Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG020752_COMPLETE FILE - HISTORICAL_20120921
i STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /V GCo OaOqs:;� - DOC TYPE C�IISTORICAL FILE 0 MONITORING REPORTS DOC DATE ❑ O I � YYYYMMDD ALPIA ria NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, B.E. Governor Director September 21, 2012 CERTIFIED MAIL: 7009 0820 0000 2474 1909 RETURN RECEIPT REQUESTED G.S. Materials, Inc. Attn: Ronald G. Kirkpatrick PO Box 1335 Burlington, NC 27216 Subject: NOTICE OF VIOLATION (NOV-2012-PC-0328) RECOMMENDATION FOR ENFORCEMENT G.S. Materials, Inc. Riley II Pit, Certificate of Cove rag e-NCG020752 NPDES General Perm it-NCG020000 Barnett County Dear Mr. Kirkpatrick: Dee Freeman Secretary On September 20, 2012, Michael Lawyer, Environmental Specialist from the Fayetteville Regional Office of the Division of Water Quality, conducted a site inspection for the Riley II Pit facility located on Claude White Road in Harnett County, North Carolina. A copy of the Compliance Inspection Report is enclosed for your review. Mr. Jason Rollins, General Manager, and Mr. Sammy Reagan, Supervisor, were also present during the inspection and their time and assistance is greatly appreciated. Permit coverage authorizes the discharge of stormwater and/or wastewater from the facility to receiving waters designated as Cypress Creek, a Class WS-III waterbody in the Cape Fear River Basin. The site visit and file review revealed that the subject facility is covered by NPDES General Perm it-NCG020000, Certificate of Coverage-NCG020752. As a result of the site inspection, the following permit conditions violations are noted: 1) Qualitative Monitoring Qualitative monitoring has not been conducted and recorded in accordance with permit requirements. 2) Analytical Monitoring Analytical monitoring has not been conducted and recorded in accordance with permit requirements. Other Observations: Please refer to the enclosed Compliance Inspection Report for additional comments and observations made during the inspection. Requested Response: You are asked to respond to this office, in writing, within 30 calendar days from receipt of this notice. Your written response should include a reasonable explanation as to why the aforementioned violations have occurred as well as a Plan of Action to prevent these violations from re -occurring. Location: 225 Green Street, Suite 714, Fayetteville, North Carolina 28301 Phone: 910433-3300 4 FAX: 910486-07071 Customer Service: 1-877-623-6748 Internet: http:1/portal.ncdenr.orglweb1wq An Equal Opportunity , Affirmative Action Employer One NorthCarolina Naturall# ering sending a n for Thank you for your attention to this matter. This Office is these issues Your above-mentianedoresponse to thisabove, Y to the Director of the Division e Water Quality, regarding correspondence will be considered in this and an future violations aress. This office requires subjectto violations, cv I penalty assessment be properly resolved. These violations and y these matters, please of up to $25,000 per days o� e 9 violation. 3ould you have any questions regarding contact Mr. Lawyer or my E Sincerely, Belinda S. Henson Regional Supervisor Surface Water Protection Section BSH: ML/ml Enclosure cc: Jason Rollins, General Manager - G.S. Materials, Inc. (via e-mail) FRO - Surface Water Protection Section FRO - Land Quality Section Katie Merritt - WBS Compliance & Permits Unit DWQ Central Files Z Complete items 1,-2, and 3.'Also complete Item 41f Restricted Delivery is desired. pi Print your name and address on the reverse so that we can return the card'to you. ■ Attach this card to thb'back of the mailpiece, or on the front If space permits. I� I I I Article Addressed to: %11 , i l�'. i'�,`,ic'�T_T)f.:. A. Si I re-` / % X (/v[/J enf ❑ Addressee S. R ived ( ted Name) C. Date of Delixery D. Is deliverf address different from Item 17 ❑ Yes If YES, enter delivery address below: ❑ No r r : , j : 4, r I i) \ \ ( f 3. Service Type � rtifled Mail ❑ Express Mall i Cl Reglstered � Retum Receipt for Merchandise i ❑ Insured Mail ❑ C.O.D. j 4. Restricted Delivery? (Extra Fee) ❑ Yes 2. Article Number ?009 0820 0000 2474 1909 - (rransfer from servke mbar) Ps Form 3811, February 2004 Domestic Retum Receipt 102595 M-na lW j s Compliance Inspection Report Permit: NCG020752 Effective: 05/13/10 Expiration: 12/31/14 Owner: G S Materials Inc SOC: Effective: Expiration: Facility: Riley II Pit County: Harnett 696 Claude White Rd Region: Fayetteville Lemon Springs NC 28355 Contact Person: Ronald G Kirkpatrick Title: Phone: 336-584-1745 Directions to Facility: System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): On -site representative Jason Rollins Phone: 919-499-9322 On -site representative Sammy Reagan Phone: 919-499-9322 Related Permits: Inspection Date: 09/20/2012 Entry Time: 01:10 PM Exit Time: 03:27 PM Primary Inspector: Mike Lawyer/ Phone: 910-433 3304 Ext,23� Secondary Inspector(s): ILAu 3-V-10, Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Mining Activities Stormwater Discharge COC Facility Status: 0 Compliant i Not Compliant Question Areas: 0 Storm Water (See attachment summary) Page: 1 Permit: NCG020752 owner • Facility: G S Materials Inc Inspection Date: 09/20/2012 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Inspection conducted to ensure compliance with the conditions of the NCG020000 General Permit. Met with Mr. Jason Rollins, General Manager, and Mr. Sammy Reagan, Supervisor. An overall Stormwater Pollution Prevention Plan (SWPPP) has been developed to cover multiple mines that are owned and operated by GS Materials as they are all located adjacent to one another, but have coverage under separate mining and stormwater permits. Site specific information for each mine along with copies of the applicable Certificate of Coverage is also contained within the SWPPP. Documentation of weekly BMP inspections from July 2010 to present was reviewed. Qualitative Monitoring records were available for the second half of 2010, first half of 2011 and first half of 2012. All indicated 'No Flow' during a representative storm event. There was no record for the second half of 2011. An Annual Summary DMR for Analytical Monitoring for calendar year 2010 showed 'No Flow' for all basins. There were no records of Analytical Monitoring for 2011 or first half of 2012. Discussed monitoring requirements with Mr. Rollins who had worked at the mine several years ago, but just recently returned to oversee mining operations. After the records review, rode through the mine site with Mr. Rollins and Mr. Reagan to make observations of site conditions and basins. Expressed to Mr. Rollins that the site appeared to be in need of better operation and maintenance as several internal areas had experienced major erosion and some of the basins contained significant amounts of sediment. All sediment basins should be continually maintained so that any discharges are free of turbid water and/or sediment. Any accumulated sediment in the basins should be removed and the dimensions (length, width, depth) as well as outlet structures properly maintained so they function as intended. The establishment of vegetation is encouraged near and around the sediment basins and other areas where excavation or grading is not being conducted. U.S: Postal SeruiceT,., CERTIFIED MAILT,., RECEIPT (�omestic Mail Only; No Insurance Coverage Provided) Foy d'e_Ilvc iniormaYlon visit our wetrske at www.us s.com --" — ,� i � r y _ PS Form JOOO August 2008 SOI I orA Ins/nlctions Page: 2 Permit: NCG020752 Owner - Facility: G S Materials Inc Inspection Date: 09/20/2012 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ n n n # Does the Plan include a General Location (USGS) reap? ■ n n n # Does the Plan include a "Narrative Description of Practices"? ■ n D 13 # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ D n # Does the Plan include a list of significant spills occurring during the past 3 years? ■ n n n # Has the facility evaluated feasible alternatives to current practices? n D ■ n # Does the facility provide all necessary secondary containment? ■ D D Q # Does the Plan include a BMP summary? ■ D D 0 # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ n n D # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ D D n # Does the facility provide and document Employee Training? ■ n ❑ n # Does the Plan include a list of Responsible Party(s)? ■ n n n # Is the Plan reviewed and updated annually? ■ n n 0 # Does the Plan include a Stormwater Facility inspection Program? ■ n G 0 Has the Stormwater Pollution Prevention Plan been implemented? ■ n n n Comment: Qualitative Monitoring Has the facility conducted its Qualitative Monitoring semi-annually? Comment: No visual monitoring records for the second half of 2011, however records were available for the second half of 2010, first half of 2011 and first halt of 2012. All available records indicated 'No Flow' during a representative storm event. Analytical Monitoring Has the facility conducted its Analytical monitoring? # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? Comment: Only analytical monitoring record available for review was an Annual Summary DMR for 2010 that indicated 'No Flow' for all basins. Permit and Outfalls # Is a copy of the Permit and the Certificate of Coverage available at the site? # Were all outfalls observed during the inspection? # If the facility has representative outfall.status, is it properly documented by the Division? Yes No NA NE Yes No NA NE n■nn nn■n Yes No NA NE Page: 3 Permit: NCG020752 Owner - Facility: G S Materials Inc Inspection Date: 09/20/2012 Inspection Type: Compliance Evaluation Reason for Visit: Routine # Has the facility evaluated all illicit (non stormwater) discharges? Comment: ■DDD Page: 4 } ' -- GS Engineering Services, PLLC. July 27, 2010 Attn: Belinda Henson and Mike Lawyer NCDENR — Division of Water Quality — Stormwater Permitting Unit Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301 (910) 433-3300 . RE: NOTICE OF VIOLATION NOV-2010-PC-0836 - Hall-Rackley Pit (NCG020353) NOV-2010-PC-0837 - Cameron Pit (NCG020487) NOV-2010-PC-0838 - Riley it Pit (NCG020752) G.S. Materials, Inc. Lemon Springs, Harnett County, North Carolina Dear Ms. Henson and Mr. Lawyer: DEN --FRO JUL 2 8 2010 Please find enclosed a formal response to the above listed Notice of Violations (NOV) received from your office on July 15, 2010. We have discussed most of these issues with you in our meetings on site, but we would like to address them completely. G.S. Materials will ensure that these violations to the active stormwater permits will be addressed and brought up to date in full compliance over the next 6 months (end of Stormwater Monitoring Period 2). NOV-2010-PC-0836 - Hall-Rackley Pit (NCG020353) SPPP (Stormwater Pollution Prevention Plan) A SPPP has been developed and is currently being implemented by Karen Hilliard with G.S. Materials, who is acting as the responsible party for the SPPP. The management has adopted the plan and the on -site employees are being trained and informed of the SPPP currently. 