HomeMy WebLinkAboutNC0066516_Compliance Evaluation Inspection_20191202a
RGY COOPER
Governor
MICHAEL S. REGAN
secr-errr:
LINDA CULPEPPER
Dir a tar
NORTH CARO! ICIA
Environmental Quality
December 02, 2019
Chris Grimes, Utilities Operations Manager
Town of Fuyuay-Varina
401 Honeycutt Road
Fuyuay-Varina, NC 27526
Subject: Compliance Evaluation Inspection
Terrible Creek WWTP
NPDES Permit Number NCO066516
Wake County
Dear Mr. Grimes:
Mitch Hayes of the Raleigh Regional Office conducted the subject inspection on November 26,
20I9. The assistance of Adam Stephenson, Operator in Responsible Charge (ORC), and yourself,
back-up ORC, with this inspection was greatly appreciated. Below is a list of findings developed
from the inspection and review of the permit.
1. The subject NPDES permit was issued January 01, 2016 and expired April 30, 20I9. The
permit is currently under review. Please continue to operate under the last issued permit
until a new permit is issued.
2. The 3.0 MGD Class WW-3 WWTP consists of the following units: three (3) EQ basins;
influent pump station with six (6) pumps; mechanical coarse bar screens; 1l4- inch
mechanical bar screens; grit cyclone and classifier; two (2) five -stage conventional BNR
basins; two (2) secondary clarifiers; RAS pump station; two (2) Leopold Ultrascreen disk
style filtration units; two (2) UV disinfection channels, each with two service and one
redundant bank of UV lamps; ultrasonic effluent flow meter; cascade aeration; WAS pump
station; one (1) aerated sludge holding tank; gravity belt thickeners; two (2) three belt filter
presses; truck loading facility for off -site composting.
3. At the time of inspection, all units were in operation. The three EQ basins were empty. All
six influent pumps were in operation. Screenings and grit are conveyed to a dumpster to be
landfilled. The color of the influent in the BNR reaeration zone appeared to be chocolate
brown. There was no foaming. Caustic is being fed to reduce total phosphorus. Weirs in
both secondary clarifiers were clean with no obstruction. Effluent flowing off the weirs
appeared clear. Sludge blanket depths in both secondary clarifiers were one foot. Both UV
channels were in operation. Effluent flowing in the UV channels and at the outfall appeared
clear with no foaming. Gravity belt thickeners and the belt filter presses were in operation.
Sludge was being dewatered and loaded onto a tractor trailer truck.
�L3 ( ;:
4 � s
N::rth Caro ina Department cf Environmental Quality Div son of Water Resources Raleigh Reg onal office
3800 Barrett Drive 1628 Nla I Service Center I Raleigh, North Carolina 27699.1628
4. Discharge Monitoring Reports for the review period February 2018 through September
2019 for compliance with pen -nit limits and monitoring requirements. The following are
noted: Enforcement case MV-2018-0013 for Quarterly monitoring violations for Total
Zinc and Total Copper for March 2018. This case is still open. Enforcement case LV-2018-
0211 for ammonia nitrogen monthly average violation for April 2018. This case is closed.
Enforcement case LV-2018-0236 for monthly and weekly ammonia nitrogen violations for
May 2018. This case is closed. Enforcement case LV-2018-0299 for BOD weekly
violation, exceeding permit flow limit, and exceeding weekly ammonia nitrogen limit for
June 2018. This case is still open.
5. Commercial lab results, chain of custody records, and bench sheets were compared with
data submitted on the Discharge Monitoring Report (DMR) for the month of September
2019. No discrepancies were noted.
I would like to thank you and Adam Stephenson for you time and assistance with this inspection.
If you have any questions about this letter or the inspection, please contact Mitch Hayes at
919.791.4261 or at mitch.haveski ncdenr.,-!ov .
Sincerely,
PcotteVinson,Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NC DEQ
cc: Permit files, Laserfiche
North Carolina Departirentof Env ronmental Quality Division of Water Resources
512 North Salisbury Street 1617 Mail Service Center Rale gh, North Carolina 27699.1617
010 7n7 onnn
United States Environmental Protection Agency
Form Approved.
