HomeMy WebLinkAboutNC0020443_Inspection_20191216ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director Rhett B White Town of Columbia PO Box 361 Columbia, NC 27925-0361 NORTH CAROLINA EsvkVRMe^W Quattry December 16, 2019 SUBJECT: Compliance Inspection Report Columbia WWTP NPDES WW Permit No. NCO020443 Tyrrell County Dear Mr. White: The North Carolina Division of Water Resources conducted an inspection of the Columbia WWTP on 10/16/2019. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0020443. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact me with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481 or via email at robert.e.bullock@ncdenr.gov. Sincerely, Robbie Bullock, Environmental Specialist II Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: Laserfiche / R EW North Cotorgton R g onsDopaO fi of E43 Wammta'.'.�ua+t}• I O�vsan of Wtter RNaouroes � Wesh n;uin Red or -.a �Hae 1943 Wash I Wash++gtan, North Caro ra 278139 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO020443 I11 12 19/10/16 17 18 1 S T 191 S 1 201 1 211111111111111111111111111111111 111111111 11 16 Inspection Work Days Facility Self -Monitoring Evaluation Rating 61 CIA ----- --------- --Reserved----------- 67 70LJ 71itJI 72 (—N 73174 751 I I I I 80 Section B: FacilityData Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES Permit Number) 10:30AM 19/10/16 17/12/01 Columbia WWTP Exit Time/Date Permit Expiration Date Green St Columbia NC 27925 12:OOPM 19/10/16 22/11/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Tim Farrell Oliver/ORC/252-796-2781/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Rhett B White,PO Box 361 Columbia NC 279250361/Town Manager/252-796-2781/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program 0 Sludge Handling Disposal Facility Site Review Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Robert E Bullock DWR/Division of Water Quality/252-948-3924/ // % -. 7 "i- Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type (Cont.) 31 NCO020443 I11 121 19/10/16 I17 18I Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The review period for this inspection was from October 2016 through August 2019. On the day of inspection solids appeared to be high in the Oxidation ditch. MLSS sample results from the Oxidation ditch were: 6-4-2019 6,767 mg/I 6-18-2019 7,100 mg/1 8-13-2019 8,700 mg/1 8-20-2019 12,300 mg/1 8-27-2019 8,367 mg/1 The sludge blankets in the clarifiers were measured during the inspection. The sludge blanket levels were: #1 8' sludge with 4' clear #2 5' sludge with 7' clear #3 5' sludge with 7' clear #4 10' sludge with 2' clear The MLSS under aeration and the sludge levels in the clarifiers were excessive. The facility needs to better manage the sludge in the WWTP. Effluent samples were taken during the inspection. The sampling results were within permitted limits and are as follows: Ph 7.32 Dissolved Oxygen 8.89 mg/1 Temperature 21.47 degrees C BOD 2.0 mg/I Total Suspended Solids 12 mg/1 Ammonia 0.02 mg/1 Nitrate -Nitrite 13 mg/1 TKN 1.2 mg/I Total Phosphorus 1.4 mg/1 Enterococci 138 colonies/100ml Page# Permit: NCO020443 Owner - Facility: Columbia WWTP Inspection Date: 10/16/2019 Inspection Type: Compliance Sampling Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (if the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ M ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? 0 ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: The current permit is set to expire on November 30, 2022. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? M ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? M ❑ ❑ ❑ Dates, times and location of sampling ❑ Name of individual performing the sampling ❑ Results of analysis and calibration ❑ Dates of analysis ❑ Name of person performing analyses ❑ Transported COCs ❑ Are DMRS complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? M ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ M ❑ on each shift? Is the ORC visitation log available and current? 0 ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? 0 ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? 