October 31, 2019
Subject: Notice of Violation
Deemed Permitted Wastewater Collection System Inspection
Violation Tracking No. NOV-2019-PC-0725
System Number WQCSD0213
Oak Ridge Collection System
Guilford County
Dear Dr. Wilson:
On October 3, 2019, Paul DiMatteo of the Division of Water Resources (Division), Winston-Salem Regional Office
met with Brian Shreve, Director of Operations, and operations staff Tim and Brandy, to conduct Compliance Evaluation
Inspections of the above referenced Deemed Permitted Wastewater Collection System.
The inspection consists of (1) a review of documentation demonstrating compliance with 15A NCAC
02T .0403, which regulates wastewater collection systems that are not individually permitted, and (2) an on -
site inspection of several collection system components. The attached inspection form notes the areas that
were evaluated for the inspection, with notable findings outlined as follows.
Summary of Non -Compliance
1. Map - .0403(a)(2) requires a map of the collection system to be developed and maintained. Although previous
inspections noted an adequate map was available, the operations staff could not locate the map during the
inspection. Please locate the existing map or have a new map drawn.
2. Pump Station Inspections - .0403(a)(4) requires pump stations not connected to a telemetry system to be
inspected every day. There is one small pump station behind the barber shop building which is inspected
occasionally with maintenance activities documented, but it should be checked every day and those checks also
documented.
3. High Priority Line Inspections — .0403(a)(5) requires that high priority sewers be inspected every 6 months and
the inspections documented. Operators said that they see the aerial line several times per week but the
inspections are not documented.
4. General Observation - .0403(a)(6) requires a general observation of the entire collection system to be conducted
once per year and the inspections documented. Documentation of such inspections were not available during
the inspection.
D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources
Winston-Salem Regional Office 1 450 West Hanes Mill Road, Suite 300 I Winston-Salem, North Carolina 27105
Noah CaaouNA ^
n.P. MorMwL.IOWHV� 336.776.9800
5. Grease Control - .0403(a)(8)(B) requires a grease control program to be in place that includes bi-annual
distribution of grease educational materials to users of the collection system. As the only significant grease
contributor is the food hall, the inspector recommended posting signs about not pouring grease down the drain
in the kitchens.
6. Documentation - .0403(a)(10) requires documentation to be kept showing compliance with the other sections of
the Rule. As discussed above most documentation was missing.
Site Inspections
1. Pump Stations —The simplex pump station behind the barber shop area was inspected. The inspector noted
that there were no operable alarms. The pump station should have at least an operable audible and visual high
water level alarm, and the alarm should be checked periodically to ensure operation.
2. High Priority Lines —The high priority line near the wastewater treatment plant was inspected and no issues
were noted.
Requested Response
Within 30 days of receipt of this letter, please submit a plan to address the violations noted above for review.
If you should have any questions, please do not hesitate to contact Paul DiMatteo at (336) 776-9691 or our
office at (336) 776-9800.
Sincerely,
DocuSigned by:
945B49E225C94EA...
Lon T. Snider, Regional Supervisor
Water Quality Regional Operations Section
Winston-Salem Regional Office
Division of Water Resources, NCDEQ
Enclosures — Inspection Report, Copy of 15A NCAC 02T .0403
CC: DWR Laserfiche Files
Permit: WQCSD0213
SOC:
County: Guilford
Region: Winston-Salem
Contact Person: John Haynes
Directions to Facility:
System Classifications:
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Compliance Inspection Report
Effective: 03/01/00 Expiration: Owner: Oak Ridge Military Academy
Effective: Expiration: Facility: Oak Ridge Military Academy Collection System
Inspection Date: 10/03/2019
Primary Inspector: Paul DiMatteo
Secondary Inspector(s):
Title:
EntryTime: 10:OOAM
Certification:
Phone: 336-643-4131 Ext.144
Phone:
Exit Time: 11:30AM
Phone: 336-776-9691
Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling
Permit Inspection Type: Deemed permitted collection system management and operation
Facility Status: ❑ Compliant Not Compliant
Question Areas:
Miscellaneous Questions General Grease Control
Spills/Response Plan Inspections Lines
Manholes Pump Stations
(See attachment summary)
Page 1 of 6
Permit: WQCSD0213 Owner - Facility: Oak Ridge Military Academy
Inspection Date: 10/03/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
Inspection Summary:
Met with Brian Shreve, along with Tim Bullins and Brandy (last name?) to do the inspection. The primary issues are
summarized as follows:
- Pump should be checked daily and documented.