2. SDO Qualitative Monitoring Qualitative monitoring will be conducted when analytical monitoring is being taken from each SDO (Stormwater Discharge Outfall): G.S. Materials has read over the monitoring report and is prepared to monitor throughout the rest of the sampling period. 3. SDO Analytical Monitoring Analytical monitoring will be conducted during the next sampling period (July 1 — Dec 31) from each SDO (Stormwater Discharge Outfall). G.S. Materials understands the parameters needed for testing and will be testing any discharges from the sediment basins on the Hall-Rackley Pit. GS Engineering Services, PLLC PO Box 2019 1104 W. Broad St. Elizabethtown, NC 28337 910, 862.3400 • Henson and Lawyer DWQ - Page 2 July 27, 2010 4. Other Items to Address G.S. Materials has obtained a rain gauge and started a schedule of weekly inspections by trained and informed employees of stormwater pollutants and runoff off -site. Sediment Basin inspections and any repairs are being documented. G.S.M. will be re -shaping the basins to provide for more defined sediment containment and to provide safe access to the outlets for testing and inspections. G.S.M. will re - vegetate side slopes to reduce sediment loads into the stormwater basins. G.S.M. understands that no stormwater pipes or connections shall be made into the closed - loop recycle system, which includes the silt ponds and the Duck Pond (Clearwater Pond) because no monitoring is required for that system. There are no stormwater pipes or discharges into the silt ponds or Duck Pond. If stormwater is piped or channelized into that system other than direct rainfall, G.S_M. knows that analytical monitoring must be performed because that is now "process water'. The closed loop recycle system does operate under normal everyday conditions with at least 2-feet of freeboard (depth from water level to top of the basins). NOV-2010-PC-0836 - Cameron Pit (NCG020487) SPPP (Stormwater Pollution Prevention Plan) A SPPP has been developed and is currently being implemented by Karen Hilliard with G.S. Materials, who is acting as the responsible party for the SPPP. The management has adopted the plan and the on -site employees are being trained and informed of the SPPP currently. 2. SDO Qualitative Monitoring Qualitative monitoring will be conducted when analytical monitoring is being taken from each SDO (Stormwater Discharge Outfall). G.S. Materials has read over the monitoring report and is prepared to monitor throughout the rest of the sampling period. 3. SDO Analytical Monitoring Analytical monitoring will be conducted during the next sampling period (July 1 — Dec 31) from each SDO (Stormwater Discharge Outfall). G.S. Materials understands the parameters needed for testing and will be testing any discharges from the sediment basins on the Cameron Pit. 4. Other items to Address G.S. Materials has obtained a rain gauge and started a schedule of weekly inspections by trained and informed employees of stormwater pollutants and runoff off -site. Inspections and any repairs are being documented. G.S.M. will be re- shaping the basins to provide for more defined sediment containment and to provide safe access to the outlets for testing and inspections. G.S.M. will re -vegetate side slopes to reduce sediment loads into the sediment basins. GS Engineering Services, PLLC PO Box 2019 1104 W. Broad St. Elizabethtown, NC 28337 910.862.3400 < -t e Henson and Lawyer DWQ - Page 3 NOV-2010-PC-0836 - Riley Pit (NCG020752) July 27, 2010 SPPP (Stormwater Pollution Prevention Plan) A SPPP has been developed and is currently being implemented by Karen Hilliard with G.S. Materials, who is acting as the responsible party for the SPPP. The management has adopted the plan and the on -site employees are being trained and informed of the SPPP currently. 2. SDO Qualitative Monitoring Qualitative monitoring will be conducted when analytical monitoring is being taken from the SDO (Stormwater Discharge Outfall). There is only 1 SDO on the Riley Pit. G.S. Materials has read over the monitoring report and is prepared to monitor throughout the rest of the sampling period. 3. SDO Analytical Monitoring Analytical monitoring will be conducted during the next sampling period (July 1 — Dec 31) from the SDO_ G.S. Materials understands the parameters needed for testing and will be testing any discharges from this sediment basin. However, this basin will probably not discharge. G.S.M. will submit a zero discharge for the sampling period if this is the case. 4. Other Items to Address G.S. Materials has obtained a rain gauge and started a schedule of weekly inspections by trained and informed employees of stormwater pollutants and runoff off -site. Inspections and any repairs are being documented. G.S.M. will continue to maintain this basin's shape and re -vegetate side slopes. In conclusion, we will work with G-S. Materials as they implement the SPPP and monitor the sediment basins found on the Hall-Rackley, Cameron, and Riley-11 Pits. We will provide you with a copy of the monitoring reports from the basins before we submit to the Raleigh Central files. G.S. Materials will be brought up to date in full compliance over the next 6 months (end of Stormwater Monitoring Period 2). Thank you for all your help and advice as G.S. Materials works to comply with the stormwater permits. Sincerely, GS Engineering Services, PLLC. �zxY J. Branch Smith, PE Consultant for GS Materials, Inc. Cc: Karen Hilliard, GS Materials GS Engineering Services, PLLC PO Box 2019 1104 W. Broad St. Elizabethtown, NC 28337 910.862.3400 ®L T� • a - NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director July 15, 2010 CERTIFIED MAIL: 7009 0820 0000 2473 7926 RETURN RECEIPT REQUESTED G.S. Materials, Inc. Attn: Ronald G. Kirkpatrick PO Boa 1335 Burlington, NC 27216 Subject: NOTICE OF VIOLATION (NOV-201,0-PC-0838) C.S. Materials, Inc, Riley II Pit NPDES Stormwater General Permit-NCG020752 Harnett County Dear Mr. Kirkpatrick: Dee Freeman Secretary On June 29, 2010, Michael Lawyer and Belinda Henson from the Fayetteville Regional Office of the Division of Water Quality conducted a site inspection at the Riley lI Pit facility located on Claude White Road in Harnett County. North Carolina. A copy of the Compliance Inspection Report is enclosed for your review. Ms. Karen Hilliard, Office Manager, and Mr. J. Branch Smith, PE with GS Engineering Services, were also present during the inspection and their time and assistance is greatly appreciated. Stormwater and/or wastewater from the facility drains to Cypress Creek, a Class WS-III water located in the Cape Fear River Basin. The site visit and file review revealed that the subject facility is covered by NPDES Stormwater General Permit-NCG020752. Accordingly, the following observations and/or permit condition's violations were noted during the Division of Water Quality inspection: t) Stormwater Pollution Prevention Plan (SPPP) A Stormwater Pollution Prevention Plan (SPPP) has been developed, recorded, and properly implemented. Yes ❑ No ® (see Summarv/Comment on inspection report regarding implementation) 2} Qualitative Monitoring Qualitative monitoring has been conducted and recorded in accordance with permit requirements. [Yes ❑ No El Location: 225 Green Street, Suite 714, Fayetteville, North Carolina 28301 Phone: 910-433-33001 FAX: 910-486-07071 Customer Service: 1-877-623-6748 Internet: www.ncwateraualitv.ora An Equal Opportunity 1 Affirmative Action Employer 3) Analytical Monitoring Analvtical monitoring has been conducted and recorded in accordance with permit requirements. cs❑ No■ Other Observations: Please refer to the enclosed Compliance Inspection Report for additional comments and observations made during the inspection. ReQuested Response: You are asked to respond to this office, in writing, within 30 calendar days from receipt of this notice. Your response should include a Plan of Action to address the aforementioned violations as well as a reasonable time frame that you expect to be in full compliance with the conditions of the NCG020000 general permit. Thank you for your attention to this matter. This office requires that the violations, as detailed above, be properly resolved. These violations and any future violations are subject to a civil penalty assessment of up to $25,000 per day for each violation. Should you have any questions regarding these matters, please contact Mr. Lawyer or myself at (910) 433-3300. Sincerely, Belinda S. Henson Regional Supervisor Surface Water Protection Section BSH: ML/ml Enclosure cc: Karen Hilliard, Office Manager-G.S. Materials, Inc. {via e-mail) J. Branch Smith, PE-GS Engineering Services, PLLC (via e-mail) FRO -Surface Water Protection NPS-Assistance & Compliance Oversight Unit DWQ Central Files CofLETE�THIS SECTION COMPLETE THIS SECTION ON DELIVERY, 1 ■ Complete items 1, 2, and 3. Also complete A. Signature I item 4 if Restricted Delivery is desired. ❑ Agent 1 ■ Print your name and address on the reverse X Z�L ❑ Addressee so that we can return the card to you. B. Received b (Printed Name) C. Date of Delivery ■ Attach this card to the back of the mailpiece, or on the front if space permits. D. Is bei ryaddress different from item 1? ❑ Yes 1. Article Addressed to: ` y aI�YE$,,%4ter delivery address below: ❑ No G S MATERIALS INC G MR ROtiALD G KIRKPATRICK � �� �� s POST OF ICE BOX 1335 BURLiNCTON NC 27216 � � ✓ -s i 3. S ice Type . rti lied Mail ❑ Express Mail Registered ❑ Return Receipt for Merchantllse { I ❑ Insured Mail ❑ C.O.D. ' ! 4. Restricted Delivery? (Extra Fee) © Yes 2. Article Number 7009 �0820 00011. 2473.' 