0 ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Page# 3 Permit: NCO020443 Inspection Date: 10116/2019 Record Keeping - Facility has copy of previous year's Annual Report on file for review? Owner - Facility: Columbia WWTP Inspection Type: Compliance Sampling Comment: The June 2019 DMR was spot checked for accuracy with no discrepancies found. Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE ■ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Comment: The Town of Columbia is field parameter certified for PH, Temperature, Chlorine and Dissolved Oxygen. All other parameters are sent to Environment 1 for analysis. Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: On the day of inspection the sampler temperature was 3 degrees. Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Yes No NA NE ■ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 4 Permit: NCO020443 Owner - Facility: Columbia WWTP Inspection Date: 10/16/2019 Inspection Type: Compliance Sampling Grit Removal Yes No NA NE Type of grit removal a.Manual ❑ b.Mechanical Is the grit free of excessive organic matter? 0 ❑ ❑ ❑ Is the grit free of excessive odor? 0 ❑ ❑ ❑ # Is disposal of grit in compliance? N ❑ ❑ ❑ Comment: Oxidation Ditches Yes No NA NE Are the aerators operational? N ❑ ❑ ❑ Are the aerators free of excessive solids build up? 0 ❑ ❑ ❑ # Is the foam the proper color for the treatment process? ❑ M ❑ ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? 0 ❑ ❑ ❑ Are settleometer results acceptable (> 30 minutes)? ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ ❑ 0 Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) ❑ ❑ ❑ 0 Comment: On the day of inspection the solids appeared to be high in the Oxidation ditch. MLSS sample results from the Oxidation ditch were: 6-4-2019 6.767 mg/I 6-18-2019 7,100 mg/I 8-13-2019 8,700 mg/I 8-20-2019 12,300 mg/I 8-27-2019 8,367 mg/I The facility has an excess of sludge in WWTP. Solids need to be wasted and land applied Pumps-RAS-WAS Yes No NA NE Are pumps in place? 0 ❑ ❑ ❑ Are pumps operational? 0 ❑ ❑ ❑ Are there adequate spare parts and supplies on site? ❑ ❑ ❑ Comment: Aerobic Digester Is the capacity adequate? Yes No NA NE ■ ❑ ❑ ❑ Page# 5 Permit: NCO020443 Inspection Date: 10/16/2019 Owner - Facility: Columbia WWTP Inspection Type: Compliance Sampling Aerobic Digester Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Comment: On the day of inspection one digester was approximately 80% full Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/. of the sidewall depth) Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ■ ❑ ❑ Comment: The sludge blankets in the clarifiers were measured during the inspection. The sludge blanket levels were: #1 8' sludge with 4' clear #2 5' sludge with 7' clear #3 5' sludge with 7' clear #4 10' sludge with 2' clear The facility needs to better manage the sludge in the WWTP. Disinfection-Liguid Is there adequate reserve supply of disinfectant? (Sodium Hypochlorite) Is pump feed system operational? Is bulk storage tank containment area adequate? (free of leaks/open drains) Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment: Yes No NA NE ■ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 6 Permit: NCO020443 Owner - Facility: Columbia WwTP Inspection Date: 10/16/2019 Inspection Type: Compliance Sampling Disinfection -Liquid Yes No NA NE De -chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? 0 ❑ ❑ ❑ Is storage appropriate for cylinders? ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? 0 ❑ ❑ ❑ Comment: Are the tablets the proper size and type? ❑ ❑0 ❑ Are tablet de -chlorinators operational? ❑ ❑ 0 ❑ Number of tubes in use? Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? M ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ M ❑ Comment: The effluent flow meter was calibrated on 12-18-18 Effluent Sampling Yes No NA NE Is composite sampling flow proportional? M ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type M ❑ ❑ ❑ representative)? Comment: On the day of inspection no thermometer was in the refrigerator. A thermometer needs to be maintained in the refrigerator to ensue that sample storage is below 6 degrees C Page# 7 AC68817 North Carolina Division of Water Resources Water Sciences Section Laboratory Results Loc. Descr.: County: Region: River Basin Emergency COC Yes/No Columbia