Loading...
HomeMy WebLinkAboutNCG070189_COMPLETE FILE - HISTORICAL_20180205STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /V DOC TYPE Y'H ISTORICAL FILE ❑ MONITORING REPORTS DOC DATE YYYYMMDD fi Lr Energy, Mineral and Land Resources ENVIRONMENTAL QUALITY February 5, 2018 Stephen R. Phelps Allura Plycem USA, Inc. 1149 Abtco Road N. Wilkesboro, NC 28659 ROY COOPER Governor MICHAEL S. REGAN Secretary WILLIAM E. VINSON, JR. Interim Director Subject: Complaint Investigation & Compliance Inspection Permit No. NCG 079-M- o �6169 Allura Plycem USA, Inc. Wilkes County Dear Mr. Phelps: On February 1, 2018, Glen White & Sue White, inspectors with the North Carolina Department of Environmental Quality - Division of Energy, Minerals and Land Resources met with you and Kim Burton (EHS Manager) at the facility located at 1149 Abtco Road in North Wilkesboro, to conduct a compliance inspection as part of a complaint investigation received by the Division of Water Resources permit. This inspection consists of review of the Stormwater Pollution Prevention Plan (SPPP) and each of its components, review of Monitoring Records as well as review of the facilities outfalls, containment facilities as well as review of the overall condition of the site. The complaint alleged that waste product materials were discharging from the facility and were entering and contaminating the Yadkin River. Complaint also suggest that the facilities storage areas exposed to the elements were poorly maintained. The housekeeping issues were verified. No evidence of discharge to the Yadkin River could be identified. Permit: This facility holds General Stormwater Permit NCG070189 to discharge stormwater from industrial activity associated with Stone, Clay, Glass and Concrete Products [SIC 321 under the National Pollutant Discharge Elimination System (NPDES). The permit became effective June 1, 2013 and is scheduled to expire on May 31, 2018. The facility will remain covered under the permit, even after expiration, until the new general permit is issued by the Stormwater Permitting Unit in the Raleigh Central Offices. Records/Reports: This facility was required to develop and maintain a Stormwater Pollution Prevention Plan (SPPP) in accordance with Part II, Section A of the permit. All qualitative monitoring records are required to be maintained with the SPPP for a minimum of five (5) years. Under this permit, no analytical monitoring is required under current operating procedures. The facility records currently appear to meet requirements of the permit. State of North Carolina � Environmental Quality I Energy, Mineral and Land Resources Winston-Salem Regional Office j 450 Hanes Mill Road, Suite 300 1 Winston-Salem, NC 27103 336-776-9800 Facility Site Review: This facility manufactures siding used in commercial and residential applications. Product, ready to be shipped, is wrapped in plastic to protect it from the elements, and it is stored outside and behind the building. Effluent Receiving Waters: Effluent from this facility drains directly into the adjacent Yadkin River, class "C" waters of the Yadkin Pee -Dee River Basin. Self -Monitoring Program: This facility is required to provide Qualitative Monitoring twice annually. No Analytical Monitoring is required under current operating procedures. While this facility was found to be compliant with the requirements of its General Stormwater Permit (NCGO70189), several deficiencies were found. The following determination and recommendations were made by DEMLR Staff: This facility is covered under the NCG070189 Stormwater Permit. The permit only requires Qualitative Monitoring under current operating procedures. DEMLR does reserve the right to modify this requirement and may require Allura to begin providing Analytical Monitoring or to obtain a more restrictive Individual Permit if the issues cannot be effectively addressed in a timely manner. • Provide a clear grassed path to each outfall for ease of access for maintenance and monitoring of each outfall. • Please have waste product material hauled offsite each week to prevent large stockpiles of waste from accumulating on the grounds, as is the current condition. • Remove accumulated waste metal, plastic and wood materials from the facility and haul to an approved landfill facility. • Provide better general housekeeping for all outside areas of the facility to be proactive in preventing pollutants from this facility from reaching the adjacent Yadkin River. State of North Carolina I Environmental Quality I Energy, Mineral and Land Resources Winston-Salem Regional Office j 450 Hanes Mill Road, Suite 300 1 Winston-Salem, NC 27103 336-776-9800 If you have questions or need additional information, please contact Glen White at (336) 776- 9660. Contact inspector when you feel the SPPP is complete and ready for review. Sincerely, Matthew E. Gantt, P.E. Regional Engineer Land Quality Section Winston-Salem Regional Office Enclosures: Inspection Report cc: NCDEQ - DEMLR (WSRO) NCDEQ — DWR (WSRO) State of North Carolina I Environmental Quality I Energy, Mineral and Land Resources Winston-Salem Regional Office 1 450 Hanes Mill Road, Suite 300 1 Winston-Salem, NC 27103 336-776-9800 Permit: NCG070189 SOC: County: Wilkes Region: Winston-Salem Compliance Inspection Report Effective: 06/01/13 Expiration: 05/31/18 Owner: Plycem USA Inc Effective: Expiration: Facility: Allura 1149 Abtco Rd Contact Person: Jesse Childers Title: Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 02/01/2018 Entry Time: 11:00AM Primary Inspector: Glen White Secondary Inspector(s): North Wilkesboro NC 28659 Phone: 336-696-2007 Certification: Phone: Exit Time: 12:OOPM Phone: 336-776-9800 Sue White Reason for Inspection: Routine Inspection Type: Technical Assistance Permit Inspection Type: Stone, Clay, Glass, and Concrete Products Stormwater Discharge COC Facility Status: Compliant n Not Compliant Question Areas: Storm Water (See attachment summary) Page: 1 Permit; MCGO70189 Owner - Facility: Plycem USA Inc Inspection Date:' 02101/2018 Inspection Type ; Technical Assistance Reason for Visit: Routine Inspection Summary: On February 1, 2018, Glen White and Sue White of NCDEQ - DEMLR visited the Allura facility located at 1149 ABTCO Rd in North Wilkesboro to follow-up on a complaint recieved by the division. Inspectors met with Stephen Phelps (Senior Plant Engineer) and Kim Burton (EHS Manager). The SPPP and records were reviewed and the outfalls and areas of complaint were visited. Determinations and reccomendations made by DEMLR Staff: 1. This facility is covered under the NCG070189 Stormwater Permit. This permit only requires Qualitiative Monitoring be conducted on a semi-annual basis., DEMLR does reserve the right to modify this requirement and man require Allura to begin providing Analytical Monitoring or to obtain a more restrictive Individual Permit if issues cannot be effectively addressed in a timely manner. 2. Provide a clear grassed path to each outfall for access to maintain and monitor the outfalls with ease and safety. 3. Please have waste product materials hauled off site weekly to prevent large stockpiles of waste materials from accumulating as is the current condition. 4. Remove accumulated waste metal, plastic and wood materials from the facility. Haul to an approved landfill facility. 5. Provide better general housekeeping for all outside areas of the facility to be proactive in preventing pollution from this facility from reaching the adjacent Yadkin River. Page: 2 Permit: NCG070189 Owner - Facllity:PlycemUSAInc Inspection Date: 0210112018 Inspection Type : Technical Assistance Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? 0 ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ■ ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? E ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? 0 ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? 0 ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 ❑ ❑ ❑ # Does the facility provide and document Employee Training? 0 ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? 0 ❑ ❑ ❑ # Is the Plan reviewed and updated annually? 0 ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? E ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? E ❑ ❑ ❑ Comment: Qualitative Monitoring Has the facility conducted its Qualitative Monitoring semi-annually? Comment: Yes No NA NE ■❑❑❑ Analytical Monitoring Yes No NA NIE Has the facility conducted its Analytical monitoring? ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? 