Loading...
HomeMy WebLinkAbout20191696 Ver 1_PCN Form Submission (2)_20191210DWR Division of Water Resources Pre -Construction Notification (PCN) Form September 29, 2018 Ver 3 Initial Review Has this project met the requirements for acceptance in to the review process?* r Yes r No Is this project a public transportation project?* C Yes r No Change only if needed. BIMS # Assigned 20191696 Is a payment required for this project?* r No payment required r Fee received r Fee needed - send electronic notification Reviewing Office * Fayetteville Regional Office - (910) 433-3300 Information for Initial Review 1a. Name of project: Winder Station/Vass Subdivision 1a. Who is the Primary Contact?* Lauren Norris -Heflin 1b. Primary Contact Email:* lauren.norris-heflin@timmons.com Date Submitted 12/10/2019 Nearest Body of Water unnamed tributary of Little River Basin Cape Fear Water Classification WS-III;HOW Site Coordinates Latitude: Longitude: 35.250536-79.280729 A. Processing Information County (or Counties) where the project is located: Moore Is this project a public transportation project?* r Yes r No 1a. Type(s) of approval sought from the Corps: W Section 404 Permit (wetlands, streams and waters, Clean Water Act) r Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) 1b. What type(s) of permit(s) do you wish to seek authorization? * Nationwide Permit (NWP) * Regional General Permit (RGP) 7 Standard (IP) Version#* 1 What amout is owed?* IT $240.00 r $570.00 Select Project Reviewer* Chad Turlington:eads\ccturlington 1c. Primary Contact Phone:* (919)866-4943 V 1c. Has the NWP or GP number been verified by the Corps? r Yes r No Nationwide Permit (NWP) Number: 29 - Residential Developments NWP Numbers (for multiple NWPS): 1d. Type(s) of approval sought from the DWR: W 401 Water Quality Certification - Regular r 401 Water Quality Certification - Express r Non-404 Jurisdictional General Permit r Riparian Buffer Authorization r Individual Permit le. Is this notification solely for the record because written approval is not required? For the record only for DWR401 Certification: r Yes r No For the record onlyfor Corps Permit: r Yes r No 1f. Is this an after -the -fact permit application?* r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? r Yes r No Acceptance Letter Attachment 1h. Is the project located in any of NC's twenty coastal counties? r Yes r No 1j. Is the project located in a designated trout watershed? r Yes r No B. Applicant Information 1d. Who is applying for the permit? W Owner r Applicant (other than owner) le. Is there an Agent/Consultant for this project?* r Yes r No 2. Owner Information 2a. Name(s) on recorded deed: CW Land Development, LLC 2b. Deed book and page no.: 4696,436 2c. Responsible party: 2d.Address Street Address PO Box174 Address Line 2 City Olivia Postal / Zip Code 28368-0174 2e. Telephone Number: (910)578-3445 2g. Email Address:* vveaver.realtor@gmail.com 4. Agent/Consultant (if applicable) 4a. Name: Lauren Norris -Heflin State / Province / Region NC Country USA 2f. Fax Number: (910)485-6700 4b. Business Name: Timmons Group 4c.Address Street Address 5410 Trinity Road Address Line 2 Suite 102 City Raleigh Postal / Zip Code 27607 4d. Telephone Number: (919)866-4943 4f. Email Address:* lauren.norris-heflin@timmons.com Agent Authorization Letter* Sig nedAgentFo rmC W La nd. pdf State / Prmince / I3gion NC Country USA 4e. Fax Number: 306.99KB C. Project Information and Prior Project History C^U 1. Project Information 1b. Subdivision name: (if appropriate) 1c. Nearest municipality/ town: Vass, NC 2. Project Identification 2a. Property Identification Number: 2b. Property size: 951411662337 26.1 2c. Project Address Street Address 355 Main Street Address Line 2 Cty State / Province / legion Vass NC Postal / Zip Code Country 28394 USA 3. Surface Waters 3a. Name of the nearest body of water to proposed project: unnamed tributary of Little River 3b. Water Resources Classification of nearest receiving water:* WS-III;HQW 3c. What river basin(s) is your project located in?* Cape Fear 3d. Please provide the 12-digit HUC in which the project is located. 030300040308 4. Project Description and History 4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application:* The proposed site encompasses approximately 26.1-acres and is located at 355 Main Street, within the Town of Vass, in Moore County, North Carolina. The project site is a single phase with no additional phases. The project site is currently comprised of forested land. It is bound to the north, south, east, and west by low density residential and forested land Per review of the USGS 7.5-Minute Topographic Mapping for the area, an unnamed tributary of the Little River is located immediately off -site to the north of the project site. No portion of this tributary was noted on -site during the delineation or Jurisdictional Determination site visit. However, two forested wetland areas are located within the northern portion of the project site and along the northern boundary, in the vicinity of this reported stream location. The project site is located within the Cape Fear River Basin (I2-digitHUC 030300040308), and drains to the north-northeast toward an unnamed tributary of the Little River. This unnamed tributary drains southwesterly into the Little River, which is classified as a High Quality Water (HQW). According to FEMA FIRM #3710951400J (effective 10/17/2006), the project site is located within Zone Xand is therefore not located Within the 100-year floodplain or regulatory floodway. A wetland delineation was completed by Timmons Group on September 25, 2018. Confirmation of the delineated boundaries was received from Ross Sullivan of the USACE on October 18, 2018. No Action ID was assigned to the site. 4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?* r Yes r No r Unknown 4d. Attach an 8 1/2 X 11 excerpt from the most recent version of the USGS topographic map indicating the location of the project site. (for DWR) Figure 1 - VIC.pdf 472.09KB 4e. Attach an 8 1/2 X 11 excerpt from the most recent version of the published County NRCS Soil Survey map depicting the project site. (for DWR) Figure 5 - NRCS.pdf 573.79KB 4f. List the total estimated acreage of all existing wetlands on the property: 1.59 4g. List the total estimated linear feet of all existing streams on the property: 4h. Explain the purpose of the proposed project,* The purpose of the project is to construct a single-family residential subdivision with community cohesion and the necessary amenities within the eastern section of Moore County. 4i. Describe the overall project in detail, including indirect impacts and the type of equipment to be used:* The proposed residential development, known as Winder Station, will consist of 70 single-family lots and amenities in addition to roadway, stormwater control measures (SCMs), and utility improvements (i.e. public water supply and sanitary sewer alignment). The project is located to the west of Union Church Rd. and to the north of highway U.S. 1. In addition, the project requires connection to existing utility easements that are located offsite. Due to grading requirements, three (3) of the proposed lots are expected to permanently impact a total of 0.03-acres of palustrine forested (PFO) wetland area onsite. The attached Construction Drawings and Impact Maps include the specific details of the proposed construction. Additional impacts to waters of the U.S. are not proposed. The proposed project is a single and complete project with appropriate land use control measures in place for specific areas which require them. Traditional equipment will be used consisting of front-end loaders, bulldozers, paving equipment, graders, and earth movers. 4j. Please upload project drawings for the proposed project. Winder Station 2019-11-25.pdf 13.47MB Figure 7 - WTIM.pdf 2.67MB 5. Jurisdictional Determinations 5a. Have the wetlands or streams been delineated on the property or proposed impact areas?* r Yes r No Comments: Delineation completed by Timmons September 2018 5b. If the Corps made a jurisdictional determination, what type of determination was made?* r Preliminary r Approved r Not Verified r Unknown r N/A Corps AID Number: SAW-2018-02018 5c. If 5a is yes, who delineated the jurisdictional areas? Name (if known): George Buchholz Agency/Consultant Company: Timmons Group Other: O Unknown 5d. List the dates of the Corp jurisdiction determination or State determination if a determination was made bythe Corps or DWR Ross Sullivan of the USACE emailed George Buchholz on 10/18/18 stating '[ajfter reviewing the preliminary jurisdictional determination request package, I have determined that the delineation map that you provide to me on 10/5/2018 entitled "Figure 6: Wetlands and Waters of the U.S. Delineation Map" accurately depicts the approximately limits of any potentially jurisdictional WoUS within the project area." 5d1. Jurisdictional determination upload 10.18.18 - USACE Emailed Delineation Confirmation. pdf 172.51 KB 6. Future Project Plans 6a. Is this a phased project?* r Yes r No Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity? D. Proposed Impacts Inventory 1. Impacts Summary 1a. Where are the impacts associated with your project? (check all that apply): W Wetlands r Streams -tributaries r Open Waters r Pond Construction 2. Wetland Impacts r Buffers 2a1 Reason (?) 2b. Impact type*(?) 2c. Type of W.* 2d. W. name * 2e. Forested* 2C Type of 2g. Impact Jurisdicition*(?) area grading P Small -Basin Wetland A Yes Corps 0.025 (acres) grading P Headwater Forest B Yes Corps 0.004 (acres) 2g. Total Temporary Wetland Impact 0.000 2g. Total Wetland Impact 0.029 2h. Comments: E. Impact Justification and Mitigation 1. Avoidance and Minimization 2g. Total Permanent Wetland Impact 0.029 1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project: Impacts to jurisdictional features have been avoided and minimized to the maximum extent practicable by incorporating resourceful site planning, including the utilization of the wetland delineation to adjust the layout to avoid and minimize impacts. Avoidance and minimization measures were also accomplished during the design phase of the project. The proposed impacts are required in order to meet the minimal number of lots and lot sizes per zoning requirements to make the project viable. The proposed development was designed to maximize open, unimpaired space within and in the immediate vicinity of the delineated wetlands. 1b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques: Proper sedimentation and erosion control methods will be utilized during all phases of construction and installation as described in accordance with the requirements of the North Carolina Department of Environment and Natural Resources: Erosion Control Planning and Design Manual (May 2013) and local codes. All work will take place during dry conditions and can be facilitated from high, non -jurisdictional, stable ground. The contractor shall install silt fence, inlet protection, sediment traps, diversion ditches, temporary coffer dams, tree protection, clearing only as necessary to install devices. All erosion and sediment control measures will be checked for stability and operation following every runoff producing rainfall, but in no case less than once every week. Any needed repairs will be made immediately to maintain all measures designed. An erosion control inspections report is required and will be kept by the owner's representative. Temporary seeding and permanent seeding plans are included to restore impacted areas. The project will meet all relative requirements of Best Management Practices and Engineered Stormwater Control Structures as outlined through State and Local Stormwater Rules. Measures will be taken to prevent oil, tar, trash, debris and other pollutants from entering the adjacent jurisdictional features. Any excess excavated materials not utilized as back fill will be placed and contained within upland areas and permanently stabilized to prevent erosion into adjacent jurisdictional features. Therefore, stockpiling of excavated material within jurisdictional waters of the U.S. will be strictly prohibited as part of the construction of this project. All project construction activities initiated within jurisdictional waters of the U.S. will be carried to completion in an expeditious manner to minimize the period of disturbance within the jurisdictional streams. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? r Yes r No 2b. If this project DOES NOT require Compensatory Mitigation, explain why: Compensatory Mitigation is not required as the proposed development will result in less than 0.1-acres of wetland impact. F. Stormwater Management and Diffuse Flow Plan (required by DWR) 1. Diffuse Flow Plan 1a. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? r Yes r No If no, explain why: This site is located within the Cape Fear River Basin and therefore not located within an area subject to NC Riparian Buffer Protection Rules. Further, no streams were identified on -site. 2. Stormwater Management Plan 2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250?