Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG140426_COMPLETE FILE - HISTORICAL_20140718
STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /V Lo (0 DOC TYPE O"HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ o� lil �I 0 � I b YYYYMMDD 2,6 A NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Mr T E Chandler, Jr Chandler Concrete/Piedmont, Inc P O Box 131 Burlington, N C 27216 Dear Mr Chandler John E Skvarla, III Secretary July 18, 2014 DECEIVE® JUL 2 8 2014 CENTRAL FILES DWQIBOG Subject NPDES General Permit NCG 140000 Chandler Concrete/Piedmont, Inc Formerly VCNA Prestige Concrete Products, Inc Certificate of Coverage NCG 140426 Guilford County Division personnel received your request to revise your stormwater permit Certificate of Coverage to accurately reflect your new company and/or facility name Please find enclosed the revised Certificate of Coverage The terms and conditions contained in the General Permit remain unchanged and in full effect This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215 1 and the Memorandum of Agreement between North Carolina and the U S Environmental Protection Agency If you have any questions or need further information, please contact the Stormwater Permitting Program at (919) 707-9220 Sincerely, for Tracy E Davis, P E , CPM, Director Division of Energy, Mineral and Land Resources cc Winston-Salem Regional Office, M Gantt Stormwater Permitting Program Files Central Files Division of Energy, Mineral, and Land Resources Energy Section - Geological Survey Section • Land Quality Section 1612 Mad Service Center, Raleigh, North Carolina 27699 1612 - 919 707 92001 FAX 919-715 8801 512 North Salisbury Street Raleigh North Carolina 27604 • Internet http llportal ncdenr or, Iwq ebllrl An Equal Opportunity I Affirmative Action Employer — 50% Recycled 110% Post Consumer Paper STATE OF NORTEf CAROLINA DEPARTMENT OF ENVIRONMEN 1 AND NAI URA.L RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL, PERMIT NO, NCG140000 CERTIFICATE OF COVERAGE No NCG140426 srORMWAT> R DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215 1, other lawtul standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Fedeial Water Pollution Control Act, as amended, Chandler Concrete/Ptedmont, Inc is hereby authorized to discharge stormwater from a facility located at Chandler Concrete/Piedmont, Inc — Plant 117 3107-C South Elm -Eugene Street Greensboro Guilford County to receiving waters designated as an UT to South Buffalo Creek, a class WS-V, NSW water in the Cape bear River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, I1I, and IV of General Permit No NCG140000 as attached This certificate of coverage shall become effective July 15, 2014 This Certificate of Coverage shall remain in effect for the duration of the General Permit Signed this day July 15, 2014 for Tracy E Davis, P E , Director Division of Energy, Mineral, and Land Resources By the Authoi ity of the Environmental Management Commission A&e=VA NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Mr T E Chandler, Jr Chandler Concrete/Piedmont, Inc P O Box 131 Burlington, N C 27216 Dear Mr Chandler John E Skvarla, III Secretary July 18, 2014 Subject NPDES General Permit NCG140000 Chandler Concrete/Piedmont, Inc Formerly VCNA Prestige Concrete Products, Inc Certificate of Coverage NCG140419 Forsyth County Division personnel received your request to revise your stormwater permit Certificate of Coverage to accurately reflect your new company and/or facility name Please find enclosed the revised Certificate of Coverage The terns and conditions contained in the General Permit remain unchanged and in full effect This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215 1 and the Memorandum of Agreement between North Carolina and the U S Environmental Protection Agency If you have any questions or need further information, please contact the Stormwater Permitting Program at (919) 707-9220 Sincerely, f� for Tracy E Davis, P E , CPM, Director Division of Energy, Mineral and Land Resources cc Winston-Salem Regional Office, M Gantt Stormwater Pennrttmg Program Files Central Files Division of Energy, Mineral, and Land Resources Energy Section - Geological Survey Section • Land Quality Section 1612 Mail Service Center Raleigh North Carolina 27699 1612 - 919 707 92001 FAX 919 715-8801 512 North Salisbury Street Raleigh North Carolina 27604 • Internet hap /!portal ncdenr orglwebllrl An Equal Opportunity 1 Affirmative Action Employer — 50% Recycled 110% Post Consumer Paper S1 ATE OF NORT14 CAROLINA DEPARTMENT OF ENVIRONMEN r AND NA fURAL RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO NCG140000 CERTIFICATE OF COVERAGE No NCG140419 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215 1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the federal Water Pollution Control Act, as amended, Chandler Concrete/Piedmont, Inc —Plant 118 is hereby authorized to discharge stormwater from a facility located at Chandler Concrete/Piedmont, Inc —Plant 118 2865 Lowery Street Winston-Salem Forsyth County to receiving waters designated as an unnamed tributary to Salem Creek, a class C water in the Yadkin River Basin, in accordance with the effluent limitations, monitoiing requirements, and other conditions set forth in Parts 1, I1, 11I, and IV of General Permit No NCG140000 as attached This certificate of coverage shall become effective July 15, 2014 This Certificate of Coverage shall remain in effect for the duration of the General Permit Signed this day July 15, 2014 for Tracy E Davis, P E , Director Division of Energy, Mineral, and Land Resources By the Authonty of the Environmental Management Commission C.QNCR'E,TE- C(31VIPANXj June 27, 2014 Danny Smith Regional Supervisor -- Water Quality NC DENR 1628 Mall Service Center Raleigh, NC 27699 CERTIFIED MAIL By means of this letter I cerufy that Kenneth E Waegerle, Environmental, Health & Safety Manager, is the duly authorized representative for Chandler Concrete Company, Inc, and for Chandler Concrete/Piedmont, Inc He is responsible for the overall environmental operations and has the authority to sign documents and to shut down the operations should an emergency occur for any of our plants in North Carolina The plants in the Raleigh Region include, but not limited to, the following locations New Previous Permit Designation Address Designation Number Count 117 -- Elm Street 3107 S EIm-Eugene St VCNA Prestige Ready Mix NCG 140426 Guilford Greensboro, NC 27406 NC, Inc - Greensboro 118 — Winston 2965 Lowery St VCNA Prestige Ready Mix NCG 140419 Forsyth Winston Salem, NC 27 10 It NC, Inc - Winston Thank you for your attention to this matter Sincerely, f a A'1ndzq__ T E Chandler, Jr President Enclosures Forms — PERMIT NAME/OWNERSHIP CHANGE FORM —PLANT 117 — PERMIT NAME/OWNERSHIP CHANGE FORM -- PLANT 118 Asset Purchase Agreement r RECEIVED RE JUL 0 3 2014 DENR LAND QUALITY STORMWATER PERMITTING NC DENR Rale gh ,ag,onal Office POST OrricE Box 131 • BURLINC rON, NoR i H CAROLINA 27216-0131 TELEPHONE 336.226.1181 / FAx 336-570.0557 �; Division of Energy, Mineral & Land Resources AgY! Land Quality Section/Stormwater Permitting NCDENR National Pollutant Discharge Elimination System r+��a+we+*.nu NbwK r�samcra PERMIT NAMEIOWNERSHIP CHANGE FORM FOR AGENCY USE ONLY Date Received Year Month Day I Please enter the permit number For which the change is requested NPDES Permit (or) Certificate of Coverage N I C I S 10 1 1 1 1 1 1 1 N I C I G 1 4 0 4 2 6 11 Permit status prior to requested change a Permit issued to (company name) VCNA Prestige Concrete Products, Inc b Person legally responsible for permit Norm Wolff First Ml Last Chief Financial Officer Title 8529 South Park Circle Permit Holder Mailing Address Orlando FL 32819 City State Zip (407) 802-3540 _ (407)226-0359 Phone Fax c Facility name (discharge) VCNA Prestige Concrete Products, Inc - Greensboro d Facility address 3107-C South Elm -Eugene Street Address Greensboro NC 27406 City State Zip e Facility contact person Charles Tom Long (336 287-0415 First / M1 / Last Phone Hl Please provide the following for the requested change (revised permit) a Request for change is a result of ® Change in ownership of the facility ❑ Name change of the facility or owner If other please explain b Permit issued to (company name) Chandler Concrete/Piedmont, Inc c Person legally responsible for permit Kenneth E Waegerle First M [ Last Corporate Environmental, Health And Safetj Manager "I itle PO Box 131 Permit Holder Mailing Address Burlington NC_ 27216 City State Zip 336 226-1 181 ken was erle chandlerconcrete com Phone E-mail Address d Facility naive (discharge) Chandler Concrete/Piedmont, Inc - Plant 117 e Facility address _3107-C South Elm -Eugene Street Address Greensboro NC 27406 City Stati, Zip f Facility contact person Robert Mcdaniel First MI Last -(336)378-1002 plant I17rRchandlerconeretecom Phone 1 -mail Address IV Permit contact information (if different from the person legally responsible for the permit) Revised Jan 27 2014 NPDES PERMIT NAME/OWNERSHIP CHANGE FORM Page 2 of 2 Permit contact Kenneth E Waegerle First MI Last T �^ Corporate Environmental, Health And Safety Manager Title PO Box 131-� Mailing Address Burlington NC 272€6 City State Zip (336) 226-1181 ken waegerlepachandlerconcrete com Phone E-marl Address V Will the permitted facility continue to conduct the same industrial activities conducted prior to this ownership or name change9 ® Yes ❑ No (please explain) VI Required Items THIS APPLICATION WILL BE RETURNED UNPROCESSED IF ITEMS ARE INCOMPLETE OR MISSING ❑ This completed application is required for both name change and/or ownership change requests ❑ Legal documentation of the transfer of ownership (such as relevant pages of a contract deed, or a bill of sale) is required for an ownership change request Articles of incorporation are not sufficient for an ownership change The certifications below must be completed and signed by both the permit holder prior to the change, and the new applicant in the case of an ownership change request For a name change request, the signed Applicant's Certification