HomeMy WebLinkAboutWQCSD0298_Compliance Evaluation Inspection_20150618SMA.�..,. r NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary June 18, 2015 Mr. Sean Ensley U. S. Department of Justice Federal Bureau of Prisons Federal Medical Center P. 0. Box 1500 Butner, NC 27509-1500 Subject: Compliance Evaluation Inspection Federal Bureau Prisons - Butner Collection System Collection System Permit No: WQCSD0298 Granville County Dear Mr. Ensley: On June 18, 2015, Cheng Zhang of the Raleigh Regional (RRO) Office Division of Water Quality conducted a Compliance Evaluation Inspection of the subject facility. The assistance and cooperation provided by Mr. Jeff Frazier, General Foreman, and Mr. Delaney Goss, Chief of Utilities, were very helpfid and appreciated. A checklist of items is enclosed with this letter. During the inspection the following items were noted: 1.) Federal Bureau of Prisons holds a deemed sewer collection system permit in Granville County. There have been no sanitary sewage overflow (SSO) incidents from the collection system since the last inspection. 2.) The collection system includes gravity sewer lines, manholes, and one pump station, which sends sewage to South Granville Water and Sewer Authority's collection system. 3.) The facility maintains a map of the system to include locations of pipes, pump station, and manholes. 4.) The facility has developed and implemented an operation and maintenance plan which lists the frequency of system inspection (pump station), preventive maintenance schedule (right-of-way maintenance), and overflow response plan. The plan needs to be updated to reflect change of personnel. 5.) The facility has a grease education program including annual fat, oil, and grease (FOG) best management practice training (part of stormwater pollution prevention training) and FOG posters at food service areas. The five grease traps are serviced by a contractor twice per month. NCDENR Raleigh Regional Office 1620 Mail Service Center, Ralegh, North Carolina 27699-1617 Lccation: 3800 Bartell Drive, Raleigh North Carolina 27609 Phone: 919-791-42001 Fax: (919) 788.7159 An Equal Opportunity AllrmahveAcWn Employer- Made -n part with recycled paper Federal Bureau of Prisons Butner Sewer Collection System Permit No_ WQCS00298 Compliance Evaluation Insp cuo'n" 6.) The lone pump station is equipped with a mechanical bar screen and standby generator. One diesel pump was also on site for emergency use. Pump station inspection, preventive maintenance, and testing of generator, alarms, and telemetry were well documented. 7.) During the inspection, four manholes were observed, the followings were noted: • The outside wall of the manhole across Old NC 75 from the pump station needs to be re - grouted with mortar; • The first manhole on the Medical Center Outfall was totally covered with thick vegetation, which needs to be removed to make the manhole accessible; • The second manhole on the outfall was not properly seated (with loose manhole ring), and sinkhole/depression were observed around the manhole; • Excessive roots were noted in the third manhole on the outfall. It is recommended that manhole inspections be included in the annual system observation. Please respond in writing regarding Items 4 and 7 within 30 days of receipt of this letter. If you have any questions regarding the attached report or any of the findings, please contact Cheng Zhang at: (919) 791-4200 (or email: chena.zhangencdenr.gov). , incer y, army Syityv Water Qegional Supervisor Raleigh Regional Office Attachments: Compliance Inspection Report Cc: Central Files wlattachment Raleigh Regional Office Wattachment t Permit: WOCSDO298 SOC: County: Granville Region: Raleigh Contact Person: Sean Ensley Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): Compliance Inspection Report Effective: 03/01/00 Expiration: Owner: Federal Bureau of Prisons Effective: Expiration: Facility: Federal Bureau Of Prisons -But On -Site Representative(s): '.J-e-fie Related Permits: Title: Certification: (rr-s►r z ; P.f--� Phone: 919-575-3900 Ext.6348 Phone: Inspection Date: 06/18/2015 Entry Time: 09'00AM Exit Time: 10.00AM Primary Inspector. Chang Zhang t�`j.