Loading...
HomeMy WebLinkAboutNCG140358_MONITORING INFO_20140411STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO 0-11 IV U& )9U 3b DOCTYPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ y Oli YYYYMMDD NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Mr Johnie Alexander Concrete Supply Co, LLC P 0 Box 5247 Charlotte, NC 28299 Dear Mr Alexander John E Skvarla, III Secretary April 11, 2014 Subject NPDES General Permit NCG140000 Certificates of Coverage —See attached list Concrete Supply Co, LLC Formerly Concrete Supply Co Counties - Multiple Division personnel received your request to revise your stormwater permit Certificates of Coverage to accurately reflect your new company and/or facility name Please find enclosed the revised Certificates of Coverage for the 17 facilities that changed ownership from Concrete Supply Coto Concrete Supply Co, LLC The terms and conditions contained in the General Permit remain unchanged and in full effect These revised Certificates of Coverage are issued under the requirements of North Carolina General Statutes 143-215 1 and the Memorandum of Agreement between North Carolina and the U S Environmental Protection Agency If you have any questions or need further information, please contact the Stormwater Permitting Program at (919) 807-6300 Sincerely, ORIGINAL SIGNED W KEN PICKLE for Tracy E Davis, P E, CPM, Director Division of Energy, Mineral and Land Resources cc Mooresville RO, Z Khan, Winston-Salem RO, M Gantt (NCG140358) Stormwater Permitting Program Files Deborah Reese, DEMLR Budget Office — please update billing info Central Files Mecklenburg County DEP, Water Quality, 700 N Tryon Street, Charlotte, NC 28202 Division of Energy, Mineral, and Land Resources Energy Section • Geological Survey Section - Land Quality Section 1612 Mad Service Center, Raleigh, North Carolina 27699-1612 - 919-707-9200 I FAX 919 715 8801 512 North Salisbury Street Raleigh, North Carolina 27604 • Internet htto //portal ncdenr orglwebllrl An Equal Opportunity k Affirmative Action Employer — 50% Recycled k 10% Post Consumer Paper Permit NCG140358 SOC County Davie Region Winston Salem Compliance Inspection Report Effective 07/01/11 Expiration 06/30/16 Owner Concrete Supply Co Effective Expiration Facility Concrete Supply Company-Mocksville Plant 2151ndustnal Blvd Contact Person Steve Nailor Directions to Facility System Classifications Primary ORC Secondary ORC(s) On -Site Representative(s) Related Permits Inspection Date 10118/2011 Primary Inspector Sue White Secondary Inspector(s) Mocksville NC 27028 Title Phone 336 751 1187 Certification Phone Entry Time 08 00 AM Exit Time 08 30 AM Phone 336 771 5000 Reason for Inspection Routine Inspection Type Compliance Evaluation Permit Inspection Type Ready Mix Concrete Stormwater/Wastewater Discharge COC Facility Status ® Compliant ❑ Not Compliant Question Areas E Storm Water (See attachment summary) Page 1 Permit NCG140358 Owner Facility Concrete Supply Cc Inspection Date 10/18/2011 Inspection Type Compliance Evaluation Reason for Visit Routine Inspection Summary This site Is not being utilized by the company at this time Page 2 r Permit NCG140358 Owner Facility Concrete Supply Co Inspection Date 10118/2011 Inspection Type Compliance Evaluation Reason for Visit Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ Cl ❑ ❑ # Does the Plan include a General Location (USGS) map9 ■ ❑ ❑ ❑ # Does the Plan include a Narrative Description of Practices ? ■ Cl ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ®❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices9 ■ ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑ # Does the Plan include a BMP summary? ■ ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 ❑ ❑ ❑ # Does the facility provide and document Employee Training? ■ ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)) ■ ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ■ ❑ ❑ ❑ # Does the Plan include a Stormwater Facility inspection Program? ■ ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 Cl ❑ ❑ Comment Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi annually? ❑ ❑ ® ❑ Comment Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ ❑ © ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ® ❑ Comment Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ ❑ ❑ ❑ # Were all outfalls observed during the inspection? ®❑ ❑ ❑ # If the facility has representative outfall status is it properly documented by the Division? ❑ ❑ ® ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ ■ ❑ Comment Page 3 RECEIVED N C beat of ENR JUN 1 4 20i1 NC®ENR l Wlrston Salem North Carolina Department of Environment and Natural Resources egionalal 0� l Division of Water Quality Beverly Eaves Perdue Coleen H Sullins Dee Freeman Governor Director Secretary June 2, 2011 Johnie Alexander Concrete Supply Co - Concrete Supply Co-Mocksville 215 Industrial Dr Mocksville, NC 27028 Subject Rescission of NPDES Stormwater Permit Certificate of Coverage Number NCG 140238 Concrete Supply Co Concrete Supply Co-Mocksville Davie County Dear Permittee On 4/1/2011, the Division of Water Quality received your request to rescind your coverage under Certificate of Coverage Number NCG140238 In accordance with your request, Certificate of Coverage Number NCG140238 is rescinded effective immediately Operating a treatment facility, discharging wastewater or discharging specific types of stormwater to waters of the State without valid coverage under an NPDES permit will subject the responsible party to a civil penalty of up to $25,000 per day It is the intention of DWQ that enforcement proceedings will occur for persons that have voluntarily relinquished permit coverage when, in fact, continuing permit coverage was necessary If, in retrospect, you feel the site still requires permit coverage, you should notify this office, immediately Furthermore, if in the future you wish to again discharge to the State's surface waters, you must first apply for and receive a new NPDES permit If the facility is in the process of being sold, you will be performing a public service if you would inform the new or prospective owners of their potential need for NPDES permit coverage If you have questions about this matter, please contact Brian Lowther at (919) 807-6368, or the Water Quality staff in our Winston-Salem Regional Office at NPDES SW Sincerely, 4 t, , / P/t, e for Coleen H Sullins, Director cc Winston-Salem Regional Office Stormwater Permitting Unit DWQ Central Files - w/attachments Fran McPherson, DWQ Budget Office - please waive applicable fees Wetlands and Stormwater Branch One 1617 Mall Service Center Raleigh North Carolina 27699 1617 NorthCarollna Location 512 N Salisbury St Raleigh North Carolina 27604 Phone 919-807 63001 FAX 919 807 64941 Customer Service 1 877 623 6748 NR'tmallj,/ Internet www ncwaterquality org i/ An Equal Opportunity 1 Affirmative Acton Empbyer Mickey, Mike From Mickey, Mike Sent Wednesday April 27, 2011 4 34 PM To Lowther, Brian Cc Basinger, Corey Subject RE 4/27/11 Rescission Request List Attachments image001 prig Brian — Please rescind the two Concrete Supply permits in Davie County Concrete Supply had three NCG14 permits but only one facility Thanks, Mike 2 NCG140238 Concrete Supplg Co Concrete Supply Co Mocksvdle Active NPDES SW Winston Salen pave j11 NCG140334 I Concrete Supply Co Concrete Supply Co Dave I Expired INPOESSW I Winston Salen Davie Mike Mickey Mike Mickev('n NCDENR eov NC Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Phone (336) 771-4962 FAX (336) 771-4630 E mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties From Basinger, Corey Sent Wednesday, April 27, 2011 11 27 AM To Mickey, Mike, Thomas, Mike, Hudson, Gary, Boone, Ron, Smith, George, Carter, Jenifer, White, Sue Subject Fw 4/27/11 Rescission Request List Please review the attached list and respond back to Brian Cc me on your reaponse Thx Sent on the Sprint® Now Network from my BlackBerry© From "Lowther, Brian" <brian lowther@cdenr gov> Date Wed, 27 Apr 2011 11 09 55 -0400 To Lowther, Brian<brian lowther@ncdenr gov>, Hodge, Al<al hodge@ncdenr gov>, Shiver, Rick<rick shiver@ncdenr gov>, Henson,Belinda<belmda henson@ncdenr gov>, Smith, Danny<danny smith a ncdenr gov>, Krebs, Rob<rob krebs@ncdenr gov>, Edward s,Ro ger<roge r edwards@ncdenr gov>, Basinger, Corey<corey basinger@ncdenr gov> Cc Scott, Georgette<georgette Scott@cdenr gov>, Allocco Marcia<marcia allocco@ncdenr gov>, Willis, Linda<linda willis@ncdenr gov>, Bou-ghazale Samar<samar bou-ghazale@ncdenr gov>, Bennett, Bradley<bradley bennett@ncdenr gov> Subject 4/27/11 Rescission Request List All, Attached is the updated pending rescissions list if you need more information or would like me to scan and send you a copy of any specific rescission request please let me know Please try and respond within 30 days (May 27) Thanks Brian Brian C Lowther Environmental Engineer NCDENR I DWQ I Stormwater Permitting Unit 1617 Mail Service Center Raleigh NC 27699-1617 512 N Salisbury St, Raleigh, NC 27604 Phone (919) 807-6368 Email Brian lowtheronedenr ov Website http //portal nedenr orglweblwglwslsu E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties Permit Rescissions Permit Number NCG020519 NCG030575 NGG050332 NCG060032 NCGO60077 NCGO60078 NCGO80356 NCG100035 NCG140102 NCG140238 NCG140334 NCG180105 NCG180130 N CG i 80240 N CG 190074 NCG200447 NCG210167 NCGNE0640 NCGNE06B2 Record Number Rescission Status Owner Name Facility Name Permit Status Program Category Region County Requested Cow pasture Mine Cow Pasture !Nine Expired NPDES SW Fayetteville Sampson 01/04/11 Pgt Industries PGT Industries Active NPDES SW Mooresv+tie Rowan 01131N1 Georgia Pacific Consumer Products LP Alpha Plastics Division Active NPDES SW Fayetteville Richmond 02/14/11 ICI Americas Inc ICI Amencas Inc -Mecklenburg Expired NPDES SW Mooresville Mecklenburg 01/12111 R J Reynolds Tobacco Company Brook Cove facility Active NPDES SW Winston Salem Stokes 03/28/11 R J Reynolds Tobacco Company North Main Street fac:4ty Active NPDES SW Winston Salem Forsyth 03l26111 Fedex National Lill Inc Fed Ex National LTL Inc Charlotte Active NPDES SW Mooresville Mecklenburg 02/18/11 Aberdeen Used Cars & Parts Aberdeen Used Cars & Parts Active NPDES SW Fayetteville Hoke Will Southern concrete Materials Inc Southern Concrete Mat Active NPDES SW Mooresville Mecklenburg 02/18/11 Mecklen b Concrete Supply Co Concrete Supply Co-Mocksville Active NPDES SW Winston Salem Davie 04/01/11 Concrete Supply Cc Concrete Supply Co -Davie Expired NPDES SW Winston Salem Davie 04101/11 Baker Furniture Company Baker Furniture Company Expired NPDES SW Asheville Burke 12117/10 Watauga Wood Products Inc Watauga Wood Products Expired NPDES SW Winston Salem Watauga 03/14/11 Incorporated David Stout of Furniture Brands Thomasville Plant 9 Active NPDES SW Mooresville Catawba 03/14/11 Marinemax East Inc MarineMax Wrightswile Beach Active NPDES SW Wilmington New Hanover 0411all 1 Asheville Metal Recycling Asheville Metal Recycling Active NPDES SW Asheville Buncombe 01/12/11 Georgia Pacific Wood Products LLC Georgia Pacific Wood Active NPDES SW Washington Hertford 01106/11 Products LLC Inspire Pharmaceuticals Inc Inspire Pharmaceuticals Inc Active NPDES SW Raleigh Durham 03/18/11 Fedex National Ltl Inc Fedex National LTL Inc Ash Active NPDES SW Asheville Buncombe 02/18/11 19 FOR AGFNC,Y USE ONLY Date Received_ A,*' ,� Division of W.itcr ()L%.t 3,5 , S1i� Mace t�V, tit % � ou�tr, — ° Ye�r, Nlc nth D� � Natrun�l Pollutant Druhtrge Elrtn►n uron Sysierii t ' t1 c aGLt MCDEN,.I F 11 qT 1R�) I1 �PIf,Tlrv)rTC1F R �C1SS'ON REQUEST FORA APR 0 # 701 Wlrs, 1 rNty- Please R out and return this form 1` you no longer (teen to mRimain} j� u-, 11PDCS stormwdter permit 1) Enter the permit number to which this request applies Individual Permit tor) ` Cnrtiflcate of Coverage 2) Owr, sr/Facility information ' final corresponderr. will L: mar od to the oc.'ress notca below Own(r/Facility Name � v11 C,(c �lJ; ��_ r ��� Facility Contact �U h n r c- Street Address r, I I I f City _ _�� __ �Ctl�Cft7-vr�1�,_ _ .._� _state-_ AJ(- — ZIP Code-----.