1111013 Comment: This facility is covered under an NCG070000 industrial Stormwater Permit. The NC070000 permit is for stone, clay, glass and concrete products and only requires analytical monitoring for vehicle maintenance. Under this permit, Allura is not required to provide Analytical Monitoring unless directed by the division for issues related to permit maintenance and stormwater discharges. Permit and Outfall& Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? E ❑ ❑ ❑ # Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ 0 ❑ # Has the facility evaluated all illicit (non stormwater) discharges? E ❑ ❑ ❑ Comment: A path to the outfalls should be maintained so that access for ingress, egress and regress can be easily and safely achieved for maintenance and monitoring. Page: 3 Ft (.C' North Carolina Department of Environment Quality Pat McCrory Governor September 24, 2015 Jesse Childers Plycem USA, Inc. - Allura 1149 Abtco Rd North Wilkesboro, NC 28659 Subject: Compliance Evaluation Inspection NPDES Generai Stormwater Permit NCG000000 Certificate of Coverage NCGO70189 Plycem USA, Inc. - ALLURA Wilkes County Dear Mr, Childers: Donald R. van der Vaart Secretary Glen White of the Winston-Salem Regional Office of the NC Division of Energy, Mineral, and Land Resources (DEMLR) conducted a compliance evaluation inspection at the subject facility on September 16, 2015. Your assistance throughout the process was greatly appreciated. An inspection checklist is attached for your records and the inspection findings are summarized below. 1. Permit This facility holds General Storm water Permit No. NC070189 to discharge Storm water from activities associated with Stone, Clay, Glass and"Concrete Products and like activities under the National Pollutant Discharge Elimination System (NPDES)• The permit became effective June 1, 2013 and expires May 31, 2018. Your permit renewal package must be received in the Central Office in Raleigh no later than 180 days prior to the expiration date of the permit. 2. Records/Reports Part II, Section A of the permit requires the development of a Stormwater Pollution Prevention Plan (SPPP). The plan must include all nine (9) subsections of Part il, Section A of the permit. An updated copy of the SPPP was available for review at the time of inspection. Qualitative monitoring is required to be completed and documented twice yearly as defined in Part II, Section C of the permit. The SPPP plan must be updated annually and qualitative monitoring must be conducted and properly documented semi-annually to retain compliance with the permit. Division of Energy, Mineral, and Land Resources Energy Section • Geological Survey Section • Land Quality Section 1612 Mail Service Center, Raleigh, North Carolina 27699-1612 • 919-707-9200 / FAX: 919-715-8801 512 North Salisbury Street, Raleigh, North Carolina 27604 • Internet: http:Lportal.ncdenr.org/web/Ir/ An Equal Opportunity \ Affirmative Action Employer — 50% Recycled \ 10% Post Consumer Paper 3. Facility Site Review This site manufactures siding used in commercial and residential applications. Much of the product ready for shipping is stored outside behind the building. It is protected from the elements by plastic wrapping material. Site was clean and neat. 4..Effluent/Receiving Waters Stormwater from this site drains into outfalls that empty into the Yadkin River or outfalls that empty directly into the Yadkin River, which is adjacent. 5. Self -Monitoring Program Analytical Monitoring: This site is not required to provide analytical monitoring under current operating procedures. 6. Qualitative Monitoring: All qualitative records do not need to be submitted to DEMLR, however, the records must be kept on file at the facility for a period of five years. Bi-annual monitoring has been done in the past as required per the permit. The latest monitoring was done in March 2015. The next one is just now coming due. 7. Outfails: All outfalls were observed at this time of inspection. A path needs to be cleared to outfall six (6) so that monitoring can be easily and safely accomplished. If you have any questions concerning this letter or the attached inspection report, please contact Glen White at (336) 776-9660. Sincerely, Matthew E. Gantt, P.E. Regional Engineer Land Quality Section Attachments: 1. BIMS Inspection Checklist CC: Division of Land Quality— WSRO Compliance Inspection Report Permit: NCG070189 Effective: 06/01/13 Expiration: 05/31/18 owner: Plycem USA Inc SOC: Effective: Expiration: Facility: Allura County: Wilkes 1149 Abtco Rd Region: Winston-Salem North Wilkesboro NC 28659 Contact Person: ,Jesse Childers Title: Phone: 336-696-2007 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection bate: 09/15/2015 Primary Inspector: Glen White Secondary Inspector(s): Certification: Phone: EntryTime: M00AM Exit Time: 11:00AM Phone: 336-776-9800 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Stone, Clay, Glass, and Concrete Products Stonnwater Discharge COC Facility Status: ® Compliant ❑ Not Compliant Question Areas: ® Storm Water (See attachment summary) Page: 1 Permit: NGG070189 Owner - Facility: Plycem USA Inc Inspection Date: 09/15/2015 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: Met with Jesse Childers at the Allura Facility and reviewed his emvironmental plan and Stormwater Prevention Plan and monitoring records. Records were complete to date but monitoring is now coming due. Walked the site perimeter with Mr. Childers and visited each outfall location. Outfall 6 needs to be cleared of debris, from the fence to the outlet, so it will be easiertmore safe for monitoring to be performed. Page: 2 s l ' Permit: NCG070189 Owner - Facility: Plycem USA Inc Inspection Date: 09115/2015 Inspection Type : Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ®❑ ❑ ❑ # Does the Pian include a General Location (IJSGS) map? ®❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ®❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ® ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ® ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ®❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ®❑ ❑ ❑ # Does the Plan include a I summary? ®❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ®❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ® ❑ ❑ ❑ # Does the facility provide and document Employee Training? ® ❑ ❑ ❑ # Does the Plan include a list of Responsible Parly(s)? ®❑ ❑ ❑ # Is the Plan reviewed and updated annually? ®❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ® ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ®❑ ❑ ❑ Comment: SPPP updated in 2015 Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ ❑ ❑ ❑ Comment: Compliant. „Last monitoring was completed in March 2015. Due for the next monitoring event as soon as the first rain event. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ® ❑ ❑ ❑ # Were all outfalls observed during the inspection? ®❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? 110 ,® ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ®❑ ❑ ❑ Comment: Page: 3 Pat McCrory Governor ATA RCDENR North Carolina Department of Environment and Natural Resources John E. Skvarla, III Secretary May 1, 2014 RECEIVED Mr. Ronnie R. Sheets MAY 0 6 2014 Plycem USA Inc, CENTRAL FILES 1149 ABTco Rd. DWQIBOG North Wilkesboro, NC 28659 Subject: NPDES General Permit NCG070000 Altura Formerly CertainTeed Corporation Certificate of Coverage NCG070189 Wilkes County Dear Mr. Sheets: Division personnel received your request to revise your stormwater permit Certificate of Coverage to accurately reflect your new company and/or facility name. Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency. If you have any questions or need further information, please contact the Stormwater Permitting Program at (919) 807-6300. Sincerely, for Tracy E. Davis, P.E., CPM, Director Division of Energy, Mineral and Land Resources cc: Winston-Salem Regional Office, M. Gantt Stormwater Permitting Program Files Central Niles Division of Energy, Mineral, and Land Resources Energy Section - Geological Survey Section - Land Quality Section 1612 Mail Service Center, Raleigh, North Carolina 27699-1612.919-707-9200 I FAX: 919-715-8801 512 North Salisbury Street, Raleigh, North Carolina 27604 - Internet: httpalportal,ncdenr.org/web/Ir/ An Equal Opportunity 1 Affirmative Action Employer — 50% Recycled 110% Post Consumer Paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG070000 CERTIEtCATE OF COVERAGE No. NCG070189 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, General Shale Brick, Inc. is hereby authorized to discharge stormwater from a facility located at Allura 1149 ABTco Rd North Wilkesboro Wilkes County to receiving waters designated as unnamed tributary to Yadkin River, a class C water in the Yadkin Pee -Dee River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, I1, 1I1, and IV of General Permit No. NCG070000 as attached. This certificate of coverage shall become effective May 1, 2014. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day May 1, 2014 for Tracy E. Davis, P.E., Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission dmllura- 1149 ABTCO Road North Wilkesboro, NC 28659 CERTIFIED MAIL -- RETURN RECEIPT February 1, 2014 North Carolina Division of Water Quality Surface Water Protection Section 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Subject: Ownership Change Notification CertainTeed Corporation North Wilkesboro, North Carolina Certificate of Coverage # NCG070189 We would like to notify the Division of Water Quality — Surface Water Protection Section of an ownership change at the 1149 ABTco Rd. North Wilkesboro, NC 28659 location that operates under Certificate of Coverage # NCG070189. The new ownership change was effective as of 2/1/14. The company ownership is now Plyeem USA Inc. and will operate under the business name Allura at this location. We are submitting the Permit Name and Ownership Change Form to make an ownership change and list the new operators/ dischargers to Allura. The transaction to Allura does not require any changes or modifications to the permit at this time. If future process changes are required, all proper notices and applications will be submitted to the agency for approval. If you have any questions or require any further information, please do not hesitate to contact ,P4 , Jesse Childers, EHS Coordinator directly via telephone at 336-696-2007 x234 or by email at ihilders ,elementia.com Sincerely, Ronald Sheets Plant Manager Allura — Plycem USA Inc. - Division of Water Quality / Surface Water Protection • `���� National Pollutant Discharge Elimination System NC®ENR "RO-" NTROL'N"°E.-Rt"r°` PERMIT NAME/OWNERSHIP CHANGE FORM EnviRpMn[Ni WO NgTuAgL FtE5IX1RCE3 FOR AGENCY USE ONLY Date Received Year Month F Day 1. Plcasc enter the permit number for which the change is requested. NPDES Permit (or) Certificate of Coverage N G S 0 7 1 0 0 1 0 0 N G G 0 1 7 1 0 1 8 9 11. Permit status prior to requested change. a. Permit issued to (company name): CertainTeed Corporation b. Person legally responsible for permit: Ronnie R Sheets First M I Last Plant Manager 'title 1149 A BTco Rd. Permit I ]older Mailing Address North Wilkesboro NC 28659 City State Zip 336) 696-2007 (336) 696-2243 I'lione Fax c. Facility name (discharge): CertainTeed Cot• oration d. Facility address: 1149 Al3Tco Rd. Address North Wilkesboro NC 28659 City State Zip c. Facility contact person: Jesse A Childers (336) 696-2007 First / M1 1 Last Phonc [I[. Please provide the following for the requested change (revised permit). a. Request for change is a result of: ® Change in ownership of the facility ® Natne change of the facia ity or owner If other please explain: b. Permit issued to (company name): Plycem USA Inc. _ c. Person legally responsible for permit: Ronnie R Sheets J _ First M1 Last 17��5 �iil j� Plant Manager d°J L5 j� 'Title u 1149 A131'co Rd. F ES rt 8 20I Permit Holder Mailing Address North Wilkesboro NC 28659 U NR - WATE UALITY City State Zip W ti&nds 8 �cT�nwtradsr t3ranch (336) 696-2007 rsheets a,)clenientia.coin Phone E-mail Address d. Facility name (discharge): Allura e. Facility address: 1149 ABTco Rd. Address North Wilkesboro NC 28659 City stoic Zip f. Facility contact person: Jesse A Childers First MI Last (336) 696-2007 jchilders a cletnentia.com Phone E—mail Address Revised 2C12Apr23 NPDES PERMIT NAME/OWNERSHIP CHANGE FORM Page 2 of 2 IV. Permit contact information (if different from the person legally responsible for the permit) Permit contact: Jesse A Childers First Ml Last El -IS Coordinator Title 1 149 ABTco Rd. Mailing Address North Wilkesboro NC 28659 City State Zip (336) 696-2007 ihilders a eteinentia.coin Phone E-mail Address V. Will the permitted facility continue to conduct the same industrial activities conducted prior to this ownership or name change? ® Yes ❑ No (please explain) VI Required Items: THIS APPLICATION WILL BE RETURNED UNPROCESSED IF ITEMS ARE INCOMPLETE OR MISSING: ® This completed application is required for both name change and/or ownership change requests. ® Legal documentation of the transfer of ownership (such as relevant pages of a contract deed, or a bill of sale) is required for an ownership change request. Articles of incorporation are not sufficient for an ownership change. The certifications below must be completed and signed by both the permit holder prior to the change, and the new applicant in the case of an ownership change request. For a name change request, the signed Applicant's Certification is sufficient. PERMITTEE CERTIFICATION (Permit holder prior to ownership change): 1 , attest that this application for a name/ownership change has been reviewed and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information is not included, this application package will be returned as incomplete. Signature Date APPLICANT CERTIFICATION I, , attest that this application for a name/ownct-ship change has been reviewed and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information is not included, this application package will be returned as incom fete. Signature Date PLEASE SEND THE COMPLETE APPLICATION PACKAGE TO: Division of Water Quality Surface Water Protection Section 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Revised 712008 1 � EXECt1TION COPY ASSIGNMENT AND ASSUMPTION, BILL OF SALE AND CONVEYANCE THIS ASSIGNMENT AND ASSUMPTION, BILL OF SALE AND CONVEYANCE (this "Assignment") is made and entered into as of February 1, 2014 by and between CertainTeed Corporation, a Delaware corporation (the "Seller"), and Plycem USA, Inc., a Georgia corporation (the "Buyer"). BACKGROUND A. The Buyer and the Seller are parties to that certain Purchase Agreement, dated December 18, 2013 (the "Purchase Agreement"), pursuant to which the Seller has agreed to: (i) sell, convey, grant, assign, transfer and deliver to the Buyer, and the Buyer has agreed to purchase and acquire and accept from the Seller, the Conveyed Assets free and clear of all Liens; and (ii) assume the Assumed Liabilities. B. Initially capitalized terms not defined in this Assignment shall have the meanings ascribed to such terms in the Purchase Agreement. TERMS NOW, 'THEREFORE, in consideration of the foregoing premises and of the mutual covenants hereinafter set forth, and for other good and valuable consideration, the receipt and sufficiency of which are hereby acknowledged, the parties hereto, intending to be legally bound, hereby agree as follows: ARTICLE I TRANSFER OF CONVEYED ASSETS AND ASSUMPTION OF ASSUMED LIABILITIES 1.1. Transfer of Conveyed Assets, The Seller hereby sells, conveys, grants, assigns, transfers and delivers unto the Buyer all of the Conveyed Assets free and clear of all Liens. The Buyer hereby accepts such sale, conveyance, grant, assignment, transfer and delivery. 1.2. Assumption of Assumed Liabilities. The Buyer hereby assumes, and shall discharge and pay when due, the Assumed Liabilities, in each case in accordance with the terms and conditions in the Purchase Agreement. ARTICLE 11 MISCELLANEOUS 2.1. No Waiver or Modification; Sub'ect to Purchase A reement. Nothing contained in this Assignment may be construed as a waiver of any rights or remedies of the parties hereto as set foth in, or arising in connection with, the Purchase Agreement or any other instrument or document delivered by the parties hereto pursuant to the Purchase Agreement. This Assignment is not intended to limit in any manner the terms of the Purchase Agreement nor is it intended to create any obligation broader than those specifically set forth in the Purchase Agreement. in the event of a conflict or inconsistency between this Assignment and the Purchase Agreement, the terms of the Purchase Agreement shall prevail. Neither this Assignment nor any I {( )l1: 3280519.5 term hereof may be changed, waived, discharged, or terminated other than by an instrument in writing signed by the parties hereto. No failure to enforce any provision of this Assignment shall be deemed to or shall constitute a waiver of any other provision hereof nor shall such waiver constitute a continuing waiver. This Assignment is subject to all of the representations, warranties, covenants, exclusions and indemnities set forth in the Purchase Agreement. 2.2. Binding Effect; Successors and Assigns. This Assignment shall be binding upon and inure to the benefit of the parties hereto and their respective successors and assigns. 