is sufficient PER.MITTEE CERTIFICATION (Permit holder prior to ownership change) I, Charles Tom Long, attest that this application for a name/ownership change has been reviewed and is accurate and complete to the best of my knowledge I understand that if all required parts of this application are not completed and that if all required supporting information is not included, this application package will be returned as incomplete Signature if APPLICANT CERTIFICATION C jV7 LzO/ Date 1, Kenneth E Waggerle, attest that this application for a name/ownership change has been reviewed and is accurate and complete to the best of my knowledge I understand that if all required parts of this application are not completed and that if all required supporting information is not included, this application package will be r d as inc nm lete Signature Date PLEASE SEND THE COMPLETE APPLICATION PACKAGE TO Division of Energy, Mineral and Land Resources Stormwater Permitting Program 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Revised ,fan 27 2014 l ASSET PURCHASE AGREEMENT THIS AGREEMENT is entered into and made effective as of / , 2014 (the "Agreement Date") by and between VCNA PRESTIGE CONCR19TE PRODUCTS, ]INC ("Seller") a Delaware corporation, ("Seller"), and CHANDLER CONCRETEIPIEDMONT, INC a North Carolina corporation ("Buyer") Seller and Buyer are herein sometimes referred to as the "Parties„ RECITALS A Seller is engaged in the manufacture and sale of ready mixed concrete and concrete products and building supplies in Greensboro and Winston-Salem, North Carolina (tile "Business") Seller has agreed to sell to Buyer substantially all of the operating assets used by Seller in the conduct of the Business at the price and upon the terms and conditions described herein B Buyer has agreed to purchase the assets of Seller used in its operation of the Business at the price and upon the terms and conditions described herein NOW, THEREFORE, in consideration of the respective agreements and commitments set forth herein, and other good and valuable consideration, the receipt and sufficiency of which is hereby acknowledged by each of the parties, it is hereby agreed by and between Seiler and Buyer as follows 1 Basic Transaction The forgoing RECITALS, the Disclosure Schedule and all Exhibits are incorporated into and made part of this Agreement by this reference 1 1 Purchase and Sale of Assets On and subject to the terms and conditions of this Agreement, Seller agrees to sell, assign, convey, transfer and deliver to Buyer and Buyer agrees to purchase from Seller all of the assets used or useful in the conduct of the Business as presently conducted by Seller, other than the "Excluded Assets" as that term is defined herein, including without limitation the following described assets (all such assets to be purchased pursuant to this Agreement being herein sometimes referred to as the "Acquired Assets") (a) The real property used by Seller in the conduct of the Business located at and commonly known as 3107 C South Elm -Eugene Street, Greensboro, North Carolina consisting of approximately 9 4 acres and more particularly described on Exhibit 1 1(a-1) attached hereto, and the real property located at and commonly known as 2865 Lowery Street, Winston-Salem, North Carolina consisting of approximately 4 08 acres more particularly described on Exhibit 1 I (a-2) attached hereto (the two tracts being collectively herein sometimes 412931-000149f3915-�4 vl l IN WITNESS WHEREOF, the undersigned party has executed or caused to be executed this Asset Purchase Agreement as of the Agreement Date SELLER VCNA Prestige Concrete Products, Inc By not Name ��rR f " �t ri r Print Title _ T ,>C2s._ STATE OFFE6P494 NO O- OQr01rr%A, COUNTY OF 141ari"yt f— I certify that the following person personally appeared before me this day, acknowledging to me that [he/she] voluntarily signed the foregoing Asset Purchase Agreement for the purposes stated therein and in the capacity indicated ,7agS T . m u^ fib Date q _ f - ! L NotaryPublic- {Official Seal) _j q Print game of Notary LYDIA Y FLEEMAN NOTARY PUBLIC My commission expires 7`ad1& ALAMANCE CO, NC 01293I-U00149/391554 vl I I IN WITNESS WHEREOF, the undersigned party has executed or caused to be executed thus Asset Purchase Agreement as of the Agreement Date BUYER CHANDLER CONCRETE/PIEDMONT, INC By t-� f Print Name � 6-7 644^1 Ine JR. Print Title nef I d""J -- STATE OF NO H CAROLINA COUNTY OF knce I certify that the following person personally appeared before me this day, acknowledging to me that [he/she] voluntarily signed the foregoing Asset Purchase Agreement for the pmposes stated therein and in the capacity indicated (Official Seal) a FLEEMANY PUBLICCE CO , NC Notar,4Publ L lg V 41eeff-all Print Rame of Notary My commission expires L 7- s2o g 012931 000149/391554 A I North Carolina Pat McCrory Governor Mr Norm Wolff MCDENK Department of Environment and Natura Division of Water quality Charles Wakild, P E Director VCNA Prestige Concrete Products, Inc 8529 South Park Cir , Ste 320 Orlando, FL 32819 Dear Mr Wolff March 21, 2013 Resources John E Skvarla, III Secretary Subject General Permit No NCG140000 VCNA Prestige Ready Mix COC No NCG140426 Guilford County In accordance with your application for a discharge permit received on January 25, 2013, we are forwarding herewith the subject certificate of coverage (COC) to discharge under the subject state — NPDES general permit This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended) Please note that NCG140000 contains effluent limitations for process wastewater discharges (see Part IV, Section D) Wastewater discharges must meet the requirements of these effluent limitations An exceedence of any of these limitations is a violation of permit conditions Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water Quality The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other federal or local governmental permit that may be required Per the requirements of the Jordan Lake Nutrient Strategy Buffer Rule, all stormwater drainage to stream buffers, from portions of this site that have been constructed after August 11, 2009, must be discharged through a correctly designed level spreader or another device that meets diffuse flow requirements per 15A NCAC 2B 0267 Diffuse flow requirements are described in Chapter 8 of the North Carolina Stormwater BMP Manual, available at http /!portal nedenr orglweblwq/ws/su/bmp-manual Wetlrnds and Stormwater Branch 1617 Mail Service Center Ralei h North Carolina 276991617 Lom-on 512 N SahsLq St Raleigh North Carohr-i 276V Phoi 919 807 63001 IX 91 t' 07 6494 Inlem- www nwateatuphty otq An F= )pport my S Affirmaliue f i n mplo i None rthCarolzna Natilrallb, Mr Noi rr Wolff VCNA P, t�stige Concrete Products, Inc NCc 140126 March 21, 2013 Please note that permit requirements in Part II, Section A, numbers 1-5, and Part II, Section B, number 1 are no longer valid per NC Session Law 2011-394 However, note that Part 11, Section A, number 6, and Part II, Section B, numbers 2-10 are unaffected by this Session Law Those sections will remain in effect for the duration of this permit term Please be reminded that your facility must notify the appropriate DWQ Regional Office at least 72 hours in advance of operation of your wastewater treatment facility If you have any questions concerning this permit, please contact Robert Patterson at telephone number (919) 807-6375, or robert patterson@ncdenr gov Sincerely, pRIGINAL SIGNED M KEN PICKLE ,for Charles Wakild, f E cc Mike Mickey — Winston-Salem Regional Office Central Files Stormwater Permitting Unit Files enclosure Page 2 of 2 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO NCG140000 CERTIFICATE OF COVERAGE No NCG140426 STORMWATER & PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATIONI.,SYSTEM In compliance with the provision of North Carolina General Statute 143-215 1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, VCNA Prestige Concrete Products, Inc is hereby authorized to discharge stormwater and process wastewater from a facility located at VCNA Prestige Ready Mix 3107 R3 S Elm Eugene St Greensboro Guilford County to receiving waters designated as an UT to South Buffalo Creek, a class WS-V, NSW water In the Cape Fear River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1,11, 111,1V, V, and VI of General Permit No NCG140000 as attached This certificate of coverage shall become effective March 21, 2013 This Certificate of Coverage shall remain in effect for the duration of the General Permit Signed this clay March 21, 2013 ORIGINAL SIGNED B) KEN PICKLE for Charles Wakild, P E , Director Division of Water Quality By the Authority of the Environmental Management Commission HaSj$n IQ rui +vh Y- r NCG140000 N.0 I J w 4 3 �'�J P' ✓ r �� �J � r� F. r.r., P. (41 W F JAN 2 5 201,E NOTICE OF INTENT DW WATER MAUTY BO National Pollutant Discharge Elimination System application for coverage under eerrJ%*NgCA NCG140000 STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with activities classified as SIC (Standard Industrial Classification) Code 3273 and like activities - Ready Mixed Concrete This NOI may bean application to discharge process wastewater NCG140000 contains effluent limitations for process wastewater discharges Wastewater discharges must meet the requirements of these effluent limitations An exceedence of any of these limitations will result in a violation of the permit conditions For questions, please contact the DWO Central Office or Regional Office in your area (See page S) (Please print or type) 1) Mailing address of owner/operator official address to which all permit correspondence will be mailed (Please print or type all entries in this application form) Legal Owner Name VCNA Prestlge4Rea�E,t>+ >x'st•Z #-61DReT3a 140C. (Please attach the most recent Annual Report to the NC Secretary of State shoving the current legal name Altematively this permit can be given to an individual) Signee's Name (as signed for in question 29 below) Norm Wolff, CFO Street Address City Telephone No 8529 South Park Circle, Suite 320 Orlando State FL