�) 7 0 _ County _-f--mail Address-- Sc)4,,,e (Telephone No �-7—— c' �� 7^��, s'�_�..-� � Fax 1� -33=l-emsES�� i 13� pt , o 1, 3 .I(ir jt t. r 6J t G, tic ( ^1 i f s t r 3) ReaEon, for rescission request( his is rc tc d information Af-taC'= _--parate shy„' ill necessary) Facility closed or is closing on 1511 industrial activities -a c ceaGed suc i that no o scharcgc,s of tormwater are contarninated by exposure to irioustrial act vilioc _ iatorials' 1 [] Facility sold to P r rr r , ,a � on it Ir,thg taciltiy,will,cuntinue operations under the new owne- it may tie more appropriate to request an ownership char ge to ret.aut to permit to tiro new owner Other 1 -v (- LIU 4) Certification i I, as an authorized representative, hereby request rescission,of coverage under the NPDES Stormwater Permit for the subject facility I am familiar with the information contained in this request and'tolhe best of my knowledge and belie-, such infi rmation is true, complete and accurate ��Nrilr �f�r'r1G, f �!...,... _-.. �...— ,Y1✓ltuil �C�l�/ �L�t`'yrti Jam✓ + Print or type name of person sigmrir,+ abc,+e (rile Please return this completed ret, i--ston -equc<t forrn,ro i ► , I A W NPf)FS Pp-- t Covx r igr Rescission Sto"Ihatr-r -erraumn„ mt- L61,' Mz(='zt rvice, Center €tateigl,, Caro€ ,,a 27(109-1617 t, J�� ! �" .''' `t�'t.� e • �+r l L 01 , 1 1 ( 0 0; l id t �11 �},}r �tii'��►�'� r` .-. +, tl{�d ifA ��df�lf AY r ..__ __ _-- _ rntiia ) i' ►7 is. 7 ev) wi}.. i 1 `4i I^i{� „s 1 1 t I r ` b to _ ��' t ► 1 t �!`l1p i i 7li i i 1} 1 l � 4 -. _ — .. � +� ..... w•..w-..w �. l.� ....r _ a�— ..�_.—.�.....�-.�sr �.. � -�+.� .�.._.��>> M1�l }.�.. i )�_ I� `I` � Y I ff s I t? i ' .► c G t ?, f-r ''v{:L� 1���.}I it " ii ! S � ►i37r ii ti f 1! 4 r AF - 0 4 Division of Water Quality / Surface Water Proterti m ��"lh IL M APN National i'ollutat + ^p ' ' DisLliarge lritminat on 5y,r.,. � FOR AGENCY USE ONLY Date Received Year Month Da rim -,�"'• -� � ,� RESCISSION REQUEST FORM - -- ---- ------------ APR 0 1 2011 T I Winston balm* Please fill out and return this form if you no longer need to maintain your NPDES stormwater permit Regional Office 1) Enter the permit number to which this request applies Individual Permit (or) Certificate of Coverage � N CIS -�N i C_jG I 2) Owner/Facility Information ' Final correspondence will be marled to the address noted below /7 Owner/Facility Name CUk) Cr'll S"Of9111 CCU " Facility Contact 13:U 4 V1 (< A/{n L' n(�/ev-.-- Street Address a f 5 'Tk d V)-frr City vC ILS State X, ZIP Code 70 72 County c vt � - -- E-mail Address �04,1 1r1�c.,r%/ Cc5,i_crr1c S-t /Cv Telephone No :ZG ,--L 3 -0 `_�t7 i0 - Fax 76 -1 _3 j `l 3) Reason for rescission request (This is Leauired information Attach separate sheet if necessary) ❑ Facility closed or is closing on _, All industnaf ,activities have ceased such that no discharges of stormwater are contaminated by exposure* to industrial actiaitie,, ci 1`nF larial5 ❑ Facility sold to on _ If the facility will continue operations under the new owncl it may be more appropriate to request an ownership change to rotssue to permit to the new owner [$f Other � � v _ � t (i (� -f /-L "S 5 4) Certification 1, as an authorized representative, hereby requ(J,. rescission of coverage tinder the NPDES Stormwater Permit for the subject facility F am familiar with the information contained in this request and to the best of my knowledge and belief such information is true, complete and accurate Signature _ _ Date _ 3/7,) ,Jvl�i✓stL �l f�4n�2v �+1Vr✓t��'1 /"� c.�'f,-/ ��` �! G�C✓ Print or type name of person signing above Title Please return this completed rescission request fo-m to t)_4 - - , n, '1 ilu s r lit rn [ N/A r,r .q I 11 ,r rpl { � I i l 1 v[ 4 , —I 1 IF! SW NPDCS Permit Coverage Rescission Stormwater Perinitting Unit 1617 Mail S,_rvice Center Raleigh, North Carolina 27699-1617 x S ' Mickey, Mike From Mickey, Mike Sent Wednesday, March 30 2011 2 30 PM To 'Johnie alexander@concretesupplyco com' Subject Concrete Supply - Dade County permits Attachments Sto rmwater- N P D ES-Resc iss ion -Form pdf Johnie — Per our discussion today, it is my understanding that Concrete Supply Company Just has one ready mixed concrete facility in Davie County For some unknown reason, our computer data base shows that Concrete Supply holds three NCG14 permits for Davie County You and I agreed that the correct permit number is NCG140358 for the existing facility at 215 industrial Blvd in Mocksville The following two permits held by Concrete Supply need to be voided NCG140238 and NCG140344 Attached is the rescission form Please complete one form for each permit and submit the originals to our Central Office in Raleigh and a copy to my attention As for the existing facility covered by NCG140358, our records show the mailing address as 3823 Raleigh Street, Charlotte, NC 28206 If this address is incorrect, please provide an updated mailing address in the cover letter that goes to Raleigh with the rescission forms so we can get that straight also Thanks for your help Let me know if you have any questions Mike Mike Mickey Mike MickevCZDNCDENR eov NC Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Phone (336) 771-4962 FAX (336) 771-4630 E mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties Mickey, Mike From Mickey Mike Sent Monday, March 28 2011 4 44 PM To johnie alexander@concretesupplyco com' Subject Dave County Permits? Attachments Concrete Supply Davie County doc Johnie — Please find screen shots attached showing three NCG14 permits in Davie County issued to Concrete Supply Two are active and one is expired The annual fee is being paid for all three Our files indicate that permit No NCG140358 is for the facility at 215 Industrial Drive Look it over and give me a holler back Thanks, Mike Mike Mickey Mike MickevCu)NCDENR eov NC Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Phone (336) 771-4962 FAX (336) 771-4630 E mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties Qualitative Limit r Vehicle Limit r WasleWater Limit r Comments r History r Inspections r Incidents r Enroicements r Violations Details 1 Detaits 2 Billing r Events r Reg Acimties r Affdialions Reviewers f Relate s 11 r Analytical Lima ermit CG140� 358 Version 2 0 T � Slat Active PermilTypeReady Mix Concrete StormwaterWastewaterDischarge COO Permit Classification COC Primary Related PermitNCGt 40000 Program Category NPDES SW 'Adman Region winston Salem Facility Concrete Supply Company MecksvNe plant Qetads County Davie Owner Concrete Supply Co ProlectType tRenewwal n Dates �v Issued DflJOtf20p9 Ong Issued 02120l2008 ❑ Major Permit ❑ Has Subsurface Drains Tractnng Slip Effective 08J01f2009 Statutory 05f27J2D09 -- } Now Farm Q Existing Farml Farm ir Expire OflJ30l2D11 Inactive --- -- © Innovative Avail Acres SOC Details ❑ RalnbreakAr Device ❑ OIC Present Last Updated By bimsprod cron Last Updated On t112112010 1 37 AM� <gack Next> t finish Qr ancel I Ready I~ SID PMD1 I I [ Details 2 j Billing j Events [ Reg Activities A>fihations j Reviewers f Related Permits j Oulfall Analytical Limit f Permit NCG140358 Version 20 Status Active T �J Facility Concrete Supply Company Mocksvdle Pkant Billing Contact Naitor St Find Per Find Org Malnt Ir County flavie Address 2151ndusirial Blvd Title F Fee Category IStDrmwaterWastewater discharge { 005 + Address 2 Phone �(336)751 11 p7 Ext Bill Month 2 February d Ong Bilied 02f20J2008 City Mocksville T� State NC ZIP 27028 [{g Normal Q Fast Track Q Express Review invoice Type I 1PenDc1 Worl Period Begini Period End Billie Month I Due Date I invoiced I Amount I Paid I Balance I status Permit Annual Fee 112011 02101/2011 01131J2012 February 0211212011 2011PROD0406 $1000DJS0_00 I$1040 Overdue Permit Annual Fee 112010 021'01/2010 01012011 February 03AW2010 12010PROD1271 $100 of:J $100 o0J $0 OD— Paid Permit Annual Fee 2009 02f01f2009 01131l2010 February 04f18f2009 2009PR002796 si 00 00J S10D ODJ $0 00� Paid Permit Application Fee 2005 1 JOW29f2i[105 12005PLD09406 ISGO OOJ S8D OOJ $0 00 Paid Fjeprinttnvoite finterPayments MatntainInvoice @ack next► Finish Qancel 114lrvoicesfound (Ready I ISID PMBI Maintain Permit rW pualllatrvetrmd VehiclelJmd WasteWaterLrmit Comments History Inspections Incident n is VlelatlonS Details 1 Details 2 r Bming r Events r Reg Actrinties Atrhahons Renewers Related Permits r 0 II r Analytical Limit Permit C0140238 Varsion 30 atus Actrye _ Save Permit Type ReadyMrxCencreteStormwaterJWastewater0ischargeCOC *r Permit Classification COO Primary Related Permit NCG140000 Program Category NPDES SW 'Adman Region Winston Salem + Facility Concrete Supply Co Mocksnlla County Davie Owner Concrete Supply Co ProleciType Renewal Dates Issued 08J01f2009 Ong Issued 1 iJ27l1996 ❑ major Permit Elective TM,J2009 Statutory 05/27f2009 ❑Has Subsurface Drains Traclong Slfp —� Q NewFarm Q Existing Farm Farm* Expire 06J3012011 Inactive ❑ innovative Avail Acres 80C Delatls ❑RainbreakerDence ❑ OIC Presant Last Updated By bimsprod cron Last Updated On I1f200010 1 37AM tack Next> Finish G ncel Ready ��..