WWTP Effluent MIMH Collector: R BULLOCK VisitlD Washington Report To WARD Location ID: WARO NLC PAS Collect Date: 10/1612019 Priority COMPLIANCE Collect Time: 11_69 Sample Matrix: WASTEWATER Sample Depth Loc. Type: Effluent Sample ID: AC68817 PO Number # Date Received: 10/17/2019 Time Received: 08:20 Labworks LoginlD TASCENZ01 Delivery Method NC Courier Final Report Date: 12/16/19 Report Print Date: 12/16/2019 Final Report If this report is labeled preliminary report, the results have not been validated. Do not use for Regulatory purposes. Result/ Method Analysis CAS # Analyte Name PQL ualifier Units Reference Date Validated by LAB Sample temperature at receipt by lab Sample temperature at receipt by lab 1.1 °C 10/17/19 MSINIFT MIC BOD, 5-Day in liquid BOD, 5-Day in liquid 2.0 2.0 G5 mg/L SM 5210 B-2001 10/17/19 ESTAFFORD1 NUT NH3 as N in liquid NH3 as N in liquid 0.02 0.02 mg/L as N EPA 350.1 REV 2 11/1/19 MIBRAHIM1 NO2+NO3 as N in liquid NO2+NO3 as N in liquid 0.02 13 mg/Las N EPA353.2 REV 11/1/19 MIBRAHIM1 Phosphorus —total as P in liquid Phosphorus —total as P in liquid 0.02 1.4 mg/LasP EPA365.1 REV 1116/19 MIBRAHIM1 Total Kjeldahl N as N in liquid Total Kjeldahl N as N in liquid 0.2 1.2 mg/L as N EPA 351.2 REV 2 11l7/19 MIBRAHIM1 WET Residue —Suspended in liquid Residue —Suspended in liquid 12 12 U mg/L SM 2540 D-1997 10/21/19 AWILLIAMS WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 7333908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 1 of 3 NC D Wk Laboratory Section q(�sufts/Sampk Comments/QuaC�r Definitions Sample ID: AC68817 Result/ Method Analysis vrw it �"s Y. wan is BOD-G5-Estimated-GGA standard recovery was < 198+/-30.5mg/I Qualifier Units Reference Date Validated by Sample Comments NCDEQ-WSS-Chemistry Lab Data Qualifiers Al The reported value is an average, where at least one result is qualified with a "U". The PQL is used for the qualified result(S) to call B1 Coliform-Countable membranes with less than 20 colonies. Reported value is estimated or is a total of the counts on all filters repor B2 Coliform-Counts from all filters were zero. The value reported is based on the number of colonies per 100 ml that would have been B3 Coliform-Countable membranes with more than 60 or 80 colonies. The value reported is calculated using the count from the smalle: B4 Coliform-Filters have counts of both >60 or 80 and <20. Reported value is estimated or is a total of the counts on all filters reported B5 Coliform-Too many colonies were present; too numerous to count (TNTC). TNTC is generally defined as >150 colonies. B6 Coliform-Estimated Value. Blank contamination evident. B7 Coliform-Many non-coliform or non-enterococcus colonies or interfering non-coliform or non-enterococcus growth present. In this cc 1361 MPN-No wells or tubes gave a positive reaction. Value based upon the appropriate MPN Index and reported as a less than "<" valu BB2 MPN-All wells or tubes gave positive reactions. Value based upon the MPN Index and reported as a greater than ">" value. C Total residual chlorine was present in sample upon receipt in the laboratory; value is estimated. G1 BOD-The dissolved oxygen (DO) depletion of the dilution water blank exceeded 0.2 mg/L. G2 BOD-The bacterial seed controls did not meet the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at lea! G3 BOD-No sample dilution met the requirement of a DO depletion of at least 2.0 mg/L and/or a DO residual of at least 1.0 mg/L. G4 BOD-Evidence of toxicity. This is generally characterized by a significant increase in the BOD value as the sample concentration de G5 BOD-The glucose/ glutamic acid standard exceeded the range of 198 ± 30.5 mg/L. G6 BOD-The calculated seed correction exceeded the range of 0.6 to 1.0 mg/L. G7 BOD-Less than 1 mg/L DO remained for all dilutions set. The reported value is an estimated greater than value and is calculated foi G8 BOD-Oxygen usage is less than 2 mg/L for all dilutions set. The reported value is an estimated less than value and is calculated for G9 BOD-The DO depletion of the dilution water blank produced a negative value. J1 Surrogate recovery limits have been exceeded. J2 The reported value failed to meet the established quality control criteria for