HomeMy WebLinkAboutNCG551038_Compliance Evaluation Inspection_2019121095 pt MAILED ROY COOPER,, �?; A•i�_L _ �. MICHAEL S. REGAN S.xraary ww r LINDA CULPEPPER NORTH CAROLINA afro:tcl Environmental Quality December 10, 2019 Pfizer Attn: Chuck Powell, Environmental Health & Safety 4300 Oak Park Rd Sanford NC 27330-9550 Subject: Compliance Evaluation Inspection Wyeth Security Building SFR Permit No. NCG551038 Lee County Dear Mr. Powell: On November 13, 2019, Joan Schneier from the Raleigh Regional Office visited your single- family residence (SFR) wastewater treatment system to evaluate compliance with the above pen -nit to discharge wastewater. The assistance from you and Connor Jarvis during the inspection was greatly appreciated. The checked boxes below show what conditions were noted at your facility: ® In compliance: You are reminded to regularly maintain the chlorine disinfection system, have the effluent sampled once a year (if it is present), and have the septic tank pumped out every 3 to 5 years. ® Other: Please run your system for a long time at least once a year to verify that effluent does exit and the outlet pipe is not blocked or broken. Also please check the chlorinator and dechlorinator once in a while to verify that your contractor is maintaining tablets in the system. If you have questions or comments about this inspection or the requirements to take corrective action, please contact Joan Schneier or me at 9 l 9-791-4200 or joan.schneier c nedenr.gov or scott.vinson ct,ncdenr.gov. ;1 rirt(.ur'li•..f).f.erhrtrt )fFn'.-r'•rtl+lt•tl(,?rttlry f)r:"�,i�,nfit 6LttVific-StFw!c, ✓f"� R1;.•r,f1U yina'0! r A'100!'i rtttp'•-C. L.dciuli.`olfh( cuhna3ir09 u.o.m�hr<ru.,-.:�..r�wa•..1:� �s r7f•)7rzf,flUf) Sincerely, Scott Vinson, Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachments: Inspection Report cc: (minus attachments) RRO?SWP Files NPDES files by Laserfiche United Slates Environmental Protection Agency Form Approved EPA Washington, D C 20460 OMB No 2040-0057 Water Compliance Inspection Report Approval expires 8-31 -98 Section k National Data System Coding (i.e., PCS) Transaction Code NPDES yrlmolday Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCG551038 _ I11 12 19/11/13 17 18 1 j,J 1 LJ LJ L 19 1 g ( 20 ( L_J l_J 21 g Inspection Work Days Fa{ lity Self Mon-tortngEva uaf r Rat' g B 1 OA Reserved 67 70 U 71 72 U 73 W 74 751 1 1 1 1 1 1 180 Section B: Facility Data Name and Location of Facility Inspected i.For'ndustrial Users disrharg:ng to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES hermit Number) 02:0013M 19111/13 18/11/13 Wyeth Security Building Exit TimelDate Permit Expiration Date 3316 Hawk ns Blvd Sanford NC 27330 02:55PNI 19/11/13 20/10/31 Name(s) of Onsite Representative(s:rTities(si'Phone and Fax Numb=_rfs) Other Facility Data Name, Address of Respons!ble Off cialfritle.Phone and Fax Nimbep Contacted Lynn A Battone, 1!! No Section C: Areas Evaluated During Inspeo'on (Check only those areas evaluated) Permit 0 Operations & Maintenance ■ Effluent/Receiving Waters Section D: Summary of Finding; Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signalure(s) of Inspector(s) Agency/OfficelPhone and Fax Numbers Date Joan Schneier DWRIRRO GW1919-79142001 1 U i 3 f a l a OI q Signature of Managepent O A Reviewer AgencylOKcelPhone and Fax Numbers Date I 2- PA Form 3560.3 (Rev 9.94) Previous editions are obsolete Page# NPDES yrlmolday Inspection Type (Cont.) 31 NCG551038 11 12I 19111/13 117 18 ICI Section D: Summary of FindinglComments (Attach additional sheets of narrative and checklists as necessary) The system consists of a septic tank, underground sand filter, chlorinator, dechlorinator, outfall pipe, and riprap. All flow is by gravity. All tank lids were opened for inspection. Chuck Powell and Connor Jarvis of Pfizer assisted during the field inspection and record review. Addition of tablets, septic tank cleanouts, and quarterly attempts (all unsuccessful) to find flow to sample were all documented. The facility seems to have very high standards for cleanliness, safety, and documentation. A high TSS in 2010 was attributed to a partial outlet pipe blockage by soil.Procedures are now in place to clean the pipe area periodically, per permittee. DWR recommends checking the tablet status periodically between additions to be sure there is some substance present and also running enough water to verify that flow is still active through the pipe. R37# 2 Permit: NCG561038 Owner - Facility: Wyeth Security 6ui ding Inspection Date: 1113l2019 Inspection Type: Compliance Eva: uaticn Permit (If the present permit expires in fi months or less), Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: This system only services the -guardhouse, which is open for about one shift daily. Visitors must check in and be escorted around the facility. Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters_ for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Septic Tank (If pumps are used) Is an audible and v:sual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Yes No NA NE ❑ ❑ ■ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ■ ❑ Yes No NA NE Comment: The septic tank is pumped out eveN 2 years. It was done on 4/30/18 and 4130116 b Donathan Pumping Service in Cameron. The effluent filter was reasonably clean. Sand Filters (Low rate) (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filler free of ponding? Is the sand filter effluent re -circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) Comment, The subsurface sand filter and large surrounding area are kept closely mowed. Disinfection -Tablet Are tablet chlorinators operational? Are the tablets the proper size and type? ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ Yes No NA NE Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ❑ Page# 3 Permit: NCG551038 Owner - Facility: Wyeth Security Building inspection Date: 11113/2019 Inspection Type: Compliance Evaluation Disinfection -Tablet Yes No NA NE Number of tubes in use? Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ E Comment: Tablets are dropped in bi-weekly, per records. Sodexo Co. handles this and keeps the tablets elsewhere. Tablets were dissolved with only slight traces remaining, when inspected. De -chlorination Yes No NA NE Type of system ? Tablet Is the feed ratio proportional to chlorine amount (1 to 1 )? 0 ❑ ❑ ❑ Is storage appropriate for cylinders? Cl ❑ 0 ❑ # Is de -chlorination substance stored away from chlorine containers? ❑ ❑ ❑ 0 Comment: Are the tablets the proper size and type? ❑ ❑ ❑ 0 Are tablet de -chlorinators operational? M ❑ ❑ ❑ Number of tubes in use? 1 Comment: Same comments as for chlorinator tablets. Effluent Pie Yes No NA NE Is right of way to the outfall properly maintained? M ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? M ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ M ❑ Comment: The outlet pipe and the downhill riprap were clean. The outlet area has a single chain fence. Page# 4