� SID PMD1 Perms Facile County Status Active ,� oxan� der Johnie Ind Por Flnd Org Maint kPOBox 5247 Title Phone ' 704) 372 2930 Ext ,Charlotte State ENE]ZIP i28299 Invoice Type I PenodVearlPericid Begin Penod End Billin Month Due Data Invoice of Amount Paid Balance I Status Permrl Annual Fee 2010 08f01f2010 07131f2011 August 08f07f2010 2NOPRO86624 $JOG00J31ODooJSUO—JPaid Permit Annuat Fee 2099 081011'2009 07f31f2010August NitU2009 2309PROO8235 $10030J$100OQJs000—JPaid PermltAnnual Fee 2008 08;01f2008 072U2009 August 10f170008 2008PROO8950 $100 OOJ $100 0OJ s0 ODD Pald Permit Annual Fee 07f31f2008 gust 1DA8f2007 2007PROO9211 $JOGOOJ$Too5 SoOO Paid PermitAnnual Fee OW01f2005 07f31f2007 August 1014912006 2006PROO9305 sea OOJ $80 00J $a a Pald PermitAnnual Fee 1200708101f2007 08f01f2005 07f31f2M08 Au ust I Of14f2005 2005PROD8718 sea OOJ Sea 00 s0 OD Paid Permit Annual Fee 08f01f2004 07f31f2035 August 10J17f2004 2004PROD5706 $80 00J $80 09._J $0 Opp Paid PermitAnnual Fee OWN f2003 J07f31t2OO4 August 1 N24f2003 2003PR004445 $gp pOJ s80A0J $0 OO— Paid _Repnnt Invoica tinter Payments Maintain fnvalce �@ack htexty Eimsh Mantel Qualitative Limit r Ve WasteWater Limit Comments History r inspections r Incide cements ' Violations Details 1 s 2 r Billing is r Reg Activities r AfAliations r Reviewers rRelated Permits utfall Analytical Lund Qermt—NCGI �40Version 1 0 T �— Status Expired have PermrtType Ready Mix Concrete StormwaterNVastewaterDischarge COC Permit Classification ICOC Primary Related Permit NCG140000 1 Program Category NPDES SW `Adman Region Winston Salem -, Facility ,Concrete Supply Co-Dawe Qetatls County Davie Owner Concrete Supply Ca Maintain Pro;ectType ItNew Protect v Dates Issued 06127f2003 Orig Issued 0612712003 ❑ Major Permit f -- Effe trve O6f27f2003 7 Statutory- ❑ Has Subsurface Drains Tracking 311p ta New Farm (j Existing Farm Farm# Expue 07131f2004 Inactive ❑Innovative Avail Acres SOC Ralnwaaker Device ❑ OIC Present Last Updated By bimsprod cron Last Updated On 8112004 12 5S AM Back Next= Finish ncel I Ready SID I I I f Details 2 ( Billing [ Events j Reg Activities Amliations [ Reviewers [ Related Permits [ Outfall [ Analytical I Permit iNCG140334 Version 10 Status Expuetl T �$ e Facility Concrete Supply Co Davie Billing Contact Naylor Steve Fittd Per Find Org Taint County Davie Address 1 PO Box 5247 ^^ Title Fee Category stormwatebWastewater discharge COCs Address 2 —] Phone �0 I Bill Month 6 June Ong Billed 0612712003 City !Charlotte otte State NC Zip 28299 L/t��al Q Fast Track Q Exprass Review ^I Invoice Tye Period Year 3eriod Begin Period End Bilhn Month Due Date Invoice * Amount Paid Balance Status Permit Annual Fee 2010 10 651310011 June 0610512D10 2010PROD4735 $100 QD $100 QDJ $Q_DQ_ I Permit Annual Fee 2009 6J0112009 051310010 June 0711012009 2C09PR006461 1100 00J 5100 00J $0 1 Paid Permit Annual Fee 2008 6101f2008 05f310009 June OB12112908 2008PROD6912 S100I s100<00.J sjo-I Paid Permit Annual Fee 2007 610112007 05f310008 June OBA712007 2007PR007025 $801 $801 s0 I Paid Permit Annual Fee 2006 6f0112006 05fW1 2007 June 0BA812006 2006PR007189 $601 $BB 1 s0 I Paid Permit Annual Fee 2005 0619112005 05131f2006 June 081181'2005 2005PR006821 sB0 00� $0 00� sB0 00 Overdue Permit Annual Fee 2004 O6f01f2004 05l3112005 June 08110f2004 2004PR004261 $80 00, $80 00-1 $p 00 Paid Reprint Invoice Enter Payments Maintain Invoice � $ack �Pxi> Finish cancel 117 invoices found Ready ISID PMBI A -I'MA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H Sullins Dee Freeman Governor Director Secretary May I8, 2010 Mr Johnie Alexander Concrete Supply Company P 0 Box 5247 Charlotte, NC 28299 Subject General Stormwater Permit Inspection Concrete Supply Company — INIocksville Facility Certificate of Coveraoc No NCG140358 Dade County Dear Mr Alexander On May 14, 2010, I'Alke Mickey of this office met with you and Steve Naylor to perform a General Stormwater Permit Inspection at the Concrete Supply Company facility in Mocksville, NC The inspection found the facility to be in compliance vN ith the state issued storrnwater permit This inspection evaluated the five (5) areas designated on the attached inspection form Observations from each area are addressed below 1 Permit Concrete Supply Company holds Certificate of Coverage 9 NCG14O358 for the discharge of stormnater and process wastewater from the site The permit expires next on June 30, 2011 2 Records/Reports Part II, Section A of the permit requires the development of a Storm-,Nater Pollution Prevention Plan (SPPP) A copy of the SPPP was reviewed during the inspection This plan was found to be thorough and complete and addressed all items as outlined by the permit 3 Facility Site Review Observations at the site found the facility to be clean and well managed No concerns or problems were noted A single 10,000 gallon diesel tank is located inside a concrete block containment structure I he handle to the release valve is removed once draining is complete 4 Efflucnt/Receiving Waters The SPPP site map identified one stortmvater/wastewater outfall for the, facility located at the overflow spillway of the wet detention basin All stormwater and process wastewater is routed through the basin The mixing drum cleanout wastewater is routed through a recycle. pit ahead of the basin I he pH of recycle, pit wastewater can be adjusted prior to pumping to the wet detention basin The pit also receives stormv�ater off the site Excessive rainfall can cause the pit to overflow into the basin without pH adjustment Stormwater from the property eventually reaches an unnamed tributary to Leonard Creek, Class "C" Waters in the Yadkin -Pee Dee River Basin North Carolina Division of Water Quality Winston Salem Regional Office Location 585 Waughtown St Winston Salem North Carolina 27107 Phone 336 771 50001 FAX 336 771-46301 Customer Service 1 877-623 6748 Internet www ncwaterquallty org An Equal Opportunity 1 Affirmative Aeon Employer NorthCarohna Naturally Concrete Supply Companv Page #2 5 Monitoring Prop -ram Part 1I, Section B of the permit requires the collection of annual analytical samples of stormwater runoff from the site Part II, Section C of the permit requires the collection of annual analytical samples of the following process wastewaters generated at the site 1) vehicle and equipment cleaning, 2) recycle system overflow, 3) raw material stockpile wetting and, 4) mixing drum cleanout Since all stormwater and process wastewater are routed through the wet detention basin prior to discharge, a single sample can be collected from the overflow spillway of the wet detention to satisfy the above requirements As you are aware, all analytical monitoring results must be submitted to the Division on form SWU-241-080109 no later than 30 days from the date the facility receives the sampling data from the laboratory It was noted that a pH value of 9 3 on 219/10 exceeded the cutoff concentration of 9 0 This was due to excessive rainfall this winter that caused the pit to overflow into the basin w ithout pH adjustment The monitoring requirement (Table 3) specific for on -site vehicle maintenance is not required since the facility uses < 55 gallons of new motor oil when averaged over the calendar year Routine truck maintenance occurs at the main shop in Charlotte Part 11, Section F of the permit requires that qualitative (visual) monitoring be performed and documented semi-annually of the combined stonnwater/process wastewater discharge This monitoring was last performed on 1113109 and 2/9/10 The qualitative records do not need to be submitted to the Division, however, the records must be kept on file at the facility for a period of fi\ e vears Your efforts to comply with the stormwater permit are appreciated If you have anv questions concerning this letter, please contact Mike Mickey or me at (336) 771-5000 cc Central Files — SWP WSRO Sincerely, Steve W Tedder Water Quality Regional Supervisor CAROLINAS AGC PINNACLE AWARD WINNER BEST SUPPLIER JOHNIE ALEXANDER ENVIRONMENTAL MANAGER OFFICE (704) 372 2930 EXT 2071 MOBILE (704) 309 8738 3823 RALEIGH STREET 28206 FAX (704) 334 8650 PO BOX 5247 NEXTEL ID 150 202 131 CHARLOTTE NC 28299 E MAIL Johnie Alexender@ConcreteSupplyCo com Form Approved OMB No 2040 0057 ^"a Approval Expires 8 31 98 United States Environmental Protection Agency,Washington D C 20460 Section A National Data Svstem Coding Transaction Code NPDES No Yr/Mo/Day Inspection Tvpe Inspector FacilityType N 5 NCG 140358 10-05-14 C S 2 Facility Evaluation Rating BI QA Reserved 1 N N Section B Facility Data Name and Location of Facility Inspected Entry Time Permit Effective. 1000 hrs Date Aug 1, 2009 Concrete Supply Company-Mocksville Plant 215 Industrial Blvd Mocksville, NC 27028 Exit Time Permit Fxpiration 1040 hrs Date June 30, 20l 1 Name(s) of On -Site Representative(s) Title(s) Phone No(s) Mr Steve Naylor Plant Manager (336) 751-9128 Mi Johnie Alexander Environmental Manager (330) 372-2930, ext #2071 N ime, Address of Responsible Official Title Environmental Manager Mr Johnte Alexander Phone No Contacted � Yes Concrete Supply Company C Office (704) 372-2930 P 0 Sox 5247 Cell (704) 309-8738 Charlotte, NC 28299 Section C Areas Evaluated During Inspection (check only those areas evaluated) 4 Permit NA Flow Measurement NA Operations/Maintenance NA Sewer Overflow 4 Records/Reports Monitoring Program NA Sludge Handling/Disposal NA Pollution Prevention 4 Facility Site Review NA Compliance Schedules NA Pretreatment 4 Ef€]uent/Recei� mg Waters NA Laboratory Stormwater Section D Surnmar) of Findings/Comments See the cover letter and attached inspection form for specific comments Nlame(s) and Signature(s) of Inspectors Agency/Office/Telephone Date nLLn DWQ / WSRO / (336) 771-5000 Signature of Revi er Agency/Office Date r' DWQ / WSRO / (336) 771-5000 EPA Form 3560-3 (Rev 9-94) Permit NCG140358 Owner Facility Concrete Supply Co Inspection Date 05/14/2010 Inspection Type Compliance Evaluation Reason for Visit Routine Storrnwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ® ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ®❑ ❑ ❑ # Does the Plan include a Narrative Description of Practices ? ®❑ n n # Does the Plan include a detailed site map including outfall locations and drainage areas? ®❑ Q ❑ # Does the Plan Include a list of significant spills occurring during the past 3 years? ®❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ® ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ® n n n # Does the Plan indude a BMP summary? ® 0 ❑ ❑ # Does the Plan Include a Spill Prevention and Response Plan (SPRP)? ® Cl n ❑ # Does the Plan include a