be used to backfill pipe- line trenches when specified in the Special Conditions or where shown on the plans. (c) Ty2e 11 crushed stone shall be sized so that 100% passes a lh" sieve, 95-100% passes a 1" sieve, 25-608 passes a h" sieve, 0-108 passes a No. 4 sieve, and 0-58 passes a No. 8 sieve. Type II crushed stone shall be used under struc- tures when specified in the Special Conditions or where shown on the plans. (d) Crushed stone shall be handled on the job in such manner that it will be kept clean and free from dirt, clay, and other foreign matter. Crushed stone shall be thoroughly compacted with power tools. 1.16 Pipe Foundation Material (a) Pipe foundation material shall be quarry run crushed limestone or granite ranging in size from fines to a maximum size of six (6) inches. The material shall be power tamped in six (6) inch layers. (b) Pipe foundation material shall be used in local areas where unsuitable materials such as muck, quicksand, soft clay, or swampy material make it neces- sary to provide a satisfactory pipe foundation. (c) Pipe foundation material used as described above will be measured for payment only in specific locations where its use is authorized in writing by the Engineer before this work is performed. 1.17 Pipe Embedment Materials a) Pipe embedment materials for PVC plastic sewer pipe shall be Class I, or or Class III. Where rock is removed from the pipe trench, where run- ning water is encountered in the trench, or where the trench depth is 20-feet, or greater, Class I material shall be used for bedding and haunching up to the pipe spring line. 'N'here Class I material is used for bedding, it shall also be used for haunching up to the pipe spring line. Where Class I material is used on pipes installed below groundwater levels or where the trench is subject to inun- dation, Class I material shall be placed to the top of the pipe. Class I materi- als shall be graded crushed limestone, or granite, ?»" to lk" in size. Class II materials shall be coarse sands and gravels with maximum particle size of lL" including variously graded sands and gravels containing small percentages of fines, generally granular and non-cohesive, either wet or dry. Class III materi- als shall be fine sand and clayey gravels, including fine sands, sand-clay mix- tures, and gravel-clay mixtures. (b) Class I materials when placed in the pipe trench do not require com- pdctior.. Class II materials shall be compacted to a minimum 85 percent Standarc'. pct Density. Class III materials shall be compacted to a minimum 90 percen-_ and: Proctor Density. Where Class II and III materials are used, the Cot- - `_-3cto_ shall provide mechanical tampers and equipment to regularly test t,:- degree of compaction. (c) Where pipe embedment materials for vitrified clav. concrete, and dt.cctilr iron sewer pipe and ductile iron water pipe are required by the plans, it shall )e Class IV. Class IV materials shall be graded crushed limestone or :.:'ani,::?. :o 3/1:" in size. Class IV materials shall be mec:?anically tamped. .'.1 :";)e embedrner:? materials shall be placed to suppo:= ;he full length o: >ar::ei c_ the p_ e a`. exact line and grade. (e) Pipe embedment materials shall be placed in the pipe trench to the trench width and depth shown on the plans. Where rock has been removed from the pipe trench, it shall be placed to a minimum depth shown on the plans. 1.18 Dumped Rip-Rap (a) Dumped rip-rap shall be Type I or Type II as shown on the plans. All rip-rap shall be of field stone or quarry stone insoluble in water and generally rectangular in section. Rip-rap shall be dumped in place in such a manner as to produce a reasonably well graded mass. Dumped rip-rap shall be placed to the dimension shown on the plans. (b) Type I rip-rap shall be sized so that 50 percent of the stones are not less than six (6) cubic feet nor larger than nine (9) cubic feet. Other stones shall range in size from one (1) to five (5) cubic feet. (c) Tyne II rip-rap shall consist of well graded stones weighing from 10 to 200 pounds each, with at least 50 percent weighing over 80 pounds each. Both width and thickness of each stone shall be at least one-third (1/3) its length. Not more than 10 percent by total weight shall weigh less than 10 pounds each and not more than 10 percent by total weight shall weigh more than 200 pounds each. 1.19 Disposal of Materials (a) All materials removed by excavation which are suitable for the purpose shall be used whenever practicable for fills, embankments, backfilling pipe trenches, and for such other purposes as may be shown on the plans or authorized by the Engineer. All materials not used for such purposes shall be considered as waste materials and disposed of by the Contractor. (b) Waste materials may be deposited in spoil banks on the site of the work if space is available. Such on-site spoil bank locations shall be author- ized by the Engineer. Waste materials shall not be left in unsightly piles but shall be spread in uniform layers and neatly leveled and shaped. Spoil banks shall be provided with adequate openings to permit surface drainage of adjacent lands. Where on-site disposal is not practical, the Contractor shall be respons- ible for off-site disposal. (c) On completion of any part of the work proper disposal shall be made of all surplus or unused materials within the construction limits of such work and the surface of the work left in a neat and workmanlike condition. (d) Disposal of excavated materials shall be considered an integral part of the excavation work and no separate payment therefor will be allowed. 1.20 Foundation Drilling (a) When the excavation for foundations for buildings, tanks and other major structures is completed, the Contractor shall test drill these foundations. Where the foundation is in rock, test holes shall be drilled to a depth of not less than 6-feet below grade. In earth, holes shall be drilled to rock and 6- feet into such rock, except that no holes will be required to be drilled deeper than 15-feet below grade. Holes shall be spaced approximately; 25-feet apart. Should such drillings indicate the presence of cavities or other unsatisfactory foundation conditions; such areas shall be excavated as authorized by the En- gineer. Any such excavation authorized 'tv the engineer wil_ --e measured for payment. 1.21 Maintenance (a) All excavated areas, backfills, embankments, trenches and access roads, grading and ditches shall be maintained by the Contractor in good condi- tion pit all times until final acceptance by the Owner. `;here trench backfill has settles, trenches shall be re-backfilled. 8 - _ - _` 1.22 Special Conditions (a) The Special Conditions may contain specifications regarding the use of crushed stone and construction methods for any unusual excavation work not in- cluded in the above specifications. 1.23 Determination of Pay Quantities (a) The volumes of common and rock excavation work performed by the Con- tractor and accepted by the Engineer for which payment will be allowed shall be expressed in cubic yards and computed by the average end area method from cut measurements taken to the nearest one-tenth foot. For site grading, access roads and borrow pits such volumes shall be based on cut measurements taken from actual cross-sections of the site made prior to and after completion of the excavation. For structural excavation such volumes shall be based on the allowable horizontal excavation area as set forth in Paragraph 1.04(b) of these specifications and shall be computed from vertical and horizontal dimensions of the structure as shown on the plans and the elevations of the original ground, or in case of rock excavation, the top of the solid rock. (b) Excavated materials used in making fills or embankments shall be measured and paid for as excavation and the fills or embankments to be construc- ted shall not be measured for payment. (c) For trench excavation the allowable volume of rock excavation shall be computed from the length and width of the trench and the depth of the trench from the top of the rock measured along the center line of the trench to the bottom of the trench, or to the bottom of the rock if it is above the bottom of the trench. This depth to the bottom of the trench shall include the depth of embedment materials to be provided under pipes. The trench width and depth used to compute trench rock excavation volumes shall be as shown on the plans. (d) Over-cutting of slopes or grades, or excavation beyond the vertical or horizontal limits stipulated herein, shall not be allowed in determining the allowable volume of excavation; except where, in specific cases approved by the Engineer, the material thus produced was used as borrow material. (e) Where common and rock excavation are specific bid items and bid prices for both are provided in the Proposal, the volume of rock excavated shall be deducted from the total volume excavated in order to determine the net volume of common excavation to be allowed. (f) Where crushed stone is a specific bid item and a bid price is provided in the Proposal, the volume of crushed stone for which payment will be allowed shall be expressed in cubic yards. The volume shall be computed from the length, width/trench width, and depth of crushed stone shown on the plans, placed by the Contractor, and authorized by the Engineer. (g) The volume of pipe foundation material for which payment will be allowed shall be expressed in cubic yards. The volume shall be computed from the trench width shown on the plans, length, and depth placed by the Contractor and authorized by the Engineer. This material will not be measured for payment unless its use is authorized in writing by the Engineer before the work is per- formed. (h) The volume of dumped rip-rap for which payment will 'De allowed shall be --xvressed in cubic vards. -he volume shall be computes =com the length wid-:-., and depth of dumped ray shown on the plans, p'lacec _:ne Contractor. and authorized by the Engineer. (i) Common excavation and backfilling for pipeline trenches, manholes, inlets, valves, hydrants, and other pipe line appurtenances, will be considered as an incidental part of the work and no specific payment will be allowed there- for. i' Pipe embedment materials will be considered as an '_.._-idental part o`_ -ne we-''' and no specific pa'.me^.t ".Jill oe allo".:ed there:'.>r. 1.24 Payment (a) On unit price contracts, payment for common excavation of all classes or types under these specifications shall be made for the total allowable volume determined in the manner specified above. (b) On unit price contracts, payment for rock excavation shall be made for the quantities determined in the manner specified above for two classes of rock excavation, namely: 1. Rock Excavation - Structural and General 2. Rock Excavation - Trench (c) On unit price contracts, payment for crushed stone under there speci- fications shall be for the total allowable volume determined in the manner speci- fied above. (d) On unit price contracts, payment for pipe foundation material under these specifications shall be for the total allowable volume determined in the manner specified above. (e) On unit price contracts, payment for dumped rip-rap under these speci- fications shall be for the total allowable volume determined in the manner speci- fied above. (f) On lump sum contracts, no separate payment will be made for excavation of any type nor crushed stone, pipe foundation material, pipe embedment materi- als, and dumped rip-rap unless specified bid items and bid prices are provided in the Proposal. (g) On unit price contracts, payment will be made by the Owner to the Contractor for the quantities determined in the manner specified above at the contract unit prices listed under Item I in the Proposal, for the various types of excavation work specified herein. (h) The lump sum and/or unit price payments shall be compensation in full for furnishing all materials, supplies, and equipment, and for performing all labor and services necessary to construct the excavation, complete, as shown on the plans and specified herein. STD-EXCA.2 ROCK PAYMENT 8 - 1 - 12 ITEM II CONCRETE 2.01 Scope (a) The work covered by this item shall consist of furnishing, erecting and removing concrete forms; furnishing, proportioning and mixing concrete ingredients; and placing and finishing plain and reinforced concrete masonry; and all other work incidental thereto as required for the proper construction of the structures shown on the plans or specified herein. (b) Concrete and steel reinforcement for all classes and types of con- struction of whatever nature or location, shall be furnished and placed in accor- dance with the applicable provisions of this item, Item II. 2.02 General Requirements (a) Concrete shall be composed of cement, fine aggregate, coarse aggregate and water proportioned and mixed to produce a plastic, workable mixture. Concrete shall be either Class A or Class B, as indicated on the plans. If the class is not otherwise indicated the Contractor shall furnish Class A concrete. In general, Class A concrete shall be reinforced concrete masonry, cast-in-place in forms for foundations, footings, piers, headwalls, tanks, walls, floors, manholes, pits and similar structures; and Class B concrete shall be plain concrete and shall be used for pipe cradles, pipe protection, anchors, collars, massive sections and similar work. (b) Concrete construction shall conform to the requirements of the American Concrete Institute (ACI) Standard 304 for Measuring, Mixing, Transporting, and Placing Concrete; Standard 305 for Hot Weather Concreting; Standard 308 for Curing Concrete; and Standard 309 for Consolidation of Concrete. 2.03 Materials (a) Cement for Class A concrete shall be Portland Cement conforming to ASTM Specification C150, Type I. Added thereto shall be Master Builders Pozzolith and raster builders MB-VR, comparable additives as manufactured b.. the w. R. Grace Co. or equal. Additives shall be placed in the cement at the mixer in accordance with recommendations of their manufacturer. (b) Cement for Class 3 concrete shall be Portland Cemen.: conforming to AST". Specification C150, Type I. (c) Other type cements, when required, will be specified in the Special Conditions. (d) Fine aggregate shall be a natural siliceous and consisting of hard, durable, and uncoated particles conforming to ASTM Specification C33. It shall have a fineness modulus of from 2.40 to 3.00. Fine aggregate shall be of such quality that when made into a mortar and subjected to a mortar strength test (ASTM C87), it shall develop a compressive strength at 7 and 28 days of not less than 90 percent of that developed by a mortar prepared in the same manner with the same cement and graded standard sand having a fineness modulus o_' 2.40± 0.10. (e` Coarse aggre-zate shall consist of natural washed travel, crushed stone. .,- c:-ushed blast furnace slag conforming to ASTM Specification. C33. It shall ;rad-_'. bass square mesh screens of the following limiting, s'_tes: Class A Concrete Class 3 Concrete Minimum Screen Size No. 4 No. 4 Maximum Screen Size 3/4 Inch 2 Inches dater used in mixing concrete shall be fresh, .ear, and free fro r. _ous amou::t of cil, acid, alma:-, vereta^le, sewage and or organic matte_ 2.04 Sam2ling and Testing (a) Cement and aggregates shall be tested by a recognized testing laboratory which has been selected by the Owner. The testing laboratory shall prepare written reports of such tests which shall certify that the material covered by the report complies in all respects with these specifications. These tests and reports shall be made on each shipment of cement and on each bin or stockpile of aggregates used in the work. When aggregate is being furnished from the same source, tests subsequent to the initial tests may be suspended when specifically authorized by the Engineer. When specifically authorized by the Engineer, mill test certificates shall be submitted for cement shipments. Certified test reports and certificates shall be submitted to the Engineer in duplicate. (b) The Contractor shall determine the source, kind and quality of cement and aggregates to be used in the work well in advance of the scheduled start of the work, in order to permit proper sampling and testing. He shall be fully responsible for delays in the progress of the work due to delays in sampling, testing and reporting on cement or aggregates. No cement or aggregates shall be incorporated in the work prior to receipt and acceptance of certified test reports or certificates by the Engineer. The cost of sampling and testing cement aggregates will be borne by the Contractor. 2.05 Storage of Concrete Materials (a) Cement shall be stored off the ground in a dry, ventilated building. Storage facilities shall be provided by and at the expense of the Contractor and accepted by the Engineer prior to the arrival of the first shipment. No cement damaged by improper storage or handling shall be used in the work. (b) Sand and coarse aggregates shall be stored in stock piles at selected points to provide maximum drainage and to prevent the inclusion of any foreign material during rehandling. Stock piles shall be built on planking in 2 foot layers to avoid segregation. Sizes shall be kept separate by the use of wooden bulkheads between adjacent piles. 2.06 Proportioning (a) Concrete ingredients shall be selected, proportions' and mixed to pro- duce a workable, homogeneous concrete within the following li:?iting requirements: Class A Class B Concrete Concrete Min. Compressive Strength at 28 days 5 consecutive specimens (Lb./sq. in.) 4,000 2,000 Any one specimen (Lb./sq. in.) 3,500 1,600 Volume of cement per cu, yd, concrete Minimum (Bag) 6.0 4.5 Maximum (Bag) 7.0 5.5 Volume of water per cu. ft. of cement Maximum (Cal.) 6,0 7.50 Amount of Air Entrained in fresh mix Minimum of volume) None Maximum 3 of volume) None (b) The exact volumes and proportions of ingredients to be used in each cubic yard of concrete shall be pre-determined by the Contractor well in advance of the start of mixing operations in order to assure conform,-.,., of the resulting, concrete with the above specifications. Such pre-determination shall be made b•: .-:ixinz and testing a series of trial mixes of the actual ingredients proposed `)e _:sed, the trial mixes to be computed and designed in accordance with t.. 0 1 Portland Cement Association Bulletin ST-100, Design of Concrete Mixes. Trial mixes shall be repeated with varying proportions of ingredients until the resulting concrete meets the specified limitations. The results of such trial tests shall be reported to and accepted by the Engineer prior to the start of concrete mixing operations. (c) The amount of moisture carried on the surface of the aggregate particles shall be included in calculating the water content of each mix. In all cases, however, the amount of water to be used shall be the minimum amount necessary to produce a plastic mixture of the specific strength and of the desired durability, density and workability. The slump shall be between 3 inches and 44 inches when determined in accordance with ASTM Test C143. Concrete must be workable at these slumps. (d) The air content of freshly mixed concrete shall be determined by the appropriate ASTM Test C231. Frequency of this test will be at the discretion of the Engineer. Any concrete shown by such measurements to contain more or less air than the specified amount shall be rejected and shall not be used in the work. (e) No admixtures of hardening or curative materials shall be used unless previously authorized in writing by the Engineer. 2.07 Mixing and Transporting (a) Concrete materials shall be measured by weight. Scales suitably designed and constructed for this purpose shall be provided. Each batch of aggregate and cement shall be weighed separately. Cement in standard packages need not be weighed. Mixing water shall be measured by volume or by weight. All measuring devices shall be checked and accepted by the Engineer prior to use. (b) Concrete shall be mixed in a standard type of batch mixer with a drum speed of 200 to 225 peripheral feet per minute. Mixing time shall be one minute for batches of 1 cu, yd, or less, and shall be increased 15 sec. for each addi- tional 1/2 cu. yd. or fraction thereof. The entire batch shall be discharged before recharging. (c) Central-mixed and transit-mixed concrete may be used, providing that the qual:-,r and kind of material used and the proportioning, mixing and transportatio:-. to -e _`orms conform to the requirements of ACI Standard 30?.. 2.08 :oncrete Placement 'a) Before placing concrete, forms shall be clean and thoroughly oiled wiz:-. a non-staining mineral oil. Concrete shall not be placed until the forms and rein_`orcement have been checked and accepted by the Engineer. Unless otherwise specified, all concrete shall be placed upon clean, damp surfaces, free from water, and never upon soft mud or dry porous earth. (b) Chutes shall be used to place concrete only when specifically authorized by Engineer. When permitted, metal or metal lined chutes shall have rounded bott_:-s, with end baffles and shall be sloped to insure continuous flow of concrete wither segregation of aggregates. Tremies, bottom dump buckets, or concrete buggies shall be used whenever practical for depositing concrete. C) Concrete shall be deposited as close as possible to its final positic: _n `Dr-ns. The depositing of concrete shall be regulated so that the concre-- na e `ec-ive' compacted with a minimum of lateral me•:ement into horizon:-..: . -a,,:---s pproximateiv '_ ` inches in thickness. Concrete shall be worked into .__ or. _s and angles and around reinforcemer.t and embedded "_%zures in such mantle as fill all voids, prevent honey-combing against the forms, and preven- segregation of coarse aggregate. This operation shall be performed by the use of spades or forks, or by other approved methods. Rakes shall not be used. d) During placing operations, concrete shall not be allowed to drop freei grea-er than 5 feet. When :oncrete is place: vertical distan.- -e3_-. an ,e- narrow wall ?jrms. meta'_ droL c....-a w _th ton hopve. o-::er .i:.ceo-able placing methods shall be ise (e) Concrete shall be compacted with mechanical vibrating equipment sup- plemented by handspading and tamping. Vibrators shall not be used to transport concrete inside the forms. Vibrating equipment shall be of the internal type and shall at all times be adequate in number of units and power of each unit to properly consolidate all concrete. Form or surface vibrators shall not be used. Internal vibrators shall maintain a frequency of vibration of not less than 3,600 per minute when submerged in the concrete. Vibrators shall not be left stationary in any position, but shall be moved continuously from point to point in a slow and steady movement. Vibration shall be held to a minimum to avoid loss of air content after concrete has been placed in the forms. (f) Water accumulated during placement shall be immediately removed. Under no circumstances shall concrete be placed in such accumulations. (g) Before depositing new concrete on or against hardened concrete, the surface of the hardened concrete shall be thoroughly roughened, cleaned, and saturated with water. The surface shall then be coated with grout against which the new concrete shall be placed before the grout has attained its initial set. (h) All top surfaces not covered by forms and which are not to be covered by additional concrete or backfill shall be carried slightly above grade and struck off by board finish. (i) Freshly placed concrete shall be protected from wash by rain, flowing water, mud deposits and other injurious conditions. Concrete shall not be allowed to dry out from the time it is placed until the expiration of curing period. 2.09 -Curine and Protecting Concrete (a) All concrete shall be cured by the use of wet burlap or by a liquid membrane curing compound. Wet burlap shall he used where concrete is to be painted, topped with grout, and where concrete is to receive tile or a covering which requires an adhesive. Burlap so used shall be kept continuously wet for a period of seven (7) days, Liquid membrane curing compound shall be Sonneborn- Contech Hydrocide Resin Base Compound with fugitive red tint, Lambert Corporation No. 64 - WB Compound with fugitive red tint, or approved equal. Curing compounds shall comply with ASTM Specification C309, Type 1 and AASHO Specification M148, Type 1 and shall be applied to concrete at a rate recommended b; the manufacturer. (b) In cold weather concrete shall be mixed and placed only when the temperature is at 400F, or above, and rising, unless specifical'-; authorized by the Engineer, in which event all materials shall be heated in a manner acceptable to the Engineer. In freezing weather, suitable means shall be provided for maintaining the concrete at a temperature of at least 50°F. for a period of not less than 72 hours after placing, or until the concrete has thoroughly hardened. Salt, chemicals or other foreign materials shall not be mixed with the concrete for the purpose of preventing freezing. Concrete temperature shall not be allowed to exceed 900F, during pouring operations or for 72 hours hereafter. 2.10 Finish (a) All permanently exposed concrete surfaces, except slabs, shall be given a rubbed finish consisting of filling small voids and two rubbings. Plastering and steel troweling of surfaces will not be permitted. Concrete surfaces to be rubber shall include, but shall not be limited to, (i) 3asin exterior and 'nterior wall- above ground and water levels; (2) Exterior waLs of pumping stations above grounc. level; (3) interior walls of pumping station dry wells above and below ground leve' (including stairs); (4) Interior walls of pumping station wet wells above water level; (5) Exterior and interior walls of screen chambers above ground and water levels; (6) Exterior and interior walls of sludge drying beds above ground and filter media levels; (7) Exterior walls of meter and valve pits above ground level; (8) Exterior walls of building foundations above ground level; ?) Exterior walls of submersible pumping stations above ground level; and E:terior walls o: wa:e_- _eser,.oir foundations above ground level. 0 1 (b) Immediately after the removal of forms and steel ties, small voids shall be filled with mortar (1 part cement, 2 parts sand), pressed into holes, and floated smooth. Imperfect surfaces shall not be patched but shall be removed and replaced. (c) The initial rubbing of concrete shall begin immediately after concrete surfaces have been floated smooth and the pointing has set. The initial rubbing shall be with a No. 16 carborundum stone which shall be continued until all burrs, form marks, and irregularities have been removed. The concrete shall be cured for a minimum of seven (7) days, beginning immediately after the initial rubbing. After at least seven (7) days curing, the final rubbing shall be with a No. 30 carborundum stone which shall be continued until all swirl marks and surplus materials have been removed from the surface and the surfaces show a uniform, smooth finish and uniform color. (d) No special concrete or cement mortar topping course shall be used for slab finish unless shown on the plans. The base slab shall be brought to a true and even finish by power or hand floating. Where a trowel finish is required as shown on the drawings, it shall be done with steel trowels in such a manner as to produce a dense, smooth, impervious surface, free from blemishes. 2.11 Forms (a) Forms shall be of wood, steel or other authorized material. Where feasible, steel slip forms for continuous concrete placement may be used, subject to prior authorization by the Engineer of the materials to be used. Unless otherwise authorized, the form sheeting against permanently exposed concrete surfaces shall be either steel or plywood of the necessary strength. (b) Forms shall be built true to line and grade, and shall be mortar tight and sufficiently rigid to prevent displacement, or sagging between supports. Form surfaces shall be smooth and free from irregularities, dents, sags, or holes. Bolts and rods used for internal ties shall be arranged so that, when the forms are removed, no metal will be less than 1 inch from any concrete surface. (c) Forms shall not be removed without the authorization of the Engineer. Remo-:al shall be accomplished in such manner as will prevent injurv to the con- crete. Forms shall not be removed before the expiration of the following minimum number of days after placement of concrete. Slabs 14 days Monolithic Pipe 7 days Columns and Walls 2 days Other Concrete 2 days (d) All exposed concrete edges shall be given a 3/4 inch chamfer unless other size chamfers are shown on the plans. Chamfers shall be formed by properl_: sized strips secured to the forms. 2.12 Joints (a) Construction joints and expansion and contraction joints shall cons'ructed only at locations shown on the plans, unless otherwise authorized :::-:e Engineer. Concrete at all joints shall have been in place not less than. hc_?rs before concrete is placed on or adjacent to it. The joints shall be strai,:n- and e:cactly horizontal or vertical as shown cn the plans. When shown on the plans. molded water stops shall be used in construction joints and expansion and contraction joints. Molded water stops shall be of rubber or polyvinyl chloride composition. (b) Molded rubber water stops for construction joints shall be the flac t_rte '..aches in length, -with a 3/,+ inch bulb at each end. `folded rubber wat:•_ ,tocexpansion and ontractio joints shall be the _lat type, 9 inches :eng--, ?