�..ti Phone: 919-791-4200 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Deemed permitted collection system management and operation Facility Status: Compliant Not Compliant Question Areas: Miscellaneous Questions N Performance Standards Operation & Maint Regmis Records E Inspections Pump Station Manhole (See attachment summary) Page: 1 permit: WOCSD0298 Owner- Facility: Federal Bureau of Prisons Inspection Date: 0611812015 Inspection Type: Collection System inspect Non Samp ing Reason for Visit: Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? 0 ❑ ❑ ❑ What educational tools are used? Grease educational signs frosted at food preparation areas. Five grease traps are cleaned by contractor tw+ce per month. Is Sewer Use OrdinancelLegal Authority available? ❑ ❑ M ❑ Does it appear that the Sewer Use Ordinance is enforced? ❑ ❑ M ❑ Is Grease Trap Ordinance available? ❑ ❑ 0 ❑ Is Septic Tank Ordinance available (as applicable, i.e. annexation) ❑ ❑ ❑ List enforcement actions by permittee, if any, in the last 12 months Has an acceptable Capital Improvement Plan (CIP) been implemented? ❑ ❑ 0 ❑ Does CIP address short term needs and long term 1 master plan%" concepts? ❑ ❑ M ❑ Does CIP cover three to five year period? ❑ ❑ 0 ❑ Does CIP include Goal Statement? ❑ ❑ 0 ❑ Does CIP include description of project area? ❑ ❑ M ❑ Does CIP Include description of existing facilities? ❑ ❑ M ❑ Does CIP include known deficiencies? ❑ ❑ ■ ❑ Does CIP include forecasted future needs? ❑ ❑ M ❑ Is CIP designated only for wastewater collection and treatment? ❑ ❑ 0 ❑ Approximate capital Improvement budget for collection system? Total annual revenue for wastewater collection and treatment? CIP Comments Not required. Is system free of known points of bypass? M ❑ ❑ ❑ If no, describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? M ❑ ❑ ❑ # Does the sign include: Instructions for notification? M ❑ ❑ ❑ Pump station identifier? 0 ❑ ❑ ❑ 24-hour contact numbers 0 ❑ ❑ ❑ If no, list deficient pump stations # Do ALL pump stations have an "auto polling" featurelSCADA? ❑ M ❑ ❑ Number of pump stations t Number of pump stations that have SCADA 0 Number of pump stations that have simple telemetry 1 Number of pump stations that have only audible and visual alarms 0 Page: 3 • Permit: VVQCSD0298 Owner- Facility:Federa, Bureau of Prisons Inspection Date: 06118/2015 Inspection Type : Collection System Inspect Non Sampl mg Reason for Vish: Routine Number of pump stations that do not meet permit requirements 0 # Does the permittee have a root control program? # If yes, date implemented? Describe: Root control is conducted by facility crew. Comment: Inspections Yes No -NA NE Are maintenance records for sewer lines available? Are records available that document pump station inspections? Are SCADA or telemetry equipped pump stations inspected at least once a week? �] Are non-SCADARelemetry equipped pump stations Inspected every day? 1:1 ■ ❑ Are records available that document citizen complaints? El❑ E # Do you have a system to conduct an annual observation of entire system? ❑ 1:1 El # Has there been an observation of remote areas in the last year? ❑ Are records available that document Inspections of high -priority lines? ❑ E ❑ Has there been visual Inspections of high -priority lines in last six months? ❑ ❑ E 11 Comment: The system does not have high-priorlity lines. Operation & Maintenance Reguirements Yes No NA NE Are all log books available? arm ■ ❑ Does supervisor review all log books on a regular basis? E ❑ ❑ Does the supervisor have plans to address docUmented short-term problem areas? El ❑ E ❑ What Is the schedule for reviewing Inspection, maintenance, & operations logs and problem areas? Weekly. Are maintenance records for equipment available? E El El 0 Is a schedule maintained for testing emergencylstandby equipment? ❑ What is the schedule for testing emergencyistandby equipment? Monthly Do pump station logs include: Inside and outside cleaning and debris removal? E ❑ ❑ 11 Inspecting and exercising all valves? ❑ ❑ 11 Inspecting and lubricating pumps and other equipment? 