Subject: Compliance Evaluation Inspection
Wyeth Security Building SFR
Permit No. NCG551038
Lee County
Dear Mr. Powell:
On November 13, 2019, Joan Schneier from the Raleigh Regional Office visited your single-
family residence (SFR) wastewater treatment system to evaluate compliance with the above
pen -nit to discharge wastewater. The assistance from you and Connor Jarvis during the
inspection was greatly appreciated. The checked boxes below show what conditions were noted
at your facility:
® In compliance: You are reminded to regularly maintain the chlorine disinfection
system, have the effluent sampled once a year (if it is present), and have the septic tank
pumped out every 3 to 5 years.
® Other: Please run your system for a long time at least once a year to verify that
effluent does exit and the outlet pipe is not blocked or broken.
Also please check the chlorinator and dechlorinator once in a while to verify that your
contractor is maintaining tablets in the system.
If you have questions or comments about this inspection or the requirements to take corrective
action, please contact Joan Schneier or me at 9 l 9-791-4200 or joan.schneier c nedenr.gov or
scott.vinson ct,ncdenr.gov.
;1 rirt(.ur'li•..f).f.erhrtrt )fFn'.-r'•rtl+lt•tl(,?rttlry f)r:"�,i�,nfit 6LttVific-StFw!c,
✓f"� R1;.•r,f1U yina'0! r A'100!'i rtttp'•-C. L.dciuli.`olfh( cuhna3ir09
u.o.m�hr<ru.,-.:�..r�wa•..1:� �s r7f•)7rzf,flUf)
Sincerely,
Scott Vinson, Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachments:
Inspection Report
cc: (minus attachments)
RRO?SWP Files
NPDES files by Laserfiche
United Slates Environmental Protection Agency
Form Approved
EPA Washington, D C 20460
OMB No 2040-0057
Water Compliance Inspection Report
Approval expires 8-31 -98
Section k National Data System Coding (i.e., PCS)
Transaction Code NPDES yrlmolday Inspection Type
Inspector Fac Type
1 IN 1 2 15 I 3 I NCG551038 _ I11 12 19/11/13 17 18 1 j,J 1
LJ LJ L
19 1 g ( 20 (
L_J l_J
21
g
Inspection
Work Days Fa{ lity Self Mon-tortngEva uaf r Rat' g B 1 OA
Reserved
67
70 U 71 72 U 73 W 74 751 1 1 1 1 1 1 180
Section B: Facility Data
Name and Location of Facility Inspected i.For'ndustrial Users disrharg:ng to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES hermit Number)
02:0013M 19111/13
18/11/13
Wyeth Security Building
Exit TimelDate
Permit Expiration Date
3316 Hawk ns Blvd
Sanford NC 27330
02:55PNI 19/11/13
20/10/31
Name(s) of Onsite Representative(s:rTities(si'Phone and Fax Numb=_rfs)
Other Facility Data
Name, Address of Respons!ble Off cialfritle.Phone and Fax Nimbep
Contacted
Lynn A Battone, 1!!
No
Section C: Areas Evaluated During Inspeo'on (Check only those areas evaluated)
Permit 0 Operations & Maintenance ■ Effluent/Receiving Waters
Section D: Summary of Finding; Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signalure(s) of Inspector(s) Agency/OfficelPhone and Fax Numbers
Date
Joan Schneier DWRIRRO GW1919-79142001
1
U
i 3 f a l a OI q
Signature of Managepent O A Reviewer AgencylOKcelPhone and Fax Numbers
Date
I 2-
PA Form 3560.3 (Rev 9.94) Previous editions are obsolete
Page#
NPDES yrlmolday Inspection Type (Cont.)
31 NCG551038 11 12I 19111/13 117 18 ICI
Section D: Summary of FindinglComments (Attach additional sheets of narrative and checklists as necessary)
The system consists of a septic tank, underground sand filter, chlorinator, dechlorinator, outfall pipe,
and riprap. All flow is by gravity. All tank lids were opened for inspection.
Chuck Powell and Connor Jarvis of Pfizer assisted during the field inspection and record review.
Addition of tablets, septic tank cleanouts, and quarterly attempts (all unsuccessful) to find flow to
sample were all documented. The facility seems to have very high standards for cleanliness, safety,
and documentation.
A high TSS in 2010 was attributed to a partial outlet pipe blockage by soil.Procedures are now in place
to clean the pipe area periodically, per permittee.
DWR recommends checking the tablet status periodically between additions to be sure there is some
substance present and also running enough water to verify that flow is still active through the pipe.
R37# 2
Permit: NCG561038 Owner - Facility: Wyeth Security 6ui ding
Inspection Date: 1113l2019 Inspection Type: Compliance Eva: uaticn
Permit
(If the present permit expires in fi months or less), Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment: This system only services the -guardhouse, which is open for about one shift daily.
Visitors must check in and be escorted around the facility.
Operations & Maintenance
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters_ for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Septic Tank
(If pumps are used) Is an audible and v:sual alarm operational?
Is septic tank pumped on a schedule?
Are pumps or syphons operating properly?
Are high and low water alarms operating properly?
Yes No NA NE
❑ ❑ ■ ❑
Yes No NA NE
❑
❑
❑
❑
❑
■
❑
Yes No NA NE
Comment: The septic tank is pumped out eveN 2 years. It was done on 4/30/18 and 4130116 b
Donathan Pumping Service in Cameron. The effluent filter was reasonably clean.
Sand Filters (Low rate)
(If pumps are used) Is an audible and visible alarm Present and operational?
Is the distribution box level and watertight?
Is sand filler free of ponding?
Is the sand filter effluent re -circulated at a valid ratio?
# Is the sand filter surface free of algae or excessive vegetation?
# Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1)
Comment, The subsurface sand filter and large surrounding area are kept closely mowed.
Disinfection -Tablet
Are tablet chlorinators operational?
Are the tablets the proper size and type?
❑ ❑ ■ ❑
■ ❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ■ ❑
Yes No NA NE
Yes No NA NE
■
❑
❑
❑
❑
❑
❑
Page# 3
Permit: NCG551038 Owner - Facility: Wyeth Security Building
inspection Date: 11113/2019 Inspection Type: Compliance Evaluation
Disinfection -Tablet
Yes No NA NE
Number of tubes in use?
Is the level of chlorine residual acceptable?
❑
❑ ❑
Is the contact chamber free of growth, or sludge buildup?
0
❑ ❑
❑
Is there chlorine residual prior to de -chlorination?
❑
❑ ❑
E
Comment: Tablets are dropped in bi-weekly, per records. Sodexo Co. handles this and keeps
the
tablets elsewhere. Tablets were dissolved with only slight traces remaining, when inspected.
De -chlorination Yes No NA NE
Type of system ? Tablet
Is the feed ratio proportional to chlorine amount (1 to 1 )? 0 ❑ ❑ ❑
Is storage appropriate for cylinders? Cl ❑ 0 ❑
# Is de -chlorination substance stored away from chlorine containers? ❑ ❑ ❑ 0
Comment:
Are the tablets the proper size and type? ❑ ❑ ❑ 0
Are tablet de -chlorinators operational? M ❑ ❑ ❑
Number of tubes in use? 1
Comment: Same comments as for chlorinator tablets.
Effluent Pie
Yes No NA NE
Is right of way to the outfall properly maintained?
M
❑ ❑
❑
Are the receiving water free of foam other than trace amounts and other debris?
M
❑ ❑
❑
If effluent (diffuser pipes are required) are they operating properly?
❑
❑ M
❑
Comment: The outlet pipe and the downhill riprap were clean. The outlet area has a single
chain fence.