2.3. Counterparts; Effectiveness. This Assignment may be executed in two counterparts, each of which shall be deemed to be an original but both of which shall constitute one and the same agreement. This Assignment shall become effective when each party hereto shall have received counterparts thereof signed and delivered (by telecopy or other electronic means) by the other party hereto. 2.4. Governing Law. THIS ASSIGNMENT AND THE LEGAL RELATIONS BETWEEN THE PARTIES HERETO SHALL BE GOVERNED BY AND CONSTRUED IN ACCORDANCE WITH THE LAWS OF THE STATE OF NEW YORK, WITHOUT REGARD '1'O THE CONFLICT OF LAWS RULES THEREOF (OTHER THAN SECTIONS 5-1401 AND 5-1402 OF THE NEW YORK GENERAL OBLIGATIONS LAW). [REMAINDER Of PAGE INTENTIONALLY LEFT BLANK, SIGNATURE PAGE FOLLOWS] -2- IN WITNESS WHEREOF, the parties have caused this Assignment and Assumption, Bill of Sale and Conveyance to be duly executed as of the date first written above. SELLER: CERTAINTEED CORPORATION BY• Name: Robert J. Panaro Title: Vice President and Chief Financial Officer BUYER: PLYCEM USA, INC. BY: .._. Name: Title: IN WITNESS WHEREOF, the parties have caused this Assignment and Assumption, Bill of Sale and Conveyance to be duly executed as of the date first written above. SELLER: CERTAINTEED CORPORATION By: _ Name Title: : Tki Robert J. Paaaro Vice President and Chief Financial Officer PLYCEM USA, INC. By: - C� Name; 3�`Ca L t AVaSCUCS Title: C;=-o STATE OF COUNTY OF 011 e.5 1-e/' Robert J. Panaro, being duly sworn, says that he is the Vice President and Chief Financial Officer of CERTAINTEED CORPORATION, a Delaware corporation, and acknowledges that he did sign the Assignment and Assumption, Bill of Sale and Conveyance on behalf of CERTAINTEED CORPORATION, pursuant to due authority. CERTAINTEED CORPORATION Name: Robert J. Panaro Title: Vice President and Chief Financial Officer Sworn to and subscjbed before me this &^ flay of Jan Iary, 2014. ,Notary Public My commission expires: L `? "2-'17 (SEAL) -')IA (jNW£ALTHOFPENNSYLVANIA NOTARIAL SEAL SUSAN M. GIUSTI, Notary Public 1 Tredyffrin TiNp., ChesWr County MX Commission Expires August 29, 2017 couvrY oi- �f -'�-,:' (. i 1f 1,,,ti ein+g duly sworn. says that he is the � C of PLYCEM USA, INC.. a Georgia corporation, and acknowledges that [she/he] did sign the Assignment and ;Assumption. Bill of Sale and Conveyance on Behalf of PLYCI;AI USA. INC.. pursnam to due authority. PLYCEM USA, IN f3v: Name: ��5' L h�G�WCfaC� C.S Title: GEC Sworn to and subscribed before me this _ day N. ABPAHAM GONZALF1 of, ;r „ ',: f �+ NOTARY PUBLIC STATE OF / �oF1 TOMMY COMM EXP 04.09.2016 Notary Public My commission expires: Q'` ' Jc. , lot 6 (SEAL) NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Mr. Ronnie R. Sheets Plycem USA Inc, 1149 ABTco Rd. North Wilkesboro, NC 28659 Dear Mr. Sheets: May 1, 2014 John E. Skvarla, M Secretary RECEIVED MAY 2 0 2014 CENTRAL fi1LES DWQIBOG Subject: NPDES General Permit NCG070000 Allura Formerly CertainTeed Corporation Certificate of Coverage NCG070189 Wilkes County Division personnel received your request to revise your stormwater permit Certificate of Coverage to accurately reflect your new company and/or facility name. Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency. If you have any questions or need further information, please contact the Stormwater Permitting Program at (919) 807-6300. Sincerely, ORIGINAL. SIGNED 131 E. N PICKLE for Tracy E. Davis, P.E., CPM, Director Division of Energy, Mineral and Land Resources cc: Winston-Salem Regional Office, M. Gantt Stormwater Permitting Program Files Central Files Division of Energy. Mineral, and Land Resources Energy Section - Geological Survey Section - Land Quality Section 1612 Mail Service Center, Raleigh, North Carolina 27699-1612.919.707-92001 FAX: 919-715-8801 512 North Salisbury Street, Raleigh, North Carolina 27604 - Internet: http://Dortal,ncdenr.org/web/Ir/ An Equal Opportunity 1 Affirmative Action Employer — 50% Recycled 110% Post Consumer Paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG070000 CERTIFICATE OF COVERAGE No. NCG070189 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Plycem USA, Inc is hereby authorized to discharge stormwater from a facility located at Allura 1149 ABTco Rd North Wilkesboro Wilkes County to receiving waters designated as unnamed tributary to Yadkin River, a class C water in the Yadkin Pee -Dee River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, lI, III, and IV of General Permit No. NCG070000 as attached. This certificate of coverage shall become effective May 1, 2014. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day May 1, 2014 for Tracy E. Davis, P.E., Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission NC®ENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Mr. Ronnie R. Sheets Plycem USA Inc, 1149 ABTco Rd. North Wilkesboro, NC 28659 Dear Mr. Sheets: John E. Skvarla, ill Secretary May 1, 2014 y. " RECEIVED N.C. Dept. of ENR :., MAY 0 6 2014 �r 4 VViNSTON-SALEM REGIONAL OFFICE Subject: NPDES General Permit NCG070000 Allura Formerly CertainTeed Corporation Certificate of Coverage NCG070189 Wilkes County Division personnel received your request to revise your stormwater permit Certificate of Coverage to accurately reflect your new company and/or facility name. Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency. If you have any questions or need further information, please contact the Stormwater Permitting Program at (919) 807-6300. Sincerely, ORIGINAL SIGNED 8� KEN PICKLE for Tracy E. Davis, P.E., CPM, Director Division of Energy, Mineral and Land Resources cc: Winston-Salem Regional Office, M. Gantt Stormwater Permitting Program Files Central Files Division of Energy, Mineral, and Land Resources Energy Section • Geological Survey Section • Land Quality Section 1612 Mail Service Center, Raleigh, North Carolina 27699-1612.919-707-92001 FAX: 919-715-8801 512 North Salisbury Street, Raleigh, North Carolina 27604 • Internet: http:Ilportal.ncdenr.orolwebllrl An Equal Opportunity 1 Affirmative Action Employer — 50% Recycled 110% Post Consumer Paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG070000 CERTIFICATE OF COVERAGE No. NCG070189 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, General Shale Brick, Inc. is hereby authorized to discharge stormwater from a facility located at Ahura 1 149 ABTco Rd North Wilkesboro Wilkes County to receiving waters designated as unnamed tributary to Yadkin River, a class C water in the Yadkin Pee -Dee River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 1I, III, and IV of General Permit No. NCG070000 as attached. This certificate of coverage shall become effective May 1, 2014. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day May 1, 2014 ORIGINAL SIGNED M KEN PICKLE for Tracy E. Davis, P.E., Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission �sciaao�ana NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Mr. Ronnie R. Sheets Plycem USA Inc, 1149 ABTco Rd. North Wilkesboro, NC 28659 Dear Mr. Sheets: John E. Skvarla, III r" RECEfVED Secretary i N.C. Dept of ENR n May 1, 2014 MAY 2 3 2014 WINSiON-SALEM REGIONALOFFICE Subject: NPDES General Permit NCG070000 Allura Formerly CertainTeed Corporation Certificate of Coverage NCG070189 Wilkes County Division personnel received your request to revise your stormwater permit Certificate of Coverage to accurately reflect your new company and/or facility name. Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency. If you have any questions or need further information, please contact the Stormwater Permitting Program at (919) 807-6300. cc: zWinston-Salem Regional Office, M. Gantt Stormwater Permitting Program Files Central Files Sincerely, ORIGINAL SIGNED S� 9 N FICKLE for Tracy E. Davis, P.E., CPM, Director Division of Energy, Mineral and Land Resources 0DrrfC+tJ Coc i e,Wr -'ie—f Division of Energy, Mineral, and Land Resources Energy Section - Geological Survey Section - Land Quality Section 1612 Mail Service Center, Raleigh, North Carolina 27699-1612.919-707-92001 FAX: 919-715-8801 512 North Salisbury Street, Raleigh, North Carolina 27604 • Internet: httpJ/portal.ncdenrrorg/wehllrl An Equal Opportunity 1 Affirmative Action Employer — 50% Recycled 110% Post Consumer Paper f+ i STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG070000 CERTIFICATE OF COVERAGE No. NCG070189 STORM WATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Plycem USA, Inc is hereby authorized to discharge stormwater from a facility located at Allura 1149 ABTco Rd North Wilkesboro .Wilkes County to receiving waters designated as unnamed tributary to Yadkin River, a class C water in the Yadkin Pee -Dee River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, I1, I1I, and IV of General Permit No. NCG070000 as attached. This certificate of coverage shall become effective May 1, 2014. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day May 1, 2014 for Tracy E. Davis, P.E., Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Mr. Ronnie R. Sheets Plycem USA Inc, 1149 ABTco Rd. North Wilkesboro, NC 28659 Dear Mr. Sheets: John E. Skvarla, III Secretary May 1, 2014 Subject: NPDES General Permit NCG070000 Allura Formerly CertainTeed Corporation Certificate of Coverage NCG070189 Wilkes County Division personnel received your request to revise your stormwater permit Certificate of Coverage to accurately reflect your new company and/or facility name. Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency. If you have any questions or need further information, please contact the Stormwater Permitting Program at (919) 807-6300. Sincerely, ORIGINAL SIGNED IP KEN PICKLE far Tracy E. Davis, P.E., CPM, Director Division of Energy, Mineral and Land Resources cc-, Winston-Salem Regional Office, M. Gantt Stormwater Permitting Program Files Central Files Division of Energy, Mineral, and Land Resources Energy Section • Geological Survey Section - Land Quality Section 1612 Mail Service Center, Raleigh, North Carolina 27699-1612.919-707-92001 FAX: 919-715-8801 512 North Salisbury Street, Raleigh, North Carolina 27604 • Internet: htip:ltportal.ncdenr.org/web/ir/ An Equal Opportunity l Affirmative Action Employer — 50% Recycled 110% Post Consumer Paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG070000 CERTIFICATE OF COVERAGE No. NCG070189 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other Iawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Plycem USA, Inc is hereby authorized to discharge stormwater from a facility located at Allura 1149 ABTco Rd North Wilkesboro Wilkes County to receiving waters designated as unnamed tributary to Yadkin River, a class C water in the Yadkin Pee -Dee River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, and IV of General Permit No. NCG070000 as attached. This certificate of coverage shall become effective May 1, 2014. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day May 1, 2014 for Tracy E. Davis, P.E., Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission CertainTeed 1149 ABTCO Road North Wilkesboro, NC 28659 CERTIFIED MAIL, RETURN RECEIPT REQUESTED Division of Water Quality Surface Water Protection 1617 Mail Service Center Raleigh, North Carolina 27699-1617 October 29, 2013 Re: Authorized Person change for CertainTeed - Roaring River Storm Water Discharge - Certificate # NCG070189 E 1 [1@[90 NOV -52013 I am submitting a request for the authorized person/contact for CertainTeed Roaring River under Certificate # NCG070189 to be changed from Allan R. Schreiner, Plant Manager to Ronald Sheets, Interim Plant Manager. Thank you for your assistance in this matter. If you have any questions regarding this request, please contact Jesse Childers at 336-696-2007 Fact 234. Sincerely, Ronald Sheets — Interim Plant Manger 1149 ABTco Rd North Wilkesboro, NC 28659 336-696-2007 ext 260 ronald.sheets@saint-gobain.com N Division of Water Quality / Surface Water Protection ZnI AS ;je National Pollutant Discharge Elimination System NCDENR PERMIT NAME/OWNERSHIP CHANGE FORM F.I.V"p�,tE""+"� VAIGliµ. Fi�JiiCl9 FOR AGENCY USE ONLY Date Received Year Month Da I. Please enter the permit number for which the change is requested. NPDES Permit (or) Certificate of Coverage N G� 0 3V G G �] Q 1 11. Permit status prior to requested change. \ a. Permit issued to (company name): b. Person legally responsible for permit: First MI Last Facility name (discharge): d. Facility address: Title Permit Holder Mailing Address City State Phone Fax Address Zip City State Zip e. Facility contact person: ( ) First / MI/Last Phone III. Please provide the following for the requested change (revised permit). a. Request for change is a result of: ❑ Change in ownership of the facility Name change of the facility or owner If other please explain: Cr",��L � ��,�} Y��� b. Permit issued to (company name): c. Person legally responsible for permit: P-,0Y1aV) R Sj&,z� First MI Last Title Permit Holder Mailing Address � r 4: ;164J2,- co 17C, City State Zip s �33 � t't na L c� sa d ,,� .0 o �. n Phone E-mail Address d. Facility name (discharge): e. Facility address: Address City State Zip f. Facility contact person: R C?k.,Vb First MI Last ( 334 ) 16i1. 2b�i ,ess- . CA ,i ce 5c=tiln�- ir.r Phone E-mail Address Revised 2012Apr23 NPDES PERMIT NAME/OWNERSHIP CHANGE FORM Page 2 of 2 IV. Permit contact information (if different from the person legally responsible for the permit) Permit contact: `}use.. 4 CAE 2-'(� First Mt Last Title 1l �9 ,Z7C Mailing Address ` o'-o- odk a 19 c -45- City - State Zip Phone E-mail Address V. Will the permitted facility continue to conduct the same industrial activities conducted prior to this ownership or name change? E� Yes ❑ No (please explain) VI. Required Items: THIS APPLICATION WILL, BE RETURNED UNPROCESSED IF ITEMS ARE INCOMPLETE OR MISSING: ❑ This completed application is required for both name change and/or ownership change requests. ❑ Legal documentation of the transfer of ownership (such as relevant pages of a contract deed, or a bill of sale) is required for an ownership change request. Articles of incorporation are not sufficient for an ownership change. The certifications below must be completed and signed by both the permit holder prior to the change, and the new applicant in the case of an ownership change request. For a name change request, the signed Applicant's Certification is sufficient. PERMITTEE CERTIFICATION (Permit holder prior to ownership change): I, , attest that this application for a name/ownership change has been reviewed and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and tliat if all required supporting information is not included, this application package will be returned as incomplete. Signature Date APPLICANT CERTIFICATION 1, , attest that this application for a name/ownership change has been reviewed and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information is not included, this application package will be returned incomplete. `ll Signature Date PLEASE SEND THE COMPLETE APPLICATION PACKAGE TO: Division of Water Quality Surface Water Protection Section 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Revised 712009 '1 �r NCDENR r,,--HF11T A`-n IIAILIRAI, RFS-,",. Division of Water Quality 1 Surface Water Protection National I'ollutant Discharge l limination System PERMIT NAMEIOWNERSHIP CHANGE FORM FOR AGENCY USE ONLY Date Received Year Month Day I. Please enter the permit number fbr which fhc change is requested. NPDI?S Permit (or) Certificate of' Cove ragc N I C 18 1 Q N I G 10 10 7 tl 1 I 1 8 9 [l. Permit status t� rinr tlr requested change. a. Pc:rnlit issued to (company name): CcrtainTecd Cor�oralion h. Person legally responsible for pel•nlit: Daniel J Hurley First ml I,asl Tit Ie 1 149 ABTC0 Road Pcrmit I lolder Mailing Address North Wilkesboro NC 28659 City State Zip (336) 696-2007 (336) 696-2243 phone FaxC. facility name (discharge): CcrtainTced Corporation d. Facility address: 11.49 ABTCO Road Address North Wilkesboro NC 28659 City State Zip e. facility contact person: Daniel J Hin-ley (336) 696-2007 1~ first 1 M [ 1 Last Phone 111. ['lease provide the following for the requested change (revised permit). a. Request for changc is a result of: ❑Change in ownership ohthc facility ❑ Name change ofthc facility or owner If olher p1cf/ce expluirr: Change to facility contact person (previously Daniel Hurley) b. 1'C1.1111l Issucd IO (Coillpally llillllc): Cutaln I eed C0r1H)ration C. Pcl-still legally 1'Cspollslble fol' pel'Illlt: Gina A MCI)o\ycll % First MI Last ►` Hulilall Resottrces & Sal ,Cty Manager Title 1 149 AB TC0 Road permit I !older Mailing Address North Wilkesboro NC 28659 City State Zip 336 696-2007 Gitia.A.MCDowell rr saint-�obain.com Phone 1:-mail Address d. Facility mulle (discharge): Cct-milffhced C01-pol-mion C. Facifity addl-css: 1 149 A13TC0 Road Address North Wilkesboro NC 28659 City State Zip f: Facililvcontact person: Gina A McDowell First MI bast (336) 696-2007� Gina.A.McDowell a saint-gobain.com Phone E-mail Address Revised 2012Ap23 :.