11 Inspecting alarms, telemetry and auxiliary equipment? rl Is there at least one spare pump for each pump station Wo pump reliability? Are maintenance records for right-of-ways available? 0 Are right-of-ways currently accessible in the event of an emergency? Are system cleaning records available? ❑ Has at least 10% of system been cleaned annually? ❑ Page: A JGUME permit: WOCSDO298 Owner - Facility: Federal Bureau of Prisons Inspection Date: 06118/2015 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine What areas are scheduled for cleaning in the next 12 months? Line cleaning has been conducted since the last inspection. Due to the high flow in the system, line cleaning does not appear to be needed. Is a Spill Response Action Plan available? [] ❑ ❑ Does the plan include: 24-hour contact numbers ❑ ❑ [] Response time N ❑ ❑ ❑ Equipment list and spare parts inventory N ❑ 0 ❑ Access to cleaning equipment E ❑ [] ❑ Access to construction crews, contractors, and/or engineers 0 ❑ ❑ ❑ Source of emergency funds E ❑ ❑ ❑ Site sanitation and cleanup materials E ❑ ❑ ❑ Post-overflow/spill assessment ■ ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? N ❑ ❑ ❑ Is the spare parts inventory adequate? N ❑ ❑ ❑ Comment: The plan needed to be undated due to personnel change. Records Yes No NA NE Are adequate records of all SSOs, spills and complaints available? ❑ ❑ ❑ Are records of SSOs that are under the reportable threshold available? ❑ ❑ ❑ Do spill records indicate repeated overflows (2 or more in 12 months) at same location? ❑ ❑ ❑ If yes, is there a corrective action plan? [� ❑ ❑ Is a map of the system available? ❑ ❑ ❑ Does the map Include: Pipe sizes ❑0 0 ❑ Pipe materials ❑ ■ ❑ ❑ Pipe location N ❑ ❑ ❑ Flow direction ❑ ■ ❑ ❑ Approximate pipe age ❑ ❑ ❑ Number of service taps ❑ ❑ ❑ Pump stations and capacity N 0 ❑ ❑ If no, what percent is complete? List any modifications and extensions that need to be added to the map The map shows locations of sewer lines, manholes, and pump station. # Does the permittee have a copy of their permit? ❑ ❑ Comment: Deemed permitted. MANHOLE #1 - On other sic Manhole Yes No NA NE Page: 5 • permit. WOCS00298 Owner - Facility: Federal Bureau of Prisons Inspactlon Gate: 06I1612015 Inspection Type: collection System Inspect Non Sampling Reason for Visit: Routine Is manhole accessible? ■ ❑ ❑ ❑ # Is manhole coverlvent above grade? 0 ❑ ❑ ❑ Is the manhole free of visible signs of overflow? E ❑ ❑ ❑ Is the manhole free of sinkholes and depressions? 0 ❑ ❑ ❑ Is manhole cover present? 0 ❑ ❑ ❑ # Is manhole properly seated? 0 ❑ ❑ ❑ # Is manhole in good condition? ❑ N ❑ ❑ # Is Invert in good condition? 0 Cl ❑ Cl Is line free -flowing and unrestricted in manhole? N ❑ Cl Cl Is manhole free of excessive amounts of grease? 0 ❑ ❑ ❑ Is manhole free of excessive roots? 0 ❑ ❑ ❑ Is manhole free of excessive sand? E ❑ ❑ ❑ Is manhole's extended vent screened? ❑ ❑ E ❑ Are vents free of submergence? ❑ ❑ ❑ Are manholes free of bypass structures or pipes? ❑ ❑ ❑ Comment: The outside wall of the manhole needs to be re -grouted with mortar. MANHOLE #2 - Medical Cer Manhole Yes No NA NE Is manhole accessible? ❑ E ❑ ❑ # Is manhole covertvent above grade? N ❑ ❑ ❑ Is the manhole free of visible signs of overflow? N ❑ ❑ ❑ Is the manhole free of sinkholes and depressions? ❑ ❑ ❑ Is manhole cover present? ❑ ❑ ❑ # Is manhole properly seated? 