EPA
Washington, D C 204W CMG No. 2040-0057
Water Compliance Inspection Report I Approval expires8-31-98
Section A: National Data System Coding (i.e.. PCS)
Transaction Code NPDES yr.'malday Inspection Type Inspector Fac Type
1 u 2 15 I 3 NC0066516 11 12 19/11/26 17 18 I I 19 LJ I c I 20 I__I
I
21 � IJ 6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 CA Reserved
67 70 1, ' 71 I + 72 � �, I 73 L t f 74 75M I I I I 80
u Section 8 Facility Data LJ I I
Name and Location of Facility Inspected (For Industrial Users discharging to POTW. also include E,-try Time; Date Permit Effective Date
POTW name and NPDES permit Numberl
10 00AM 19;11+26 16101;01
Terrible Creek VWViP
NCSR 2751 Hilltop Rd Exit T-me;Date Permit Expiration Date
Fuquay Varina NC 27526 11 4EAM 19; 11-26 19104.-30
Name(s) of Onsite Representative(s)lTides(SyPhone and Fax Number(s) Other Facd ty Data
u1
Adam Parker Stephenson/ORCl1
Chris E GdmestORC1919-753-10131
Chris E Grimes/Superintendent UtiGGes1919-753-10131
Name, Address of Responsible Officialffitle/Phone and Fax Number
Adam Mitchell 401 Old Honeycutt Rd Fuquay Varina NC Contacted
27526!l919-552-140119195527481 No
Section C Areas Evaluated Dur ng Inspection (Check only those areas evaluated)
Permit EFlow Measurement E Operalons & Maintenance 0 Records/Reports
Self -Monitoring Program N Sludge Handling Disposal a Facitly Site Rev.ew N EffluenUReceiving waters
Section D. Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signalure(s) of Inspector(s) Agency-Office/Phone and Fax Numbers Date
Mitchell S Hayes DWRIRRO W01919-791.4200/
/2 r 62- z 0/
Signatur�,of Manageme O A Reviewer AgencyrOH,ce,Phane and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete
page#
NPDES yrlmalday Inspection Type (Cant.)
31 Hcoor!L 11 12 19l11 26 17 18 u
Section D Summary of FindinglComments (Attach additional sheets of narrative and checklists as necessary)
The subject NPDES permit was issued January 01, 2016 and expired April 30, 2019. The permit is
currently under review.
The 3.0 MGD Class WW 3 WWTP consists of the following units: three (3) EQ basins; influent pump
station with six (6) pumps; mechanical coarse bar screens; 114- inch mechanical bar screens; grit
cyclone and classifier; two (2) five -stage conventional BNR basins; two (2) secondary clarifiers; RAS
pump station; two (2) Leopold Ultrascreen disk style filtration units; two (2) UV disinfection channels,
each with two service and one redundant bank of UV lamps; ultrasonic effluent flow meter; cascade
aeration; WAS pump station; one (1) aerated sludge holding tank; gravity belt thickeners; two (2) three
belt filter presses; truck loading facility for off -site composting.
At the time of inspection, all units were in operation. The three EQ basins were empty. All six influent
pumps were in operation. Screenings and grit are conveyed to a dumpster to be landfilled. The color of
the influent in the BNR reaeralion zone appeared to be chocolate brown. There was no foaming.
Caustic is being fed to reduce total phosphorus. Weirs in both secondary clarifiers were clean with no
obstruction. Effluent flowing off the weirs appeared clear. Sludge blanket depths in both secondary
clarifiers were one foot. Both UV channels were in operation. Effluent flowing in the UV channels and at
the outfall appeared clear with no foaming. Gravity belt thickeners and the belt filter presses were in
operation. Sludge was being dewatered and loaded onto a tractor trailer truck.
Discharge Monitoring Reports for the review period February 2018 through September 2019 for
compliance with permit limits and monitoring requirements. The following are noted: Enforcement case
MV-2018-0013 for Quarterly monitoring violations for Total Zinc and Total Copper for March 2018. This
case is still open. Enforcement case LV-2018-0211 for ammonia nitrogen monthly average violation for
April 2018. This case is closed. Enforcement case LV-2018-0236 for monthly and weekly ammonia
nitrogen violations for May 2018. This case is closed. Enforcement case LV-2018-0299 for BOO
weekly violation, exceeding permit flow limit, and exceeding weekly ammonia nitrogen limit for June
2018. This case is still open.
Commercial lab results, chain of custody records, and bench sheets were compared with data
submitted on the Discharge Monitoring Report (OMR) for the month of September 2019. No
discrepancies were noted.