ZIP Code 32819 802-3540 Alternate Contact Name Alternate Contact Telephone (if different) 2) Location of facility producing discharge Facility Name Facility Contact Street Address City County Telephone No Email nmwolftaprestige-concrete corn Email (if different) VCNA Prestige Ready Mix_ C Tom Long _ 3107 R3 S Elm Eugene Street Greensboro State NC ZIP Code 27406 Guilford (336) 378-1002 Fax (336) 378-1064 3) Physical location information Please provide narrative directions to the facility (use street names, state road numbers, and distance and direction from a roadway intersection) Take interstate 40 to Greensboro Take South Elm Eugene St exit and proceed south about 0 8 miles Turn left onto Evander Drive to 3107 R3 S Elm Eugene Street (A copy of a county map or USGS quad sheet with facility clearly located on the map is a required part of this application ) 4) Latitude 36' 1' 32" Longitude 790 47' 17" (deg, min, sec) 5) This NPDES Permit Application applies to the following (check all that apply) ❑ New or Proposed Facility Date operation is to begin Existing Facility Permit # Not currently permitted SWU 229 06282011 Page 1 of 8 Last revised 6/28/11 6 Consultant's application information Notice of Intent and Stormwater Pollution Plan Preparation Consultant Miriam White, P E Consulting Firm ECS Carolinas, LLP Mailing Address 4811 Koger Boulevard City Greensboro State Phone Email North Carolina Zip Code 27407 (336) 362-5981 Fax (336) 856-7160 mwhite@ecslimited com Site Design Including Recycle System and Wet Detention Pond Consultant L Allan Hill, P E Consulting Firm Triad Design Group, PC Mailing Address 4807-C Koger Boulevard City Greensboro State North Carolina Zip Code 27407 Phone (336) 218-8282 _ Fax (336) 218-8010 Email ahill@tnad design2roup com 7 Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code 3 2 7 3 8 Provide a brief description of the types of industrial activities and products produced at this facility (Attach a site diagram showing the process areas present at this facility) The facility manufactures ready mix concrete by mixing cement, fly ash, water, aggregate materials, and additives or admixtures Storm water Discharge, Wastewater Treatment & Discharge and Permittigg Information 9 Discharge points / Receiving waters Number of discharge points (ditches, pipes, channels, etc ) that convey stormwater and/or wastewater from the property Stormwater-only Wastewater -only Wastewater Commingled with Stormwater one For new facilities Expected date of commencement of discharge What is the name of the body or bodies of water (creek, stream, river, lake, etc ) that the facility stormwater and/or wastewater discharges end South Buffalo Creek up in'? Receiving water class ification(s), if WS-V, NSW known If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e g City of Raleigh municipal storm N/A sewer) Will this facility discharge wastewater to SA (Shelifishing) waters? ❑ Yes �X No Page 2 of 8 Note Discharge of process wastewater to receiving waters classified as WS-11 to WS-V or SA must be approved by the N C Division of Water Resources, Public Water Supply Section If DWR does not approve, coverage under NCG140000 cannot be granted No new discharges of process wastewater are permitted in receiving waters classified as WS-1 or freshwater ORW 10 Each applicant shall provide the following information (attach additional sheets as necessary) • Two (2) site plans depicting the facility or site with numbered outfalls which indicate stormwater and wastewater outfalls The plans shall legibly show at a minimum, (existing or proposed) o Outline of drainage areas with topographical lines and features o Stormwater/wastewater treatment structures o Location of numbered stormwater/wastewater outfalls (corresponding to which drainage areas) o Runoff conveyance structures o Areas and acreage where materials are stored o Impervious area acreages o Location(s) of streams and/or wetlands the site is draining to, and any applicable buffers o Site property lines, North Arrow, and bar scale o If applicable, the 100-year fioodplain line o Acreage of each stormwater and wastewater topographical area o Each of the facilities' wastewater or stormwater source and discharge structures and each of its hazardous waste treatment, storage, or disposal facilities o Site location (insert) Site plans shall be 24"x 36" In size • Line drawing and description A line drawing of the water flow through the facility A pictorial description of the nature and amount of any sources of water and any collection and treatment measures • A narrative description and identification of each type of process, operation, or production area which contributes wastewater to the effluent for each outfal1, and a description of the treatment the wastewater receives (or will receive), including the ultimate disposal of any solid or fluid wastes other than by discharge Processes, operations, or production areas may be described in general terms (e g "ash silo") 11 Does the applicant have any unresolved Notice of Violations (NM)l []X No 0 Yes Wastewater 12 What types of wastewater does your facility generate or discharge's Type of Authorized Wastewater Generate Discharge Sent to WW Treatment System Vehicle and equipment cleaning (VE) X ❑ X Wetting of raw material stockpiles (RM) X X X Mixing drum cleaning (MD) X ❑ X Further explanation, if necessary 13 Will your facility spray -down or actively wet aggregate piles? No ❑X Yes Page 3 of 8 14 Does the facility use any of the following on site? Phosphorus -containing Detergents ❑X Non -Phosphorus -containing Detergents ❑ Brighteners ❑ Other Cleaning Agents ❑ Other 15 Are wastewater treatment facilities planned in the 100-year flood plain? No ❑X Yes l,✓4,4 1 S Youi2 FLoOb/A/G- co N t l (,4AIC y FG q ti ❑ Brighteners ❑ Other Cleaning Agents ❑ Other 16 Does your facility use or plan to use a recycle system, or recycle components in your treatment system? [] No ❑X Yes Recycle system will be used for vehicle and equipment cleaning and mixing drum cleaning wastewater Water from wetting raw material stockpiles will be treated in a detention pond with pH adjustment prior to -discharge If yes, what size storm event is the system designed to hold before overflowing2 (for example, 10-yr, 24-hr) 10 year, 24-hr rainfall event 17 Will your facility build a closed -loop recycle system that meets design requirements in 15A NCAC 02T f kit 1000 and hold your facilities' working volume' P El Yes'---' No Will your facility discharge wastewater to surface waters'2 [7X Yes F7 No it the facility's treatment system meets the design requirements of 15A NCACO2T 1000 (including holding the 25-year, 24-hour storm plus one foot of freeboard), holds the working volume of your site, and does not discharge wastewater to surface waters, you may not be required to obtain an NPDES permit for wastewater discharges If you believe this is the case, please contact DWO's Aquifer Protection Section land Application Unit Central Office Supervisor or staff (1636 Mail Service Center, Raleigh, NC 27699-1636) for more information on obtaining the necessary permits or approvals if you will discharge wastewater or stormwater to surface wasters, please continue to apply for a permit to discharge associated with ready -mixed concrete or like operations under NCG 140000 For further questions, please contact DWO's Stormwater Permitting Unit Staff 18 A wastewater treatment alternatives review is required by 15A NCAC 2H 0105 (c)(2) for any new or expanding water pollution control facility's discharge In North Carolina You may attach additional sheets a) What wastewaters were considered for this alternatives review9 7X VE XX RM M0 b) Connection to a Municipal or Regional Sewer Collection System i) Are there existing sewer lines within a one -mile radius? XD Yes ❑ No i See DWQ's Aquifer Protection Section Land Application Unit s Water Balance Calculation Policy for more information on QWQ OU s websde http /lporfal ncdenr orq/web/wnlaps/iau/policies for more information Page 4 of 8 (1) If Yes, will the wastewater treatment plant (WWTP) accept the wastewater? F-1 Yes FRI No (a) If No, please attach a letter documenting that the WWTP will not accept the wastewater _ A closed -low recycle system will be used for treatment of wastewater generated from vehicle and equipment- cleaning and mixing drum cleaning Wastewater generated from wetting raw material stockpiles will drain by overland flow to a detention pond The discharge of _ wastewater commingled with stormwater to the City of Greensboro POTW is prohibited (See attached letter from the City of Greensboro ) (b) If Yes, is it feasible to connect to the WWTP? Why or why not?* c) Closed -loop Recycle System (must meet design requirements of 15A NCAC 2T 1000) Are you already proposing a closed -loop recycle system (CLRS)? Vehicle and equipment cleaning and mixing drum wastewater will be treated in a recycle system that will only have a discharge during some storm events This discharge will flow to the wet detention pond, which incorporates a pH adjustment system (1) If Yes, contact DWQ's Aquifer Protection Section's Land Application Unit (2) If No, is this option technologically feasible (possible)? Why or why not7* A recycle system will be used for treatment of wastewater 9enerated from vehicle and equipment cleaning and mixing drum cleaning Wastewater generated from wetting raw material stockpiles will be treated with stormwater in a detention pond (3) If No, is it feasible to build a CLRS on your site? Why or why not?* Based on site topography it is not feasible to treat the wastewater generated from wetting_ raw material stockpiles in the recycle system (4) What is the feasibility of budding a CLRS compared to direct surface water discharge A recycle system will be used for treatment of wastewater generated from vehicle _ and equipment cleaning and mixing drum -cleaning Wastewater generated from wetting raw material stockpiles will be treated with stormwater in a detention pond d) Surface or Subsurface Disposal System (e g , spray irrigation) i) Is a surface or subsurface disposal technologically feasible (possible)? n Yes n No Why or Why not? _ The facility has insufficient acreage for installation of a surface of subsurface disposal system, Iu) Is a surface or subsurface disposal system feasible to implement?