HomeMy WebLinkAboutWQ0041289_Application (FTSE)_20191125Permit Number WQ0041289
Program Category
Non -discharge
Permit Type
Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions
Primary Reviewer
dean.hunkele
Coastal SWRule
Permitted Flow
Facility Name
Shallotte 12 inch WWTP Forcemain Sewer
Location Address
Owner
Central Files: APS _ SWP _
11/6/2019
Permit Tracking Slip
Status
Project Type
In review
New Project
Version
Permit Classification
A
Individual
Permit Contact Affiliation
Major/Minor Region
Minor Wilmington
County
Brunswick
Facility Contact Affiliation
Owner Name Owner Type
Town of Shallotte Government - Municipal
Owner Affiliation
Walter Eccard
PO Box 2287
Dates/Events Shallotte NC 28459228
Scheduled
Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration
11/4/2019
DAVID B. BOWMAN, PE
1010 Central Avenue, Burlington, NC 27215
Phone: 910-443-2082 Email: dbowman@atmc.net
October 27, 2019
Mr. Dean Hunkele
Water Quality Section
NCDEQ
127 Cardinal Drive Ext.
Wilmington, North Carolina 28405
Subject: Town of Shallotte- 12" WWTP Force Main
Dear Mr. Hunkele:
As you are probably aware, the Town of Shallotte has an existing 8" force main that runs into the
west side of the WWTP and carries most of the flow from the Town. In order to reduce the
significant pressures in that single 8" line, the Town is proposing a new 12" sewer force main that
will parallel the existing 8" line. This new 12" force main will tie into the existing 8" line just
upstream of the 6" force main that crosses US Highway 17 from Mulberry Street. All of the flow
south of Mulberry Street will thus be routed into the new 12" force main. This new line will run
parallel to the existing 8" line, up Mulberry Street Extension, and across the WWTP site to the
existing flow meters at the WWTP. There will be no new flow into the WWTP, just a more
efficient handling of the existing flow.
Enclosed please find the following:
An original and a copy of the Fast Track Application (FTA 04-16),
2. A check for $480,
3. A site map showing the location of the proposed sewer.
Should you require any additional information, or have any comments, please call or
email. Thanks.
Sincerely,
David B. Bowman, P.E.
RECgk11[DJ1M0ENRIDWR
NOV 0 4 Z019
Water (Quality iiegionai
pperations Section
W1lniin2h,.
State of North Carolina
DWR Department of Environmental Quality
Division of Water Resources
15A NCAC 02T .0300— FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
Ulvlslon of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION
Application Number: gq__._-.-_— (to be completed by DW It)
All items must be conudeted or the application will be returned
1. APPLICANT INFORMATION:
I. Applicant's name: Town of Shallotte (company, municipality, IICA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership
❑ Federal ❑ State/County ® Municipal
3. Signature authority's name: Mimi Gaither per 15A NCAC 02.1'.0106(b)
Title: Town Administrator
4. Applicant's mailing address: 110 Box 2287
City: Shallotte State: NC Zip: 28459-_
5. Applicant's contact information:
Phone number: (910) 754-4032 Email Address: m aithciOiownofshallotte.org
❑ Privately -Owned Public Utility
❑ Other
11. PROJECT INFORMATION:
I. Project name: Shallotte 12" WWTP Forcemain 5eWei
2. Application/Project status: ® Proposed (New Permit) ❑ Existing Pennit/Project
If a modification, provide the existing permit number: WQ00___ and issued date:
If new construction but part of a master plan, provide the existing permit number: WQ00_
3. County where project is located: Brunswick
4. Approximate Coordinates (Decimal Degrees): Latitucle: 33.992'" Longitude: -78.394`
5. Parcel ID(ifapplicable): IS100072
(or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
I. Professional Engineer: David B. Bowman, PE License Number: 16729
Firm: David B. Bowman, PE
Mailing address: 1010 Central Ave
City: Burlington Slate: NC Zip: 27215-_
Phone number: (910) 443.2082 Email Address: dbowmaiQatmc.net
IV. WASTEWATERTREATMENT FACILITY (WWTF) INFORMATION:
I. Facility Name: Shallotte W W2P Permit Number: W00000798
Owner Name: Brunswick County
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different Ihan WWTF):
I. Permit Number(s): WQ_ Downstream (Receiving) Sewer Size: inch
System Wicle Collection Salem Permit Numbers) (ifap licable : WQCS
Owner Name(s): Brunswick County
FORM: FTA 04-16 Page I of5
VI. GENERAL REQUIREMENTS
I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑No ®N/A
2. If the Applicant is it Developer of lots to be sold, has a Developer's Operational Aereement (FORM: DEV) been attached?