_t.. a in h bulb at each .nd and a l? inch hollow 'bulb in the centet Splices in rubber water stops shall be made by vulcanizing or by the use of a rubber union and rubber cement. Molded rubber water* stops shall be as manufactured by A. C. Horn, W. R. Meadows, Inc., Rubber & Plastics Compound Co., or equal. (c) Molded polyvinyl chloride water stops for construction joints shall be the flat type, 6 inches in length and 3/8 inch thick, with a 3/4 inch bulb at each end, as manufactured by A. C. Horn, or the flat type 6 inches in length and 3/8 inch thick with end and intermediate ribs, as manufactured by Vulcan Metal Products, Inc., A-H Products, Viveflex Corporation, or equal. Molded polyvinyl chloride water stops for expansion and contraction joints shall be the flat type, 9 inches in length and 3/8 inch thick, with a 1 inch bulb at each end and a 14 inch hollow bulb in the center, as manufactured by A. C. Horn, Vulcan Metal Products, Inc., A-H Products, Viveflex Corporation, or equal; or the flat type 9 inches in length and 3/8 inch thick, with end and intermediate ribs and center hollow bulb as manufactured by Vulcan Metal Products, Inc., A-H Products, Viveflex Corporation, or equal. Splices in polyvinyl chloride water stops shall be made by the heat-softening process in strict accordance with the manufacturer's recommenda- tions. (d) In expansion and contraction joints, premolded joint filler and cold applied joint sealing compound shall be applied to the opening on both sides of the molded water stop. Cold applied joint sealing compound shall be applied to the opening at the top of the molded water stop. Premolded joint filler shall be Self-Expanding Cork, Code 4324, and cold applied joint sealing compound shall be Vertiseal (light gray), a polysulfide polymer, both as manufactured by A. C. Horn, or shall be comparable products as manufactured by W. R. Meadows, Inc., Rubber & Plastics Compound Co., or equal. 2.13 WaterDroofin (a) Waterproofing materials of the paint and/or membrane types shall be applied to concrete structures at the locations shown on the plans. (b) Waterproofing paint and its application shall be as shown on the plans or as specified in the Special Conditions. (c) Membrane type waterproofing shall consist of four coats of hot applied waterproofing pitch and three layers of No. 15 tarred felt, or one coat of cols applied setting cement and one layer of synthetic sheeting. Pitch and felt shall be as manufactured by the Barrett Division, Allied Chemical Coro.; the Flintkote Co.; Johns-Manville; or equal. Cold applied cement shall be Nerva-Plast and synthetic sheeting shall be Nervastrol Seal-Pruf H-D, as manufactured by Rubber & Plastics Compound Co.; comparable materials as manufactured by Carlisle Tire & Rubber Division, Carlisle Corp.; Building Products Division, American Cyanamid Co.; or equal. Membrane waterproofing shall be applied in accordance with the manufacturers' recommendations and as authorized by the Engineer. 2.14 Test Cylinders (a) During concrete placement operations the Contractor shall make test cylinders, generally three cylinders for each major pour or day's operations, or on large pours every 50 cubic yards of concrete poured. The test cylinders shall be placed in a protected spot immediately after molding and kept under moist curin_ conditions for 2=: hours, and then removed to the testing laborator-:. The cost providins c:?,linder molds, storing, transportation, handlins, and testing `.._ cylinders will be borne by the Contractor. Samples shall be taken and test speci mens prepared in accordance with the requirements of ASTM Specification C31, and shall be tested in accordance with the requirements of ASTM Test C39. One cylinder shall be tested at 7 days and two cylinders shall be tested at 28 days for each major Dour or day's operation unless otherwise authorized by the Engineer. ?r. addition, one cylinder shall be tested at 56 days in the event that the 28-day tes` _aifs =. meet the requirements of the specifications. Slump and. air content tes-_ snaf: ?e made at the time samples are taken for each set of :finders. Tes results shall be reported to the Engineer in writing and shall include the date and location of the pour from which the samples were taken. 2.15 Unapproved and Damaged Work (a) On concrete work where samples failed to show proper strength or where the quality of the concrete is otherwise questionable, the Contractor may be directed to obtain cores for further testing. Such cores and tests shall be at the Owner's expense. (b) Unapproved or damaged work shall be satisfactorily replaced by the Contractor in accordance with the requirements of the plans and specifications. Removal and/or replacement of concrete work shall be done in the manner that will not impair the strength of the structure. 2.16 Steel Reinforcement Materials (a) Reinforcement bars shall conform to the requirements of ASTM Specifi- cation A615 Grade 60 or ASTM Specification A616 Grade 60. Bars shall be deformed in accordance with the requirements of ASTM Specification A615. Steel mesh reinforcement shall be electrically-welded cold drawn mild steel fabric conforming to the requirements of ASTM Specification A185. (b) Prior to the placing of any steel reinforcement in the work, written evidence shall be submitted to the Engineer to the effect that such steel has been tested under and is in conformity with these specifications unless testing is specifically waived by the Engineer. Certified true copies of test and acceptance reports by a responsible testing laboratory shall be considered as evidence of compliance. Additional tests may be required by the Engineer upon the finished bars as furnished if deemed necessary. (c) Complete detailed shop drawings, bending diagrams and schedules of the steel to be used in the work shall be submitted by the Contractor to the Engineer for review prior to the fabrication of the steel. All steel which fails to meet these specifications or which has been improperly cut or bent, or which does not conform to the sizes shown on the plans shall be rejected. (d) On deliver-; to the site of the work, the steel reinforcement shall be carefully bundled, tagged and stored in such manner that the bars for any position in the work may be readily identified. 2.17 Placing Steel (a) Before being placed in position, all steel reinforcement shall be thoroughly cleaned of oil, mill and rust scale and other coatings that would tend to destroy or reduce the bond. Where there has been a delay in depositing concrete after the reinforcement has been placed, it shall be re-inspected and re-cleaned, if necessary. (b) Reinforcement shall be accurately positioned and secured against displacement by using annealed or similar wire of not less than No. 18 gage, or suitable clips at intersections, and shall be supported by concrete or metal chairs, stays, spacers, hangers or other acceptable supports which shall have sufficient strength and stability to maintain the reinforcemen: in place throughou` concrete operations. ?c) The minimum distance between paralle' bars shat: be as shown on `. plans. Bars placed parallel to a concrete face shall be embedded in the concre?_e so as to provide a protective coating around the bars of the following minimum thickness unless otherwise shown on the plans: Slabs 1 inch Floors, walkways, drivewavs l inches malls _ _ncht,s ,earns and ,_rders-S-.irrup Seel _..chf s Beams and girders-Main Reinforcements 2 inches Columns 2 inches Footings in contact with ground 3 inches (d) Where splicing is necessary, the bars shall be lapped not less than 30 diameters, and splices shall be staggered. In all cases, the lapped connection shall be sufficient to transfer the stress between bars by bond and shear, and to develop the full strength of the bars. In slabs, beams and girders, no splices shall be made at points of maximum stress and in no case shall adjacent bars be spliced at the same point. (e) All supports and ties shall be placed in such manner that they will not be exposed on the face of the concrete nor discolor the surface of the finished concrete. Reinforcement which has been exposed for bonding with future work shall be protected from corrosion by heavy wrappings of burlap saturated with a bituminous material. (f) Movement of steel reinforcement in place during concrete operations shall be prevented. Any rods which were displaced shall be restored to proper position before they are completely covered. 2.18 Embedded Items (a) Before placing concrete, all embedded items shall be firmly and securely fastened in place. They shall be thoroughly clean and free of any coating, rust, scale, oil or other foreign matter. 2.19 Hydrostatic Testing (a) Concrete structures that are to contain water, sludge, or other liquids, such as settling or digestion tanks, coagulation basins, reservoirs, filter basins and similar structures shall be hydrostatically tested for leakage before backfilling, where applicable. Testing shall consist of filling each structure with water so that the Engineer can inspect and observe any leaks when the structure has been full of water from 24 to 48 hours. When practical, such tests shall be made before backfill is placed around the structure. All leaks in the structure are to be repaired in an approved manner. Patching or caulking or an•7 other method of repair on the outside or dry side of walls will not be permitted. Damp areas or spots on permanently exposed walls, such as in filter galleries, will be considered leaks. For structures below finished grade, hydrostatic testing may be omitted when specifically authorized by the Special Conditions. 2.20 Determination of Pav Quantities (a) On unit price contracts, the volumes of each class of concrete for which payment will be allowed shall be expressed in cubic yards as computed from the dimensions of the neat lines shown on the plans. Where concrete masonry for which specific dimensions are not given on the plans has been placed where authorized by the Engineer, the volume shall be determined by the Engineer from field measure- ments. (b) The volumes allowed for payment shall include only the items of concrete placed in accordance with these specifications and accepted b•: the Engineer. deduceions shall be made for openings in concrete for pipe or other structures tna are 'Mess than one square foot in area, for the volume of reinforcing steel embeddec'. therein, nor for fillets less than four square inches in area. (c) The quantity of steel reinforcement for which payment will be allowed shall be expressed in pounds and shall be the total weight of all bars and mesh incorporated in the work in conformity with the plans and specifications. The total allowable weight of bars shall be as determined by the Engineer using th calculated weights of bars shown on the final shop drawings. :he total allowabl- weigt:t of mesh shall be as determined by the Engineer from the average un_- weights, based on the actual weight of an area not less than 30 square feet. (d) The weight in pounds per lineal foot of each type of bar shall be computed by multiplying the theoretical cross-sectional areas in square inches (as published by the Concrete Reinforcing Steel Institute) by the factor 3.40. (e) The weight of wire, clips, ties, spacers and other fastening devices shall not be determined or allowed for payment. Splices or laps made by the Con- tractor for his own convenience shall not be allowed for payment. 2.21 Payment (a) On lump sum contracts no separate payment will be made for concrete and steel reinforcements. (b) On unit price contracts payment for Class A and Class B concrete and for steel reinforcement placed under these specifications shall be made for the quantities determined in the manner specified above at the contract unit prices per cubic yard or per pound in place for each type listed under Item II of the contract pay items. This amount, so paid, shall cover the cost of furnishing all labor, materials, tools, plant and other expenses in connection with or incidental to the concrete masonry work. STD-CONC ITEM III SANITARY SEWERS 3.01 Scope (a) The work included in this item shall consist of furnishing and in- stalling all vitrified clay, ductile iron, PVC, and precast concrete sewer pipe and fittings and the construction of all manholes and other appurtenances necessary to complete the work as shown on the plans and specified herein. (b) The work shall include all necessary excavations, embedment materials, crushed stone, and backfill as specified in Item I of these specifications and as shown on the plans. (c) Concrete work in headwalls, piers, collars, cradles, and pipe protection shall conform to and be paid for under Item II. Replacing of sidewalks, pavements, surfacings, and curbs and gutters shall conform to and be paid for under Item V. (d) Stream, highway, and railroad crossings will be considered as an inci- dental part of the work included in the unit prices for the various sizes and depths of pipe, and no specific payment will be allowed therefor unless specific designs are shown on the plans and specified in the Special Conditions and unit prices for "Crossings" are included in the Proposal. (e) On lump sum contracts no separate payment will be made for any item under Item III unless specific bid items and bid prices are included in the Pro- posal. (f) Sanitary sewers within the area to be included in Treatment Plant Piping and Pumping Station Piping or other facility piping, as shown on the plans, will not be included as a part of this item. 3.02 Sewer Materials (a) All materials used in the construction of sewers shall be new and unused when delivered to the work and shall be suitable for installation and operation under the conditions for which they are to be used. (b) All sanitary sewers fifteen inches in size and smaller shall be con- structed of either vitrified clay or PVC sewer pipe, at the option of the Con- tractor unless otherwise specified in the Special Conditions or shown on the plans. All sanitarv sewers eighteen (18) inches, twenty-one (21) inches, and twenty-four (24',,, inches in size shall be constructed of either vitrified cla•: or concrete sewer pipe, a? the option of the Contractor (1) unless otherwise specif_ed in the Special Conditions; (2) unless otherwise shown on the plans; and (:`. except that in twenty-four (24) inch size sewers in cuts deeper than sixteen and one-half (16.7) feet, vitrified clay is not acceptable and concrete sewer pipe of the class shown on the plans shall be used. All sanitary sewers larger than twenty-four (24) inches in size shall be constructed of precast concrete sewer pipe, unless otherwise specified in the Special Conditions or shown on the plans. Sanitary pipe sewers shall be constructed of ductile iron sewer pipe when shown on the plans. Casing pipes shall be installed at railroad, street, or high•.aay crossings when specified or shown on the plans. (c) All vitrified clay, concrete, PVC, and ductile iron sewer pipe and fittings shall be suitably marked at their places of manufact_,.re to show their class, -trength, or thickness, as applicable. Vitrified clay sewer nine and fit:ings shall be -ra strength" ar.ci conform to the regt:irements c. AST"l Spe._=_cat_o,. v ?Oil' _pe and fitting.; 3 ?,as in size and smaller shall have ;lain ends and shall joined by plastid sle?,., couplings or shall have bell and spigot ends joined with rubber ring gaskets. Pipe and fittings 21-inches in size and larger shall have bell and spigot ends joined with rubber ring gaskets or factory applied resilient joint material. All jointing material shall comply with the requirements of AST`1 Specification C Concrete sewer oiDe shall be tested ander and s:. ' ' comnly with th,? rc'_t llrc'-r,. .tS ,f AST%1 e:,ce,): as mod___ed ..oncrete sewe!' pipe shall be Class III unless otherwise shown on the plans. Wall thicknesses shall be "Wall B" in sizes thirty-six (36) inches in size and smaller and "Wall C" in sizes forty-two (42) inches and larger. All concrete sewer pipe shall have bell and spigot joints suitable for installation with rubber 0-ring gaskets and with a rectangular groove in the spigot end to receive the rubber gasket and contain the deformed gasket on all four sides when the joint is completed. Joints and gaskets shall comply with the requirements of ANSI/AWWA Specification C302, ASTM Specifications C361 and C443. Concrete pipe shall be cast in joints not less than 8.0 feet long. Bell and spigots shall be formed to true dimensions, with a nominal clearance of not more than 1/16-inch. Concrete used in the manufacture of pipe shall have an absorption rate not to exceed 6.0 percent. Steel reinforcement shall be circular. Materials used in the manufacture of concrete sewer pipe shall comply with the following ASTM specifications: Portland Cement C 150, Type II or C 175, Type IIA, or C 205 for Blast Furnace Slag Cement; Aggregates,' C 33 except that the fine aggregate shall be natural silica sand. Manufactured sand shall not be used. Coarse aggregates shall be crushed limestone. Each joint of pipe shall have stamped thereon the class of reinforcement and the wall thickness designation. (f) Polvvinvl Chloride (PVC) sewer pipe and fittings shall conform to the requirements of ASTM Specification D 3034. Wall thickness shall be SDR 35. Joints shall be integral bell and spigot type with compression type rubber gaskets. Saddle type fittings are not acceptable. Each joint of PVC pipe shall have stamped thereon its ASTM Specification number and SDR. (g) Ductile iron pipe shall conform to the requirements of ANSI/AWWA Specification C151/A21.51. Pressure pipe shall be designed for a minimum rated water working pressure of 350 psi in sizes 18-inches and smaller, 300 psi in 20-inch size, 250 psi in 24-inch size, and 200 psi in sizes larger than 24-inches; laying condition Type 2; and a minimum cover of 5 feet. Where the cover exceeds 5 feet, the pipe shall be designed for the actual cover installed. Non-pressure or gravity flow pipe shall have the wall thicknesses shown on the plans under "Typical Sewer Trench" details. Joints shall be "push-on" which conform to the requirements of ANSI/AWWA Specification C111/A21.11. Ductile iron fittings shall conform to the requirements of ANSI Specification A21.10, Class 350 in sizes 24-inches and smaller and Class 250 in sizes larger than 24-inches. Joints for fittings shall be mechanical joints conforming to the requirements of ANSI/AWWA Specification C111/A21.11. All ductile iron pipe and fittings s:,all have a cement mortar lining of standard thickness conforming to the requirements of ANSI/AWWA Specification C104/A21.4. (h) All vitrified clay, concrete, PVC, and ductile iron sewer pipe and fittings and materials shall be tested and inspected at their place of manufacture by the manufacturer. Manufacturer's compliance certification reports, in duplicate, shall be sent to the Engineer prior to use of the pipe in the project. (i) After delivery to the site, any materials which have been damaged in transit or are otherwise unsuitable for use in the work shall be rejected and removed from the site. 3.03 Pipe Storaze and Handlina (a) Pipe storage and handling shall be in accordance with the pipe manu- facturer's recommendations. Pipe shall be stored on a smoot'r, surface to avoid point loadings. Pipe shall be handled with care so as to prevt-. ama,Te. t7l 64 Lae Laving (a) Before sewer pipe is placed in position in the trench the bottom and sides of the trench shall be carefully prepared and the necessary bracing and sheeting installed. A mason's line shall then be tightly stretched above ground level, parallel to and directly above the axis of :he pipe to ',e installed; this ine to ire supported at intervals not exceeding, 5` feet. Th e ,Xa-- _ine and grade _o_ aac:. section. of wipe shall be determined m easurin dog«r. this line to 8 the invert of the pipe in place. Each pipe shall be accurately placed to the exact line and grade called for on the plans. The Contractor shall furnish all labor and materials necessary for erecting batter boards. Laser equipment may be used in setting pipe grades in lieu of the batter board method. When laser equipment is used, the Contractor shall check the sewer grade at intervals not greater than 50 feet with a surveyor's level which shall be provided by the Contractor. (b) Each piece of pipe and special fitting shall be carefully inspected before it is placed and no defective pipe shall be laid in the trench. Pipe laying shall proceed up-grade, starting at the lower end of the grade and with the bells up-grade. Pipe shall be straight when placed in the trench. Curved pipe shall not be laid. Trench bottoms found to be at incorrect grade after pipe laying operations have begun shall be corrected and brought to exact line and grade. Fill required shall be pipe foundation material or pipe embedment material as specified in Item I of these specifications, as applicable. (c) Bell holes shall be of sufficient size to allow ample room for properly making the pipe joints. Bell holes shall be cut not more than five joints ahead of pipe laying. The bottom of the trench between bell holes shall be carefully graded so that the pipe barrel will rest on a solid foundation for its entire length. (d) As the work progresses the interior of all pipe in place shall be thoroughly cleaned. After each line of pipe has been laid it shall be carefully inspected and all earth, trash, rags, and other foreign matter removed from the interior. (e) Backfilling of trenches shall be started immediately after the pipe is in place and the joints completed and examined and accepted by the Engineer. (f) Preparation of site, excavation and backfilling, pipe embedment, and maintenance of excavated areas shall comply with Item I of these specifications. 3.05 Joint Construction (a) Each joint shall be laid so that it will form a close concentric joint with adjoining pipe and so as to avoid sudden offsets or inequalities in the flow lines. The inside of all bells and the outside of all spigots shall be wiped to remove all dirt, water, or other foreign matter so that their surfaces are clear. and dry when the pipes are joined. (b' ) All jointing of pipe and fittings shall be in accordance with the pipe manufacturers recommendations. (c) After the joints have been completed they shall b?_ inspected by the Engineer before they are covered up. Any leaks or defects discovered at any time after completion of the work shall be repaired immediately. All pipe in place shall be carefully protected from damage until the backfilling operations have been completed. Any pipe which has been disturbed shall be taken up, the joint cleaned and remade and the pipe relaid at Contractor's expense. (d) Water shall not be allowed to run or stand in the :Tench while pipe laying is in progress or before the joints are completed or before the trench has been backfilled. The Contractor shall not open up at any time mcre trench than his available pumping facilities are able to dewater. 3.06 Deflection Tests d. ytter back-led trenches have b?.,. _ci^pleted _eas?, 30 davs, a:._ PVC sewer oiQe shall be tested for initial diametric defiecti:;:-Is by the use of . Go-No-Go type odd-numbered leg mandrel having a minimum of nine legs permanently attached. The size of the mandrel shall be based on the maximum allowable inside diameter of the pipe. The initial diametric deflection shall not exceed five percent (53). 3.07 Leakage and Infiltration (a) All pipe joints shall be as near watertight as it is practical to construct them with the material and methods specified herein. Infiltration of groundwater or other leakage into the sewer (including manholes) shall not exceed 200 gallons per mile of sewer per inch of inside diameter of the sewer per 24 hours in any section of the completed work, and in no case shall it exceed 3,000 gallons per mile per 24 hours. The infiltration into each section of the sewer shall be measured in wet weather by the temporary installation of suitable metal or wooden weirs as authorized by the Engineer. These weirs shall be furnished, installed and removed by the Contractor, any leaks into the sewer of significant magnitude that can be located shall be repaired or corrected as authorized by the Engineer regardless of infiltration test results. 3.08 Air Testing of Gravity Sewers (a) The Contractor shall conduct low pressure air tests on all completed sections of gravity sewer. Air testing shall comply with the requirements of ASTM Specification C924, except as modified herein. The air test results will be used to evaluate materials and construction methods on the sewer line sections, and successful air tests shall be mandatory for the acceptance of the sewers. (b) The Contractor shall furnish an air compressor along with all necessary plugs, valves, pressure gages, air hose, connection and other equipment necessary to conduct the air tests. Plugs in sewers shall be adequately braced for thrust reaction. (c) The sewer section shall be plugged at both ends and air pressure shall be applied until the pressure inside the pipe reaches 4 psig. When a stable con- dition has been reached, the pressure shall be bled back to 3.5 psig. At 3.5 psig, the time and pressure shall be observed and recorded. If groundwater is present at the sewer, the height of groundwater above the top of the pipe shall be added to the above air pressure readings (height of water in feet X 0.433 - air pressure in psig). A minimum of 5 readings will be required for each test. (d) If the time for the air pressure to decrease from 3.5 psig to 2.5 psig is equal to or greater than that shown in the following table, the pipe shall be presumed to be free from defect. When these times are not attained, pipe breakage, joint leakage, or leaking plugs are indicated and the cause must be determined and corrected. After repairs have been made, the sewer sections shall be retested. This process shall be repeated until all sewer sections pass the air test. Allowable Timetable Pipe Size Time Per 100 Feet Of Pipe 4" 0 min. 18 sec. 6" 0 42 8" 1 " 12 " 10" 1 It 30 " 12" 1 48 15" 2 06 " 18" -) 2 „ 21" J „ J 74i - 1: J i 217 30" 4 " 48 33" 5 " 24 " 36" 6 't 0 11 42" 7 18 48" a 0 5'1 1 ? n 4Q n b0' __ -a 3.09 Hydrostatic Testing of Pressure Sewer Pipe (a) After pressure sewer pipe has been laid, partially backfilled, and the necessary concrete thrust blocks constructed, the pipe shall be subjected to a hydrostatic pressure of 100 psi for a minimum period of two hours. (b) The pipe shall be slowly filled with water and the specified test pressure, measured at the point of lowest elevation, shall be applied by means of a pump connected to the pipe. The pump, pipe connection, gauges, meters, and other apparatus required for the tests shall be furnished and installed by the Contractor. (c) Before applying the specified test pressure, all air shall be expelled from the pipe. To accomplish this, taps shall be made, if necessary, at points of highest elevation, and afterward tightly plugged. (d) All exposed pipes, fittings, and joints shall be carefully examined during the open trench test. All leakage in joints shall be completely stopped. Any cracked or defective pipes or fittings discovered in consequence of this pressure test, shall be removed and replaced by the Contractor with sound material in the manner hereinbefore provided and the test shall be repeated until satisfactory to the Engineer. 3.10 Wves and Tees (a) Wye and Tee branches shall be placed in sanitary sewer lines at all points shown on the plans or specified herein. If such branches are not to be used immediately they shall be closed with clay, concrete, or plastic stoppers with joints as specified for the sewer pipe. (b) If the work consists of the construction of a sewer that is to replace an existing sewer all of the existing house sewers shall be connected to the new line. (c) Wyes and tees shall be placed in sanitary sewers so as to properly serve each existing house and each vacant lot facing or butting on the street or alley in which the sewer is being laid, and at such other locations as may be designated by the Engineer. The exact location of each connection shall be determined by the Engineer before backfilling. di Wyes and tees shall be of the same material and s`renz-_''r. as the sewers on which 7:hev are installed. 3.11 Connecting Risers (a) Where the depth of cut is over 8 feet or where the grade of a sanitary sewer is lower than necessary to drain abutting property, and at such other locations as may be designated by the Engineer, connecting risers shall be placed to serve each existing house and each vacant lot facing or abutting on the street in which the sewer is being laid. b) Connecting risers shall be either 4 or 6-inches in diameter constructed from a -.aye or tee connection, as shown on the plans, to the elevation designated by the -_ngineer. Connecting risers shall be vitrified clay or PVC, as applicable, and shall conform to the requirements of Paragraph 3.02 of these specifications. The w or tee connection shall be securely supported b•: a bock of concrete, s'no:VT the i ans, to suppor` -he riser '?_pe ape:' e7.ds _ netting riser a_ __osed, s hereinbefor,- specified f_. and Backfill _.. sha h e carefull-., done around these risers. 