Loading...
HomeMy WebLinkAboutSW3191201_Supplement Form_12/5/2019SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Circle K Denver (Unity Church Rd) 2 Project Area ac 2.35 3 Coastal Wetland Area ac 0 4 Surface Water Area (ac) 0 5 Ils this project High or Low Density? High 6 1 Does this protect use an off -site SCM? No COMPLIANCE WITH 02H .1003(4) 7 Width of ve etated setbacks provided feet 10 8 Will the vegetated setback remain vegetated? Yes 9 Is BUA other that as listed in .1003 4 c-d out of the setback? Yes 10 1 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Bioretention Cell 1 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 1 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Ba filter 0 26 1 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Kai Burk, Principal 28 Organization: Bowman Consulting 29 Street address: 950 North Point Parkway, Suite 200 30 City, State, Zip: Alpharetta, GA 30005 31 Phone numbers : 678 374-6687 32 Email: kburk@bowmanconsulting.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Seal Signature of Designer Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 2 3 Is all/part of this project subject to previous rule versions? No FORMS LOADED AREA INFORMATION Entire Site 1 2 4 T pe of SCM Bioretention Sand Filter 5 Total BUA in project (sq ft 15142 sf 55918 sf 6permitting) New BUA on subdivided lots (subject to s ft 15142 sf 41833 sf 7permitting) New BUA outside of subdivided lots (subject to sf sf sf 8 Offsite - total area (sq ft sf 14085 sf 9 Offsite BUA (sq ft sf 14085 sf 10 Breakdown of new BUA outside subdivided lots: Parking (sq ft sf sf Sidewalk (sq ft sf sf Roof (sq ft sf sf Roadway s ft sf sf Future (sq ft sf sf Other, please specify in the comment box below (sq ft sf sf 11 New infiltrating permeable pavement on subdivided lots (sq ft sf sf 12 New infiltrating permeable pavement outside of subdivided lots (sq ft sf sf 13 Exisitng BUA that will remain (not subject to ermitting) (sq ft sf sf 14 Existing BUA that is already permitted (sq ft sf sf 15 Existing BUA that will be removed (sq ft sf sf 16 Percent BUA 63% 66% 17 Design storm inches 1 in 1 in 18 Design volume of SCM cu ft 1240 cf 3415 cf 19 Calculation method for design volume Simple Simple ADDITIONAL INFORMATION 20 Please use this space to provide any additional information about the drainage area(s): BIORETENTION CELL 1 1 (Drainage area number Design volume of SCM (cu ft) ERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion (10- year storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice 10 If applicable, will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC (8)? Yes 12 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes 16 1 Does the SCM follow the device specific MDC? Yes 17 lWas the SCM designed by an NC licensed professional? Yes BIORETENTION CELL MDC FROM 02H .1052 18 SHWT elevation (fmsl) 831.00 19 Bottom of the bioretention cell (fmsl) 845.00 20 Ponding depth of the design storm (inches) 1 in 21 Surface area of the bioretention cell (square feet) 1240 sf 22 Design volume of the bioretention cell (cubic feet) 1240 cf 23 Ps the bioretention cell used for peak attenuation? Yes 24 Depth of peak attenuation over planting surface (in) 846 in 25 Height of peak attenuation outlet above the planting surface (in) 2 in 26 Infiltration rate of the in situ soil (inch/hour) 27 Diameter of the underdrain pipes (if applicable) 28 Does the design include Internal Water Storage (IWS)? No 29 if so, elevation of the top of the IWS (fmsl) 30 Elevation of the planting surface (fmsl) 845 31 What type of vegetation will be planted? (grass, trees/shrubs, other)? Grass 32 Media depth (inches) 24 in 33 Percentage of medium to coarse washed sand by volume 80% 34 Percentage of fines (silt and clay) by volume 10% 35 Percentage of organic matter by volume 10% 36 Type of organic material pine bark 37 Phosphorus Index (P-Index) of media (unitless) 38 Will compaction be avoided during construction? Yes 39 Will cell be maintained to a one inch/hour standard? Yes 40 Depth of mulch, if applicable (inches) 2 in 41 Type of mulch, if applicable shredded hardwood 42 How many clean out pipes are being installed? 43 IType of pretreatment that will be used: ADDITIONAL INFORMATION71 Please use this space to provide any additional information about the 44 bioretention cell(s): 2 grass and gravel Bioretention 1 2:27 PM 11/27/2019 SAND FILTER 1 Drainage area number A 2 juesign volume of SCM (cu ft) 3415 sf 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion (10- year storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? No 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice 10 If applicable, will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC (8)? Yes 12 1 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes (SAND FILTER MDC FROM 02H _905B 18 SHWT elevation (fmsl) 831 19 Type of sand filter (open or closed) Open 20 If closed, will the filter will be pre -cast or pour -in -place? 21 If closed, top of grate elevation (fmsl) 22 Is this sand filter designed to attenuate peak flows? Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber (cubic feet) 6721 cf 24 Will there be a permanent pool in the sediment chamber? No 25 Bottom of the sediment chamber (fmsl) 844.00 26 Area of the sediment chamber (square feet) 2889 sf 27 Physical depth of the sediment chamber (inches) 48 in 28 Ponding depth in the sediment chamber, above any permanent pool (inches) 1 41 in 29 jElevation of top of weir between chambers (fmsl) 1 847.9 Sand Chamber 30 Volume that can be retained in the sand chamber (cubic feet) 13102 cf 31 Bottom of the sand chamber (fmsl) 841.50 32 Area of the sand chamber (square feet) 1683 sf 33 Physical depth of the sand chamber (inches) 48 in 34 Ponding depth in the sand chamber, above any permanent pool (inches) 41 in 35 Elevation of the bypass device (fmsl) 36 Type of bypass device 37 Mechanism for distributing flow over the sand surface underdrain 38 Sand specification for sand chamber ASTM C33 39 Depth above underdrain pipe (inches) 18 in 40 Will the media be maintained to drain at least two inches per hour at the sand surface? Yes 41 Is at least one clean -out pipe provided at the low point of each junderdrain line? Yes 42 lWill clean -out pipes be capped? Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the ISand Filter(s): Sand Filter 1 2:26 PM 11/27/2019