7926_� —� t {Transfer from service labeo PS Form 3811, February 20134 Domestic Return Receipt 102595-02-M-1W Compliance Inspection Report Permit: NCG020752 Effective: 05/13/10 Expiration: 12/31/14 Owner: G $ Materials Inc SOC: Effective: Expiration: Facility: Riley II Pit County: Harnett 696 Claude White Rd Region: Fayetteville Lemon Springs NC 28355 Contact Person: Karen Hilliard Title: Phone: 919-499-9322 Directions to Facility: System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): On -site representative J Branch Smith Phone: 910-862-3400 On -site representative Karen Hilliard Phone: 919-499-9322 Related Permits: Inspection Date: 06/29/2010 Entry Time: 10:00 AN) Exit Time: 01:00 PM Primary Inspector: Mike Lawyer Phone: 910-433-3,38t1` Secondary Inspector(s): Belinda S Henson Phone: 910-433-3,300Ext-W 9 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit inspection Type: Mining Activities Stormwater Discharge COC Facility Status: ❑ Compliant ■ Not Compliant Question Areas: ® Storm Water eD. n- ru a— r� (See attachment summary) Postage ru Certified Fee 0 Postmark p Return Receipt Fee Here O (Endareamenl Required) //'� C3 Restricled Delivery Fee Qr%2 e (,,,,0. 0 (Endorsement Required) coTotal Postage & Fees r$ O sent 71 a er,' . rus.; ... � "° C. .. OTC..��.3-3---_----------------- state r +a � r.�. Page: 1 Permit: NCG020752 Owner - Facility: G S Materials Inc Inspection Date: 06/29/2010 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Inspection conducted to ensure compliance with the conditions of the NCG020000 general permit under its current effective dates as well as previous coverage for the facility. Met with Ms. Karen Hilliard, Office Manager, and Mr. J. Branch Smith, PE with GS Engineering Services, who has developed a Stormwater Pollution Prevention Plan (SPPP) to cover multiple mines owned and operated by G.S. Materials, Inc. The SPPP is complete, however there is no documentation of the required weekly BMP inspections, monitoring data, maintenance activities, etc., which constitutes failure to implement the SPPP. The Riley 11 Mine (NCG020752) consists of approximately 59 acres. Material is excavated and transported across Highway 24/27 to the Hall-Rackley Mine for processing. There is one large stormwater basin with a rock weir and no mine dewatering. At the time of inspection, there were no records of inspections or Analytical/Qualitative Monitoring data. If there are no discharge events during a monitoring schedule, the DMR's should be completed with 'No Discharge' noted under the monitoring results area and submitted to Central Files. Page: 2 Permit: NCG020752 Owner - Facility: G S Materials Inc Inspection Date: 06/29/2010 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ D D D # Does the Plan include a General Location (USGS) map? ■ Cl D D # Does the Plan include a "Narrative Description of Practices"? ■ D D D # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ D D D # Does the Plan include a list of significant spills occurring during the past 3 years? ■ D D Cl # Has the facility evaluated feasible alternatives to current practices? D D ■ D # Does the facility provide all necessary secondary containment? D D D ■ # Does the Plan include a BMP summary? ■ D D D # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ D D # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ D D D # Does the facility provide and document Employee Training? ■ D D D # Does the Plan include a list of Responsible Party(s)? ■ D D D # Is the Plan reviewed and updated annually? ❑ ❑ ❑ ■ # Does the Plan include a Stormwater Facility Inspection Program? ■ ❑ D D Has the Stormwater Pollution Prevention Plan been implemented? D ■ ❑ D Comment: Although an SPPP has been developed and contains all permit -required components, the lack of documentation of monitoring an inspections constitutes failure to implement the SPPP. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? D ■ D D Comment: Documentation of Qualitative Monitoring could not be produced at the time of inspection for the current or previous permit cycle. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ ■ ❑ D # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? D ❑ ■ D Comment: Documentation of Analytical Monitoring could not be produced at the time of inspection for the current or previous permit cycle. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ D D D # Were all outfalls observed during the inspection? ■ D D D # If the facility has representative outfall status, is it properly documented by the Division? D D ® D Page: 3 Permit: NCG020752 Owner - Facility: G S Materials Inc Inspection Date: 06/29/2010 Inspection Type: Compliance Evaluation Reason for Visit: Routine # Has the facility evaluated all illicit (non stormwater) discharges? Comment: ■ 0 0 0 Page: 4 NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director May 13, 2010 Ronald Kirkpatrick G S Materials Inc PO Box 1335 - Burlington, NC 27216 Dear Permittee: Dee Freeman Secretary Subject: NPDES Stormwater Permit Coverage Renewal Riley II Pit COC Number NCG020752 Harnett County Your facility wac granted coverage under stormwater general permit NCG020000 on 81712009. This letter serves as notice that the Division of Water Quality (DWn) has reis:_ued the general permit and that your facility's cov--r,-r., will contin.-te under the conditions of the reissued general permit. Please review the new permit to familiarize yourself with the changes in the reissued permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated October 15, 2007 (or as subsequently amended). The following information is included with your permit package: • A new Certificate of Coverage • A copy of stormwater General Permit NCG020000 • A copy of a Technical Bulletin for the General Permit • Two copies of the Tier 21 Exceedence Discharge Monitoring Report (DMR) Form for Stormwater • One copy each of the Annual Summary DMR Forms for Stormwater and Wastewater • Two copies of the Limit Violation DMR Form far Wastewater • Two copies of the Qualitative Monitoring Report Form The General Permit authorizes discharges of stormwater and wastewater, and it specifies your obligations with respect to discharge controls, management, monitoring, and record keeping. Please review the new permit to familiarize yourself with all the changes in the reissued permit. If your Certificate of Coverage (COC) restricts authorization to discharge stormwater only (or other limited terms) based on your original application, or subsequent modifications to your COC, you must continue to meet these requirements or contact the Stormwater Permitting Unit to request a modification of this renewal COC. The more significant changes in the General Permit since your last Certificate of Coverage include the following: Part 11: • Section B - Language referencing PAMS has been changed. Flocculants may now be used if evaluated by the Division and administered in accordance with maximum application doses and other requirements. Part III: • Section A - The permit now requires a Stormwater Pollution and Prevention Plan (SPPP) tailored to the mining industry, in lieu of a Stormwater BMP Plan. • Section A - Inactive rnines may be inspected on a reduced schedule: at least once per month and after 0.5" (or more) of rain, To qualify, inactive mines must possess an "Inactive Renewal" from DLR or certify to DWO the site has been stabilized. The permittee must notify the DWQ Regional Office of inactive status. Discharges from inactive mines must still be monitored on the same schedule as active mines. Wetlands and Stormvrater Stanch 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 0I1e location: 512 N. Salisbury St. Raleigh, North Carolina 27604 North Car011 I a Phone: 919-807-63001 FAX: 9IM07-64941 Customer Service: 1-877-623-6748 �7 Internet: vvww. ncwaterqua lity.org Ast-i'haal%% t �/ An Equa! OpporlurOr. i..'J irmative Action Employer ii// �/ Permit Reissuance — Permit Number NCG020752 May 13, 2010 Page 2 • Section B — Revised provisions require that stormwater discharges be sampled twice per year (instead of annually), and that the sampling results be compared to new benchmark values. (The previous cut-off concentrations have been removed.) • Section B -- Revised provisions require the permittee to execute Tier One, Tier Two & Tier Three response actions, based on the first benchmark exceedence (Tier One) and the second consecutive benchmark exceedence (Tier Two). Tier Two requires that the permittee institute monthly, ;monitoring (reported to the appropriate Regional Offices) instead of twice -per -year monitoring. Mont: =':y monitoring shall be done until three consecutive monitoring events show no benchmark exceedences. • Section B — This part contains a new provision that four exceedences of any benchmark will trigger increased DWQ involvement in the permittee's stormwater management and control actions. C3'-YVQ may direct the permittee to apply for an individual permit, institute specific monitoring, or may direct :he implementation or installation of specific stormwater control measures. • Section B — The definition of "Representative Storm Event" (RSE) now allows 48 hours (instead of 72 hours) of little or no precipitation to precede an RSE. • Section B — Stormwater discharges from a basin designed to contain the 10-year storm must now be monitored. • Sections B & C — Failure to monitor according to permit terms triggers monthly monitoring for the remainder of the permit. • Section C — Analytical monitoring for Total Petroleum Hydrocarbons (TPH) has replaced the Oil & Grease parameter in the previous permit. • Section D — Qualitative monitoring must now be conducted during the same representative_ storm event as the analytical monitoring. • Section D — The permittee is required to keep a written record of his response to problems identified by his qualitative monitoring observations. • Section D — If the permittee fails to respond effectively to problems identified by qualitative monitoring, the permittee may be required by DWQ to perform corrective action. • Section D — Qualitative ROS: Representative Outfall Status may be granted for qualitative ,monitoring for some Stormwater Discharge Outfalls (SDOs). • Section D — If mines do not respond to problems seen in visual monitoring, DWQ may now require that mines change the monitoring frequency, apply for an individual permit, implement in -stream monitoring, install or modify structural stormwater controls, or implement other controls. • Sections B, C, & D — Inability to sample due to adverse weather must be reported in the SPPP and recorded in the Annual Summary DMR, • Section E — A lower TSS Wastewater limit for PNA waters is included in the permit. • Section E — All mining operations are now required to monitor