Page#
Permit NCO066516 Owner -Facility: Temble Creek WVVTP
Inspection Date: 1112612019 Inspection Type: Compl ante Eva cation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? M❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable M ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Permit
Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
❑
❑
❑
application?
Is the facility as described in the permit?
❑
❑
❑
# Are there any special conditions for the permit?
❑
❑
❑
Is access to the plant site restricted to the general public?
❑
❑
❑
Is the inspector granted access to all areas for inspection?
0❑
❑
❑
Comment: Permit exnired April 30, 2019
Record Keeping
Yes No NA NE
Are records kept and maintained as required by the permit?
0
❑
❑
❑
Is all required information readily available, complete and current?
0
❑
❑
❑
Are at] records maintained for 3 years (lab. reg. required 5 years)?
M
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
0❑
❑
❑
Is the chain -of -custody complete?
0
❑
❑
❑
Dates, times and location of sampling
■
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWO?
M
❑
❑
❑
(If the facility is = or n 5 MGD permitted flow) Do they operate 2V7 with a certified operator
❑
❑
0
❑
on each shift?
Is the ORC visitation log available and current?
0❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
M
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification?
0
❑
❑
❑
Is a copy of the current NPDES permit available on site?
0
❑
❑
❑
Page# 3
Permit: NC0066516 Owner • Faclllty: Temble Creek VNNTP
Inspection Date: 11126/2019 Inspection Type: Compliance Evaluation
Record Keeping Yes No NA NE
Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ❑
Comment:
Flow Measurement - Influent
Yes No NA NE
# Is flow meter used for reporting?
❑
0
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
0
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
N
❑
❑
❑
Comment: Effluent meter is used for reporting.
Flow Measurement - Effluent
Yes No NA NE
# Is flow meter used for reporting?
0
❑
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
❑
Comment:
Aerobic Digester
Yes No NA NE
Is the capacity adequate?
❑
❑
❑
Is the mixing adequate?
❑
❑
❑
Is the site free of excessive foaming in the tank?
M
❑
❑
❑
# is the odor acceptable?
M
❑
❑
❑
# Is tankage available for properly waste sludge?
M
❑
❑
❑
Comment: WWTP has two (2) five -stage conventional BNR basins.
Solids Handling Eciuipment
Yes No NA NE
Is the equipment operational?
0
❑
❑
❑
Is the chemical feed equipment operational?
0
❑
❑
❑
Is storage adequate?
M
❑
❑
❑
Is the site free of high level of solids in filtrate from filter presses or vacuum filters?
M
❑
❑
❑
Is the site free of sludge buildup on belts and/or rollers of filter press?
■
❑
❑
❑
Is the site free of excessive moisture in belt filter press sludge cake?
❑
❑
❑
The facility has an approved sludge management plan?
❑
❑
❑
Page# 4
Permit NC0066516 Owner • Facility: temble Creek WWTP
Inspection Date: 1112612019 Inspection Type: Compliance Evaluation
Solids Handling Equipment
Yes No NA NE
Comment: Sludge island applied by McGill Environmental System of NC under permit W00006816.
Chemical Feed
Yes No NA NE
Is containment adequate?
0❑
❑
El
Is storage adequate?
M ❑
Are backup pumps available?
11❑
Is the site free of excessive leaking?
11❑
Comment: Caustic is fed to reduce TP.
Pump Station - Influent
Yes No NA NE
Is the pump wet well free of bypass lines or structures?
Is the wet well free of excessive grease?
Are all pumps present?
Are all pumps operable?
El
0
Are float controls operable?
Is SCADA telemetry available and operational?
0
L1
[]
11
Is audible and visual alarm available and operational?
Comment:
Bar Screens
Yes No NA NE
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
❑
El
11
Is disposal of screening in compliance?
M
El
11
El
Is the unit in good condition?
Comment:
Grit Removal
Yes No NA NE
Type of grit removal
a.Manual
b.Mechanical
Page# 5
Permit: NCO066516
Owner • Facility: Temble Creek V VVrP
Inspection Date: 1112W2019
Inspection Type: Compliance Evaluation
Grit Removal
Yes No NA NE
Is the grit free of excessive organic matter?
M
Cl
❑
❑
Is the grit free of excessive odor?
M❑
❑
❑
# Is disposal of grit in compliance?
M
❑
❑
❑
Comment:
SecondaLy Clarifier
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
M
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
0
❑
❑
❑
Are weirs level?
M
❑
❑
❑
Is the site free of weir blockage?