- HPL and general system inspections should be documented.
- Should have some form of grease control - we discussed posting signs in the kitchen.
Page 2 of 6
Permit: WQCSD0213 Owner - Facility: Oak Ridge Military Academy
Inspection Date: 10/03/2019 Inspection Type : Collection System Inspect Non Sampling
Reason for Visit: Routine
General
Yes No NA NE
# Is this system a satellite system?
❑
0 ❑ ❑
# If Yes, what is system name or permit number?
Is there a overall sewer system map?
❑
❑ ❑
Does the map include:
Pipe sizes
❑
❑ ❑
Pipe materials (PVC, DIP, etc)
❑
❑ ❑
Pipe location
❑
❑ ❑
# Flow direction
❑
❑ ❑
# Approximate pipe age
❑
❑ ❑
# Pump station ID, location and capacity
❑
❑ ❑
# Force main air release valve location & type
❑
❑ ❑
# Location of satellite connections
❑
❑ ❑
Are system maintenance records maintained?
❑
❑ ❑
Comment: Records - there was a loa sheet next to the seDtic tank/effluent DumD behind the barber sho
area. There were not records of other maintenance activities.
Maps - the previous inspection said that there was a map, but it was not available during this
inspection. According to operators, they had some recent turn over, and in the time since the last
inspection the old (now current) operators left and came back, so things were not well
organized.
Grease Control
Is grease/sewer education program documented with req'd customer distribution?
# Are other types of education tools used like websites, booths, special meetings, etc?
If Yes, what are they? (This can reduce mailing to annual.)
For public systems, is there a Grease Control Program via an ordinance/agreement?
If Yes, does it require grease control devices at applicable locations?
Is the Grease Control Program enforced via periodic inspections/records review?
Is action taken against violators?
Comment: The onlv maior arease contributor is the food hall. We discussed ways to aet an "education
program" together, e.g. signs or training for kitchen employees.
Spills and Response Action Plan
# Is system free of known points of bypass?
If No, describe type of bypass and location
# Have there been any sewer spills in the past 3 years?
If Yes, were they reported to the Division if meeting the reportable criteria?
If applicable, is there documentation of press releases and public notices issued?
Yes No NA NE
❑■❑❑
❑■❑❑
❑❑■❑
❑❑■❑
❑❑■❑
❑❑■❑
Yes No NA NE
■❑❑❑
❑■❑❑
❑❑■❑
❑❑■❑
Page 3 of 6
Permit: WQCSD0213 Owner - Facility: Oak Ridge Military Academy
Inspection Date: 10/03/2019 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine
Are all spills or sewer related issues/complaints documented? 0 ❑ ❑ ❑
# Are there repeated overflows/problems (2 or more in 12 months) at same location? ❑ ❑ ❑
# If Yes, is there a corrective action plan? ❑ ❑ ❑
Is a Spill Response Action Plan available? ❑ ❑ ❑
Is a Spill Response Action Plan available for all personnel? 0 ❑ ❑ ❑
Does the plan include:
# 24-hour contact numbers
0
❑ ❑ ❑
# Response time
❑ ❑ ❑
# Equipment list and spare parts inventory
❑ ❑ ❑
# Access to cleaning equipment
❑ ❑ ❑
# Access to construction crews, contractors, and/or engineers
❑ ❑ ❑
# Source of emergency funds
❑0
❑ ❑
# Site sanitation and cleanup materials
❑ ❑ ❑
# Post-overflow/spill assessment
0
❑ ❑ ❑
Comment: Spill response plan - I gave them a copy of what we had in our files during the inspection. As
previously mentioned, their own records were not well organized/not available. It should be
reviewed and updated.
Inspections
Yes No NA NE
Are adequate maintenance records maintained? ❑ ❑ ❑
Are pump stations being inspected at the required frequency? ❑ ❑ ❑
Is at least one complete functionality test conducted weekly per pump station? ❑ ❑ ❑
Is there a system or plan in place to observe the entire system annually? ❑ ❑ ❑
Is the annual inspection documented? ❑ 0 ❑ ❑
# Does the system have any high -priority lines/locations? ❑ ❑ ❑
Are inspections of HPL documented at least every 6 months? ❑ ❑ ❑
Are new lines being added to the HPL list when found or created? 0 ❑ ❑ ❑
Comment: HPL inspections are reportedly conducted but not documented.
