December 16, 2019
SUBJECT: Compliance Inspection Report
Morehead City WWTP
NPDES WW Permit No. NCO026611
Carteret County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Morehead City WWTP
on 12/05/2019. This inspection was conducted to verify that the facility is operating in compliance with
the conditions and limitations specified in NPDES WW Permit No. NC0026611. The findings and
comments noted during this inspection are provided in the enclosed copy of the inspection report
entitled "Compliance Inspection Report". There were no significant issues or findings noted during the
inspection and therefore, a response to this inspection report is not required.
If you should have any questions, please do not hesitate to contact Helen Perez with the Water
Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at
helen.perez@ncdenr.gov.
Sincerely,
E-T
DocuSigned by:
oµ 'TAU-M) �cOA, for
7F141E73B6F3456...
Morelia Sanchez -King, Regional Supervisor
Water Quality Regional Operations Section
Wilmington Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS
Cc: Chad Sutton — electronic copy
Uploaded to Laserfiche
NorthC.aroSnaDepartrcantoftnvironmeata3Qaadrty I DWsion of Water Resou roes
r, Wilniiagbon Reg •3ca-Off w 1 127 CA rd'inslD ivefxtension I VAIrnington, North Caro --ra23405
�'T._..... 910-796-7215
DocuSign Envelope ID: E001B10C-C3E8-47A8-AE90-9671EB9E8545
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN I 2 IF I 3 I NCO026611 111 12 I 19/12/05 I17 18 I S i 19 i G i 201 I
211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating 131 QA ---------------------- Reserved -------------------
671
70Id I 71 I I 72 I r, I 73I I I74 751 I I I I I I I80
I —I I� I I i
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES oermit Number)
10:15AM 19/12/05
13/04/01
Morehead City WWTP
1000 Treatment Plant Rd
Exit Time/Date
Permit Expiration Date
Morehead City NC 28557
12:OOPM 19/12/05
17/07/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
William Chad Sutton//252-726-6237 /
William Chad Sutton/ORC/252-726-6237/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Daniel K Williams,706 Arendell St Morehead City NC 285574234/Public Utilities
Director/252-726-6848/2527262267 Yes
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
DOCO$1g"ea �'y- DWR/WIRO WQ/910-796-7387/
Helen I PerezE
12/16/2019
1 D645B4A39694BE...
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
DocuSigned by: 12/18/2019
Tom TharringtfWQ/
Toµ �1
oWR/WIRO
"- 71`141 E731361`3456...
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
DocuSign Envelope ID: E001B10C-C3E8-47A8-AE90-9671EB9E8545
NPDES yr/mo/day Inspection Type (Cont.)
NCO026611 I11 121 19/12/05 117 18 ICI
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
A routine compliance inspection of the Morehead City WWTP was conducted on December 5, 2019.
The purpose of the evaluation was to verify that the facility is operating in compliance with the
conditions and limitations specified in Permit NC0026611. Chad Sutton, facility ORC, was present
during the inspection.
The facility is well maintained and records were organized and complete. A thorough check and
maintenance of the entire plant to include oil, belts, grease and filters is scheduled twice a year, and
the most recent schedule was completed in October. The grit and classifier system has not been in
operation for approximately five months. The City is in the process of planning the replacement of the
whole system. Also planned are repairs and part replacements to the two clarifers.
A review of files for the last two years indicated one violation issued, a NOD in June 2018 for a weekly
TSS limit violation. The Morehead City WWTP permit expired on July 31, 2017. The permit renewal is
currently in draft form.
The facility is compliant with NPDES permit NC0026611. Please review the comment sections of the
inspection report for more details.
Page#
DocuSign Envelope ID: E001B10C-C3E8-47A8-AE90-9671EB9E8545
Permit: NCO026611 Owner - Facility: Morehead City WWTP
Inspection Date: 12/05/2019 Inspection Type: Compliance Evaluation
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
0
❑
❑
❑
application?
Is the facility as described in the permit?
0
❑
❑
❑
# Are there any special conditions for the permit?
0
❑
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the inspector granted access to all areas for inspection?
0
❑
❑
❑
Comment: The Dermit exDired on July 31. 2017. and the new Dermit is currently in draft form. SDecial
conditions include the requirement of notification of release of any partially treated or
untreated wastewater to the Marine Fisheries, Shellfish Sanitation and Recreational Water
Quality Section. Also, there is a requirement to notify the Wilmington Regional Office if the
UV disinfection system fails.
Record Keeping
Yes No NA NE
Are records kept and maintained as required by the permit?
0
❑
❑
❑
Is all required information readily available, complete and current?
0
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
0
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
0
❑
❑
❑
Is the chain -of -custody complete?
0
❑
❑
❑
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator
❑
❑
❑
on each shift?
Is the ORC visitation log available and current?
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
❑
❑
❑
Is a copy of the current NPDES permit available on site?
0
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
❑
❑
❑
Comment: Operation/maintenance log was detailed and complete.