* c l NPDES PERMIT NAMEIOWNERSHIP CHANGE FORM Page 2 of 2 IV. Permit contact information (if different front the person legally responsible for the permit) Permit contact: First IN l Last Title Failing Address Cite State "Lip ( Phone E—mail Address V. Will the permitted facility continue to conduct the same industrial activities conducted prior to this ownership or name change? ® Yes ❑ No (please explain) VI. Ilcquired Items: 1411S APPLICATION WILL, RE RETURNED UNPROCESSED IF ITEMS ARE INCOMPL EITI. OR MISSING: ❑ This corltpleted application is required for both name change and/or ownership change rcqucsts. ❑ I.,egal docunrentatloll ol'Ihe transfer ofownership (such as relevant pages ol'a contract deed, or a bill ol, sale) is res�ired liar- an ownership change reducsl. Ai-ticics ot' incorporation .,we not snl f icicrlt for an ownel'sltip change. The certifications helow nrrlst he completed and signed by both the permit holder prior to the change. and the new applicant in the C,Ise ofall ownership change regllesl. I -or a flame change request. llte si`"'llcd Applicants Certification is sufficicnl. PERMIT E,E CERTIFICATION (Permit holder prior' to ownership change): 1. .attest that this appli ation liar a narlte/ownership change has. been reviewed and is aCCuratc and coniplele to the best of nw knowledgc. i understand that if all rcgnircd parrs of'this application arc not C0111plClcd rind that if all required supporting infornralion is not included, this application package will he rcttrrnCd as incomplete. Signature Date APPLiCANT CERTIFICATION 1, Gina A McDowell, attest that this application for a name/owner'ship change has hecn reviewed and is accurate and colliplete to the best of m_y knowledge. i understand that Wall required parts of-illis application arc not completed and that ifall required supporting infiirnrttion is not included. this application package will hC returned as inComplCle. __&Y-1Gt, G� 3 / 1 1 / 13 Slglliattre Date PLEASE+, SEND TLIE COMPLETE APPLICATION PACKAGE TO: Division of Watcr Quality SurFtcc Water Protection Section 1617 Mail Service Center Raleigh, Not -Ili Carolina 27699-I617 Revised 712008 NODE R North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary October 7, 2010 Mr. Dan Hurley Certain Teed Corporation 1149 ABTco Road North Wilkesboro, NC 28659 Subject: Compliance Evaluation Inspection - Stormwater Permit 4 NCG070189 Wilkes County Dear Mr. Hurley: On October 4, 2010 a Compliance Evaluation Inspection was performed by George " h, ofithILM e. Mr. Dan Hurley, Mr. Neil Gresham, and Ms. Gina McDowell were present for the inspection " Permit z'' ; Previously, Certain Teed was covered under the NCG210000 which applies to indu engagddi imber Products, which does not fit the industrial classification for this permit. On August 27, 2010 the certificate of coverage for NPDES General Permit NGG070000 was issued, which is primarily for industries engaged in: Stone, Clay, Glass, and Concrete Products. Qualitative Monitoring is required per Part II, Section B. Please insure the monitoring for this requirement is performed as required in the pen -nit. In a letter from the Division dated August 27, 2010, analytical monitoring is required for COD, TSS, and pH. This is further discussed in the section, Self -Monitoring Program, of this report. Records & Reports All records and reports are kept on file as required in the permit. Facility Site Review The site inspection showed a chemical loading area from rail trains. The storm grate is sealed when off loading is performed. There is concrete fiber siding stored on the impervious areas of the facility. The product is sealed in a Certain Teed logo shrink wrap plastic. North Carolina Division of Water Quality, Winston-Salem Regional Office Location: 585 Waughtown St. Winston-Salem, North Carolina 27107 Phone: 336-771.50001 FAX: 336-771-46301 Customer Service: 1-877-623-6748 tntemet: www.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer NorthCarolina Natumllry CEI October 7, 2010 Page 2 of 2 There is off specification and damaged product that is temporarily stored on pervious surface that has no point source discharge. The area is well bermed. Self -Monitoring Program As discussed the following Outfalls will apply: Outfall #001 - Certain Teed stormwater draining from the storage yard to a vegetative ditch and discharging to the Yadkin River. Out fall #002 - Certain Teed stormwater draining from an adjacent storage area and discharging to the Yadkin River. Outfall #006A — Certain Teed stormwater from the roof drains to a black rib Culvert in the manhole. The bottom of the manhole receives water from LP. Outfall #006B - Certain Teed stormwater from the front unloading area of the building to a concrete Culvert in the manhole. The bottom of the manhole receives water from LP. Please prepare a schematic showing the Outfall sampling points and a description of how the sample is ZD collected. Please submit this at the sample you complete the required sampling. During our meeting it was discussed that Certain Teed will collect analytical samples for COD, TSS, and pH from each of the above outfalls. There will be a monthly sample collected, for each parameter described above, during each month from October through December 2010. (three (3) sample sets from each outfall) During January 2011 the analytical samples will be submitted to this office to compare the COD, TSS, and pH against the benchmark values in the NCG210000 permit. if the analytical results demonstrate that the outfalls will not exceed benchmark values the analytical monitoring, as described in the August 27, 2010 letter, will no longer be required. The compliance evaluation inspection is satisfactory. Mr. Hurley is going a very good job implementing the stormwater monitoring requirements as described in the permit, if you have any questions please contact George Smith or me at (336) 771-5000. Sincerely, Steve W. Tedder Regional Supervisor cc: Stomiwater,1?erntitting.Unit•—.t3rian,Lo,�vther WSRO Files i Compliance Inspection Report Permit: NCG070189 Effective: C8127110 Expiration: 05/31/13 Owner: Certain Teed Corportation SOC: Effective: Expiration: Facility: Certain Teed Corporation County: Wilkes 1149 Abtco Rd Region: Winston-Salem North Wilkesboro NC 28659 Contact Person: Daniel J Hurley Title: Phone: 336-696-2007 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Certification: Phone: Inspection Date: 10/04/2010 Entry Time: 10:00 AM Exit Time: 11:15 AM Primary Inspector: George S Smith Phone: 336-771-5000 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Stone, Clay, Glass, and Concrete Products Stormwater Discharge CQC Facility Status: ® Compiiant ❑ Not Compliant Question Areas: ® Storm Water (See attachment summary) Page: 1 Permit: NCG070189 Owner - Facility: Certain Teed Corporiation Inspection Date: 10/0412010 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Page: 2 rJ Permit: NCG070189 Owner - Facility: Certain Teed Corportation Inspection Date: 10/0412010 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ® n n n # Does the Plan include a General Location (USGS) map? ® n n n # Does the Plan include a "Narrative Description of Practices"? ® n n n # Does the Plan include a detailed site map including outfall locations and drainage areas? ® n n n # Does the Plan include a list of significant spills occurring during the past 3 years? ® n n n # Has the facility evaluated feasible alternatives to current practices? ® n n n # Does the facility provide all necessary secondary containment? ® n n n If Does the Plan include a BMP summary? Cm n n n # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ® n n n # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ® n n n # Does the facility provide and document Employee Training? ® n n n # Does the Plan include a list of Responsible Party(s)? ®n n n # Is the Plan reviewed and updated annually? ®n n n # Does the Plan include a Stormwater Facility Inspection Program? ® n ❑ n Has the Stormwater Pollution Prevention Plan been implemented? ® n n n Comment: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ® n n n Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ® n n n # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? n n ® n Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ® n n n # Were all outfalls observed during the inspection? ® n n n # If the facility has representative outfall status, is it properly documented by the Division? ❑ n ®n # Has the facility evaluated all illicit (non stormwater) discharges? n n ® n Comment: Page: 3 r NC®ENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director October 7, 2010 Mr. Dan Hurley Certain Teed Corporation 1149 ABTco Road North Wilkesboro, NC 28659 Subject: Compliance Evaluation Inspection - Stormwater Permit # NCG070189 Wilkes County Dear Mr. Hurley: Dee Freeman Secretary On October 4, 2010 a Compliance Evaluation Inspection was performed by George Smith, of this office. Mr. Dan Hurley, Mr. Neil Gresham, and Ms. Gina McDowell were present for the inspection. Permit Previously, Certain Teed was covered under the NCG210000 which applies to industries engaged in Timber Products, which does not fit the industrial classification for this permit. On August 27, 2010 the certificate of coverage for NPDES General Permit NGG070000 