* r Yes r No 2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)? r Yes r No 2c. Does this project have a stormwater management plan (SMP) reviewed and approved under a state stormwater program or state -approved local government stormwater program? r Yes r No 2d. Which of the following stormwater management program(s) apply: r Local Government R State State Stormwater Programs r Phase II 9 HWQ or ORW r Coastal Counties P Other Water Supply Comments: Additionally, although not identified as a state approved local government program, the Town of Vass has contracted a consultant to review stormwater plans to ensure they are sufficient per local guidelines. G. Supplementary Information 1. Environmental Documentation 1a. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?* r Yes r No 2. Violations (DWR Requirement) 2a. Is the site in violation of DWR Water Quality Certification Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or Riparian Buffer Rules (15A NCAC 2B .0200)? * r Yes r No 3. Cumulative Impacts (DWR Requirement) 3a. Will this project result in additional development, which could impact nearby downstream water quality?* r Yes r No 3b. If you answered "no," provide a short narrative description. The entire project is a single and complete project with appropriate land use control measures in place for specific areas which require them. 4. Sewage Disposal (DWR Requirement) 4a. Is sewage disposal required by DWR for this project?* r Yes r No r N/A 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or habitat?* r Yes r No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts?* r Yes r No 5c. If yes, indicate the USFWS Field Office you have contacted. Raleigh 5d. Is another Federal agency involved?* r Yes r No 5e. Is this a DOT project located within Division's 1-8? r Yes r No 5f. Will you cut any trees in order to conduct the work in waters of the U.S.? r Yes r No 5g. Does this project involve bridge maintenance or removal? r Yes r No 5h. Does this project involve the construction/installation of a wind turbine(s)?' r Yes r No r Unknown 51. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.? r Yes r No 5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? The United States Fish and Wildlife Service and North Carolina Natural Heritage Program data sources were used. The species listed by IPaC include: red -cockaded woodpecker, American chaffseed, and Michau)(s sumac. No critical habitats are identified as being located within or in the vicinity of the project area. The red -cockaded woodpecker's habitat includes pine trees 60 years or older. American chaffseed's habitat includes open, moist pine flatwoods and fire -maintained savannas with sandy, moist to dry soils. Michaux's sumac prefers disturbed open areas or edges. Based on these habitat descriptions and habitat observed on -site, it is the opinion of Timmons Group that the proposed action will have no effect on protected species. Timmons Group initiated consultation with the USFWS Raleigh Field Office on November 27, 2019 to verify this no effect determination. If comments are received prior to the completion of this PCN, they will be forwarded on immediately. NCNHP does not indicate the presence of any of the species mentioned above within a one -mile radius of the project area. Consultation Documentation Upload 11.25.19_IPaC Species Report.pdf 195.04KB 11.25.19_NCNHP Species Report.pdf 1.12MB Winder Station T&E Review Package (PN 38790).pdf 5.04MB 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as an Essential Fish Habitat?* r Yes r No 6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?* NOAA's Essential Fish Habitat Mapper - https://vmw.habitat.noaa.gov/application/efhmapper/indexhtml ..habitat.noaa.gov/application/efhmapper/indexhtml 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?* r Yes r No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources?* The data used comes from the cultural resources database at the North Carolina Office of State Archeology (OSA). Per a cultural resources review, the proposed project should not adversely affect historic resources due to the absence of listed resources within the project area. Further, the proposed development should not significant alter the setting of the surrounding area. 7c. Historic or Prehistoric Information Upload Winder Cultural Report - Jay 12.09.19.pdf 517.96KB Architectural Resources_1-mile.pdf 190.38KB Architectural Resources 1-mile spreadsheet.pdf 62.87KB 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA-designated 100-year floodplain?* r Yes r No 8c. What source(s) did you use to make the floodplain determination?* Upon review of the FEMA Flood Insurance Rate Map #3710951400J (effective 10/17/2006), the site is located within Zone X Area of Minimal Flood Hazard. Therefore, the site is located outside of the 100-year floodplain and the regulated floodway. Miscellaneous Comments Miscellaneous attachments not previously requested. Figure 2 - HUC.pdf 3.61 MB Figure 3 - EIM.pdf 3.65MB Figure 4 - Parcel Map.pdf 588.39KB Figure 6 - WTDM.pdf 4.27MB Signature W By checking the box and signing below, I certify that: • I have given true, accurate, and complete information on this form; • I agree that submission of this PCN form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); • I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND • I intend to electronically sign and submit the PCN form. Full Name Lauren Norris -Heflin Signature Date 12/10/2019 r TIMMONS GROUP YOUR ViSiON ACHIEVED THROUGH OURS. AGENT AUTHORIZATION and PROPERTY OWNER CERTIFICATION FORM All Blanks to be Filled in by Current Landowner The Department of the Army NCDENl2. — Division of Water Resources US Army Corps of Engineers 401 & Buffer Permitting Unit Wilmington District 1650 Mail Service Center PO Box 1990 Raleigh, NC 27699-1650 Wilmington, NC 28402-1890 To Whom It May Concern_ I, the undersigned, current property owner designate and authorize representatives of Timmons Group, Inc., to act on my behalf as my agent in the processing of permit applications, to furnish upon request supplemental information in support of applications, etc., from this day forward. This the 30 day of Se to ember, 2018_ (number) (Month) (Year) 1, the undersigned, a duly authorized owner of record of the property/properties identified herein, do authorize representatives of the Wilmington District, U_S_ Army Corps of Engineers (Corps) to enter upon the property herein described for the purpose of conducting on -site investigations and issuing a determination associated with Waters of the U.S. subject to Federal jurisdiction under Section 404 of the Clean Water Act and/or Section 10 of the Rivers and Harbors Act of 1899. This notification supersedes any previous correspondence concerning the agent for this project_ Project Name: Vass Mixed Use Location: 0 Fire Lane, Vass, NC 288394 / Property Owner's Name (Print):,/--' W ,� Property Owner's Signature: yj'/I_,,,,, 46V I Property Owner's Mailing Address: Property Owner's Telephone: �C Fax No_ I{,0 VJS:-�424" Property Owner's Email Address: We- vow, ✓&*-) M Ln rn ko io m a: rn w F_ E O V U) 0 E E Z 3 3 U.S.G.S. QUADRANGLE(S):DATE(S):WATERSHED(S):HYDROLOGIC UNIT CODE(S): TIMMONS GROUP JOB NUMBER:PROJECT STUD Y LIMIT S:LATITUDE:LON GIT UDE: VASS SUBDIVISIONMOORE, NORTH CAROLINAFIGURE 1: VICINITY MAP 38790 35.250536 -79.280729 26.01 ACRES NIAGRA & VASS2016 03030004CAPE FEAR RIVER BASIN These plans and associated docum ents are the exclusive property of TIM MONS GRO UP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. Path: R:\805\38790 - Vass Subdivision\GIS\Common Shared Exhibits\38790-VIC.mxd 5 0 1,000 2,000 3,000 4,000Feet Site limits are approximate.Topographic imagery from USGS. Site Limits ^_ 03020201 03030002 03020203 03030003 03040103 03030004 03040104 03030006 03030007 03040203 03030005 03040201 03040204 Legend ^_Site Marker Cape Fear River Basin Hydrologic Unit Code DRAWING DESCRIPTION PROJECT NAME & LOCATION SHEET NUMBERSCALE 1 DATE 09/21/2018 DESIGNED BY / DRAWN BY PROJECT NAME A. MEHFOUD VASS SUBDIVISION FIGURE 2:HYDROLOGICUNIT CODE MAP REVISIONS MM/DD/YY#DESCRIPTION These plans and associated documents are theexclusive property of TIMMONS GROUP andmay not be reproduced in whole or in part andshall not be used for any purpose whatsoever,inclusive, but not limited to construction, bidding,and/or construction staking without the expresswritten consent of TIMMONS GROUP. PROJECT NUMBER38790VASS SUBDIVISIONTHIS COUNTY,VIRGINIA1001 Boulders Parkway, Suite 300Richmond, VA 23225TEL 804.200.6500www.timmons.com[ PLANS PRINTED AS 11X17 ARE HALF SCALE03 6 Miles R:\805\38790 - Vass Subdivision\GIS\Common Shared Exhibits\38790-HUC.mxd NOTES:Site marker is approximate.HUC from USGS.Topographic basemap fromEsri Online. H:1 " = 3 Miles Mai n St West St Pi n e St Seaboard StUS 1 BypassNorth AveScott Ave US1BypassBrewer Ave H igh la nd A veSmith StSouth StUS 1 BypassFire Ln Johnson StFuB GhB VuD VuB CaC Bb FaB AeB GhB AeD AeD Legend Project Study Limits - 26.0 Acres National Hydrography Dataset National Wetlands Inventory Hydric Soil Classification All Hydric Partially Hydric Non Hydric DRAWING DESCRIPTION PROJECT NAME & LOCATION SHEET NUMBERSCALE1 DATE 09/21/2018 DESIGNED BY / DRAWN BY PROJECT NAME A. MEHFOUD VASS SUBDIVISION 1 " = 100 'H: FIGURE 3:ENVIRONMENTALINVENTORY MAP REVISIONS MM/DD/YY#DESCRIPTION These plans and associated documents are theexclusive property of TIMMONS GROUP andmay not be reproduced in whole or in part andshall not be used for any purpose whatsoever,inclusive, but not limited to construction, bidding,and/or construction staking without the expresswritten consent of TIMMONS GROUP. PROJECT NUMBER38790VASS SUBDIVISIONMOORE COUNTY,NORTH CAROLINA1001 Boulders Parkway, Suite 300Richmond, VA 23225TEL 804.200.6500www.timmons.com[ PLANS PRINTED AS 11X17 ARE HALF SCALE0100200 SCALE (FEET) R:\805\38790 - Vass Subdivision\GIS\Common Shared Exhibits\38790-EIM.mxd NOTES:Project Limits areapproximate.NWI from US Fish andWildlife Service.Soils data from SSURGO.National HydrographyDataset from USGS.Aerial imagery from NCOneMap. Ma puni t S ym bol Ma puni t Na m eAeBAiley loamy s and, 2 to 8 perc ent s lopesAeDAiley loamy s and, 8 t o 15 perc ent s lopesBbBibb loam, 0 t o 2 perc ent s lopes , frequent ly floodedCaCCandor s and, 4 t o 12 perc ent s lopesFaBFuquay loamy s and, 0 t o 6 perc ent s lopesFuBFuquay-Urban land c omplex , 0 t o 6 perc ent s lopesGhBGilead loamy s and, 2 t o 8 perc ent s lopesVuBVaucluse-Urban land c omplex , 2 t o 8 perc ent s lopesVuDVaucluse-Urban land c omplex , 8 t o 15 perc ent s lopes Moore County S oi l s U.S.G.S. QUADRANGLE(S):DATE(S):WATERSHED(S):HYDROLOGIC UNIT CODE(S): TIMMONS GROUP JOB NUMBER:PROJECT STUD Y LIMIT S:LATITUDE:LON GIT UDE: VASS SUBDIVISIONMOORE, NORTH CAROLINAFIGURE 4: PARCEL MAP 38790 35.250536 -79.280729 26.01 ACRES NIAGRA & VASS2016 03030004CAPE FEAR RIVER BASIN These plans and associated docum ents are the exclusive property of TIM MONS GRO UP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. Path: R:\805\38790 - Vass Subdivision\GIS\Common Shared Exhibits\38790-ParcelMap.mxd 5 0 280 560 840 1,120Feet Site limits are approximate.Topographic imagery from USGS. Weaver and Thomas Partnership951411662337 U.S.G.S. QUADRANGLE(S):DATE(S):WATERSHED(S):HYDROLOGIC UNIT CODE(S): TIMMONS GROUP JOB NUMBER:PROJECT STUD Y LIMIT S:LATITUDE:LON GIT UDE: VASS SUBDIVISIONMOORE, NORTH CAROLINAFIGURE 5: NR CS SOIL SURVEY MAP 38790 35.250536 -79.280729 26.01 ACRES NIAGRA & VASS2016 03030004CAPE FEAR RIVER BASIN These plans and associated docum ents are the exclusive property of TIM MONS GRO UP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP. Path: R:\805\38790 - Vass Subdivision\GIS\Common Shared Exhibits\38790-NRCS.mxd 5 0 450 900 1,350 1,800Feet Site limits are approximate.Soils from NRCS web soil survey. Site Limits DRAWING DESCRIPTION PROJECT NAME & LOCATION SHEET NUMBERSCALE1 DATE 09/24/2018 DESIGNED BY / DRAWN BY PROJECT NAME A. MEHFOUD VASS SUBDIVISION AA gM/gM/ gM/ gM/ gM/ gM/ gM/ gM/ gM/ gM/ gM/ !(A !