* ❑ Yes M No Why or Why not? The facility has insufficient acreage for installation of a surface of subsurface disposal system, ni) What is the feasibility of employing a subsurface or surface discharge as compared to a direct discharge to surface waters?* The facility has insufficient acreage for installation of a surface or subsurface disposal system, Page 5of8 e) Direct Discharge to Surface Waters Is discharge to surface waters the most environmentally sound alternative of all reasonably cost-effective options of the wastewaters being considered XD Yes ❑ No Direct discharge is proposed for wastewater generated from wetting raw material stockpiles and stormwater Wastewater generated from vehicle and equipment cleaning and mixing drum cleaning will be treated in a recycle system, with overflow during some storm events Recycle system overflow will discharge to the wet detention pond 0 If No, contact DWQ's Land Application Unit to determine permitting requirements f) If this review included all wastewater discharge types, would excluding some types (e g raw stockpile wetting) make any of the above non -discharge options feasible? 0 Yes [—] No You may be asked to provide further information to support your answers to these questions after the initial review Feasibility should take into account initial and recurring costs Stormwater 19) Does this facility employ any best management practices for Stormwater control? ❑ No M Yes If yes, please briefly describe Operational BMPs consisting of spill prevention and response procedures, good housekeeping program, preventative maintenance procedures, and inspections Structural BM_Ps consisting of limiting material storage in stormwater conveyance areas, diversion of runoff from outdoor material storage areas, enclosure of material storage areas (silos), dust collection ba house , seconds containment for oil storage, recycle system, and wet detention pond 20) Does this facility have a Stormwater Pollution Prevention Plan' F—] No [] Yes If yes, when was it implemented? To be implemented November2012 21) Are vehicle maintenance activities (VMA) occurring or planned at this facility's No Yes If yes, does your VMA area discharge into your wastewater treatment device? No 0 Yes Other/Permitting 22) Does this facility have a Division of Land Resources Erosion & Sedimentation Control (E&SC) Permit? No 0 Yes If yes, list the permit numbers for all current E&SC permits for this facility ication has been submitted 23) Is your facility subject to Phase iI Post -Construction Areal Yes No If yes, who is the permitting authority) The City of Greensboro is the permitting authority As this_project does not increase the built -upon area, the Gity of Greensboro has no requirements ^� Page 6 of 8 24) Is your facility located in one of the 20 Coastal Counties? El Yes X] No Is your facility adding more than 10,000 fe of built -upon area or CAMA Major Permit? ❑ Yes � No 25) Is your facility discharging wastewater (treated or untreated) such as water from wetting of aggregate piles, drum rinse -out, or vehicle and equipment cleaning to a stormwater BMP? ❑ No L—J Yes If yes, please attach your approval from the permitting authority to do so As this project does not Increase the built -upon area, the City of Greensboro has no requirements 26) Does this facility have any other NPDES permits> ❑X No D Yes If yes, list the permit numbers for all current NPDES permits for this facility 27) Does this facility have any Non -Discharge permits (ex recycle permits) X❑ No Yes 28) Hazardous Waste a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? XD No 0 Yes b) Is this facility a Small Quantity Generator (less than 1000 kg of hazardous waste generated per month) of hazardous waste? No = Yes c) Is this facility a Large Quantity Generator (1000 kg or more of hazardous waste generated per month) of hazardous waste? d) XE No 0 Yes Type(s) of waste How is material stored Where is material stored How many disposal shipments per year Name of transport 1 disposal vendor _ Vendor address Final Checklist This application will be returned as incomplete unless all of the following items have been included ❑ Check for $100 made payable to NCDENR '{ ❑ This completed application and all supporting documentation See Question 10 1 ❑ If an Erosion & Sedimentation Control (E&SC) Plan is required from Division of Land Resources (DLR) or local designee documentation verifying applicant has developed and submitted that Plan to the governing agency (required per 15A NCAC 02H 0138) f '— ❑ Two (2) site plans depicting the site plan with numbered outfalls which indicate stormwater and wastewater 1 outfails See Question 1'0 ❑ A county map or USGS quad sheet with location of facility clearly marked 29) Signatory Requirements (per 40 CFR 122 22) All applications reports or information subm itted to the Director shall be signed and certified a All notices of intent to be covered under this General Permit shall be signed as foliows Page 7of8 (1) For a corporaao, by a responsible corporate orricer For the pL rpose at this permit a t1sponsible corporate a7 cer means (a) a presILA anr secretary treasurer or vice president of the rorporaiion in charge of a principal business funcoon, or any other person who performs similar policy or decision making functions rcr she co,poratlon or (b) the maeager of one or more nianuractunng production or operating facilities employing more than 250 persons or having gross ennuaf sales er a pendrtures exceeding 25 mit[ion (in second quarter 1983 dollars) if authority to sign documenis has beer assigned or defegated �o the manager in accordance wth corporate procedures (2) For a partnership or sole propnetcrship by a general partner or the proprietor respectivehj or (3) For a municlpah6l, state, ffideral or ether p33blic agency by either a principal e,cecuti+re officer or ranking elected ofnclai Cerltificatuon North Carolina General Statute 143-215 6 Ill provides that Any person who knowngly makes any false statement, representation, or certification in any application record report plan or other document filed or required to be maintained under this Article or a rule Implementing this Article or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article or who falsifies tampers with or knowingly renders inaccurate any recording or monril device or method required o be operated or maintained under this AriTcle or rules of the [Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10000) I hereby request coverage under the referenced General Permit I understand that coverage under this permit v1111 constitute the permit reclu€rements for the discharges) and * enforceable in the same manner as an indl narmIT I certify that I am familiar with %he Information contained in this application and that to the best of my knowledge and relief such information is tale, complete, and accurate Printed Name of Person Signing 0--f' Title C d�f7 /Vill " (Slgrrature of Ap r nt) ?-/,,Ira (Date Signed) Notice of Untent must be accompanied by a check or money Dater for $100 00 made payable to MCDENR Mail the entire pac age to Stormvljaier Permitting Unit Division of Water Quality 1617 I viail Sennce Center Raleigh, North Carolina 27699-1617 Note The subml of this document doea "ot guarantee the Issuance of an NPUES 1permIt. For questfill please contact the DWO Regional Office for your ailea ti WO Ra;gionall mice Contact Infoli-ma${oil Asheville Office (828) 296-4500 Fayetteville Office (910) 433-3300 Nlooresville Office (704) 663-16,c,9 Raleigh Office (919) 791-4200 Washington Office (252) 946-648 , Wilmington Office (910) 796 7215 Winston-Salem (336) 771 5000 Central Office (919) 807-6300 Page 8 Oi 8 GENERAL DESCRIPTION PRESTIGE CONCRETE PRODUCTS GREENSBORO, NORTH CAROLINA VCNA Prestige Ready Mix operates a ready mix concrete production facility at 3107 R3 S Elm Eugene Street, Greensboro, North Carolina This facility is located on 5 43 acres Ready mixed concrete containing water, cement, fly ash, aggregates and supplementary additives is produced at this site Cement and fly ash are stored in silos These materials are transported from the delivery truck to the silos using a pneumatic system The silos are each vented to a baghouse The bags are periodically shaken and collected material is returned to the silos Aggregate, consisting of sand and three types of stone, are stored in four concrete bins These bins are three sided concrete structures The aggregate is delivered near the appropriate bin by a dump truck and a front ender loader is used to move the material into the bin As needed in the concrete production process, aggregate is loaded into the front end loader bucket and placed into a feeding hopper that discharges to an elevated conveyor belt that uses a radial stacker to feed one of four elevated bins Supplementary additives are stored in seven plastic aboveground storage tanks located in the chemical storage facility The tanks are filled from a commercial transport truck using fillports located within the storage facility The storage facility has a grated floor which has a discharge to a containment tank located under the floor A computerized control system is used to produce the required concrete mix When a concrete mix truck is ready to be filled it is parked under the weigh hopper A shroud surrounds the truck feeding hopper and emissions from the filling process are vented to the baghouse To produce truck -mixed concrete, all of the ingredients are charged to and mixed in the truck mixer The process begins with the discharge of approximately ninety -percent of the required water to the truck mixer The required aggregate materials are then fed from the batch plant to a scale followed by transport on a conveyor belt to the truck mixer Required amounts of cement and fly ash are weighted on a separate scale system and pneumatically conveyed to the truck mixer