❑
❑
❑
Is the site free of evidence of short-circuiting?
i
❑
❑
❑
Is scum removal adequate?
❑
❑
❑
Is the site free of excessive floating sludge?
M
❑
❑
❑
Is the drive unit operational?
0
❑
❑
❑
Is the return rate acceptable (low turbulence)?
0
❑
❑
❑
Is the overflow clear of excessive solids/pin floc?
M
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately %. of the sidewall depth)
0
❑
❑
❑
Comment: Sludge blanket in both clarifiers was one foot.
Equalization Basins
Yes No NA NE
Is the basin aerated?
M
❑
❑
❑
1s the basin free of bypass lines or structures to the natural environment?
■
❑
❑
❑
Is the basin free of excessive grease?
N
❑
❑
❑
Are all pumps present?
M
❑
❑
❑
Are all pumps operable?
M
❑
❑
❑
Are float controls operable?
0
❑
❑
❑
Are audible and visual alarms operable?
❑
❑
❑
# Is basin sizelvolume adequate?
❑
❑
❑
Comment: All 3 EQ basins were empty at the time of inspection.
Nutrient Removal Yes No NA NE
# Is total nitrogen removal required? M ❑ ❑ ❑
# Is total phosphorous removal required? 0 ❑ ❑ ❑
Page# 6
Permit: NCO066516 Owner - Facility: Terrible Creek wwTP
Inspection Dale. 11/2612019 Inspection type: Compliance Evaluation
Nutrient Removal Yes No NA NE
Type Biological
# Is chemical feed required to sustain process? ❑ 0 ❑ ❑
Is nutrient removal process operating properly? M❑ ❑ ❑
Comment: Caustic feed is used to reduce TP.
Filtration (High Rate Tertiary)
Yes No NA NE
Type of operation:
Cross pow
Is the filter media present?
M❑
❑
❑
Is the filter surface free of clogging?
M ❑
❑
❑
Is the fitter free of growth?
0 ❑
❑
❑
Is the air scour operational?
N❑
❑
❑
Is the scouring acceptable?
M ❑
❑
❑
Is the clear well free of excessive solids and filter media?
M ❑
❑
❑
Comment: WWTP utilizes 2-Leopold Ultrascreen disk style filtration units. Each filter unit consists of
stainless steel mesh media mounted on circular disks
Disinfection - UV
Yes No NA NE
Are extra UV bulbs available on site?
N❑
❑
❑
Are UV bulbs clean?
0❑
❑
❑
Is UV intensity adequate?
0❑
❑
❑
Is transmittance at or above designed level?
❑
❑
❑
Is there a backup system on site?
❑
❑
❑
Is effluent clear and free of solids?
❑
❑
❑
Comment: Both UV channels were being used at the time of inspection
Standby Power
Yes No NA NE
Is automatically activated standby power available?
0
❑
❑
❑
Is the generator tested by interrupting primary power source?
0
❑
❑
❑
Is the generator tested under load?
■
❑
❑
❑
Was generator tested & operational during the inspection?
❑
0
❑
❑
Do the generator(s) have adequate capacity to operate the entire wastewater site?
M
❑
❑
❑
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
N
❑
❑
❑
Is the generator fuel level monitored?
0
❑
❑
❑
Pa90 7
Permit: NCO066516 Owner -Facility: Terrible Creek WWTP
Inspection Date: 1112612019 Inspection Type: Compliance Evaluation
Standby Power Yes No NA NE
Comment; Generator is operated under load every Monday
Pum s-RAS-WAS
Yes No NA NE
Are pumps in place?
0 ❑
❑
❑
Are pumps operational?
M ❑
❑
❑
Are there adequate spare parts and supplies on site?
0 ❑
❑
❑
Comment:
Influent Sampling
Yes No NA NE
# Is composite sampling flow proportional?
❑
M
❑
❑
Is sample collected above side streams?
i
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
0
❑
❑
❑
# is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
1s sampling performed according to the permit?
0
❑
❑
❑
Comment: sample is collected using time 1 volume base.
Effluent Sampling
Yes No NA NE
Is composite sampling flow proportional?
M
❑
❑
❑
Is sample collected below all treatment units?
N
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
M
❑
❑
❑
# 1s proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
M
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency. sampling type
M
❑
❑
❑
representative)?
Comment:
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? M ❑ ❑ ❑
Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑
If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ M ❑
Comment:
Page# 8