TSS in wastewater effluent discharges (not only industrial sand mines). However, TSS limits only apply to industrial sand mining operations. • Section E — Turbidity limits on effluent discharges have been removed; however, turbidity standards still apply in the receiving waters. • Section E — Approval of a Pumping O&M Plan may be required prior to coverage (for sites with dewatering activities that have the potential to drain wetlands or other surface waters). • Section E — ATC Requirements have been changed for clarity. These requirements are now outlined for Mine Dewatering Wastewater, Process Wastewater, Overflow From Non -Closed -Loop Process Recycle Wastewater Systems, and Overflow From A Closed -Loop Process Recycle (CLPR). • Section E — Monitoring for Fecal coliforms in discharges to SA waters has been clarified. Fecal coliform monitoring is now required for all process and mine dewatering wastewater discharges to SA waters. • Part IV: • Section E — Items 1. and 2. require submittal of a new reporting form: the Annual Summary DMR. This annual summary of the anal monitoring results should be submitted to the DWQ Central Office by March 1 of each year. • Section E — Exceedences and violations must be sent to the appropriate DWQ Regional Office within 30 days of receipt from the lab. • Section E — Results of "No Flow" or "No Discharge" must be recorded within 30 days from the sampling period in the SPPP. "No flow" or "No Discharge" must also be reported on the Annual Summary DMR form. Permit Reissuance — Permit Number NCG020752 May 13, 2010 Page 3 Your coverage under the General Permit is transferable only through the specific action of DWQ. This permit does not affect the legal requirements to obtain other permits which may be required by DENR, nor does it relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact these members of the Stormwater Permitting Unit: Jennifer Jones at (919) 807-6379 or Bethany Georgoulias at (919) 807-6372. Sincerely, fafr Coleen H. Sullins cc: DWQ Central Files Stormwater Permitting Unit Files Fayetteville Regional Office STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020752 STORMWATER, MINE DEWATERING WATER AND/OR PROCESS WASTEWATER NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with -the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, G S Materials Inc is hereby authorized to operate approved wastewater treatment system(s) and discharge stormwater and/or wastewater, as approved in the original permit/application or subsequent permit modification, from a facility located at: Riley II Pit 696 Claude White Rd Lemon Springs Harnett County to receiving waters designated as Cypress Creek, a class WS-111 waterbody in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, 111, IV, V, and VI of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective May 13, 2010. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this 131h day of May, 2010.- �'2"L / �� for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission � v, o Z V757 GS 1104 W BROAD ST P.O. BOX 2019 ELIZABETHTOWN, NC, 28337 (910) 862-3400 FAX (910) 862-3410 TO: Brian Lowther NCDENR - Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (910) 807-6300 Fax (910) 807-6495 LETTER �F TRANSMITTAL DATE 0811 8109 JOB NO. ATTENTION Brian Lowther PHONE 40 919 807-6300 RE: Riley Pit NPDES Permit Riley Pit, GS Materials, Inc. Lemon Springs, NC I I COPIES DATE NO. DESCRIPTION 1 3 11 x 17 Mine Maps REMARKS: Please let me know if you need anything else. COPY TO: File SIGNED: J. Branch Smith, PE No ' T----- E LM1. MINE BpINpARY r PROPeRTY BWNaARI E.ISTI44 cokroLp ' =20 = PROM 0 00NTOLP 60JGININ6 PROPERTY LINe r f r rr�r.��.Iawa.r r.a� E r�r OVrr WAMM +6 .......... ........... .......... U- r1•_ �� �/s 'i f � r�A L L� _ J y � AIeTAEIBQ' A990QliEy W t t +iYl- R RL'C aw . 1. „L, PEWT 43-,E R..y SEDRf'FeNT POND Existing Conditions Max Okho anm 20 Au" Req*e6 Sedment Stooge' O.B3 Acre-ft. water Storog6 Ydume: 8.94 Acre-H. tO-Y-ar RwpH vdwne; 7.70 Acra-N, 25-Year Runoff volume; 10.38 Acre-fL 0-25 year outlet d•Ischorge: 13 CFS Future Conditions Max. Disturbonce: 54.9 Aces Requred Sediment Storage: 2.27 Acre-ftB� { ru4e water Storage volume: 7 o=ow lct aBet eleroul ona o1 Jtl9 ft. Xca5vaom-ft storage) ID-Yeor Runoff Yalurm 15.2 Am-ft. 25- Year Runoff Volume: 19.8 Acre-1t 0-25 year outet dhxhorge: NONE r f ' SECTION A r I RE-ESTABLISH ]D' VEG. BUFFER AND RE -GRADE Ex1STWG BERM Stone Outlet Filter Section (NTS) -------------- MINE BOUNDARY PROPIRTY eauNaARY "ISTING C0 OIJ2 - 20 PROFt-AD COMTOIR GrEttSrikO ---- A0101NIN PROPERTY wrl td.d Crallrs.cbr• w irRrin�salw�v� .Ace° M - Gli®.IC 1 OMIOIOIiµ �„�� ('II IR1A7•➢ R7aI A,T . NPue`J RDI) Bryn .1NC 4A' , aBNr r sEcncw c ~_ WW1' 24/27 ��,.► Eeo' Puietrr ww1 L f " \ GRADE SLOFES-- ` ,� t • 1 OR FLATTER _ \\ '1 No I nmo ` \�\ A A � -mad'■ r#,7V S� -, A. Sh.. 01" S-t- RBUFFER � • L ,i`~ (S46 Baton ob—) t. RE-ESTABLISH �1 W VEG SUFFER .1 / Ij Afar 1tElEAlo A6 AND RFC -GRADE f 1 JB BERM MAP 2 PROPOSED MODIFICATION 1 e A A7111 R �AS9A0�(01AI= LP l4LLL 43'r I Pmioe-r ire F'nd NBtBr ShW Ana SFK L-212 TiY m"NGe, Oro . £# rlvyym fm ft o01.OR. Ala Eere+m-a f4�ES GNLr, Axp ARE IUT role NEmrmeR: DE LlWL PIFP[RES. 0 / 2 V z w Q Jao _ BlBrlr c J La LLI J W a_ Lm f V� cc W d J J Q=,w,{{ Y "p N O .� Z 01N N o ujiyy� Z muj ul U m �cc U.1 w C N aas o 0 yM N N � � O LU �xx I-- u_ %' I rA6 I arms 6 S MATERIALS, INC. PERMIT 43-11 HARNETT COUNTY, NC M. n NONr,c nrl2aaO .air W JMT . 7 1 ¢r 3 RILEY PIT II RENE*AL S-1 MINE MAP RILEY ti 2 PIT MINING PERMIT 11 43- 1 1 r --------- - -------------- HARN =TT COUNTY SOILS MAP ORIGINAL PERMIT MAP 3-D TOPOQUAD NCDOT VICINITY MAP HARNETT COUNTY PARCELS LEGEND ,v`o',A—j%4wwwFumT- .x 1 a z H Z , o' o W ✓� rH U N U fib} Z N l 0U) IL m U CC W w OLa to 0co �o N M n O N N q ,q •o O cn m O: o 0 alP L oW� G S MATERIALS, INC. PERMIT 43-11 HARNETT COUNTY, NC eu�[ /S NOTED rwr n kR awrm .MT NOV. 2007 a[it rw 2 OF 3 ocvm JWT awes io S-2 lwT RN_E'l II F4T RENEwAL rJ 1♦m HW j.pl Fµp !Nm .rm 7ada dapp .Wa IMm 1,aW r}sap 131aP SECTION "B" MINE CROSS -SECTIONS W MA %'MATO IIFM low v[yETA1Ep pvE>sAl}I pl NfDIN TAT1 V sr. = N 6 IDOL Ail. Tm 4w, AVL 4" i1 V RTITDI OF PEW - 3r2•e AVE 410 •tit 7F00 1.00 swp 10.0a ,1,4* 12-00 TSWO 14s00 16.00 1e.40 57-M Ta.W SECTION "C" 1. AOOWLME WM-LGE 7 M .] .rN eWSWED MW S. OOO®i OF OMiQ P/D- 7HOOIeBer a . eMlel Walk +2 FOM Wel"AA ON AA1 MORN AT ALL POMIS OF ttd: vowo AAP bait" E A M Awk WHEMMA 6 OWATEA. U3.7e! m KID 404LW T. Lg 110wwt�WW DE DO S"oKlI1EfTawwx MCAN Wf O M wvR ar r"Mc mw1L'AAOM vptYala PIaQ tcw WJWW -M Veep 40M AND e7F,ww.Cta Ar 0LW`M T 10% SET7LEWEPir 3' APFL s I�tlre�-s+ - . �SLLpppp[[ 7Tpp IKNdEE CROSS SECTION OF OPEN PIT — DIVERSION BERM r-r im noli QQW7MX JaV sPmFTodT n S FUR TEMP aERW 1. RDXM ALL TREES. BRUSH AM STUMPS FMM DNMtSM FDUNWT". CROSS SECTION OF SECTION OF EXCAVATION AREA AREA q FM . CONSTRUCT �10 x GRAVEL CONSTRICTION r 1 COMPACT FaDQE BY WHEV-5 OF CONSTRUCTIOW EaAPMENr. ENTRANCE DETAIL OR tfl) ERR AT ALL PPOkK . THE TOP OF TME oNERstow a ON oESIorN OWE 5. SEED AND MULCH IMMEDIATELY AFFER CONSTRUCTION. SEE NOT TO SCALE VEDETATEIN PILM. CONBTRt1CT10N SEDUENCE. i1 �raeal upgrvde exho'pgowwvocUan 3, inelan -11.1 ftructun for ndlnent pond Per design. a- Repair one r.-grado apan-pA berm mound o cowtlun areoe, ualnq tnp"l to prepon bap B- of !berm uxfaeee. 5. Grade a.l.tinq mk4 We to drdn entirely to excavation area and oxh" sediman ent pel. S, Install IocWnq ebb " at nhw enlronw. 7, Pm— .eedbo.* e.ed and Auld, Oe"ne a..d aanplet.d Indne m.a. In obowdonce aith Ye90AUM Plon. e. W,*W •OPEN& PW .amhq ." areemd P..tnet.r at nNr. 9, Maintaln/degrade/r.cJatn buNen not meeting mAKmWn criteria. 10. MAr exm.atlon mmplded. nxnor a. temporcrT' rneoe,Irw. nprpde Bide par Rrclmrwtlpn PWn. Napa e..dbede. aretl ie.lpE v a r n IA accadmr .i<t, tn. 1Fagatodon P1on. 1T- When Paid Awe rtebdt2ad, sbxk rlttl w,bW ban qd br— at robe econunended by a wW%d kWo bbiogtat. TI RIPORARY SEBDNO i MULCHING SPEC FICATICN-S dP..e.. Rr. ,nda..i A,. SnlpN .IKaa!a P.ynq-I .el1y..lar lisp, Karen Ir Aex+.>RI FQ Orw Km.W aatK'Q when Woon o1 wroDr y row a w .,d 5e/.+.I .,-. Manli.-Abart'F_W be Fo ,S • MN 16 udL 750C k.e, rep U My , Paren t . Lk" I Coaol P'i"-Fl.c, t -APF 15 SaP ww srr Fdt'w. Iecellw.w+dMa,e r .at b k a .wv 2.am Men. va a�e,E,rx ar,rera and 7m bf ,GAOAO Ira1Aa 'AeMlldeae4,wa,n rreF.aea.te ke.eee, .r.re+wb•.•,a.la aae�,rn.p. PFRMANEN7 SEEDING A MULCMNG SPECIFICATIONS (NCDENA SEC MANUAL -TABLE d-1111 Ter lerr sops :. aw . anll W. B�••usapa. •ry m .drp Ky..bw X ,v Pnl�l Mllesf u.na+W.r+.we.�sey.NK3�a. .rlRer. b1-W ,S arm.+ I,PPyr..rrr. msa a..n.rw a w.+r 7Om w.ae p..ryt.Ar..�.r.lpYYee q.16 ,a I.I..Iw wl.rr.e.rraAr rlepe.a...w,. I ..r..lwrarrwr.r..Tw .eN..., .asset r..r.w.r.a........ 'llrlr n AFP,b.O4 e.r..l �rra ACREAGE DATA CATEGORY AFFECTED ACREAGE TAI0hWSEDIKENT PONDS 1.5 STOC l"s 2 O w.sTfown 2.0 PwoctSSNi ARWHA AD 1 O mNc E.eA AT1an 49.5 TOr4 AFFECTED ACAt, 5b Amu Wonm PpaaIr ftftm✓<. 59 t MINE OPERATOR G.S MATERIALS, INC PO BOX 1335 BURLINGTON. NC 27216 TEA, W9-_"w9322 FAX 919-499-2097 P90PERTY OWNER KIPKPATRICII ASSOCIATES, LP PO BOX 2570 BURLINLTON. NC 27216 TEL 336-5SL-I%S SEAL ,-2= 4 N V J J d Z W ii C4 �y cc p gg Z1° E .V OW IN 60 zN x(' 2 I.-J wu 06 Q W to ht Q I�iI wLU N O o�m o b m 411 #a �F>L .man ,nEc G.S. MATERIALS, INC 'RILEY 11 PIT HARNETT COUNTY, NC w,wl er ra arms ace K. IMT NOV 2007Z OF .eao rra� r JWT JWT DET• 1 .a6r wi RILEY a PIT aEREWAL r . North Carolina Beverly Eaves Perdue Governor Karen Hilliard G. S. Materials, Inc. PO Box 1335 ' Burlington, NC 27216 Dear Ms. Hilliard: 4 A W i1-V;VA NCDENR Department of Environment and Natural Resources Division of Water Quality Coleen H. Sullins Dee Freeman Director Secretary August 7, 2009 DES V R"FRO DWO Subject: General Permit No. NCG020000 Riley It Pit COC NCG020752 Harnett County' In accordance with your application for a discharge permit received on July 11, 2009, we are forwarding herewith the subject certificate of coverage to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. Please note that the attached permit expires on December 31, 2009. Your COC will be automatically renewed to cover the full 5 year term of the soon to be reissued permit. In the interim you must abide by the terms of the expiring permit. You can review the proposed general permit changes at (www.ncwaterquality.org/su/publicnotice.htm). This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other federal or Iocal governmental pen -nit that may be required. If you have any questions concerning this permit, please contact Brian Lowther at telephone number (919) 807-6368. Sincerely, cc: Fayetteville Regional Office Central Files Stormwater Permitting Unit Files Wetlands and Stormwater Branch 1617 Mail Service Center, Ralegh, Nash Carolina 27699-1617 Location: 512 N. Salisbury St. Ralegh, North Carolina 27604 Phone. 