Page# 3
DocuSign Envelope ID: E001B10C-C3E8-47A8-AE90-9671EB9E8545
Permit: NCO026611 Owner - Facility: Morehead City WWTP
Inspection Date: 12/05/2019 Inspection Type: Compliance Evaluation
Laboratory
Yes No NA NE
Are field parameters performed by certified personnel or laboratory?
0
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
0
❑
❑
❑
# Is the facility using a contract lab?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
❑
❑
❑
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
❑
❑
❑
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
❑
❑
❑
Comment: The majority of the reportable parameters are analyzed by the facility lab,certification #19.
The remaining parameters are analyzed by the contract lab, Envirochem, certification # 94.
Bench sheets and calibration sheets for the Hach DO meter and the Thermo Scientific
Orion pH meter were complete. Standards for pH calibration were within expiration dates.
Flow Measurement - Influent
Yes No NA NE
# Is flow meter used for reporting?
❑
0
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
0
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
❑
Comment: The flow meter was calibrated on 10-30-18 by Chadwick Instruments. This years calibration
is scheduled for 12-16-19 and the ORC will send the records when it is completed.
Flow Measurement - Effluent
Yes No NA NE
# Is flow meter used for reporting?
0
❑
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
0
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
❑
Comment: The flow meter was calibrated on 10-30-18 by Chadwick Instruments. This vears calibration
is scheduled for 12-16-19 and the ORC will send the records when it is completed.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The oxidation ditch system is monitored for DO, temp, PH, mixed liquor solids and a
microscopic inspecton daily. Settleable solids are monitored twice a week.
Bar Screens
Type of bar screen
Page# 4
DocuSign Envelope ID: E001B10C-C3E8-47A8-AE90-9671EB9E8545
Permit: NCO026611 Owner - Facility:
Morehead City WWTP
Inspection Date: 12/05/2019 Inspection Type:
Compliance Evaluation
Bar Screens
Yes No NA NE
a.Manual
❑
b.Mechanical
Are the bars adequately screening debris?
❑
❑
❑
Is the screen free of excessive debris?
❑
❑
❑
Is disposal of screening in compliance?
0
❑
❑
❑
Is the unit in good condition?
❑
❑
❑
Comment: There are three barscreen units within the collection system at
pump stations #9, #10 and
#18A. Pump station #10 is located outside of the fenced WWTP. Screening debris is
disposed of at the landfill.
Grit Removal
Type of grit removal
Yes No NA NE
a.Manual
❑
b.Mechanical
Is the grit free of excessive organic matter?
❑
❑
❑
Is the grit free of excessive odor?
❑
❑
❑
# Is disposal of grit in compliance?
❑
❑
❑
Comment: The Lakeside Raptor grit removal and classifier system has not been in operation for
approximately 5 months due to a broken pipe.
Plans are in place to replace the whole unit in
the near future.
Influent Sampling
Yes No NA NE
# Is composite sampling flow proportional?
0
❑
❑
❑
Is sample collected above side streams?
0
❑
❑
❑
Is proper volume collected?
❑
❑
❑
Is the tubing clean?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
Is sampling performed according to the permit?
0
❑
❑
❑
Comment: The composite sampler was 4°C and the tubing was clean. Staff changes the tubing two
times a month in the winter and three times a month in the summer.
Oxidation Ditches Yes No NA NE
Are the aerators operational? 0 ❑ ❑ ❑
Are the aerators free of excessive solids build up? 0 ❑ ❑ ❑
Page# 5
DocuSign Envelope ID: E001B10C-C3E8-47A8-AE90-9671EB9E8545
Permit: NCO026611 Owner - Facility:
Inspection Date: 12/05/2019 Inspection Type:
Morehead City WWTP
Compliance Evaluation
Oxidation Ditches
Yes No NA NE
# Is the foam the proper color for the treatment process?
0
❑
❑
❑
Does the foam cover less than 25% of the basin's surface?
0
❑
❑
❑
Is the DO level acceptable?
0
❑
❑
❑
Are settleometer results acceptable (> 30 minutes)?
❑
❑
❑
Is the DO level acceptable?(1.0 to 3.0 mg/1)
0
❑
❑
❑
Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes)
❑
❑
❑
Comment: Influent and RAS mix toaether as it enters the three anerobic reactors. There are two mixers
in each reactor. Wastewater then flows to the first oxidation ditch which is in anoxic mode. It
then flows to the second oxidation ditch in oxic mode. DO levels in ditch one was 0.06 mq/I
and 1.68 mg/I in ditch two during the inspection.
Nutrient Removal Yes No NA NE
# Is total nitrogen removal required? 0 ❑ ❑ ❑
# Is total phosphorous removal required? 0 ❑ ❑ ❑
Type Biological
# Is chemical feed required to sustain process? N ❑ ❑ ❑
Is nutrient removal process operating properly? 0 ❑ ❑ ❑
Comment: The permit has a Total Nitrogen limit of 41,856 Ibs/year and a Total Phosphorus limit of
7,610 Ibs/year. Staff keeps a <2 mq/I monthly average for Total Phosphorus and a <9 mq/1
monthly average for Total Nitrogen to stay within the yearly permit limit. Alum is fed in
approximately late May through October to aid in phosphorus removal.