❑ Yes ❑No ®N/A
3. If the Applicant is a Home/Property Owners' Association has an Operational Aereement (FORM: HUA) been attached?
❑ Yes ❑No ®N/A
4. Origin of wastewater: (check all that apply):
❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing f tonic ❑ Other (Explain in Attachment)
5. Nature of wastewater: % Domestic/Commercial % Conin ercial
_ % Industrial (See 15A NCAC 02T .0103(20))
Is there a Pretreatment Program in effect? ❑ Yes ❑ No
6. Has a flow reduction been approved under 15A NCAC 02T .01 14(f)? ❑ Yes ❑ No
r If ves, provide a cony of flow reduction apnroval letter
7. Stunntarize wasle%vater generated by project:
Establishment Type (see 02T.0114H))
Daily Design Flow "'s
No. of Units
Flow
gal/
GPD
gal/
GPD
gal/
GPD
---gal/ --
GPD
gal/
GPD
gau
GPD
Tom/
GPD
a See 15A NCAC 02 f .0114(b) (d). (e)(1) and (c)(2) for caveats to wastewater design flow rates (i.e., minimum Flow per
dwelliug: proposed unknown non-residential development uses; public access facilities located near high public use
areas; and residential properly located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals
as defined in C,S. 42A=4).
b Per 15A NCAC OTT .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T,0114] shall
be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T.0114)
7 Do not include future flows or previously pennitted allocations
If permitted Flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where Flow will be permitted in subsequent permits that connect to this line
❑ Flow has already been allocated in Permit Numbcr:
❑ Rehabilitation or replacement of existing sewer with no new now expected
® Other (Explain): This proposed 12" force main serves to reduce pressure in an existing, parallel 8" force main.
FORM: FTA 04.16 Page 2 or
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers):
1. Summarize gravity sewer to be permitted:
Size (inches) Length (feet) Material
➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains):
COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name: n/a
2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: -
3. Design flow of the pump station: millions gallons per day (firm capacity)
4. Operational point(s) of the pump(s): gallons per minute at _ feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches)
Length (feet)
Material
12
9481
SDR21 PVC
12
45
350 psi DIP
16
60
DR9 HDPE
6. Power reliability in accordance with 15A NCAC 02T .0305 h 1 :
❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T
.0305(h)(1)(C)
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C):
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement)
and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations'
storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be
provided in the case of a multiple station power outage.
FORM: FTA 04-16 Page 3 of 5
IX. SETBACKS & SEPARATIONS —(02B .0200 & 15A NCAC 02T.0305(o):
1. Does the project comply with all separations found in I SA NCAC 02T 0305(f) & (e) ® Yes [:)No
15A NCAC 02'f.0305(f) contains minimum separations that shall be Drovided for sewer systems:
Setback Parameter*
Separation Requited
Storm sewers and other utilities not listed below (vertical)
24 inches
Water mains (vertical -water over sewer including in benched trenches)
18 inches
Water mains (horizontal)
10 feet
Reclaimed water lines (vertical - reclaimed over sewer)
18 inches
Reclaimed water lines (horizontal - reclaimed over sewer)
2 feet
**Any private or public water supply source, including any wells, WS-1 waters of Class I or
Class II initiounded reservoirs used as a source of drinking water
100 feet
**Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water (or tide elevation) and wetlands (see item IX.2)
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Any building foundation
5 feet
Any basement
10 feet
Top sloe of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming Wools
10 feet
Final earth grade (vertical)
36 inches
%• ISA NCAC 02'17.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved.