either precision or accuracy. WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 2 of 3 .NC D`W X Laboratory Section 9?,�sufts/Sampre Comments/Qualifier Definitions Sample ID: AC68817 Result/ Method Analysis - -- - J3 The sample matrix interfered with the ability to make any accurate determination. J4 The data is questionable because of improper laboratory or field protocols (e.g., composite sample was collected instead of grab, p J5 Temperature limits exceeded (samples frozen or >6°C) during transport or not verifiable (e.g., no temperature blank provided): non- J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. R This qualifier is used to identify analyte concentration exceeding the upper calibration range of the analytical instrument/method. Th J8 Temperature limits exceeded (samples frozen or >6°C) during storage, the data may not be accurate. J9 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J10 Unidentified peak; estimated value. J11 The reported value is determined by a one -point estimation rather than against a regression equation. The estimated concentration J12 The calibration verification did not meet the calibration acceptance criterion for field parameters. M Sample and duplicate results are 'but of control'. The sample is non -homogenous (e.g., VOA soil). The reported value is the lower N1 Presumptive evidence and estimated value. The component has been tentatively identified base on mass spectral library. N2 There is an indication that the analyte is present, but quality control requirements for confirmation were not met (i.e., presence of N3 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N4 This code shall be used if the level is too low to permit accurate quantification, but the estimated concentration is less than the labo N5 The component has been tentatively identified based on a retention time standard. Q1 Holding time exceeded prior to receipt by lab. Q2 Holding time exceeded following receipt by lab. P Elevated PQL* due to matrix interference and/or sample dilution. S Not enough sample provided to prepare and/or analyze a method -required matrix spike (MS) and/or matrix spike duplicate (MSD). U Indicates that the analyte was analyzed for but not detected above the reported practical quantitation limit*. The number value repot X1 Sample not screened for this compound. X2 Sampled, but analysis lost or not performed -field error. X3 Sampled, but analysis lost or not performed -lab error. V Indicates the analyte was detected in both the sample and the associated method blank. Note: The value in the blank shall not be s Y Elevated PQL* due to insufficient sample size. Z1 Inability to analyze the sample. Z2 Questions concerning data reliability. U, J6 The laboratory analysis was from an unpreserved or improperly chemically preserved sample. The data may not be accurate. UU Indicates that the analyte was not detected by a screen analysis. The number value was determined by a one -point estimation at tt WSS Chemistry Laboratory>> 1623 Mail Service Center, Raleigh, NC 27699-1623 (919) 733-3908 "Not Detected" or "U" does not indicate the sample is analyte free but that the analyte is not detected at or above the PQL. Page 3 of 3 F107 Environmental Chemists, Inc. 6602 Windmill Way, Wilmington, NC 28405 • 910.392.0223 Lab • 910.392.4424 Fax 710 Bowsertown Road, Manteo, NC 27954 • 252.473.5702 Lab/Fax 255-A Wilmington Highway, Jacksonville, NC 28540 • 910.347.5843 Lab/Fax ANALYTICAL & CONSULTING CHEMISTS info@environmentalchemists.com NCDENR-DWR Date of Report: Oct 24, 2019 127 N. Cardinal Drive Ext. Manteo Report #: 19M-1897 Wilmington NC 28405 Report #: 2019-17695 Attention: David May Customer ID: 09010049 Project ID: Columbia WWTP Lab ID Sample ID: W3338 Collect Date/Time Matrix Sampled by 19-45150 Site: Columbia WWTP 10/16/2019 11:59 AM Water Robbie Bullock Test Method Results Date Analyzed Enterococci EPA 1600 138est Colonies/100ml- 10/16/2019 Comment: Reviewed by: A k Report #:: 2019-17695 Page 1 of 1 -4 a B-F CL m t;j Ej n LAB ID rp 0 -3 2 samp ;..i. tm-1 I " Type n,tz: c Carnpnsire rn p a or ct 'v cm 0 )-a y Q v, contshLer or G) =-. Chlorbxe D!l C>S r k- NONE 61, -7- t7- CD HCL Q. TT O rt ID lq.OH nuo cr OTEEIM t4 6 Ire Z6