Preventattve Maintenance and Good Housekeeping Plan? ®❑ ❑ ❑ # Does the facility provide and document Employee Training? ®❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ®❑ fl ❑ # Is the Plan reviewed and updated annually? ® ❑ 0 ❑ # Does the Plan include a Stormwater Facility Inspection Program? ®❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ® n n n Comment The SPPP for the facility was found to be thorough and complete The SPPP addressed all items as listed in Part II, Section A of the permit Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ®❑ 0 ❑ Comment Qualitative monitoring is performed per Part ll Section F of the permit The last three visual monitoring events occurred on 4/9/09 1 113109 and 219110 Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? a n n ) # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? n n ® ❑ Page 3 Permit NCG140358 Owner Facility Concrete Supply Co Inspection Dale 05/1412010 Inspection Type Compliance Evaluation Reason for Visit Routine Comment Part II, Section B of the permit requires analytical monitoring of stormwater and Part II Section C requires analytical monitoring of the following process wastewaters 1) vehicle/equipment cleaning 2) recycle system 3) raw material stockpile wetting and, 4) mixing drum cleanout Since all stormwater and process wastewater is routed to the recycle pit and the wet detention basin a single sam ple collected at the detention pond spillway satisfies the above requirements A 9 3 pH value obtained on 219110 exceeded the 9 0 cutoff concentration for pH This was due to excessive rainfall causing the pit to overflow into the basin without pH adjustment Under normal operating conditions, pH is adjusted using a carbon dioxide gas unit when pit water is pumped to the basin The monitoring requirement for on -site vehicle maintenance (Part II Section B, Table 3) is not applicable si nce this facility uses <55 gallons of new motor oil/month Routine truck maintenance is conducted at the shop in Chat kft Permit and Outfalls # Is a copy of the Permit and the Certificate of Coverage available at the site? # Were all outfalls observed during the inspection? # If the facility has representative outfall status is it properly documented by the Division? # Has the facility evaluated all illicit (non stormwater) discharges? Comment Secondary containment is provided for a 10 000 gallon diesel tank Stormwater releases from the containment area are documented on a secondary release form The handle from the release valve is removed in between releases to prevent tampering Yes No NA NE mnnp ®nn❑ ❑❑M0 M1)00 Page 4 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMTT NO NCG140000 CERTIFICATE OF COVERAGE No NCG140358 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELINUNATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215 1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Concrete Supply Co , LLC is hereby authorized to discharg6itormwater from a facility located at P.'+ti�css trasffewa7�s e�� K�f Concrete Supply Co — Mocksville Plant � 215 Industrial Blvd Mocksville Davie County to receiving waters designated as unnamed tributary to Leonard Creek, a class C water in the Yadkin -Pee Dee River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, H, III, IV, V, and VI of General Permit No NCG140000 as attached This certificate of coverage shall become effective April 11, 2014 This Certificate of Coverage shall remain in effect for the duration of the General Permit Signed this day April 11, 2014 for Tracy E Davis, P E , Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F Easley, Governor William G Ross Jr, Secretary Coleen H Sullins, Director Febi nary 20, 2008 Mr Loren Wild Concrete Supply Company POB 5247 Chailotte, Noith Caiolina 28299 Subject General Permit No NCG140000 Concrete Supply Co MocksvilIe Plant COC NCG 140358 Davie County Dear Mr Wild In accordance with your application for discharge permit received on September 20, 2005, and again on November 17, 2005, we are forwarding herewith the subject certificate of coverage to discharge under the subject state - NPDES general permit 1 apologize for the lengthy delay on my desk T�is permit is issued pursuant to the requirements of North Carolina General Statute 143-215 1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated May 9, 1994 (or as subsequently amended) If any parts, measurement frequencies, or sampling requirements contained to this permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application Unless such demand is made, this certificate of coverage shall be final and binding Please take notice that this certificate of coverage is not transferable except upon the action of the Division of Water Quality The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act, or any other federal or local governmental permit that may be required If you have any questions concerning this permit, please contact Ken Pickle at telephone number (919) 733-5083 ext 584 Sincerely, e� for Coleen H Sullins cc Winston-Salem Regional Office DWQ Central Files Stormwater Permitting Unit Files swu 259 011001 1617 Mail Service Center Raleigh North Carolina 27699-1617 Telephone 919-733-5083 FAX 919-733 9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO NCG140000 CERTIFICATE OF COVERAGE No NCG140358 STORMWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215 1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Concrete Supply Company is hereby authorized to operate a process wastewater treatment system consisting of automated pH control equipment and a four -chamber recycle system for truck wash down and drum wash wastewaters, a wet detention pond and sedimentation pond for aggregate storage drainage wastewater, loading area wash down wastewater, and stormwater, and is hereby authorized to discharge process wastewater and stormwater from a facility located at Concrete Supply Company — Mocksville Plant 215 Industrial Boulevard Mocksville, North Carolina Davie County to receiving waters designated as unnamed tributary to Leonard Creek, a class C water in the Yadkin -Pee Dee River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, 111, IV, V, and VI of General Permit No NCG 140000 as attached This certificate of coverage shall become effective February 20, 2008 This Certificate of Coverage shall remain in effect for the duration of the General Permit Signed this day February 20, 2008 for Coleen H Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO NCG140000 CERTIFICATE OF COVERAGE No NCG140358 STORM WATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215 1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Concrete Supply Company is hereby authorized to operate a process wastewater treatment system consisting of automated pH control equipment and a four -chamber recycle system for truck wash down and drum wash wastewaters, a wet detention pond and sedimentation pond for aggregate storage drainage wastewater, loading area wash down wastewater, and stormwater, and is hereby authorized to discharge process wastewater and stormwater from a facility located at Concrete Supply Company — Mocksvilic, Plant 215 Industrial Boulevard Mocksville, North Carolina Davie County to receiving waters designated as unnamed tributary to Leonard Creek, a class C water in the Yadkin -Pee Dee River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, II, III, IV, V, and VI of General Permit No NCG 140000 as attached This certificate of coverage shall become effective February 20, 2008 This Certificate of CoN erage shall remain in efxect for the duration of the General Perrnk Signed this day February 20, 2008 4.) ed��' for Coleen H Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission [Fwd Concrete Supply Company - Mocksville] f Subject [Fwd Concrete Supply Company - Mocksville] From Jenifer Carter <Jenifer Carter@ncmatl net> Date Tue 12 Feb 2008 12 44 47 -0500 1 o Steve Tedder <Steve Tedder@ncmatl net> CC Mike Mickey <mike mickey@ncmatl net> - Steve, I just wanted to pass this by you before I respond I agree with Ken on getting them permitted once and for all Any objections? Jenifer ------- Original Message -------- Subject Concrete Supply Company - Mocksville Date Tue, 12 Feb 2008 11 47 59 -0500 From Ken Pickle <ken pie,kle a ncmatl net> To Jenifer Carter <fenifer Cartel a,ncmatl net> CC Bethany Georgoulias <bethany georgoulia5 a,ncmail net>, Bradley Bennett <Bradley Bennett @ncmail net> Jenifer, a) This existing facility made application for coverage under NCG14 in September 2005 (incomplete) and then again in October 2005 (again incomplete) We again requested additional information in March 2006, but have had no direct written response or resubmittal from them addressing the March 2006 add -info letter Around the March 2006 time frame a new environmental manager joined the company b) We had a confusing second submittal of the application forms (NOI) in August 2007 I advised the current environmental manager that the original application was still live in our system, and that we were waiting for their response to our March 2006 add -info letter He subsequently reported that he had never seen our March 2006 letter I advised him that the more expeditious path now might be for me to provide a refreshed review of their submittal, rather than to send him a copy of the March 2006 letter c) Upon beginning that re -review, and considering the lengthy delay on my desk, I now think our best path is to issue the Certificate of Coverage under NCG14 for this site The submittal is close enough to my current idea of an adequate submittal This was one of my first attempts to have the permitting function support our enforcement emphasis in the concrete industry, and my thinking has evolved a little since then Given the time that has passed, I'm ready to permit this site without further delay /I'm seeking WSRO concurrence that you support issuing the COC / d) You may recall that early on (September 2005) in discussions about this existing site and a sister existing site submitted the same time (Central Carolina Concrete in W-S), we agreed with WSRO that we would I oft 2/12/2008 1 02 PM tFNvd Concrete Supply Companv ,'Mocksville] 7 withhold coverage under the permit until the application was complete We did not anticipate that there would be the lengthy delay on my desk Further, my idea of what a sufficient submittal includes has changed since then, and I think for Mocksville (and possibly W-S), we should get it (and maybe W-S, too) under permit without further delay e) As I understand it from the past Mocksville submittal documents and from discussions this week with their environmental manager, the facility exists, the recycle system is built and appropriately sized, the pH correction equipment is on site, and it appears that the facilities are in place to appropriately address wastewater flows /So, to re -iterate, I'm seeking concurrence that we can move forward with permit coverage at Mocksville I'll re -review the other plant (Winston-Salem) submittal later this week, and follow up with you on our best course of action on that one, too / Ken NC DENR Winston-Salem Regional Office Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Voice (336) 771-4957 FAX (336) 771-4630 2 of 2 2/12/2008 1 02 PM To STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY FAX (919) 733-9612 °n a i.