**Stream classifications can be identified using the Division's NC Surface Water Classifications webs ape
Y If noncompliance with 02TA305f I) or (g)_, see Section X of this application
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ❑ N/A
See the Division's draft separation requirements for situations where separation cannot be nneet
v No variance is required if the alternative design criteria specified is utilized in design and construction
> As built documents should reference the location of areas effected
3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N/A
This would include Trout Buffered Streams per 15A NCAC 213.0202
4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No
individual permits or401 Water Quality Certifications?
Information can be obtained front the 401 & Buffer Permitting Branch
5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No
Per 15A NCAC: OZT.0105u(6), directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, storntwater management plans, etc.).
6. Does this project include any sewer collection lines that are deemed "high -priority?"
Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to sireambanks that is subject to erosion that undermines or deteriorates the sewer.
❑ Yes ® No ❑ N/A
If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permillee or its representative at least once every six-monlins and
inspections documented per 15A NCAC 021'.0403(a)(5) or the permitee's individual System -Wide Collection permit.
FORM: FfA 04.16 Page 4 of 5
X. CERTIFICATIONS:
I. Does the submitted system coiitply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains (latest version), aiid the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
® Yes ❑ No
If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents
for review. _Approval of the request is renuired prior to submittal of the Fast Track Aoolicalion and sunnorling
documents,
2. Protessional Engineer's Certification:
I, . �Qy1D__3•_IE5c;-WMAN_ fE-- _ _ attest that this application for
(Professional Engineer's name from Application Item 111.1.)
has been reviewed by nic and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering calculations, and all other supporting docuntentatiolt to the best of my knowledge. I further attest that to the best
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track
Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed ceitain
portions of this subniilml package, inclusion of these niatei ials under my signature and seal signifies that I have reviewed this
material and have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.66, any person who knowingly makes any false
slatenicnt, representation, or ceidlicalion in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
North Carolina Professional Engineer's seal, signature, and date:
Applicant's Certification per I SA NCAC 02T .0106(b):
that this application for
Authority's name & title from Application Item 1.3.)
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -
discharge system to surface waters o the land will result in an immediate enforcement action that may include civil penalties,
irjunctivc relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a
condition of this permit be violated. I also understand that if all required parts of this application package are not completed
and that if all required supporting information and attachments are not included, this application package will be returned to
nne as incomplete.
NOTE — [it accordance with General Statutes 143-215_6A and 143.215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which nnay
include a fine not to exceed $ I0,000 as well as civil penalties up to $25,000 per violation.
Signature: A"A
I ORM: FTA 04.16 Page 5 ot'S
7.5-MINUTE SERIES science for a changing world
-78.3750'
9 40 41 42 74300OmE 44 45
Good LLc Bay
T pR.
r15 17 -1
Lehew Cm E�
FR°NTAGE
ZIP
17 w N w-i
1
Pf B�
NFREE wAY S...
��� 17 a Red Bu ShWlo
1 I %g 'D I yu r t
Htii wN tE 51. ed Bug HO De IB�A� e n 4
H RD
/�- 44rkp�,w BR/OGfR RD __ .15 S �n 87
L Sh Otte'
12
+' 1
l (/\
aY a \ g9JH oR `rro,�7 Itosw'
y ` , LLERS S7' �F,Q' '... _ \� °Jh, �( LIURfls �
^v
Oi tili �
-�
PV
. '!i MAIN 51 17 �.. J _'�D,_—_.