(B FDS-30A1-2FDS-30A1-3 30A1-2 30A1-4 30B1-2 30B1-5 30B1-7 30B1-10 /PFO-30C1-1 30B1-14 30B1-16 30B1-18 30B1-19 30C1-2 Mai n St US1BypassBrewer Ave North AveUS 1 BypassSmith StUS 1 BypassSeaboard StSouth StH igh la nd A veFire Ln Johnson St3563523513503363313303 2 9328327326320319312310309308307306305303302301300299298297296295294 3 4 5344343 342341340339338316315313311304 35 5 353 3 4 6 32532432332232131832 9328 32 4 320330325323 331 326299298297296295300293320 3 1 7 3213183413 4 03 3 9 3 3 7305302 3 4 0 3 3 8 307 306 2982 9 7 323322354 3 4 9 3 4 8 34 7 3373353 3 4 333 33231731 4 3 3 8 3571 " = 100 'H: FIGURE 6:WETLANDS ANDWATERS OF THEU.S. DELINEATIONMAP REVISIONS MM/DD/YY#DESCRIPTION These plans and associated documents are theexclusive property of TIMMONS GROUP andmay not be reproduced in whole or in part andshall not be used for any purpose whatsoever,inclusive, but not limited to construction, bidding,and/or construction staking without the expresswritten consent of TIMMONS GROUP. PROJECT NUMBER38790VASS SUBDIVISIONMOORE COUNTY,NORTH CAROLINA1001 Boulders Parkway, Suite 300Richmond, VA 23225TEL 804.200.6500www.timmons.com[ PLANS PRINTED AS 11X17 ARE HALF SCALE0100200 SCALE (FEET) R:\805\38790 - Vass Subdivision\GIS\WTDM\38790-WTDM.mxd 1. Waters of the U.S. within theproject study limits have beenlocated using submeter, BluetoothGPS antennas by TimmonsGroup.2.Waters of the U.S. have notbeen confirmed by the U.S. ArmyCorps of Engineers.3. Project limits are approximate.4. Topography based on USGSLiDAR.5. Cowardin StreamClassifications are based solelyon field observations. No formalStream assessment methodologywas completed to determine theseCowardin Classifications.Legend Project Limits - 26.01 Acres ")X Stream Identifier !(X Wetland Identifier g M/Wetland Flag A Field Data Station Palustrine Forested (PFO) W etlands Topograp hic Contours Major - 10 Feet Minor - 1 Foot PFO(s q ft)PSS(sq ft)PEM(s q ft)POW(sq ft)R3(lf)R4(lf)R6(lf)Ditc h(lf)A 1,086 NT/V B 68,068 NT/V Tota l 69,153 0 0 0 0 0 0 0 * T=Tidal; NT=Non-tidal; V=Vegetated; NV=Non-Veget ated; PFO=Palustrine Fores ted W etland; PSS=Palus trine Scrub-Shrub W etland; PEM=Palustrine Emergent W etland; POW = Palustrine Open W at er; EIW = Es tuarine Intertidal W etlands; R3= Upper Perennial Streams ; R4=Intermittent Streams; R6 = Ephemeral Streams Res ource Identific ation Confirma tion Res ourceDescriptionNotes* Tota l W e tla nd Are a = Tota l Stre a m Le ngth = 69,153 sq ft 0 lf 1.59 a c D D DDDDDDDDDD D D D DD D DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD DDDDDDDDDDDDDDOL DOLDOL DOL D O L D O L DOLDOL DOLDOLDOLDOLDOLDOL DOL DOLDOL DOL DOL DOL DOL DOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOL DOL DOL DOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOL DOL!(1 !(2 357356314308305304315309306300297316303301299336 3 2 7 337328338335 3 3 933 1332 329317310311 3 0 7 3293233 4 0339 337321317 2972933 0 0 299296294323321353 3 4 9 334 3333 3 0 326325 324322320 313 312302328 3 3 8 332305 3 4 0 298306 Mai n St US1 BypassNorth AveBrewer AveSmith StSeaboard StSouth StH ighla nd A veFire Ln US1BypassJohnson StPath: Y:\805\38790 - Vass Subdivision\GIS\WTIM\38790-WTIM.mxdLegend Project Study Limi ts - 29.6 Acr es !(X Wetland Im pac t DOL Limits of Di sturbance Proposed Grading - MajorProposed Grading - MinorPermanent Wetl and ImpactPalustrine Forested (PFO) WetlandsExisting Topog rap hic Con tou rsMajor - 10 FeetMinor - 1 F oot ³ 0 200 400100 Feet 1. Waters of the U.S. within the project study limits have beenlocated using submeter, Bluetooth GPS antennas by TimmonsGroup.2.Waters of the U.S. have not been confirmed by the U.S. ArmyCorps of Engineers until stamped.3. Project limits are approximate.4. Topography based on USGS LiDAR.5. Cowardin Stream Classifications are based solely on fieldobservations. No formal Stream assessment methodology wascompleted to determine these Cowardin Classifications.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but not limited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.EnvironmentalJOB NUMBER CHECKED BY SCALE SHEET NO. DATE DESIGNED BY DRAWN BYYOUR VISION ACHIEVED THROUGH OURSSite DevelopmentResidentialInfrastructureDATEREVISION DESCRIPTIONTHIS DRAWING PREPARED AT THE1001 Boulders Parkway, Suite 300 | Richmond, VA 23225TEL 804.200.6500 FAX 804.560.1648 www.timmons.comCORPORATE OFFICETechnologyVASS SUBDIVISIONFIGURE 7: PRELIMINARY JURISDICTIONAL WATERS OF THE U.S. IMPACTS MAP38790MOORE COUNTY, NORTH CAROLINA11/26/2019 L. WHEELER L. WHEELER L. NORRIS-HEFLIN 1 OF 1 1 " = 200 'Johnson StFire Ln South StH igh la nd A veSmith StMai n St Ma in S t Temporary Permanent Te mporary Pe rmanent Temporary Permanent11,08621560 sq ft 1,242 sq ft 0 sq ft 0 sq ft0.00 ac 0.03 ac 0.00 ac 0.00 a cTotal 0 lf 0 lf Impa cts Table Impact ID Wetland (sq. ft)Strea m (lf)Impact Conversion Impact CONSTRUCTION DRAWINGS VASS, MOORE COUNTY, NORTH CAROLINA WINDER STATION AT VASS VICINITY MAP SCALE: 1" = 500'COVER SHEETC0.0 SITE MAIN ST . JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C0.0-COVR.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 SINGLE FAMILY RESIDENTIAL 951411662337 PROPOSED USE: PIN: WINDER STATION AT VASSPROJECT: ENGINEER:DANIELLE KIRK, PE PHONE: 984-255-2364 RALEIGH, NC 27607 5410 TRINITY ROAD; SUITE 102 TIMMONS GROUP EMAIL: DANIELLE.KIRK@TIMMONS.COM 910-578-3445 CW LAND DEVELOPMENT, LLCDEVELOPER: SITE DATA ZONING:R-1 SITE AREA:26.47 ACRES 18.00 ACRES 70 DISTURBED AREA TOTAL PROPOSED LOTS:B R EW E R A V E .SOUTH ST.JOHN S O N S T. FI R E L N .SEABOARD ST.SHEET INDEX SHEET NUMBER SHEET TITLE C0.0 COVER SHEET C1.0 EXISTING CONDITIONS & DEMOLITION PLAN C2.0 SITE PLAN C3.0 UTILITY PLAN C4.0 GRADING & DRAINAGE PLAN C4.1 STORM DRAINAGE SCHEDULE C5.0 SEDIMENTATION & EROSION CONTROL PLAN C6.1 FIRE LANE PLAN & PROFILE C6.2 CONDUCTOR COURT (STA 10+00 TO 19+00) PLAN & PROFILE C6.3 CONDUCTOR COURT (STA 18+00 TO 27+00) PLAN & PROFILE C6.4 SANITARY SEWER OUTFALL A PLAN & PROFILE C7.1 SCM 1 DETAILS C7.2 SCM 2 DETAILS C7.3 SCM 3 DETAILS C8.1 NOTES & DETAILS C8.2 NOTES & DETAILS C8.3 NOTES & DETAILS C8.4 NOTES & DETAILS C9.0 LANDSCAPE PLAN P.O. BOX 174, OLIVIA, NC 28368 SANSANWWWWS S SAN SAN W W S WWWN/F JOHN D VIA PIN: 951400663652 DB: 4286, PG: 224 WETLANDS N/F JAMES & SOPHIA VARELA PIN: 951400662776 DB: 5063, PG: 332 N/F MATTHEW S, SANDERS PIN: 951411661825 DB: 2974, PG: 383 N/F KAREN B MCNEIL PIN: 951411567358 DB: 2797, PG: 550 N/F ED-MAR FARMS, LLC PIN: 951411566662 DB: 4259, PG: 468 N/F JEFFERY L & SUSAN M LASSITER PIN: 951411578023 DB: 2004E, PG: 222 N/F ROY L & PEGGY RAMEY PIN: 951411567806 DB: 318, PG: 49 N/F ROY L & PEGGY RAMEY PIN: 951411673267 DB: 463, PG: 350 N/F LEWIN M BLUE PIN: 951411668827 DB: 5021, PG: 409 N/F ANTHONY PELLIGRINO PIN: 951411667977 DB: 2393, PG: 372 N/F BONITA Y BLUE PIN: 951400677017 DB: 2041, PG: 508 N/F VIRGINIA L DEAN PIN: 951411676175 DB: 1990E, PG: 424 N/F CHARLES V & FRANCES C WALTERS PIN: 951411669315 DB: 789, PG: 548 N/F CALVIN B JR & JULIE L TERRY PIN: 951411666296 DB: 1106, PG: 57 N/F MARINTHA LASSITER PIN: 951411665123 DB: 2012E, PG: 691 N/F GERALD & CYNTHIA F MOORE PIN: 951411558431 DB: 3119, PG: 336 N/F LESLIE S PARKER PIN: 951411559584 DB: 3648, PG: 237 N/F LOIS A FAULKENBURY PIN: 951411651666 DB: 500, PG: 680 N/F ANTHONY R & JENNIFER M DIMAIO PIN: 951411654803 DB: 5131, PG: 176 N/F MARINTHA LASSITER PIN: 951411655975 DB: 2012E, PG: 691 WETLANDS RIM: 306.04' INV IN (SE): 300.54' INV OUT (NW): 300.44' RIM: 308.60' INV IN (SE): 298.40' INV OUT (NW): 298.30' RIM: 303.55' INV IN (SE): 297.25' INV OUT (NW): 297.20' N/F JOANN HIPP PIN: 951411556971 DB: 748, PG: 343 N/F JOANN HIPP PIN: 951411554856 DB: 292, PG: 319 N/F DONALD & ANNIE R BRIGGS PIN: 951411563221 DB: 426, PG: 600 N/F ANESA DARLING PIN: 951411564477 DB: 5110, PG: 357 N/F NICOLAS D & KRISTI R SOUTH PIN: 951411565398 DB: 4825, PG: 262 N/F JEFFERY L & SUSAN M LASSITER PIN: 951411670139 DB: 2004E, PG: 222 N/F DANA A SMITH PIN: 951411671222 DB: 3450, PG: 277 N/F KENNETH R & JUDY M HALES PIN: 951411672214 DB: 935, PG: 24 N/F VIRGINIA L DEAN PIN: 951411674153 DB: 1990E, PG: 424 EXISTING WELL ACCESS EASEMENT TO BE ABANDONED EXISTING 6" CAST IRON WATER MAIN EXISTING 6" CAST IRON WATER MAIN EXISTING 1" CAST IRON WATER MAIN WETLANDS EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT N/F CW LAND DEVELOPMENT, LLC PIN: 951411662337 DB: 4696, PG: 436 SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY 310 315 320 330325330335 34 0 335305300 305 310 3 1 5 32032533034034530530 0295 3 0 0 305310335 N/F JENNIE C & SCOTT E OZLEY PIN: 951411652784 DB: 2871, PG: 397 FIRE LANE40' ROW SOUTH S T R E E T 60' ROW MAIN STREET60' ROWJOHNSON STREET 60' ROWBREWER AVENUE60' ROWN/F KAREN B MCNEIL PIN: 951411568524 DB: 2797, PG: 550 N/F ROY L & PEGGY RAMEY PIN: 951411567831 DB: 552, PG: 891 N/F JEFFERY L & SUSAN M LASSITER PIN: 951411579036 DB: 2004E, PG: 222 N/F VIRGINIA L DEAN PIN: 951411676252 DB: 1990E, PG: 424 N/F LEWIN BLUE & KAREN B MCNEIL PIN: 951411668863 DB: 2659, PG: 106 0 SCALE 1"=80' 160'80'NAD 83EXISTING CONDITIONS & DEMOLITION PLANC1.0 WETLANDS PROPERTY LINE EXISTING RIGHT-OF-WAY EXISTING ROAD CENTER EXISTING CONTOUR STREAM CENTERLINE 1.EXISTING CONDITIONS SHOWN ARE BASED ON FIELD SURVEY PERFORMED BY CHANDLER LAND SURVEYING ON 03/30/2017. 2.ADJOINER PROPERTY INFORMATION AND TOPOGRAPHIC DATA SHOWN HAVE BEEN COMPILED FROM MOORE COUNTY GIS. 3.PROJECT PROPERTY DOES NOT LIE IN A FEMA SPECIAL FLOOD HAZARD AREA PER FEMA FIRM MAP PANEL NO. 3710951400J DATED 10/17/2006. 4.ALL UTILITIES OR STRUCTURES NOT INDICATED FOR REMOVAL OR MODIFICATION ARE TO REMAIN AND BE PROTECTED FROM DAMAGE. 5.ALL WASTE MATERIAL GENERATED FROM CLEARING AND DEMOLITION ACTIVITIES SHALL BE DISPOSED OFF OFF-SITE IN ACCORDANCE WITH ALL APPLICABLE RULES AND REGULATIONS. 6.REMOVE TOPSOIL AND STOCKPILE APPROPRIATELY ON-SITE. ON-SITE TEMPORARY STOCKPILES SHALL BE LOCATED WITHIN CONSTRUCTION LIMITS. 7.ALL PAVEMENT OR CONCRETE TO BE REMOVED SHALL BE SAW CUT TO PROVIDE A STRAIGHT AND UNIFORM JOINT WITH NEW CONSTRUCTION. ANY EXISTING PAVEMENT, SIDEWALK, CURB & GUTTER, ETC. THAT MUST BE REMOVED TO ALLOW NEW CONSTRUCTION SHALL BE REMOVED AND REPAIRED PER THE SPECIFICATIONS AND DETAILS OR TO MATCH EXISTING CONDITIONS (WHETHER OR NOT SHOWN ON THE DRAWINGS TO BE REMOVED). UTILITY INSTALLATIONS MAY UTILIZE OPEN CUT OF PAVEMENTS UNLESS INDICATED OTHERWISE. TRENCH IN EXISTING ASPHALT SHALL BE PATCHED PER PAVEMENT REPAIR DETAIL. 8.PROTECT ALL ADJACENT PROPERTIES, THE GENERAL PUBLIC AND ALL OF THE OWNER'S FACILITIES. SHOULD DAMAGE OCCUR, NOTIFY ENGINEER IMMEDIATELY. 9.THE CONTRACTOR SHALL EMPLOY A QUALIFIED UTILITY LOCATOR SERVICE TO LOCATE ALL UNDERGROUND UTILITIES (INCLUDING BUT NOT LIMITED TO ELECTRICAL, TELEPHONE, GAS, CABLE, FIBER OPTIC) WITHIN THE LIMITS OF CONSTRUCTION. 10.VERIFY ALL ILLUSTRATED KNOWN UNDERGROUND ELEMENTS. EXERCISE REASONABLE EFFORTS TO PROTECT ANY UNKNOWN UNDERGROUND ELEMENTS. NOTIFY ENGINEER IMMEDIATELY IF UNKNOWN ELEMENTS ARE DISCOVERED THAT WOULD REQUIRE MODIFICATIONS TO THE PROPOSED DESIGN. 11.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND OSHA REGULATIONS. 12.EXISTING MANHOLES, VALVE BOXES, VAULTS, CLEANOUTS, UTILITY POLES, ETC. TO REMAIN WITHIN THE GRADING LIMITS SHALL BE ADJUSTED AS NEEDED TO FUNCTION PROPERLY WITH THE PROPOSED FINISHED GRADES (WHETHER OR NOT INDICATED TO BE MODIFIED). 13.GENERAL CONTRACTOR SHALL COORDINATE ALL PEDESTRIAN ACCESS PATH, LOCATIONS, LIGHTING, ETC. WITH OWNER. GENERAL NOTES LEGEND TOTAL SITE AREA CURRENT ZONING PIN NUMBER 26.47 AC. R-1 951411662337 SITE DATA JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C1.0-EXIS.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 OPEN SPACE AREA #1 189,468 SF 4.35 AC 18 13002 SF 0.30 AC 19 10991 SF 0.25 AC 20 12690 SF 0.29 AC 21 11085 SF 0.25 AC 22 13816 SF 0.32 AC31 6035 SF 0.14 AC 32 6470 SF 0.15 AC 33 5525 SF 0.13 AC 35 5490 SF 0.13 AC 40 6500 SF 0.15 AC 58 6247 SF 0.14 AC 65 7899 SF 0.18 AC 66 6740 SF 0.15 AC 68 6487 SF 0.15 AC 63 11161 SF 0.26 AC 67 7428 SF 0.17 AC 16 6456 SF 0.15 AC 15 5706 SF 0.13 AC 14 6514 SF 0.15 AC 44 6500 SF 0.15 AC 41 5720 SF 0.13 AC 42 6500 SF 0.15 AC 64 10298 SF 0.24 AC 17 5763 SF 0.13 AC 13 5706 SF 0.13 AC 3 7206 SF 0.17 AC 5 7075 SF 0.16 AC 4 8400 SF 0.19 AC 1 7020 SF 0.16 AC 70 7359 SF 0.17 AC 2 7245 SF 0.17 AC 69 7359 SF 0.17 AC 23 11882 SF 0.27 AC 29 9184 SF 0.21 AC 34 6250 SF 0.14 AC 36 6678 SF 0.15 AC 30 7361 SF 0.17 AC 37 6773 SF 0.16 AC 38 7424 SF 0.17 AC 28 6111 SF 0.14 AC 26 7574 SF 0.17 AC 24 10167 SF 0.23 AC 27 7981 SF 0.18 AC 25 9658 SF 0.22 AC 43 5720 SF 0.13 AC 49 6524 SF 0.15 AC 46 6250 SF 0.14 AC 45 7241 SF 0.17 AC 52 7494 SF 0.17 AC 59 6251 SF 0.14 AC 39 6406 SF 0.15 AC 57 6250 SF 0.14 AC 56 6250 SF 0.14 AC 55 6250 SF 0.14 AC 54 6250 SF 0.14 AC 53 6250 SF 0.14 AC 47 6250 SF 0.14 AC 48 6873 SF 0.16 AC 51 6588 SF 0.15 AC 50 6250 SF 0.14 AC 60 6250 SF 0.14 AC 62 8136 SF 0.19 AC 12 6834 SF 0.16 AC 11 6394 SF 0.15 AC 10 7086 SF 0.16 AC 9 6508 SF 0.15 AC 8 7899 SF 0.18 AC 61 7196 SF 0.17 AC 7 8755 SF 0.20 AC 6 8290 SF 0.19 AC50'125'50'50'125'50'50'125'50'50'125'50'76'125'50'5'19'125'50'40'39'125'50'125'33'15'125'34'50'125'50'125'21'29'125'39'125'50'50'100'40'59'45'130'50' 45'130'44' 50'130'50' 44'130'44' 44'50'130'5'45' 44'130'58' 30'130'69' 18'130' 60' 50' 21' 1 2 5 ' 17' 42'127'18'1 2 5 ' 44'45'1 2 5 ' 49' 44' 1 2 7 ' 44' 44' 1 3 3 ' 50' 44' 1 4 2 ' 45' 50'17'30' 1 3 2 ' 52' 34' 60' 1 6 2 ' 9'45' 50' 50' 1 4 1 ' 59'3' 1 0 0 ' 52' 62' 50'125'5'120'57' 18'105'25'48' 48'130'46' 44'130'44' 50'130'50' 44'130'44' 31'130'30'27' 43'130'55' 43'130'57' 5' 8'130' 57' 66'105'60'8'26' 8' 50'147'50'147'50'147'50' 44'147'44' 50'151'37' 13' 44'155'44' 50'161'50' 40'175'75'163'10'151'59' 33' 50'50'116'82'34'125'56'46'54'39' 125'50'1 0 0 '99' 33' 1 7 8 ' 22' 44' 9 5 '131' 39' 86'47'105'141'18'255'21' 44'44'18'254'55' 44'253'14'30' 50'252'51' 50'251'43' 81'168'34'163'50' 49'158'44' 44' 54'153'54'148'48' 48'142'50' 50' 65'55'86'40' 125' 125'50'125'50'125'50'50'47'50'54'63'50'125' WETLANDS WETLANDS WETLANDS SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY RETAINING WALL DESIGNED BY OTHERS SCM #1 SCM #2 SCM #3 EXISTING ACCESS EASEMENT MAIL KIOSK 20' DRAINAGE EASEMENT 20' DRAINAGE ACCESS & MAINTENANCE EASEMENT 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENTFIRE LANE60' ROW SOUTH S T R E E T 60' ROW MAIN STREET60' ROWJOHNSON STREET 60' ROWBREWER AVENUE60' ROW30' PUBLIC UTILITY EASEMENT 5' SIDEWALK (TYP) 30" VALLEY CURB & GUTTER (TYP) DRAINAGE ACCESS & MAINTENANCE EASEMENT DRAINAGE ACCESS & MAINTENANCE EASEMENT 20' DRAINAGE ACCESS & MAINTENANCE EASEMENT R25'R25'FIRE LANE60' ROWCONDUCTOR COURT 60' ROW CON D U C T O R C O U R T 60' R O W S52°57'29"W 388.37' R=250' L=164 . 