9I M07-63001 FAX: 919-807-6494 \Customer Service: 1-877-623-6748 Internet: www.ncwaterquaiiry.org An Equal Opportunity 1 Affirmative Action Employer ORIGINAL SIGNED 13Y for Coleen H. ipFCK North Carolina ;Vatutally STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020752 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, G. S. Materials, Inc. is hereby authorized to discharge stormwater from a facility located at Riley II Pit 696 Claude White Rd. Lemon Springs Harnett County to receiving waters designated as unnamed tributary to Cypress Creek, a class WS-III water in the Cape Fear River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, III, IV, V, arid VI of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective August 7, 2009. This Certificate of Coverage shall remain in effect for the duration of the General Pennit. Signed this 71h day of August, 2009. ORIGINAL SIGNED. BY KEN PICKLE for Coleen H. Sullins., Director Division of Water Quality By the Authority of the Environmental Management Commission LOCATION MAP: NCG020752 \J 1�7 t M� Stale 1:24,a?O G.S. Materials, Inc. Riley II Pit Lad tude: 3511 0' 59 N Longibade: 7911 9' 55" W County: Harnett Receiving Stream; UT tD Cypress Creed; Sieam 0ass: VVS-III Sub-basn: 03-06-14 (Cape Fear River Basin) Facility Location maearm NCDENR North Carolina Department of Environment and Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director August 7, 2009 Karen Hilliard G. S. Materials, Inc. PO Box 1335 Burlington, NC 27216 Natural Resources Subject: General Permit No. NCG020000 Riley II Pit COC NCG020752 Harnett County Dear Ms. Hilliard: Dee Freeman Secretary In accordance with your application for a discharge permit received on July 11, 2009, we are forwarding herewith the subject certificate of coverage to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. Please note that the attached permit expires on December 31, 2009. Your COC will be automatically renewed to cover the full 5 year term of the soon to be reissued permit. In the interim you must abide by the terms of the expiring permit. You can review the proposed general permit changes at (www.ncwaterqualitv.org/su/publ i cnotice.htm). This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other federal or local governmental permit that may be required. If you have any questions concerning this permit, please contact Brian Lowther at telephone number (919) 807-6368. Sincerely, OkIGINAL SIGNED BY KEN PICKLE for Coleen H. Sullins cc: Fayetteville Regional Office Central Files Stormwater Permitting Unit Files Wetlands and Stormwater Branch ape 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Not-1 h.Carolina Location: 512 7 Salisbury St. Ral19-80 h, North494 \ Carolina r Service: Phone: 919�07-63001 FAX:919-807-64941 Customer Service: 1-877-623-6748 f Internet: www.ncwaterquality.org An Fqual Opportunity 1Affn-nativeAaon Employer STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020752 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the. Federal Water Pollution Control Act, as amended, G. S. Materials, Inc. is hereby authorized to discharge stormwater from -a facility located at Riley II Pit 696 Claude White Rd. Lemon Springs Harnett County to receiving waters designated as unnamed tributary to Cypress Creek, a class WS-III water in the Cape Fear River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V, and VI of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective August 7, 2009. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this 7'h day of August, 2009. ORiG�EN PICKLE SIGNED BY for Coleen H. Sullins., Director Division of Water Quality By the Authority of the Environmental Management Commission LOCAT[ON MAP: =\'Sa �! ��' ram.• -_'"-') +..- � S* � � .,.,, I 3� �- 1jil xYr... ji5 �-.5�-✓'y' s �Y1"5'% JFj�Sr� ,}�_�s �� FTYf� ! )1�� 3: *'Q�/��/al i,r'•�J-�.a ^."'�., ro��.r,� IA'rred f� 14 J 't' ram' y� "'^ } �t fr r� ��-? � � -� E^ It +��Z'✓� 1I / J" } �•,✓f ���' �' �{.`�t` li �'a{f�}; • fir% —fit ;i< � � ` r , � r '�� `.-'� .tc•u -� e 5 1- ti �,. ��• f"s ix l ,� � ai lCri �/.t{ �13���,�.��5 tiL�-�!1 e S��/ifi)� ti+�1]�I��' c { `tt ��:•• 'T�i':.-i�1• v 1'n ��: t/5 ,a,s I � .I\ ..✓^-� t d +'i` SK'a r - f I{'•C ���¢ `�-�� � -. �d 1 {R� �y F T ���✓'� � - �,�` (`� /. f,(� ���}Ir.J �'.,�� �� M.� a4IJ SYr �7` ?ETI �. � f.-i� < r S \ [ a"`_ r W F (•-,j..c` S t l r r i�, " � ?M � C 5 7 � w ✓ ,r r� J 'ri r j � f�41i^,>; � r Ir �- . iii f r-:w��y � � v`--`t�.-'•'7 -.r r ! q \ ' � ♦ \. c �a ��V `�,l��`� ^ rt � � ,� ._ t- r f $ ` r '•. �_:. s C r*�.- sly. \ L+ti1:k S+. 1 r r S + r,, ti.� 1 ♦ r.� 41�� S ` � ti r . r � �r� �`��]' V.�-a� _ 1`•" a�.... - '� 1 ` r 1' '.ice r �'� �! � r � r �y '\ �.r• r" r f `_ 1� J, I Y � \ �r '� yit''1 `''`�•ti� �� =Y3.•«r r� � f _ 1 t�$ �; r r�l� 4 � l` `���5� .r� f. f! _„ . •`^- 1�,. 7 i .`ti.'Frs - 5;, r "�r l r ✓� S (ii �. a IY.� Z\ k. .. Jr' � .» -� 111t �,✓ rr•'"� ;_", •L � .+,, r rr� `r-J f.ry � ,� { It t l's F�{•�"�` �� ...,.� 'S`--�•-'�`J•••�_ P, �. 1 f� "ti J S j a3-N ra•'`Y ��..+ 5.� -_ • �.� i _"t �i�k 5—•.Trt�r � 5� � t t 7fi1">,'�G} yLt {- �17;1�>✓t;1 <}IS. 4 .';'i - t �,h..O.t�r 1J14'r% cii?r {Z.tir a if I�iy�1-.,w. ]51 - "� I otit�{T f k.•N':t•r. ��a rirf'(, 5.�•" - r) f ` i '�- ^�t�� �. 4 c! i It,-4 KS� S! rr-... t � ''4,1J'z rS`'.._ a[ i r .x"'. F � � � � t \f r t �' ��_Je._._ i =��'S. s � `� .� S 1 �j v ��' .1••,f Yj I ♦ l i,s n ti r RileynL ] SC FY1. 4 ii3��J.t' �+ • -4 i'f(�r`�- R�� f`IL 4i�i rrv4 `5 �'! I F '• i� L1(I 5 t r Y! It Y a4zy i w ] ``sl'�zCy�/ Itii It4r`� r ~�2\1 'rrf 1i i,.��: t L� �t �~• fFfr6� '�3/-a5 "')• E a J a 4 rr a r �el.• I f .,,r •,. r '��y)--1 r� r!- j�IS �i�t 1 - 5 a rS5 5-.,p, _�•: i a=s✓' Jl r�ai s �`�1 �L i 1' � -_ �J •,•��. 53 l�lf T 'W' J ^ /,..' 4 -� 1 F11} �;I ` t "n i E •. + t ti �1� ssv j1I i ^ at _ y 5.. -"%_.. •r - J' � � I s �rr,� � + +i� ,�i I� �e1'�fl Yclf 1i'L-:� l A }fs � �l �`'�.-� �-K• r�-;?' Jr 1//•'I. i r s }S a ..i f 4 7 5 ,� /�1tf ✓ i\�5��t 3i aril^rj 7�-I}?�"? r r{sF.`4.;{``f /A.rf i r�F :.1'n r •i�ri ,: r"ta. 4i ISi 1 -. a r1• W'`vl- r i ([ « ^i. 7-s31 ( rr i_ ! a NM ''Y� I t+t • l 1^I S r�t= S, i ��151•�~ ,I.�� i I r " R � F.` f 'k� Y" i f / }{i { F } r V 1 j tY if "-: Il ))71`� / i tl i-e>` //� t �4r_' -L• )�r/ a ��//+-l� a� f � Cr� f _`)i ;lk; � A \ � r �`-•• � ��(;T ry Yj 4 J o- e, ."r i�� r .� ✓ J"�,.�'.r / at_,, ute { - "z J f -'-�./-,i ! \5 S ! S.. * .r / / f _ 1}. i' `a.�. .•f/! I f•li' J� r t.r � Y 5 � a �• ; �F f � - ' ! r` � i s_t i f ��+� r r } � _ r C - ..p "' !'X 4r. i_7�Lt l�.('� r"`! { fT %- !r / 1-•< i'. �'Y .l `,f: alZt � / /r/` 3'V1 E � r .r�,h }`� ff '.L • #1 �5� -� r {Le-� >'.-'�'/r 1 ,F'� � •s.�;\�\��.r � \'.� J,l . rl �'gT'1S 5.'� J�"^• � t '. 3.. `.I ! tJ s' _].•'�'xa <- -r"' .c. -t �.. 7 L-_l.Yt4r�'1 14 \v f.;� ra l\a��., �} 1`>"-1f4f-„`'✓ y.` i --'1 ��`+,,�\�tfr! �~iil�y�.f 1 j 1ctrlrr-�r• - S �ls f/ rrr` i c`�/ 1N1 a�cl..i f�- . J `• �' � h�--•,,/T '"1 i'"/ � J I �1�� S i ✓" .� `ti .j h a•.i �� . �t F r A ��1 Ste% a� '� 1 t T, Yli <�tif`� .�/�"� ', lj,f 1� t�..7 �` r r r1 r t/1 f+� r iIF`3 ��` �f rrf ,1 %- -�' •_r..i ,.:� r }. 1.)y ���"`--- � Zj. 'r /� ( �a� / 1r lL\ 7't , J •�%l S i 1 r i� n ♦ �� r �""y, ^s � � ��-.✓r`� y� -� t `v ` , ,w t~t l+�i �;, � � r ;- J: t t _ I ��� �K. ��r � ,{ !, i;� t.,� --��� �/ � r -L � �-,,� t a i S%: /�r��f r,��i74„!rit � �i �1� SA�.��� i 3' ���aL+ � •/ f z�r� ' � •r S 1 �!^ F.'i� ri f4u�'ti 'a�1t !� " ! l"i. -.'a .-� .. �_ _ .. Y Z .,..,•a. _% �'�^' . a- `1. 711:. � _ .r ._,w,. . NCG0 20 75 2 G.S. 'Ma feria ls, Inc. {-i Riley II Pit tt Lad UJde, 350,17' 59"• N Longitude: 790 9' 55" W County: Harnett Receiving Stream: OJT to Cypress Creel; Stream Class: WS-111 Map Scale 1.•24,00 Sub -basin: 03-06-14 (Cape Fear River Basin) Facility Location Lawyer, Mike From: Lawyer, Mike Sent: Friday, July 31, 2009 9:02 AM To: Lowther, E3rian Subject: RE: General Permit NCG02 NOI Hey Brian. I actually spoke with the engineer who submitted the NOI last week so I'm-somewhat'aware of the site conditions. As far as an O&M Plan, my understanding is that we can only require that if mine dewatering is to occur and have the potential to drain adjacent or onsite wetlands. If you don't need the site plans then send them my way. They would help me in future inspections. say go ahead and issue permit coverage. Thanks, Mike Michael Lawyer Environmental Specialist NCDENR-Division of Water Quality Surface Water Protection Section Fayetteville Regional Office Direct: (910) 433-3329 Main: (910) 433-3300 Fax: (910) 486-0707 e-mail: mike. lawyerCcDncden r.go (please note that my e-mail address has changed) *E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Lowther, Brian Sent: Friday, July 24, 2009 11:37 AM To: Lawyer, Mike Subject: General Permit NCG02 NOI Mike, We've received an NOI from GS Materials, Inc. for their mine Riley II Pit in Lemon Springs (Harnett County) for coverage of their Sand Pit covered under NCG02 (Material Mining SW permit). The site discharges stormwater into a LIT to Cypress Creek (WS-III). The NOI is attached. The site is near wetlands but the wetlands don't look to be on their site and they are not dewatering. Do you think the still might need to do an O&M plan? Also, I have one copy of large site plans. Do you want me to send them to your office? k Does the Fayetteville Regional Office have any concerns about issuing this facility a COC for this general permit, and are there any potential impacts to wetlands? If we don't receive any objections, we'll issue the COC in 30 days. Thanks, Brian Brian C. Lowther Environmental Engineer NCDENR I DWQ I Stonriwater Permitting Unit 1617 Mai] Service Center, Raleigh, NC 27699-1617 512 N. Salisbury St, Raleigh, NC 27604 Phone: (919) 807-6368 Email: brian.lowther(tDncdeiu•.�-,ov Website: httl):l/li2o.enr.state.11c.us/su/stormwater.11tml E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. 