3.12 '-rouse Sewers a) House sewers shall be constructed when required in ?he Special Condi- tions _ '.when included in t'ae cOT'.trsct pay :fisted _.i rile ? ^osal, to prow.: the sal...ta'" ;eneral hou., ??? _ t_ be at the t.... f the sewer is constructed, and wyes or tees only provided for vacant lots. However, additional house sewers shall be installed by the Contractor when authorized by the Engineer. In general, house sewers shall be constructed from the lateral sewer to a point located approximately two (2) feet behind the curb line and house sewers shall not be installed where the lateral sewer is within 5 feet of the property line. (b) House sewers shall consist of either 4-inch or 6-inch diameter pipe sewers, as listed in the Proposal. House sewers shall be vitrified clay or PVC, as applicable, and shall conform to the requirements of Paragraph 3.02 of these specifications. Open ends of house sewers shall be closed as specified above for wyes and tees. 3.13 Marking Location of Wyes Tees and House Sewers (a) The location of all wyes, tees, and house sewers installed in the work shall be marked by an off-set post set in the ground. Off-set posts shall be placed at locations designated by the Engineer. Posts shall be of precast con- crete, 6" x 6" x l'-6" in size and shall have the letter "S" cast in the top. 3.14 Connections to Existing Sewers (a) Connections shall be made to all existing sewer lines in the vicinity of the work, as shown on the plans or as authorized by the Engineer. Connections shall be made into existing manholes, or by the construction of a new manhole as shown on the plans. (b) Connections to existing manholes shall be made by cutting a hole in the wall of the existing structure, inserting a length of sewer pipe into the hole, filling around same with concrete or mortar and troweling the inside and outside surfaces of the joint to a neat finish. As specified elsewhere, the bottom of the manhole shall be shaped to fit the invert of the sewer pipe. (c) Connections will be considered as an incidental part of the work and no specific payment will be allowed therefor, except where new manholes are built. 3.15 Pipe Protection (a) Sewer pipe which, when completed, will have less than Feet of cover shall be provided with Class B concrete protection, or shall be constructed of ductile iron pipe, as shown on the plans or as authorized by the Engineer. (b) Where foundation conditions are not satisfactory, as determined by the Engineer, sewer pipe shall be either laid on a Class B concrete cradle, pipe foundation material, or constructed of cast iron pipe, as shown on the plans or as authorized by the Engineer. Pipe protection, when used, will be paid for at the respective contract unit prices. 3.16 Manholes (a) Manholes shall be constructed to the sizes, shapes and dimensions and at the locations shown on the plans. Unless otherwise shown on the plans, manholes shall be four (4) feet in diameter. The height or depth of eac: manhole will vary pith the location, but it shall be such as will place the top a- -:,z finished grade the pavement or ground surface or to the elevations shorn o7 oians and the invert at the elevation design on the plans. (b) Where the difference in the invert elevation of two or more sewers 18-inches in diameter or smaller intersect in one manhole is 2 feet or more, a drop manhole shall be constructed in the manner shown on the plans. They shall be similar in construction to the standard manhole except that a drop connection of pipe and fittings of the proper size and material shall be constructed outside the manhole and supported by Class B concrete as indicated on the D'_ans. (c) Manholes shall be precast reinforced concrete pipe manhole sections with tongue and groove joints. Manholes shall conform to the requirements of ASTM Specification C 478, except as modified herein. Cement, coarse aggregate, and fine aggregate shall conform to the requirements of Paragraph 3.02(e) of these specifications for sewer pipe. Concrete used in their manufacture shall have an absorption rate shall not to exceed six (6) percent. The minimum wall thickness of the manhole riser sections shall be five (5) inches for four (4) foot diameter manholes, six (6) inches for five (5) foot diameter manholes, and seven (7) inches for six (6) foot diameter manholes. Cone sections shall have a minimum wall thickness of eight (8) inches at their top. Base riser sections shall be made with bottoms cast monolithically. Bottoms cast into already made pipe sections are not acceptable. The minimum thickness of the bottom shall be six (6) inches for manholes four (4), five (5), and six (6) feet in diameter. Suitable openings for inlet and outlet sewer pipe shall be core drilled into the base sections and into riser sections for drop connections. These openings shall be circular, accurately made, and located as required for each manhole. Base riser sections shall be set on compacted pipe embedment materials six (6) inches in thickness. Pipe embedment materials, so used, shall be Class IV or of the same type being used for pipe embedment. (d) The length of tongue and groove joints on manhole sections shall be not less than the wall thickness of the sections. The nominal clearance between tongue and groove pieces shall be 1/16-inch. The manhole sections shall be joined with "0-ring" rubber gaskets conforming to the requirements of ASTM Specification C 443. Rubber gaskets shall be installed in accordance with the recommendations of their manufacturer with the use of a suitable lubricant. A suitable rectangular recess shall be cast into the tongue of each manhole section to contain the rubber gasket such that when the joint is made, the rubber will be confined on all four sides. In addition, a flexible plastic joint sealant shall be applied to manhole section joints. The sealant shall be a factory extruded formulation of 100 percent solids with top-quality partially vulcanized butyl rubber which provides shape retention in combination with adhesion and cohesion. The sealant shall conform to the requirements Federal Specification SS-S-210A. It shall be applied to clean, dry surfaces only. Flexible manhole sle-eves or fiexi'':e "ole ntr :. e joints shall be instal_ d on all sizes and types of pipe ..anho es. Manhole sleeves shall be of high quali` syr.tilet__ ..-_ N,.ic':. _, with the ?' ar.'. Mar.ho - .tan ngs shall be requirements of ASTM Specifications C9, accurately core drilled. Sleeves shall be to the man:-.c'_e b_; Series 302, 304, or 305 stainless steel bands with sel1f-1cc':ling toggles _o make watertight unions. Sleeves shall be secured to the sewer pipe to make watertight unions by Series 302, 304, or 305 stainless steel strap clamps, draw bolts, and nuts. Flexible manhole sleeves shall be Kor-ti-Seal as manufactur b,; N.P.C., Inc. comparable manholes sleeves as manufactured b': the Press S,?a': Gasket Corp. ; or equal. (f) Manhole inverts shall be constructed of cement groin and shall have the same cross-section as the invert of the sewers -.which they connect. The manhole invert shall be carefully formed to the required s'_.e and grade ':)•: gradual and even changes in sections. Changes in direction: cf -..lough the sewer shall be mad,, to A true cure with as large radius _s = the ma: .:-.:'_l permit. tha `.,,e cast iro fOr the :OS•er sh,:__ and proper) bonde-4 to the masonry -th cement grout, ar .- :.? ru tad in pave,-. areas, the top surface of the frame and cover shall be tilted so as to conform to the exact slope, crown and grade of the existing pavement ad:acent thereto. (h) Manhole frames and covers shall be made of cast i,= conforming to the minir,,.um requirements of ASTM Specification A-- lass or ductile iro-. OI1` ::o tl` equiv ?^ents ,'f .AST`f a5 12. Al .,adr .'_.:e:._ L he sol-111C1 - e -I:. a:'.('. _..s _iclgs whi,. have been plugged or otherwise treated shall be rejected. Frames and covers shall be as detailed on the plans. The contact surfaces between the cover and its corresponding supporting ring in the frame shall be machined so that the cover will rest on the ring for the full perimeter of the contact surfaces. Castings shall be thoroughly cleaned by shot blasting and shall remain unpainted. There shall be no holes or perforations in the covers. The manufacturer's shop drawings shall be sent to the Engineer for review prior to manufacturing and shipping of castings to the job site. (i) Manhole steps shall be constructed of steel covered with rubber or plastic. Rubber or plastic covered steel steps shall consist of a ;I-inch diameter steel reinforcing rod covered by a corrosion resistant rubber or copolymer polypropylene plastic. The minimum tread width shall be 12-inches. The steps shall incorporate traction cleats and foot guide lugs. Rubber or plastic covered steel steps shall be as manufactured by Delta Pipe Products Co., M. A. Industries, Inc., or equal. All manhole steps shall comply with the requirements of OSHA. (j) Manholes for sewers 48-inches in diameter and larger shall be con- structed on reinforced concrete bases factory cast on the barrel of a joint of pipe. The design of these manhole bases shall be reviewed by the Engineer. Manhole barrels to be constructed on precast bases shall be precast concrete. Where factory cast reinforced concrete bases are used on sewers at points of alignment change, factory made bends shall be installed downstream from the manhole bases. (k) Drawings and descriptive data on manholes, rubber gaskets, joint seal- ant, flexible manhole sleeves, frames and covers, and manhole steps shall be submitted to the Engineer for review prior to their manufacture. 3.17 Work Progress and Cleaning Up (a) The project site shall be cleaned up in accordance with the requirements of Paragraph 4.5 of the General Conditions, as the work progresses. Site clean up shall not lag pipe laying more than 1,000 feet. Site clearing and grubbing shall be limited to 3,000 feet ahead of pipe laying. Pipe trenches shall not be excavated more than 300 feet in advance of laving pipe, as required in Paragraph 1.05(f) of these specifications. 3.18 Special Conditions (a) Where the work requires special stream or railroad crossings or any other extraordinary conditions, or where alternate types of construction are used that are not covered by these specifications, the materials, and construction methods shall be as shown on the plans or specified in the Special Conditions. 3.19 Determination of Pav Ouantities (a) The quantities of the various types and class of work for which unit prices are included in the Proposal that have been installed by the Contractor and accepted by the Engineer will be measured for payment in the following manner: Tvpe of Work Unit Method of :-!easurement Vitrified Clav, Lin. Ft. Horizontal :ar?th ir. ola - :neas,.red alone, Concrete, and each size, center lire ;.rite no deductic .or manholes, PVC: Sewers type, and wyes, and tees. depth of Depth measured from original ground surface cut to invert. Ductile Iron Sewers Lin. Ft. Horizontal length in place :reasured along each size center no deduc`_,.. -'or manholes, and depth and fi"._:,.?s. Depth measurer' from original of cut, ground surface to invert. Standard Manholes Each Actual number installed. Drop Manholes Each Each manhole installed with drop connection. Wyes and Tees Each Actual number installed. Connecting Risers Lin. Ft. Length in place measured along center line. each size, and type. House Sewers Lin. Ft., Horizontal length in place. each size and type. Pipe Foundation Cu. Yd. Computed from field measurements in loca- Material tions authorized by Engineer. (b) All measurements shall be made to the nearest one-tenth foot. (c) The following types of work will be considered incidental to the sewer construction and no specific payment will be allowed therefor: Earth excavation, including preparation of site, sheeting, shoring, and bracing, backfilling, disposal of surplus materials, and the maintenance of the work during construction. Rock excavation when no specific unit price is included in the Proposal for "Rock Excavation - Trench or Structural". Pipe embedment materials. Deflection tests, infiltration measurements, and air testing of gravity sewers, and hydrostatic testing of pressure sewer pipe. Connections to existing work. House sewer marker posts. 3.20 Payment (a) On lump sum contracts no separate payment will be made for any item in sanitary sewer construction unless specific bid items and bid prices are included in the Proposal. (b) On unit price contracts payment will be made by the Owner to the Con- tractor for the quantities determined in the manner specified above at the contract unit prices for the various types of work for which prices are included in the Proposal. These amounts, so paid shall be compensation in full for furnishing all materials, supplies, and equipment, and performing all labor and services necessary for constructing all of the work complete and ready for operation as shown on the plans and specified herein. STD-SAN.SEW Revised 6/11/91 ITEM IV WASTEWATER TREATMENT PLANT/PUMPING STATION PIPING 4.01 Scone (a) The work included in this item shall consist of furnishing and in- stalling all water and air piping, all valves and valve boxes, all sewers and drains, and the appurtenances incidental thereto as shown on the plans and as specified herein. (b) This item shall include all ductile iron pipe and fittings, steel, and copper pipe and fittings, valves and gates of all types, valve boxes, floor stands, hydrants, pipe supports, sewers, drains, manholes, and inlets located at the wastewater treatment plant/pumping station within the limits shown on the plans. (c) The work shall include making the necessary connections to other piping, hydrostatic testing, chlorination, painting of pipes and other miscel- laneous items. (d) The work shall include all necessary excavation and backfill as speci- fied under Item I. No specific payment will be allowed for excavation for in- stalling piping unless a specific bid item and bid price for "Rock Excavation - Trench" is included in the proposal. (e) Plumbing for buildings shall conform to the requirements of Item X. (f) Hose and plastic pipe used to convey chemical solutions shall conform to the requirements of Item IX. 4.02 General (a) All pipe, fittings, valves and other materials shall be new and unused when delivered to the work and shall be suitable for installation and operation under the conditions for which they are to be used. (b) All sewer pipe, water pipe, and all fittings shall be suitably marked at their places of manufacture to show their class or strength. (c) Detailed erection drawings for all ductile iron pipe installations shall be submitted to the Engineer for review before such materials are fabri- cated o: delivered to the work. However, review of such drawings shall not relieve the Contractor of the responsibility for the correctness of all dimen- sions and for the correct fittings of all parts of the work. (d) All ductile iron, vitrified clay, anal concrete pipe and fittings, and valves shall be tested and inspected at their places of manufacture by their manufacturers. Manufacturer's compliance certification reports, in duplicate, shall be sent to the Engineer prior to the use of the pipe, fittings, and valves in the work. (e) Any pipe or other materials which have been broken, cracked or other- wise damaged before or after delivery to the site of the work, or which have failed to meet the required tests, shall be removed from the site of the work and shall not be used therein. 4.03 Pipe Materials a) In general, metal pipe smaller -han 3-inches in diameter shall be galvanized steel and metal pipe 3-inches in diameter and larzer shall be ductile _ror.. In general, ductile iron pipe for ,inderzround work have "push-on" pints or mechanical joints and ductile iror. pipe _`or e:,:pose;- work shall have flanged ends. Unless otherwise shown on the plans, ductile iron pipe for under- ground work shall have "push-on" joints. Fittings for "push-on" joint and mechanical joint ductile iron pipe shall be ductile iron. Fittings for flanged ductile iron pipe shall be of ductile iron. The type pipe required at various locations will be shown on the plans. b) Ductile iron pipe with "push-or." -oints or mec an-cal joints shall 'onform to the -equrrements )_ :_VSI/AWW=. --ec_`_cat_oc; __.:_. The pine shall be designed for a minimum rated water working pressure of 350 PSI in sizes 18-inches and smaller, 300 PSI in 20-inch size, 250 PSI in 24-inch size, and 200 PSI in sizes larger than 24-inches; laying Condition Type 2; and a minimum cover of 5-feet. Where the cover exceeds 5-feet, the pipe shall be designed for the actual cover installed. "Push-on" joints and mechanical joints shall conform to the requirements of ANSI/AWWA Specification C111/A21.11. (c) Ductile iron fittings for ductile iron pipe with "push-on" joints shall conform to the requirements of ANSI/AWWA Specification C110/A21.10, Class 350 in sizes 24-inches and smaller, and Class 250 in sizes larger than 24-inches. Joints shall be mechanical joints conforming to the requirements of ANSI/AWWA Specification C111/A21.11. (d) Ductile iron pipe with flanged joints shall conform to the require- ments of ANSI/AWWA Specification C115/A21.15 and shall be suitable for a minimum working, pressure of 250 PSI. Flanges shall conform to the requirements of ANSI/AWWA Specification C115/A21.15. (e) Fittings for flanged ductile iron pipe shall be of ductile iron. Flanged fittings shall conform to the requirements of ANSI/AWWA Specification C110/ A21.10 and shall be suitable for a water working pressure of 250 PSI. Flanges shall conform to the requirements of ANSI/AWWA Specification C110/A21.10. (f) All ductile iron pipe and ductile iron fittings excei)t such pipe and fittings used for air piping, shall have a cement-mortar lining of standard thickness conforming to the requirements of ANSI/AWWA Specification C104/A21.4. Ductile iron pipe and fittings used for air piping shall be unlined. (g) All ductile iron pipe and ductile iron fittings which are to be painted shall be shop coated or field coated in accordance with Item VIII of these specifications. All other ductile iron pipe and cast and ductile iron fittings shall be given a bituminous coating. (h) Glass lined ductile iron Dipe shall be used for sludge and scum lines where shown on the plans and shall consist of ductile iron pipe and fittings conforming to Paragraph 4.03(-e) and (g) of these specifications, with a glassed coating fused to the inside metal base by placing the entire pipe or fitting into a furnace at the appropriate maturing temperature above 1,40007. Pipe and fit- tings shall be held at this temperature for a period of time s•`'icient to devel- op a smooth vitreous lining. The glass shall be especiall,: formulated with bond promoting constituents so that the high temperature will de-:elop a strong bond between, the glass and metal. This bond shall be sufficient -„ ermit a strain in the metal of 0.001 in./in. (the yield point of carbon steel^ ithout damage to the glass. The glass coating shall average at least 0.008 inches in thickness and shall have a hardness of approximately 400 on the Knoop scale or 5.5 on the Mohs scale. It shall be resistant to corrosion between pH3 and pH10 at 1250F. It shall withstand an instantaneous thermal shock of 300°F differential. The glass lining shall be in accordance with the manufacturer's standard tolerances for sewage sludge, continuity, and glass. Lining shall not contain pinholes, crazing, or fishscales which expose the pipe metal. Glass lined pipe shall be SG-14, as manufactured by Handler Permutit, Inc., Paramus, New Jersey or compa- rable glass lining as manufactured by Vitco Corporation, Waterford, PA, or equal. (i) Steel pipe conveying liquids shall have screwed joints and shall be standard strength unless otherwise shown on the plans. Steel .ipe shall be hot- dipped Kalvanized and shall conform to the requirements of ASY Specification A129. 7ittings for steel pipe shall be banded standard screw-?,-. _--ings made of malleable iron or cast steel. and shall be galvanized. F;,-_ s7.all be suitable for 150 PSI pressure unless otherwise shown on the plans (j) Steel DiDe convevinz bulk lime shall conform to the requirements of ASA Specification B36.10, Schedule 40. Joints shall be welded or shall be flanged when shown on the plans. Flanges shall be forged steel, 150 pound welding neck type conforming to the requirements of ASA Specification B16.5. Fittings shall be standard weight butt-welded type conforming -_ -he requirements ?f ASA Specification B16.9. Elbows shall be lonZ radius -vpe (k) Copper tubing shall be Type K and shall comply with Federal Specifi- cation WW-T-799. (1) Plastic pipe shall be high impact rigid plastic pipe, Schedule 80 Koro-seal with screwed type fittings except where flanges are shown, or compara- ble pipe as manufactured by Tube Turns Plastic, Inc., or Dow Chemical Co. (m) Sanitary Sewers shall be Service Weight cast iron soil pipe conforming to CISPI Specification HS. Joints shall be stainless steel coupling type. (n) Sewers 15-inches in size and smaller shall be vitrified clay sewer pipe. Sewers 18-inches, 21-inches, and 24-inches in size shall be vitrified clay or reinforced concrete sewer pipe. Sewers larger than 24-inches shall be rein- forced concrete sewer pipe. Vitrified clay sewer pipe shall be "extra strength" and shall conform to the requirements of ASTM Specification C 700. Pipe 12- inches in size and smaller shall have plain ends and shall be joined by plastic sleeve couplings or shall have bell and spigot ends joined with rubber ring gaskets. Pipe 15-inches in size and larger shall have bell and spigot ends joined with rubber ring gaskets or factory applied resilient joint material. All jointing material shall comply with the requirements of ASTM Specification C 425. Reinforced concrete sewer pipe shall comply with ASTM Specification C 76, Class IV, unless a higher class is shown on the plans. Joints shall comply with the requirements of AWWA Specification C 302, using rubber "0-ring" gaskets. (o) Drain tile shall comply with ASTM Standard Specification C 4. (p) Culvert and surface drainage nine shall be reinforced concrete pipe and shall comply with ASTM Standard Specification C 76, Class III for reinforced concrete sewer pipe unless a higher class is shown on the plans. Joints shall be rubber "0-ring" gasket joints complying with AWWA Specification C 302. (q) Alternate types of pipe, fittings, and joints, when accepted or re- quired, shall be as specified in the Special Conditions. (r) Pipe supports and hangers shall be provided for all exposed pipe as shown on the plans or designated by the Engineer. Sufficient supports or hangers of the proper type and size, spaced not more than 12-feet apart along any line of the pipe, shall be furnished and installed to provide a rigid installation true to line and grade. Supports and hangers shall be of the size and type shown on the plans and shall be as manufactured by the Grinnell Co., `BPS Industries, or equal. ) Exposed outside piping shall be insulated to preve---t freezing where specifically shown on the plans. Insulating materials shall one-inch thick Armafle:t 22 sheet flexible foam plastic with closed cellular s_ructure as man,,:- factured by Armstrong Industry Products Division, Armstrong Cora; Co., or approved equal. Sheets shall be fastened to pipe with adhesive and galvanized steel bands. After installation, the insulation shall be coated with Armstrong Armaflex Finish (vinyl lacquer coating), or equal. 4.04 :oints and Joint Materials a) Flanged joints on ductile iron pipe shall be joined with nuts and bolts conforming to the chemical and mechanical requirements of ASTM Specifi- cation A 307, Grade B, 60,000 PSI tensile strength. Bolts and nuts shall be hexagonal. Bolts and nuts shall be threaded in accordance wit:: American National Standard 51... unified Inch Screw Threads (UN and UNR Thread Form), Class 2A ,:rand Mass 2B internal. Gaskets _or flanged joins water and sewazz? s s::ai_ 'oe full face of first qualred rubber, 1/8--nc'-. hick. Flexible tvne couplings on ductile iron pipe shall :)e mechanical join-_ sleeves, long pattern, which comply with the requirements of ANSI/AWWA Specifica- tion C110/A21.10; Dresser Coupling, Style 38, as manufactured by Dresser Indus- tries, Bradford, Pa.; or approved equal. Couplings shall be of the proper diame- ter to fit the outside diameter of the pipes on which they are used. °1sh-on" points on ductile iron pipe shall be as specified in Para ra ': `aereinbefore (d) Mechanical joints on ductile iron fittings shall be as specified in Paragraph 4.03(c) hereinbefore. (e) Gaskets for ductile iron pipe with mechanical joints and flanged joints used for air lines shall be suitable for an operating temperature of at least 250°F. (f) Grooved and shouldered type couplings for ductile iron pipe shall be fabricated in two or more segments of malleable or ductile iron. Gaskets shall be of molded synthetic rubber. Bolts shall be oval neck track type. Grooved type coupling shall be used on ductile iron pipe 24-inches in size and smaller and shouldered type couplings shall be used on ductile iron pipe 30-inches in size and larger. Pipe grooves shall be the flexible radius type unless the rigid radius type is shown on the plans. Grooved type couplings shall be suitable for a working water pressure of 150 PSI, minimum. Shouldered type couplings shall be suitable for a working water pressure of 175 PSI, minimum. Grooved and shouldered type couplings shall conform to the requirements of ANSI/AWWA C606. (g) Sanitary sewer pipe joints shall be as specified in Paragraph 4.03(m) hereinbefore. (h) Sewer pine joints shall be as specified in Paragraph 4.03(n) herein- before. (i) Culvert and surface drainage pipe joints shall be as specified in Paragraph 4.03(p) hereinbefore. 4.05 Wall Pipe Seals (a) Wall pipe seals shall form carrier pipe to wall pipe closures and shall be Link-Seals as manufactured by the Thunderline Corporation, Wayne, Michigan, or equal. (b) Seals shall be modular mechanical type consisting of interlocking synthetic rubber links shaped to continuously fill the annular space between the carrier pipe and the wall pipe. Links shall be loosely assembled with bolts to form a continuous rubber belt around the pipe with a pressure plate under each bolt head and nut. After the seal assembly is positioned in the wall pipe, tightening of the bolts shall cause the rubber sealing elements to expand and provide a water-tight seal between the carrier pipe and the wall pipe. (c) Pressure plates shall be made of Delrin plastic, infection molded for high physical properties, dielectric strength, and non-cold creep characteris- tics. The bolts, nuts, and metal parts shall be made of low carbon steel, zinc phosphate coated, to resist normal corrosion. The sealing element shall be made of EPDM synthetic rubber. (d) Wall pipe seals shall be installed in accordance with the manufac- turer's recommendations. 4.06 Rubber Expansion Joints (a) Rubber expansion joints shall be of the spool type, concentric or eccentric as shown on the plans, and shall be constructed of high grade neoprene compound combined with plies of sturdy cotton duck. Bodies shall be reinforced with steel rings. Arches shall be filled with soft rubber. Flanges shall be drilled in accordance with ANSI/AWWA Specification C115/21.15, and shall be provided with galvanized steel retaining rings. --ontrol units designed for the working pressure of the Joints shall limit :he horizontal mo•;ement of the expan- sion joints. (b) Rubber expansion joints shall be suitable for at least 125 PSI working pressure in 12-inch sizes and smaller and for at least 90 PSI working pressure in sizes 14-inch through 36-inch. They shall be as manufactured by Garlock Packing Co., Uniroyal Industrial Products, Murcer Rubber Co., General Rubber Corp., or equal. R 4.07 Gate Valves (a) Gate valves 3-inches in size and larger shall be the double disc type which conform to the requirements of ANSI/AWWA Specification C500 or the single disc or gate resilient seat type which conform with the requirements of ANSI/AWWA Specification C509, except as such specifications are modified herein. (b) Double disc type gate valves shall have parallel seats, cast iron or bronze discs or gates, bronze gate and seat rings, and shall be suitable for 200 PSI working water pressure in sizes 12-inches and smaller and 150 PSI working water pressure in sizes larger than 12-inches. (c) Single disc or gate resilient seat type gate valves shall have cast iron gates with vulcanized synthetic rubber coating or rubber seats mechanically retained on the gates and shall be suitable for 200 PSI working water pressure in all sizes. Valve interior and exterior surfaces shall be epoxy coated in accor- dance with the requirements of ANSI/AWWA Specification C550. (d) All gate valves shall be iron body, inside-screw type with non-rising stems. Stems shall be sealed with two 110" ring seals. All gate valves shall be as manufactured by American-Darling Valves, Mueller Co., M & H Valves and Fit- tings Co., U. S. Pipe and Foundry Co., or approved equal. (e) Gate valves shall be of the nominal diameters called for on the plans and, when opened, shall afford an unobstructed waterway of equal to or greater than the full nominal inside diameter. (f) In general, all gate valves 3-inches in diameter or larger installed on underground pipelines shall have mechanical joints and all gate valves 3-inches in diameter or larger installed inside buildings or structures shall have flanged ends, as shown on the plans. All valves 2-1/2-inches in diameter, or smaller, shall have screwed ends unless otherwise shown on the plans. Gate valves shall be either motor operated, hydraulically operated, or hand operated as shown on the plans. (g) Valves and operating mechanisms shall be of the proper size and dimen- sions to fit the pipe connections thereto and shall be installed in the position and within the space shown on the plans. All necessary guides and supports for late valve stems shall be furnished and installed where re wired. Suitable extension stems or operating keys of an approved design shall be furnished to 7roperly operate all valves installed with valve boxes. Two ..e,?s shall be fur- n'-shed. The cost of all guides, supports, extension stems, oerating keys and a;i other similar accessory items shall be included in the pr--':es of the valves, and no separate payment will be allowed therefor. (h) Mechanical joint ends shall be of the dimensions an-t design suited to receive the spigot ends of ductile iron pipe used in the work as designated else- where in these specifications. Where flanged ends are called for in the plans the flanges shall be dimensioned, faced and drilled to ANSI/':,WA Specification C115/A21.15. (i) Gate valve stems shall be designed to turn left, or counterclockwise, to open the valve and hand-operated valves shall have cas: thereon an arrow indicating the direction of opening. Hand-operated valves shall be equipped either with operating nuts, hand wheels, or manual floor star.