Liquid additives and the remaining water are then pumped to the truck mixer Prior to leaving the facility, the truck is driven to the wastewater recycle system The truck driver uses clean water from a tank located on the truck to clean the truck feeding hopper Wastewater generated from this cleaning procedure is discharged to the wastewater recycle system The facility has a closed loop recycle system that treats process wastewater generated from cleaning of external truck surfaces and mixing drum cleaning All cleaning will be conducted on an area constructed to discharge to the closed loop recycle system Wastewater flows from the cleaning pad to a three celled settling basin, with overflow from each cell flowing over a weir to the next cell The water from the last cell is recycled and used as mixing drum wastewater Based on storm volume, there may be overflow during storm events If the system overflows, overflow will flow by overland flow to the facility detention pond Gen -fal Description Prestige Concrete Products Greensboro, North Carolina Residuals collected ,n the closed loop recycle system and the detention pond are periodically removed to maintain settling capacity Residuals will be removed from each cell of the recycle system on a weekly bass and as needed from the detention pond Residuals will be placed on a concrete pad that drains to the closed loop recycle system Dry residuals will be sold The detention pond incorporates a pH adjustment system This system will produce an effluent with a pH within the acceptable range and pH adjustment will also produce precipitation of some component of the dissolved and suspended solids The facilint stores sand and aggregate material in four three sided uncovered concrete bins In the summer these materials are sprayed with water to reduce their temperature Water from spraying the sand and aggregate_piles will either evaporate or flow by overland flow to the wet detention pond The facility has one building in which the vehicle and equipment maintenance facility, the office, and the control room are located There are oil storage containers located within the vehicle and maintenance facility area and two additional aboveground diesel fuel tanks are located in the vicinity of the concrete plant Debris and trash are stored in one dumpster for subsequent off -site disposal 2 C'f7'l[�J j * 65 gal/hr — 6 hrs/day — only when temperature is greater than 80°F I SOURCE FIELD NOTES AND DRAWINGS +N ra FIGURE 7 WATER FLOW PRESTIGE CONCRETE PRODUCTS 3107 R3 SOUTH ELM EUGENE STREET GREENSBORO, NORTH CAROLINA NOT TO SCALE ECS PROJECT NO 09-21436 Fl olx �_ M of Greensboro Carolina Water Resources Department October 15, 2012 Prestige Concrete Products 3107 South Elm Eugene Street Greensboro, North Carolina 27406 c/o Miriam White ECS Carolinas LLP To Whom It May Concern This correspondence is in response to your letter of August 6, 2012 requesting a discharge determination for process wastewater generated at the Prestige Concrete Products facility located at 3107 South Elm Eugene Street in Greensboro NC The City of Greensboro Sewer Use Ordinance prohibits the routine discharge of storm water to the sanitary sewer system This prohibition includes storm water discharges from sheet run-off, discharges/overflows from storm water retention ponds and from other storm water impound devices G Therefore, the wastewater generated at the facility from wetting ra►k material stockpiles that ultimately flows to the site's stormwater retention pond is not acceptable for discharge to the Crty of Greensboro Sanitary Sewer System If you have questions or need additional information, please feel free to contact me at 336-433-7229 or by email at martie eroomegpgreensboro-pcRoov Sincerely, Martha Groome Laboratory and Industrial Waste Section Supervisor cc Frank Skee, Pretreatment Coordinator Sharon Miller, pretreatment Administrative Assistant PO Box 3136 Greensboro, NC 27402 3136 www menaboro ne eov - 336 373 CITY (2489) TTY # 333 6930 Patterson, Robert From Mickey Mike Sent Wednesday February 13 2013 10 08 AM To Patterson Robert Cc Basinger Corey Subject RE NCG140426 VCNA Prestige Ready Mix Guilford Co No concerns Please Issue Mike Mickey Mike Mickevl@NCDENR eov NC Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Phone (336) 771-4962 FAX (336) 771-4630 E mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties From Patterson, Robert Sent Wednesday, February 13, 2013 9 46 AM To Mickey, Mike Cc Basinger, Corey Subject NCG140426 - VCNA Prestige Ready Mix, Guilford Co Mike, Please see N01 attached I'm also forwarding you a set of the hardcopy plans We have received an application for coverage of an existing facility under NCG 14 from VCNA There will be significant site rework and grading from how is existing The facility drains to an UT to South Buffalo Creek (class WS-V, NSW) in Greensboro (Guilford County) They have vehicle maintenance, but no haz waste They also have all 3 types of ready mix ww, but only aggregate wetting will discharge directly to stormwater The other 2 types of ww will be directed to a recycle system that will overflow beyond a 10-yr storm As proposed, it will not meet the 2T rules, so it will be covered as a ww discharge under the NCG14 The ww recycle system Is also partially within the 100-yr flood zone Since it discharges to a water supply classified stream, I'll also have to be getting public water supply to sign -off on it Does the WSRO have any concerns about issuing this facility a COC for this general permit? Thanks Robert D Patterson, PE Environmental Engineer NCDENR I DWQ I Stormwater Permitting 1617 Mail Service Centtr Ralt.igh, NC 27699 1617 M iil 1 512 N Salisbury St 9th Floor R alcrgh NC 27604 1 m anon & Parct-Is (919) 807 6375 i'honr 1 (919) 807 6494 1 pax I Robert Patterson ancdenr gov Fm nl I har) //portal ncdenr ort?/web/wci/ws/su We b ott FA Before printing this email please consider your budget and the environment E mad correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to thud parties unless the content is exempt by statute or other regulation 4 del® NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Pat McCrory Charles Wakild, P E John E Skvarla, III Governor Director Secretary February 13, 2013 Memorandum To Regional Water Supply Supervisor, DWR Public Water Supply Section From Robert Patterson, DWQ Stormwater Permitting Unit Subject Review of the discharge location for the following VCNA Prestige Ready Mix 3107 R3 S Elm Eugene St Greensboro, NC 27406 Guilford County NCG 140426 Reported receiving water UT to South Buffalo Creek, 16-11-14-2a, WS-V, NSW Please indicate your agency's position on the facility listed above Attached is the staff report or other application information for this facility We cannot issue the permit without your concurrence Please return this form at your earliest convenience RESPONSE _x_ This agency has reviewed the draft permit and determined that the proposed discharge will not be sufficiently close to any existing or known proposed public water supply intake so as to create an adverse effect on water quality We concur with the issuance of this permit, provided the facility is operated and maintained properly, the stated effluent limits are met prior to discharge, and the discharge does not contravene the designated water quality standards Concurs with issuance of the above permit, provided the following conditions are met Opposes the issuance of the above permit, based on reasons stated below (or attached) Signed cc Stormwater Permitting Unit Files Attachments V J Mad Sermce Center Rafrgh North Carolina 27699 16 7 Location 512 N Salisbury St Paleigh North Carolina 27604 Pj one 919 807 6300 l FAX 4 , 9 807 6492 In rnr t www ncwaterquahly o Date 3-21-13 Nolle itliCalolma N E6,ialOpporturntylAlfirmata�c wiEmptcver Patterson, Robert From Patterson Robert Sent Wednesday February 13 2013 10 02 AM To Edwards Lisa Subject Review of proposed wastewater discharge to WS V Attachments NOI pdf Permit —Approval Memo_DWR doc Lisa, Please see attached memo and application Information for your review and comment If you need to see the plans, I'm sending Mike Mickey there in WSRO a hardcopy set today Please let me know if you have any questions Thanks We have received an application for coverage of an existing facility under NCG 14 from VCNA There will be significant site rework and grading from how is existing The facility drains to an UT to South Buffalo Creek (class WS-V, NSW) in Greensboro (Guilford County) They have vehicle maintenance, but no haz waste They also have all 3 types of ready mix ww, but only aggregate wetting will discharge directly to stormwater The other 2 types of ww will be directed to a recycle system that will overflow beyond a 10-yr storm As proposed, it will not meet the 2T closed -loop rules, so it will be covered as a ww discharge under the NCG14 The ww recycle system is also partially within the 100-yr flood zone Robert D Patterson, PE Fnvtronmental Engineer NCDDNR I DWQ I Stormwater Permitun�, 1617 Mail Service Center Raleigh NG 27699 1617 Mail 1 512 N Salisbury St 91h Floor Raleigh NC 27604 Loc aunn & P irc,c.ls (919) 807 6375 Phont 1 (919) 807 6494 Fax I Robert Patterso a,ncdenr gov 1,niail I http / /portal ncdenr org/web/Wg/ws/su Wcbsite bA Before printing this email please consider your budget and the environment E mad correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation Transmittal Letter Date January 23, 2013 To Stormwater Permitting Unit Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Project Prestige Concrete Products Greensboro, NC We Transmit ( x) herewith ( ) under separate cover i"+T` - J0N�— -J ta�rL 1013 AQMps �i Project No 12-0361D For Your ( x) approval ( ) review & comment ( ) use Copres Date Descrrpbon 2 December 6 2012 Notice of Intent to Discharge 2 December 6, 2012 Stormwater Pollution Prevention Plan 2 November 15, 2012 Design Plans 1 January 22 2013 E-mail Acknowledging Receipt of E&SC Plans 1 January 22,2013 TDG Check No 2238 ($100 00 Application Fee) Comments If you have any questions or need additional information, please contact