8 6' S15° 1 0'2 6" W 271.5 1' S74°49'34"E 20.00' S69° 5 0 ' 5 3 " W 360.6 8 ' R=250' L=168.30' S31°1 6' 3 2 " W 7.66' R=380' L=143.80' S52°57'29"W 109.45'N37°02'31"W224.16'R=250'L=38.26'N28°16'21"W129.14'R=250'L=107.62'N52°56'13"W251.67'R=200'L=44.82'R=200'L=44.82'OPEN SPACE AREA #5 17,094 SF 0.39 ACFIRE LANE40' ROW N52°56'13"W 124.05' R35' R35' R25' R25' R25' R25' R20' R20' OPEN SPACE AREA #2 46,107 SF 1.06 AC OPEN SPACE AREA #3 200,821 SF 4.61 AC OPEN SPACE AREA #4 24,513 SF 0.56 AC OPEN SPACE AREA #6 2,665 SF 0.06 AC TEMPORARY CONSTRUCTION EASEMENT TEMPORARY CONSTRUCTION EASEMENT TEMPORARY CONSTRUCTION EASEMENT 20' DRAINAGE EASEMENT SITE PLANC2.0 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C2.0-SITE.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 0 SCALE 1"=80' 160'80'NAD 83WETLANDS OPEN SPACE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGENDOPEN SPACE DATA TOTAL AREA PROPOSED USE CURRENT ZONING PROPOSED ZONING TOTAL LOTS PROPOSED MINIMUM LOT SIZE AVERAGE LOT SIZE LINEAR FEET IN PUBLIC STREET PROPOSED DENSITY OPEN SPACE PROVIDED FEMA MAP # MOORE COUNTY PINs 26.47 AC SINGLE FAMILY RESIDENTIAL R-1 R-1 70 5,490 SF 7,455 SF 2,600 LF 0.38 UNITS/AC 11.03 AC 3710951400J DATED 10/17/06 951411662337 SITE DATA OPEN SPACE AREA #1 189,468 SF 4.35 AC 16.43% OPEN SPACE AREA #2 46,107 SF 1.06 AC 4.00% OPEN SPACE AREA #3 200,821 SF 4.61 AC 17.42% OPEN SPACE AREA #4 24,513 SF 0.56 AC 2.13% OPEN SPACE AREA #5 17,094 SF 0.39 AC 1.48% OPEN SPACE AREA #6 2,665 SF 0.06 AC 0.23% TOTAL 480,668 SF 11.03 AC 41.69% GENERAL NOTES 1.BOUNDARY INFORMATION TAKEN FROM CHANDLER LAND SURVEYING ON 03/30/2017. 2.TOPOGRAPHIC INFORMATION TAKEN FROM CHANDLER LAND SURVEYING AND MOORE COUNTY GIS. 3.CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES AND SHALL BE RESPONSIBLE FOR ANY DAMAGE RESULTING FROM HIS ACTIVITIES. CALL UTILITY LOCATOR SERVICE AT LEAST 48 HOURS PRIOR TO DIGGING. 4.ALL CONSTRUCTION SHALL CONFORM TO TOWN OF VASS AND NORTH CAROLINA STATE SPECIFICATIONS. 5.ALL UTILITIES SHALL BE LOCATED UNDERGROUND. 6.RAMPS AND CURBS SHOULD BE IN ACCORDANCE WITH TOWN OF VASS STANDARDS FOR LOCAL STREETS. 7.STREET ADDRESSES SHALL BE ASSIGNED PRIOR TO LOT RECORDATION. 8.STREET NAMES SHALL BE APPROVED PRIOR TO PLAT RECORDATION. 9.SIGN PERMITS SHALL BE REQUIRED FOR ANY ENTRANCE SIGNAGE. PERMITS WILL BE REQUIRED PRIOR TO FABRICATION OR INSTALLATION OF SIGNS. SIGNAGE WILL BE RESTRICTED TO AN ON-SITE LOCATION. 10.AN EROSION CONTROL PLAN SHALL BE APPROVED BY TOWN OF VASS PRIOR TO ANY GRADING ON THIS SITE. 11.THE DEVELOPER IS RESPONSIBLE FOR COORDINATION AND INSTALLATION OF ALL UTILITIES, INCLUDING STREET LIGHTING. 12.NO REVISIONS MAY BE MADE WITHOUT PERMISSION FROM THE PERMIT ISSUING AUTHORITY. 13.CONSTRUCTION DRAWINGS SHALL BE SUBMITTED AND APPROVED BY THE TOWN OF VASS AND NCDOT PRIOR TO CONSTRUCTION. 14.RESTRICTIVE COVENANTS SHALL BE APPROVED AND RECORDED PRIOR TO RECORDING OF FINAL PLAT. 15.A HOME OWNER'S ASSOCIATION FOR OWNERSHIP AND MANAGEMENT OF OPEN SPACE, BUFFERS AND RESTRICTIVE COVENANTS MUST BE SUBMITTED FOR REVIEW WITH THE FIRST FINAL PLAT. 16.ALL OPEN SPACE SHALL BE PRIVATE COMMON OPEN SPACE CONTROLLED BY THE HOMEOWNER'S ASSOCIATION (HOA). 17.THE TOWN WILL BE RESPONSIBLE FOR PAYMENT OF THE MONTHLY COSTS FOR PUBLIC STREET LIGHTING AND THE DEVELOPER WILL BE RESPONSIBLE FOR ALL INITIAL FEES CHARGED WITH THE LIGHT INSTALLATION. ALL INSTALLATION FEES ARE REQUIRED TO BE PAID UP FRONT AT THE TIME OF INSTALLATION. 18.CONTRACTOR TO ENSURE ACCESS EASEMENTS AND ASSOCIATED STREETS ARE FULLY MAINTAINED FOR REASONABLE ACCESS BY MAINTENANCE PERSONNEL. SANITARY SEWER SCHEDULE STRUCTURE UP EXMH 1 MH 1 MH 2 MH 3 MH 4 MH 5 MH 6 MH 7 MH 8 MH 9 MH 10 MH 11 MH 12 MH 13 MH 14 MH 15 HEIGHT 5.40' 6.08' 6.21' 6.86' 7.50' 8.49' 10.45' 10.68' 9.00' 11.00' 9.36' 11.36' 10.67' 6.11' 6.49' 9.00' RIM 306.04 307.48 308.18 310.57 313.69 320.58 326.58 327.85 326.75 332.94 307.86 311.36 311.22 308.35 309.48 318.01 INV IN 300.64' (8" DIP) MH 1 301.60' (8" DIP) MH 2 302.17' (8" DIP) MH 3 303.91' (8" PVC) MH 4 306.39' (8" PVC) MH 5 312.28' (8" PVC) MH 6 316.33' (8" PVC) MH 7 317.37' (8" PVC) MH 8 317.95' (8" DIP) MH 9 298.50' (8" PVC) MH 11 300.20' (8" PVC) MH 12 300.75' (8" PVC) MH 13 302.44' (8" DIP) MH 14 303.20' (8" DIP) MH 15 INV OUT 301.40' (8" DIP) 301.97' (8" DIP) 303.71' (8" DIP) 306.19' (8" PVC) 312.08' (8" PVC) 316.13' (8" PVC) 317.17' (8" PVC) 317.75' (8" PVC) 321.94' (8" DIP) 300.00' (8" PVC) 300.55' (8" PVC) 302.24' (8" PVC) 303.00' (8" DIP) 309.01' (8" DIP) OUTLET PIPE 152' @ 0.50% 74' @ 0.50% 307' @ 0.50% 203' @ 1.12% 238' @ 2.39% 149' @ 2.57% 169' @ 0.50% 75' @ 0.50% 311' @ 1.28% 299' @ 0.50% 70' @ 0.50% 298' @ 0.50% 111' @ 0.50% 356' @ 1.63% STRUCTURE DOWN EXMH 1 MH 1 MH 2 MH 3 MH 4 MH 5 MH 6 MH 7 MH 8 MH 10 MH 11 MH 12 MH 13 MH 14 SANSANWWWWS S SAN SAN W W S WWW1819202122 31 32 33 35 40 58 65 66 68 63 67 16 15 14 444142 64 17 13 3 5 4 1 70 2 69 23 29 34 36 30 37 38 28 26 24 27 25 8 43 49 46 45 52 59 39 47 48 51 56 55 54 53 57 60 62 50 12 11 10 9 61 7 6 SCM #1 SCM #2 SCM #3 SS S S S S SSSSSSS S SAN SAN SAN SAN SANSANSANSANSAN SSSANSANSAN 6''W6''W6''W6''W6''W6' 'W6' 'W6' 'W 6''W 6''W 6''W 6''W 6''W 6''W 6''W6''W6''W6''W6''W6''W 6''W 6''W 6''W 6''W 6''W6''W6''W WETLANDS WETLANDS WETLANDS SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY WALL DESIGNED BY OTHERS EXISTING ACCESS EASEMENT MAIL KIOSK 20' DRAINAGE EASEMENT 20' DRAINAGE ACCESS & MAINTENANCE EASEMENT 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENT 30' PUBLIC UTILITY EASEMENT DRAINAGE ACCESS & MAINTENANCE EASEMENT DRAINAGE ACCESS & MAINTENANCE EASEMENT 20' DRAINAGE ACCESS & MAINTENANCE EASEMENT EXMH 1 RIM: 306.04' INV IN (SE): 300.64' EX. INV IN (NE): 300.54' EX. INV OUT (SW): 300.44' EXMH 3 RIM: 308.60' INV IN (SE): 298.40' INV OUT (NW): 298.30' EXMH 2 RIM: 303.55' INV IN (SE): 297.25' INV OUT (NW): 297.20' EXISTING 6" CAST IRON WATER MAIN EXISTING 6" CAST IRON WATER MAIN EXISTING 1" CAST IRON WATER MAIN EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT MH 3 MH 12 MH 13 MH 14 MH 15 MH 5 MH 9 MH 8 MH 7 MH 6 MH 4 MH 2 MH 1 MH 11 8" PVC 8" DIP 8" DIP 8" DIP 8" PVC 8" PVC 8" PVC 8" PVC 8" PVC 8" DIP 8" DIP 8" DIP 8" PVC 8" PVC FIRE LANESOUTH S T R E E T 60' ROW MAIN STREET60' ROWJOHNSON STREET 60' ROWBREWER AVENUE60' ROWCONDUCTOR COURT CON D U C T O R C O U R T FIRE HYDRANT ASSEMBLY (TYP) 6" C900 W/L 6" C900 W/L 6" C900 W/L TEMPORARY BLOWOFF ASSEMBLY FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) CONNECT TO EXISTING 6" WATERMAIN WITH TAPPING SLEEVE & GV 45° BEND 22.5° BEND 6"X6" TEE 6" GV (3) CONNECT TO EXISTING 6" WATERMAIN WITH TAPPING SLEEVE & GV OPEN CUT AT WATERMAIN CROSSING MH 10 RIM: 307.86' INV IN (E): 298.50' INV IN (SE): 298.31' INV OUT (NW): 298.01' CONNECT TO EXISTING SEWERMAIN WITH DOGHOUSE MANHOLE SANITARY LATERAL (TYP) WATER METER (TYP) SANITARY LATERAL (TYP) WATER METER (TYP) 20' DRAINAGE EASEMENT JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C3.0-UTIL.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 UTILITY PLANC3.0 0 SCALE 1"=80' 160'80'NAD 83WETLANDS OPEN SPACE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND 8''W UTILITY LEGEND PROPOSED SEWER LINE PROPOSED FORCE MAIN PROPOSED WATER LINE WATER LINE TEE FIRE HYDRANT WATER METER REDUCER GATE VALVE. BLOWOFF ASSEMBLY FM SAN TOTAL GRAVITY SEWER: 2,815 LF 8" PVC:1,503 LF 8" DIP:1,312 LF TOTAL WATERMAIN: 2,779 LF 6" C900: 2,779 LF 4" SEWER SERVICES:70 3/4" WATER SERVICES:70 5/8" WATER METERS:70 FIRE HYDRANTS:7 UTILITY QUANTITIES UTILITY NOTES 1.TOWN OF VASS IS TO BE NOTIFIED 48 HOURS BEFORE CONSTRUCTION IS TO BEGIN. 2.TOWN OF VASS IS TO BE NOTIFIED 48 HOURS BEFORE ANY CONSTRUCTION IS TO BE COVERED. 3.ALL SERVICE PIPES UNDER ROADS OR DRIVEWAYS SHALL BE SLEEVED WITH SCH40 PVC A MINIMUM 1' OUTSIDE OF PAVEMENT EDGE. 4.INSTALL WATER MAINS WITH A COVER OF NO LESS THAN 3-FT. INSTALL WATER SERVICES WITH NO LESS THAN 18-IN OF COVER TO SUBGRADE. 5.THE CONTRACTOR SHALL VERIFY THE TYPE, SIZE, DEPTH, MATERIAL, AND LOCATION OF ALL UTILITIES PRIOR TO BEGINNING CONSTRUCTION. 6.THE CONTRACTOR SHALL NOT INSTALL ANY WATER SERVICES UNTIL ALL LOT LINES ARE FINALIZED BY COUNTY ENVIRONMENTAL HEALTH AND INSTRUCTED TO DO SO BY THE ENGINEER. 7.THE CONTRACTOR SHALL MINIMIZE THE PLACEMENT OF EXCAVATED MATERIAL ON THE ROADWAY. IF EXCAVATED MATERIAL MUST BE PLACED ON THE ROADWAY, THE CONTRACTOR SHALL FIRST COVER THE ROAD WITH SAND OR SCREENINGS. 8.COORDINATE AND SCHEDULE INSTALLATION OF ALL UTILITIES WITH OTHER PRIME CONTRACTORS, UTILITY COMPANIES AND OTHER TRADES INCLUDING BUT NOT LIMITED TO: NATURAL GAS, ELECTRICITY, TELEPHONE AND CATV. 9.THE CONTRACTOR SHALL COMPLY WITH THE APPROVED NCDOT ENCROACHMENT AGREEMENT. 10.ALL CONSTRUCTION METHODS SHALL COMPLY WITH ALL APPLICABLE OSHA REQUIREMENTS. 11.BACTERIOLOGICAL SAMPLE RESULTS OLDER THAN THIRTY (30) DAYS FROM THE DATE OF THE PROJECT ACCEPTANCE WILL NOT BE ACCEPTABLE AND BACTERIOLOGICAL TESTING MUST BE REPEATED. 12.CONTRACTOR SHALL PHASE DEMOLITION AND NEW CONSTRUCTION TO ENSURE UNINTERRUPTED ACCESS AND UTILITY SERVICE TO ADJACENT FACILITIES. COORDINATE SHORT-TERM, OFF-HOUR, TEMPORARY SHUT-DOWNS WITH THE COUNTY. 13.INSTALL ONE (1) JOINT OF DUCTILE IRON PIPE (DIP) UNDER ALL STORM DRAIN CROSSINGS. 14.WATER SERVICE PIPE SHALL BE POLYETHYLENE TUBING RATED FOR 200 PSI. WHERE WATER SERVICES ARE "PAIRED", A SINGLE 1" SERVICE LINE MAY BE PROVIDED WITH A BRONZE WYE. WHERE SERVICE LINES CROSS UNDER PAVEMENT AND ARE INSTALLED BY OPEN CUT, A 2" SCHEDULE 40 PVC SLEEVE SHALL BE PROVIDED THE LENGTH OF THE ROAD. 15.GATE VALVE LOCATIONS ARE APPROXIMATE DUE TO GRAPHICAL CONSTRAINTS. ACTUAL LOCATION SHOULD BE IMMEDIATELY ADJACENT TO TEES (WHERE APPLICABLE). 16.BLOW OFF ASSEMBLY SHALL BE INSTALLED AT THE PROPERTY LINE ON PROPERTY CORNER. 17.CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES DURING CONSTRUCTION AND REPAIRS TO DAMAGED UTILITIES (CHARTED OR UNCHARTED) WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 18.THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY REQUIRED DEVIATIONS FROM THE DESIGN PLAN. 19.THE CONTRACTOR SHALL PROVIDE ENGINEER WITH AS BUILT SURVEYS OF THE UTILITIES ONCE UTILITY CONSTRUCTION IS COMPLETE. 20.THE CONTRACTOR SHALL INSTALL PROPER THRUST BLOCKING AT ALL WATER MAIN BENDS WHETHER SHOWN ON THE DESIGN PLAN OR NOT. 21.ALL REDUCERS ADJACENT TO TEES SHALL BE RODDED TO THE TEE. 1819202122 31 32 33 35 40 58 65 66 68 63 67 16 15 14 444142 64 17 13 3 5 4 1 70 2 69 23 29 34 36 30 37 38 28 26 24 27 25 8 43 49 46 45 52 59 39 47 48 51 56 55 54 53 57 60 62 50 12 11 10 9 61 7 6 WETLANDS WETLANDS WETLANDS SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY WALL DESIGNED BY OTHERS EXISTING ACCESS EASEMENT MAIL KIOSK 20' DRAINAGE EASEMENT 20' DRAINAGE ACCESS & MAINTENANCE EASEMENT 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENT 30' PUBLIC UTILITY EASEMENT DRAINAGE ACCESS & MAINTENANCE EASEMENT DRAINAGE ACCESS & MAINTENANCE EASEMENT 20' DRAINAGE EASEMENT FIRE LANESOUTH S T R E E T 60' ROW MAIN STREET60' ROWJOHNSON STREET 60' ROWBREWER AVENUE60' ROWCONDUCTOR COURT CON D U C T O R C O U R T PAD 334.56' PAD 332.34' PAD 330.79' PAD 329.55' PAD 329.00' PAD 329.10' TW 335.31'TW 331.72' TW 322.70' TW 327.46' BW 333.19' BW 327.97' BW 324.06' BW 320.73'336335334333332331330329328 327 3 2 7 32 8 335330325320315 310305 300300295 300305300 300305 305 3103 1 5 320325330 335340PAD 336.05' PAD 333.44' PAD 331.38' PAD 329.93' PAD 329.06' PAD 328.62' PAD 328.65' DI 105 CB 104 DI 106 CB 102 CB 101 FES 100 CB 103 15" RCP30" RCP30" RCP 24" RCP 24" RCP18" RCP SCM #1 RISER SCM #1 FES SCM #3 RISER SCM #3 FES SCM #2 RISER SCM #2 FES 18" RCP 24" RCP 24" RCP SCM #2 (SEE SCM DETAIL SHEET) SCM #1 (SEE SCM DETAIL SHEET) SCM #3 (SEE SCM DETAIL SHEET) NAG C350 OR EQUIVALENT LINER NAG C350 OR EQUIVALENT LINER NAG C350 OR EQUIVALENT LINER 7.5'x15'x18" CLASS B RIPRAP D50 = 8" DI 212 CB 215 CB 216 DI 211 CB 213 CB 214 DI 209 CB 207 CB 208 DI 210 CB 205 CB 204 CB 206 CB 202 CB 203 DI 201 FES 200 15" RCP 36" RCP 36" RCP 24" RCP 15" RCP 15" RCP 15" RCP 15" RCP 15" RCP 30" RCP 36" RCP 36" RCP 15" RCP 15" RCP15" RCP 18" RCP CB 308 CB 309 CB 306 CB 307 CB 305 CB 304 CB 303 CB 302 CB 301 FES 300 DI 312 CB 311 CB 310 15" RCP 18" RCP 24" RCP 36" RCP 18" RCP 15" RCP 18" RCP 15" RCP CB 401 CB 402 CB 403 CB 404 CB 405 FES 406 FES 400 36" RCP36" RCP 15" RCP 15" RCP 36" RCP 36" RCP 325326327328324323322321320319318317316315314313312311310309309 310 3 1 1 31 9 31 8 31 7 31 6 3 14313 3113 1 0 3 0 9 3 0 83083 0 8 3 0 7306 PAD 329.31'PAD 329.98' PAD 329.53'PAD 330.30'PAD 330.25'PAD 329.76'PAD 328.60'PAD 327.10' PAD 325.14' PAD 323.38' PAD 321.38' PAD 319.62' PAD 317.62' PAD 316.05' PAD 314.96' PAD 314.19' PAD 313.32' PAD 312.55'PAD 311.12' PAD 310.48' PAD 311.06' PAD 311.50' PAD 312.00' PAD 311.96' PAD 315.14' PAD 313.37' PAD 312.85' PAD 311.91' PAD 311.41' PAD 310.97' PAD 310.47' PAD 310.03' PAD 310.45' PAD 311.08' PAD 311.70' PAD 312.52' PAD 313.29' PAD 314.16' PAD 314.93' PAD 315.99'PAD 320.87' PAD 319.27' PAD 317.41' PAD 320.89' PAD 320.02' PAD 315.95' PAD 315.30' PAD 314.55' PAD 313.76' PAD 312.61' PAD 311.51' PAD 310.76' PAD 310.01' PAD 309.97' PAD 309.20' PAD 309.51' PAD 309.44' 9'x18'x18" CLASS B RIPRAP D50 = 8" 6'x12'x18" CLASS B RIPRAP D50 = 8" 9'x18'x18" CLASS B RIPRAP D50 = 8" 9'x18'x18" CLASS B RIPRAP D50 = 8" 6'x12'x18" CLASS B RIPRAP D50 = 8" 4.5'x6'x12" CLASS A RIPRAP D50 = 4" 15" RCP 15" RCP 15" RCP TOC - HP 312.04'300300300300300300320320TEMPORARY CONSTRUCTION EASEMENT TEMPORARY CONSTRUCTION EASEMENT TEMPORARY CONSTRUCTION EASEMENT 20' DRAINAGE EASEMENT JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C4.0-GRAD.