-s, as shown on the plans. Gate valves larger than 12-inch installed undergrounc shall be the bev- e_ed gear type with enclosed gear boxes. Gate •:alves instal:-: in vaults, shall le Df the type shown on the plans. iI All- gate valves installed underground shal_ be ec_?:^ted with standar iron valve boxes unless otherwise shown on the plans. Nnere valves are sho,,n to be of smaller diameter than the connecting piping the two reducers required shall be included as fittings. (k) The Contractor shall submit to the Engineer complete catalog informa- tion, showing principal dimensions, weights, specifications and operating data f_;r .t:1 %:._ilves which he proposes to furnish. 4.08 Plug Valves (a) Plug valves shall be non-lubricated, eccentric plug type as manufac- tured by the DeZurik Corporation, Drum-Owen Valve Co. (Homestead Valves), or equal. (b) Plug valves shall have bodies of cast iron or semi-steel; plugs coated with Neoprene, EPT, or natural rubber; body seating surfaces of nickel' heavy duty bearings of stainless steel; and stem seals of the packing gland type or "U"-spring with rubber 11011-ring type. Port area shall be at least 80% of full pipe area in valve sizes 20-inches and smaller and at least 70% of full pipe area in valve sizes 24 and larger. (c) Plug valves shall be suitable for non-shock water working pressures of 175 PSI in sizes 12-inches and smaller and 150 PSI in sizes 14 to 36-inches. The valves shall provide drip-tight shutoff up to the full pressure rating or the valves in either direction. (d) End connections shall be flanged or mechanical joint as shown in the plans. In general, valves installed underground shall have mechanical joints and exposed valves shall be flanged. Flanged connections shall conform to the re- quirements of ANSI/AWWA Specification C115/A21.15. Mechanical joint connections shall conform to the requirements of ANSI/AWWA Specification C111/A21.11. (e) Operating means shall be by wrench or by worm-gear operator. Unless otherwise shown on the plans, valves 6-inches in size and smaller shall be lever operated and valves 8-inches in size and larger shall be worm-gear operated. Worm-gear operators shall be enclosed and of semi-steel construction. Exposed nuts, bolts, and washers on worm-gear operators shall be zinc plated. Valves nd operators for underground service shall be sealed to prevent moisture entrance to valve and operator parts. Valves installed underground shall be provided with extension stems and cast iron valve boxes. A sufficient number of standard levers and tee wrenches shall be furnished so that valves in each location are provided with at least one lever or tee wrench, as applicable. 4.09 Plastic Ball Valves (a) Plastic ball valves shall be the true union type constructed of poly- vinyl chloride. All parts of the valves shall be suitable for handling polymers. The valves shall be designed for an operating pressure of at ':east 110 PSI at a temperature of 1200F. Plastic ball valves shall be as manufactured by Celanese Piping System, Hayward Manufacturing Company, Inc., or equal. 4.10 Small Gate Valves (a) Gate valves smaller than 3-inches in size all bronze of the solid wedge disc, rising stem type and shall conform to the requirements of MSS SP-80, Class 200. (b) Small gate valves shall be installed with all pipe connections and fittings necessary to serve the purpose intended. 4.11 Butterflv Valves a) Butterfly valves shall be tight closing, stainiess steel to rubbe- _.pe seal achieved b%• rubber seats which are bonder _, or mechanical!- in the valve body, or rubber seats which are retained. or. the disc wit'n an 18-8 stainless steel clamp ring and stainless steel bolting. Valves shall be bubble-tight at rated pressures with flow in either direction, and shall be satisfactory for application involving rate-of-flow control, throttling service and/or frequent operation and for application involving valve operation after long periods of inactivity. Valve discs shall rotate 90 degrees from the full pan :)osition to the tight shut position. Butterfly valves s'.-.all meet the ful_ _rquirements of AWTA Specification C504, Class 150B. Bucte:-_i.• valves shall b- R , - as manufactured by the Henry Pratt Co., Mueller Co., American-Darling Valve, or equal. (b) Valve bodies shall be constructed of cast iron ASTM A126, and shall have integrally cast mechanical joint ends or flanged ends. Unless otherwise shown on the plans, butterfly valves installed underground shall have mechanical joint ends and exposed valves shall have flanged ends. Mechanical joints shall conform to the requirements of ANSI/AWWA Specification Cll/A21.11. Flanged joints shall conform to the requirements of ANSI/AWWA Specification C110/A21.15. Two trunnions for shaft bearings shall be integral with each valve body. Where the rubber seat is mounted on the vane, the valve body shall be fitted with a 360 degree stainless steel seat offset from the shaft, mechanically retained. (c) Valve discs shall be constructed either of alloy cast iron ASTM A436, Type 1 (NiResist) or of ductile iron ASTM A536 Grade 65-45-12. Where the rubber seat is mounted in the body, the mating edge of the disc shall be 18-8 stainless steel, Type 304 or Type 316. (d) Valve shafts shall be turned, ground, and polished. Shafts shall be constructed of 18-8 Type 304 stainless steel and shall be either a one piece unit extending full size through the valve disc and valve bearing, or may be the stub shaft design where solid ductile iron disc is used. (e) Valve seats shall be of natural rubber or synthetic rubber compound. Seats may be installed on the valve disc or valve body. Seats installed in valve bodies in valve sizes 20-inches and smaller may be vulcanized to the body or mechanically retained. Seats in valve bodies in valve sizes 24-inches and larger shall be mechanically retained. Seats installed on the valve disc shall be mechanically retained. Seats vulcanized to the valve body shall be simultaneous- ly molded in, vulcanized, and bonded to the valve body and seat bond shall with- stand a 75-pound pull under test procedure ASTM D429, Method B. Valve seats which are mechanically retained shall be field adjustable and replaceable without dismounting the valve disc or shaft and without removing the valve from the line. Retaining segments and adjusting devices shall be of corrosion resistant materi- als and shall be capable of a 1/8-inch adjustment. (f) Valve bearings shall be of the sleeve type which are corrosion resis- tant and self lubricating. Bearings load shall not exceed 1/5 that of the com- pressive strength of the bearin5 or shaft material and shall not exceed 2,500 PSI. (g) Valve interior surfaces, except seating surfaces shall be evenl•: coated with a suitable primer to inhibit rust or a black asphalt varnish. (h) Hydrostatic and leakage tests shall be conducted on butterfly valves in accordance with ANNSI/AWWA Specification C504, Section 12. (i) Valve operators shall be manual, hydraulic cylinder, or electric type as shown on the plans and as specified herein. Extension stems and bonnets and support brackets shall be provided where shown on the plans. (j) The valve manufacturer shall provide to the Engineer an "Affidavit of Compliance" in accordance with Section 17 of A.`iSI/AWWA Specification C504 and certified copies of "Proof-of-Design Tests" in accordance with Section 12.4 of AWWA Specification C504. 4,12 Manual Operators for Butterflv Valves a Manual operators for tterfi salves shall be to _ enclosed worm- gear or -ra eii^.? r.ut morn-gear and ,,raveling nut ; a o::?-rators sha.._ conform --o the requirements of ANSI/AW, A Specification C504. Manual operator, shall be designed to hold the valve in any intermediate position without creeping or fluttering. Valves shall close in a clockwise rotation of the handwheel. Units for underground service shall be fully gasketed, grease packed, watertight, and shall be provided with extension stem and operating nut, cast iron valve box, in?l tee wrench operator. 4.13 Ball Valves (a) Ball valves shall consist of a body assembly, a rotating closing element assembly, and a manual operator. With the valves in the full open posi- tion, the opening through the valve shall be equal to the nominal diameter of the connecting pipeline. Valves shall be of the double seat type permitting the bottle-tight shut-off of flow from either direction. Ball valves shall be suit- able for 150 PSI or 250 PSI working pressure, as shown on the plans. Where not specifically shown on the plans, ball valves shall be designed for a working pressure of not less than 150 PSI. (b) Each body assembly shall be cast iron conforming to ASTM Specification A126, Class B, and shall have flanges drilled in accordance with ANSI/AWWA Speci- fication C115/A21.15 for 150 PSI or 250 PSI valves. Body seating surfaces shall be stainless steel machined to a fine finish to provide an accurate seating surface for the rotor seat ring. Shaft bearings shall be an integral part of the body assembly and shall be sintered bronze impregnated with silicone for perma- nent lubrication. Maximum bearings pressure under a 150 or 250 PSI differential shall not exceed 200 PSI. The valve shaft seal shall be a cartridge type utili- zing "0-rings" to provide the seal. A thrust bearing assembly shall be provided at the bottom of the body assembly. Thrust bearing shall be adjustable. (c) Each rotating element assembly shall consist of the rotor, shafts, and rubber seat rings with retainers. The rotor shall be spherical of one piece construction. It shall be cast iron ASTM A48-48 Class 40. Water flow shall be through a straight passage equal in diameter to nominal size. The rubber seat rings shall be Hycar rubber and shall be retained by a removable and adjustable stainless steel retaining ring attached to the rotor casting with stainless steel cap screws. The valve shafts shall be turned, ground and polished 18-8, Type 304 stainless steel. (d) Operators shall be of the manual spur-gear or traveling nut type, fully enclosed, and shall comply with ANSI/AWWA Specification C507. Manual operators shall be designed to hold the valve in any intermediate position be- tween fully open and fully closed without creeping or fluttering. The handwheel shall require a pull of not greater than 80 pounds to open or close the valve. (e) Ball valves shall be factory tested in an open position at a pressure of 300 PSI for a period of not less than 30 minutes without leakage and in a closed position at a pressure of 225 PSI for a period of not less than 20 minutes without leakage. Valves shall also be cycled a sufficient number of times to demonstrate proper operation of all parts. Evidence of such successful tests shall be furnished the Engineer for each valve. (f) Ball valves and accessories shall comply with AWWA Specification C507 and shall be as manufactured by the Henry Pratt Company or equal. 4.14 Ball Valves for Check and Stop Service (a) Ball valves for check and stop service shall consist of a ball valve with a cylinder operator together with all necessary appurtenances. The ball valve shall comply with Paragraph 4.13 (a, b, c, e, and f) of these specifica- tions. b) Each valve shall be operated by a hydraulic cylinder which complies with Paragraph 4.15 of these specifications. Each cylinder s:-.all be furnished with the necessar,ti accessories and controls required to automat:-ally: i1) slow1 open ball valve after the pump motor has started; (?) slowly close the ball valve and stop pump motor after valve has reached some predetermined partially closed position (adjustable between 75-95% of full closure); and provide independent adjustment at the valve proper of normal opening and closing rates. Opening and closing rates shall be adjustable over a range of 0 to 10 minutes. Cylinders shall be sized to operate valves against the total shut-off head of pump on which the:: are installed. c) :he connecting piping from the pilo` control. '_%es to operating, M cylinders, limit switches, pressure switches, and other appurtenances shall be supplied as part of the valves. All control appurtenances shall be mounted on the valve or operating cylinder. The operating mechanisms shall include a manual override handwheel to operate the valve manually in case of operator supply pres- sure failure. (d) Accessories for ball valves for check and stop service shall be as manufactured by the Henry Pratt Company or equal. 4.15 Hydraulic Cylinder Operators for Ball Valves (a) Hydraulic cylinder operators for ball valves shall be furnished and installed, complete with all associated controls, where shown on the plans or specified herein. Cylinders shall be of metallic or non-metallic construction. (b) In metallic cylinders, the cylinder body shall be constructed of hard drawn copper base alloy; the piston of chrome plated steel; head and cap, of steel; piston rod, of chrome plated stainless steel; and rod wipers, rod seals, and piston cups of teflon. In non-metallic cylinders, the cylinder body shall be constructed of glass fiber reinforced epoxy resin with low-friction additives emulsified throughout; piston of non-metallic material designed with enlarged bearing area; rod gland of acetal copolymer; head and cap of phenolic laminate; piston rod of ground and polished steel, hard chrome plated; tie rods of high tensile cold rolled steel; seals of Buna N molded rubber; external rod wipers of Buna N molded rubber and internal rod wipers of such material which will remove any water deposited material from the rod. Cylinders shall be provided with an internal cushioning chamber at both ends of the stroke to prevent slamming of the piston. (c) Hydraulic cylinders shall be capable of operating valves on which they are mounted under a supplied water pressure of 50 PSI, but shall be suitable for a maximum water pressure of 150 PSI or 250 PSI, as applicable. (d) Open ends of cylinder piping shall have 1/2-inch combination flow control and stop valves attached prior to field installation. These valves shall regulate valve operation timing and also isolate the valve for removal or mainte- nance. ?e) Water piping to hydraulic cylinder operators shall be 3/4-inch Type K copper tubing with soldered connections. Unions shall be provided in the piping at each operator. 4.16 Sluice Gates (a) Sluice gates shall be of the sizes and shapes shown on the plans. The gates shall be the product of a manufacturer regularly engaged in such work. Gates and accessories shall be as manufactured by the Rodney Hunt Company, Coldwell-Wilcox, Co., or equal. (b) Sluice gates shall comply with the requirements of VNSI/AWWA Specifi- cation. C501, except as such specifications are herein modified. (c) Gate frames, discs, and guides shall be of cast iron. Wedges and seat facings shall be of bronze. Stems and stem coupling shall be of bronze or stain- less steel. Stem guides shall be adjustable in two directions and shall be space' at intervals to adequately support the stem, such spacing not to exceed.. 0 `e t. Miscellaneous small metal parts, including bolts an nuts and anchor- bolts shall be of bronze or stainless steel. :anchor oc:ts shall be the hook,'-end type, (d) Where gates with flush-bottom seals are required by the plans, such gates shall be equipped with compressible resilient seals attached to the bottom of the disc or on a cast iron bracket at the bottom of the frame. These seals shall be held in place with cast iron, bronze, or stainless steel bars and bronze or stainless steel bolts, nuts, and hardware. eN Frames shall be the flat type designed for mountinz on concrete walls -.t;i _, "tor bolts the concrete. M All sluice gates shall be the rising stem type. (g) Sluice gates shall be designed for the seating and/or unseating heads shown on the plans. (h) Operators for sluice gates shall be manual, of the type shown on the plans. (i) Anchor bolts for sluice gates shall be cast in the concrete and shall be accurately positioned by the use of suitable templates and secured during the placement of concrete. Gates shall not be mounted until concrete has thoroughly hardened and until authorized by the Engineer. Gates shall be mounted on the anchor bolts in the correct position and then a 1-inch layer of grout placed be- tween the frame and concrete wall. Anchor bolts shall be tightened after grout has dried. Care shall be exercised during installation to prevent springing the frame. Sluice gates shall be completely assembled, with the disc wedged lightly into its seat while being installed. (J) The Engineer may perform field leakage tests on all sluice gates in accordance with the provisions of ANSI/AWWA Specification C501. Leakage through sluice gates shall not exceed that specified in AWWA Specification C501. 4.17 Hand Operated Floor Stands and Bench Stands (a) Hand operated floor stands and bench stands shall be furnished and installed for valve and gate operation at the locations shown on the plans. Ex- tension stems and stem guides shall be provided as required. Cast iron wall brackets shall be installed where shown on the plans. All floor stands and bench stands shall be of cast iron weatherproof construction. Pipe cover indicators with open and closed markings shall be provided on all rising stem type floor stands and bench stands. Lubrication fittings shall be provided. Height shall be approximately 36-inches from bottom to top of handwheel or centerline of crank shaft. Maximum required handwheel or crank effort shall not exceed 40 pounds. (b) Class I floor stands shall be handwheel-operated rising-stem type de- signed to turn counter-clockwise to open. Handwheels shall have a cast-on-arrow indicating the direction of opening. The head shall contain a bronze operating nut mounted in roller or ball bearings with mechanical seals. Class I floor stands shall be Type S - 2600 or OS-2600 (as sho,.-n on tine plans) as manufactured by Rodney Hunt Co., comparable floor stands as manufactured by Colwell-Wilcox Co., or equal. (c) Class II floor stands shall be crank-operated rising-stem type and shall contain a bronze operating nut mounted in roper or ball bearings with mechanical seals. Class II floor stands shall have an operating ratio of 2 to 1 and shall be Type 5-5002 or OS-5002 (as shown on the plans) as manufactured by Rodney Hunt Co., comparable floor stands as manufactured by Coldwell-Wilcox Co., or equal. (d) Class III floor stands shall be crank-operated rising-stem type and shall contain a bronze operating nut mounted in roller or ball bearings with mechanical seals. Class III floor stands shall have an operating ratio of 4 to 1 and shall be Type 5-5004 or OS-5004 (as shown on the plans) as manufactured by Rodney Hunt Co., comparable floor stands as manufactured by Coldwell-Wilcox Co., or equal. !e) Class IV floor stands shall be handwheel-operated non-rising stem type with totally enclosed worm-gears with locking ce-:ice s,i:able butterfly valve operation. Class _'1 floor stands sha_: uti:-ze ?.a i ma::ua operator as manufactured by Philadelphia Gear Works, comparable Dperator as manufactured by EIM, or equal. (f) Bench-stands shall be handwheel-operated rising-stem type designed to turn counter-clockwise to open. Handwheels shall have a cast-on-arrow indicating the direction of opening. The head shall contain a bronze operating nut mounted in roller or ball bearings with mechanical seals. 3ench stands shall be Type BS-2600 as manufactured b•- Rodney Hunt :_-o., emparab_a bench. Stands as manufac- tured Coldwell-Wilcox :,o., or equal. 4.18 Telescoping Valves (a) Telescoping valves shall be of the rack and pinion type of extra sturdy construction, designed for a vertical travel of three (3) feet. The valves shall consist of off-set operating stand assemblies, lifting stems, seam- less brass tubes, and tube guide collars with Neoprene gaskets. Operating assem- blies shall be made of cast iron off-set floor stands and steel racks engaging steel pinions mounted on shafts which are rotated by 12-inch diameter cast iron handwheels. Locking devices shall hold valves at any desired position. Stain- less steel strips calibrated in one-half (1/2) inch increments shall indicate valve position. Lifting stems shall connect racks to the sliding tubes. Sliding tubes shall be seamless brass tubing having a minimum thickness of 1/8-inch and diameter to slide inside six (6) inch ductile iron pipes. Telescoping valves shall be as manufactured by Envirex, Inc., or equal. 4.19 Slide Gates (a) Slide gates shall be of the embedded frame and guide type, the spigot frame type with anchor bolts attached, or the flat frame type with anchor bolts, as shown on the plans. (b) The sliding disc as well as guides shall be of structural grade alumi- num alloy. The disc shall have a minimum thickness of k-inch and shall be re- inforced with structural members as required by the operating head condition. Guides shall have disc openings of 3/8-inch. (c) Where handwheel operation is required, frames shall be of structural grade aluminum and stems and connectors shall be stainless steel. Operators shall be handwheel operated bench stands for rising stems. Bench stands shall conform to the requirements of Paragraph 4.16 (f) of these specifications. (d) Where shown on the plans, gate discs shall have a resilient seal mounted on the lower edge for flush-bottom closure. (e) Detailed shop drawings of slide gates shall be submitted for review by the Engineer prior to their fabrication. (f) Slide gates shall be as manufactured by the Rodney Hunt Machine Co., Washington Aluminum Co., Thompson Fabricating Co., or equal. 4.20 :iaphragm Valves (a) Diaphragm valves shall be of the Saunders patent type having bodies constructed of rigid Koroseal or rigid unplasticized polyvinyl chloride and diaphragms of resilient reinforced Neoprene or Teflon. Diaphragm valves shall be the angle pattern when specifically required by the plans. (b) Diaphragm valves shall have screwed or flanged connections as shown on the plans. Flanges shall be drilled to the requirements of ANSI/AWWA Specifi- cation C115/21.15. (c) Diaphragm valves shall be suitable for a minimum working water pres- sure of 125 PSI. d) Diaphragm valves shall be as manufactured by B. F. Goodrich Co.; Tube Turns Plastics, Inc.; Grinnel Co.; or equal. ?ressure Reducing Valves Three Inches (3") in Si_2e and 'arzer ?a) Pressure reducing valves 3" in size and larger shall be the single seated, diaphragm actuated, globe type with reducing pilot control system. (b) Valve bodies shall be of cast iron construction, main valve trim of bronze, pilot controls of bronze, and pilot control trim of stainless steel. Connections shall be flanged. The downstream pressure range shall be adjustable from 3,: co 110 PSI. -) Pressure reducing valves shall be C'_ass or Class 250, as shown. -he. ,'ans where not specifically shown on the plans, pressure reducing valve shall be Class 125. Flanges for Class 125 and Class 250 valves shall be drilled to the requirements of ANSI/AWWA Specification C110/21.15. (d) Pressure reducing valves shall be Model 90B in 3-inch size and Model 90 in sizes larger than 3-inches, as manufactured by the Cla-Val Co., or com- parable valves as manufactured by Golden-Anderson Valve Specialty Co., Ross Valve Mfg. Co., or equal. 4.22 Pressure Reducing Valves Two and One Half Inches (24") in Size & Smaller. (a) Pressure reducing valves 24" in size and smaller shall be Mueller Company H-9310 Series with galvanized iron strainer, or equal. Valve bodies shall be cast bronze or galvanized iron. Connections shall be screwed. Outlet pressures shall be adjustable between-25 and 84 PSI. 4.23 Check Valves (a) Check valves shall be the horizontal swing type, lever and spring operated. They shall have flanged ends for pipe 3-inches in diameter or larger and screw ends for pipe smaller than 3-inches unless otherwise shown on the plans. Flanges shall conform to the requirements of ANSI/AWWA Specification C115/A21.15. Check valves shall have cast iron bodies, neoprene faced discs, and bronze seat rings. Valve pins shall be of stainless steel and shall have "0-ring" seals. They shall be tested to 300 pounds per square inch hydrostatic pressure. (b) Check valves shall be of the nominal pipe diameter shown on the plans and shall be so designed that, when open, they will have a clear waterway section of not less than the full nominal inside diameter of the connecting pipe. Check valves shall be as manufactured by Mueller Co., M & H Valve & Fittings Co., American-Darling Valve, or equal. 4.24 Fire Hydrants (a) All fire hydrants shall conform to the requirements of ANSI/AWWA Specification C502 for dry barrel hydrants, except as such specifications are modified or amended herein, and shall be as manufactured by Mueller Co., M & H Valve & Fitting Go., American-Darling Valve, or approved equal. (b) Standard fire hydrants shall be furnished with two hose connections each 2-1/2-inches in diameter and one 4-1/2-inch diameter pumper connection. The valve openings shall be 5-1/4-inches and the hydrant headloss shall not exceed 3.0 PSI at 1,000 GPM of water flow through the pumper nozzle. (c) Where smaller hydrants are shown on the plans, these hydrants shall be furnished with 2-1/2-inch diameter hose connections. The valve openings shall be 4-1/4-inches and the hydrant headloss shall not exceed 2.0 PSI at 500 GPM of water flow through the hydrant with both nozzles in operation. (d) Hydrant flow testing and certification of flows and headlosses shall be performed/provided by an independent testing laboratory in accordance with the requirements of ANSI/AWWA Specification C502. (e) The length of each hydrant shall be suitable for operating under the conditions shown on the puns and shall be the vertical distance from the bottom of the connecting pipe to :he ground line of the hydrant when installed. (f) Hydrants shat: be designed for mechanical joint connections unless otherwise shown on the plans. Mechanical joints shall conform to the require- ments of ANSI/AWWA Specification C111/A21.11. Unless otherwise authorized by the Engineer, the nozzles and caps shall be chased to National Standard hose and steamer nozzle threads. Hydrants shall be equipped with safety or break-away flanges. Hydrant stem seals shall be the "0" ring type. (g) Hydrants shall be designed to open by turning the operating nut to the left, or counter-clockwise. An arrow and the word "OPEN" shall be cast in relief on the top of the hvdrant :o designate the direction of opening. Suitable oper- ating wrenches shall be furnished with hydrants. 4.25 Solenoid Valves (a) Solenoid valves shall be two-way, normally closed type for water having a safe working pressure of 300 PSI and a maximum operating pressure differential of 250 PSI. (b) Valve bodies shall be of forged brass and seals and discs shall be of Buna "N" or Teflon. Connections shall be screwed. (c) Solenoid enclosures shall be general purpose (NEMA 1). Solenoid shall be suitable for 120 volt, 60 Hz, single phase current operation. (d) Solenoid valves shall be as manufactured by Automatic Switch Co., or equal. 4.26 Backflow Preventers (a) Backflow preventers shall operate on the reduced pressure principal and shall consist of two independently acting toggle lever check valves, an automatic pressure differential relief valve, two gate valves, and four test cocks. (b) Backflow preventers shall be suitable for 150 PSI working water pres- sure. Connections shall be flanges which conform to the requirements of ANSI/AWWA specification C110. Main valve bodies and covers shall be of cast iron, galvanized. Main valve trim shall be of bronze, ASTM B 61. Differential relief valves shall be of bronze, ASTM B 61, with AISI 304 stainless steel trim. (c) Backflow preventers shall be Model RP, as manufactured by Cla-Val Co., comparable device as manufactured by Watts Regulator, Hersey Products, Inc., Neptune Water Meter Co., or equal. 4.27 Pressure Gauges (a) Pressure gauges for piping or pumps shall be of the Bourdon Tube type, having phosphor bronze tubes, steel cases, and steel rings. Cases and rings shall be finished in black enamel. Dials shall be 3?,-inches in diameter. Gauge: shall be Figure No. P500 L", as manufactured by C. S. Gauge Co., or equal. Each gauge shall be installed with k-inch brass pipe and gauge cock. 4.28 Street Washers or Flush Hydrants (a) Street washers or flush hydrants shall be of the freeze-proof type equipped with a drip valve to drain the riser, a nozzle for connecting a 3/4-inch diameter garden hose, a 3/4-inch inlet connection, and shall be Model 71600 as manufactured by the Josam Co., or equal. All street washers shall be set 2 feet into the ground. One wrench or operating key shall be furnished with each street washer. (b) Street washers shall be set so that their tops are flush with the ground surface or pavement at the point of installation. -wo cubic feet of gravel or crushed stone shall be placed around and below the drip opening. 4.'?? 7alve Boxes (a) Each underground gate valve and plug valves installed outside or buildings, or structures shall be provided with a valve box to house and protect the valve stem unless special concrete vaults are shown on the plans. Valve boxes shall be made of cast iron, of the adjustable sliding type, with a shaft diameter of 5:-inches. The base shall be round or oval. The box shall be pro- vide,i wi`h an extension section so that, when installed t^e cover will 7, sli!:-:zly above ground surface. r }.l V, 1 - h-__, o*-l 1 },o G; -__ OiIS ?? ..,?.,,,F ,,.r,,.