me/ Copies File Submitted by L Allan Hill, P E Chief Civil Engineer 4807 C Koger Boulevard GrbL1h1Jlimts eNJ31=F94e761 AdnTn;P806-2t&SM"PT 336 218 8010 www triad designgroup com Allan Hill From Matt Johnson Sent Tuesday, January 22, 2013 9 53 AM To Allan Hill Subject FW Grading Permit Submittal for Prestige Concrete Allan- E-mail from Cass Below - Thanks Matt Johnson, P E Owl Engineer 4807 C Koger Boulevard Greensboro NC 27407 O 336 218 8282 F 336 218 8010 www triad designgrour com From Heaton, Cass [mailto Cass Heaton@greensboro-nc gov] Sent Tuesday, January 22, 2013 9 51 AM To Matt Johnson Subject Grading Permit Submittal for Prestige Concrete Matt This is to confirm that we have received a submittal of the sediment and erosion control plan for Prestige Concrete, located at 3103-R3 South Elm -Eugene St Greensboro NC 27406 Please let me know if you need any additional information Thanks, Cass A Heaton City of Greensboro Engineering & Inspections Department Development Services Division Erosion and Sediment Control cuss Keaton@ reensboro-nc ov Office (336) 333-6593 Mobile (336) 669-6764 Please note that email sent to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties r-1—� 9TLLP CARCr LANALS ECS CAROLINAS, LLP "Setting the Standard for Service" Geotechnical • Construction Materials • Environmental • Facilities NC Registered Engineering Firm F 1078 December 6, 2012 Stormwater Permitting Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Reference Notice of Intent National Pollutant Discharge Elimination System General Permit Number NCG140000 Prestige Concrete Products 3107 R3 S Elm Eugene Street, Greensboro, North Carolina ECS Project No 09-21436 To Whom It May Concern VCNA Prestige Ready Mix owns and operates a ready mix concrete facility located at 3107 R3 S Elm Eugene Street in Greensboro, North Carolina A Notice of Intent (NOI) for coverage under the National Pollutant Discharge Elimination System General Permit Number NCG140000 has been prepared for this facility (Attachment A) A ready mix concrete batch plant, office/maintenance building, material storage areas, closed -loop wastewater treatment system, and wet detention pond are located on the site The facility intends to demolish and reconstruct the existing closed -loop wastewater treatment system, regrade the site, reconstruct the wet detention pond, and remove underground storage tanks and ancillary equipment including pumps, piping and an oil/water separator A recycle system will be used for treatment of wastewater generated from vehicle and equipment cleaning and mixing drum cleaning Wastewater generated from wetting raw material stockpiles will be treated with stormwater prior to direct discharge Drawings prepared by Triad Design Group including the demolition plan, grading and drainage plan, site plan and details are attached as required by Item 10 of the NOI To complete item 10 of the NOI, a narrative description of facility operations and a line drawing of water flow are included as Attachment B Also included in Attachment B is a USGS map with the location of the facility marked As part of the wastewater treatment alternatives review, the City of Greensboro was contacted regarding acceptance of the commingled raw material stockpile wastewater and stormwater A determination from the City of Greensboro that they will not accept commingled stormwater and wastewater is included as Attachment C The Stormwater Pollution Prevention Plan (SPPP) prepared for this facility is included as Attachment D 4811 Koger Boulevard • Greensboro NC 27407 • T 336-856-7150 • F 336-856-7160 • www ecslimited corn ECS Carolinas LLP ECS Florida LLC ECS Mid -Atlantic LLC • ECS Southeast LLC ECS Texas LLP Prestige Concrete Products Notice of Intent ECS Project 09 21436 December 6, 2012 If there are questions regarding these documents, or a need for further information, please contact Miriam White, ECS Carolinas LLP at (336) 362-5981 or (336) 856-7150 Questions regarding the site design should be directed to Allan Hill of Triad Design Group, PC at (336) 218-8282 Respectfully submitted, Miriam S White, P E Senior Environmental Engineer Attachments A Notice of Intent B Narrative Description, Water Flow, and USGS Map C City of Greensboro Determination Letter D Stormwater Pollution Prevention Plan lldll')C--� i Michael Brame, PWS Environmental Principal NCG140000 N 01 NOTICE OF INTENT National Pollutant Discharge Elimination System application for coverage under General Permit NCG140000 STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with activities classified as SIC (Standard Industrial Classification) Code 3273 and like activities - Ready Mixed Concrete This NO[ may be an application to discharge process wastewater NCG140000 contains effluent limitations for process wastewater discharges Wastewater discharges must meet the requirements of these effluent limitations An exceedence of any of these limitations will result in a violation of the permit conditions For questions, please contact the DWO Central Office or Regional Office in your area (See page 6) (Please print or type) 1) Mailing address of owner/operator (official address to which all permit correspondence will be mailed) (Please print or type all entries in this application form) ^ OQ b Legal Owner Name VCNA Prestige Ready -Mix LowGrt0L7r2 Fe-0Dt�Ts, /A't (Please attach the most recent Annual Report to the NC Secretary of State showing the current legal name Alternatively this permit can be givers to air individual) Signee's Name (as signed for in question 29 below) Norm Wolff, CFO Street Address City Telephone No 8529 South Park Circle, Suite 320 Orlando State FL ZIP Code 32819 (407) 802-3540 Email nmwolff@prestige-concrete cam Alternate Contact Name Alternate Contact Telephone (if different) 2) Location of facility producing discharge Facility Name Facility Contact Street Address City County Telephone No Email (if different) VCNA Prestige Ready Mix C Tom Long 3107 R3 S Elm Eugene Street Greensboro State NC ZIP Code 27406 Guilford (336) 378-1002 Fax (336) 378-1064 3) Physical location information Please provide narrative directions to the facility (use street names, state road numbers, and distance and direction from a roadway intersection) Take interstate 40 to Greensboro Take South Elm Eugene St exit and proceed south about 0 8 miles Turn left onto Evander Drive to 3107 R3 S Elm Eugene Street (A copy of a county map or USGS quad sheet rnth facility clearly located on the map is a required part of this appiscation ) 4) Latitude 360 V 32" Longitude 790 47' 17" (deg, min, sec) 5) This NPDES Permit Application applies to the following (Check all that apply) ❑ New or Proposed Facility ❑X Existing Facility Date operation is to begin Permit # Not currently permitted Page 1 of 8 S WU 229 06282011 Last revised 6128/11 6 Consultant's application information Notice of Intent and Stormwater Pollution Plan Preparation Consultant Miriam White, P E Consulting Firm ECS Carolinas, LLP Mailing Address 4811 Koger Boulevard City Greensboro State North Carolina Zip Code Phone (336) 362-5981 Fax Email m wh ite @ ecs I i m ited cam 27407 (336)856-7160 Site Design Including Recycle System and Wet Detention Pond Consultant Consulting Firm Mailing Address City State Phone Email L Allan Hill, P E Triad Design Group, PC 4807-C Koger Boulevard Greensboro North Carolina Zip Code 27407 (336) 218-8282 Fax (336) 218-8010 ahill f toad-designgroup com 7 Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code 3 2 7 3 8 Provide a brief description of the types of industrial activities and products produced at this facility (Attach a site diagram showing the process areas present at this facility ) The facility manufactures ready mix concrete by mixing cement, fly ash, water, aggregate materials, and additives or admixtures Stormwater Discharge, Wastewater Treatment & Discharge and Permitting Information 9 Discharge points 1 Receiving waters Number of discharge points (ditches, pipes, channels, etc ) that convey stormwater and/or wastewater from the property Stormwater-only Wastewater -only Wastewater Commingled with Stormwater one For new facilities Expected date of commencement of discharge What is the name of the body or bodies of water (creek, stream, river, lake, etc ) that the facility stormwater and/or wastewater discharges end South Buffalo Creek up in? Receiving water classification(s), if WS-V, NSW known If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e g City of Raleigh municipal storm NIA sewer) Will this facility discharge wastewater to SA (Shellfishing) waters? ❑ Yes No Page 2 of 8 Note Discharge of process wastewater to receiving waters classified as WS-Il to WS-V or SA must be approved by the N C Division of Water Resources, Public Water Supply Section If DWR does not approve, coverage under NCG140000 cannot be granted No new discharges of process wastewater are permitted in receiving waters classified as WS-I or freshwater ORW 10 Each applicant shall provide the following information (attach additional sheets as necessary) • Two (2) site plans depicting the facility or site with numbered outtalls which indicate stormwater and wastewater outfalls The plans shall legibly show at a minimum, (existing or proposed) o Outline of drainage areas with topographical lines and features o Stormwater/wastewater treatment structures o Location of numbered stormwater/wastewater outfalls (corresponding to which drainage areas) o Runoff conveyance structures o Areas and acreage where materials are stored a Impervious area acreages o Location(s) of streams and/or wetlands the site is draining to, and any applicable buffers o Site property lines, North Arrow, and bar scale o If applicable, the 100-year floodplain line o Acreage of each stormwater and wastewater topographical area o Each of the facilities' wastewater or stormwater source and discharge structures and each of its hazardous waste treatment, storage, or disposal facilities o Site location (insert) Site plans shall be 24" z 36" in size • Line drawing and description A line drawing of the water flow through the facility A pictorial