Secondary Clarifier
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
0
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
0
❑
❑
❑
Are weirs level?
0
❑
❑
❑
Is the site free of weir blockage?
0
❑
❑
❑
Is the site free of evidence of short-circuiting?
0
❑
❑
❑
Is scum removal adequate?
0
❑
❑
❑
Is the site free of excessive floating sludge?
0
❑
❑
❑
Is the drive unit operational?
0
❑
❑
❑
Is the return rate acceptable (low turbulence)?
0
❑
❑
❑
Is the overflow clear of excessive solids/pin floc?
0
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
❑
❑
❑
Page# 6
DocuSign Envelope ID: E001B10C-C3E8-47A8-AE90-9671EB9E8545
Permit: NC0026611 Owner - Facility: Morehead City WWTP
Inspection Date: 12/05/2019 Inspection Type: Compliance Evaluation
Secondary Clarifier Yes No NA NE
Comment: Weirs are cleaned two times a month. The sludge blanket is checked twice a day and level
is kept around two feet. Plans are in place to repair and/or replace parts on the clarifiers in
the near future due to age.
Pumps-RAS-WAS
Yes No NA NE
Are pumps in place?
0
❑
❑
❑
Are pumps operational?
0
❑
❑
❑
Are there adequate spare parts and supplies on site?
0
❑
❑
❑
Comment: No comment.
Chemical Feed
Yes No NA NE
Is containment adequate?
0
❑
❑
❑
Is storage adequate?
0
❑
❑
❑
Are backup pumps available?
❑
❑
❑
Is the site free of excessive leaking?
0
❑
❑
❑
Comment: No comment.
Filtration (High Rate Tertiary)
Yes No NA NE
Type of operation:
Down flow
Is the filter media present?
❑
❑
❑
Is the filter surface free of clogging?
❑
❑
❑
Is the filter free of growth?
❑
❑
❑
Is the air scour operational?
❑
❑
❑
Is the scouring acceptable?
❑ ❑
❑
Is the clear well free of excessive solids and filter media?
❑
❑
❑
Comment: Tertiary filtration consists of dual traveling bridge sand filters. The filters are backwashed
automatically every four hours or more often due to activation of a high float switch.
Disinfection - UV
Are extra UV bulbs available on site?
Are UV bulbs clean?
Is UV intensity adequate?
Is transmittance at or above designed level?
Is there a backup system on site?
Is effluent clear and free of solids?
Yes No NA NE
❑ ❑ ❑ ■
❑ ❑ ❑ ■
❑ ❑ ❑ ■
❑ ❑ ❑ ■
❑ ❑ ❑ ■
■ ❑ ❑ ❑
Page# 7
DocuSign Envelope ID: E001B10C-C3E8-47A8-AE90-9671EB9E8545
Permit: NCO026611 Owner - Facility: Morehead City WWTP
Inspection Date: 12/05/2019 Inspection Type: Compliance Evaluation
Disinfection - UV
Yes No NA NE
Comment: One UV bank of the three banks in series was in operation during the inspection. A post
aeration tank is located before the UV system. The tank is covered to control algae growth
and is also cleaned twice a year.
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Comment: Tubinq was clean and sampler temperature was 4.5° C.
Aerobic Digester
Is the capacity adequate?
Is the mixing adequate?
Is the site free of excessive foaming in the tank?
# Is the odor acceptable?
# Is tankage available for properly waste sludge?
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑ ■
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑ ■
❑ ❑ ❑ ■
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Comment: One of the two digesters was cleaned in 2017 to remove grit and debris and improve
digester performance. The City plans to cleaned the second digester when the budget
allows.
Solids Handling Equipment
Is the equipment operational?
Is the chemical feed equipment operational?
Is storage adequate?
Is the site free of high level of solids in filtrate from filter presses or vacuum filters?
Is the site free of sludge buildup on belts and/or rollers of filter press?
Is the site free of excessive moisture in belt filter press sludge cake?
The facility has an approved sludge management plan?
Yes No NA NE
■ ❑ ❑ ❑
❑ ❑ ❑ ■
• ❑ ❑ ❑
• ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Page# 8
DocuSign Envelope ID: E001B10C-C3E8-47A8-AE90-9671EB9E8545
Permit: NC0026611 Owner - Facility: Morehead City WWTP
Inspection Date: 12/05/2019 Inspection Type: Compliance Evaluation
Solids Handling Equipment
Yes No NA NE
Comment: The facility produces Class A residuals the majority of the time. The sludge press and dryer
system is operated every 5-6 weeks. It takes 5-6 days to press all the material. When Class
B residuals are made, they are removed and disposed of by Lewis Farms. Presses were
not in operation at time of inspection.
Standby Power
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
Is the generator fuel level monitored?
Yes No NA NE
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ❑ ■
■ ❑ ❑ ❑
❑ ❑ ❑ ■
❑ ❑ ❑ ■
Comment: The facility has two generators, one for the laboratory building and the other for the rest of
the wastewater plant. The generators are tested weekly under load and maintained by
Morehead City staff.
Page# 9