-o .a ti.•• r`..?1 L., r.......?.-• Co., or comparable boxes as manufactured by the Mueller Co., John Bouchard & Sons, Co., or equal. (c) After the gate valves have been completely installed and tested but before they have been backfilled, the valve boxes shall be installed on a firm base at the proper elevation and then carefully backfilled and tamped so that after the backfilling has been completed the top surface will be not more than 4-inch above the ground surface. A concrete pad 2 feet by 2 feet by 6-inches thick shall be poured around all valve boxes in unpaved areas. Valve boxes set in paved area shall be erected with the top flush with the surface of the pave- ment. In its final position the box shall not touch the valve stem at any point. 4.30 Identification Tags (a) All unsafe water outlets shall be identified by a one (1) inch dia- meter brass or bronze tag secured to the outlet by a non-corrodible chain. Each tag shall be marked "Unsafe Water". 4.31 Alternate Type Valves (a) Alternate types of valves, gates, hydrants, and accessories when acceptable or required shall be as specified in the Special Conditions. 4.32 Construction- General (a) Pipe and accessories shall be handled in such a manner as will insure delivery to its final position on the work in an undamaged condition. Pipe coating and lining shall be carefully protected. The inside of each section shall be thoroughly cleaned just before it is placed in final position, and shall be kept clean and free of water during laying operations. No pipe shall be laid in water or when the trench or other conditions are unsuitable for such work. Water shall be kept out of the pipe trench until the pipe has been laid and the joint material has hardened. (b) All pipe shall be inspected just before it is placed in final position and rung with a light hammer to detect defects. Any pipe or accessories found to be defective, damaged or otherwise unsuitable for the purpose either before or after its installation shall be removed by the Contractor and replaced with acceptable pipe at Contractor's expense. (c) The cutting of pipe for closure pieces or for other purposes shall be done in a neat and workmanlike manner, without damage to the pipe, by the use of a wheel cutter or other approved type of mechanical cutter. (d) Unless otherwise shown on the plans or authorized by the Engineer, no ductile iron pipe shall be laid in trenches where the depth of cover will be less than 30-inches. (e) Temporary support, adequate protection and maintenance of all under- ground and surface utility structures, drains, sewers, and other obstructions encountered in the progress of the work shall be furnished by the Contractor at his own expense. Wherever existing utility structures or branch connections leading to main sewers or to main drains, or other conduits, ducts, pipes, or structures present obstructions to the grade and alignment of the pipe, the-, shall 'De permanently supported, removed, relocated, or reconstructed by the Contractor through cooperation with the Owner of the utilitv, structure, or obstruction involved, (f) All pipe shall be laid and maintained to the required lines and grades; with fittings and valves at the required locations; and with joints centered and spigots home; and with all valve stems plumb. When in final posi- tion the invert of the pipe shall be at the exact elevation and grade shown on the plans. No deviation shall be made from the required line or grade except with to consent of the Engineer. 4.33 Laying Pine (a) Each section of pipe shall be placed in the prepared trench with the full length of the barrel resting upon the pipe bed and with the bell over a bell hole excavated at the proper joint to accommodate the bell and permit preparation of the joints. Where angular deflections from a straight line or grade are made necessary by vertical or horizontal curves or offsets in ductile iron pipe, the deflection shall not exceed six (6) divided by the nominal diameter (in inches), per lineal foot for pipe less than 14-inches in diameter, nor four and five- tenths (4.5) divided by the nominal diameter (in inches) per lineal foot for pipe 14-inches or more in diameter. The deflection is to be measured between the center lines, extended, of any two connecting joints of pipe. Where deflections in excess of such limits are necessary, special bends shall be provided, or, if approved by the Engineer, shorter lengths shall be used in sufficient number to provide the angular deflection required. (b) Except where necessary to make connections with other lines, pipes shall be laid with the bells facing the direction of laying. For lines on an appreciable grade the joints shall be faced upgrade. (c) After each section of pipe has been lowered into the trench and before jointing operations are started all lumps, blisters and excess coating materials shall be removed from the surfaces to be jointed and the outside of the spigot end and the inside of the joint shall be wire-brushed, wiped clean and dry, and all oil and grease removed. The cleaning operations shall be repeated, if neces- sary, just prior to making the joint. (d) The fittings at all bends in underground pressure lines shall be securely anchored so as to prevent the fittings from being blown off when under pressure. Where pipe ends are dead-ended to permit future connections they shall be valved, plugged or capped and then braced with masonry. Connections between new and old lines and between different kinds and types of pipe shall be made with standard or special fittings to suit the actual conditions and shall be made in a neat and workmanlike manner acceptable to the Engineer. (e) Flanged ductile iron pipe shall be installed in the manner specified above for mechanical Joint pipe except that the faces of the flanges on two adjacent sections shall be carefully centered and the sections adjusted to proper line and grade before the flange bolts are tightened. Gaskets shall be placed in position without damage. Any gaskets damaged in the process shall be discarded. They shall be attached to the flange by rubber gum before the jo:nt is made up in a manner that will prevent displacement. After the pipes have been properly centered and adjusted to true line and grade they shall be firmly bolted togeth- er, care being taken to tighten all nuts around the flange to the same degree of pressure. Suitable flanged wall fittings or thimbles shall be used where pipes pass through walls of structures. (f) Mechanical joints and "push-on" joints for ductile iron pipe shall be installed in strict accordance with the recommendations of the joint manufac- turer. (g) Before sewer pipe or surface drainage pipe is placed in position in the trench the bottom and sides of the trench shall be carefully prepared and the necessary bracing and sheeting installed as provided in Item I of these specifi- cations. A mason's line shall then be tightly stretched above ground level. oara-e- to _::e directlv above the axis o- the pipe to be installed, this line tc .,e suppor_ed at intervals not exceeding 50-feet. Tne exact Line and grade for each section of pipe, shall be determined by measuring down from this line to the invert of the pipe in place. Each pipe shall be accurately placed to the exact line and grade called for on the plans. The Contractor shall furnish all labor and materials necessary for erecting batter boards. (h) Bell holes shall be of sufficient size to allow ample room for pro- peri•: makins the ripe ;pints. Bell holes shad be cut net more than ten joints the i? l aloa lavir.:,. The bottom of _rench ;,etwee:: De`_ roles shall be .ar = _- __?ded so '..iat the pipe oar- e'_ ._-- ra;' on ., soli" uadation for its entire length. Each joint shall be laid so that it will form a close concentric joint with adjoining pipe and so as to avoid sudden offsets or inequalities in the flow line. (i) After the joints have been completed they shall be inspected and accepted by the Engineer before they are covered up. Any leaks or defects dis- covered at any time after completion of the work shall be repaired immediately. Any pipe which has been disturbed after the joint was poured shall be taken up, the joint cleaned and remade and the pipe relaid at Contractor's expense. All pipe in place shall be carefully protected from damage until the backfilling operations have been completed. (j) Water shall not be allowed to run or stand in the trench while pipe laying is in progress or before the joints are made or before the trench has been backfilled. The Contractor shall not open up at any time more trench than his available pumping facilities are able to dewater. (k) Backfilling the trenches shall be started immediately after the pipe is in place and the joints completed and inspected and accepted by the Engineer. Backfilling shall be performed in accordance with the provisions of Item I of these specifications. 4.34 Setting Fire Hydrants (a) All fire hydrants shall be set plumb and shall conform to the estab- lished grade. Nozzles shall be at least 12-inches above the ground. (b) Wherever hydrants are set in impervious soil, a drainage pit 2-feet in diameter and 2-feet deep shall be excavated below each hydrant and filled com- pactly with coarse gravel or crushed stone under and around the bowl of the hydrant and to a level 6-inches above the waste opening. No hydrant drainage pit shall be connected to a sewer. (c) The bowl of each hydrant shall be well braced against unexcavated earth at the end of the trench with concrete backing, or it shall be tied to the pipe by other means shown on the plans or authorized by the Engineer. 4,35 Manholes (a) Manholes shall be constructed to the sizes, shapes and dimensions and at the locations shown on the plans. Unless otherwise shown o the plans, man- holes shall be four (4) feet in diameter. The height or depth of each manhole will vary with the location, but it shall be such as will place the top at the finished grade of the pavement or ground surface or to the elevations shown on the plans and the invert at the elevation design on the plans. (b) Where the difference in the invert elevation of two or more sewers 18-inches in diameter or smaller intersecting in one manhole is 2-feet or more, a drop manhole shall be constructed in the manner shown on the plans. They shall be similar in construction to the standard manhole except that a drop connection of pipe and fittings of the proper size and material shall be constructed outside the manhole and supported by Class B concrete as indicated on the plans. (c) Manholes shall be precast reinforced concrete pipe manhole sections with tongue and groove joints. Manholes shall conform to the requirements of ASTM Specification C478, except as modified herein. Concrete used in their manufacture shall have an absorption rate not to exceed spercent. The minimum wall thickness of the manhole riser sections shall be. ve (5) inches for four (4) foot diameter manholes, six (6) inches for five (5) ?ooc diameter man- holes, and seven (7) inches for six (6) foot diameter manholes. Cone sections shall have a minimum wall thickness of eight (8) inches at their top. Base riser sections shall be made with bottoms cast monolithically. Bottoms cast into already made pipe sections are not acceptable. The minimum thickness of the bottom shall be six (6) inches for manholes four 4), five ;5 . and six (6) fees in diameter. Suitable openings for inlet and outlet sewer 7-; e shall be cas` into the base sections and into riser sections for dro: zonnections. These openings shall be circular, accurately made, and located as required for each manhole. Base riser sections shall be set on compacted pipe embedment materials six (6) inches in thickness. Pipe embedment materials, so used, shall be Class IV or of the same type being used for pipe embedment. (d) The length of tongue and groove joints on manhole sections shall be not less than the wall thickness of the sections. The nominal clearance between tongue and groove pieces shall be 1/16-inch. The manhole sections shall be joined with "0-ring" rubber gaskets conforming to the requirements of ASTM Speci- fication C443. Rubber gaskets shall be installed in accordance with the recom- mendations of their manufacturer with the use of a suitable lubricant. A suitable rectangular recess shall be cast into the tongue of each manhole section to contain the rubber gasket such that when the joint is made, the rubber will be confined on all four sides. In addition, a flexible plastic joint sealant shall be applied to manhole section joints of sanitary sewer manholes but is not re- quired on section joints of surface drainage manholes. The sealant shall be a factory extruded formulation of 100 percent solids with top-quality partially vulcanized butyl rubber which provides shape retention in combination with adhesion and cohesion. The sealant shall conform to the requirements Federal Specification SS-S-210A. It shall be applied to clean, dry surfaces only. (e) Flexible manhole sleeves shall be installed on all sanitary sewer pipe entering and leaving manholes. Flexible manhole sleeves are not required on surface drainage pipe entering and leaving manholes. Manhole sleeves shall be of high quality synthetic rubber which complies with the requirements of ASTM Speci- fications C923 and C443. Manhole openings shall be accurately core drilled. Sleeves shall be secured to the manholes by Series 302, 304, or 305 stainless steel bands with self-locking toggles to make watertight unions. Sleeves shall be secured to the sewer pipes to make watertight unions by Series 302, 304, or 305 stainless steel clamps, draw bolts, and nuts. Flexible manhole sleeves shall be Kor-N-Seal as manufactured by N.P.C. Inc.; comparable manhole sleeves as manufactured by Press Seal Gasket Corp.; or equal. (f) Manhole inverts shall be constructed of cement grout and shall have the same cross-section as the invert of the sewers which th?v connect. The manhole invert shall be carefully formed to the required size and grade by gradual and even changes in sections. Changes in direction of flow through the sewer shall be made to a true curve with as '_ar,se a radius as the size of the manhole will permit. Pipe sewers larger than !-;-inches in s:zz- shall be grouted into manhole walls using a non-shrinking grout. (g) After the manhole has been set in its final positi:n, the cast iron frame for the cover shall be carefully set at the required elevation and properly bonded to the masonry with cement grout. Where manholes are constructed in paved areas, the top surface of the frame and cover shall be tilted so as to conform to the exact slope, crown and grade of the existing pavement adjacent thereto. (h) Manhole frames and covers shall be made of cast iror. conforming to the minimum requirements of Federal Specification WI;-1-652 or to ASI`i Specification A 48. All castings shall be made accurately to the required dimensions and shall be sound, smooth, clean and free from blisters and other defects. Defective castings which have been plugged or otherwise treated shall be rejected. Frames and covers shall be as detailed on the plans. The contact surfaces between the co:ar and its corresponding suDPorting rinz in the frame be machined so -'n?- -.e cover wi -: rest on the -ng for the per._,neter --ne _'ontact sur- fa-es. Castings shall be thorough'-y cleaned and, before rust:r:, begins, shall be painted with a bituminous coatir.S so as to present a smootc finish tough and tenacious when cold, but not tacky nor with anv tendency to scale. There shall be no holes or perforations in the covers. .i) Manhole steps shall be constructed of steel covered with rubber or plastic and shall consist of a 112-inch diameter stee'_ reinforcing rod covered ?v a c,,_--osion resistant rubber or copolvmer polvprop: e::a as The minimu:r read w.:'.ch shall ^e inches. -":ie steo.; s:n aincor prat, -radio;: c leats an o g.:i.:e lugs. "Abber or alas? c covered s=ee: scrips s-,-'- as ;nanufacturec'. by Delta Pipe Products Co., M. A. Industries, Inc., or equal. 6, manhole steps shall comply with the requirements of OSHA. (j) Manholes for sewers 48-inches in diameter and larger shall be con- structed on reinforced concrete bases factory cast on the barrel of a joint of pipe. The design of these manhole bases shall be reviewed by the Engineer. Manhole barrels to be constructed on precast bases shall be precast concrete. Where factory cast reinforced concrete bases are used on sewers at points of alignment change, factory made bends shall be installed downstream from the manhole bases. (k) Drawings and descriptive data on manholes, rubber gaskets, joint sealant, flexible manhole sleeves, frames and covers, and manhole steps shall be submitted to the Engineer for review prior to their manufacture. 4.36 Drainage Inlets (a) Drainage inlets shall be constructed of brick masonry or Class A concrete to the size, shape, and dimensions shown on the plans. (b) Brick shall be medium hard or better quality brick conforming to the requirements of ASTM Specification C32, Grade NA. (c) Mortar shall be composed of one part (by volume) of Portland cement and two parts sand. Mortar shall be prepared only in the quantities needed for immediate use. Mortar which has been mixed for more than 30 minutes or which has set or has been retempered shall not be used in the work. (d) Castings shall be of cast iron of the shape and to the dimensions shown on the plans. Cast iron shall conform to the requirements of ASTM Specifi- cation A 48 for "Gray Iron Castings". All castings shall be made accurately to the required dimensions and shall be sound, smooth, clean, and free from blisters or other defects. Defective castings which have been plugged or otherwise treat- ed shall be rejected. Castings shall be thoroughly cleaned and, before rusting begins shall be painted with a bituminous coating so as to present a smooth finish, tough and tenacious when cold but not tacky nor with any tendency to scale. 4.37 Installation of Small Pine and Fittines ia) Metal pipe and fittings shall be erected with screwed joints with clean cut tapered threads. Joints shall be made with white lead. All pipe work shall be done in accordance with best standard practice by competent and experi- enced workmen and shall be in strict conformity with all of the applicable provi- sions and requirements of state and local ordinances. 4.38 Settine Valves Valve Boxes and Fittings (a) Gate valves and fittings shall be set and jointed to pipe in the manner heretofore specified for cleaning, laying and jointing pipe. (b) Cast-iron valve boxes shall be installed on all outside valves and shall be firmly supported, and maintained, centered, and plumbed over the wrench nut of the gate valve, with box cover flush with the surface of the ground or finished pavement, or at such other level as may be directed. x.39 nchoraze of Bends Tees and Plums (a) Reaction or thrust backing of Class "B" Concrete shall be applied on all pressure pipe lines 4-inches in diameter or larger at all tees, plugs, caps and at bends. 4.40 Hydrostatic Testing of Pressure Pipe (a) After pressure pipe has been laid or erected and partially backfilled (as specified herein) all newly laid pipe or any valved section thereof shall be subjected to a hydrostatic pressure approximately 50% above normal operating pressure, but not less than 100 PSI and not greater than the pressure rating of the pipe. The duration of each pressure test shall be at least two hours for uncovered pipe and six hours for covered pipe. (b) Each valved section of pipe shall be slowly filled with clean water and the specified test pressure, measured at the point of lowest elevation, shall be applied by means of a pump connected to the pipe in a satisfactory manner. The pump, pipe connection, gates, meters and other apparatus required for the tests shall be furnished and installed by the Contractor. (c) Before applying the specified test pressure, all air shall be expelled from the pipe. To accomplish this, taps shall be made, if necessary, at points of highest elevation, and afterward tightly plugged. (d) All exposed pipes, fittings, valves, and joints shall be carefully examined during the open trench test. All leakage in joints shall be completely stopped. Any cracked or defective pipes, fittings, or valves discovered in con- sequence of this pressure test, shall be removed and replaced by the Contractor with sound material in the manner hereinbefore provided and the test shall be repeated until satisfactory to the Engineer. (e) Should any test of combined sections of pipe laid disclose leakage the Contractor shall at his own expense locate and repair the defective joints until the leakage has been completely stopped. 4.41 Chlorination (a) Before being placed in service completed potable water pipe lines shall be chlorinated by the Contractor, under the direction of the Engineer, by the method herein specified. (b) Prior to chlorination, all dirt and foreign matter shall be removed by a thorough flushing through the hydrants, or by other approved means. Each valved section of newly laid pipe shall be flushed independently. This shall be done after the pressure test and may be done either before or after the trench shall have been backfilled. (c) A solution of hypochlorite (HTH) shall be fed into the section of water pipes being disinfected to insure a chlorine dosage of at least 50 parts per million throughout the pipes. (d) Treated water shall be retained in the pipe long enough to destroy all non-spore-forming bacteria. This period shall be at least 24 hours and prefer- ably longer as may be directed. After the chlorine treated water has been re- tained for the required time, the chlorine residual at pipe extremities and at other representative points shall be at least 25 parts per million. (e) In the process of chlorinating newly laid pipe, all valves or other appurtenances shall be operated while the pipe line is filled with the chlori- nating agent. (f) Following chlorination, all treated water shall be thoroughly flushed from the pipe line at its extremities until ^,e replacement water throughout its length shall?, upon test, both chemically: an? bacteriologicall•:, be proven to be safe f.r human use. ,rater samples for bacteriological examination shall be. submitted to the State Health Department Laboratory by the Contractor from water lines after chlorination. Should the initial treatment in the opinion of the Engineer prove ineffective, the chlorination procedure shall be repeated until confirmed tests show that :rater sampled from the newly laid pipe conforms to the above requirements. 4.42 Painting (a) After all iron piping work has been tested and all necessary repairs or adjustments have been completed, all permanently exposed pipe, fittings, valves, gates, accessories, and other metal surfaces shall be painted in strict conformity with all applicable requirements of Item VIII of these specifications. 4.43 Payment (a) No separate payment will be made for Wastewater Treatment Plant/Pumping Station Piping performed under these specifications, but this work shall be included in the lump sum payment for the Wastewater Treatment Plant/Pumping Station, as applicable. STD-WWTP.P ITEM V SIDEWALKS. PAVEMENT AND SURFACING 5.01 Scope (a) The work covered by this item shall consist of the construction in place of new access roads, driveways, concrete sidewalks, curb and gutter, pavement, and surfacing, or the replacement of concrete sidewalks, driveways, curbs and gutters, and surfacing of whatever nature which have been removed to permit the construction of pipelines or other work, all at the locations and to the lines and grades shown on the plans or designated by the Engineer. All replacements shall be of the same type construction as was removed. (b) Where sidewalks, driveways, curbs and gutters, or surfacing of whatever nature have been removed by the Contractor beyond the limits called for in the plans and specifications or as set by the Engineer, or have been damaged through negligence or carelessness of the Contractor's forces, they shall be replaced in accordance with these specifications at the Contractor's expense. (c) Where the surface of graveled or similarly surfaced driveways or streets is removed by the Contractor, either within or without the construction limits or have been damaged by the Contractor's forces they shall be replaced with the same materials that were removed or damaged at the Contractor's expense as an incidental part of the work. (d) On unit price contracts where sidewalks, curb and gutter, paved drive- ways or paved streets are removed within the construction limits as specified and with the consent of the Engineer they shall be replaced in accordance with the applicable requirements of these items and shall be paid for in the manner spec- ified in this item. (e) On lump sum contracts no separate payment will be made for the con- struction or replacing of sidewalks, pavement, and surfacing, nor for other work performed under this item. 5.02 Materials (a) Concrete work in the construction or replacement of sidewalks, drive- ways, curbs and gutters, and road pavement shall be constructed of plain concrete, meeting all of the applicable requirements of item II of these specifications. Concrete shall be Class 3. Concrete forms shall be of wood or metal, shall be straight and free from warp, and shall be of sufficient stren-th, when in place, to hold the concrete true to line and grade without springing or distortion, and shall conform to the applicable requirements of Item II. The quality and suitability of steel forms shall be accepted by the Engineer prior to their use in the work. Bituminous preformed joints 1/2-inch thick shall be furnished and installed at points herein specified or shown on the plans. Preformed expansion joints shall conform to the requirements of AASHO Specification Designation M33 and M153. (b) Surfacing of graveled or similarly unpaved driveways or roads for construction or replacement shall consist of hard, durable pit run gravel, crushed stone or chert of suitable gradation for road surfacing, and shall be accepted by the Engineer prior to being delivered to the site of the work. c) Materials for the construction or replacement of bi7uminous pavements; shall '::e furnished in accordance with the current applicable standard specifica- tions c` the State HiQhwa: Department of the state in which --h, .ors located fog- each ,_ or kind of pavement to be constructed or replaced. 5.03 Concrete Construction (a) Excavated areas beneath concrete sidewalks, driveways, streets, curbs and ,utters and roads shall be backfilled where necessarv and -_aoroughly compacte(.'. to the _equired -rade, :;lope and densit.v . the manner describe :.n items I and II_ )f -.•.ese specifications .:,.e final :;ubgr.i::a surface shall be :.,::pac ed to an eve. density and firmness and shall be smooth and true to line and grade prior to placing concrete. (b) New concrete sidewalks and curb and gutter shall be Class B concrete, unreinforced, as specified in Item II of these specifications; constructed to the width, thickness and length shown on the plans. New sidewalks shall be 4-feet in width and 4-inches in thickness unless otherwise shown on the plans. (c) Concrete sidewalks, driveways, curb and gutter being replaced shall be Class B concrete, unreinforced, as specified in Item II of these specifications 6-inches thick and of the same width, length, shape and grade as the section re- moved. Concrete pavement in streets and roads shall be replaced to the original size, shape and grade with Class B concrete pavement 8-inches thick. (d) Concrete side forms shall be carefully set with their top true to line and grade of the finished work and shall be rigidly held in place by stakes or braces. Forms shall be cleaned and oiled before they are set in place. Subgrade and forms shall be approved by the Engineer just prior to concrete placement, after which the subgrade shall be dampened, if necessary, and the freshly-mixed concrete placed in the amount required to fill the area within the forms to the proper finished grade in one course. The concrete shall be thoroughly tamped or vibrated, struck off with an approved straightedge and floated with a wooden float true to the required grade and slope. The finished surface shall have a surface tolerance of not more than k-inch in 10-feet. Curb and gutter shall be constructed in ten (10) foot sections. Preformed bituminous expansion joints shall be placed in curb and gutter and sidewalk construction at fifty (50) foot intervals. Sidewalks shall be deep marked at four (4) foot intervals. (e) All completed concrete surfaces shall be immediately covered with wet burlap or other approved material and kept continuously damp for a period of not less than 5 days, and shall be protected from damage during the curing process and thereafter until finally accepted. Any section that is damaged during construction or before final acceptance shall be replaced in a satisfactory manner by the Contractor at his own expense. No pedestrians or vehicular traffic shall be allowed on concrete walks or paving during the curing period and in no case less than 5 days after placement. 5.04 Hiy-hwa• Crossines ( a) ,;here it is necessar_, to cross, cut, destroy or rep:--e sections across or along highwavs owned or maintained by the State Higtl a:: Department the Contractor shall make all preliminary arrangements with the State Highway Depart- ment and shall obtain all necessary permits and licenses and shall provide all bonds or deposits, The Contractor shall comply with all rules and regulations of the State Highway Department applicable to the work, and shall furnish materials and perform all work in accordance with any specifications which may be furnished to the Contractor by the State Highway Department. 