description of the nature and amount of any sources of water and any collection and treatment measures • A narrative description and identification of each type of process, operation, or production area which contributes wastewater to the effluent for each outfall, and a description of the treatment the wastewater receives (or will receive), including the ultimate disposal of any solid or fluid wastes other than by discharge Processes, operations, or production areas may be described in general terms (e g "ash silo") 11 Does the applicant have any unresolved Notice of Violations (NOVs)9 [X No ❑ Yes Wastewater 12 What types of wastewater does your facility generate or discharge? Type of Authorized Wastewater Generate Discharge Sent to WW Treatment System Vehicle and equipment cleaning (VE) X ❑ X Wetting of raw material stockpiles (RM) X X X Mixing drum cleaning (MD) X ❑ X Further explanation, if necessary 13 Will your facility spray -down or actively wet aggregate piled [] No Ox Yes Page 3 of 8 14 Does the facility use any of the following on site? ❑ Phosphorus -containing Detergents ❑X Non -Phosphorus -containing Detergents ❑ Brighteners ❑ Other Cleaning Agents ❑ Other 15 Are wastewater treatment facilities planned in the 100-year flood plain? No 0 Yes ❑ Brighteners ❑ Other Cleaning Agents ❑ Other 16 Does your facility use or plan to use a recycle system, or recycle components in your treatment system? No 0 Yes Recycle system will be used for vehicle and equipment cleaning and mixing drum cleaning wastewater Water from wetting raw material stockpiles will be treated in a detention pond with pH adjustment prior to discharge N yes, what size storm event is the system designed to hold before overflowing? (for example, 10-yr, 24-hr) 10 year, 24-hr rainfall event 17 Will your facrhty build a closed -loop recycle system that meets design requirements in 15A NCAC 02T + 1000 and hold your facilities' working volume' 9 1 ❑ Yes OX No Will your facility discharge wastewater to surface waters? QX Yes [] No If the facility's treatment system meets the design requirements of 15A NCACO2T 1000 (including holding the 25-year, 24-hour storm plus one foot of freeboard), holds the working volume of your site, and does not discharge wastewater to surface waters, you may not be required to obtain an NPDES permit for wastewater discharges if you believe this is the case, please contact DWO's Aquifer Protection Section Land Application Unit Central Office Supervisor or staff (1636 Marl Service Center, Raleigh, NC 27699-1636) for more information on obtaining the necessary permits or approvals if you will discharge wastewater or stormwater to surface waters, please continue to apply for a permit to discharge associated with ready -mixed concrete or like operations under NCG 140000 For further questions, please contact DWO's Stormwater Permitting Unit Staff 18 A wastewater treatment alternatives review is required by 15A NCAC 2H 0105 (c)(2) for any new or expanding water pollution control facility's discharge in North Carolina You may attach additional sheets a) What wastewaters were considered for this alternatives review? 0 VE XD RM F_X] MD b) Connection to a Municipal or Regional Sewer Collection System i) Are there existing sewer lines within a one -mile radius? XM Yes a No i See DWO s Aquifer Protection Section Land Application Unit s Water Balance Calculation Policy for more information on DWQ LAU s website http/Jo9r[al ncdenr org/webbyglaps/lau/policies for more information Page 4 of 8 (1) If Yes, will the wastewater treatment plant (WWTP) accept the wastewater? Yes XNo (a) If No, please attach a letter documenting that the WWTP will not accept the wastewater A closed -loop recycle system will be used for treatment of wastewater generated from vehicle and equipment cleaning and mixing drum cleaning Wastewater generated from wetting raw material stockpiles will drain by overland flow to a detention pond The discharge of wastewater commingled with stormwater to the City of Greensboro POTW is prohibited (See attached letter from the City of Greensboro ) ' (b) If Yes, is it feasible to connect to the WWTP? Why or why not?* c) Closed -loop Recycle System (must meet design requirements of 15A NCAC 2T 1 000) Are you already proposing a closed -loop recycle system (CLRS)? Vehicle and equipment cleaning and mixing drum wastewater will be treated in a recycle system that will only have a discharge during some storm events This discharge will flow to the wet detention pond, which incorporates a pH adjustment system (1) It Yes, contact DWO's Aquifer Protection Section's Land Application Unit (2) It No, is this option technologically feasible (possible)? Why or why riot?' A recycle system will be used for treatment of wastewater generated from vehicle and equipment cleaning and mixing drum cleaning Wastewater generated from wetting raw material stockpiles will be treated with stormwater in a detention pond (3) If No, is it feasible to build a CLRS on your site? Why or why not?* Based on site topography it is not feasible to treat the wastewater generated from wetting raw material stockpiles in the recycle system (4) What is the feasibility of building a CLRS compared to direct surface water discharge A recycle system will be used for treatment of wastewater generated from vehicle and equipment cleaning and mixing drum cleaning Wastewater generated from wetting raw_ material stockpiles will be treated with stormwater in a detention pond d) Surface or Subsurface Disposal System (e g , spray irrigation) i) Is a surface or subsurface disposal technologically feasible (possible)? n Yes I X I No Why or Why not? The facility has insufficient acreage for installation of a surface of subsurface disposal system, In) Is a surface or subsurface disposal system feasible to implement?' Yes [Z] No Why or Why not? _ The facility has insufficient acreage for installation of a_surface of subsurface disposal system, _ in) What is the feasibility of employing a subsurface or surface discharge as compared to a direct discharge to surface waters?* The facility has insufficient acreage for installation of a surface or subsurface disposal system, Page 5 of 8 e) Direct Discharge to Surface Waters Is discharge to surface waters the most environmentally sound alternative of all reasonably cost-effective options of the wastewaters being considered? 0 Yes No Direct discharge is proposed for wastewater generated from wetting raw material stockpiles and Stormwater Wastewater generated from vehicle and equipment cleaning and mixing drum cleaning will be treated in a recycle system, with overflow during some storm events Recycle system overflow will discharge to the wet detention pond i) If No, contact DWQ's Land Application Unit to determine permitting requirements f) If this review included all wastewater discharge types, would excluding some types (e g raw stockpile wetting) make any of the above non -discharge options feasible? X❑ Yes No ' You may be asked to provide further information to support your answers to these questions after the initial review Feasibility should take into account initial and recurring costs Stormwater 19) Does this facility employ any best management practices for Stormwater control? No IX Yes If yes, please briefly describe -Operational BMPs consisting of spill prevention and response procedures, good housekee m -program, preventative maintenance erocedures, and inspections Structural BMPs consisting of limiting material storage in stormwater conveyance areas, diversion of runoff from outdoor material storage areas, enclosure of material storage areas (silos), dust collection (baghouse), secondary containment for oil storage, recycle system, and wet detention pond 20) Does this facility have a Stormwater Pollution Prevention Plan? El No 0 Yes If yes, when was it implemented? To be implemented November 2012 21) Are vehicle maintenance activities (VMA) occurring or planned at this facility? No F_X] Yes If yes, does your VMA area discharge into your wastewater treatment device? ❑ No FX Yes Other/Permittrna 22) Does this facility have a Division of Land Resources Erosion & Sedimentation Control (E&SC) Permit? No a Yes It yes, list the permit numbers for all current E&SC permits for this facility *Application has been submitted 23) Is your facility subject to Phase II Post -Construction Area? M Yes F-] No If yes, who is the permitting authority? The City of Greensboro is the permitting authority_As this project does not increase the built -upon area, the City of Greensboro has no requirements Page 6 of 8 24) Is your facility located in one of the 20 Coastal Counties? 0 Yes fl No Is your facility adding more than 10,000 f? of built -upon area or CAMA Major Permit? Yes XD No 25) Is your facility discharging wastewater (treated or untreated) such as water from wetting of a regate piles, drum rinse -out, or vehicle and equipment cleaning to a stormwater BMP7 F-] No L.XJ Yes If yes, please attach your approval from the permitting authority to do so As this Project does not Increase the built -upon area, the City of Greensboro has no requirements 26) Does this facility have any other NPDES permits9 If yes, list the permit numbers for all current NPDES permits for this facility 27) Does this facility have any Non -Discharge permits (ex recycle permits)? 