2 Lowther, Brian From: Lawyer, Mike Sent: Friday, July 31, 2009 9:02 AM To: Lowther, Brian Subject: RE: General Permit NCG02 NOI i Hey Brian. I actually spoke with the engineer who submitted the NOI last week so I'm somewhat aware of the site conditions. As far as an 0&M Plan, my understanding is that we can only require that if mine dewatering is to occur and have the potential to drain adjacent or onsite wetlands. If you don't need the site plans then send them my way. They would help me in future inspections. I say go ahead and issue permit coverage. Thanks, Mike Michael Lawyer Environmental Specialist NCDENR-Division of Water Quality Surface Water Protection Section Fayetteville Regional Office Direct: (910) 433-3329 Main: (910) 433-3300 Fax: (910) 486-0707 e-mail: mike.lawyer@ncdenr.gov (please note that my e-mail address has changed) *E-mail correspondence to and from this address may be subject to the North Carolina Public Records taw and may be disclosed to third parties. From: Lowther, Brian Sent: Friday, July 24, 2009 11:37 AM To: Lawyer, Mike Subject: General Permit NCG02 NOI Mike, We've received an NOI from GS Materials, Inc. for their mine Riley II Pit in Lemon Springs (Harnett County) for coverage of their Sand Pit covered under NCG02 (Material Mining SW permit). The site discharges stormwater into a UT to Cypress Creek (WS-III). The NOI is attached. The site is near wetlands but the wetlands don't look to be on their site and they are not dewatering. Do you think the still might need to do an 0&M plan? Also, I have one copy of large site plans. Do you want me to send them to your office? 1 a -a -8 Sri -16 -20 Shelter Creek Quarry Results for Monitoring Well 12: January 1, 2009 to June 1, 2009 oo oo 00`���0� oo� a`�o°j o`�\o��' o`�\�\o°' oo°' aoo o`�\ry6\09 0�� �o� o�o� 0�\�0\09' o�\ry�o°' oh�o1\d'' o`P14,oh\a��h\c� o4,^\o� Date r� Does the Fayetteville Regional Office have any concerns about issuing this facility a COC for this general permit, and are there any potential impacts to wetlands? If we don't receive any objections, we'll issue the COC in 30 days. Thanks, Brian Brian C. Lowther Environmental Engineer NCDENR I DWQ I Stormwater Permitting Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 512 N. Salisbury St, Raleigh, NC 27604 Phone: (919) 807-6368 Email: brian.lowther rr,ncdenr.gov Website: httt):Hh2o.enr.State.nc.us/su/Stor111water.h€tnl E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. ra CD �� J � L 3 i N f6 3 0 � 3 0 0 ,L^ V Wy�r� N 0 m - L M U r C in G Shelter Creek Quarry Results for Monitoring Well 13:May 12, 2007 to December 31, 2007 -2 -10 -14 31.1 -22 o ^�o� 141, ��o3 \' o�\o�\��\01 ���01 0�\0��0� 0�\,1\0� o�\��\o� o�\���o� o�,o\o, o��o\o� ��ao� �o� o�\,q�o� �\ry��o� ho\�\o� �o�o� �o\ry�\o� �,\o�pti ��\1�0� ��\ry��o� ^��Q� ^���C3 �o� Date Pender County Growing Season (50°/a Probability u1'28° or higher) March 17 to November 15 1 AD Division of Water Quality/ Surface Water Protection National Pollutant Discharge Elimination System NCG020000 NOTICE OF INTENT FOR AGENCY USL ONLY Dac Received YC4T ,1ltmlh Uay 0 eenirvaweurcuvers e Check # AI[wmnt .a Peniuw a. \SI�`RCd [(I �r National Pollutant Discharge Elimination System application for coverage under General Permit NCG020000: STORMWATFR P!SCHAR17-FS acenriated with aMiuities rtlaccifind sc SIC (Standard Industrial Classification) Code - 14XX Mineral Mining Industry (except as specified below) The following activities are also included: • Active or inactive mining operations (including barrow pits —except for NCDOT borrow pits) that discharge stormwater contaminated with or that has come in contact with, anv overburden, raw material, intermediate products, finished products, byproducts or waste products located on the site of such operations; • Stormwater from vehicle maintenance activities at mining operations; • Overtlow from facilities that recycle process wastewater; and/or • Mine dewatprinn (wastewater) The following activities are specifically excluded from coverage under this General Permit: • Stormwater discharges associated with peat mining, coal mining, and metal mining; • Stormwater discharges from mining operations which are intermixed on site with stormwater from asphalt operations and/or concrete operations; • Stormwater discharges associated with oil and gas extraction operations; and • Stormwater discharges associated with tourist gem mines NCDOT borrow pits are covered under NCS000150 The following discharges are covered by NPDES general Permit NCG520000 instead of NCG020000, • Point source discharges of stormwater and wastewater from in -stream sand mining operations (i.e., sand dredging or dipping operations) For new mining sites that require an authorization to construct (ATC) wastewater treatment facilities: This NOI is also an APPLICATION FOR an ATC for new wastewater treatment facilities. ATC requests must be submitted at least 90 days prior to construction'. For exist[ na miming sites that require an Authorization to Operate (ATO) wastewater treatment facilities: This NOI is also an APPLICATION FOR an ATO for wastewater treatment facilities in place. Construction, modification, or installation of any new treatment components at an existing site requires an ATC. (if the site is already covered by NCG020000, the ATC request may be submitted without an NOI). Some wastewater treatment facilities used to treat or recycle process wastewater (even if commingled with stormwater) at mining sites will require an ATC prior to constniction per 15A NCAC 2H .0138. Please see the NCG020000 General Permit for details about which treatment facilities require an ATC (summarized in Table 1 at the end of this form). For example, an ATC is required for treatment of mine dewatering discharge from clad} pits and non -closet! -loop wastewater recycle systems. The authorization to construct or continue to operate will be issued at the same time as the Certificate of Coverage (COC) for the NCG02 permil. Design of treatment facilities must comply with requirements of i')A NC:AC 2H -0138 & .0139. Page 1 0€ 7 IAs per 15A NCAG 2H .0106 2Unless treatment facilities are designed, constructed, and put into operation by employees internal to the company who are cluafied to perform such work for their respective companies in accordance wish General Statutes, 89C-25 (7), plans and specifications must be signed and sealed by a P.E. SWU-217-071408 Last revised'M4108 rur,r_nonnnn m-n-i Construction of wastewater treatment facilities subject to the AMATO requirements in the NCG02 permit at new or existing mining sites requires submission of three (3) sets of plans and specifications signed and sealed by a Professional Engineer (P.E.) or qualified staff2 along with this application. A copy of the design calculations should be included. Please see questions 18 & 19. Table 1: Wastewater Permit AMATO Requirements Mine Dewatering Yes No Quarries Sand Pits — — • Clay Pits • _ _ Any Dewatering with Chemical Treatment • -- Process Wastewater Sand/Gravel — Closed -Loop Recycle T • Other Recycle • — lvk_ For questions, please contact the DWQ Regional Office for your area. (Seepage 7) (Please print or type) 11 Mallinn address of owner/onerator faddress to which all nermit correspondence will be mailed). Name G Street Address City State Ale, ZIP Code _ ;t?Ug Telephone No.�G}�- �_ Fax: P_rn nil ArfrlrPSC 2) Location of facility producing discharge: Facility Name lJ4'e"y Facility Contact r!!, � Street Address _ „6 CC_ City State�✓��� ZIP Code Z County Telephone No. =��_22 Fax: _J!�M - AD9- Contact E-mail 3) Physical Location Information: Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). &tM!;` It ,S&L M OF xtf-ze nar PA�3T t'4►&' - wlixf LA - Mr aF 4) Latitude 3 Y-/- 0 Longitude . 7S- 34- }3 (degrees, minutes, seconds) 5) This NPDES Permit NOI Application applies to which of the following: XNew or Proposed Facility Date operation is to beg ❑ Existing ❑ New Permit not applicable - ATC request only. NPDES Permit Number Page 2 of 7 SWU-217-071408 Last revised 7114l08 NCG020000 N.O.I. 6) Standard Industrial Classification: Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code: 7) Provide a narrative description of the types of minerals mined at this facility: SrWA 6) Discharge Points: Number of discharge points (ditches, pipes, channels, etc. that convey discharges from the property): Stormwater:I Mine dewatering: Process Wastewater Overflow: Discharge points should be clearly marked on the submitted site plan. Please provide short narrative description of discharges: JzI%MW&j7A /S AFAICI �w .r� ► l _r .0 �� i A� L 9) Receiving waters: What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater and/or wastewater discharges end up in? ur�r 4~SS 69r62r. If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer)_ AA Receiving water classification (if known): _ 415—/7t Note: Discharge of process wastewater to receiving waters classified as WS-11 to WS-V or SA must be approved by the N.C. Dept. of Environmental Health. If DEH does not approve, coverage under NCG020000 cannot be granted. No new discharges of process wastewater are permitted in receiving waters classified as WS-1 or freshwater ORW. 10) Will mining operations require dewatering near wetlands or Impact any stream, groundwater, or wetlands? x No ❑ Yes if yes, please provide information about any 404!401 Certification permits. I Id—t • 4AlnHnnrin --f F.n r4 CAOI V nCI IMCATCr% nn •i.n n4nlnn +++n+ 1-- 1 the potential to drain wetlands or otherwise impact surface water or groundwater MUST develop and implement an Operation and Monitoring (O&M) Plan that has been approved by the Division. The O&M Plan should be submitted to the Regional Office and must be approved prior to operation. The plan shall include, but is not limited to: (1) Groundwater monitoring strategies to demonstrate the effect of pumping and to establish any pumping regime necessary to reduce impacts, and (2) Detailed ? plans to maintain surrounding nydrology ana respective monitoring to demonstrate compliance. i 11) Does this facility already have a valid Mining Permit from the Division of Land Resources (DLR)? ❑ No (If not, please indicate the status of the Mining Permit application: } XYes If vps. nlpase provide the Minina Permit number and inchide n conv with vour annliration: � �l Note: VIVO cannot issue a COC for the NC6020000 General Permit until a Mining Permit is issued or renewed by the Division of Land Resources (DLR). Page 3 of 7 SWU-217-071408 Last revised 7/14/08 NCG020000 N.O.I. 12) Will this mining operation precede development activities at this site? Y-No ❑ Yes 13) Does this facility have any other NPDES permits? X No F1 VOC If yes, list the permit numbers for all current NPDES permits for this facility: 14) Does this facility have any Non -Discharge permits (ex: recycle permits)? allo r_ 1 vac If yes, list the permit numbers for all current Non -Discharge permits for this facility: 15) Does this facility employ any best management practices for stormwater control? c❑N o yy Ives, please briefly describe: .SEA'it{g7trT_ BraS�R! 7f "- _ _CIS_ F_--ES_ ji� - 16) Does this facility have a Stormwater Pollution Prevention Plan? $No ❑ Yes If yes, when was it implemented? 