5.05 Street Crossings (a) "w"here pipe trenches are cut across or along existi:::- street or alley pavement or surfacing, thev shall be backfilled in the manner specified in Item I of these specifications and traffic restored as quick-1,; as oo-sible by the con- struction of a temporarv surface of crushed stone or material, a: app_icao.e _-.e _ontractor shai ma n tai^ 131:csU'r-_ - ac,?s until th<• permar.en:. s,rfasir.` has been placed. eplacemer.t `.)numinous : a :emet:t shall have a thickness equal to that removed but shall in no case be less than 3-inches in thickness. Replacement concrete pavement shall be of the thickness and type shown in Paragraph 5.03(c) of these specifications. ?b) 'mere pipelines cut across or along existing unimtroved or graveled streets or '.'.evs, then shall be back-filled in _i manner spe.c_ Led in Item I of -hesa ;oec:__ .it'_ons an(! ..-raffic restored as a?: pos_ _ placing a' _eas'. n es o rue. - <.?.. .. rus ed - _ s-, 0-"-? 1 c;.- _ -- _., in: The Con- tractor shall maintain the surfacing in good condition until acceptance of the work. (c) All excess materials and debris shall be removed from the site of the work and the areas left in a neat workmanlike condition. 5.06 New Unpaved Access Roads and Driveways (a) New unpaved access roads and driveways shall be constructed with a surfacing of pit-run gravel, crushed stone, or chert placed to a thickness of 4- inches unless otherwise shown on the plans. It shall be spread, leveled, compacted, and maintained in good condition until final acceptance of the work. 5.07 New Paved Access Roads and Driveways (a) Base course and pavement of new access roads and driveways shall be as specified in the Special Conditions, if required in the project. 5.08 Resurfacing Existing Bituminous Paved Access'Roads and Driveways (a) Resurfacing of existing bituminous paved access roads and driveways shall be as specified in the Special Conditions, if required in the project. 5.09 Pavement Line Striving (a) Pavement line striping shall be as specified in the Special Conditions, if required in the project. 5.10 Removing and Resetting Existing Work (a) When so specified, sections of existing curb, gutter or sidewalks or combination curb and gutter may be removed in lengths of 4-feet or more and reset provided they are not injured or damaged in the process. Any section found unsuitable for resetting after removal shall be removed from the work. Any sectioT, damaged shall be replaced with a new section at the Contractor's expense, ) After removal, all sidewalks, curb and gutter found b•r the Engineer to be suitable for resetting shall be carefully stored until t:he pipeline or other work has been completed. It shall then be cleaned and read•.:sted upon a firm, compacted subgrade prepared as specified herein for new work and set to the proper line and grade, after which the joints shall be filled with an approved bituminous filler. All joints and tops shall be redressed when necessary to provide a smooth even surface with the old work. After the joints have set, the replaced sections shall be backfilled, tamped and given a finished, even surface in the manner specified for new work. 5.11 Determination of Pav Quantities (a) On unit price contracts the quantities of sidewalks, pavement and surfacing for new construction or replacement for which pavment will be allowe(: shall be expressed in square yards of area, to the nearest '_/'__?-square yard. For n.ew construction, the quantities shall be computed from the _11owable width a: shown )n -.he plans and the actual horitonta- iengt: mea u:-_ iT; place. replacement, the quantities shall be computed from the trenc. w dth shown on ttit plans and the actual horizontal length measured in place. (b) On unit price contracts the quantities of curb and gutter for new construction and replacement shall be expressed in lineal feet, to the nearest 1/10-foot. For new construction, the quantities shall be the horizontal length as measuredl in place. For replacement, the quantities shall be th.e horizontal lengtl. which ::all be equal to the trench width shown on t1-.e plans. `;o speci_ic pavment wi1_ be .-i'_:owed for the rr. '_ace^e::t of surfacing 0 graveled or similarly surfaced streets and driveways or for paved surfaces damaged or removed beyond the specified limits of the work. 5.12 Payment (a) On lump sum contracts no separate payment will be made for the con- struction or replacing of sidewalks, pavement, and surfacing, nor for other work performed under this item. (b) On unit price contracts payment for sidewalks, pavement, and surfacing constructed or replaced under these specifications shall be made for the quantities determined in the manner specified above at the unit contract prices per square yard or per lineal foot, as applicable, for the items listed under Item V of the contract pay items. This amount, so paid, shall cover the cost of furnishing all materials, labor, tools, plant and other expense in connection with or incidental to the construction or replacement of sidewalks, pavement, and surfacing. STD-WALK a ITEM VI GRASSING AND PLANTING 6.01 Scone (a) This item shall consist of performing all labor and furnishing all materials to do the grassing and planting work complete as shown on the plans and specified herein, including ground preparation and fertilizing, seeding, hydro- seeding and mulching, mulching, erosion control netting, tree wells and tree root protection, vines, shrubs and tree planting and transplanting. This work shall also include the maintenance and watering and any necessary replanting. (b) The area within the limits shown on the plans, except the areas occupied by structures, shall be planted with a mixture of grassing seeds and mulched as herein specified. (c) Vines, shrubs and trees shall be placed as shown on the planting plan or as authorized by the Engineer. (d) Grassing shall be seeding and mulching or hydro-seeding and mulching. Mulching shall be straw or hay unless asphalt is shown on the plans or specified in the Special Conditions. 6.02 Ground Preparation (a) After all other construction work is completed and the surface of the ground finished to subgrade the topsoil that was removed and stockpiled as speci- fied in Item I shall be spread over the area to be planted. This topsoil shall be uniformly spread in a layer not less than five inches thick. Additional topsoil from other sources shall be furnished by the Contractor if necessary, to cover the area to be planted to the specified depth. (b) After the topsoil is spread the surface of all areas to be planted shall be prepared by plowing and discing in both direction, when feasible, to a depth of not less than four (4) inches. After removal of all large particles which cannot be broken, the surface shall then be harrowed and cultivated. Plowing and harrowing shall be performed with proper equipment and in such manner as to break up all clods, lumps, or earth balls, and to remove all rocks, stumps, large roots, or other particles so as to provide a suitable planting bed. Hand -ools shall be uses: in inaccessible small areas. cl The entire area to be planted shall be carefull.i finished to exact ling and grade before planting. Care shall be used to shape the surface of the ground proper!,; around structures. (d) Topsoil to be furnished shall be fertile, friable, natural topsoil typical of topsoil of locality. It shall be without admixture of subsoil and shall be reasonably free of stones, lumps, plants, roots, sticks, and other extraneous matte:-, and shall not be used for planting operations while in a frozen or muddy condition. (e) All soil to be used in a tree, shrub and vine pit for planting operations shall be conditioned by thoroughly mixing one part by volume of peat, one part b,; volume of rotted manure and four parts by volume of topsoil. 6.03 7ertilizer a) `tanufactured fer--ilizer shall *De stsndard --omme=__ and sha'- ?n- _^.o- less _nan the percentages b,- Neigh' out in folio :ns table: Nitrogen N 8 Phosphorus P_OS 8 Potash K.0 S A!-' shall oe -_ransnorted _.i ont.ti will insur '3rcDo' rJ 2 at..i iandi_ng (c) Agricultural limestone shall be crushed or ground to such a degree of fineness that 90 percent of the material will pass through a 10 mesh screen and not less than 50 percent of the material will pass through a 60 mesh screen. All such limestone shall also have a neutralizing value of 90 percent calcium carbonate or better. (d) basic slag shall be ground open hearth basic slag containing not less than the percentage by weight of the following ingredients: Total Phosphoric Acid ... 6.00 Iron Oxide ............ 18.50 Magnesium Oxide ......... 5.50 Calcium Oxide ......... 4.00 Manganese Oxide ......... 3.00 Neutralizing Power .....80.00 At least 80 percent shall pass through a 100 mesh screen and at least 90 percent shall pass a 50 mesh screen. (e) Fertilizers shall be applied uniformly into the areas to be planted or improved in such amount and to such depth and according to the methods indicated in the specifications for the various ground covers. The fertilizer shall be well pulverized and free of lumps when applied. In no case shall full strength fertilizer be permitted in direct contact with roots. When fertilizers are applied hydraulically they must be diluted sufficiently as directed so that no damage is done to either seed or established grasses and legumes. Agricultural limestone and basic slag shall be applied in a separate operation but may be incorporated in soil with fertilizers in one operation. 6.04 Seeding (a) Seeding shall consist of furnishing, inoculating and sowing seeds and covering, compacting and maintaining the seeded areas. (b) All seed used shall meet the requirements of these specifications and comply with applicable state laws and rules and regulations promulgated thereunder. Each kind of seed for use either pure, or as a part of mixed seedings, shall be separately packed and delivered to the project in standard see-tight shipping bags, all prominently identified. Each bag shall bear a tag or label certifying to contents, tests and analysis. Seed furnished shall be hulled and scarified where indicated by the letter symbols "H" and "S" respectively. All seeds of legumes, as indicated by letter symbol "N" shall be inoculated just before use, with the appropriate commercial culture manufactured by a reputable concern. Such material shall be approved and used according to the manufacturer's instructions. The following tables specify the quantity by weight of the different seeds required when sown along, their purity and germination. Lbs. Required Xinimum Common Name Per Acre Purit Germinable Bermuda Grass (Unhulled) 30 99 80 Bermuda Grass (Hulled) 20 HS 99 85 Kentucky Blue Grass 40 85 75 Kentuckv 31 rescue 30 99 85 Annual Lespedeza 50 H;; Q5 80 ?eseedins _r-.mson C o%er 3(; H; ?0 85 :'e:lsaco?a 3a'..:a _?0 85 (c) Seed mixtures shall be applied at the rate in pounds per acre and with the seasonal limitations shown in the following table: Seeds April-June July-August September-March Bermuda Grass (Hulled) 12 5 Kentucky Blue Grass 6 Kentucky 31 Fescue 20 20 20 Annual Lespedeza 10 Reseeding Crimson Clover 30 30 White Clover 4 Pensacola Bahia 20 20 20 (d) The Contractor shall notify the Engineer at least twenty-four hours in advance of the time he intends to start inoculating and mixing seed or begin sowing seed and shall not proceed with such work until permission to do so has been given. (e) Fertilizer shall be applied as specified in Section 6.03 and mixed to the depth of preparation as soon as applied. It shall be applied mechanically or by approved hydraulic equipment. The seed bed for all mixed seedings shall be fertilized initially with 2 tons of agricultural limestone, or basic slag and 1500 pounds of grade 8-8-8 fertilizer per acre. (f) Preparatory to sowing, the seed accepted for use shall be inoculated as provided herein. Each kind of seed shall be inoculated separately with the appropriate commercial culture according to instructions of the manufacturer of the material accepted for use, then allowed to surface dry to a free flowing state before mixing or sowing. In general, no greater quantity of seed shall be inoculated at one time than can be sowed by the end of the following working day. All inoculated seed shall be protected from the sun and direct contact with commercial fertilizers. (g) Sowing of seed shall follow promptly after incorporation of fertilizer. Sowing shall be done uniformly at the specified rate by approved mechanical seeders. Hand operated cyclone sowers will be considered mechanical seeders. No sowing shall be done during windy weather, when the prepared surface is crusted, or when the ground is frozen, wet or otherwise in a nontillable condition. (h) Immediately after sowing, the seeded area shall be harrowed, dragged, raked or otherwise worked so as to cover the seed with a laser of soil ?.-inch this::. Care shall be exercised during covering operations to preserve the line, grade and cross-section of the seeded areas and to see that areas adjacent tn pavement, walks, etc., are not left higher than the paved surface. After the seed has been properly covered the seed bed shall be compacted immediately by means o*_ a cultipacker, light roller or approved drag. Rolling or covering of seed may be omitted when seeding is done hydraulically and mulched. (i) The Contractor shall water, fill washes, and otherwise protect anc: maintain the seeded areas until the contract is accepted. Damage by either pedes- trian, vehicular traffic, or other causes shall be repaired by the Contractor. It shall be the responsibility of the Contractor to establish and maintain a satisfactory stand of grass until final acceptance of the project. A satisfactor•: stand of grass shall be defined as a complete cover of living grass (limited to the species of seed that are expected to germinate in the current season). If a satisfactory stand of grass is not established, the area shall be reseeded by the Contractor. Seeded areas shall be mowed as required and when weeds or other undesi:-able vegetation threaten to smother the o'_anted species. ?a) This work shall consist of mulching (covering with hav or straw) those areas indicated on the plans to be grassed in accordance with these specifications. (b) Mulching material shall consist of hav or straw and asphalt complyin;,.; with the following: =. Hav shal'_ be applied at ':h- rite of not less `.. tons per acr,- ar-'. ma, be n.at_ve ?iav o, ':udan `sass, b m ?ed?e. Beds _r _ _ppings or a:. >'..er ep_ab: matz__a. _ow grade, .,-)teed hay unT: for animal consumption is acceptable. Hay or straw shall be applied with a moisture content not more than 15 percent or if the moisture content exceeds 15%, a proportionate increase shall be made in the rate of application. ?. Straw shall be threshed straw of oats, wheat, or rye, applied at the rate of not less than 24 tons per acre. (c) Mulching materials which contain matured seeds of species which would volunteer and be detrimental to the proposed planting shall not be used. (d) Asphalt shall be suitable for mulching and shall contain no petroleum solvents or other diluents toxic to plant growth. It shall be a homogeneous emulsification of refined asphalt suitable for spray application with or without dilution with water and of a type approved by the Engineer. Asphalt shall be included in the mulch only at locations specifically specified or shown on the plans (e) Straw, and hay mulch shall be applied with a mechanical mulch spreader with an attachment designed to apply effectively an asphalt adhesive to the mulch material and to blow the asphalt sprayed mulch by means of a high velocity air stream over the prepared area to form a uniform porous stable blanket held in place by the asphalt adhesive. The spreader shall be designed to break up balls or clusters of the mulch and apply it evenly and uniformly over the surface so as not to exclude penetration of sunlight. (f) Immediately after the area to be mulched has received ground preparation and specified planting, the mulch shall be applied at the rates specified above. Mulch which is too fresh, or excessively brittle, or so decomposed as to retard growth of grass will not be acceptable. The asphalt adhesive shall be applied at a rate of 200 to 250 gallons per acre of undiluted asphalt. (g) Mulch shall not be applied during period of high winds or other un- favorable conditions. Care shall be exercised to protect the public, adjacent property, buildings, curbs, sidewalks, and the like form discoloration by the asphalt adhesive. The Contractor shall be responsible for any such damage to public or private property. Any damage or discoloration to structures shall be repaired without delay at the Contractor's expense. 6.06 c?vdro-Seeding and Mulchin a) Hydro-seeding and mulching shall consist of sowing seeds by hydraulic equipment and covering, compacting, mulching, and maintaining seeded areas. Seeds and hydro seeding shall comply with applicable portions of Section 6.04. Mulching shall comply with applicable portions of Section 6.05. Hydro-seeding and mulching shall be performed at the locations and at the time shown on `he plans and in conformity with these specifications. (b) The following listed specifications shall apply to hydro-seeding and mulching: Ground Preparation Section 6. 02 Fertilizer Section 6. 03 Seed Section 6. 04 Seasonal Limitations Section 6. 04 Mixing & Applying Seeds Section 6. 04 Care During Construction Section 6. 0= Mulching Section 6. ' H dro-seeding sha be performed b• approved equipmen- .resigned for the ourtose. The equipment shall be designed to pump a water- seed- '_noculant uniforml•. over ::ne areas to be seeded. It shall include a power driven agitator to keep the mixture uniform during application. The equipment shall be of sufficient force and capacity to apply a uniform application to the upper limits of all cut slopes and the lower limits of all fill slopes. For hay or straw mulch, equipment shall be as spe.:ified in Section 6.05. --our rimes `he manutacturer' recommended rates o~ -;•.ocul_ant cultur,? used. seers sitali be placed in the. culture so _.__or. and mixed 0 _ mechanical agitator in the hydraulic specified in Section 6.04. (e) Hay and straw mulch shall specified in Section 6.05 immediately 6.07 Erosion Control Netting feeder. Seeds shall be applied at the rate be applied in the manner and at the rates after hydro-seeding. (a) Erosion control netting shall be applied to seeded and mulched ground areas which have a slope greater than 5 to 1. Erosion control netting shall be jute, cotton, or plastic material. (b) Jute netting shall be woven from undyed and unbleached plain single jute yarn, averaging 130 pounds per spindle of 14,400 yards. The yarn shall be loosely twisted and shall not vary in thickness by more than 1/2 its normal diameter. The finished mesh shall be of uniform, open (nominal one inch ) plain weave, furnished in rolls as follows: Width - 48-inches, plus or minus one inch, with 78 warp ends per width of cloth; Length - Convenience lengths, 50 yards minimum, with 41 weft ends per yard; and Weight - Average 1.22 pounds per linear yard, plus or minus 5 percent. (c) Cotton netting shall be woven from undyed and unbleached cotton yarn. The finished netting shall be of uniform open weave forming an open rectangular or square mesh of k to b inch, and furnished in rolls with the following charac- teristics: Width - 48-inches minimum; Length - Convenient lengths, 50 yards minimum; and Weight - Minimum average 0.12 pounds per linear yard of 48-inch wide material. (d) Plastic netting shall be an extruded polypropylene or other acceptable plastic material, extruded in such a manner as to form a net with ;Z to ?1 inch rectangular or square openings with strands of approximately nine (9) millimeters thickness. The netting shall be furnished in rolls meeting the following charac- teristics: Width - 48-inches, minimum; Length - Convenient lengths, 50 yards minimum; Weight - Minimum average five (5) pounds per 1,000 square feet. (e) Staples to hold erosion control netting in place shall be U-shaped and shall be approximately six (6) inches long and one inch wide. Machine made staples shall be of No. 11 gauge or heavier steel wire. Hand made staples shall be made from 1;-inch lengths of No. 9 gauge or heavier steel wire. Erosion control netting shall be placed immediately after completion of ground ?reparation, fertilizing, seeding, and mulching in accordance with these specif_cations. The netting strips shall be rolled out flat, parallel to the direction of flow. ',,,hen 2 or more strips are required to cover an area, they shall overlap 3-inches, minimum. Ends of strips shall overlap 6-inches, minimum, with the upgrade section on top. The upslope end (anchor slot) of each strip shall be buried in 6-inch vertical slots, and soil tamped firmly against it. When, in the opinion of the Engineer, conditions warrant, any other edge exposed to excessive flow shall be buried similarly. (g) The netting shall be spread evenly and smoothly, and in contact with the mulch at all points. It shall be tamped or stapled to assure close contact with the mulch. Each strip shall be stapled in 3 rows; each edge and the center, spaced at not more than 3-feet longitudinally. Ends of strips shall be stapled at 9-inch intervals across their width. '-.) Care during construction shall consist of protection and of repairs made necess b.- eros- ?7.. wind, fire. and/or other causes. Repa:r- shall be such a., -ne condition and trade of the soil as _st:n? prior app-:cation of the netting, restoring damaged ground preparation, refertilizatiot,. and replanting of damaged areas, without additional compensation. The period of care shall continue until acceptance of the contract. Care shall be performed without additional compensation. ?i.08 °xce.lsior Blankets i` E'x-eIs_.): .,_ankets may b e :,e . _nstead o? erosior _ netting an . mulching on ground areas having a slope greater than 5 to 1 or at other locations. (b) Excelsior blankets shall consist of a machine produced mat of curled wood excelsior of 80 percent six inch or longer fiber length, with consistent thickness and the fiber evenly distributed over the entire area of the blanket. The top side of each blanket shall be covered with a photodegradable extruded plastic mesh. The blanket shall be made smolder resistant without the use of chemical additives. (c) The area to be covered by the blankets shall be properly prepared, fertilized, and seeded before the blanket is applied. When the blanket is un- rolled, the netting shall be on top and the fibers in contact with the soil over the entire area. In ditches the blankets shall be applied in the direction of the flow of water, butted snugly at ends and sides and stapled. On slopes the blankets shall be applied either horizontally or vertically to the slope and ends and sides butted snugly and stapled. (d) Staples shall be made of steel wire, 0.091-inches in diameter or greater, "U" shaped with legs six inches in length and a one-inch crown. Size and gauge of staples used shall vary with soil conditions. The staples shall be driven vertically into the ground, spaced approximately two lineal yards apart, on each side, and one row in the center alternately spaced between each side (60 staples on each blanket) a common row of staples shall be used on adjoining blankets. 6.09 Tree Wells and Root Protection (a) This section shall cover (1) the protection of selected trees, shrubs, or other woody plants by tree wells so constructed as to protect the root system and (2) the placing of porous material, consisting of 3/8 to 5-inch aggregate to such depth around the roots as provided by the plans or directed. Tree wells shall be constructed of concrete, rubble masonry, or brick masonry as may be provided on the plans. Such construction shall be performed in accordance with the design and details indicated on the plans and with applicable sections of these specifica- tions. (b) All excavation incidental to and necessary for constructing tree wells shall be so conducted as to avoid injuring the root system. No backfill of any nature shall be placed by the Contractor above the root spread of a tree or plant which it is desired to preserve until a fill of porous materials not less than 3- inches in depth or as directed has first been placed above its roots. (c) The area for tree root protection shah be first cleaned of all vegeta- tion and porous material shall be then spread loosely over the required area. Following the spreading of the porous material for tree root protection, a minimum of from 4 to 5-inches of topsoil shall be spread above the porous fill to bring the area to the finished grade lines designated. (d) Care shall be taken so that trees or shrubs which are to be preserved in place are not scarred or damaged. The root area to be protected shall be the area of ground surface lying within the periphery of the limb spread of the tree. 6.10 Shrubs and Trees (a) Samples of materials proposed to be furnished hereunder shall be sub- mitted to the Engineer for inspection prior to deliverer of materials. All mater- ials delivered hereafter shall conform to accepted samples, which shall be stored on the site and protected until the deli,.,ery of like materials -.as been completed. Shrubs anc. pL ants shall he _nspec-e-- for size and variety. either at the place of growth or after de'li•ery at ~ the of file work; as authorized by the Engineer. No shrubs or plants rejected at place of growth or at. the site of the work shall be used or paid for under the item. Certificates of inspection as required by federal, state or other authorities shall accompany each shipment. e) Plants shall be freshly dug, vigorous, of normal haDi= of growth, free of c.Lsease, _insects _nsec- eggs; and larvae '' - t shall l _an S Sh ""5er grown Undc', liana _,onditions similar -o those .n _>cali_ of projec- neigh;, of plant and branching shall be measured when branches are in normal positions. Caliper shall be diameter of trunk one foot above surface of ground and shall be the determining measurement for trees. Number of canes specified shall be the minimum acceptable. A cane shall be considered a primary stem which starts from or close to the ground or at a point not higher than one-fourth of the height of the plant. Plants shall conform to measurements of plant list in the plans, except that oversize plants may be used at no increase in contract price. Plants shall not be pruned prior to delivery except upon special approval. The variety of any shrub or plant shown on the plans may be changed prior to delivery to another variety of equal cost, at the option of the Engineer. (d) Stakes for supporting trees shall be of sound wood of uniform size, capable of standing in ground at least two years. They shall be at least two inches in diameter and not less than 9-feet in length, except that for trees under 6-feet in height stakes shall be not less than 8-feet in length. Ties shall be strips of canvas not less than 3-inches in width and 10-ounces in weight or equal fabric. Wrapping materials shall be of first quality burlap or waterproof crepe paper not less than 6 or more than 10-inches in width and of suitable strength. (e) Scientific and common plant names as used on the plans conform to Standardized Plant Names prepared for the American Joint Committee of Horticulture Nomenclature. Names of varieties not included therein conform generally with names accepted in the nursery trade. Substitutions will not be permitted, except that if proof is submitted that any plant specified is not obtainable a proposal will be considered for use of nearest equivalent size or variety with an equitable adjustment of contract price. The plants to be furnished and planted are shown on the plans. 6.11 Digging and Handling Plants (a) Dig baled and burlapped plants, with firm, natural balls of soil, of a diameter not less than specified, and of a depth to encompass sufficient fibrous and feeding roots to insure full recovery and development of plants. No plant moved with a ball shall be planted if the ball is cracked or broken, except upon special approval. (b) Dig bare rooted plants with spread of roots not less -han specified, an'. a depth sufficient to insure full recovery and development of _lants. Bare roots shall b,- puddled. 6.12 Planting Shrubs and Trees (a) Remove rock or other underground obstructions to the depths necessary to permit proper installation of planting, unless other locations are selected by the Engineer. (b) Stake plant locations and secure approval before exca•:ating pits, making any adjustments necessary; locate no plants, except vines, closer than two feet to pavement or structure, (c) Excavate pits in circular outline, with vertical s_-Jes, for all plants except hedge plants. (d) Tree pits shall be at least two feet greater in diameter than diameter of ball or spread of roots; and at least two feet depth. rib pits shall b it least one foo- greater in diameter thar. diame_-r bai: _pra of roots an t least one foot in deu--'^. (e) Set plants in :enter of pits, placin7 bai_ roo=- -aver of top- soil at least two inches in depth, adjusting depth as necessa_-:: so that crown of plant will stand at finished grade; set hedge plants, evenly spaced, along center line of trench. Compact soil around balls or roots of plants a:-.d water thoroughly. Form ridge of soil around edge of pit to facilitate water'-::,, Use clean soil excavation from plant pits between shrub pits, if arranged i..--ouns. as necessar•. -o ri planted areas to finished t.;rade ir(d ..ispo;e of e: a:at.ed soil 1 .?. r C. .' C..=ti'. 