Lines/Right-of-Ways/Aerial Lines Yes No NA NE
Please list the Lines/Right of Ways/Aerial Lines Inspected:
Main aerial line
Are right-of-ways and easements maintained for the full width for access? ❑ ❑ ❑
If No, give details on temporary access:
Is maintenance documented? ❑ ❑ ❑
Were all areas/lines inspected free of issues? N ❑ ❑ ❑
Comment: Some growth in the ROW but didn't look inaccessable. Growth should be controlled as needed.
Manholes
Yes No NA NE
Page 4 of 6
Permit: WQCSD0213 Owner - Facility: Oak Ridge Military Academy
Inspection Date: 10/03/2019 Inspection Type : Collection System Inspect Non Sampling
Reason for Visit: Routine
Please list the Manholes Inspected:
Are manholes accessible?
0
❑ ❑ ❑
# Are manhole covers/vents above grade?
0
❑ ❑ ❑
Are manholes free of visible signs of overflow?
0
❑ ❑ ❑
Are manholes free of sinkholes and depressions?
0
❑ ❑ ❑
Are manhole covers present?
0
❑ ❑ ❑
# Are manholes properly seated?
0
❑ ❑ ❑
# Are manholes in good condition?
0
❑ ❑ ❑
# Are inverts in good condition?
❑
❑ ❑
Is flow unrestricted in manholes?
❑
❑ ❑
Are manholes free of excessive amounts of grease?
❑
❑ ❑
Are manholes free of excessive roots?
❑
❑ ❑
Are manholes free of excessive sand?
❑
❑ ❑
Are manhole vents screened?
❑
❑ 0 ❑
Are vents free of submergence?
❑
❑ 0 ❑
Are manholes free of bypass structures or pipes?
❑
❑ ❑
Comment: Didn't look inside a manhole.
Pump Stations
Yes No NA NE
Please list the Pump Stations Inspected:
PS behind barber shop area
# Number of duplex or larger pump stations in system
0
# Number of vacuum stations in system
0
# Number of simplex pump stations in system
1
# Number of simplex pump stations in system serving more than one building
1
How many pump/vacuum stations have:
# A two-way "auto polling" communication system (SCADA) installed?
0
# A simple one-way telemetry/communication system (auto -dialer) installed?
0
For pump stations inspected:
Are they secure with restricted access?
❑ ❑ ❑
Were they free of by-pass structures/pipes?
❑ ❑ ❑
Were wet wells free of excessive grease/debris?
❑ ❑ ❑
# Do they all have telemetry installed?
❑
❑ ❑
Is the telemetry system functional?
❑
❑ ❑
Is a 24-hour notification sign posted ?
❑
❑ ❑
Does the sign include:
Owner Name?
❑
❑ ❑
Page 5 of 6
Permit: WQCSD0213 Owner - Facility: Oak Ridge Military Academy
Inspection Date: 10/03/2019 Inspection Type : Collection System Inspect Non Sampling
Reason for Visit: Routine
Pump station identifier?
❑
❑ 0 ❑
# Address?
❑
❑ 0 ❑
Instructions for notification?
❑
❑ 0 ❑
24-hour emergency contact numbers?
❑
❑ 0 ❑
Are audio and visual alarms present?
❑
0 ❑ ❑
Are audio and visual alarms operable?
❑
0 ❑ ❑
# Is there a backup generator or bypass pump connected?
❑
0 ❑ ❑
If tested during inspection, did it function properly?
❑
❑ ❑
Is the back-up system tested at least bi-annually under normal operating conditions?
❑
❑ ❑
# Does it have a dedicated connection for a portable generator?
❑
❑ ❑
# Is the owner relying on portable units in the event of a power outage?
❑
❑ ❑
# If Yes, is there a distribution plan?
❑
❑ ❑
If Yes, what resources (Units/Staff/Vehicles/etc) are included in Plan?
# Does Permittee have the approved percentage of replacement simplex pumps?
❑
❑ ❑
Is recordkeeping of pump station inspection and maintenance program adequate?
❑
❑ ❑
Do pump station logs include at a minimum:
Inside and outside cleaning and debris removal? ❑ ❑ ❑
Inspecting and exercising all valves? ❑ ❑ ❑
Inspecting and lubricating pumps and other equipment? ❑ ❑ ❑
Inspecting alarms, telemetry and auxiliary equipment? ❑ ❑ ❑
Comment: There was a log sheet that the operator signs whenever he looks at the pump station. We talked
about making sure to check it daily, logging it, and other requirements.
The only pump station is across the street from the main campus. It used to serve 5 buildings
but now only the barber shop is in use, it gets very little flow.
Page 6 of 6