17) Will vehicle maintenance activities occur at this facility? KNo ❑ Yes Wastewater Treatment Facilities: 18) Will mine dewatering discharges occur? (ATCIATO required for clay pits or dewatering with them, treatment) P4,No ❑ Yes 19) Will discharges of overflows from process wastewater treatment systems occur? (ATC or ATO required, unless sand/gravel mining or closed -loop recycle system) �INo ❑Yes f yes, answer the following questions on the wastewater treatment system: Please describe the type of process used to treat and/or recycle the process wastewater. Give design specifics (i.e. design volume, retention time, surface area, etc.). Existing treatment facilities should be described in detail, and design criteria or operational data should be provided (including calculations) to ensure that the facility can comply with requirements of the General Permit. [Use separate sheet(s)] Does this facility employ chemical additives to flocculate suspended solids? ❑ No ❑ Yes If yes, please state the name, manufacturer and the quantity of average daily usage of the chemical additive Note: Please see http://h2o.enr.state.nc.uslws/PAMS Iist.htm for a list of approved polyacrylamide (DAMS) products for use in North Carolina. Paae 4 of 7 SWU-217-071408 Last revised 7/14/013 NCG020000 N.O.I. Does this facility overflow only during rainfall events exceeding the 10-yr, 24-hr rainfall event? ❑ No ❑ Yes 20) Are wastewater treatment facilities (including recycle systems) planned in the 100-year flood plain? KNo ❑ Yes If so, include information to demonstrate protection from flooding- (Minimum design requirements for treatment works include protection from the 100-year flood, per 15A NCAC 2H .0219.) 21) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? 4 No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? 1�No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg, or more of hazardous waste generated per month) of hazardous waste? )114 Nn F-1 Vac d) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor: Vendor address: 991 1"artifirtatinn• Nnrth rarnlinn rpnpral StatiitP 141.215.E h ri1 nrnvirlac that - Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article: or who ialsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the 1Fnvirnnmantgl Mananemanll Commission imolamentinn this Ariirle �zhgil ha nuilty of a Glass 2 misrlwmaannr which may inrlurto a Finn nnI In exceed ten Thousand dollars IS10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I agree to abide by the following as a part of coverage under this General Permit: 1. I agree to abide by the approved Mining Permit for this mining activity. (A copy of the valid mining permit must be attached to this request. 2. 1 agree to not discharge any sanitary wastewater from this mining activity except under the provisions of another NPDES permit specifically issued therefore. 3. 1 agree that bulk storage of petroleum products and other chemicals shall have adequate protection so as to contain all spills on the site. 4. I agree that solid wastes will be disposed of in accordance with N.C. statutes and rules governing solid waste disposal. 5. 1 agree that maintenance activities for vehicles and heavy equipment will be performed so as to not result in contamination of the surface or ground waters. Pana 5 of 7 SWU-217.071408 Last revised 7/14108 NCG020000 N.O.I. I agree to abide by the provisions as listed above and recognize that the provisions are to be considered as enforceable requirements of the General Permit- { certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: K"fAT7Z4 ci<- Title: (Date Signed) Notice of Intent must be accompanied by a check or money order for $100.00 made payable to NCDENR. Final Checklist This application will be returned as incomplete unless all of the following items have been included, Check for $100 made payable to NCDENR B This completed application and all supporting documents -F:4- Copy of the valid approved mining permit (MP) for the facility or indication of MP application status -B' Copy of a county map or other general location map that shows the mining site and nearest major roads _[:i Copy of USGS topographic map showing the mining site and surrounding areas, or other map that clearly shows site location in relation to nearby streams, wetlands, and other waters, etc. -fe Copy of mining site plan with all wetlands clearly delineated ❑ If the mine is near wetlands, or may otherwise impact surface water or groundwater, contact the regional office about an O&M Plan (contact information on the next page). Please refer to this O&M Plan checklist: ✓ Site map with wetlands, ditches, well -placements, borrow areas, overburden storage, stormwater controls/BMPs, vehicle maintenance areas, settling basins, product process areas, and access roads. ✓ Well information (design, depths, maintenance) ✓ Physical monitoring for the wetlands areas Se<<Iing pond sizing information, H applicable ✓ Level spreader design, if applicable ✓ Details about dewatering method ✓ Description of measures to prevent erosion and flooding ❑ If an ATC or ATO is required, three (3) sets of plans, specifications, and design calculations, signed, sealed, and dated by a P.E. ATC and ATO requirements in NCG02000 are summarized in Table 1 on Page 2 of this NOI (see the permit text for more details). Plans shall show all pertinent design features, including the location of the outfall(s). If stormwater is flowing off -site, the plan must show that stoimwater will not be mixed with wastewater. Mail the entire package to-. Stormwater and General Permits Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of an NPDES permit. Page 6 of 7 SWU-217-071408 Last revised 7114108 NCG020000 N.O.I. Asheville Office ...... (828) 296-4500 .vefieviHe Office ... (910) 433-3300 -oresvitie Office ... (704) 663-1699 iaiciglfi Uflice ........ l`JId) /yt-4206 ............. r ....^p f �.1i21 glaF _F;IaR1 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office .........(919) 807-6300 Page 7 of 7 SWU-217-071408 Last revised 7114ru6 6.2 C 'i'eek- tlil-- Cr kiley rr7'f Az- 4A-J�7 (Hat,]/ 6A Mzw 2ocq-) I EXISTING BERM - o C THELMA ELIZABETH CNALMERS DB 662, PG 441 9546-93-7766.000ym _.. . . - z j a" s MINNIE LEE SMITH f D8 764, PG 974 9546-93-7255, 000 TRW N 01'27'00" 154'.79 bRIGINAL PERMfT BOUI 1222-62� ANNIE LEE CHALMERS HEIRS DB 452, PG 146 - 9546- 92- 4728.000 W0 . ' - BUFFER M) COD \, NWI WETLAND 84'43 QO :a... 739 WER ROWER 97 -. nnn "r 5 .. r WOO . sx. - LEGEND — - -� MINE BOUNDARY PROPERTY BOUNDARY EXISTING CONTOUR ' PROPOSED CONTOUR ADJOINING PROPERTY LINE !! NOTE WETL MOS a47A WAS TAKEN FROM USFWS WETLANDS M40PINO PROGRAM. e" GLE CARLETTA R 728, PG 755 -22-3325.000 Existing Conditions Max Disturbance: 20 Acres Required Sediment Storage: 0.83 Acre--ft. Water Storage Volume: 8.94 Acre--ft. 10—Year Runoff Volume: 7.70 Acre—ft. 25—Year Runoff Volume: 10.38 Acre—ft. 0-25 year outlet discharge: 13 CFS Future Conditions Max. Disturbance: 54.9 Acres Required Sediment Storage: 2.27 Acre—ft. Water Storage Volume: 7 acres excavated at averacie excavation base elevation of 369 ft. (38.5 acre--ft storage) 10—Year Runoff Volume: 15.2 Acre—ft. 25-- Year Runoff Volume: 19.8 Acre—ft. Q-25 year outlet discharge: NONE w t �o -- - - o RE-ESTABLISH 30' VEG. BUFFER AND RE -GRADE EXISTING BERM SECTION B SECTION C N 8f443'00" W i PROPOSED MODIFICATION I Stone Outlet Filter Section (NTS) Longitudinal Cross -Section 5' Upstream No. 57 Stone 1' Thi DownStream 1 L Lateral Cross -Section 19.0' LEGEND SLAL 3 ^L i ``�til111111ii!/*i`I o° �H CARP( MINE BOUNDARY ...•... ,149 PROPERTY `•�p�,, �pF�SSl041% �- BOUNDARY �, EXISTING CONTOUR SEAL PROPOSED CONTOUR =,• L-2822 ADJOINING PROPERTY LINEOr ���i1111111�►��,, NOTES THESE DRAWINGS WERE PREPARED FROM A PARTIAL SURVEY AND GPS TOPOGRAPHIC SURVEY. THESE MAPS WERE PREPARED FOR REVIEW, COMMENT, AND PERMITTING USES ONLY, AND ARE NOT FOR RECORDING OR LEGAL PURPOSES. w=i h uusiwr wntrol Stone NOTE: OUTLET DESIGN PREPARED AND DRAWN BY PATRICK SHILLINGTON, PE. E2S - ENGINEERING & ENWRONMENTAL SERVICES (SEE RELATED DESIGN DATA IN APPLICA7I0N) - - HWY 24127 (601 - � PUBL1C R/W) 4wWt..rv�r _ ,.vy,ti o1 BUFFER: 0' M 76'30'OD ^ W 512.34' f \ GRADE SLO ES 3: 1 OR FLATTER Q 1 1 � tirl��k ter Sh 0� I I KIRKPATRICK ASSOCIATES, LP G.S. MATERIALS, INC. HALL- RACKLEY MINE PERM! T 43 -16 Final Water Shed Area rrvvUV_U Stone Outlet Section BUFFER (See detail above) RE-ESTABLISH _30= VEG. BUFFER NWI WETLAND al —' AND'R�-GRADE EXISTING BERM i , , z a a Z 2 0 J a U R Z oW F J CC OW (a H —Z L aW oc � Wy a Cd I -- to O` co N O nJ U o —_ U � b Z I N Q- CQ O O J �_j Q) = w w cr] in N a J f w w 0 0 U) a� � O}�y� co 00 IX 1 I \ [ ..� O (• o ; a W L.1_ I REV. NDATE REVISIONS O. PROJECT TITLE G.S. MATERIALS, INC. PERMIT 43-11 HARNETT COUNTY, NC SCALE DEPARTMENT 1" = 150' DRAWN BY DATE STARTED SHEET No. JWT N4V. 2007 1 OF 3 CHECKED DRAWING NO, JWT APPROVED Sol JWT PROJECT NO, RILEY PIT 11 RENEWAL BY SEAL SEAL V��NIlCAROZ���4��i ag za a,ss ESS/a `. y by r stes 3]3R 2z7d, n ° SEAL <A a I ORIGINAL PERMIT MAP'� � � lratl � r�I �e = °� I_—�8�2 2NI -0 Su MINE IN MAP � �,"a�J' ESn / r L° ' �-. _ _ �>- /, '�.dtr�r_t .m�1adla �.1 i'•O'�xa.��.wra.r. !1rr',er.lw Jlls 1mzr�i1r135 ^. -3L3�2 !syao�r.i�f tc1fJ , aµr,' t 1 ,,D,.aT,sq1af 'tJ1Yz1" � 1 � �&1ti1=1T� , , ` - _ J1120 •ztlaa+iao �f�•�, n� su,tot°s 'I ,r 9 ° t , aChWMa� - % 'I�,•�w °w � •I1��urorsr.. €er.D1e�imn°!� * O+ RILEY }2 PIT MINING PERMIT W 43— I I � LEGEND MJ,1144 V25 NOTE: ck� 'mA`, t ' THESE MAPS WERE PREPARED FROM EXIS77NG NCDOT HIGHWAY i� MAPS, DELORME TOPOOUADS, HARNETT COUNTY GIS DATA FILES, zso7, AND AN EXISTING BOUNDARY MAP PROVIDED BY THE OWNER. < few} 1,1T i � nsa _ � ry '43aS � APt3 f � ' 22441 raurar trr 1 T +,em { 3247 -�'" ,t � T /1,1 � � V . 20R9 LIWE O F ` ! ° Ida ' im \ 7 f I NOTES: - OUT11 THS #WP Is AL#. OF LINE a i8-1sI O � 2) THS YAP WAS Z)Mw Pftu IXIST1M6 iIAPPii�. G , 4i 33 s1oPEs To BE aRmEO As 9HDrII ON TYPifJ,L cT1oN f r \-, msd _ - r 41 YDBE i%CAVATT31 TO DEPTH 6F SAbID BUT NAVE P63TIVE DRAfRAG6 " ^ ,Ioa �1 ym ^� 1 r .. - - r •``'� ;� 40,WATERIND FS lEEDED. e u; 61 SED. TRAPS AND SILT onuEs ORE "in To 118E IF NEEDED. O 11ae J � S i A n sEEDiEIO TO" 9E As KR ExISTrtii SPEca • s I `ti - �' R �" . £ - - - .r - - r f ET SrtxaE EMHIC! TD 9 HEED s NEEDED. - - ! _ ^� �— — —---— ♦� f �' — — -- .