3::0 betw-'. e:. D_ _.s .o .1 '_1 r'p and neat . outline. (f) Prune plant in accordance with standard horticultural practice. Mulch plant pits one-inch deep, using well rotted manure lightly incorporated in soil. (g) Stake trees as follows: setting each stake vertically and at least one-third of its length in ground, approximately 12-inches from trunk; guy trees to upper end of stakes with canvas ties folded to a 14-inch width. Single stake trees under two inches in caliper if so indicate by drawings. Double stake each tree two or three inches in caliper setting each stake vertically at least one- third of its length in the ground, approximately 12-inches from trunk. Guy trees to upper end of stake with canvas ties folded to one and one-half inches in width. (h) Wrap trunk of trees, spirally to height of second branches and tie the wrapping in place with suitable cord. 6.13 Guaranty and Replacements (a) Replace during the next planting season all dead plants and all plants not in vigorous, thriving condition and at no additional cost. Plants used for replacement shall be of the same kind and size specified in plant list and shall be furnished, planted and mulched as specified. (b) The Contractor shall maintain planting at his own expense until final acceptance of the project or until 90 days after planting. Maintenance shall consist of preserving, protecting, watering, replacing, and such other work as may be necessary to keep the work in a satisfactory condition. 6.14 Payment (a) No separate payment will be made for grassing and planting performed under these specifications but this work shall be included in the lump sum payment for the Treatment Plant/Pumping Station/other facilities, as applicable. STD-GRAS ITEM VII MISCELLANEOUS METAL WORK 7.01 Scope (a) The iron castings covered by this item shall consist of furnishing and installing special manhole frames and covers, special inlet frames and covers, sidewalk frames and covers, access ladder rungs and all other iron castings not specifically covered elsewhere, as shown on the plans and as specified herein. It shall not include standard manhole frames, covers and steps installed on standard manholes, inlet frames and covers installed on inlet structures, or standard and special pipe fittings, all of which items of work are covered elsewhere in these specifications. (b) The structural steel work covered by this item shall consist of furnishing, erecting and painting structural steel, including ladders, screens, base plates, bearing plates, loose lintels, anchor bolts, field rivets and bolts, erection bolts, steel frames and covers, and all other structural steel not specifically covered elsewhere, as shown on the plans and as specified herein. It shall not include concrete reinforcement, spiral stairs or structural steel parts of gates, machinery or mechanisms, all of which items of work are covered elsewhere in these specifications. (c) The structural aluminum work covered by this item shall consist of furnishing and erecting structural aluminum ladders and safety cages and all other structural aluminum not specifically covered elsewhere, as shown on the plans and as specified herein. It shall not include aluminum gratings nor parts of machinery and mechanisms, and handrails, all of which are covered elsewhere in these specifications. (d) The z rating work covered by this item shall consist of furnishing and installing gratings, including all angles, anchors and other incidental fastenings, as shown on the plans and as specified herein. (e) The handrail work covered by this item shall consist of furnishing and installing pipe railings, complete in place, in the types and sizes shown on the plans and as specified herein. It shall not include handrails installed as part of =,, equipment or mechanisms, which item of work is covered elsewhere in these specifications. It shall not include handrails inside the buildings, unless otherwise shown on the plans, which item of work is covered elsewhere in these specifications. (f) The fence work covered by this item shall consist Df furnishing anti installing fences complete with posts, braces, and gates as shown on the plans and as specified herein. 7.02 Materials (a) Cast iron for iron castings shall conform to the requirements for AST`! Specification A48, Class 35, for Gray Iron. These specifications shall cover manufacture, physical properties, and testing. Malleable iron shall conform to the minimum requirements of ASTM Specification A197, for Cupola Malleable Iron. (b) Structural steel, rivet steel, and other metals required under this item of the specifications shall conform to the requirements of the Anerican Institute cf Steel Construction Specifications for the Design, Fabrication and Erection o: f,_ 3uildings. Steel fra::ies and covers shal of the types a:-.,. s is snow-. c., e b ans . ,c) Structural aluminum required under this item of specifications shall ?,- alloy and temper 6061-T6. Non-structural aluminum applications shall be alloy and temper 6063-T6. (d) Gratings shall be the plank type constructed of aluminum. All gratinv, shall be constructed to carry a uniform live load of 175 pounds per square foo` a i:i.ixim!us deflection of 1_!160 of the span, unless otherwise shown on tho !ar..: op e.n.i: i-s for pipes, etc. , shai_ be banded and _i rc,~ings shall 1:) _i-e.: s...-.'_ons of such size tha- each section ;ray: .,-moved wi?'aou- pressed steel arm designed to extend at a 450 angle and slotted to carry three (3) evenly spaced strands of barbed wire. The top strand of wire shall be located twelve (12) inches above the height of the fence fabric. Barbed wire shall be securely fastened in the slots of heavy wire pins. End and corner post extension ms shall be of No. 11 gauge (minimum thickness) pressed steel or heavy malleable iron of sufficient structural strength to support the barbed wire stretched to proper tension. They shall be similar to the intermediate extension arms and shall be riveted to the post. Gate frames shall be 1.90" OD pipe connected with fittings riveted at each corner. Each frame shall have 3/8" diameter adjustable rods. Fabric which matches the fence shall be installed on the frame by means of tension bars and hook bolts. Gate height shall be the same as that of the fence (7 feet including three strands of barbed wire). Gates shall have positive type latching devices with provisions for padlocking and drive gates shall have a center plunger rod, catch, and semiautomatic outer catches. All posts, rails and appurtenances shall be hot-dipped zinc coated steel complying with ASTM Specification A120, A123, or A153 as applicable. Pipe posts shall have tops which exclude moisture. Fabric shall be fastened to line posts with six (6) gauge wire clips every 14-inches; to terminal, corner, and gate posts by integrally weaving into the post or by using 1/4" x 3/4" tension bars tied to the post every 14-inches with eleven (11) gauge 1-inch wide steel bands and 3/8" diameter bolts and nuts; and to tension wire with eleven (11) gauge hog rings every 24-inches. (g) Wire fences, including two lines of barbed wire, shall stand 411 feet high above finished grade when erected. Fabric shall be galvanized steel standard mesh hog and cattle wire 42-inches high. Top and bottom wires shall be ten (10) gauge and intermediate and stay wires shall be twelve and one-half (12k) gauge. The two lines of barbed wire shall be galvanized steel of the 4 point pattern composed of 2 strands of twelve and one-half (12?i) gauge line wires with 14 gauge barbs spaced 5-inches on center. Posts shall be of wood or steel at the option of the Contractor. Wood posts shall be of Southern Yellow Pine pressure treated with either Grade 1 Creosote or Creosote-Coal Tar solution conforming to the require- ments of ASTM Specification D390 for Creosote, or D 391 for Creosote-Coal Tar solution. The preservative shall be applied under pressure to refusal, using the full c?.Ll process in accordance with the Standard Methods of the American Wood Preser-:ers Association. Wood posts shall be 7-feet in lengt'r, and corner and line posts s^.all be 4-inches and 3-incises in diameter, respectivel_.'. Steel corner and pull posts shall be 2-7/1" OD galvanized standar pipe. Steel fine posts shall be galvanized standard tee sections. Steel posts shall be , in length. Post spacing shall be not greater than 10-feet. Gates shall be chain link fence gates as specified in Paragraph 7.02(e) of these specifications. 7.03 Shoo Drawings (a) Detailed shop and erection drawings giving complete information necessary for the fabrication and erection of the component parts, including the location, type, size and extent of all welds and clearly distinguishing between shop and field rivets, bolts and welds, shall be submitted or the review of the Engineer. However, review of shop drawings shall not relie•:= the Contractor of responsibility: for the correctness of all detailed dim,nsie-,.s and the correct ln. o a__ -par-_s. Mat.?.-Lass shall ^o,. be _)r_..a-ed D_... _ JC?:J`.'al of tn-- 0_ =abrication -.onstruction and Erection (a) Castings shall be sound, smooth, clean and free from blisters and other defects. No plugging of defective castings will be permitted. :x.11 unfinished edges of castings shall be neatly cast with suitable ro,_inded inci all inside .in^1es ha` e the plans. smoothness ?2161ed. A1: disassembling the pipes which pass through it. Aluminum planks fabricated in sections shall have end closure strips. Aluminum plank type grating shall be as manufactured by Borden Metal Products Company, Washington Aluminum Co., or equal. (e) Handrails shall be Type I or Type II at the option of the Contractor unless Type I or Type II is specifically shown on the plans. All handrails shall meet the requirements of OSHA. Type I handrails shall be a welded system fabricated of 14-inch OD, Schedule 40 aluminum pipe which conforms to the requirements of ASTM Specification 6063. Welding shall be the Tungston type-inert gas method and shall be by a welder certified for aluminum work. Finish shall be "mill finish" without deep scratches or burrs. Type I handrails shall be a mechanically fastened system. Rails, posts, and formed elbows shall be fabricated of extruded 14-inch OD, Schedule 40 aluminum pipe which conforms to the requirements of ASTM Specification 6063. All other aluminum parts shall be fabricated of cast aluminum which conforms to the requirements of ASTM Specification 6063 or 6061. Fittings shall be one-piece castings machined to final shape. All fasteners shall be furnished by the handrail manufacturer and shall be of Type 305 stainless steel. Aluminum components shall have a clear stain anodized finish on all exposed surfaces. The anodized coat thickness shall be 0.4 mils on cast aluminum and 0.7 mils on extruded aluminum. Aluminum pipe and fittings shall be individually packed for shipment with plastic film which shall not be removed until after installation and immediately prior to final inspection. Post collars shall be installed on posts which are set in concrete. Where base mounting is shown on the plans, base flanges shall be machined from extruded aluminum. Where posts are fastened to stair stringers, they shall be mounted on bases machined from extruded aluminum. Type II handrails shall be ReynoRail II as manufactured by Reynolds Metals Co., Interna-Rail as manufactured by Hollaender Mfg. Co., or equal. (f) Chain link fences, including three (3) strands of barbed wire, shall stand seven (7) feet high above finished grade when erected. Fabric shall be two (2) inch mesh, nine (9) gauge aluminum coated Class II chain link complying with ASTM Specification A491 or Class II galvanized chain link complying with ASTM Specification A392. Tensile strength of fabric wire shall be 80,000 PSI minimum. Barbed wire shall consist of two 12y gauge stranded line wires with a minimum aluminum coating weight of 0.30 ounces per square foot of wire surface and 14 gauge alumimun barbs in a 4 point pattern on 5-inch centers; or barbed wire shall have a Class II_ galvanized coating conforming to STS! Specification i ". Top and bottom :ens'on wires shall be 7 gauge spring coi: wire with Class .I aluminum coat complying with AST.t Specification A491 or Class II galvanized coat complying with ASTM Specification A392. End, corner and pull posts shall be of 2-71/8-inch OD pipe 5.79 pounds per foot, or 3Y' x 3L" roll formed sections with integral fabric loops, 5.14 pounds per foot. Line posts shall be H-columns weighing 2.7 pounds per foot or 2-3/8-inch OD Schedule 40 pipe. Posts for swing gates shall be of the following nominal sizes and weights for single swing gates or one leaf of double gates; Post Weight Cate Width Post Size Lbs/Lin. Ft. Up to 6' 3y" x 3Y' roll form section 5.14 or 2-7/8" OD Pipe 5.79 6 to OD Pipe 9.11 tp J 'S" 7D ?1pe Lp 97 '0 ?osts _;na__ be evenly spaced in the :ine of fence no farther apart than 10-feet or, centers. Cate posts shall extend to the full height of the fence. Braces shall be 1-5/8" OD standard pipe weighing 2.27 pounds per lineal foot and shall be installed midway between the top tension wire and the ground. They shall extend from each terminal post to the first adjacent line post. 3-races shall h- securely hastened os hea" pressed ,tee: connections, en trussed tr. _ine post to ss _od, - ompla" ntr.rmedi - -= -en o- Inv.c x-,11 1 0 ' aressed -?_ ,:a. _ a` . -)ase with anchor bolts shall be of Type 305 stainless steel. (f) Chain link fences shall be erected in a workmanlike manner by skilled mechanics, experienced in erection of this type fence. The fence shall be erected to lines and grades shown on the plans. All posts shall be set in concrete foundations in the ground to a minimum depth of three (3) feet. Diameter of the foundations shall be a minimum of nine (9) inches except for gate posts on which the minimum diameter shall be three (3) times the outside diameter of the post. Foundations shall be Class B concrete. Foundations shall extend approximately two (2) inches above grade and shall slope away from the post to assure proper drainage. The fabric and barbed wire shall be stretched to proper tension between terminal posts and securely fastened to framework members as specified herein- before. The bottom of the fabric shall be held uniformly two (2) inches above finished grade. (g) Wire fences shall be erected in a workmanlike manner to the lines and grades shown on the plans. Where wooden posts are used, corner and pull posts shall be braced as shown on the plans. Where steel posts are used, corner and pull posts shall be braced and set in concrete foundations in the ground to a minimum depth of 2 feet. Diameter of foundations shall be 9-inches. The fabric and barbed wire shall be stretched to proper tension between terminal posts and securely stapled or fastened to posts. 7.05 Coating and Painting (a) Miscellaneous metals shall be painted in accordance with the applicable requirements of Item VIII of these specifications. (b) Cast iron frames and covers shall be cleaned by shot blasting and shall not be shop painted. 7.06 Payment (a) No separate payment will be made for Miscellaneous Metal Work furnished and installed under these specifications, but this work shall be included in the lump sum payment for the Treatment Plant/Pumping Station/other facilities, as applicable. STD-MISC castings shall be annealed to remove internal stress before being machined. All castings shall have the mark number and heat number cast on them. All parts called for on the plans as galvanized shall be coated to conform to the requirements of ASTM Specification A123. Cast iron frames aid covers shall be of the types and sizes shown on the plans. Iron castings shall be installed as shown on the plans. All surfaces shall be accurately set to the line and grade shown on the plans and carefully leveled unless otherwise shown. Castings to be embedded in concrete shall be firmly and properly supported until the concrete has been placed around them and hardened. Castings to be embedded in brick masonry shall be inserted as the work progresses. Care shall be exercised in bolting castings to prevent misalignment or springing of any of the parts. (b) Fabrication and workmanship for structural steel, including welding, shall conform to the requirements of Part V, Fabrication of the American Institute of Steel Construction Specification for the Design, Fabrication and Erection of Structural Steel for Buildings. Bearing surfaces shall be planed to true beds. All columns and bearing stiffeners shall be milled to give full bearing over the cross section. Column base plates 2-inches or less in thickness may be used without planing; plates between 2-inches and 4-inches in thickness may be straightened by pressing, or they may be planed, plates over 4-inches thick must be planed. It shall not be necessary to plane bottom surfaces of plates on grout beds. Methods of erecting structural steel shall conform to the requirements of Section 7, Erection of the American Institute of Steel Construction Specifications for the Design, Fabrication and Erection of Structural Steel for Buildings. Column bases and beam plates 12-inches x 12-inches and larger shall be set on steel wedges or angle screeds to accurate elevations approximately 14-inches clear of masonry and shall be grouted in place. Wooden wedges shall not be used. All base plates over 20-inches shall be set on angle screeds. All base plates over 30-inches in both directions shall have two 2-inch grout holes. Steel surrounding elevator shafts shall be allowed a variation of 1:1,000 from plumb. All other steel shall be level or plumb within a tolerance of 1:500. Loose lintels shall be placed in masonry or formed in concrete as the work progresses, Field errors shall not be corrected by burning unless specifically so authorized by the Engineer. (c) Structural aluminum ladders and safety cages shat: ;lave bolted con- nections using stainless steel bolts, nuts, and' -washers. (d) 1.dhere aratinzs are installed in concrete, i sha:_ be supported by anchored bearing angles on all sides. Bearing ang'ies shah be -hr same material as the grating. The width of the horizontal le-7 of the bear'_:._. angles shall be equal to at least twice the depth of the grating it supports. -ompleted sections shall be level and true so as to rest firmly on the bearing angles along the entire contact surface. Bearing angles and anchors shall be accurate-,: set to the line and grade shown on the plans, leveled and rigidly supported by suitable means until the concrete has been placed around them and has hardened. Vnere aluminum angles are to be in contact with concrete, the contact surfaces sha'l'l oe painted with 1 coat of 89 Tneme-Grip Prime plus 2 coats of 449 7nemec Heavy D!:-:r Black or equal. Where adjustable fastening devices, clips, etc., are required for connections to I-beams or other work, such fastenings or devices shall be ills-alled as detailed on the shop drawings. (e) Handrails shall be installer in the s'_::es and i- - __?clations shown on tha plans. Handrails sham be riJid a•,.! -rue _-1es s:. aos-., shall be sint,le unsoliced a.ve :? eces -h -, __ .a _ e ie ., ., possible ld a single unspiiced Ler,th siia-1 he at_acne. _.> _i .,osts where possible. The lower rail shall be a single unscliced leng-h `.,,-..een posts. Post spacing shall not exceed 6'-0" on center. Posts supported b•. concrete shall be inserted in a 2?i-inch OD aluminum pipe sleeves, previously se- during placing of concrete and caulked with non-shrink grout. Pipe sleeves and. -_.e bottom of posts which are in contact with concrete or rout shat: !Jain-ed ..a `. 0p :;'. pain,.. Toe. ' _.. .. ..ne' COaC Of COai. 3_'_? ?nstalle(.i rails o!. screws, and ITEM VIII PAINTING 8.01 co e (a) The work included in this item shall consist of furnishing materials and the performance of painting work and other work incidental thereto as required for the proper painting of exposed piping, miscellaneous metals, mechanical equipment, buildings, and exposed electrical conduit specified in Item IV, VII, IX, X, and XI, respectively, of these specifications. (b) Galvanized steel and non-ferrous metals, concrete, and concrete blocks shall not be painted unless such painting is specified in the Special Conditions, Item X (Buildings) or Item XI (Electrical Equipment and Wiring). (c) This item shall not include factory baked-on enamel nor other special factory applied finishes. 8.02 Surface Preparation (a) Surfaces to be painted shall have all rust, dust, mill scale, and other foreign substances removed prior to painting. Surfaces shall be clean and dry when painted. (b) Ferrous metal surfaces shall be prepared for painting in accordance with one of the following specifications of the Steel Structure Painting Council which is specifically designated hereinafter in Paragraph 8.08, Painting Systems. (1) SSPC-SP 1 Solvent Cleaning (2) SSPC-SP 2 Hand Tool Cleaning (3) SSPC-SP 3 Power Tool Cleaning (4) SSPC-SP 5 White Metal Blast Cleaning (5) SSPC-SP 6 Commercial Blast Cleaning (6) SSPC-SP 7 Brush-off Blast Cleaning (7) SSPC-SP 8 Pickling (8) SSPC-SP 10 Near White Blast Cleaning (c) 'Where surfaces are to be painted with field coats onlv, surfaces shall be prepared in the field. (d) Galvanized steel and non-ferrous metal surfaces shall be cleaned in accordance with Specification SSPC-SP 1 Solvent Cleaning. Solvents shall be mineral spirits or other paraffin-free solvents having a flash point higher than 100°F. (e) Wood surfaces shall be thoroughly cleaned of dust, dirt, oil, grease, and other foreign substances. Wood trim shall be sandpapered to a fine finish and wiped clean of dust. (f) Concrete concrete blocks and wallboard or other drywall surfaces shall be cleaned so that they are free of dust, form oil, curing compound, and any other foreign matter which will interfere with the bond of the paint materials. Concrete floors shall be etched with a solution of muriatic acid (15% or 20% or stronger) until a granular effect is obtained. After etching, the surfaces shall be flushed clean with water. Concrete wall surfaces which are to be submergec. shal-` be sandblasted so that all loose materials are removed and a granular effec` _s ob_._ned. Sandblasting shall be similar `o Brush-off Blast Cleaning (SSPC-S_'' ,surface preparation shall not begin on poured concrete surfaces until the coneret has been in place at least 28 days. Concrete surfaces shall not be coated when the moisture content is above 14 percent when checked with a drywall moisture meter. 3.03 Paint Materials al ?ain7 materials shall be as manufactured by Indurall Coatings, Inc _..._.._,ham.. Alabama; Kop-Coat, 7 nc. , St. Louis. Missouri. ; Tnemec Company, Inc 8.07 Field _Touch-U (a) Abrasions and scratches in prime coats, field welds, etc. shall be cleaned in accordance with SSPC-SP 2 Hand Cleaning, SSPC-SP 3 Power Tool Cleaning, or SSPC-SP 7 Brush-off Blast Cleaning. Cleaning must remove all rust and other foreign substances. Immediately after cleaning, these areas shall be given one coat of the primer specified hereinafter in Paragraph 8.08, Painting Systems. 8.08 Painting Systems (a) Painting systems shall consist of surface preparation, pretreatments, prime coats, field touch-up, and finish coats. Surface preparation and pretreat- ments shall conform to the requirements of Paragraphs 8.02 and 8.05, respectively, of this item of the specifications. Field touch-up is required when the prime coat is shop-applied. FERROUS METALS (b) PAINTING SYSTEM NO. 1 shall be applied to NON-SUBMERGED INTERIOR AND EXTERIOR FERROUS METAL SURFACES NOT SUBJECT TO SEVERE MOISTURE including handrails, air blowers, air piping, electric motors, cranes, hoists, rails, doors and frames, and miscellaneous metals. Painting System No. 1 shall be a phenolic/polyurethane, epoxy/acrylic, or alkyd system consisting of: (1) Surface preparation, Commercial Blast Cleaning (SSPC-SP 6) and (2) Indurall Induron P30 Universal Primer shop primer (one coat) applied to a 1.5 minimum dry mil thickness (MDMT) per coat; field touch-up using shop primer materials; and two field coats of Indurall Induron Indurlux Polyurethane Enamel applied to a 1.5 MDMT per coat, or (3) Kop-Coat 340 Gold Primer shop primer (one coat) applied to a 2.0 MDMT per coat; field touch-up using shop primer materials; and two field coats of Kop-Coat 600 Acrylic applied to a 1.5 MDMT per coat, or (4) Tnemec 37H Chem-Prime H.S. shop primer (one coat) applied to a 2.: MDMT per coat; field touch-up using shop primer materials; and :-o field coats of Tnemec Series 2H Color Hi-Build Tneme-Gloss applied to a 2.0 MDMT per coat. (c) PAINTING SYSTEM NO. 2 shall be applied to NON-SUBMERGED INTERIOR AND EXTERIOR FERROUS METAL SURFACES SUBJECT TO SEVERE MOISTURE including clarifier and other basin bridges, pumps, and water, sewage, and sludge piping and valves. Painting System No. 2 shall be a epoxy/aliphatic polyurethane system consisting of: (1) Surface preparation, Commercial Blast Cleaning (SSPC-SP 6) and (2) Indurall Perma-Clean II Epoxy Primer shop primer (one coat) appliec'. to a 2.0 MDMT per coat; field touch-up using shop primer materials; Indurall Perma- C1ean -1 System intermediate field coat (one coat) applied to a =.0 MDMT per coat: and Indurall Indurethane :500 Enamel final - eld coat 'one coat) applied to a MDMT per coat, cr (3) Kop Coat Gold Primer shop primer (one coat) applied to a 2.0 MDMT per coat; field touch-up using shop primer materials; Kop Coat Hi-Guard Epoxy Coating intermediate field coat (one coat) applied to a 4.0 MDMT per coat; and Kop Croat 1122BRS Linear Polyurethane final field coat (one coat) applied to a 2.0 MDMT per coat, or North Kansas City, Mo.; whose products are specified by name and type in each painting system; paint materials of the same type and quality specified as manufactured by Sherwin-Williams Co., Devoe & Raynolds Co., The Valspar Corp., or equal. All paint materials shall be supplied by the same manufacturer. (b) Paint materials shall be in original sealed containers bearing the manufacturer's labels. Colors, where not specified, will be selected by the Engineer. (c) Paint materials shall be stored and mixed in an area designated exclusively for the purpose. The area shall be located away from open flames, be well ventilated, ambient temperature be not allowed to drop below 450F, and shall comply with the requirements of OSHA. 8.04 Paint Application (a) The Contractor shall furnish the services of a trained field repre- sentative of the paint manufacturer to advise painters on the usage of all paints. Field painting will not be allowed until this representative is on the project site. Painting methods shall be in accordance with the plant manufacturer's written recommendations. (b) Painting shall be done on clean and dry surfaces in a manner to produce an even film of uniform thickness and color, free of holidays, voids, pinholes, brush marks, laps, runs, and other visible defects. Edges, corners, crevices, and ledges shall be finished with the same full coverage as the visible surfaces. Each coat shall be dry before the application of additional coats. (c) Prime coats shall be applied to metal surfaces no longer than eight hours after cleaning. (d) Paint shall be applied when the substrate temperature and ambient air temperature is a minimum of 50°F and is expected not to decrease for at least two hours after application. The substrate temperature must be a minimum of 50F above dew point for a period of at least two hours after application. (e) All surfaces adjacent to painting operations shall be protected to prevent damage or discolorations by splashing or dripping paint, brush contact, overspray, etc. All hardware escutcheons, electrical device plates, etc., shall be removed before painting. Any paint spots or drippings, oils, or stains on adjacent painted, or unpainted surfaces shall be removed and a'_'- surfaces left in good condition. (f) Galvanized steel and non-ferrous metal materials which are to be painted and which will be embedded in, or covered by other construction shall have their surfaces prepared and prime coat applied after fabrication and prior to instal- lation. 8.05 Pretreatments (a) Surfaces which require pretreatment prior to the application of the prime coat shall be given such pretreatment as specified hereinafter and as recommended by the paint manufacturer. (b) Galvanized steel and non-ferrous metal surfaces shall be pretreated as specified hereinafter in Paragraph 8.08, Painting Svstems. (c) Wooden surfaces which have knots and pitch streaks ;where such are allowed . shall be sealed with one coat of sealer equal ,estern Pin,• Associa=ion formula, WP-578, or white shellac varnish. No door surfaces including edges, shall be sealed with one coat of sealer immediate:,: after fitting. 8.06 Prime Coats (a) Prime coats shall be applied in the shops of the oioe manufacturer, materials fabricator, and equipment manufacturer or in the _'_e'_d as specified :Zereinatar in Paragraph 8.08, Painting Svstems. a- (2) ndu a U Super Latex field coats one gallon per 300 square feet per coat, or (3) o - oat 600 Acrylic field coats one gallon per 300 square feet per coat, or (two coats) applied at a rate of (two coats) applied at a rate of (4) ne c Tneme-Cryl field coats (two coats) applied at a rate of one gallon per 300 square feet per coat. WOOD (g) PAINTING SYSTEM N0. 