■,,`a41'j�R + `��X�„ 4 yy",,i i1FIJi�''llr^fs JW �'�MyR,'�, �yr�, Fa�I xr�``�du H1+�A� �l��'R �,�1 S �tl"h� �. 1}J���'��r .��Y �rv �I lS� {i� �✓� i`�'yt'��' +�'k��9 }� hr F1'Y%yryY; J' �t„i Pw VfNa r YM� 5}ya 9,tkf a t 4 ! r r, a:"s A`7 Y �i rri 5i ye afFP{^*yI �� i rf � rji fiYk f�SS,�S4r 1p p�sl�� �+°x �°i r'j" ',"��7�a15N 4j ,Ilr 'h '1 r b h h r' Ni;u�Fa �!nFr iYrlkrrr >� �ay6 ,.nr�a sEi,.. x1J7 �,�p,lp,J.111��n'a➢3.1lr a.nr��tk�S.a: L, J'i �.'��tf�'4°�i�....r ii.�s�.a��nhGi��y 4t �A6L"� �L.r1A^`�W,�ri'�Juie �i °A�ki ikdu a'ktw:.i. �L °�., .p.,9�.:a�t��r,Ip ',�o-r� � Loren Wild, Concrete Supply Company Fax (704) 343-0271 From Ken Pickle, Stormwater Permitting Unit, Date January 16, 2008 Division of Water Quality Phone (919) 733-5083 ext 584 Pages 7 E-mail Ken pickle@ncmail net Urgent For review Please comment Per your request FYI, no action Please recycle Subject: March 2006 letters on Mocksville and WS submittals Loren, Here are my two letters of March 17, 2006 on the Mocksville and WS submittals Essentially, I've been waiting for responses to these letters As we discussed today, at this point in time the most productive thing might be for me to provide a current review of the Trigon submittals So, please don't initiate a response to the questions in the March 2006 letters, which were based on the engineering packages provided by Grey Engineering (Mocksville) and Chas H Sells, Inc (WS) The original submittals are still live applications in our office, so the additional NOI forms and checks are not necessary The two checks (from Concrete Supply Company to the Division of Air Quality (7), #64800, 9/17/07, $100, for WS, and from Trigon Engineering, #2006, 8/1.4/07, $80, for Mocksville) are still on my desk I can return yours to you, or I can destroy it here Please provide instructions Given that we are discovering a breakdown in communication on these two projects, it may be helpful for me to provide a short status report on permitting and ATC for all of the Concrete Supply Company submittals currently in our office I'll have that to you this week Ken Re Concrete Supply Company - two submittals Subject Re Concrete Supply Company - two submittals From Jensfer Carter <Jemfer Carter@ncmail net> Date Wed, 20 Feb 2008 08 52 47 -0500 To Ken Pickle <ken pickle@ncmail net> Sorry for the late response to this one I wanted to discuss it with Tedder but he was out all last week tending his mother (had a stroke) He said he's fine with your plans below, as am I Thanks for getting the ball(s) rolling again Jemfer Carter NC DENR Winston-Salem Regional Office Division of Water Quality 585 Waughtown Street Winston-Salem, NC 27107 Voice (336) 771-4957 FAX (336) 771-4630 On 2/14/2008 1 17 PM, Ken Pickle wrote Jenifer, a) We've already spoken about the Carolina Concrete Company facility in Mocksville, and my inclination to permit this site based on the submittal documents received to date My only hesitation is around our agreement with WSRO in 2005 to HOLD the permit pending response to my add -info letter Now I think the submittal is good enough b) However, remember that two projects came in together The other is Central Carolina Concrete (same parent company) in W-S On it, the submittal is NOT good enough I'm considering returning the package based on non -response to my 2006 add -info letter That would leave the site without a permit, and without a permit application pending How would WSRO react to that, given all the relevant circumstances (ie my delay, their delay) Ken of 1 2/20/2008 9 26 AM Concrete Supply Company - Mocksville Subject Concrete Supply Company - Mocksville From Ken Pickle <ken pickle@ncmail net> Date Tue, 12 Feb 2008 11 47 59 -0500 To Jenifer Carter <Jemfer Carter@ncmail net> CC Bethany Georgoulias <bethany georgoultas@ncmail net>, Bradley Bennett <Bradley Bennett@ncmail net> Jenzfer, a) This existing facility made application for coverage under NCG14 in September 2005 (incomplete) and then again in October 2005 (again incomplete) We again requested additional information in March 2006, but have had no direct written response or resubmrttal from them addressing the March 2006 add -info letter Around the March 2006 time frame a new environmental manager Doined the company b) We had a confusing second submittal of the application forms (NOI) in August 2007 I advised the current environmental manager that the original application was still live in our system, and that we were waiting for their response to our March 2006 add -info letter He subsequently reported that he had never seen our March 2006 letter I advised him that the more expeditious path now might be for me to provide a refreshed review of their submittal, rather than to send him a copy of the March 2006 letter c) Upon beginning that re -review, and considering the lengthy delay on my desk, I now think our best path is to issue the Certificate of Coverage under NCG14 for this site The submittal is close enough to my current idea of an adequate submittal This was one of my first attempts to have the permitting function support our enforcement emphasis in the concrete industry, and my thinking has evolved a little since then Given the time that has passed, I'm ready to permit this site without further delay /I'm seeking WSRO concurrence that you support issuing the COC / d) You may recall that early on (September 2005) in discussions about this existing site and a sister existing site submitted the same time (Central Carolina Concrete in W-S), we agreed with WSRO that we would withhold coverage under the permit until the application was complete We did not anticipate that there would be the lengthy delay on my desk Further, my idea of what a sufficient submittal includes has changed since then, and I think for Mocksville (and possibly W-S), we should get it (and maybe W-S, too) under permit without further delay e) As I understand it from the past Mocksville submittal documents and from discussions this week with their environmental manager, the facility exists, the recycle system is built and appropriately sized, the pH correction equipment is on site, and it appears that the facilities are in place to appropriately address wastewater flows /So, to re -iterate, I'm seeking concurrence that we can move forward with permit coverage at Mocksville I'll re -review the other plant (Winston-Salem) submittal later this week, and follow up with you on our best course of action on that one, too / Ken I of 1 2/12/2008 11 48 AM Re Central Carolina Concrete Subject Re Central Carolina Concrete From Ken Pickle <ken pickle@ncmail net> Date Tue, 15 Jan 2008 07 50 56 -0500 To loren wild@concretesupplyco com CC Henry Batten <Henry Batten@concretesupplyco com>, Jenifer Carter <Jenifer Carter@ncmail net> BCC Bradley Bennett <Bradley Bennett@ncmatl net> Loren, Thanks, that's great I'll be available this week Tuesday after 11 00, Wednesday except for 1 00-2 00, Thursday all day, Friday morning I've also picked up the Mocksville file It looks lake I have similar confusion about Mocksville, too My files show the following progression and status, similar to WS a) I received the first NOI submittal 9/20/05, with a follow-up submittal of talcs, drawings, and lab reports on 11/17/05 b) My 3/17/06 letter requesting additional information c) On 8/16/07 we received the confusing submittal of a second, unnecessary NOI for this fatality d) And again, I still can't tell how this facility intends to insure that the wastewater discharges are within permit limits From my files it appears that the site is discharging wastewater and stormwater without a permit, and I'm not sure what progress, if any, is underway Let's cover both Mocksville and Winston-Salem in our conversation later this week Thanks, Ken loren wild@concretesupplyco co m wrote Ken I will set up a time that Henry Batten and I can call you together so we can get these ironed out and going again I did receive Croft Thanks Loren Cell 704 309 4418 Sent from my B1ackBerry® wireless device -----Original Message ----- From Ken Pickle <ken pickle@ncmail net> Date Mon, 14 Jan 2008 17 15 50 To Loren Wald <loren wild@concretesupplyco com> Cc Jenifer Carter <Jenifer Carter@ncmail net> Sub]ect Central Carolina Concrete Loren, I packed up the Central Carolina Concrete, Winston-Salem, file today to try to make progress on your several submittals I believe by now you will have received the approved permit for the Croft site in Charlotte, so I'm trying to catch up My files show the following for Central Carolina in WS a) We received the CCC application for a permit (NOT form) on September 20, 2005 The application was not complete b) Subsequently a single page of water usage calculations in support of the NOT was received on 11/17/05 c) On 3/17/06 DWQ addressed a request for additional information to your predecessor, David Mock d) On 6/30/06 DWQ met with you and Henry Batten to clarify DWQ requirements on all l of2 1/15/2008 7 51 AM Re Central Carolina Concrete submittals in general, and including the Central Carolina Concrete site, as well e) On September 11, 2007 DWQ received another NOI for the same site in Winston-Salem I'm confused, because another NOI is not required The new NOI is not specifically responsive to the requests in my March 17, 2006 letter I stall cannot tell how this site plans to meet the permit limits an wastewater discharges f) From my files, it appears that you are operating without a permit to discharge either stormwater or wastewater, and I'm not sure what progress, if any, is underway Loren, it's clear that communications have broken down between us Please contact me to get us back on track at Central Carolina Concrete in Winston-Salem Thank you, Ken Pickle DWQ stormwater (919) 733-5083 Permitting Unit x 584 2 of 2 1/15/2008 7 51 AM Concrete Supply Company add -info letters