0 ❑ ❑ ❑ # Is manhole In good condition? ❑ ❑ ❑ # Is invert in good condition? ❑ ❑ ❑ 0 Is line free -flowing and unrestricted in manhole? ❑ ❑ ❑ Is manhole free of excessive amounts of grease? ❑ ❑ ❑ Is manhole free of excessive roots? ❑ ❑ ❑ Is manhole free of excessive sand? ❑ ❑ ❑ Is manhole's extended vent screened? ❑ ❑ E ❑ Are vents free of submergence? ❑ ❑ ❑ ■ Are manholes free of bypass structures or pipes? ❑ ❑ ❑ Comment: The above ground part of the manhole is totally covered by thick vegetation. MANHOLE # 3 - Medical Ce Manhole Yes No NA NE Page: 6 permit WOCS00298 owner - Facility: Federal Bureau of Prisons Inspection Oats: 06/18/2015 Inspectlon Type: Collection System Inspect Non 5ampltng Reason for Visit Routine Is manhole accessible? ❑ # Is manhole cover/vent above grade? ❑ Is the manhole free of visible signs of overflow? ❑ Is the manhole free of sinkholes and depressions? Is manhole cover present? 0 ❑ ❑ # Is manhole properly seated? # Is manhole in good condition? ❑ # Is Invert in good condition? El El 00 Is line free -flowing and unrestricted in manhole? El [] E Is manhole free of excessive amounts of grease? ❑ Is manhole free of excessive roots? [, El E Is manhole free of excessive sand? Is manhole's extended vent screened? 11 [] Are vents free of submergence? []11 E Are manholes free of bypass structures or pipes? [l Comment: Sinkholeldeoression observed around the manhole. Manhole ring was loose, cover could not be opened. MANHOLE #4 - Medical Cei Manhole Yea No NA NE Is manhole accessible? 0 [1 ❑ ❑ # Is manhole cover/vent above grade? E C1 ❑ ❑ Is the manhole free of visible signs of overflow? ❑ 11 ❑ Is the manhole free of sinkholes and depressions? ri ❑ ❑ Is manhole cover present? C ❑ ❑ # Is manhole properly seated? E ❑ El # Is manhole in good condition? # Is invert In good condition? Is line free -flowing and unrestricted in manhole? D ❑ Is manhole free of excessive amounts of grease? Is manhole free of excessive roots? 0❑ ❑ Is manhole free of excessive sand? 0El❑ ❑ Is manhole's extended vent screened? 11 Are vents free of submergence? �] Are manholes free of bypass structures or pipes? ❑ ❑ ❑ Comment: Excessive roots were noted in the manhole. Flow was good and unrestricted. PUMP STATION - Page: 7 • Permit: WOCSDO298 Owner - Facility: Federal Bureau of Prisons Inspection Date: 061t6 GIS Inspection Type. Collection System Inspect Non Sampling Reason for Visit: Routine PUMP Staftn Yes No NA NE Pump station type Duplex Are pump station logs available? E ❑ ❑ ri Is it accessible in all weather conditions? 11 ❑ El # Is general housekeeping acceptable? 11❑ Are all pumps present? Are all pumps operable? Are wet wells free of excessive debris? Are upstream manholes free of excessive debrislsigns of overflow? 0 ❑ Are floats/controls for pumpslalarms operable? ❑ 0 El Is "auto polling" featurelSCADA present? [] ❑ Is "auto polling" featurelSCADA operational? El Is simple telemetry present? ri Is simple telemetry operational? m❑ Are audio and visual alarms present? Are audio and visual alarms operable? ❑ Is the Pump station Inspected as required? 11❑ Are backflow devices in place? ❑ ❑ ❑ Are backflow devices operable? ❑ ❑ Are air relief valves in place? Are air relief valves operable? # Is an emergency generator available? 011 ❑ 13 Can the emergency generator run the pumps? ■ ❑ ❑ Is the pump station equipped for quick hook-up? El 11 0 ❑ Is the generator operable? E ❑ # Is fuel in lank and sufficient? Is the generator inspected according to their schedule? Is a 24-hour notification sign posted? Does it include: Instructions for notification? Pump station identifier? 0 El El ri Emergency phone number E El El 13 Is public access limited? 0 Is pump station free of overflow piping? Is the pump station free of signs of overflow? El Are run times comparable for multiple pumps? Yes Page: a permit• VMCS00298 Owner • Facility: Federal Bureau of Prisons Inspection Gate: 06/18/2015 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Comment: Two Gorman-RUDD Pumos. One bypass Dumo Is olaced on site, in case both pumps fail. Flow passes a mechanical bar screen before entering wet well. Page: 9