6 shall be applied to INTERIOR WOOD SURFACES. Painting System No. 6 shall be an alkyd or epoxy/alkyd system consisting of: (1) Indurall 101 Primer, White H-1400 field primer (one coat) applied at a rate of one gallon per 350 square feet per coat and two field coats of Indurall Alkisheen Semi-Gloss Enamel applied at a rate of one gallon per 400 square feet per coat, or (2) Kop-Coat 340 Gold Primer field primer (one coat) applied at a rate of one gallon per 400 square feet per coat and two field coats of Glamortex 501 Enamel applied at a rate of one gallon per 400 square foot per coat, or (3) Tnemec 36-603 Undercoater field primer (one coat) applied at a rate of one gallon per 400 square feet per coat and one field coat of Tnemec 23-Color Enduratone applied at a rate of one gallon per 400 square feet. (h) PAINTING SYSTEM NO. 7 shall be applied to EXTERIOR WOOD SURFACES. Painting System No. 7 shall be an alkyd/latex or alkyd system consisting of: (1) Indurall 101 Primer, White H-1400 field primer (one coat) applied at a rate of one gallon per 350 square feet per coat and two field coats of Indurall Super Latex applied at a rate of one gallon per 300 square feet per coat, or (2) Kop-Coat Rustarmor Speed thinned 20 percent with Kop-Coat Thinner 4000 field primer (one coat) applied at a rate of one gallon per 500 square fee:. per coat and two field coats of Rustarmor Speed applied at a rate of one gallon per 400 square feet per coat, or (3) Tnemec 36-603 Undercoater field primer (one coat) applied at a rate of one gallon per 400 square feet per coat and one field coat of Tnemec 23-Color Enduratone applied at a rate of one gallon per 400 square feet. CONCRETE (i) PAINTING SYSTEM NO. 8 shall be applied to SUBMERGED CONCRETE SURFACES only when specified in the Special Conditions. Painting System No. 8 shall be all epoxy system consisting of: 1) Surface preparation, sandblasting (See Paraz=aph 8.02(f)), ar(: 2) Epoxy (100%) filler or grout applied at a rate to properly fill - ,l:-voids and :o produce a smooth surface and two field coats of Indurall Induron Perma-Clean II Semi-Gloss Epoxy applied at a rate of 5.0 MDMT per cost, or ;3) Epoxy (100%) filler or grout applied at a rate to properly fill th' voids and .o produce a smooth surface and two field coats of Kop-Coat HI-GAR_ ao `1D`1T per coat, or •. 19 (4) a ec Series 66 Epoxoline shop primer (one coat) applied to a 2.0 MDMT per coat; field touch-up using shop primer materials; Tnemec Series 66 Epoxoline intermediate field coat (one coat) applied to a 4.0 MDMT per coat; and Tnemec Series 70 Endura-Shield final field coat (one coat) applied to a 2.0 MDMT per coat. (d) PAINTING SYSTEM NO. 3 shall be applied to FERROUS METAL SURFACES SUBMERGED IN POTABLE WATER including screens, clarifier and sludge thickener mechanisms, settling basin equipment, weirs, troughs, pipe, valves, gates, and miscellaneous metals. Painting System No. 3 shall be an epoxy system certified by EPA or NSF and consisting of: (1) Surface preparation, Pickling (SSPC-SP 8) or Near White Blast Cleaning (SSPC-SP 10) and (2) Indurall Induron 54 Epoxy Primer shop primer (one coat) applied to an 5.0 MDMT per coat; field touch-up using shop primer materials; and two field coats of Indurall Induron 54 Epoxy Intermediate/Finish applied to an 5.0 MDMT per coat, (3) Kop-Coat 340 Gold Primer shop primer (one coat) applied to a 3.0 MDMT per coat; field touch-up using shop primer materials; and two field coats of Kop-Coat HI-GARD Epoxy applied to a 6.0 MDMT per coat, or (4) Tnemec 20-1255 Pota-Pox shop primer (one coat) applied to a 5.0 MDMT; field touch-up using shop primer materials; and two field coats of Tnemec 20- AA90 Pota-Pox Finish applied to a 5.0 MDMT per coat. (e) PAINTING SYSTEM NO. 4 shall be applied to FERROUS METAL SURFACES SUBMERGED IN WASTEWATER including screens, clarifier and sludge thickener mechan- isms, settling basin equipment, weirs, troughs,, pipe, valves, gates, and miscel- laneous metals. Painting System No. 4 shall be an epoxy system consisting of: (1) Surface preparation, Pickling (SSPC-SP 8) or Near White Blast Cleaning (SSPC-SP 10) and (2) Indurall Induron Prima-Clean II Epoxy Primer shop rimer (one coat) applied to an 5.0 MDMT per coat; field touch-up using shop primer materials; and two field coats of Indurall Induron Perma-Clean II Semi-Gloss Epoxy applied at a rate of 5.0 MDMT per coat, or (3) Kop-Coat 340 Gold Primer shop primer (one coat) applied to a 3.0 MDMT per coat; field touch-up using shop primer materials; and two field coats of Kop-Coat HI-GARD Epoxy applied to a 6.0 MDMT per coat, or (4) Tnemec 104-1255 H.S. Epoxy shop primer (one coat) applied to a 5.0 MDMT per coat; field touch-up using shop primer materials; and two field coats of Tnemec 104 Color H.S. Epoxy applied to a MDMT of 5.0 MDMT. GALVANIZED STEEL AND NON-FERROUS METALS *7) PAINTING SYSTEM NO. 5 shall be applied to GALVANIZED STEEL AND NON- FERROUS METAL SURFACES only when specified in the Special Conditions, Item X (Buildings), or Item XI (Electrical Equipment and Wiring). Painting System No. 5 shall be a latex or acrylic system consisting of: 1) Surface Preparation, Solvent Cleaning (SSPC-S? '_) and 0, of one gallon per 300 square feet per coat, or (4) e c Series 54 Latex Masonry Filler first field coat (one coat) applied at a rate to properly fill the voids and produce a smooth surface and two field coats of Tnemec Series 6 Tneme-Cryl applied at a rate of one gallon per 300 square feet per coat. (m) PAINTING SYSTEM NO. 12 shall be applied to WALLBOARD OR OTHER DRYWALL SURFACES. Painting System No. 12 shall be a latex, alkyd, or acrylic system consisting of: (1) Surface preparation, (See Paragraph 8.02(f)), and (2) Indurall Vinasheen Superior Interior Flat Finish field coats (two coats) applied at a rate of one gallon per 300 square feet per coat, or (3) Kop-Coat Glamortex 501 thinned 10 percent with Kop-Coat Thinner 4000 field coats (two coats) applied at a rate of one gallon per square feet per coat, or (4) Tnemec Series 6 Tneme-Cryl field coats (two coats) applied at a rate of one gallon per 300 square feet per coat. 8.09 Standard Specifications (a) This item, Item VIII, is a standard specification for painting water and wastewater treatment plants and pumping stations and may indicate items or surfaces to be painted which are not applicable to each project, in which case the painting of such items or surfaces shall be disregarded. 8.10 payment (a) No separate payment will be made for painting performed under these specifications, but shall be included in the lump sum payment or payments for the Treatment Plant/Pumping Station/other facilities, as applicable. STD-PANT A (4) Tnemec 63-1500 Filler and Surfacer first field coat (one coat) applied at a rate to properly fill all voids and produce a smooth surface; Tnemec 104-1255 H.S. Epoxy intermediate field coat (one coat) applied to a 5.0 MDMT per coat; and Tnemec 104-Color H.S. Epoxy final field coat (one coat) applied to a 5.0 MDMT per coat. (j) PAINTING SYSTEM NO. 9 shall be applied to CONCRETE FLOOR SURFACES only when specified in the Special Conditions or Item X (Buildings). Painting System No. 9 shall be an epoxy system consisting of: (1) Surface preparation, etching (See Paragraph 8.02(f)), and (2) Indurall Induron Perma Clean II Finish Epoxy field coats (two coats) applied to a 2.0 MDMT per coat, or (3) Kop-Coat Glamorglaze 200 Epoxy field coats (two coats) applied to a 2.0 MDMT per coat, or (4) Tnemec 67-Color first field coat (one coat) applied to a 2.0 MDMT per coat and Tnemec S67-Color final field coat (one coat) applied to a 2.0 MDMT per coat. (k) PAINTING SYSTEM NO. 10 shall be applied to INTERIOR CONCRETE BLOCK SURFACES only when specified in the Special Conditions or Item X (Buildings). Painting System No. 10 shall be a polyvinyl acetate/latex or acrylic system consisting of: (1) Surface preparation, (See Paragraph 8.02(f)), and (2) Indurall PVA Block Filler P-1117 first field coat (one coat) applied at a rate to properly fill the voids and to produce a smooth surface and two field coats of Indurall Vinaflex Superior Interior Flat Finish applied at a rate of one gallon per 300 square feet per coat, or (3) Kop-Coat Concrete and Masonry Filler first field coat (one coat) applied at a rate to properly fill the voids and produce a smooth surface and two field coats of Kop-Coat 600 Interior-Exterior Acrylic Emulsion applied at a rate of one gallon per 300 square feet per coat, or (4) Tnemec Series 130 Masonry Filler first field coat (one coat) applied at a rate to fill the voids and to produce a smooth surface and two field coats of Tnemec Series 6 Tneme-Cryl applied at a rate of one gallon per 300 square feet per coat. (1) PAINTING SYSTEM NO. 11 shall be applied to EXTERIOR CONCRETE BLOCK SURFACES only when specified in the Special Conditions or Item X (Buildings). Painting System No. 11 shall be a urethane/acrylic latex, acrylic, or acrylic latex/acrylic system consisting of: (1) Surface preparation, (See Paragraph 8.02(f)`. and (2) Indurall Polyfill Block Filler first field coat gone coat) applied. at a rate to properly fill the voids and to produce a smooth surface and two field coats of Indurall Super Latex applied at a rate of one gallon per 300 square feet per coat, or (3) Kop-Coat Concrete and Masonrv 7i11er first field coat (one coat` applie? a- a rate to properlv fill the voids and produce a smoe-n surface and tw; ?:eid :oa-? of Kop-,oat 600 Interior-Exterior =crylic Emulsion applied at a rar., b 13.01 &= (a) The work covered by this item shall consist of the construction of one submersible grinder pumping station, complete, ready for operation. The station shall consist essentially of two submersible sewage grinder pumps, guide rails, access frames and covers, motor control center, hoist, and wet well structure. (b) Preparation and grading of site and excavation; concrete and steel reinforcement; valves and piping; access road; grassing and planting, miscellaneous metal work; and painting shall conform to the requirements of Items I, II, IV, V, VI, VII, and VIII, respectively, of these specifications. 13.02 General (a) Pumps and other equipment shall be new and unused, designed for the service intended, and shall be suitable for installation and efficient operation within the space and under the conditions shown on the plans and specified herein. (b) All structural steel work in mechanical equipment shall comply with the requirements of the American Institute of Steel Construction Specifications for the Design, Fabrication, and Erection of Structural Steel for Buildings. (c) The Contractor shall furnish the services of competent engineering representative of the manufacturer of the pumps to inspect their installation and supervise initial operation. Upon completion of such supervision, the manufacturer's representative shall provide the Engineer a signed certificate which states that the pumps have been checked, that they perform satisfactorily; and that they meet the requirements of the specifications. This certificate shall show the name of the pump manufacturer and the name of the company or firm by which the representative is employed. (d) The Contractor shall furnish to the Engineer six (6) copies of drawings of equipment to be furnished; foundation plans, number and position of all anchor bolts, manufacturer's specifications, parts lists, descriptive literature, complete electrical data and control diagrams, and operating and maintenance instructions. Six (6) copies of performance curves shall also be furnished for the pumping equipment, showing the condition point, shut-off head, the impeller diameter, the pump speed, and the horsepower. Descriptive literature and operating and maintenance instructions shall be fiirnished at the same time equipment drawings are fiirnished. This material shall be fiirnished in suitable binders. S-13-1 d 13.03 Submersible Sewage Grinder Pumps (a) Submersible sewage grinder pumps shall be capable of macerating raw, unscreened sewage. The discharge connection elbows shall be permanently installed in the wet well along with the discharge piping. The pumps shall be automatically connected to the discharge connection elbows when lowered into place and shall be easily removed for inspection and service. Installation and removal of pumps shall not require personnel to enter the wet well. Sealing of the pump units to discharge connections shall be accomplished by linear downward motion of the pumps. The pump, with its appurtenances and cable, shall be capable of continuous submergence in water to depths of 231 feet without leakage. (b) Each of the two submersible sewage grinder pumps shall have a capacity of 30 gpm at a TDH of 72 feet (Condition 1) and a capacity of 50 gpm at a TDH of 60 feet (Condition 2). The minimum efficiency at Condition 1 shall be 25%. The motor size shall be 3 HP. The maximum pump motor speed shall be 3,450 rpm. Motors shall be suitable for 460 vQh, 60 Hz, 3-phase current operation. (c) Pumps, motors, pump discharge connections, discharge elbows, guide rails, float switches with electrical cable, and pump guides shall be designed for Class 1, Groups C and D, Division 1, hazardous locations, as defined by the National Electrical Code and shall be so certified by an independent laboratory. (d) All bolts, machine screws, nuts, lockwashers, and other hardware used in the assembly of discharge elbows, guide rails, pump guides, and access frames and covers shall be of stainless steel. (e) Pumps shall be constructed of cast iron which complies with the requirements of ASTNI Specification A48, Class 30. All pump openings and passages, including impellers, shall be of adequate sizes to pass spheres at least one and one half inches (1.5") in diameter Impellers shall be the recessed, enclosed or open type having a minimum number of vanes and shall be of cast iron construction, dynamically balanced. Stainless steel impeller wearing rings with mating stainless steel case wearing rings shall be provided on the suction end of enclosed impellers. Shaft support rings shall be provided on the inboard side of open impellers. Impellers shall be mounted on the stainless steel motor shaft. An oil chamber and two mechanical-seals shall seal the motor from the pump liquid. Moisture detection probes shall be mounted in the oil chamber which are interlocked with the motor to shut down the pump and turn on a warning light on the motor control center when moisture is present in the oil chamber. Thermistors mounted in the bottom of the stator housing may be used instead of the moisture detection probes. Mechanical Seals shall consist of upper and lower seals. Upper seals shall have ceramic stationary faces and carbon rotating faces Nvith stainless steel springs. Lower seals shall have tungsten carbide stationary and rotating faces with stainless steel springs. Dischar(ge connections shall have contact surfaces of non-sparking materials. Dischargge elbow shall be of cast iron with integral bases for anchoring and supporting pumps and rioin_ Flanges shall 2ontonr, the requirements of.-\?,Sf lr' r N The metal contact surfaces shall be of non-sparking materials. Pump guides shall be of bronze. The entire pump units shall be designed for Class 1, Groups C and D, Division 1, hazardous locations, as defined by the National Electrical Code and shall be so certified by an independent laboratory, so that forced wet well ventilation and redundant cut-off switches are not required. A welded, hot-dipped galvanized steel rhl of adequate size shall be permanently attached to each pump. Provisions shall be made for attaching the upper end of each chain to the wet well access frame and cover. (0 Submersible pump motors shall be designed for Class 1, Groups C and D, Division 1, hazardous locations as defined by the National Electric Code and shall be so certified by an independent laboratory. Motors shall be explosion proof, squirrel cage induction type housed in an air-filled cast iron watertight enclosure. The enclosure shall be sealed by "0"-rings and shall have rabbet joints with a large overlap. Cable leads shall be epoxy sealed. The motor shaft extension shall be stainless steel, impervious to the liquid and waste materials being pumped. All external hardware including motor nameplates shall be made of stainless steel. Motors shall be NEMA Design B; insulation shall be Special Class F rated for continuous duty in 40°C liquids; shall have a 1.15 service factor; shall be equipped with winding thermostats; shall be capable of operating for 15 minutes in air at nameplate horsepower, and shall be capable of 15 starts per hour. The pumps shall be furnished with power and control cords of sufficient length to connect to the motor control center. The pump motors shall be sized so that they will not be overloaded at their rated capacity at any point on the pump performance curve. (g) Submersible sewage grinder shall be manufactured by the F.E. Meyers Co., Hydro- O-NIatic Pump Division, or equal. 13.04 Guide Rails (a) Guide rails shall be of hot-dipped galvanized steel which shall be attached to the access frame and cover by brackets. 1 1.05 Access Frame and Cover (a) The wet well access frame and covers shall be single door hatches of all aluminum constriction. They shall be of the sizes shown on the plans or selected by the pump manufacturer. Covers shall be of checkered plate. Stainless steel torsion springs shall hold doors in open position. Entrance shall be by a removable key A handle on the inside shall permit inside door opening. ! ? ?)r blot or ntroI renter ?a) The motor control center shall control the operation of the two pumps. The motor control center shall contain starters for each pump, pump alternation and level sensing circuits, alarm circuits, and control devices as specified and as required. The motor control center shall also cwitain a l ? anup_ 120 volt duplex receptacle with a capacity of at least SIVI volt amperes. (b) Each pump starter shall be a combination magnetic full voltage circuit breaker type with magnetic trip circuit breaker and thermal overload elements in each phase. The circuit breaker and overload elements shall be selected and set for the nameplate characteristics of the motor furnished and not "typical" values. The starter shall be UL listed for use on a system with available fault current of at least 22,000 amperes. (c) Float switches in the wet well shall be connected to intrinsically safe relays. Relays shall be provided for pump stop, pump start, and high water alarm points. Controls shall provide for automatic alternation of the pumps after each pump run cycle. Controls shall only allow one pump to run at a time. Failure of the duty pump shall cause the standby pump to run. (d) The alarm circuits shall activate an audible alarm signal and a flashing alarm light on top of the motor control center. Silence and test pushbuttons shall be provided for the alarm circuits. Alarm shall be activated by the failure of either pump, moisture in pump oil chamber, pump motor over temperature, or high water. Circuits as recommended by the submersible motor manufacturer shall be used to sense moisture in the oil chamber. Detection of moisture or motor over temperature shall cause the motor to be taken out of service which shall be restarted only by manual means. (e) Control circuits shall operate at 120 volts from a fused control transformer. Devices for each motor shall include a hand-off-automatic selector switch, an elapsed time meter, and a current transformer driven ammeter. A phase failure/phase reversal relay shall be furnished to remove both pumps from service. The relay shall operate if voltage on any phase drops below 85% of nominal voltage. Drop out point shall be adjustable over a range of at least 80 to 95% of nominal. Pump operation which is interrupted because of power failure shall re-start automatically upon power restoration. Pilot lights shall be furnished to indicate phase failure, high water, and moisture seal failure. f) The motor control center shall be assembled in a NEMA 4 enclosure suitable for pole mounting Enclosure shall feature a hinged outer door with key operated cylinder lock and a hinged inner door containing all control devices. All breakers, overload resets, etc. shall be operable ,vithout opening the inner door. All control devices shall be identified with an engraved laminated nameplate permanently attached. Internal wiring shall be permanently identified with wire and terminal numbers and grouped and tied to present a neat appearance. The complete motor control center shall be suitable for use on the voltage shown for the pump motors elsewhere in these specifications and shall comply with all requirements of the National Electrical Code or any state or local ordinances. The enclosure shall be painted in the shop of its manufacturer. `,- 1 3-4 r 1? . A 13.07 Float Switches (a) Three float switches shall be provided for the station. They shall be mercury encapsulated type and sealed within a polyurethane ball. A weight shall be provided for each float switch. A single stainless steel bracket shall hold the three float switches. Float switches and electrical cable shall be certified by an independent laboratory for Class 1, Groups C and D, Division 1, hazardous locations as defined by the National Electric Code. Float switches shall be furnished with sufficient cord to connect to the motor control center. 13.08 Electrical Wir= (a) The electrical wiring shall consist of a service pole (or service mounting frame for underground power supply) , service entrance, main breaker, power wiring to pump control panel, power and control wiring to the pumps, grounding system and metering provisions as required by the electric utility. All wiring shall comply with the requirements of the National Electrical Code, any state or local codes or ordinances, and the electric utility company. All materials shall be listed by Underwriters Laboratories and shall be new and delivered to the job in its original cartons. All conduits shall be rigid galvanized steel, minimum, 3/4" trade size, meeting UL and ANSI standards. Conduit fittings shall be plated malleable iron or cast aluminum. All power and control conductors shall be Class B stranded copper. Power conductors shall be minimum number 12 AWG Type RHH-RHW-USE meeting ICEA Standard S-68-516 or 5-66-524. Control conductors shall be minimum No. 14 AWG Type THHN. Ground conductors shall be medium soft drawn, stranded copper meeting ASTM Standard B-8. Connectors and terminals shall he olderless compression or pressure type cast connectors. Below grade ground connections shall be exothermically welded. All wirinu shall be run in conduit except pump power and control cords within the wet well. (b) The service pole, if required, shall be creosoted pine, minimum class 4, with at least 20'/'0' of its length set in earth and firmly tamped. Height, location, and setting depth shall be as required by the electric utility. For underground power supplies, salt treated 4x4" shall be used to construct a rectangular frame for panel mounting. (cl The main breaker shall be an enclosed circuit thermal-maenetic breaker, 3 pole 600,volt labeled as suitable for service equipment. The service shall be protected with a three pole secondary lightning arrestor connected directly to the grounding system (d) All wiring methods and materials within the wet well shall comply with code requirements for Class I, Groups C and D, Division I, hazardous locations. Pump power and control cords shall be nun from the wet well to the pump control panel underground in conduit. Conduit and fittings shall be coated with a coal tar protective svstem to four inches above finished grade onduit shall he sealed around the cord inside :he ,?et well in such a manner that the cord and ;e;: i. ?)e removed t'rom the cond!.ii, iystem when ,4te pump must he ren,,,,,ved for repair. S-1 3 ? 11 (e) The grounding system shall consist of bare copper conductors, minimum No. 2 AWG bonding together the wet well reinforcing steel, the pump rails, metallic piping, the utility company neutral conductor, and a driven 3/4" x 10' copper clad ground rod at the service pole. Grounding bushings shall be used at all conduit terminations in enclosures to ensure ground continuity. (0 The Contractor shall coordinate the installation with the electric utility. The Contractor shall furnish and/or install metering provisions as required by the utility, verify service voltage, and include in his bid any charges from the utility for providing service to the station. 13.09 Hoist (a) A winch type removable hoist shall be provided to service both pumps with appropriate mounting brackets and post sleeves in top slab. The hoist shall be a cable type having a fabricated steel support frame. It shall have a minimum capacity of 1,500 pounds at 3 feet from hoist support and 500 lbs at 8 feet. The winch shall have a brake (clutch type) that will hold the rated load without allowing the crank to reverse rapidly and injure the operator when raising or lowering the pump. The winch shall be geared at a ratio between 20:1 and 15:1, load raised vs. force applied to crank handle. The cable end shall be fitted with a grab hook to properly connect to the lifting chain which is attached to the pump-motor combination. A separate chain shall be supplied to allow temporary support of the pump while the cable is unhooked from the pump chain and be attached lower on the chain to raise the pump in incremental lifts. The hoist shall be capable of 270° rotation with a full load. The hoist shall be mounted to allow 90° clockwise and 180° counter clockwise rotation along center line axis of top slab. The hoist arm shall be long enouL,h to allow vertical plumb placement of a pump on a truck positioned next to the top slab with set down area centered three feet off edge of slab. 13.10 Wet Well Structure (a) The wet well structure shall consist of a precast concrete manhole and poured concrete of the type and size shown on the plans. The precast manhole sections shall conform to the applicable requirements of Item IV of these specifications. 13.1 1 Installation and Erection (a) Pumps and other equipment shall be erected and installed by competent, skilled mechanics at the exact positions and elevations shown on the plans. (b) The Contractor shall furnish all necessary oil and grease for the operation of the equipment during the initial trial operation Anchor bolts shall be type 304 stainless stee,, accurately placed in the concrete roundatnons in their exact position and elevation by the use of template;, and all anchor bolt settins:s shall be carehilly checked before concrete for the foundation is placed. 8- 13-n n r ? . J6 (d) All equipment and connecting piping shall be installed in such manner that no load from the piping will be carried by the pumps. (e) The Contractor shall properly grout each piece of equipment after it has been carefully aligned and leveled with steel wedges. The grout shall be poured so as to completely fill the space between the bottom of the base of the equipment and the top of the foundation. Grout shall be a non-shrinking type. (f) After erection, all equipment shall be tested in a manner satisfactory to the Engineer and any defects or deficiencies found shall be corrected by the Contractor. 13,12 Payment (a) Payment for the Submersible Sewage Pumping Station, excavation, concrete, and steel reinforcement, valves and piping, access road, grassing and planting, miscellaneous metals, and painting completely constructed under these specifications by the Contractor and accepted by the Engineer shall be made at the lump sum contract price listed under Item XII of the Proposal. This amount, so paid, shall cover the cost of furnishing all equipment and materials, tools, and plant; and performing all labor necessary for, or incidental to the construction of the Submersible Sewage Grinder Pumping Station as specified herein. 8-13-7 I-A l_E? I F& IMI(-;I IT September 21, 1999 / Mr. John R. Dornc y PAYMENT ??`? p Water Quality Planning 1`ECEIvEg &6N ? Division of Water Quality NC Dept. of Environment and Natural Resources /99 4401 Reedy Creek Road k'q k'ET?q , 9 Raleigh, NC 27607q U ?orySFp?p CT/Jnr RE: RE-SUBMITTAL Pre-Construction Notification Application Mountain Area Child and Family ('enter Pump Station and Force Main Buncombe County, NC TBI No. 5903-9901 'vsi A Dear Mr. Dorney: Enclosed is A ('HECK FOR $200.00 and seven copies of the completed submittal package to the U.S. Army Corps of Engineers including the cover letter to David Baker, dated July 27, 1999,permit application form, the Technical Specifications, 8.5" by I I " plan views of the proposed stream crossing for the above project. The NCDENR non-discharge permit application was sent to Mr. Kim Colson on July 27, 1999. If you should have any questions concerning the project or this application, please contact me at (910) 763-5350. Sincerely 41 William L. Morris, Jr W LM/bm cc: Chris Rogers file: F:\Admin\5903\JDORNEY,WQP92 Ldoc I.NGINFI:RING & PLANNING CON SUTAAN IS THE COI ION F.XCIIANGE • 321 N. FRONT SFRLFi' • WILMINGTON, NC 28401 • 910.763.5350 - FAX 910.762.6281 CIIARLOTi'L:, NORI'II CAROLINA • WILMINGTON. NOR[ II CAROLINA- RICIIMOND, VIRGINIA I n.I ,IWIM' &, I?RIGI I V August 4, 1999 Water Quality Planning Division of'Water Quality NC Dept. of'F,nvironment and Natural Resources 4401 Reedy Creek Road Raleigh, NC 27607 RE: Pre-Construction Notification Application Submittal Mountain Area Child and Family Center Pump Station and Force Main Buncombe County, NC 'FBI No. 5903-9901 Dear Sirs: NDS 6.1"JiP " AH1Y SECT'"' Enclosed is seven copies of the completed submittal package to the U.S. Army Corps of' Engineers including the cover letter to David Baker, dated July 27, 1999,pennit application form, the Technical Specifications, 8.5" by I I " plan views of'the proposed stream crossing for the above project. The NCDENR non-discharge pen-nit application was sent to Mr. Kim Colson on July 27, 1999. If you should have any questions concerning the project or this application, please contact me at (910) 763-5350. Sincerely, William L. Morris, Jr., P.l',. , WI,M/bm cc: Chris Rogers file: F:\Admin\5903\WQP804.doc ENGINI.I.RING h I'IANN ING CONSUI:LAN I'S I I ll: CO"I ]ON I.XCI IAN(;l - :321 N FRON I SIR[ 1:1 • WII-MING LON. NC. 28401 ? 910.763.5350 • I?AX 9107620281 CIIARLOI?1Ii. NORI II CAROLINA • WI IMINGTON, NORIII CAROI INA RRAIMOND. VIRGINIA