Loading...
HomeMy WebLinkAboutNC0083313_Inspection_20191212EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0083313 19/12/11 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Brookside Village Condos WWTP 59 Brookside Dr Hendersonville NC 28792 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 11:30AM 19/12/11 16/04/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Mark Brandon Jones/ORC/828-273-0760/ Other Facility Data 12:00PM 19/12/11 20/11/30 Name, Address of Responsible Official/Title/Phone and Fax Number Donna Berard,538 N Main St Hendersonvlle NC 28792/VP of Association/828-696-2173/ Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Operations & Maintenance Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date G. Landon Davidson DWR/ARO WQ/828-296-4500/ Daniel J Boss DWR/ARO WQ/828-296-4658/ Timothy H Heim DWR/ARO WQ/828-296-4665/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: F5CD34CA-9FA6-49D2-BC0F-69726E6CACC6 12/12/2019 12/12/2019 12/12/2019 NPDES yr/mo/day 19/12/11 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) This was a follow up inspection to check the repair of the tertiary filters at the Brookside WWTP. Tim Heim, Landon Davidson, and I (Daniel Boss) all conducted the inspection and we met onsite with Mark Jones (ORC) who guided us through the tertiary filter operation. The tertiary filters are now fully functional, but Mr. Jones is still in the process of remediating the tertiary filter operation. All the pumps and blowers are now working, but Mr. Jones believes that there are still some solids trapped in a bottom layer of the media which is limiting the ability of the filter to backwash. Mr. Jones has access to the outfall and has identified the location of the discharge. He is still in the process of clearing the full right of way. NC0083313 17 (Cont.) Page#2 DocuSign Envelope ID: F5CD34CA-9FA6-49D2-BC0F-69726E6CACC6 Permit:NC0083313 Inspection Date:12/11/2019 Owner - Facility: Inspection Type: Brookside Village Condos WWTP Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Filtration (High Rate Tertiary)Yes No NA NE Type of operation:Down flow Is the filter media present? Is the filter surface free of clogging? Is the filter free of growth? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids and filter media? Mr. Jones is still in the process of remediating the tertiary filter operation. All the pumps and blowers are now operational, but Mr. Jones believes that there is still some solids trapped in a bottom layer of the media which is limiting the ability of the filter to backwash. Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Mr. Jones has found the effluent discharge and cleared a small pathway to it. The full right of way has not yet been cleared however. Comment: Page#3 DocuSign Envelope ID: F5CD34CA-9FA6-49D2-BC0F-69726E6CACC6