28) Hazardous Waste a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? XD No = Yes No Yes X❑ No 0 Yes b) Is this facility a Small Quantity Generator (less than 1000 kg of hazardous waste generated per month) of hazardous waste? X� No = Yes c) Is this facility a Large Quantity Generator (1000 kg or more of hazardous waste generated per month) of hazardous waste? d) No = Yes Type(s) of waste How is material stored Where is material stored How many disposal shipments per year Name of transport 1 disposal vendor Vendor address Final Checklist This application will be returned as incomplete unless all of the following items have been included ❑ Check for $100 made payable to NCDENR Wh ElThis completed application and all supporting documentation See Question 10 ❑ If an Erosion & Sedimentation Control (E&SC) Plan is required from Division of Land Resources (DLR) or local designee documentation verifying applicant has developed and submitted that Plan to the governing agency (required per 15A NCAC 02H 0138) —� ❑ Two (2) site plans depicting the site plan with numbered outfalls which indicate stormwater and wastewater I outfalls See Question 10 ❑ A county map or USGS quad sheet with location of facility clearly marked 29) Signatory Requirements (per 40 CFR 122 22) All applications reports or information submitted to the Director shall be signed and certified a All notices of intent to be covered under this General Permit shall be signed as follows Page 7of8 (1) For a corporation by a responsible corporate orircer For tine purpose of thz permit, a responsible corporate officer means (a) a president secretary treasurer or vice president of one corporation jr charge o` a pnncipal business function or any other parson �vho perfarr'ris similar policy or decision making functions for the corporation or (b) the manager of one or more manufacturing production or operating facilities employing more than 250 persons or having gross annual sales or expendrtures exceeding 25 million (in second quarter 1980 dollars) if authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures (2) For a partnership or sale proprietorship by a general partner or the proprietor respectively or (9) For a munrcrpalrty state federal nr other public agency by erther a principal executive officer or ranking elected official Certification Garth Carolina General Statute 143.215 6 B(l) provides that Any person who knowngly makes any false statement representation or certification in any application record report plan or other document filed or required to be maintained under this Article or a rule implementing this Article or who knowingly makes a false statement of a material fact in a rulemakmg proceeding or contested case under this Artrcla or who falsrfes, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental OAanagementj Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars {$l 0 000) 1 hereby request coverage under the referenced General Permit I understand that coverage under this permit mli constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual perm tt i certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information Is true, complete, and accurate Printed Name of Person Signing 4/0" f.✓0f, c Title r _ PO / Z/rIIl a . . . lv!i L11/6V (Signature of Ap r tit) (Dare signed) Notice of Intent must be acc©rnpanled by a check or honey order for $100 00 made payable to NCDENR Mail the entire package to Stormwater Permitting Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of an NPDES permit I_______ For questions, please contact the DWO Regional Office for your area UWg Fie tonal Office Contact Information Asheville Office (828) 296-4500 Fayetteville Office (910) 433-3300 Mooresville Office (704) 663-1699 Raleigh Office (919) 791-4200 Washington Office (252) 946-6481 ►Nilmington Office (910) 796-7215 Winston-Salem (336) 771-5000 Central O�fice (919) 807-6300 Page 8af8 GENERAL DESCRIPTION PRESTIGE CONCRETE PRODUCTS GREENSBORO, NORTH CAROLINA VCNA Prestige Ready Mix operates a ready mix concrete production facility at 3107 R3 S Elm Eugene Street, Greensboro, North Carolina This facility is located on 5 43 acres Ready mixed concrete containing water, cement, fly ash, aggregates and supplementary additives is produced at this site Cement and fly ash are stored in silos These materials are transported from the delivery truck to the silos using a pneumatic system The silos are each vented to a baghouse The bags are periodically shaken and collected material is returned to the silos Aggregate, consisting of sand and three types of stone, are stored in four concrete bins These bins are three sided concrete structures The aggregate is delivered near the appropriate bin by a dump truck and a front ender loader is used to move the material into the bin As needed in the concrete production process, aggregate is loaded into the front end loader bucket and placed into a feeding hopper that discharges to an elevated conveyor belt that uses a radial stacker to feed one of four elevated bins Supplementary additives are stored in seven plastic aboveground storage tanks located in the chemical storage facility The tanks are filled from a commercial transport truck using fillports located within the storage facility The storage facility has a grated floor which has a discharge to a containment tank located under the floor A computerized control system is used to produce the required concrete mix When a concrete mix truck is ready to be filled it is parked under the weigh hopper A shroud surrounds the truck feeding hopper and emissions from the filling process are vented to the baghouse To produce truck -mixed concrete, all of the ingredients are charged to and mixed in the truck mixer The process begins with the discharge of approximately ninety -percent of the required water to the truck mixer The required aggregate materials are then fed from the batch plant to a scale followed by transport on a conveyor belt to the truck mixer Required amounts of cement and fly ash are weighted on a separate scale system and pneumatically conveyed to the truck mixer Liquid additives and the remaining water are then pumped to the truck mixer Prior to leaving the facility, the truck is driven to the wastewater recycle system The truck driver uses clean water from a tank located on the truck to clean the truck feeding hopper Wastewater generated from this cleaning procedure is discharged to the wastewater recycle system The facility has a closed loop recycle system that treats process wastewater generated from cleaning of external truck surfaces and mixing drum cleaning All cleaning Voll be conducted in an area constructed to discharge to the closed loop recycle system Wastewater flows from the cleaning pad to a three celled settling basin, with overflow from each cell flowing over a weir to the next cell The water from the last cell is recycled and used as mixing drum washwater Based on storm volume, there may be overflow during storm events If the system overflows, overflow will flow by overland flow to the facility detention pond General Description Prestige Concrete Products Greensboro North Carolina Residuals collected in the closed loop recycle system and the detention pond are periodically removed to maintain settling capacity Residuals will be removed from each cell of the recycle system on a weekly basis and as needed from the detention pond Residuals will be placed on a concrete pad that drains to the closed loop recycle system Dry residuals will be sold The detention pond incorporates a pH adjustment system This system will produce an effluent with a pH within the acceptable range and pH adjustment will also produce precipitation of some component of the dissolved and suspended solids The facility stores sand and aggregate material in four three sided uncovered concrete bins In the summer these materials are sprayed with water to reduce their temperature Water from spraying the sand and aggregate piles will either evaporate or flow by overland flow to the wet detention pond The facility has one budding in which the vehicle and equipment maintenance facility, the office, and the control room are located There are oil storage containers located within the vehicle and maintenance facility area and two additional aboveground diesel fuel tanks are located in the vicinity of the concrete plant Debris and trash are stored in one dumpster for subsequent off -site disposal 2 � � ' • ' �' _L. �-' ',1r _� �i�� c � � � � ` "mow' � r•` _ - � Y - it � _ � .i -!(j: lrc`'S`���j�' tf1111•r 1_ �I t. �r +� .y'. , 5` C r. • a r _ •. SITE 423 IMPAIREDpp WATER s4 "---' 303(d) LIST °. • , 16-11-14-29 .�fi _ I _ 1 C r• a I :-`'�` of ' '' J ' ��� •• � `-' irk t }f �� 1 -i' J _ ]� ,0• r I• 'i `1 .yam ,ram , ym ir_ , , � ' r � �� •` Y •/'!`r /rj J, rr���i ,• �. � 1 I ... 9D ilk . �` �' - �`� r ' .- - • � Nei ti , � V . ..!°• .i �,i-� _' „ Fit ,� :/ •1 '. . -( '\�• w,r•'• .� ° -•� � -_- I\ •.+�• • h f h,r F ii - era _ FIGURE 1 SOURCE: SITE LOCATION MAP USGS TOPOGRAPHIC MAP PRESTIGE CONCRETE PRODUCTS GREENSBORO NORTH CAROLINA r� n 3107 R3 SOUTH ELM EUGENE STREET QUADRANGLE DATED 1951, REVISED 1994GREENSBORO, NORTH CAROLINA SCALE: 1" - 2000' C�G°QG3fl0[��G�LQ� ECS PROJECT NO, 09-21436A * 65 gallhr - 6 hrslday — Only when temperature 4s greater than 8011F SOURCE FIELD NOTES AND DRAWINGS FIGURE 2 WATER FLOW PRESTIGE CONCRETE PRODUCTS 3107 R3 SOUTH ELM EUGENE STREET GREENSBORO, NORTH CAROLINA NOT TO SCALE I(01/&MOLaKG°a&e ECS PROJECT NO 09-21436 ri 9l.mcityNor of Greensboro Carolina Water Resources Department October 15, 2012 Prestige Concrete Products 3107 South Elm Eugene Street Greensboro, North Carolina 27406 c/o Miriam White ECS Carolinas LLP To Whom It May Concern This correspondence Is in response to your letter of August 6, 2012 requesting a discharge determination for process wastewater generated at the Prestige Concrete Products facility located at 3107 South Elm Eugene Street in Greensboro NC The City of Greensboro Sewer Use Ordinance prohibits the routine discharge of storm water to the sanitary sewer system This prohibition includes storm water discharges from sheet run-off, discharges/overflows from storm water retention ponds and from other storm water impound devices Therefore, the wastewater generated at the facility from wetting ra%k material stockpiles that ultimately flows to the site's stormwater retention pond is not acceptable for discharge to the City of Greensboro Sanitary Sewer System If you have questions or need additional information, please feel free to contact me at 336-433-7229 or by email at martie 1groo_mei;reensboro-nc Qov Sincerely, Martha Groome Laboratory and Industrial Waste Section Supervisor cc Frank Skee, Pretreatment Coordinator Sharon Miller, Pretreatment Administrative Assistant PO Box 3136 Greensboro NC 27402 3136 wwwxreensboro nc aov - 336 378 CITY (2.489) TTY # 333 6930