was issued, which is primarily for industries engaged in: Stone, Clay, Glass, and Concrete Products. Qualitative Monitoring is required per Part I1, Section B. Please insure the monitoring for this requirement is performed as required in the permit. In a letter from the Division dated August 27, 2010, analytical monitoring is required for COD, TSS, and pH. This is further discussed in the section, Self -Monitoring Program, of this report. Records & Reports All records and reports are kept on file as required in the permit. Facility Site Review The site inspection showed a chemical loading area from rail trains. The storm grate is sealed when off loading is performed. There is concrete .fiber siding stored on the impervious areas of the facility. The product is sealed in a Certain Teed logo shrink wrap plastic. North Carolina Division of Water Quality, Winston-Salem Regional Office Location: 585 Waughtown St Winston-Salem, North Carolina 27107 One Phone: 336-771-54001 FAX: 336-771-46301 Customer Service: 1-877-623-6748 North Carolina Internet: www.ncwaterquality.org Naturally An Equat Opportunity 1 Affirmative Action Employer �/ y " w CE1 October 7, 2010 Page 2 of 2 There is off specification and damaged product that is temporarily stored on pervious surface that has no point source discharge. The area is well bermed. Self-tonitoring Program As discussed the following Outfalls will apply: Outfall 4001 - Certain Teed stormwater draining from the storage yard to a vegetative ditch and discharging to the Yadkin River. Outfal1 4002 - Certain 'feed stormwater draining from an adj acent storage area and discharging to the Yadkin River. Outfall 9006A — Certain Teed stormwater from the roof drains to a black rib Culvert in the manhole. The bottom of the manhole receives water from LP. OutfalI 9006B - Certain Teed stormwater from the front unloading area of the building to a concrete Culvert in the manhole. The bottom of the manhole receives water from LP. Please prepare a schematic showing the outfall sampling points and a description of how the sample is collected. Please submit this at the sample you complete the required sampling. During our meeting it was discussed that Certain Teed will collect analytical samples for COD, TSS, and pl-1 from each of the above outfalls. There will be a monthly sample collected, for each parameter described above, during each month from October through December 2010. (three (3) sample sets from each outfall) During January 2011 the analytical samples will be submitted to this office to compare the COD, TSS, and pH against the benchmark values in the NCG210000 permit. if the analytical results demonstrate that the outfalls will not exceed benchmark values the analytical monitoring, as described in the August 27, 2010 letter, will no longer be required. The compliance evaluation inspection is satisfactory. Mr. Hurley is going a very good job implementing the stormwater monitoring requirements as described in the permit. If you have any questions please contact George Smith or me at (336) 771-5000. Sincerely, Steve W. Tedder Regional Supervisor cc: Stormwater Permitting Unit— Brian Lowther ,WS�les e Compliance inspection Report Permit: NCG070189 Effective: 08/27/10 Expiration: 05/31/13 Owner: Certain Teed Corportation SOC: Effective: Expiration: Facility: Certain Teed Corporation County: Wilkes 1149 Abtco Rd Region: Wnston-Salem North Wilkesboro NC 26659 Contact Person: Daniel J Hurley Title: Phone: 336-696-2007 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 1010412010 Primary Inspector: George S Smith Secondary Inspector(s): Certification Entry Time: 10 00 AM Exit Time: 11.15 AM Phone: Phone: 336-771-5000 . Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Stone, Clay, Glass, and Concrete Products Stormwater Discharge COC Facility Status: ® Compliant ❑ Not Compliant Question Areas: ® Storm Water (See attachment summary) Page: 1 Permit: NCG070189 Owner - Facility: Certain Teed Corportation Inspection Date: 10/04/2010 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Page:2 Permit: NCG070169 Owner - Facility: Certain Teed Corportation Inspection Date: 10/04/2010 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ® n n n # Does the Plan include a General Location (USGS) map? ® n n n # Does the Plan include a "Narrative Description of Practices"? ® n n n # Does the Plan include a detailed site map including outfall locations and drainage areas? ® n n n # Does the Plan include a list of significant spills occurring during the past 3 years? ® n n n # Has the facility evaluated feasible alternatives to current practices? ® n n n # Does the facifity provide all necessary secondary containment? ® n n n # Does the Plan include a BMP summary? ® n n n # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ® n n n # Does the Pian include a Preventative Maintenance and Good Housekeeping Plan? ® n n n # Does the facility provide and document Employee Training? ® n n n # Does the Plan include a list of Responsible Party(s)? ® n n n # is the Plan reviewed and updated annually? ® n n n # Does the Plan include a Stormwater Facility Inspection Program? ® n n n Has the Stormwater Pollution Prevention Plan been implemented? ® o n n Comment: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ® n n n Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ® n n n # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? n M ® ❑ Comment: Permit and Qutfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ® n ❑ n # Were all outfalls observed during the inspection? ® n n In # If the facility has representative outfall status, is it properly documented by the Division? n n ® o # Has the facility evaluated all illicit (non stormwater) discharges? n n ® n Comment: Page: 3 ��A illy� ALIRECEIVED NCDENR N.C, Oeat. of ENR I North Carolina Department of Environment and Natural Resources AUG 3 0 2010 I Division of Water Quality Winston-Salem Beverly Eaves Perdue Coleen H. Sullins Dee'Eff an Governor Director Secretary August 27, 2010 Mr. Daniel J. Hurley CertainTeed Corporation 1149 ABTCO Rd North Wilkesboro, NC 28659 Subject: General Permit No. NCG070000 CertainTeed Corporation COC NCG070189 Wilkes County Dear Mr. Hurley: In accordance with your application for a discharge permit received on June 25, 2010, we are forwarding herewith the subject certificate of coverage to discharge under the subject state — NPDES general permit. This pen it is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between Nofih Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Additional monitoring for this site is required because the anal yt ,_al.monitoring taken for the site's current permit (NCG210340) has values over the current benchmarks. This facility should be covered under the NCG07 (Stone, Clay, & Glass) but has'beeti covered under an NCG21 (Timber). Therefore, samples must be taken to determine if the parameters over the benchmarks are coming from stormwater associated with the CertainTeed Facility. The following analytical monitoring should be performed until the Winston Salem Regional -Office has adequate data to show parameter benchmark exceedances are not because of stormwater coming from CcrtainTeed's facility. If the samples indicate that parameters are over the benchmarks because of stormwater coming from the CertainTeed site then an individual permit may be required at that time. Required analytical monitoring: Analytical monitoring shall continue ac6..ding to the NCG21 permit forXOD,_TSS;.an&pH.f Pipe 006 will be sampled at two locations" n Certain Teed property during representative rain events. These samples will be used to determine the pollutants contributed by each, LP and Certain Teed: Outfall #006 A - collect a representative sample from LP flow only. Outfall #006 B - collect a representative sample from Certain Teed flow only. OutfalI # 001 — Certain Teed Outfall # 002 — Certain Teed Wetlands and Stormwater Branch One 1617 Mail Service Center, Raleigh. North Carolina 27699-1617 North Carof i na Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-64941 Customer Service: 1-877-623-6748 Naturally Internet: www.r)cwaterquality.org Mr. Daniel J. Hurlcy CertainTeed Corporation—NCG070189 July 22, 2010 The monitoring must be submitted to the Winston Salem Regional Office and the Central Office. Contact George Smith at the Winston Salem Regional Office at (336) 771-5000 or Brian Lowther at the Central Office (919) 807-6368 for more information about the approval process. In accordance with your request for coverage under NCG07, we are rescinding your NCG21 Permit. Certificate of Coverage Number NCG200338 is rescinded effective immediately. Please take notice that this certificate of coverag is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirement:, to obtain other permits which may be required by the Division of Wafer Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other federal or local governmental permit that may be required. If you have any questions concerning this permit, please contact Brian Lowther at telephone number (919) 807-6368. Sincer,Ay, .for Coleen H. Sullins cc: Winston Salem Regional Office Central, Files Stormwater. Permitting Unit Files STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG070000 CERTIFICATE OF COVERAGE No. NCG070189 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisio.t of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, CertainTeed Corporation is hereby authorized to discharge stormwater from a facility located at CertainTeed Corporation 1149 ABTCO Rd North Wilkesboro, NC Wilkes County to receiving waters designated -is s Yadkin River and an unnamed tributary to the Yadkin River, class C waters in the Yadkin Fee -Dee River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, 11, 1I1, IV,'V, and VI of General Permit No. NCG070000 as attached. ' This certificate of coverage shall become effective August 27, 2010. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day August 27, 2010. �4 for Coleen H. Sullins, Director Division of Water Quality By the Authority of the Environmental Management Commission LUCATION MAi-P: ''r �,•'�::•'•, i', 1 . ,c `Y'_S� .`'`4" r _..1_ - 'yCrlc I .a' - - �,r �' , i`•r .i ^�:: - '; 1 \+ r .yl ! � r - I / {r�;.?t :4y -4°'r''A� � 11 I_ l � I i•r. �� � �� r _ -1 '�1,•I ss R ` � �� _ �,. c ; F -•l- tiNr } �1 y° ���'-i a �. j - - >t 1! '.� .`s � _ I • . Y - ,r ' A R ', Gru Il � -.1 r — � � -�.� ' + I:.s ). / _ a S t -.e 1 �•-�''.- �1 „<'�_.: r7 ..� r 'I. . - ,1 1 : �``'..,.+� �'c,�' r%' ! Vr 1 S ';- _l i Y •s``. •ti` +''} F :- . c L y i' r 1 - ` M1 r r- I -�J r� - r, :� : Jj .�' 1•. .=��:i!. _ •.a �'1 •r' I r .: • yS'• ICL'.Fi%''..:• , rt••.'t!" 1: 'I-. I i r�_ \ 1, r S s{ � • Nr'g.ep Ii r •F' . -' !- • r + 2umql IN 1 ( ✓ �' o8�7;i Iiliref r �'y :C Sl l t�rll' . _.r �-. ,r :•'tY '.�_:_ M :i_ w � te: _ y� �+r_��_ `"cr f iI i5 .�f ` •.I'.1, �I�:'f I�, 'l - �l i�,�•�-..�—.r --- ,I ��� Rl t� '+' _ ,.!''-^- •v'I�i r�a. r"t a .i. ! II 1 1'r ro •\ ` ri •� r d n\ — I t - t '- - - .t� t ` S`'Z ; • is l' � i; _r � 1 t � _ �; . - r%7 a 1'..., : � � _- '}f -.t �' r •. � � - Y @� I -. - -� �, v �- r2. - J S' `•'ii� li: _ i1 I �•':.» _ �� �, a�'�..-. _ �r�i`.- _��.1_• - .iS,l r •..- .,C`���.. ...i ,e -'�� ysU 1J' `• Y -::: 1 •r�~•�1'I��.y(-' -� r_- 1..Ir_l"__. � / t i �' � � _'�'��^�_I' r•��'ilV ' F!. 11 I •� .I I b JI•!I'•',��l.iG l tai FTeed Corpo atbn• 1 Srf• I ` r �1 -4 \ C��• _ _ •—r-�' �F :"z. --- _ ; ` i 'ss'�'. Y'.{"t FF-' _ �_ .41 V_L'J Cf :I P�,gj 77 ' ''%.:` -' '� •-'tom �li "�-,�,� �' -'; .I _ ` .s _ ��-�,' � _ -. _ ''I-- ,. `L y r 'ir ,at ��5 __� �J 4• t >I .`r- -� � r •� �, - :s .✓- I f - lr✓ti ` 1r Y .I V I i I+ a. It ;! -.. J t I L- � fi t_ JJ�ISI �- � I - t i _ `-•I rri = / _ _ ri '�'RS _ ' 6'.' � J �'I ;�: i\'' ',•i �} •ram � •� iF�.' -ram» ll k i '111.'v b.. i � _ �t e� I'r r 1,� • t• tom' I f'""-_•., f'� C � r .� . � 'I j', ' •, -; y�' �` '� ly ���_ : t '' -• ,.• rL� � \ ;!_- - .�i]Q��i�ER ri�.aC_I � � - ,;- l i rr, i 4 51! I,• �� -. t _ _ . ,, S . �L� i .: , i.. I - + I tl -,l ti' ��� I � Ir. `. � t - fl-; ..� - ''^� .j #1.1. f ... -, ,'1 �• 4'�5 - "-ti5 � I' -.- �'I`` 7.r_I` r o.�l� ��.J c. '__ - �.. � lJdlat Fars � I• ! .:= 4 i ,f�I� 'ir s f t ' l �':1�t- ;st _-�.,5L33�` :, 4 ���%y= �} `:r._#i •.�i-r•' r � r„�r � +Slti �r�'qI!}. - i- ✓ �i ? + l � + ....-��:_ - `i � `\y?' r J' I .•r fr, 's,- .'j�,z _ 4i r f{, 1 r' - y;. i,�,l' _ •• _ . I'"':'%t, �. = � f �1- 1 �L- — ' _ - - II ��+ r- . i r'r'- 1 r �' "a ,.+� NCG070189 Mti O Scale 1:24, 000 CertainTeed Corporation Latitude: 361 12' CO" N Longitude: 811 1' 5 2 " W County: Wilkes Receving Stream: Yadkin River and UT to lalkin Rivar Stream Oa3s: C Sub -barn: 03-07-01 (Yadkin Pee -Dee River Bain) Facility Location �+� NCDENR North Carolina Department of Environment and Division of Water Quality Beverly Eaves Perdue Coleen H. S611ins Governor - Director August 27, 2010 Mr. Daniel J. Hurley CertainTeed Corporation 1149 A13TC0 Rd North Wilkesboro, NC 28659 Natural Resources Subject: General Permit No. NCG070000 CertainTeed Corporation COC NCG070189 Wilkes County Dear Mr. Hurley: Dee Freeman Secretary In accordance with your application for a discharge permit received on June 25, 2010, we are forwarding herewith the subject certificate of coverage to discharge under the subject state NPDES general permit. This permit is issued pursuant to the requirements of North Carolina 'General Statute 143-215.1 and the Memorandum of Agreement between North'Carolina and thc: US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Additional monitoring for this site is Yequired because the analytical monitoring taken for the site's current permit (NCG210340) has values over the current benchmarks. This facility should be covered under'the NCG07 (Stone, Clay, & Glass) but has been covered under an NCG21 (Timber). Therefore, samples must be taken to determine if the parameters over the benchmarks are coming from stormwater associated with the CertainTeed Facility. The following analytical monitoring should be performed until the Winston Salem Regional Office has adequate data to show parameter benchmark exceedances are not because of stormwater coming from CertainTeed's facility. If the samples indicate that parameters are over the benchmarks because of stormwater coming from the CertainTeed site then an individual permit may be required at that time. y Required analytical monitoring: Analytical monitoring shall continue according to the NCQ''`, permit for COD, TSS, and pH. Pipe 006 will be sampled at two locations on Certain Teed ,property during representative rain events. These samples will be used to determine the pollutants.; t.'Qntributed by each, LP and Certain Teed: Outfall #006 A - collect a representative sample from LP flow only. Outfall #006 B - collect a representative sample from Certain Teed flow only. Outfall # 001 — Certain Teed Outfall # 002 — Certain Teed Wetlands and Storrnwater Branch Orie 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 North Carolina Location: 512 N. SaEshury St. Raleigh, North Carolina 27604 /r Phone: 919M7-63001 FAX: 919-807-64941 Customer Service: 1-877-623-6748 Natlrt-ally Internet: www.ncwaterquality.org ;/ Mr. Daniel J. Hurley CerrainTeed Corporation—NCG070189 July 22. 2010 The monitoring must be submitted to the Winston Salem Regional Office and the Central Office. Contact George Smith at the Winston Salem Regional Office at (336) 771-5000 or Brian Lowther at the Central Office (919) 807-6368 for more information about the approval process. In accordance with your request for coverage under NCG07, we are rescinding your NCG21 Perrnit. Certificate of Coverage Number NCG200338 is rescinded effective immediately. Please take notice that this certificate of coverag is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirement:, to obtain other pen -nits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other federal or local governmental permit that may be required, If you have any questions concerning this permit, please contact Brian Lowther at telephone number (919) 80726368, Sincerely, f for Coleen H. Sullins cc: Winston Salern Regional_ Office Central Files Stormwater. Permitting Unit Files STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCGO70000 CERTIFICATE OF COVERAGE No. NCC070189 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELII171NAT10N SYSTEM'[ In compliance with the provisio;, of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, CertainTeed Corporation is hereby authorized to discharge stormwater from a facility located at CertainTeed Corporation .1 1-49 ABTCO Rd North Wilkesboro, NC Wilkes County to receiving waters designated as Yadkin River and an unnamed tributary to the.Yadkin River; class C waters in the Yadkin Fee -Dee River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, 1I, III, IV, V, and VI of General Permit No. NCG070000 as attached. This certificate of coverage shall become effective August 27, 2010. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day August 27, 2010. for Coleen H. Sullins, Director Division of Water Quality By the Authority of the Environmental Management Commission LOCATIUN MAP: NCG070189 z- CertainTeed Corporation Lad Dade: 360 12'CO" N Lonoitude: 810 1' 52" W County: Weil kes RecEi%Jng Stream: 'Yadkin River and UT to YaJkin Ri-ver Stream (Jems: C Sub -basin: 03-07-01 (Yadkin FieE-Dee River Basin) YV13P 56d)te 1,-24,000 Facility Location