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 GRADING & DRAINAGE PLANC4.0 0 SCALE 1"=80' 160'80'NAD 83WETLANDS OPEN SPACE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND GRADING AND DRAINAGE NOTES 1.ANY GRADING BEYOND THE DENUDED LIMITS INDICATED ON THE CONSTRUCTION DOCUMENTS IS A VIOLATION AND IS SUBJECT TO A FINE. 2.GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION AND IS SUBJECT TO A FINE. 3.ALL FINAL STREET GRADES AT INTERSECTIONS SHALL BE COORDINATED WITH INSPECTOR. 4.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ON ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNER(S). 5.THE CONTRACTOR SHALL MAINTAIN EACH STREAM, CREEK, OR BACKWASH CHANNEL IN AN UNOBSTRUCTED CONDITION AND SHALL REMOVE FROM THESE AREAS ALL DEBRIS, LOGS, TIMBER, TRASH, JUNK AND OTHER ACCUMULATIONS. 6.FOR SLOPE CONSTRUCTION 3:1 AND STEEPER THE CONTRACTOR SHALL COORDINATE WITH A GEOTECHNICAL ENGINEER ON THE SUITABILITY OF SOILS PLANNED FOR THESE SLOPES AND FOLLOW RECOMMENDATIONS SET FORTH BY THE GEOTECHNICAL ENGINEER FOR SLOPE CONSTRUCTION. ALL SLOPES SHOULD BE TRACKED TOP TO BOTTOM AND STABILIZED WITH NORTH AMERICAN GREEN S150, OR APPROVED OTHER, STAKED TO MANUFACTURER'S RECOMMENDATIONS. TOP SOIL PLACEMENT ON SLOPES SHALL BE INSTALLED IN A BENCHED PATTERN. 7."AS-BUILT" DRAWINGS AND PLANS OF THE STORM DRAINAGE SYSTEM, INCLUDING DESIGNED DITCHES, MUST BE SUBMITTED PRIOR TO FINAL INSPECTION TO THE CITY/COUNTY ENGINEERING DEPARTMENT IN ACCORDANCE WITH COUNTY ORDINANCE. 8.ALL DISTURBED AREAS MUST BE SEEDED AND MULCHED WITHIN 14 CALENDAR DAYS. 9.SLOPES SHALL BE GRADED NO STEEPER THAN 2:1. FILL SLOPES GREATER THAN 10' REQUIRE ADEQUATE TERRACING. SEE DETAIL. 10.A GRADING PLAN MUST BE SUBMITTED FOR ANY LOT GRADING EXCEEDING ONE ACRE THAT WAS NOT PREVIOUSLY APPROVED. STORM DRAINAGE SCHEDULE STRUCTURE UP CB 101 CB 102 CB 103 CB 104 DI 105 DI 106 FES 100 HEIGHT 5.85' 4.45' 6.12' 5.77' 5.26' 3.28' ???' TOP 326.49 326.49 327.38 327.72 327.99 327.00 322.29 INV IN 320.74' (30" RCP) CB 103 321.89' (15" RCP) CB 102 321.76' (24" RCP) CB 104 322.05' (24" RCP) DI 105 323.23' (18" RCP) DI 106 319.50' (30" RCP) CB 101 INV OUT 320.64' (30" RCP) 322.04' (15" RCP) 321.26' (30" RCP) 321.95' (24" RCP) 322.73' (24" RCP) 323.72' (18" RCP) OUTLET PIPE 216' @ 0.53% 30' @ 0.50% 104' @ 0.50% 38' @ 0.50% 137' @ 0.50% 99' @ 0.50% STRUCTURE DOWN FES 100 CB 101 CB 101 CB 103 CB 104 DI 105 STORM DRAINAGE SCHEDULE STRUCTURE UP CB 202 CB 203 CB 204 CB 205 CB 206 CB 207 CB 208 CB 213 CB 214 CB 215 CB 216 DI 201 DI 209 DI 210 DI 211 DI 212 FES 200 HEIGHT 9.68' 4.00' 4.40' 4.00' 9.58' 10.31' 9.60' 4.40' 4.00' 4.40' 4.00' 4.83' 4.42' 3.21' 5.00' 5.00' ???' TOP 308.48 308.47 309.37 309.37 308.74 309.95 309.94 314.42 314.42 323.63 323.63 302.10 308.01 308.00 315.44 325.76 299.33 INV IN 298.90' (36" RCP) CB 206 303.88' (15" RCP) CB 204 304.17' (15" RCP) CB 203 305.07' (15" RCP) CB 205 299.26' (36" RCP) CB 207 301.39' (15" RCP) CB 213 300.04' (30" RCP) CB 208 300.84' (24" RCP) DI 209 310.12' (15" RCP) CB 215 310.12' (15" RCP) CB 214 319.33' (15" RCP) CB 216 297.27' (36" RCP) CB 202 304.34' (15" RCP) DI 211 304.09' (18" RCP) DI 210 310.54' (15" RCP) DI 212 296.00' (36" RCP) DI 201 INV OUT 298.80' (36" RCP) 304.47' (15" RCP) 304.97' (15" RCP) 305.37' (15" RCP) 299.16' (36" RCP) 299.64' (36" RCP) 300.34' (30" RCP) 310.02' (15" RCP) 310.42' (15" RCP) 319.23' (15" RCP) 319.63' (15" RCP) 297.17' (36" RCP) 303.59' (24" RCP) 305.42' (18" RCP) 310.44' (15" RCP) 320.76' (15" RCP) OUTLET PIPE 153' @ 1.00% 30' @ 1.00% 109' @ 1.00% 30' @ 1.00% 51' @ 0.51% 77' @ 0.49% 30' @ 1.00% 241' @ 3.58% 30' @ 1.00% 234' @ 3.90% 30' @ 1.00% 112' @ 1.05% 125' @ 2.20% 137' @ 0.97% 286' @ 2.13% 243' @ 4.20% STRUCTURE DOWN DI 201 CB 202 CB 202 CB 204 CB 202 CB 206 CB 207 CB 207 CB 213 CB 213 CB 215 FES 200 CB 208 DI 209 DI 209 DI 211 STORM DRAINAGE SCHEDULE STRUCTURE UP CB 301 CB 302 CB 303 CB 304 CB 305 CB 306 CB 307 CB 308 CB 309 CB 310 CB 311 DI 312 FES 300 HEIGHT 9.00' 7.35' 3.99' 5.04' 4.00' 4.55' 4.00' 4.50' 4.09' 4.40' 4.00' 5.16' ???' TOP 307.84 307.84 307.85 310.56 310.57 312.14 312.14 313.63 313.62 315.72 315.72 318.33 301.33 INV IN 299.84' (24" RCP) CB 304 300.34' (18" RCP) CB 302 303.82' (15" RCP) CB 303 306.02' (18" RCP) CB 306 306.27' (15" RCP) CB 305 307.59' (18" RCP) CB 308 307.84' (15" RCP) CB 307 309.38' (15" RCP) CB 310 309.38' (15" RCP) CB 309 311.42' (15" RCP) CB 311 311.82' (15" RCP) DI 312 298.00' (36" RCP) CB 301 INV OUT 298.84' (36" RCP) 300.49' (18" RCP) 303.85' (15" RCP) 305.52' (24" RCP) 306.57' (15" RCP) 307.59' (18" RCP) 308.14' (15" RCP) 309.13' (18" RCP) 309.53' (15" RCP) 311.32' (15" RCP) 311.72' (15" RCP) 313.17' (15" RCP) OUTLET PIPE 167' @ 0.50% 30' @ 0.50% 7' @ 0.43% 205' @ 2.78% 30' @ 1.00% 100' @ 1.56% 30' @ 1.00% 99' @ 1.55% 30' @ 0.50% 112' @ 1.73% 30' @ 1.00% 135' @ 1.00% STRUCTURE DOWN FES 300 CB 301 CB 302 CB 301 CB 304 CB 304 CB 306 CB 306 CB 308 CB 308 CB 310 CB 311 STORM DRAINAGE SCHEDULE STRUCTURE UP CB 401 CB 402 CB 403 CB 404 CB 405 FES 400 FES 406 HEIGHT 10.23' 9.82' 8.66' 5.19' 4.00' ???' ???' TOP 307.97 307.96 307.45 306.59 306.59 299.83 305.33 INV IN 297.84' (36" RCP) CB 402 298.24' (36" RCP) CB 403 301.85' (36" RCP) FES 406 300.54' (15" RCP) CB 404 302.29' (15" RCP) CB 405 296.50' (36" RCP) CB 401 INV OUT 297.74' (36" RCP) 298.14' (36" RCP) 298.79' (36" RCP) 301.40' (15" RCP) 302.59' (15" RCP) 302.00' (36" RCP) OUTLET PIPE 155' @ 0.80% 30' @ 1.00% 55' @ 1.01% 86' @ 1.00% 30' @ 1.00% 15' @ 0.98% STRUCTURE DOWN FES 400 CB 401 CB 402 CB 403 CB 404 CB 403 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C4.0-GRAD.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 STORM DRAINAGE SCHEDULEC4.1 1819202122 31 32 33 35 40 58 65 66 68 63 67 16 15 14 444142 64 17 13 3 5 4 1 70 2 69 23 29 34 36 30 37 38 28 26 24 27 25 8 43 49 46 45 52 59 39 47 48 51 56 55 54 53 57 60 62 50 12 11 10 9 61 7 6FIRE LANESOUTH S T R E E T 60' ROW MAIN STREET60' ROWBREWER AVENUE60' ROWCONDUCTOR COURT 335330325320315 310305 300300295 300305300300305 305 305 3103 1 5 320325330 335340JOHNSON STREET 60' ROW CON D U C T O R C O U R T WETLANDS WETLANDS WETLANDS SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY RETAINING WALL DESIGNED BY OTHERS EXISTING ACCESS EASEMENT MAIL KIOSK 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENT 30' PUBLIC UTILITY EASEMENT NAG C350 OR EQUIVALENT LINER NAG C350 OR EQUIVALENT LINER NAG C350 OR EQUIVALENT LINER LIMITS OF DISTURBANCE ARMOR BASIN ENTRY SLOPES WITH NAG C350 OR RIPRAP CHECK DAM (TYP) INLET PROTECTION (TYP) 7.5'x15'x18" CLASS B RIPRAP D50 = 8" 9'x18'x18" CLASS B RIPRAP D50 = 8" 6'x12'x18" CLASS B RIPRAP D50 = 8" 9'x18'x18" CLASS B RIPRAP D50 = 8" 9'x18'x18" CLASS B RIPRAP D50 = 8" 6'x12'x18" CLASS B RIPRAP D50 = 8" 4.5'x6'x12" CLASS A RIPRAP D50 = 4" CHECK DAM (TYP) SILT FENCE OUTLET (TYP) POROUS BAFFLE (TYP) SEDIMENT BASIN #2 (SEE TABLE) SEDIMENT BASIN #1 (SEE SCM TABLE) SEDIMENT BASIN #3 (SEE TABLE) POROUS BAFFLE (TYP) POROUS BAFFLE (TYP) LIMITS OF DISTURBANCE TREE PROTECTION SILT FENCE (TYP) TREE PROTECTION SILT FENCE (TYP) 2" SKIMMER 1.5" ORIFICE 2.5" SKIMMER 2.0" ORIFICE 2" SKIMMER 1.5" ORIFICE DIVERSION DITCH #5 DIVERSION DITCH #4 DIVERSION DITCH #1 DIVERSION DITCH #2 DIVERSION DITCH #3 SILT FENCE OUTLET (TYP) SILT FENCE OUTLET (TYP) TREE PROTECTION SILT FENCE (TYP) TREE PROTECTION SILT FENCE (TYP) TREE PROTECTION SILT FENCE (TYP) ARMOR BASIN ENTRY SLOPES WITH NAG C350 OR RIPRAP ARMOR BASIN ENTRY SLOPES WITH NAG C350 OR RIPRAP CHECK DAM (TYP) INLET PROTECTION (TYP) INLET PROTECTION (TYP) HORSESHOE INLET PROTECTION LIMITS OF DISTURBANCE CONSTRUCTION ENTRANCE (TYP) CONSTRUCTION ENTRANCE (TYP) CONCRETE WASHOUT STATION CONCRETE WASHOUT STATION JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C5.0-EROS.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 SEDIMENTATION & EROSION CONTROL PLANC5.0 0 SCALE 1"=80' 160'80'NAD 83WETLANDS OPEN SPACE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND GENERAL NOTES SITE AREA DESCRIPTION STABILIZATION TIME FRAME STABILIZATION TIME FRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES AND SLOPES 7 DAYS NONE HIGH QUALITY WATER (HQW) ZONES 7 DAYS NONE SLOPES STEEPER THAN 3:1 7 DAYS IF SLOPES ARE 10' OR LESS IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ALLOWED SLOPES 3:1 OR FLATTER 14 DAYS 7 DAYS FOR SLOPES GREATER THAN 50 FEET IN LENGTH ANY OTHER AREAS WITH SLOPES FLATTER THAN 4:1 14 DAYS NONE (EXCEPT FOR PERIMETERS AND HQW ZONES) * "EXTENSIONS OF TIME MAY BE APPROVED BY THE PERMITTING AUTHORITY BASED ON WEATHER OR OTHER SITE-SPECIFIC CONDITIONS THAT MAKE COMPLIANCE IMPRACTICABLE." (SECTION II.B(2)(B) GROUND STABILIZATION 1.THE GRADING CONTRACTOR SHALL COMPLY WITH ALL STATE AND LOCAL CODES IN OBSERVING EROSION CONTROL MEASURES BOTH ON AND OFF-SITE. 2.THE GRADING CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL DEVICES AFTER EACH RAINFALL EVENT OR AS DIRECTED BY LOCAL AUTHORITIES OR THE ENGINEER. 3.THE GRADING CONTRACTOR SHALL BE RESPONSIBLE FOR OFF-SITE DISPOSAL OF ALL CLEARING AND GRADING WASTE MATERIALS GENERATED DURING HIS PHASE OF WORK AND FOR OBTAINING ALL APPLICABLE PERMITS FOR OFF-SITE STOCKPILES AND/OR WASTE AREAS. 4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING ANY TRACKED SOIL FROM ALL ADJACENT ROADWAYS THAT ARE IMPACTED BY CONSTRUCTION TRAFFIC. DISTURBED AREA = 18.00 ACRES STOCKPILE MAINTENANCE PLAN 1.SEEDING OR COVERING STOCKPILES WITH TARPS OR MULCH IS REQUIRED AND WILL REDUCE EROSION PROBLEMS. TARPS SHOULD BE KEYED IN AT THE TOP OF THE SLOPE TO KEEP WATER FROM RUNNING UNDERNEATH THE PLASTIC. 2.THE APPROVED PLAN SHALL PROVIDE FOR THE USE OF STAGED SEEDING AND MULCHING ON A CONTINUAL BASIS WHILE THE STOCKPILE IS IN USE. 3.ESTABLISH AND MAINTAIN A VEGETATIVE BUFFER AT THE TOE OF THE SLOPE (WHERE PRACTICAL). MAINTENANCE PLAN 1.A 25-FOOT TEMPORARY MAINTENANCE AND ACCESS EASEMENT SHALL BE SHOWN AROUND ALL PROPOSED STOCKPILES (EROSION CONTROL MEASURES SURROUNDING THE STOCKPILE SHALL BE SHOWN AT THE OUTER LIMIT OF THIS EASEMENT). 2.STOCKPILE FOOTPRINTS SHALL BE SETBACK A MINIMUM OF 25’ FROM ADJACENT PROPERTY LINES. 3.A NOTE SHALL BE PROVIDED ON THE APPROVED PLAN THAT STOCKPILE HEIGHT SHALL NOT EXCEED 35 FEET. 4.STOCKPILE SLOPES SHALL BE 2:1 OR FLATTER. 5.APPROVED BMPS SHALL BE SHOWN ON A PLAN TO CONTROL ANY POTENTIAL SEDIMENT LOSS FROM A STOCKPILE. 6.STOCKPILING MATERIALS ADJACENT TO A DITCH, DRAINAGEWAY, WATERCOURSE, WETLAND, STREAM BUFFER, OR OTHER BODY OF WATER SHALL BE AVOIDED UNLESS AN ALTERNATIVE LOCATION IS DEMONSTRATED TO BE UNAVAILABLE. 7.ANY CONCENTRATED FLOW LIKELY TO AFFECT THE STOCKPILE SHALL BE DIVERTED TO AN APPROVED BMP. 8.OFF-SITE SPOIL OR BORROW AREAS MUST BE IN COMPLIANCE WITH STATE REGULATIONS. ALL SPOIL AREAS OVER AN ACRE ARE REQUIRED TO HAVE AN APPROVED SEDIMENT CONTROL PLAN. STOCKPILE DESIGN CRITERIA 1.ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CHECKED FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF-PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN ALL MEASURES AS DESIGNED. 2.REMOVE SEDIMENT FROM SEDIMENT SKIMMER BASINS WHEN STORAGE CAPACITY HAS BEEN APPROXIMATELY 50% FILLED. CLEAN OR REPLACE GRAVEL FILTER WHEN THE SEDIMENT POOL NO LONGER DRAINS PROPERLY. 3.REMOVE SEDIMENT FROM BEHIND SILT FENCE WHEN DEPTH REACHES 6-INCHES AT THE FENCE. REPAIR SILT FENCE AS NECESSARY TO MAINTAIN A BARRIER. 4.ALL SEEDED AREAS SHALL BE FERTILIZED, RE-SEEDED AS NECESSARY, AND MULCHED ACCORDING TO PROJECT SPECS TO MAINTAIN A VIGOROUS, DENSE VEGETATIVE GROWTH. 5.MAINTAIN SILT/TREE PROTECTION FENCING THROUGHOUT DURATION OF CONSTRUCTION. 