Subject Concrete Supply Company add -info letters From Ken Pickle <ken pickle@ncmail net> Date Fri, 17 Mar 2006 11 53 50 -0500 To Paul Rawls <Paul Rawls@ncmail net> CC Bradley Bennett <Bradley Bennett@ncmail net> Paul, FYI, and in accordance with our promise date, these two add -info letters will go out today to Henry Batten's engineer David Mock via email (already accomplished this morning) and signed letter (presumably this afternoon by snail mail) Add -info letter summary Mocksville - Recycle system permittable as presented, but the applicant's submittal does not predict permit compliance at the discharge point for flows from aggregate storage and from batch plant washdown KBP will continue processing the permit application upon receipt of an engineering argument predicting compliance with the permit limits for these two other wastewaters Add -info letter summary, Winston-Salem - The recycle system is similar to Mocksville, and the information presented is promising, but the application does not yet present sufficient information for me to concur that it will not discharge in response to the 25-yr, 24-hr storm The submittal does not predict permit compliance at the discharge point for flows from aggregate storage and from batch plant washdown KBP will continue processing the permit upon receipt of an engineering argument predicting compliance with the permit limits for these two other wastewaters Ken 'Add -info Concrete Supply Co Mocksville doe Add -info Concrete Supply Co, W-S doe Content -Type application/msword 1 Content -Encoding base64 Content -Type application/msword Content -Encoding base64 1 of 1 3/17/2006 11 54 AM Mocksville facility additional information request Subject Mocksville facility additional information request From Ken Pickle <ken pickle@ncmat] net> Date Fri, 17 Mar 2006 09 05 25 -0500 To david mock@coneretesupplyco com David This letter is off my desk, and on its way to you The letter is more verbose than what I normally prefer but I wanted to record my thinking for both our benefits As I indicated yesterday I think I already know the answers to some of the questions in the letter, but for my purposes, I'd like to have you re -answer anyway I'm Dust concerned that I'll forget the basis of my thinking at this site if we don t get at least a portion of it in writing Contact: me with any questions Thanks Ken (919) 733-5083x584 Add -info Concrete Supply Co Mocksville doe Content -Type application/msword Content -Encoding basc64 of 1 3/20/2006 8 41 AM Mocksville submittal review Subject Mocksville submittal review From Ken Pickle <ken pickle@ncmail net> Date Thu, 16 Mar 2006 10 38 57 -0500 To david mock@concretesupplyco com Hi David, I have made a preliminary review of the Mocksville submittal and would like to discuss a few points with you on it I expect to be sending you a letter NLT Friday, tomorrow, requesting additional information or changes Are you available to contact me today in advance of my letter? I'll be turning my attention to the Winston-Salem submittal, this afternoon and would anticipate a second contact between us either late today or first thing Friday Can you be available for that, too? I expect the same sort of questions on W-S - 3ust an attempt to clear up any of my misunderstandings, and a heads -up for you on my remaining concerns Thanks, Ken Pickle (919) 733-5083x584 1 of 1 3/20/2006 8 41 AM i �\ r ���, of WArF9 o � Mr David Mock Concrete Supply Company 3823 Raleigh Street Charlotte, North Carolina 28206-2042 Dear Mr Mock Michael F Easleyr Governor William G Ross Jr, Secretary North Carolina Department of Environment and Natural Resources Alan W Klimek, P E Director Division of Water Quality March 17, 2006 Subject Additional Information Request Stormwater discharge permit application Concrete Supply Co — Mocksville Application Number NCG140358 Davie County On September 20, 2005 and again on October 4, 2005, the Division of Water Quality, Stormwater Permitting Unit received portions of your application for a permit to discharge under NPDES General Permit NCG140000, a permit to discharge stormwater and wastewater, from the subject ready mix concrete facility at 215 Industrial Boulevard in Mocksville, North Carolina I apologize for my delay in responding to your submittals Some portions of the submittal are unclear to us, and we are requesting additional information in order to continue processing your application Please submit additional information addressing the items listed below Notice of Intent (NOI) items a Item 13 of the NOI indicates that there are no discharges from the three wastewater sources listed However, based on our phone discussion yesterday, it appears that wastewater from the aggregate bins will leave the site through the remnant sediment pond at the site's southwest corner b Similarly, wastewaters that may be generated in the dry batch plant area appear to be directed to the two swales east and west of the dry batch plant Given the proximity of the batch plant equipment, we preliminarily conclude that wash down and possibly other flows in these swales would be wastewaters If so, then the discharge of wastewaters from the southwest sediment pond is required to meet TSS, settleable solids, and pH permit limits It is not clear to us that either substantiating calculations or explanatory narrative are presented to establish how compliance with the permit limits will be obtained at the discharge from this pond Please provide an engineering argument that predicts compliance with the three permit limits 2 Calculations and Analytical Summary sheet review a The calculations appear to be based on a plant average production figure of 125 CY per day Rather than an average value, is there a reason to consider either a maximum or minimum production day as the critical condition with respect to the likelihood of a discharge from the recycle system? We are interested in the hydraulic capacity of the system under some selected nearly -worst -case scenario b I'm uncertain as to the origin and eventual disposition of the waters contained in the recycle system structure as presented in the calculation sheet Please confirm or correct my understanding of the water balance as I understand it from the calculation sheet Naf Carolina Xturldy North Carolina Division of Water Quality 1617 Mail Service Center Raleigh NC 27699 1617 Phone (919) 733 7058 Customer Service Internet www ncwateruuality ors Location 512 N Salisbury St Raleigh NC 27604 Fax (919) 733 9612 1 877 623 6749 An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper Mr David Mock ok Page 2of3 'r March 17, 2006 i On an average production day, slump adjustment water accounts for 25 gallons per trip reduction in the contained recycle system volume, amounting to 398 gallons per day leaving the system I assume that city water make-up is added to replace the consumed slump adjustment water, and to maintain a rinse water inventory in the recycle system Do I understand this correctly? ii I judge the calculation of Potential Future Rinse Down Water Consumption is not relevant for a normal operating mode design scenario water balance Do I understand correctly that the "potential future" use relates to circumstances in which recycle water would be directed to the dry batch plant as mix water, and this would not be the normal mode of operation? And that the "potential future" circumstances would not be the mode of operation at which the greatest potential for recycle system discharge would occur? iii I note that the four -basin volume is reported as 27,922 gallons and that the 25-year, 24-hour storm will contribute only 18,060 gallons into the basins, based on 5 5" of rain You further reported yesterday that in the event of an even larger accumulation of rainwater, perhaps over a continuous, protracted rain, that you could switch to an operating mode that directed excess water back to the dry batch plant From our review perspective this provision means that you will be able to re-establish the holding capacity in the recycle system relatively quickly after a significant rain event It seems to me that the design scenario described in your submittal and that the operating mode you described verbally yesterday are sufficient for me to concur that the calculations presented indicate that there would not be a discharge from the recycle system in response to the 25-year, 24-hour storm event Do I understand correctly the intended operation and design result of the recycle system? iv Do I understand correctly that there are no physical means constructed to discharge from the recycle system to surface waters? Are there any bottom drains from the recycle system, for example? v Although not represented in the calculations sheet, you described verbally yesterday the operation of the automatic pH control equipment proposed for the recycle system The system features adjustable pH on -off set points and automatic operation to maintain pH within the set point range 3 Layout Plan review a As indicated in 1 a and I b above, wastewaters from the aggregate bins and the dry batch plant will be collected by the two swales that discharge into the front -side ditch and will enter the remnant sediment pond located on the southwest corner of the property Wastewater discharge is via a perforated riser and new and existing piping b The submittal does not include an engineering argument in the form of engineering calculations or in the form of explanatory narrative that predicts compliance with the permit limits for this wastewater discharge To re -iterate item 1 b above, please provide an engineering argument predicting compliance with the three numerical permit limits c Please make minor revisions to the Layout Plan in the area of the recycle system to locate the pH Control system, the transfer pump from the third cell to the fourth cell, the wash water pump, and the approximate routing of the "potential future" return lines to the dry batch plant J� . Mr David Mock �?r 3 of 3 March 17, 2006 4 Do I understand correctly that aggregate irrigation will be accomplished either by city water or by pH -corrected water from the recycle system? 