% �� 1 tf' V `1+ r ~ - L v �#° C Ij --�« INUMg GpA11Hd J 1Ft1 f L v, � + Q r, NOTE : MAP INCLUDES ONLY STATE MAINTAINED ROADS _ �•` , 1 +� k �.,�Q AWA 1 V ■. j oN IMPORTANT HGN-DYSTEM ROADS�ir LROADS SHOWN AS OF MAY 11. 200 k� _ `• R I `1 - !i s ` CaMniY 90rnddty 81I§400* AS We bawd ch N C D 0 T VICINITY MAP inTarmatten provkdatl by State artd irdemE 4 ` '•.,. � T � wgw mam• mad are sho— in Chair app---ate IL L �� T j & �` �u,sr1 aA'ot rI PIPE golonL SPILLWAY co— _ � 'ti 4 1 ! � $ rEiECC'ED rlLl lL.aCLb tM� Ei■, srM lllgA a -_. CMAC[EC AV: INfiEP riTH ti ♦� �� `♦ �1 F ,` f ` VECETA'rl� IT�]935 Q719 } f Q334S9 o014 U1 It ♦ , tjg� yd �9 733S7d - �33i56 o5'r ` 4 - ♦ ` 1 y `` n 102 CT Ar:4LOT itOr `r CVi T TIIE*fm r m17 won. ° ��k 7h W4 Ul - - - W W Q 7*AtLI210 OWMET -•. LP95M 9iJ7 z 1 m OIIADiA6E IaLEi Mlnt )rIr1NG IPJL it'ILL1rAl ,e• tY $ q00 •"'� � � ``� ti`,` �� '• \ � � � � r ar �uv[� 10 1Hta Pa,aT �� `*` k` ..�, .,` ^��♦ I% SEDIMENT BASIN I fJ N. T. S. 05.3; a>g a a c��Jr o5 [q2 0� f--_..� ti LENGTFI ' xT0' MIIDrtFE , 137r t __ 1 11 '� $ w L a ~ ` ♦ pEp'TT{ 3A' STORAGE - I I]4SJ0 Ex - - _ ;---� Lu r \` ' —,� `� \` `.` ``� •� WPUWAY,VIDTH • 35' KIRKPATRICK ASSOC E �% 099674 i s HALL—RACKLEY PiT IA]9' ,` a ,` �• �.� o.rk%8 0122 ■ _ r `S �5�'—= p� <r.:..�i�t1•� dTIWI�m.`. �L:�... r.......:5-.�.c...J CC cc T ,Ii'N our arrr, T 0 4 CyJ - SS l PEiMtliiEO AREA 2. 11HHE LEE SIIRH L - - - _ �1 ~'�� ♦ + uA ` ♦ T TEMP. DIET MM# AREA ;r,9;?5 �,1va 1 a' ` � - ♦ IF NEEDED DKTLL NTLL ':liar 'u';: I GRASS IS ESTABLISHED k — _ ♦ T \ , t EARTH BERM `� `� ti `. CATEGORY AFFECTED ACREAGEX. % rnarsfStarErr rasa ,.a° ' 1`� \4 EM. ` a7awr,.as at* QISI 91 �, r 1 - - �:r+a �;Aii ��5:.] I � /•� z � V' aArlEPliS � ANIVE LEE CHRILMEM' IEIM *3� ,, '� PaarAsamra �°Pn°r' �°a r I�> _ .sT '?a3? '�.�__ � 'J9fri'9g _ 4M1 Y+ u1 ^ ... W ,` J 0 � N TaNv I MIEN tlda sm .,,' _ `"`- U ! CV tATK raa+mra Alra . gcOn ... -, I ' U rts. wnaDESJ. - € k aRiM 0394 a2 ova& 13151 O W z 's' 31 U) 0 o _ antPyneamx _ RILEY 4 2 SAND MINE r3 4143 � J 1— J PART CiI ] . 2 W G.S. MATERIALS, INC. tars Are mwar i97 ik13i , Z E— U HARNETT CO. , NORTH CAR'OLINA '�' 3 W (o SEPT. 20, 2002 SCALE: I " = 100' SECTIN A A - - — - =3 L > m � IDd a 1ar7 2oa Zi sao DRAWN BY: JERRY W. THOMPSON P.E. 5049 HARNETT COUNTY PARCELS a W < � "P''TE� 6- PROPERTY OWNED BY KIRKPATWCK ASSOCIATES CC , J MINING PERMIT NO. 43- 1 1 cc E �R W W U) o 0 % "itu - w.�- - ' r . ' �� --'-'. � �- tea• L ..rid, � � _g ���•>.�, � •��,� .�_ �* _ � �' A� � ."� '`r ,, ,ter � "� , �_. �. tic„ ... _ ® ; _ __ 91r -_"°" � �''� i •A � � 'S .. �..,: : ,rs _.:_� w� :,.'. -. ".-.R__,-,,;..---'a-�= .^'" ��eV r" •'�at� ,..-::;i,.a :y..� �.r '°-�„^�'��r.v - "�t:°'�s'� "s iffa 'Art A v f _ �,� .. ,._ ..a:'r � .. e ,'� ram• r- r-'' ,:`' __ � `_., �. .., - '" . - �.a_'-"•�� Y _ - k" 7 '. 17 , r q f +:' _ r ' ,� - 4 .. �`iCw 't - ,�.�_.. w. �� - y���'n^^•'s'•xWrr _�_ , .a�__�"..r .0 y 2 �yp 3 ,- - ,> "xe. - • _...:-. v ., - r J' - yw:.iu'"`T .5 - . i iRtL pe ✓�`{' � - -Yc. .,. � .. -.,-x,C;.....i0�:. .. ""'•ate.. 1� ._.-.. � .3 r - . s t"ate" r�.+ 1A x .r t r ".. � _ .,. .. .... ` <, ;,.. .: r: i � tr � � '- _ s�:,,a�� ..,'k' -wM_ G::f$, s.•<. nr..%i1k't :r.6y,,- t.� ' Cab,-�-- - c a .3 � - • .a � "� a'i r-way ..� �` -.. - W.04ort�5 HARNETT COUNTY SOILS MAP 3—D TOPOQUAD '� � OTC �l aw ' '��^-Y- �R � 6�-+ �• P � I � _r�S l�_.:-�'.� i �.:- — `�'•��.f I� / I 'ti _ �• I f - f^-1` + 1 „} n'�-max♦t ' i �. - �y��.; � �� r� � �� f^-^�.�.� � ,Sl 4 i r r}� S . ■ i' 5 I E .f' . `} � ��r � t+ r i� � - f ! r� � ,Gf=fr '♦ � �� � I - ���'•-.-w _ .��_1.r 1 \ a)! 1 1 q r- .{ - • Ir Ws.n }1e S {ff 1t-1 i Ste- `r �� I t4 v§ �_1 f 1� ! E �•y Yr • l I ( k � i 7 i ti r i 5 5 t 'ti lr � � , � i y f i � f a 1 L 1 I .1 % �• ww.•+r NSF ( `fit rA i ■000 p t r— 11 1 f TsiaEdQcaurC�`1 + 19ATeiataeYtnar>�IMEOW Semi°1).trd;C:4';,w, RhJAs i4:1: 10.0 T,;SR M nwr -Ar„%4 TOPOQUAD �W5�o p co OQ O m W Q O LL REV. NO. DATE REVISIONS BY PROJECT TITLE G.S. MATERIALS, INC. PERMIT 43-11 HARNETT COUNTY, NC SCALE DEPARTMENT AS NOTED DRAWN BY DATE STARTED SHEET No. JWT NOV. 2007 2 OF 3 CHECKED DRAWING NO. JWT APPROVED Sw2 JWT PROJECT NO. RILEY it PIT RENEWAL 500 rROU 400 DATUM ELEV 360.00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 SECTION "A " m � Nl) M X!M M XC VA ON DE TH00 �"'1 N 'q- cp W (a ,"� O U] ^ .t tt ri �[l Of r7 N 6 6a) O «Z raj ap c�i N V? � a � 47 to � � � ah �h V to 47 to �r? cp cp n n 30' MIN, VEGETATED BUFFER TYPICAL VEGETATED DIVERSIQN BERM AROUND EXCAVATION AREA TOP !7f MINING AREA= 42©'�' AVE. WATER LEVEL 379' AVE, S�4AF, c'.I S�Oe� Z.1 BOTTOM OF POND = 372't AVE. CROSS SECTION OF EXCAVATION AREA NOT TO SCALE CONSTRUCTION SEQUENCE: 1. Obtain plan approval and permit renewal. 2. Inspect/upgrade existinggravel construction entrance, as needed. 3. Install outlet structure for sediment pond per design. 4. Repair and re -grade open -pit berm around excavation areas, using topsail to prepare top 6" of berm surfaces. 5. Grade existing mine site to drain entirely to excavation area and existing sediment pond. 6. Install lacking steel gate at mine entrance. 7. Prepare seedbeds, seed and mulch berms and completed mine areas in accordance with Vegetation Plan. $. Install 'OPEN PIT' warning signs around perimeter of mine. 9. Maintain/upgrade/reclaim buffers not meeting minimum criteria. 10. After excavation is completed, remove all temporary measures, regrade side slopes per Reclamation Plan, prepare seedbeds, and install vegetation in accordance with the Vegetation Plan. 11. When pond has stabilized, stock with hybrid bass qnd bream at rates recommended by a certified wildlife biologist. 400 DATUM ELEV 360,00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12-00 13+00 SECTION "B" a m - c� � EXISii G GROUND MA !MU E CA A Tf N EP �"� f\ � � � lC) 1\ n, n E\ d a? N co � r`i O �'S r\ oq �"•i rn eF d u� O) �i �i TMi � '� Ni Mi Ni *'i �'i sf � aO o N � O � ai d Mi � � o � QO d DO 0.) oCi oO fl0 DO �1D CO CO aD rn o) Q d N 34' MIN, VEGETATED BUFFER TEMPORARY SEEDING &MULCHING SPECIFICATIONS (Late Winter to Early Spring) Seeding mixture Species Rate (Iblacre) Rye (grain) 120 Annual lespedeza (Kobe in Piedmont and Coastal Plain, Korean in Mountains) 50 Omit annual lespedeza when duration of temporary cover is not t1� extend beyond June. Seeding dates [Mountains -Above 250t� fleet: Feb_ 15 - May 15 Below 25t){) feet: Feb. 1-May i Piedrrrcnt-Jan_ i - ivlaV i Coastal Plain -Dec. i -Apr. '15 Sail amendments Fallow recommendations of soil tee or apply 2,000 Iblacre ground agricultural limestone and 750 Iblacre 7il-9CI-1p fertilizer. Mulch Apply 4,D00IL�lacre straw. Anchor straw by tacking with asphalt, ��rjg, or a mulch anct#ariny tool- A disk with blades set nearly straight can be used as a mulch anchoring tool - Maintenance Refertilize if growth is not fully adequate Reseed, refertilize and mulch immediately following erosion or cutter damage. MINE CROSS-SECTIONSJu f GRAVEL CONSTRUCTION ENTRANCE DETAIL NOT TO SCALE S�N NtTES: 400 DATUM ELE� 340.00 3+00 4+00 5+00 S+DO 7+00 8+00 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+04 17+00 18+00 SECTION "C " as 9 GR y s i MAXIM EXCA AiiGN EPTh' i ,4ND � *- cv oa rn n tv cn ray � oa a� o r� r�7 o cv rn u7 rn � o 0 0 � co rn � o d- � <1' � d- � <Y d- d- � �n � �n � �n � � � cat cr c� � � o 0 d- rn a� rn rn oa ov ao ao as n n n ao �t d � d d• r7 M r7 t+] th r7 M M trl r�? r7 r' i 1. AGGREGATE SIZE -USE 2 TO 3 INCH WASHED STONE 2- DIMENSIONS OF GRAVEL PAD - THICKNESS: 6 INCHES MINIMUM WIDTH: 12 FOOT MINIMUM OR FULL WIDTH AT ALL POINTS OF THE VEHICULAR ENTRANCE AND EXIT AREA; WHICHEVER IS GREATER. LENGTH: 50 FEET MINIMUM 3. LOCATION --LOCATE CONSTRUCTION ENTRANCE AND EXIT TO LIMIT SEDIMENT FROM LEAVING THE SITE AND TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES. AVOID STEEP GRADES AND ENTRANCES AT CURVES. •` • � � �:,'-,ice' . PERMANENT SEEDING & MULCHING SPECIFICATIONS (NCDENR SEC MANUAL-TA3LE 6.1 1t) Seeding mixture Species' Rate Iblacre) Pensacola i3ahiagrass 50 5ericea lespedeza 30 gammon t3ennudagrass 10 German millet ,�] Seeding notes 1. Where a neat appearance is desired, omit seric4_ 2_ Use a common l3emzudagrass only on isalsed sites where it cannot become a pest. l3ennudagrass may be repaced with 5 Iblacre centipedegrass_ Seeding dates .Apr.1 -July 15 Soil amendments Apply time and fertilizer according to soil tests, or mealy 3,GfJ0 Iblacre ground agricultural limestone and 5001blacre 14-10]�3 fertilizer. Mulch Apply 4,00(1 Iblacre grain straw or equivalent cvveiaf another suitable mulch. Anchor by tacking with asphalt, racing, neirg; or by crimping with a mulch anchoring #not_ A disk with blades senearly straight can be used as a mulch anchoring toot. Maintenance Refertilize the fvtlowingApr. with � Iblacre ni#roger. repeat as growth requires. Inlay be mowed only once a year. Wherea neat appearance is desired, omit serieea and mow as often as neecd. "Refer to Appendix 8.02 for botanical names. 5' MIN. 3.0' Mir. 10% SETTLEMENT '-IiIT-3I1- CIE j -I -9� SLOPE TO MINE -�=1 EXCAVATION AREA CROSS SECTION OF OPEN PIT - DIVERSION BERM CONSTRUCTION SPECIFICATIONS FOR TEMP. BERM 1. REMOVE ALL TREES, BRUSH AND STUMPS FROM DIVERSION FOUNDATION_ 2. CONSTRUCT RIDGE TO FULL DIMENSIONS SHOWN- ALLOW 10 FOR SETTLING. 3. COMPACT RIDGE BY WHEELS GF CONSTRUCTION EQUIPMENT. 4. ENSURE THAT THE TOP OF TIC DIVERSION 15 ON DESIGN GRADE OR HIGHER AT ALL POINTS. 5. SEED AND MULCH IMMEDIATEL`' AVER CONSTRUCTION. SEE VEGETATION PLAN. ACREAGE DATA CATEGORY AFFECTED ACREAGE TAILINGS/SEDIMENT PONDS 1.5 STOCKPILES 2.0 WasTEPILES 2_ a PROCESSING AItEAlHAUL RD 1.0 MINI= ExeavATIDN 49.5 TOTAL AFFECTED ACRES 56.0 AREA WITHIN PERMIT BOUNDARY 59.1 MINE OPERATOR: G.S. MATERIALS, INC Po Box 1335 BURLINGTON, NC 27216 TEL: 919-499-9322 FAX: 919-499-2097 PROPERTY OWNER: KIRKPATRICK ASSOCIATES, LP Po Box 2570 BURLINGTON, NC 27216 TEL: 336-584-1745 Z a a z REV. I 22 DATE PROJECT TITLE REVISIONS t` OD CV O N � U � � i Z N �D` N O F-- J a) = W W V) m � N Q W W O O K7 Q N � � p co fr I O m O _ o w w F- G.S, MATERIALS, INC 'RILEY 11 PIT' HARNETT COUNTY, NC SCALE DEPARTMENT BY 1 ' = 100' DRAWN BY DATE STARTER SHEET No. JWT NOV 2007 3 OF 3 CHECKED DRAWING NO. JWT DET4 PPROVED JWT Ro.IECT NO. RILEY 11 PIT RENEWAL