HomeMy WebLinkAboutNCG100226_Inspection_20191211Charlotte -Mecklenburg STORM -- WATER Services December 11, 2019 LKQ Salisbury Attn: Jeff Doebler, Plant Manager 3900 Chesapeake Drive Charlotte, NC 28216 Subject: Industrial Facility Inspection LKQ Salisbury Dear Mr. Doebler: 2145 Suttle Avenue Charlotte, NC 28208-5237 On November 21, 2019, Matt Santiago and Corey Baumgardner of Charlotte -Mecklenburg Storm Water Services (CMSWS) conducted an inspection of the above referenced facility as a requirement of the City of Charlotte's NPDES Permit, NCS000240, Part II, Section H. Inspection authority is granted by Charlotte City Code Chapter 18, Article III, Section 18-82. At the time of inspection, the facility was observed to be in compliance with the City of Charlotte Storm Water Pollution Control Ordinance. The inspection was also conducted as part of a cooperative working agreement between Mecklenburg County and the North Carolina Department of Environmental Quality (NCDEQ) — Division of Energy, Mineral and Land Resources (DEMLR). NCDEQ — DEMLR has been copied on this report and made aware of the following observations regarding the facility's NPDES stormwater permit: 1) Stormwater Pollution Prevention Plan (SPPP) A Stormwater Pollution Prevention Plan (SPPP) has been developed, recorded, and implemented. 2) Qualitative Monitoring Qualitative monitoring has been conducted and recorded. 3) Analytical Monitoring Analytical monitoring has been conducted and recorded. 4) Stormwater Facility Inspections A facility inspection was performed on September 4, 2019. No facility inspection was performed for the first half of the year. The facility should conduct semi-annual inspections, one between January and June, and one between July and December. • To report pollution or drainage problems, call: 311 http://stormwater.charmeck.org CHARLOTTE < LKQ Salisbury Attn: Jeff Doebler, Plant Manager Page 2 December 11, 2019 Thank you for the assistance and cooperation with the site inspection. The attached report provides details about inspection observations and should be self-explanatory. Please contact me at (980) 240-3337 if you have any questions or need additional information. For questions specifically regarding your State -issued NPDES Stormwater Certificate of Coverage NCG100226, please contact James Moore with NCDEQ — DEMLR at (704) 663-1699. Sincerely, Matt Santiago Environmental Specialist Charlotte -Mecklenburg Storm Water Services cc: Kristen O'Reilly, Charlotte Storm Water Services James Moore, NCDEQ — DEMLR Zahid Khan, NCDEQ — DEMLR Lily Kay, NCDEQ — DEMLR Attachment ch.wofte-Mecklenburg STORM WATER Facility Services Inspection 2 14 5 Suttle Avenue Charlotte, NC 28208 Facility Name: LKQ Salisbury Inc. Inspection # : 47570 Contact: Jeff Doebler, Plant Manager Permit #: NCGl00226 Inspector: Matthew Santiago Receiving Stream: Stewart Inspection Date: 11/21/2019 Entry Time: 9:30 am Exit Time: 10:30 am SIC #: will'/(,t Facility Description: LKQ Salisbury, Inc. is located at 3900 Chesapeake Drive on approximately 52 acres of property it shares with LKQ Heavy Truck Charlotte. The facility buys used vehicles and sells automotive parts and equipment. File Review/History: This facility was previously inspected by Charlotte -Mecklenburg Storm Water Services on January 29, 2015. The property was observed to be in compliance with the NGC100226 permit and Charlotte -Mecklenburg County Stormwater Pollution Prevention Ordinance. Inspection Summary: During the inspection, the LKQ Salisbury, Inc. facility was observed to be in compliance with the City of Charlotte Stormwater Pollution Control Ordinance. Site Inspection Deficiency Comments Stormwater system (catch basins, No Stormwater runoff drains via sheet flow which leads to an inlets, outfalls, etc.) outfall. Additionally, a series of storm drains which leads to two outfalls. No stormwater issues were observed during the inspection. Erosion issues No No erosion issues were observed during the inspection. Structural stormwater BMPs No Hay bales and absorbent socks were observed around the storm drains across the property. The hay bales and socks appeared to be free of excess staining. No stormwater pollution issues were observed. Illicit discharges/connections No No illicit discharges/connections were observed during the inspection. Above ground storage tank(s), and No ASTs containing waste oil, antifreeze and gasoline were any associated venting — list size and observed on the property. The ASTs were stored undercover contents within secondary containment. No stormwater issues were observed. Underground storage tank(s) - fill port N/A area-, list tank sizes & contents Outdoor material storage area(s) No The facility stores used cars across the property. Minor oil staining was observed around the vehicles as a result of customers removing engine parts. According to facility personnel, stains are cleaned with spill clean material and disposed of. Outdoor processing area(s) N/A Loading/unloading area(s) No No stormwater issues were observed. Vehicle/equipment area(s) - fueling, No Vehicles are stored outside on an asphalt paved lot. No washing, storage, etc. stormwater issues were observed. Oil/water separator and/or N/A pretreatment Waste storage/disposal area - No dum sters, scrap metal bins, etc. obTo report pollution or drainage problems call: 311 CIIA-OTTE http://stormwater.charmeck.org 12/11/2019 3:44:38PM Page 1 of 2 Mo Site Inspection Deficiency Comments Food service area(s) N/A Indoor material storage area(s) No Indoor processing area(s) No Car crushing, sorting, and loading is conducted in an indoor area. No stormwater issues were observed. Floor drains N/A Floor drains were not observed during the inspection. Spill response equipment INo tormwater Pollution Plan Observed Comments Does the facility have a stormwater pollution prevention plan? Yes General location (USGS) map Yes Narrative description of practices Yes Detailed site map Yes List of significant spills (past 3 years) Yes No significant spills were reported over the past three years. Non-stormwater discharge evaluation of outfall(s) Yes Evaluations were conducted March 13, 2019 and October 16, 2019. Feasibility study Yes All necessary secondary containment provided Yes Collected water evaluated and documented prior to release N/A BMP Summary Yes Spill prevention and response plan Yes Preventative maintenance and good housekeeping plan Yes Facility provides and documents employee training Yes Employee training was conducted on November 18, 2019. List of responsible parties Yes Reviewed and updated annually Yes The SPPP was reviewed and updated on August 23, 2019. Stormwater facility inspection program conducted semi-annually Recommendation The facility was inspected on September 4, 2019. The facility should conduct semi-annual inspections, one between January and June, and one between July and December. Qualitative/Analytical Monitoring Observed Comments Qualitative monitoring conducted semi-annually Yes Qualitative Monitoring was conducted on March 13, 2019 and October 16, 2019. Analytical monitoring conducted semi-annually Yes Analytical monitoring was conducted on March 11, 2019 and October 16, 2019. Analytical monitoring from vehicle maintenance Yes Analytical monitoring was conducted on March 11, 2019 and October 16, 2019. Permit and Outfalls Observed Comments Copy of permit and certificate of coverage onsite Yes The Certificate of Coverage was dated November 15, 2018 and a 2019 renewal was requested. All outfalls observed Yes No stormwater issues were observed Number of Outfalls Observed 1 Representative outfall status documented by NCDWQ N/A Annual no -exposure self re -certification documented N/A Ohl 'a To report pollution or drainage problems call: 311 '^'{�, CTUR E. http://stormwater.charmeck.org ``` 12/11/2019 3:44:38PM Page 2 of 2