5 Finally, please note that we need three copies of any re -submittal as noted on page 1 of 5 of the revised NOI (revised form attached ) Again, I apologize for the delay on my desk I am committed to working with Concrete Supply Company on a more expedited basis to ensure no further delays at my end Please call me with any questions about your re -submittal Sincerely, Ken Pickle, P E DWQ Stormwater Permitting Unit (919)733-5083x584 cc Winston-Salem Regional Office SPU files DWQ Central Files Paul Rawls, DWQ READY -MIXED CONCRETE VIA Hand Delivery II119A1I11b" Mr Ken Pickle Stormwater and General Permits Unit Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 CONCRETE SUPPLY CO. RE Supplemental NOI information Concrete Supply Co — Mocksville Plant Dear Mr Pickle, Thank you for taking the time to discuss the additional information needed to process our permit application We understand the department has altered is requirements for NOI applications for NCG140000 Stormwater permits seeking substantially more information from the ready mix concrete industry than we have submitted in the past As discussed, we surveyed the wash pit structure last week and submitted the information to the engineering firm that developed the site plan Based upon this survey, they are v developing an as -built site plan that will delineate the wash pit, stormwater drainage flow, and Bmp's implemented to clarify stormwater runoff To expedite our supplemental submittal information, I am in the process of drawing the wash pit with cross section elevations and calculating the design volume Based upon my preliminary review, I am confident that we can meet the 25-year 24-hour storm event criteria with this structure The raw material stockpiles at this facility are not graded to drain into the washpit during a storm event These materials are washed at the quarry and if needed irrigated with city water During a storm event, water from this area is diverted into a sediment basin where it is filtered through a perforated riser surrounded by stone I am confident that pH, TSS and settleable solids will not be an issue from this source of water 3823 Raleigh Street Charlotte N C 28206 2042 1 Post Office Box 5247 Charlotte N C 282991 Telephone (704) 372 29301 FAX (704) 334 8650 "An Equal Opporfumfy Employer" r e f t l I a t 1 t � s � r a j t We anticipate completing the wash pit volume calculations and our revtew of the as -built site plan by October 7 2005 Based on this schedule, i am planning to forward odr r supplemental submittal information to the department on or before October 14, 2007` ` w If you have any que'sttons feel free to contact me at (704) 353-2013 or email davtd mock @ cone rete supplyco com \ 4 1 J ' Sincerely, e \ c > a t r ! 4 1 1 f 4 I £ David G Mock k ` Chief Engineer R r Concrete Supply Co r ` Cc Henry Batten - { Mocksville Plant--{Stormwater File Mr Steve Tedder— Department of Water Quality — Winston-Salem Regional Office 1 t _ i iY r / r I r M n s 1 yi 1 n r N t S 1 I \ k ^ I r ! l f L l ! f � 5 t J .. 14 r y r \ Y I ! f 1 L r ! r t _ ! f f rJ s r t r � � � i � � r r w I -+ � 1 � � r { r � r r � s / _ { I ,r ti i i F � r a I I 1 � µ ! , � �' t r ! � t r F � [ .. s r r} � „ ti r I � t � n � � r i r s � ti -- 1 I " �� � 1 � I { �, � > r � r n � r t » � ! r + r � i I — � ? � ✓ h � Y w1 1 A w 1 l � I + � i t � + r I — � ' � �t � 1 9 ���� I x �. I l � 5 ` { "i ,, , r .. f ' t F � e t -, i r I , � s s r 1 Z � 1 F t � ' � � .� i � r t . ,,. r � + - r � � r a � ; r ti y � w � � � ti r L� 1 + I a r y r 1 � r i i s r � I J � i a 5 � �' } I 5 R s I � s r � h � f � � 9 I � J � r f � r r I r C a r, n � V � t h .. s 1 r � ,. E 3 — 1 y ! l � 4 .ten r � _ t � r � s� = 1 A r e ! R � � ... i ` I ' � ; r � S s .. I a fr { � y 1 4 } r e r � � � ~ f � r � � 1 + f i )A r � 1 � r � t � 5 c L s ' } � � e .- t i Y J I I � r f s r' y r ^ + t ` ' ` r + i y � s v t � � 1 S 1 � � d; t � 1 r h l x } � 3 i r i + � � I e � � 1 t � � 1 f 5 i 1 = f A f , L9 ace Analytical 't www pacelabs cam November 04 2005 Mr David Mock Concrete Supply 3823 Raleigh Street Charlotte NC 28206 RE Lab Project Number 92106336 Client Project ID Stockpile Water Dear Mr Mock Pace Analytical Services Inc 9800 Klncey Avenue Suite 100 Huntersville NC 26078 Phone 704 875 9092 Fax 704 875 9091 Pace 4nalyhcal Services Inc 2225 Riverside Drive Asheville NC 28804 Phone 828 254 7176 Fax 828 252 4618 NOV 17 2005 DENR -_WATER QU LI �n Enclosed are the analytical results for sample(s) received by the laboratory on October 28 2005 Results reported herein conform to the most current NELAC standards where applicable unless otherwise narrated in the body of the report Inorganic Wet Chemistry and Metals Analyses were performed at our Pace Asheville laboratory and Organic testing was performed at our Pace Charlotte laboratory unless otherwise footnoted If you have any questions concerning this report please feel free to contact me Sincerely Kate Knauff Kate Knauff@pacelabs cam Project Manager Enclosures Asheville Certification IDS REPORT OF LABORATORY ANALYSIS NC Wastewater 40 This report shall not be reproduced except in full NC Drinking Water 37712 without the written consent ace ttt of PAnalytical Services Inc SC 99030 y FL NELAP E87648 °neIac Charlotte Certification IDS NC Wastewater 12 NC Drinking Water 37706 Sc 99006 FL NELAP E87627 ace AalytIcal www pacelabs com Lab Sample No 926275876 Client Sample ID WEST 78 GATE Pace Analytical Services Inc 9800 dincey Avenue Suite 100 Huntersville NC 23078 Phone 764 875 9092 Fax 704 875 9091 Pace Analytical Services, Inc 2225 Riverside Drive Asheville NC 28804 Phone 828 254 7176 Fax 828 252 4618 Lab Project Number 92106336 Client Project ID Stockpile Water Project Sample Number 92106336 001 Date Collected 10/28/05 11 30 Matrix Water Date Received 10/28/05 14 45 Parameters Results Units Report L)mit — _ Analyzed By CAS No Dual RegLmt Wet Chemistry PH Method EPA 150 1 PH 7 60 units 10/31/05 18 50 CD1 Total Suspended Solids Method EPA 160 2 Total Suspended Solids —"22 mg/l 3 3 11/02/05 17 10 JMW Total Settleable Solids Method_ EPA Total Settleable Solids �1� 0 10 10/29/05 06 00 TCM Date 11/04/05 Page 1 of 11 Asheville Certification i0s REPORT OF LABORATORY ANALYSIS Charlotte Certification 10s NC Wastewater 40 NC Wastewater 12 NC Drinking Water 37712 This report shall not be reproduced except in fullNG Drinking Water 37746 Sc 9903Q without the written consent of Pace Analytical Services Inc Sc 99006 FL NELAP E87648 RC Cp ,°� a°ati� a, nelac FL NELAP E87627 ace Analytical ° www pacelabs com Lab Sample No 926275918 Client Sample ID WEST 67 GATE Pace Analytical Services, Inc 9800 Kincey Avenue Suite 100 Nuntersville NC 28078 Phone 704 875 9092 Fax 704 875 9091 Pace Analytical Servress Inc 2225 Riverside Drive Asheville NC 28804 Phone 328 254 7176 Fax 828 252 4618 Lab Project Number 92106336 Client Project ID Stockpile Water Project Sample Number 92106336 002 Date Collected 10/28/05 00 00 Matrix Water Date Received 10/28/05 14 45 Parameters Results Units Report Limit Analyzed By CAS No Qual RegLmt Wet Chemistry pH Method EPA 150 1 pH 7 66 units 10/31/05 18 50 CD1 Total Suspended Solids Method EPA 160 2 Total Suspended Solids 38 mg/1 3 3 11/02/05 17 11 JMW r Total Settleable Solids Methad� 160 5 Total Settleable Solids NO ml/1/hr 0 10 10/29/05 06 00 TCM Date 11/04/05 Asheville Certification Ins REPORT OF LABORATORY ANALYSIS NG Wastewater 40 NC Drinking Water 37712 This report shall not be reproduced except in full Sc 37712 without the written consent of Pace Analytical Services Inc 99030 FL NELAP E87648 �c°9 nelac Page 2 of 11 Charlotte Certification IN NC Wastewater 12 NC Drinking Water 37706 SC 99006 FL NELAP E87627 accAnalytical ° www pacelabs cam Lab Sample No 926275926 Client Sample ID SOUTH 67 GATE Pace Analytical Services Inc 9800 Kincey Avenue Suite 100 Huntersville NC 28078 Phone 704 875 9092 Fax 704 875 9091 Pace Analytical Services Inc 2225 Riverside Drive Asheville NC 28804 Phone 828 254 7176 Fax 828 252 4618 Lab Project Number 92106336 Client Project ID Stockpile Water Project Sample Number 92106336 003 Date Collected 10/28/05 12 00 Matrix Water Date Received 10/28/05 14 45 Parameters Results Units Report Limit Analyzed By CAS No Qual RegLmt Wet Chemistry PH Method EPA 150 1 pH r,7-51 un1 s 10/31/05 18 50 CD1 Total Suspended Solids Method EPA 160 2 Total Suspended Solids 34"� mg7� 3 3 11/02/05 17 11 JMW Total Settleable Solids Method -EPA-160T5 Total Settleable Solids �' ND ml/1/hr 0 10 10/29/05 08 00 TCM Date 11/04/05 Asheville Certification IDs REPORT OF LABORATORY ANALYSIS NC Wastewater 40 37712 This report shall not be reproduced except in full NC Drinking Water SC 37712 without the written consent of Pace Analytical Services Inc 99030 FL NELAP E87648 0 49 9 U nelac Page 3 of 11 Charlotte Certification 10 NC Wastewater 12 NC Drinking Water 37706 SC 9900G FL NELAP E87627 aceAnalytical ° www pacelabs cam Lab Sample No 926275934 Client Sample ID SOUTH SAND GATE Pace Analytical Services Inc 9800 Krncey Avenue Suite 100 Nuntersville NC 28078 Phone 704 875 9092 Fax 704 875 9091 Pace Analytical Services Inc 2225 Riverside Drive Asheville NC 28504 Phone 828 254 7176 Fax 828 252 4618 Lab Project Number 92106336 Client Project ID Stockpile Water Project Sample Number 92106336 004 Date Collected 10/28/05 12 00 Matrix Water Date Received 10/28/05 14 45 Parameters Results Units Report Limit Analyzed By CAS No Qual RegLmt Wet Chemistry PH Method EPA 150 1 PH 7"bb units 10/31/05 18 50 CD1 Total Suspended Solids Method EPA 160 2 Total Suspended Solids 16 mg/l 3 3 11/02/05 17 12 JMW Total Settleable Solids Method EPA 160 5 Total Settleable Solids ND— ml//l/T'� 0 10 10/29/05 08 00 TCM Date 11/04/05 Page 4 of 11 Asheville Certification ID s REPORT OF LABORATORY ANALYSIS Charlotte Certification IDs NC Wastewater 40 NC Wastewater 12 NC Drinking Water 37712 This report shall not be reproauced except in full NC Drinking Water 377U6 Sc 99030 without the written consent of Pace Analytical Services Inc Sc 99006 FL NELAP E87648 a�� FL NELAP E87627 n 4a' c ace Analytical ° www pacelabs cam Lab Sample No 926275942 Client Sample 1D NORTH SOLITE Pace Analytical Services Inc 9800 Kincey Avenue Suire 100 Huntersville NG 28078 Phone 704 875 9092 Fax 704 875 9091 Pace Analytical Services Inc 2225 Riverside Drive Asheville NC 28804 Phone 628 254 7176 Fax 828 252 4618 Lab Project Number 92106336 Client Project ID Stockpile Water Project Sample Number 92106336 005 Dace Collected 10/28/05 12 30 Matrix Water Date Received 10/28/05 14 45 Parameters Results Units Report Limit Analyzed By CAS No Qual RegLmt Wet Chemistry pH Method EPA 150 1 pH 781~— units 10/31/05 18 50 CD1 Total Suspended Solids Method EPA 160 2 Total Suspended Solids 13' mg/ ......... 3 3 11/02/05 17 12 3MW Total Settleable Solids Method EPA 160 5 Total Settleable Solids ND"�� ml/l/hr .-...