1.SCHEDULE A SITE MEETING WITH THE ENVIRONMENTAL ENGINEER/CONSULTANT TO DETERMINE IF A BASIN CAN BE REMOVED. INSTALL SILT FENCING OR OTHER TEMPORARY EROSION CONTROL MEASURES AS NEEDED PRIOR TO REMOVAL OF THE BASIN. 2.REMOVE BASIN(S) AND ASSOCIATED TEMPORARY DIVERSION DITCHES. IF CULVERT PIPES NEED TO BE EXTENDED, PERFORM THIS OPERATION AT THIS TIME. FINE GRADE AREA IN PREPARATION FOR SEEDING. 3.PERFORM SEEDBED PREPARATION, SEED, MULCH AND ASPHALT TACK ANY RESULTING BARE AREAS IMMEDIATELY. 4.INSTALL VELOCITY DISSIPATORS AND/OR LEVEL SPREADERS AS REQUIRED ON THE EROSION CONTROL PLAN. 5.WHEN SITE IS FULLY STABILIZED, CALL ENVIRONMENTAL ENGINEER/CONSULTANT FOR APPROVAL OF REMOVING REMAINING TEMPORARY EROSION CONTROL MEASURES AND ADVICE ON WHEN SITE CAN BE ISSUED A CERTIFICATE OF COMPLETION. BASIN REMOVAL SEQUENCE THE SEDIMENTATION POLLUTION CONTROL ACT WAS AMENDED IN 2006 TO REQUIRE THAT PERSONS RESPONSIBLE FOR LAND-DISTURBING ACTIVITIES INSPECT A PROJECT AFTER EACH PHASE OF THE PROJECT TO MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. RULES DETAILING THE DOCUMENTATION OF THESE INSPECTIONS TOOK EFFECT OCTOBER 1, 2010. THE SELF-INSPECTION PROGRAM IS SEPARATE FROM THE WEEKLY SELF-MONITORING PROGRAM OF THE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITIES. THE FOCUS OF THE SELF-INSPECTION REPORT IS THE INSTALLATION AND MAINTENANCE OF EROSION AND SEDIMENTATION CONTROL MEASURES ACCORDING TO THE APPROVED PLAN. THE INSPECTIONS SHOULD BE CONDUCTED AFTER EACH PHASE OF THE PROJECT, AND CONTINUED UNTIL PERMANENT GROUND COVER IS ESTABLISHED. THE SELF-INSPECTION REPORT FORM IS AVAILABLE AS AN EXCEL SPREADSHEET FROM THE LAND QUALITY WEB SITE, HTTP://PORTAL.NCDENR.ORG/WEB/LR/EROSION NCDENR SELF-INSPECTION PROGRAM EROSION CONTROL LEGEND LIMITS OF DISTURBANCE STANDARD GRAVEL INLET PROTECTION DIVERSION DITCH SILT FENCE OUTLET POROUS BAFFLES SKIMMER TREE PROTECTION SILT FENCE CHECK DAM SANSANSANSANWWWWS18 58 44 49 46 45 52 59 47 48 51 56 55 54 53 57 60 50 61 SOUTH STREET60' ROWCONDUCTOR COURT60' ROWSSSSSSSSANSANSANSANSAN SAN SAN SAN SAN SAN SAN 6''W 6''W 6''W 6''W 6''W 6''W 6''W 6''W 6''W6''W 6''W 6''W 6''W 6''W 6''W 6''W6''W6''W6''W6''W6''W6''W6''W6''WSFIRE LANE 60' ROW FIRE LANE 40' ROW FIRE LANE 60' ROW 9+59.05 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 19+94.5216+0017+0019+0020+00CB 404 15" RCP CB 405 15" RCP CB 403 36" RCP FES 406 FES 400 36" RCPCB 401 36" RCP CB 402 DI 312 CB 311 CB 310 CB 308 CB 309 CB 306 CB 307 CB 305 CB 304 CB 303 CB 302 CB 301 FES 300 15" RCP 18" RCP 24" RCP 36" RCP18" RCP 15" RCP 18" RCP 15" RCP15" RCP 15" RCP 15" RCP15" RCPCB 215 CB 216 CB 213 CB 214 15" RCP 15" RCP 15" RCP MH 6 MH 5 MH 15 MH 4 MH 3 MH 2MH 1 EXMH 1 8" PVC 8" PVC 8" PVC 8" PVC 8" DIP 8" DIP 8" DIP HORIZ SCALE: 1"=50' VERT SCALE: 1"=5' FIRE LANE PLAN & PROFILE 290 295 300 305 310 315 320 325 330 335 290 295 300 305 310 315 320 325 330 335 306.3304.9302.2302.0302.9304.2305.5307.4309.1311.3313.1314.4315.3316.2317.4318.5319.7321.5323.1324.9306.35306.70307.20307.70308.19308.19307.84308.20308.95309.70310.45311.21311.96312.71313.46314.21315.11316.74318.74320.189+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 20+50 80' VC K = 31.96 A.D. = 2.50% PVI ELEV = 307.60 PVI STA = 13+10 LOW POINT STA = 13+01.96 LOW POINT ELEV = 307.84 BVCS = 12+70.00BVCE = 308.00EVCS = 13+50.00EVCE = 308.2080' VC K = 32.01 A.D. = 2.50% PVI ELEV = 315.10 PVI STA = 18+08.92 LOW POINT STA = 17+68.92 LOW POINT ELEV = 314.50 BVCS = 17+68.92BVCE = 314.50EVCS = 18+48.92EVCE = 316.7060' VC K = 30.00 A.D. = -2.00% PVI ELEV = 308.45 PVI STA = 12+25 HIGH PT STA = 12+25.00 HIGH POINT ELEV = 308.30 BVCS = 11+95.00BVCE = 308.15EVCS = 12+55.00EVCE = 308.15-1.17% -2.00% 2.00% 1.50% 4.00% 1.00%-1.00%PVI STA = 10+00.00PVI ELEV = 306.35PVI STA = 10+06.76 PVI ELEV = 306.27 PVI STA = 19+77.02 PVI ELEV = 320.22 PVI STA = 19+64.52 PVI ELEV = 320.47 PVI STA = 19+22.02PVI ELEV = 319.62307 LF 8" DIP @ 0.50% MH 3 TOP 310.57 INV IN 303.91 (SS 4-3) INV OUT 303.71 (SS 3-2) 203 LF 8" PVC @ 1.12% MH 4 TOP 313.69 INV IN 306.39 (SS 5-4) INV OUT 306.19 (SS 4-3) 238 LF 8" PVC @ 2.39% MH 5 TOP 320.58 INV IN 312.28 (SS 6-5) INV OUT 312.08 (SS 5-4) MH 2 TOP 308.18 INV IN 302.17 (SS 3-2) INV OUT 301.97 (SS 2-1) 74 LF 8" DIP @ 0.50% MH 1 TOP 307.48 INV IN 301.60 (SS 2-1) INV OUT 301.40 (SS 1-EX) 152 LF 8" DIP @ 0.50% EXMH 1 TOP 306.04 INV IN 300.64 (SS 1-EX) CB 301 TOP 307.84 INV IN 299.84 (304-301) INV IN 300.34 (302-301) INV OUT 298.84 (301-300) 205 LF 24" RCP @ 2.78% CB 304 TOP 310.56 INV IN 306.02 (306-304) INV IN 306.27 (305-304) INV OUT 305.52 (304-301) 100 LF 18" RCP @ 1.56% 99 LF 18" RCP @ 1.55% CB 306 TOP 312.14 INV IN 307.59 (308-306) INV IN 307.84 (307-306) INV OUT 307.59 (306-304) CB 308 TOP 313.63 INV IN 309.38 (310-308) INV IN 309.38 (309-308) INV OUT 309.13 (308-306) CB 310 TOP 315.72 INV IN 311.42 (311-310) INV OUT 311.32 (310-308) CB 404 TOP 306.59 INV IN 302.29 (405-404) INV OUT 301.40 (404-403) 86 LF 15" RCP @ 1.00% CB 403 TOP 307.45 INV IN 301.85 (406-403) INV IN 300.54 (404-403) INV OUT 298.79 (403-402) 55 LF 36" RCP @ 1.01% CB 402 TOP 307.96 INV IN 298.24 (403-402) INV OUT 298.14 (402-401) 215-213 15" RCP 6" MIN. W/ CONCRETE CRADLE TEMPORARY BLOWOFF ASSEMBLY (TYP) 6" MIN. W/ CONCRETE CRADLE 6" MIN. W/ CONCRETE CRADLE FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) 6"X6" TEE (3) GVEXISTING GRADE PROPOSED GRADE 18" MIN. 18" MIN. 18" MIN. 18" MIN. 18" MIN. 6" C900 WATER MAIN 6" C900 WATER MAIN JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C6.1-PROF.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 FIRE LANE PLAN & PROFILEC6.1 SCALE 1"=50' 100'50'0 NAD 83PROFILE SCALE 0 0 50 5 6" C900 WATERLINE TEMPORARY BLOWOFF ASSEMBLY EXISTING 1" CAST IRON WATERMAIN SANITARY LATERAL (TYP) 6"x6" TEE (3) 6" GV 20' DRAINAGE EASEMENT 8''W UTILITY LEGEND PROPOSED SEWER LINE PROPOSED FORCE MAIN PROPOSED WATER LINE WATER LINE TEE FIRE HYDRANT WATER METER REDUCER GATE VALVE. BLOWOFF ASSEMBLY FM SAN WATERCOURSE BUFFER WETLANDS TREE SAVE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND MAIL KIOSK (TYP) SCM #3 FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) WATER METER (TYP) 6" C900 WATERLINE DRAINAGE EASEMENT 20' DRAINAGE EASEMENT EXISTING ACCESS EASEMENT 10' x 70' SDT EASEMENT 10' x 70' SDT EASEMENT WETLANDS HORIZ SCALE: 1"=50' VERT SCALE: 1"=5' CONDUCTOR COURT PLAN & PROFILE 305 310 315 320 325 330 335 340 345 350 305 310 315 320 325 330 335 340 345 350 338.0335.5334.0330.9328.7327.7328.1329.8330.3331.3332.5333.3332.8330.1328.4326.8324.9322.6319.8337.95335.00332.01329.60328.01327.25326.75326.50327.00327.75328.43328.45327.67326.07324.07322.07320.07318.07316.079+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 80' VC K = 32.00 A.D. = 2.50% PVI ELEV = 326.25 PVI STA = 13+50 LOW POINT STA = 13+42.00 LOW POINT ELEV = 326.49 BVCS = 13+10.00BVCE = 326.65EVCS = 13+90.00EVCE = 326.85150' VC K = 30.00 A.D. = 5.00% PVI ELEV = 328.10 PVI STA = 11+65 LOW POINT STA = 12+40.00 LOW POINT ELEV = 327.35 BVCS = 10+90.00BVCE = 332.60EVCS = 12+40.00EVCE = 327.35170' VC K = 30.91 A.D. = -5.50% PVI ELEV = 329.47 PVI STA = 15+65 HIGH PT STA = 15+26.36 HIGH POINT ELEV = 328.54 BVCS = 14+80.00BVCE = 328.20EVCS = 16+50.00EVCE = 326.07-5. 7 1 % 1.50% -6. 0 0 % -1.00% -4.0 0 %PVI STA = 10+00.00PVI ELEV = 337.95PVI STA = 10+14.65PVI ELEV = 337.12CB 104 TOP 327.72 INV IN 322.05 (105-104) INV OUT 321.95 (104-103)38 LF 24" RCP @ 0.50% CB 103 TOP 327.38 INV IN 321.76 (104-103) INV OUT 321.26 (103-101) 104 LF 30" RCP @ 0.50%CB 101 TOP 326.49 INV IN 320.74 (103-101) INV IN 321.89 (102-101) INV OUT 320.64 (101-100) MH 9 TOP 332.94 INV OUT 321.94 (SS 9-8) MH 8 TOP 326.75 INV IN 317.95 (SS 9-8) INV OUT 317.75 (SS 8-7) 75 LF 8" PVC @ 0.50% MH 7 TOP 327.85 INV IN 317.37 (SS 8-7) INV OUT 317.17 (SS 7-6) 169 LF 8" PVC @ 0.50% MH 6 TOP 326.58 INV IN 316.33 (SS 7-6) INV OUT 316.13 (SS 6-5) MH 5 TOP 320.58 INV IN 312.28 (SS 6-5) INV OUT 312.08 (SS 5-4) 149 L F 8" PV C @ 2.5 7 % CB 215 TOP 323.63 INV IN 319.33 (216-215) INV OUT 319.23 (215-213) 234 L F 15" R C P @ 3 . 9 0 % 6" MIN. W/ CONCRETE CRADLE 311 LF 8" DIP @ 1.28% 18" MIN. 18" MIN.CONNECT TO EXISTING 6" WATERLINE WITH TAPPING SLEEVE EXISTING GRADE PROPOSED GRADE 6"x6" TEE (3) 6" GV FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) 6" C900 WATER MAINWWWWWWWW 18 65 66 68 63 67 161514 44 64 1713 3 5 4 1 70 2 69 8 46 45 47 48 60 62 12 11 10 9 61 7 6MAIN STREET60' ROWCONDUCTOR COURT 60' ROWCON D U C T O R C O U R T 60' R O W 6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''WSSS S SSSANSANSANSANSANSANSANSANSANFIRE LANE60' ROW18+0019+0019+94.529+70. 6 0 10+0 0 11+0 0 12+0 0 13+0 0 14+00 15+00 16+00 17+00 19+00 DI 105 CB 104 CB 103 DI 106 CB 102 CB 101 15" RCP 30" RCP30" R C P 24" RCP 24" RCP18" RCP DI 312 CB 311 CB 310 15" RCP15" RCP 15" RCP DI 212 CB 215 CB 216 DI 211 CB 213 CB 214 15" RCP 15" RCP 15" RCP 15" RCP MH 9 MH 7 MH 8 MH 6 MH 5 MH 15 8" DIP 8" PVC 8" PVC 8" PVC 8" PVC JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C6.2-PROF.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 CONDUCTOR COURT (STA 10+00 TO 19+00) PLAN & PROFILEC6.2 SCALE 1"=50' 100'50'0 NAD 83PROFILE SCALE 0 0 50 5 FIRE HYDRANT ASSEMBLY (TYP) 6"x6" TEE (3) 6" GV SANITARY LATERAL (TYP) WATER METER (TYP) 8''W UTILITY LEGEND PROPOSED SEWER LINE PROPOSED FORCE MAIN PROPOSED WATER LINE WATER LINE TEE FIRE HYDRANT WATER METER REDUCER GATE VALVE. BLOWOFF ASSEMBLY FM SAN WATERCOURSE BUFFER WETLANDS TREE SAVE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) MAIL KIOSK (TYP) 6" C900 WATER MAIN 6" C900 WATER MAIN CONNECT TO EXISTING 6" WATERMAIN WITH TAPPING SLEEVE EXISTING 6" WATERMAIN DRAINAGE EASEMENT 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENT WALL DESIGN BY OTHERS 20' DRAINAGE EASEMENT 10' x 70' SDT EASEMENT 10' x 70' SDT EASEMENT 18 19 20 21 22 31 32 33 35 40 161514 44 4142 1713 23 29 34 36 30 37 38 28 26 24 27 25 43 46 45 39 47 60 12 61 CONDUCTOR COURT 60' ROW SANSANSANSANSAN6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''W6''WSSSSSSSANSANSANSANSANSANSANSANSANFIRE LANE60' ROW18+0019+0019+94.5226+6 0. 47 17+00 19+00 20+00 21+00 22+00 23+0 0 24+ 0 0 25+ 0 0 26+ 00 CB 215 CB 216 DI 211 CB 213 CB 214 CB 207 CB 208 CB 204 CB 205 CB 206 CB 202 CB 203 DI 209 DI 210 DI 201 15" RCP 36" RCP36" RCP24" RCP15" RCP 15" RCP 15" RCP 15" RCP 15" R C P 30" RCP 36" RCP 36" RCP 15" RCP 15" RCP 15" RCP 18" R C P CB 311 CB 310 15" RCP15" RCP 15" RCP MH 5 MH 15 MH 11 MH 12 MH 14 MH 13 8" PVC 8" DIP 8" DIP 8" PVC 8" PVC 8" PVC 8" PVC HORIZ SCALE: 1"=50' VERT SCALE: 1"=5' CONDUCTOR COURT PLAN & PROFILE 295 300 305 310 315 320 325 330 335 295 300 305 310 315 320 325 330 335 EXISTING GRADE PROPOSED GRADE FIRE HYDRANT ASSEMBLY (TYP)324.9322.6319.8318.0316.6314.6312.6311.1309.9308.6307.7307.0306.5307.0308.1309.0309.8309.9320.07318.07316.07314.27313.20312.32311.45310.57309.70308.85308.48308.72309.22309.72310.22310.72311.22311.7218+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 110' VC K = 40.00 A.D. = 2.75% PVI ELEV = 308.12 PVI STA = 22+90 LOW POINT STA = 23+04.98 LOW POINT ELEV = 308.47 BVCS = 22+35.00BVCE = 309.09EVCS = 23+45.00EVCE = 308.6770' VC K = 31.10 A.D. = 2.25% PVI ELEV = 314.07 PVI STA = 19+50 LOW POINT STA = 19+85.00 LOW POINT ELEV = 313.46 BVCS = 19+15.00BVCE = 315.47EVCS = 19+85.00EVCE = 313.46-1.75% 1.00%PVI STA = 26+61.39PVI ELEV = 311.84234 L F 15" R C P @ 3 . 9 0 % CB 213 TOP 314.42 INV IN 310.12 (215-213) INV IN 310.12 (214-213) INV OUT 310.02 (213-207)241 L F 15" R C P @ 3. 5 8 % CB 207 TOP 309.95 INV IN 301.39 (213-207) INV IN 300.04 (208-207) INV OUT 299.64 (207-206) 77 LF 36" RCP @ 0.49% CB 206 TOP 308.74 INV IN 299.26 (207-206) INV OUT 299.16 (206-202) 51 LF 36" RCP @ 0.51% CB 202 TOP 308.48 INV IN 298.90 (206-202) INV IN 303.88 (204-202) INV IN 304.17 (203-202) INV OUT 298.80 (202-201) 109 LF 15" RCP @ 1.00% CB 204 TOP 309.37 INV IN 305.07 (205-204) INV OUT 304.97 (204-202) MH 15 TOP 318.01 INV OUT 309.01 (SS 15-14) 356 LF 8" DIP @ 1.63% MH 14 TOP 309.48 INV IN 303.20 (SS 15-14) INV OUT 303.00 (SS 14-13) 111 LF 8" DIP @ 0.50% MH 13 TOP 308.35 INV IN 302.44 (SS 14-13) INV OUT 302.24 (SS 13-12) 298 LF 8" PVC @ 0.50% MH 12 TOP 311.22 INV IN 300.75 (SS 13-12) INV OUT 300.55 (SS 12-11) FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) 18" MIN. 18" MIN. 18" MIN. 6" MIN. W/ CONCRETE CRADLE 6" MIN. W/ CONCRETE CRADLE 6" C900 WATER MAIN JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C6.3-PROF.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 CONDUCTOR COURT (STA 18+00 TO 27+00) PLAN & PROFILEC6.3 SCALE 1"=50' 100'50'0 NAD 83PROFILE SCALE 0 0 50 5 SANITARY LATERAL (TYP) WATER METER (TYP) 8''W UTILITY LEGEND PROPOSED SEWER LINE PROPOSED FORCE MAIN PROPOSED WATER LINE WATER LINE TEE FIRE HYDRANT WATER METER REDUCER GATE VALVE. BLOWOFF ASSEMBLY FM SAN WATERCOURSE BUFFER WETLANDS TREE SAVE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) FIRE HYDRANT ASSEMBLY (TYP) RETAINING WALL DESIGN BY OTHERS 10' x 70' SDT EASEMENT 10' x 70' SDT EASEMENT 6" C900 WATERLINE 6" C900 WATER MAIN 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENT 20' DRAINAGE EASEMENT 30' PUBLIC UTILITY EASEMENT SITE BOUNDARY SANSANSANSANSANSSWWWWW31 32 33 29 34 30 28 SANSANSAN6''W6''W6''W6''W6''W6''W6''W6''W6''WSSS SANSANSANSANSANSAN9+5010+0011+00 12+00 13+00 14+00 8" PVCMH 11 MH 10 8" PVCMH 12 8" PVC BREWER AVENUE60' ROWHORIZ SCALE: 1"=50' VERT SCALE: 1"=5' SSWR OUTFALL A PROFILE PLAN & PROFILE 290 295 300 305 310 315 320 325 290 295 300 305 310 315 320 325 EXISTING GRADE 308.3309.8310.3309.2307.9307.5307.4307.8307.7306.0311.24311.22312.189+00 10+00 11+00 12+00 13+00 14+00 15+00 MH 12 TOP 311.22 INV IN 300.75 (SS 13-12) INV OUT 300.55 (SS 12-11) MH 11 TOP 311.36 INV IN 300.20 (SS 12-11) INV OUT 300.00 (SS 11-10) 70 LF 8" PVC @ 0.50% 299 LF 8" PVC @ 0.50% MH 10 TOP 307.86 INV IN 298.50 (SS 11-10) PROPOSED GRADE JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C6.4-PROF.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 SANITARY SEWER OUTFALL A PLAN & PROFILEC6.4 SCALE 1"=50' 100'50'0 NAD 83PROFILE SCALE 0 0 50 5 SITE BOUNDARY 6" C900 WATERLINE FIRE HYDRANT ASSEMBLY (TYP) EXISTING 6" CAST IRON WATERMAIN SANITARY LATERAL (TYP) WATER METER (TYP) 8''W UTILITY LEGEND PROPOSED SEWER LINE PROPOSED FORCE MAIN PROPOSED WATER LINE WATER LINE TEE FIRE HYDRANT WATER METER REDUCER GATE VALVE. BLOWOFF ASSEMBLY FM SAN WATERCOURSE BUFFER WETLANDS TREE SAVE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND 30' PUBLIC UTILITY EASEMENT CONNECT TO EXISTING 6" CAST IRON WATERMAIN WITH TAPPING SLEEVE & GV CONNECT TO EXISTING SEWERMAIN WITH DOGHOUSE MANHOLE SITE BOUNDARY EXMH 3 RIM: 308.60' INV IN (SE): 298.40' INV OUT (NW): 298.30' 65 320 318 319 321 321 322 322 323 323 320 319 318 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C7.1-SCM.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 SCM 1 DETAILSC7.1 0 SCALE 1"=20' 40'20' NAD 8 3 WETLANDS OPEN SPACE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND EMERGENCY SPILLWAY ELEVATION 3:1 SLOPE3:1 SLOPENOTE: INSTALL RUBBER GASKETS ON ALL PIPE JOINTS FOR WATERPROOFING1 YR ELEV: 319.14' 10 YR ELEV: 321.23' 100 YR ELEV: 322.35' ELEV: 323.00' ELEV: 322.00' SCM #1 - DRY DETENTION POND ANTI-VORTEX TRASH RACK BY PLASTIC SOLUTIONS OR EQUAL CREST OF RISER ELEVATION: 321.00' CONCRETE RISER CENTERLINE OF DAM INSTALL 4" PVC TEE WITH SCREW TYPE PLUG ONCE SKIMMER IS REMOVED AND POND NO LONGER OPERATES AS A TEMPORARY SEDIMENT BASIN BARREL INV. IN ELEVATION: 318.00' CONCRETE ANTI-FLOTATION BLOCK @ BASE ELEVATION SEE TABLE FOR DIMENSIONS 5'X5'X5" CONCRETE ANTI-SEEP COLLAR LOCATED SLIGHTLY DOWNSTREAM FROM CENTERLINE OF DAM (MINIMUM 2' FROM PIPE JOINT) BARREL INV. OUT ELEVATION: 317.64' RIPRAP OUTFALL PROTECTION END SECTION DAM WIDTH: 10' TOP OF DAM ELEVATION 18" RCP BARREL 30' EMERGENCY SPILLWAY ELEV: 322.00' REINFORCE WITH NAG C350 TOP OF DAM ELEV: 323.00' WIDTH: 10' 4'x4' RISER STRUCTURE TOP: 321.00' 8" ORIFICE @ 318.00' BARREL INV OUT: 318.00' 72 LF 18" RCP @ 0.50% 7.5'x15'x18" CLASS B RIPRAP INV: 319.00' NOTE: CROSS SECTION NOT TO SCALE SCALE: N.T.S. EMERGENCY SPILLWAY SECTION 2.5 1 2.5 1 TOP OF EMBANKMENT ELEV.: 323.00' PERMANENT SPILLWAY CREST ELEV.: 322.00' REINFORCE WITH NAG C350 30' INV: 317.64' 4.5'x6'x12" CLASS B RIPRAP 8" ORIFICE ELEVATION: 318.00' SCM SIDES AND WEIR SHALL HAVE MAXIMUM SLOPES OF 3:1 OR FLATTER DIMENSIONS SHOWN ARE AT WEIR ELEVATION OF BASIN. BASIN VOLUMES PROVIDED ARE BASED ON AVAILABLE VOLUME AT THE PRINCIPAL SPILLWAY. SCM NUMBER BASIN VOLUME TO SPILLWAY CREST (CF) EMERGENCY SPILLWAY LENGTH (FT) ANTI-FLOTATION BASE DIMENSIONS #1 34,678 30 5'x5'x1.5' THICK RISER 4'x4' 36" RCP 300 300 296 297 298 299 299 301 301 2 9 7298299 295 2 9 6 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C7.1-SCM.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 SCM 2 DETAILSC7.2 0 SCALE 1"=20' 40'20'NAD 8 3 WETLANDS OPEN SPACE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND SCM SIDES AND WEIR SHALL HAVE MAXIMUM SLOPES OF 3:1 OR FLATTER DIMENSIONS SHOWN ARE AT WEIR ELEVATION OF BASIN. BASIN VOLUMES PROVIDED ARE BASED ON AVAILABLE VOLUME AT THE PRINCIPAL SPILLWAY. EMERGENCY SPILLWAY ELEVATION 3:1 SLOPE3:1 SLOPENOTE: INSTALL RUBBER GASKETS ON ALL PIPE JOINTS FOR WATERPROOFING1 YR ELEV: 297.45' 10 YR ELEV: 299.41' 100 YR ELEV: 300.50' ELEV: 301.00' ELEV: 300.00' SCM #2 - DRY DETENTION POND ANTI-VORTEX TRASH RACK BY PLASTIC SOLUTIONS OR EQUAL CREST OF RISER ELEVATION: 299.00' CONCRETE RISER CENTERLINE OF DAM INSTALL 4" PVC TEE WITH SCREW TYPE PLUG ONCE SKIMMER IS REMOVED AND POND NO LONGER OPERATES AS A TEMPORARY SEDIMENT BASIN BARREL INV. IN ELEVATION: 296.00' CONCRETE ANTI-FLOTATION BLOCK @ BASE ELEVATION SEE TABLE FOR DIMENSIONS 5'X5'X5" CONCRETE ANTI-SEEP COLLAR LOCATED SLIGHTLY DOWNSTREAM FROM CENTERLINE OF DAM (MINIMUM 2' FROM PIPE JOINT) BARREL INV. OUT ELEVATION: 295.70' RIPRAP OUTFALL PROTECTION END SECTION DAM WIDTH: 10' TOP OF DAM ELEVATION 24" RCP BARREL 50' EMERGENCY SPILLWAY ELEV: 300.00' REINFORCE WITH NAG C350 TOP OF DAM ELEV: 300.00' WIDTH: 10' 4'x4' RISER STRUCTURE TOP: 299.00' 6"x24" ORIFICE @ 297.50' 8" ORIFICE @ 296.00' BARREL INV OUT: 296.00' 60 LF 24" RCP @ 0.50% 9'x18'x18" CLASS B RIPRAP INV: 296.00' SCM NUMBER BASIN VOLUME TO SPILLWAY CREST (CF) EMERGENCY SPILLWAY LENGTH (FT) ANTI-FLOTATION BASE DIMENSIONS #2 66,184 50 5'x5'x1.5' THICK RISER 4'x4' NOTE: CROSS SECTION NOT TO SCALE 8" ORIFICE ELEVATION: 296.00' SCALE: N.T.S. EMERGENCY SPILLWAY SECTION 2.5 1 2.5 1 TOP OF EMBANKMENT ELEV.: 301.00' PERMANENT SPILLWAY CREST ELEV.: 300.00' REINFORCE WITH NAG C350 50' INV: 295.70' 6'x12'x18" CLASS B RIPRAP SECONDARY 6"x24" ORIFICE ELEVATION: 297.50' 36" RCP300 297 298 299 301 301 302 302305 300 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C7.1-SCM.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 SCM 3 DETAILSC7.3 0 SCALE 1"=20' 40'20'NAD 8 3 WETLANDS OPEN SPACE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND EMERGENCY SPILLWAY ELEVATION 3:1 SLOPE3:1 SLOPENOTE: INSTALL RUBBER GASKETS ON ALL PIPE JOINTS FOR WATERPROOFING1 YR ELEV: 298.71' 10 YR ELEV: 300.31' 100 YR ELEV: 301.21' ELEV: 302.00' ELEV: 301.00' SCM #3 - DRY DETENTION POND ANTI-VORTEX TRASH RACK BY PLASTIC SOLUTIONS OR EQUAL CREST OF RISER ELEVATION: 300.00' CONCRETE RISER CENTERLINE OF DAM INSTALL 4" PVC TEE WITH SCREW TYPE PLUG ONCE SKIMMER IS REMOVED AND POND NO LONGER OPERATES AS A TEMPORARY SEDIMENT BASIN BARREL INV. IN ELEVATION: 297.00' CONCRETE ANTI-FLOTATION BLOCK @ BASE ELEVATION SEE TABLE FOR DIMENSIONS 5'X5'X5" CONCRETE ANTI-SEEP COLLAR LOCATED SLIGHTLY DOWNSTREAM FROM CENTERLINE OF DAM (MINIMUM 2' FROM PIPE JOINT) BARREL INV. OUT ELEVATION: 296.78' RIPRAP OUTFALL PROTECTION END SECTION DAM WIDTH: 10' TOP OF DAM ELEVATION 24" RCP BARREL 30' EMERGENCY SPILLWAY ELEV: 301.00' REINFORCE WITH NAG C350 TOP OF DAM ELEV: 302.00' WIDTH: 10' 4'x4' RISER STRUCTURE TOP: 300.00' 6"x24" ORIFICE @ 298.80' 8" ORIFICE @ 297.00' BARREL INV OUT: 297.00' 44 LF 24" RCP @ 0.50% 9'x18'x18" CLASS B RIPRAP INV: 298.00' NOTE: CROSS SECTION NOT TO SCALE SCALE: N.T.S. EMERGENCY SPILLWAY SECTION 2.5 1 2.5 1 TOP OF EMBANKMENT ELEV.: 302.00' PERMANENT SPILLWAY CREST ELEV.: 301.00' REINFORCE WITH NAG C350 30' INV: 296.78' 6'x12'x18" CLASS B RIPRAP 8" ORIFICE ELEVATION: 297.00' SCM SIDES AND WEIR SHALL HAVE MAXIMUM SLOPES OF 3:1 OR FLATTER DIMENSIONS SHOWN ARE AT WEIR ELEVATION OF BASIN. BASIN VOLUMES PROVIDED ARE BASED ON AVAILABLE VOLUME AT THE PRINCIPAL SPILLWAY. SCM NUMBER BASIN VOLUME TO SPILLWAY CREST (CF) EMERGENCY SPILLWAY LENGTH (FT) ANTI-FLOTATION BASE DIMENSIONS #3 26,185 30 5'x5'x1.5' THICK RISER 4'x4' SECONDARY 6"x24" ORIFICE ELEVATION: 298.80' STANDARD CUSTOM BASIN ATTACHED TO PERMANENT RISER PLAN VIEW SECTION 'A-A' STANDARD PIPE OUTLET TO FLAT AREA NO WELL-DEFINED CHANNEL STANDARD CONSTRUCTION ENTRANCE STANDARD TEMPORARY DIVERSION DITCH STANDARD TEMPORARY SILT FENCE STANDARD CHECK DAM STANDARD SKIMMER SUPPORT ROPE TO WIRE TO PREVENT SAGGING SUPPORT POST 24" INTRO BOTTOM OR SIDE STAKE TO SUPPORT WIRE COIR MESH OR SIMILAR, STAPLED OR TRENCHED INTO BOTTOM OR SIDE NOTES: 1.BAFFLE MATERIAL SHOULD BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR SILT FENCE. 2.MOST OF THE SEDIMENT WILL ACCUMULATE IN THE 1ST BAY, WHICH SHOULD BE READILY ACCESSIBLE FOR MAINTENANCE. 3.PROVIDE 3 BAFFLES (USE TWO IF LESS THAN 20 FEET IN LENGTH). PROVIDE 5 BAFFLES FOR DRAINAGE AREAS GREATER THAN 10 ACRES. 4.BAFFLE SHALL BE 700 G/M2 COIR EROSION BLANKET. 5.TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE BERMS 6.INSPECT BAFFLES FOR REPAIR ONCE A WEEK AND AFTER EACH RAINFALL CROSS SECTION SECTION VIEW AT OPENING FENCE AND FABRIC BURIED IN TRENCH 6"X6" TRENCH, BACKFILLED AND COMPACTED STEEL POST OUTLET ZONE INLET ZONE 35% OF BASIN SURFACE AREA 1ST CELL 25% OF BASIN SURFACE AREA 2ND CELL 25% OF BASIN SURFACE AREA 15% OF BASIN SURFACE AREA PLAN VIEW STANDARD BAFFLES STANDARD SILT FENCE OUTLET JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C8.1-NTDT.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 NOTES & DETAILSC8.1 CHANNEL INSTALLATION DETAIL Drawing Not To Scale 1.Prepare soil before installing rolled erosion control products (RECPs), including any necessary application of lime, fertilizer, and seed. 2.Begin at the top of the channel by anchoring the RECPs in a 6"(15cm) deep X 6"(15cm) wide trench with approximately 12"(30cm) of RECPs extended beyond the up-slope portion of the trench. Use ShoreMax mat at the channel/culvert outlet as supplemental scour protection as needed. Anchor the RECPs with a row of staples/stakes approximately 12"(30cm) apart in the bottom of the trench. Backfill and compact the trench after stapling. Apply seed to the compacted soil and fold the remaining 12"(30cm) portion of RECPs back over the seed and compacted soil. Secure RECPs over compacted soil with a row of staples/stakes spaced approximately 12" apart across the width of the RECPs. 3.Roll center RECPs in direction of water flow in bottom of channel. RECPs will unroll with appropriate side against the soil surface. All RECPs must be securely fastened to soil surface by placing staples/stakes in appropriate locations as shown in the staple pattern guide. 4.Place consecutive RECPs end-over-end (Shingle style) with a 4"-6" overlap. Use a double row of staples staggered 4" apart and 4" on center to secure RECPs. 5.Full length edge of RECPs at top of side slopes must be anchored with a row of staples/stakes approximately 12"(30cm) apart in a 6"(15cm) deep X 6"(15cm) wide trench. Backfill and compact the trench after stapling. 6.Adjacent RECPs must be overlapped approximately 2"-5" (5-12.5cm) (Depending on RECPs type) and stapled. 7.In high flow channel applications a staple check slot is recommended at 30 to 40 foot (9 -12m) intervals. Use a double row of staples staggered 4"(10cm) apart and 4"(10cm) on center over entire width of the channel. 8.The terminal end of the RECPs must be anchored with a row of staples/stakes approximately 12" (30cm) apart in a 6"(15cm) deep X 6"(15cm) wide trench. Backfill and compact the trench after stapling. Drawn on: 5-4-17 Disclaimer: The information presented herein is general design information only. For specific applications, consult an independent professional for further design guidance. 2"-5" (5-12.5cm) 6 2 4 12"(30cm) 6" (15cm) 6" (15cm) 4"-6" (10-15cm) 8 6" (15cm) 5 7 4"(10cm) 3 1 A B C A B C NOTES: *Horizontal staple spacing should be altered if necessary to allow staples to secure the critical points along the channel surface. **In loose soil conditions, the use of staple or stake lengths greater than 6"(15cm) may be necessary to properly secure the RECP's. CRITICAL POINTS A. Overlaps and Seams B. Projected Water Line C. Channel Bottom/Side Slope Vertices 4"(10cm) 6" (15cm) 5401 St. Wendel - Cynthiana Rd. Poseyville, IN 47633 PH: 800-722-2040 www.nagreen.com CONCRETE WASHOUT STATION DETAIL JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C8.1-NTDT.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 NOTES & DETAILSC8.2 NCG01 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19 GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCG01 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCG01 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1.Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2.Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3.Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4.Provide ponding area for containment of treated Stormwater before discharging offsite. 5.Store flocculants in leak-proof containers that are kept under storm-resistant cover or surrounded by secondary containment structures. HAZARDOUS AND TOXIC WASTE 1.Create designated hazardous waste collection areas on-site. 2.Place hazardous waste containers under cover or in secondary containment. 3.Do not store hazardous chemicals, drums or bagged materials directly on the ground. EQUIPMENT AND VEHICLE MAINTENANCE 1.Maintain vehicles and equipment to prevent discharge of fluids. 2.Provide drip pans under any stored equipment. 3.Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4.Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5.Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6.Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1.Never bury or burn waste. Place litter and debris in approved waste containers. 2.Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3.Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4.Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5.Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6.Anchor all lightweight items in waste containers during times of high winds. 7.Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8.Dispose waste off-site at an approved disposal facility. 9.On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1.Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2.Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3.Contain liquid wastes in a controlled area. 4.Containment must be labeled, sized and placed appropriately for the needs of site. 5.Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1.Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2.Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3.Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. HERBICIDES, PESTICIDES AND RODENTICIDES 1.Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2.Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3.Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4.Do not stockpile these materials onsite. CONCRETE WASHOUTS 1.Do not discharge concrete or cement slurry from the site. 2.Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3.Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4.Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5.Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6.Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7.Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8.Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9.Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10.At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. EARTHEN STOCKPILE MANAGEMENT 1.Show stockpile locations on plans. Locate earthen-material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2.Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3.Provide stable stone access point when feasible. 4.Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. Site Area Description Timeframe variations -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed unless there is zero slope Stabilize within this many calendar days after ceasing land disturbance 7 7 7 14 None None (a)Perimeter dikes, swales, ditches, and perimeter slopes (b)High Quality Water (HQW) Zones (c)Slopes steeper than 3:1 If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed (d)Slopes 3:1 to 4:1 (e)Areas with slopes flatter than 4:1 14 -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed NCG01 SELF-INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/19 PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF-INSPECTION Self-inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self-inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION B: RECORDKEEPING 1.E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be kept on site and available for inspection at all times during normal business hours. 2. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above, the following items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides a site-specific exemption based on unique site conditions that make this requirement not practical: (a)This General Permit as well as the Certificate of Coverage, after it is received. (b)Records of inspections made during the previous twelve months. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically-available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard-copy records. PART III SELF-INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1.Occurrences that Must be Reported Permittees shall report the following occurrences: (a)Visible sediment deposition in a stream or wetland. (b)Oil spills if: ·They are 25 gallons or more, ·They are less than 25 gallons but cannot be cleaned up within 24 hours, ·They cause sheen on surface waters (regardless of volume), or ·They are within 100 feet of surface waters (regardless of volume). (c) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (d)Anticipated bypasses and unanticipated bypasses. (e)Noncompliance with the conditions of this permit that may endanger health or the environment. 2.Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Center personnel at (800) 858-0368. 3. Documentation to be Retained for Three Years All data used to complete the e-NOI and all inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather). Non-surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a)The E&SC plan authority has been provided with documentation of the non-surface withdrawal and the specific time periods or conditions in which it will occur. The non-surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b)The non-surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c)Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems, (d)Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e)Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f)Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States. STANDARD HORSESHOE INLET PROTECTION RESTRAINING GLANDS RESTRAINING GLANDS UNDISTURBED EARTH. 7 CU. FT. CRUSHED STONE MIN. 1'-3"x 1'-3"x 4" THICK MAIN 6" MIN. BRANCH PIPE 1'- 0" 6" GATE VALVE CONC. THRUST BLOCK VALVE BOX 2'-6' MIN.SIDEWALK CURB AND GUTTER PAVEMENT TRAFFIC FLANGE BETWEEN 2" - 6" ABOVE GRADE FIRE HYDRANT, PUMPER NOZZLE TO BE POINTED TOWARDS FIRE TRUCK ACCESS. PROPERTY LINE COMPACTED BACKFILL (TAMPED IN 6" LIFTS) STANDARD FIRE HYDRANT INSTALLATION DETAIL MINIMUM 36" HORIZONTAL CLEARANCE FROM ANY OBJECT. NOTES: 1. FIRE HYDRANT SHALL BE AS MANUFACTURED: MUELLER, AMERICAN DARLING, KENNEDY, M&H, WATEROUS, CLOW, EAST JORDAN IRON WORKS, OR US PIPE. 2. BRANCH PIPE SHALL BE DUCTILE IRON AWWA C150-96 3. 6" GATE VALVE SHALL BE AWWA C500-86 OPEN LEFT 4. STEEL RODS AND BOLTS SHALL BE 3 4" HOT DIPPED GALVANIZED 5. FIRE HYDRANTS WILL BE INSTALLED IN TRUE VERTICAL POSITION RODS SHALL NOT BE COUPLED MORE THAN ONCE. IF THE LENGTH FROM THE VALVE TO THE HYDRANT EXCEEDS 20' THEN A MECHANICAL RESTRAINING GLAND WITH A REBAR CAGE SHALL BE INSTALLED NO MORE THAN 10' FROM HYDRANT AND POURED IN CONCRETE. FIRE HYDRANTS TO BE LOCATED IN ROW OR 2 FOOT EASEMENT ADJACENT TO ROW ANYTIME SITE WORK, CONSTRUCTION, ROAD WORK, OR ANY OTHER WORK CHANGES THE GRADE OF THE FIRE HYDRANT, THE PERSON RESPONSIBLE FOR THE WORK IS RESPONSIBLE FOR ADJUSTING THE FIRE HYDRANT TO STAY WITHIN COMPLIANCE. 3" MIN. CLEARANCE "X" BAR THRUST COLLAR 3" MIN. CLEARANCE"Y" BAR UNDISTURBED SOIL "C" "B"O.D.PIPE"A""A""D" NOTES: 1. CONCRETE SHALL BE 3000 PSI AND TRANSIT MIXED. 2. REINFORCING BARS SHALL BE DEFORMED AND TIED TOGETHER. THRUST COLLAR, AND THRUST SCHEDULE REINFORCING REQUIREMENTS THRUST BLOCKING DESIGN DATA FOR WATER MAINS 3. BACKFILL TAMPED IN 6" LIFTS 4. THRUST COLLAR MUST BE FACTORY WELDED ON BOTH SIDES ALONG BOTH EDGES OF COLLAR AROUND CIRCUMFERENCE. 6" - 16" 20" - 24" 30" - 36" 48" & greater 1'-4" 1'-4" 1'-4" 1'-8"1'-9" 1'-7" 1'-7" 1'-7"2" 3" 4" 6"7/8" 5/8" 1/2" 3/8" "D""A""B""C"I.D. PIPE MECHANICALJOINTRETAINERGLAND3/4" THREADEDSTEEL RODS5' MIN.STRAPDOWNTOP OF GROUNDNO. OF RODS REQUIREDCONCRETE THRUST BLOCK ATALL 45° BENDS SEE W-10 ANDW-11.ADD MECHANICAL JOINTRETAINER GLANDSTHROUGHOUT ASSEMBLY.SIZE OF 45 BENDROD REQUIREMENTSSTATIC THRUST IN POUNDSSTANDARD VERTICAL BEND5' MINTHRUST COLLAR SEEW-10 THRU W-11.STRAPDOWNNOTES: 1. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT FITTINGS. SIDE VIEW TAPPING SLEEVE M.J. FITTING VALVE FLANGE EXISTING MAIN 3000 PSI SOLID CONCRETE SHALL BE USED AS FOOTING FOR DUCTILE IRON PIPE. GATE / TAPPING VALVE TOP VIEW 4" - 24" STANDARD TAPPING SLEEVE AND VALVE ASSEMBLY 3/4" ALL-THREAD STEEL ROD (CUT TO LENGTH) GATE VALVE ROD REQUIREMENTS NO. OF RODS BRANCH SIZE SEE W-10 AND W-11 FOR REACTION BLOCKING CONCRETE AREA. TEE NOTES: 1. STEEL RODS AND BOLTS SHALL BE 3/4" HOT DIPPED GALVANIZED. 2. SEE STANDARD THRUST BLOCK. TABLES W-10 AND W-11 FOR CONCRETE. 3. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL FITTINGS. 4. THIS RODDING REQUIREMENT DOES NOT APPLY TO FIRE HYDRANTS. VALVE RESTRAINT AT TEES AND CROSSES FOR LINES (4"-24") SEE STANDARD W-18 FOR COVER DETAILS. FINAL COURSE CONCRETE PAD VALVE BOX INSTALLATION AND EXTENSION DETAIL STANDARD VALVE BOX BOTTOM SECTION STAB-IN C.I. OR D.I. PIPE GASKET TAMPED BACKFILL WATER MAIN VALVE VALVE BOX USE 5" SOIL PIPE FOR EXTENSIONS PAVEMENT DOMESTIC CASTING NOTE: 2'x 2'x 6" CONCRETE PAD REQUIRED ON ALL VALVES. NO PRECAST CONCRETE DOUGHNUT ALLOWED. APPROVED METHOD FOR EXTENSION OF VALVE BOX STANDARD VALVE BOX TOP SECTION TO BE SLIDE SECTION MJFITTINGMIN. 5'MAX. 10'MECHANICALRESTRAININGGLANDNOTES:1) NO ROD COUPLINGS ALLOWED6"-8"MIN. 5'MAX. 10'BLIND FLANGE WITH2" THREADED PLUGGROUND LINE ORPAVEMENT3000 P.S.I.CONCRETERODDINGLP OR PHASE LINEDETAIL W-20 TO BEUSED SEE STANDARDMANHOLE COVERX FLANGE PIPE:PLAIN END#67STONE3000 PSI CONCRETEWITH 4" THICKNESSVALVE BLOWOFFGALVANIZED STEEL RODS ANDBOLTS SHALLBE 3/4" HOT DIPPEDBLOCK INFORMATION SEEDETAILS W-7, W-8& W-9 FOR THRUSTMAIN SIZE16" & GREATER6" - 12"END PIPE SIZE6" MIN.APPROVED BY PUBLICUTILITIES DEPT.TEMPORARY WATER MAIN BLOW OFF ASSEMBLY14" WEEPHOLENOTES: 1. COVER WEIGHT: 13 LBS +/- 5% 2. LIDS TO BE COATED WITH BITUMINOUS COAL TAR COATING 3. HOLE SHALL BE FITTED WITH A METAL GROMMET SECTION C-C 1.8" O PRE-DRILLED HOLE SECTION A-A WATER METER BOX DETAIL SECTION B-B EXISTING PAVEMENT NEW ASPHALT SURFACE COARSE 3" MINIMUM EXISTING PAVEMENT NEW ABC 12" MIN. DEPTH 1'-0"EXISTING SUBGRADE UNDISTURBED SOILCOMPACTED FILL IN 6" LIFTS PIPE REFER TO W-3 NOTES: 1. THE PAVEMENT CUT SHALL BE DEFINED BY A STRAIGHT EDGE AND CUT WITH AN APPROPRIATE SAW CUT MACHINE. 2. THE TRENCH SUBGRADE MATERIAL SHALL BE BACKFILLED WITH SUITABLE MATERIAL AND COMPACTED TO A DENSITY OF AT LEAST 95% OF THAT OBTAINED BY COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE WITH AASHTO T-99 AS MODIFIED BY NCDOT. 3. THE FINAL 1' OF FILL SHALL CONSIST OF ABC MATERIAL COMPACTED TO A DENSITY EQUAL TO 100% OF THAT OBTAINED BY COMPACTING A SAMPLE OF THE MATERIAL IN ACCORDANCE WITH AASHTO T-80 AS MODIFIED BY NCDOT. 4. THE ENTIRE THICKNESS/ VERTICAL EDGE OF CUT SHALL BE TACKED. 5. THE SAME DEPTH OF PAVEMENT MATERIAL WHICH EXISTS SHALL BE REINSTALLED, BUT IN NO CASE SHALL THE ASPHALT BE LESS THAN 3" THICK. 6. THE ASPHALT PAVEMENT MATERIAL SHALL BE INSTALLED AND COMPACTED THOROUGHLY WITH A SMOOTH DRUM ROLLER TO ACHIEVE A SMOOTH LEVEL PATCH. 7. NO HAND PATCHING ALLOWED. 8. PAVEMENT CUTS WITHIN NCDOT ROW SHALL CONFORM TO THE APPROVED ON SITE ENCROACHMENT PERMIT. STANDARD ASPHALT PAVEMENT PATCH DETAIL EXISTING ABC JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C8.1-NTDT.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 NOTES & DETAILSC8.3 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C8.1-NTDT.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 NOTES & DETAILSC8.4 SANSANWWWWS S SAN SAN W W S WWW1819202122 31 32 33 35 40 58 65 66 68 63 67 16 15 14 444142 64 17 13 3 5 4 1 70 2 69 23 29 34 36 30 37 38 28 26 24 27 25 8 43 49 46 45 52 59 39 47 48 51 56 55 54 53 57 60 62 50 12 11 10 9 61 7 6S S S S S S SSSSSSS S SAN SAN SAN SAN SANSANSANSANSAN SSSANSANSAN OPEN SPACE AREA #1 189,468 SF 4.35 AC SCM #1 SCM #2 SCM #3 OPEN SPACE AREA #2 46,107 SF 1.06 AC OPEN SPACE AREA #3 200,821 SF 4.61 AC 6''W6''W6''W6''W6''W6' 'W6' 'W6' 'W 6''W 6''W 6''W 6''W 6''W 6''W 6''W6''W6''W6''W6''W6''W 6''W 6''W 6''W 6''W 6''W6''W6''W WETLANDS WETLANDS WETLANDS SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY SITE BOUNDARY MAIL KIOSK STREET TREE (TYP) STREET TREE (TYP) STREET TREE (TYP) STREET TREE (TYP)FIRE LANESOUTH S T R E E T 60' ROW MAIN STREET60' ROWJOHNSON STREET 60' ROWBREWER AVENUE60' ROWCONDUCTOR COURT CON D U C T O R C O U R T LANDSCAPE PLANC9.0 JOB NO. SHEET NO. SCALE DESIGNED BY CHECKED BYDATEDRAWN BY DATEREVISION DESCRIPTIONYOUR VISION ACHIEVED THROUGH OURS.These plans and associated documents are the exclusive property of TIMMONS GROUP and may not be reproduced in whole or in part and shall not be used for any purpose whatsoever, inclusive, but notlimited to construction, bidding, and/or construction staking without the express written consent of TIMMONS GROUP.S:\331\38790-Vass Mixed Use\DWG\Sheet\CD\38790-C9.0-PLNT.dwg | Plotted by Bryant IngeNORTH CAROLINA LICENSE NO. C-16525410 Trinity Road, Suite 102 | Raleigh, NC 27607TEL 919.866.4951 FAX 919.833.8124 www.timmons.comTHIS DRAWING PREPARED AT THERALEIGH OFFICE11/25/19 WINDER STATION AT VASSMAIN ST, VASS, MOORE COUNTY, NORTH CAROLINA38790 B. INGE B. INGE D. KIRK AS SHOWNN O R T H C A R O L I N AP R O F E S S I O N A LE N G I N E E RD A N I E L L E S . K I R K S E A L 0 4 3 9 2 9 0 SCALE 1"=80' 160'80'NAD 83WETLANDS OPEN SPACE AREA FLOODPLAIN STREAM CENTERLINE SITE PLAN LEGEND