- .m.. 0 10 10/29/05 v— 07 00 TCM Date 11/04/05 Asheville Certification IN REPORT OF LABORATORY ANALYSIS NC Wastewater 40 This report shaft not be reproduced except in full NC Drinking Water 37712 without the written consent of Pace Analytical Services Inc SC 99030 FL NELAP E87648 `nelac Page 5 of 11 Charlotte Certrfiration IN NC Wastewater 12 NC Drinking Water 37706 SC 99006 Ft_ NELAP E87627 IdEmEh aceAnalylcal° www pacelahs cam PARAMETER FOOTNOTES Method 9071E modified to use ASE Pact, Analytical Services, inc 9800 Kincey Avenue Suite 100 Nuntersville NC 28078 Phone 704 875 9092 Fax 704 875 9091 Pace Analytical Services, inc 2225 Riverside Drive Asheville NC 28804 Phone 828 254 7176 Fax 828 252 4618 Lab Project Number 92106336 Client Project ID Stockpile Water All pH Free Chlorine Total Chlorine and Ferrous Iron analyses conducted outside of EPA recommended immediate hold time Depending on the moisture content the PRLs can be elevated for all soil samples reported on a dry weight basis 2 Chloroethyl vinyl ether has been shown to degrade in the presence of acid ND Not detected at or above adjusted reporting limit NC Not Calculable i Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit MDL Adjusted Method Detection Limit Date 11/04/05 Asheville Certification IDs REPORT OF LABORATORY ANALYSIS NC Wastewater 40 This report shall not be reproduced except in full NC Drinking Water 37712 without the written consent of Pace Analytical Services Inc SC 99030 FL NELAP E87648 .4°,0 Y nelac "age 6 of 11 Charlotte Certification Ts NC Wastewater 12 NC Drinking Water 37706 SC 99006 FL NELAP E87627 Pace Analytical Services Inc 9800 K.incey Avenue Suite 100 Huntersville NC 28078 Anal vtICal ® Phone 704 875 9092 Fax 709 875 909 ] www pacelabs com QUALITY CONTROL DATA Pace Analytical Services Inc 2225 Riverside Drive Asheville NC 28804 Phone 828 254 7176 fax 828 252 4613 Lab Project Number 92106336 Client Project ID Stockpile Water QC Batch 141335 Analysis Method EPA 160 5 QC Batch Method EPA 160 5 Analysis Description Total Settleable Solids Associated Lab Samples 926275876 926275918 926275926 926275934 926275942 SAMPLE DUPLICATE% 926279100 926275876 DUP Parameter Units Result Result RPD footnotes Total Settleable Solids ml/l/hr ND ND NC Date 11/04/05 Asheville Certification IDS REPORT OF LABORATORY ANALYSIS NC Wastewater 40 37712 This report shall not be reproduced except in full NC Drinking Water Sc 37712 without the written consent of Pace Analytical Services Inc 99030 FL NELAP E87648 ,'ne�acf Page 7 of 11 Charlotte Certification IDS NO Wastewater 12 NO Drinking Water 37706 5C 99006 FL NELAP E87627 Pace Analytical Services Inc Pace Analytical Services Inc 9800 Ktncey 4venue Suite 100 2225 Riverside Drive Nunrersville NC 28078 Asheville NC 28804 Anal v�ical ® Phone 704 875 9092 Phone 828 254 7176 Fax 704 875 9091 Fax 828 252 4618 wWw pacelabs cam QUALITY CONTROL DATA Lab Project Number 92106336 Client Project ID Stockpile Water QC Batch 141467 Analysis Method EPA 150 1 QC Batch Method EPA 150 1 Analysis Description pH Associated Lacs Samples 926275876 SAMPLE DUPLICATE Parameter Units PH units Date 11/04/05 926265208 DUP Result Result 7 080 7 110 RPD Footnotes 0 Asheville Certification IDs REPORT OF LABORATORY ANALYSIS NC Wastewater 40 37712 This report shalt not be reproduced except in full NC Drinking Water SC 37712 without the written consent of Pace Analytical Services Inc 99030 FL NELAP E87648 n o r� v nelac Page 8 Or 11 Charlotte Certification IDs NC Wastewater 12 NC Drinking Water 37706 Sc 99006 FL NELAP E87627 Pace Analylrcal Services Inc 9800 Kincey Avenue, Suite 100 NuntersvillP NC 28078 Phone 704 875 9092 Analytical Fax 704 875 9091 www pacelabs cam QUALITY CONTROL DATA QC Batch 141468 QC Batch Method EPA 150 1 Associated Lab Samples SAMPLE DUPLICATE 926283094 Pace Analytical Services Inc 2225 Riverside Drive Asheville NC 28804 Phone 828 254 7176 Fax 828 252 4618 Lab Project Number 92106336 Client Project ID Stockpile Water Analysis Method EPA 150 1 Analysis Description pH 926275918 926275926 926275934 926275942 926275918 DUP Parameter Units Result Result RPD Footnotes pH units 7 660 /7 660 0 V Date 11/04/05 Asheville Certification IDs REPORT OF LABORATORY ANALYSIS NC Wastewater 40 This report shall not be reproduced except in full NC Drinking Water 37712 SC 99030 without the written consent of Pace Anafyticai Services Inc O N ACC04D FL NELAP E87648 nelac Page 9 of 11 Charlotte Certification If)s NC Wastewater 12 NC Drinking Water 37706 SC 99006 FL NELAP E87627 Pace Analytical Services Inc Pace Analytical Services, Inc 9800 Kincev Avenue Suite 100 2225 Riverside Drive Huntersville NC 28078 Asheville NC 28804 Anal v�ical o Phone 704 875 9092 Phone 828 254 7776 Fax 704 875 9091 Fax 628 252 4618 www pacelabs cam QUALITY CONTROL DATA Lab Project Number 92106336 Client Project Ill Stockpile Water QC Batch 141671 Analysis Method EPA 160 2 QC Batch Method EPA 160 2 Analysis Description Total Suspended Solids Associated Lab Samples 926275876 926275918 926275926 926275934 926275942 METHOD BLANK 926293762 Associated Lab Samples Parameter Total Suspended Soli 926275876 926275918 926275926 926275934 926275942 Blank Reporting Units Result Limit Footnotes mg/l NO 1 0 LABORATORY CONTROL SAMPLE 926293770 Spike LCS LCS Parameter Um is Conc Result Rec Footnotes Total Suspended Solids mg/l 250 00 248 0 99 r DUPLICATE 926293861 926287731 DUP Parameter Units Result Result RPD Footnotes Total Suspended So ds mg/l 4400 4600 5 ;late 11/04/OS Asheville Certification IDs REPORT OF LABORATORY ANALYSIS NC Wastewater 40 37712 This report shall not be reproduced except in full NC Drinking Water Sc 37712 without the written consent of Pace Analytical Services Inc 99030 FL NELAP E87648 a `� "F �rnelac, Page 10 of 11 Charlotte Certification IDs NC Wastewater 12 NC Drinking Water 37706 Sc 99006 FL NELAP E87627 l ace AnalyticaI ° www pacelabs cam QUALITY CONTROL DATA PARAMETER FOOTNOTES Pace Analytical Services Inc 9800 Kincey Avenue Suite 100 Huntersville NC 28078 Phone 704 875 9092 Fax 704 875 9091 Pace Analytical Services Inc 2225 Riverside Drive Asheville NC 28804 Phone 828 254 7176 Fax 828 252 4618 Lab Project Number 92106336 Client Project ID Stockpile Water Consistent with EPA guidelines unrounded concentrations are displayed and have been used to calculate X Rec and RPD values LCS(D) Laboratory Control Sample (Duplicate) MS(D) Matrix Spike (Duplicate) OUP Sample Duplicate NO Not detected at or above adjusted reporting limit NC Not Calculable J Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit MDL Adjusted Method Detection Limit RPO Relative Percent Difference hate 11/04/05 Asheville Certification !Ds REPORT OF LABORATORY ANALYSIS NC Wastewater 40 37712 This report shall not be reproduced except in full NC Drinking Water SC 37712 without the written consent of Pace Analytical Services Inc 99030 FL NELAP E87648 A Laq 0 1 i,lhnelac z Page 11 of 11 Charlotte Certification IN NG Wastewater 12 NC Drinking Water 37706 SC 99006 FL NELAP E87627 CHAIN -OF -CUSTODY 1 Analytical Request Document The Chain of Custody is a LEGAL DOCUMENT All relevant fields must be completed accurately A.0e7 ar,a Anf)nItn-fi rr Levv, ifre.try Lrvur Page of Section A Section B Section C - Required client Information Required Project information invoice Information Company rF. f I J 1 L ` Report To i s I / f f i l Attention{ +n'f4`NPDES REGULATORY AGE NC Y ❑ GROUNDWATER ❑ DRINKING WATER Address - - Capy To Company Name ❑ UST ❑ RCRA ❑ Other - f _ / Address L]GA OIL ❑IN [EMI ❑MN ;ANC Entail jo f iMoc Pur hase Order No C Pace Quote Reference ❑OH ❑SC [] WI DOTHER Pliant, Fax Prefect Name Pace I'Lolecl Mamper Filtered (YJN) Requested Due DatelTATA s r ' Protect Number Pace Profile # Requested Analysis Valid Matrix Codes Section D Required Client information MATRIX rout= Z Preservatives DRkNKING WATER DW WATERWT a� a af — -� SAMPLE I D WASTE WATER WA,�u o U w P'n S0iL I-SOL D SL " '"DUCT COLI LCTED �' o g "z 4t One Character per box A Z f) 91 Olt OL HnPE ' 2 n< ¢� COMPOSil E S IAR f COMPOSIT E ENRJGRA[3 -- o a ° o O 1 Samples IC}s MUST BE UNIQUE AIR AR OTHER or w c� �' ¢ x O ''4 = rn H zz o " 0 �J t t1 y Pace Project �m Number TISSUE TS DATE TIME DATE TIME j r y z Z i 0 LahID tdr °- r ®t L/ 1 , j� f� ! J fV ■ • ■ACCEPTED BY ■ SAMPLE CONDITION Additional Comments r s t J t z y z T Z } Z Z Z f ti 1 J71 Y j } p t F i l } } } SAMPLERNAME ■ NATURE _C U PRINT Name of SA jVIPLER U v f !t Iri' Ec _ E SIGNATURE of SAMPLER RATE Signed {MM J RP! YYJ Cr o c� w In SEE REVERSE SIDE FOR INSTRUCTIONS .. f r ,, f ti r ALL 0020i nv 3 31 M2r05 CALCULATIONS AND ANALYTICAL SUMMARY ANALYTICAL SUMMARY RAW MATERIAL STOCKPILES PLANT GATE TSS SETTLEABLE SOLIDS FIELD pH LAB pH WEST 78 STONE ND 793 760 WEST 67 STONE 8 ND 765 766 AVERAGE 30 NIA NIA NIA SOUTH 67 STONE 34y, ND 777 751 SOUTH SAND 16 ND 843 766 AVERAGE 25 NIA NIA NIA NORTH SOLITE 13 ND 808 781 MOCKSVILLE PLANT WATER CALCULATIONS WASH DOWN PIT BASIN VOLUMES BASIN 1 = 4270 8 GALLONS BASIN 2 = 5338 5 GALLONS'r BASIN 3 = 8796 5 GALLONS TOTAL VOLGALLONS VOLUME 922 2GALLONS' 2 3 9 R RINSE DOWN WATER RECYCLED AVERAGE PRODUCTIO = 125 CUBIC YARDS/DAY AVERAGE LOAD SIZE = 7 85 CUBIC YARDS $ oafs AVERAGE DAILY TRIPS = (125 CUYD)1 (7 85 CUYDITRIP) = 15 92 1 GALLONS RINSE WATER USED PER TRIP = 150 4b ,ring-r Eu�/s GALLONS RINSE WATER RECYCLED/DAY = (150 GALLONITRIP) x(15.92 TRIPS/DAY) r2388` 'm a pm C � ^ Ut•tLl I uuu J 10 C� E -24" g2t,-arxteo RINSE DOWN WATER CONSUMED 1&I s SLUMP ADJUSTMENT = 25 GALLONSITRIP 1 Cfl! p GALLONS RINSE WATER CONSUMED/DAY = (25 GALLONITRIP) x(1t5-92 TRIPSIDAY) = 398 POTENTIAL FUTURE RINSE DOWN WATER CONSUMPTION ✓AVERAGE PRODUCTION = 125 CUBIC YARDS/DAY GALLONS PER CUBIC YARD IN CONCRETE PRODUCTION = 27 ✓ POTENTIAL GALLONS INTO PRODUCTION/DAY = (125 CUYDIDAY) x ( 27 GALLONSICUYD) = 3375 112 Permit NCG140334 SOC County Davie Region Winston-Salem Compliance Inspection Report Effective 06/27/03 Expiration 07/31/04 Owner Concrete Supply Co Effective Expiration Facility Concrete Supply Co -Davie 218 Cooper Creek Dr Contact Person Steve Makor Title Directions to Facility System Classifications Primary ORC Secondary ORC(s) On -Site Representative(s) 24 hour contact name Johnie Alexander Related Permits Inspection Date 03/30/2011 Entry Time 01 30 PM Primary Inspector Michael M Mickey Secondary Inspector(s) Mocksville NC 27028 Phone 336-751-5133 Certification Exit Time 01 45 PM Phone Phone 704-372-2930 ext 2071 Phone 336-771-5000 Reason for Inspection Routine Inspection Type Compliance Evaluation Permit Inspection Type ROC y Mix Concrete Stormwater/Wastewater Discharge Facility Status ■ Compliant ❑ Not Compliant Question Areas E Storm Water (See attachment summary) Page 1 Permit NCG140334 Owner Facility Concrete Supply Co Inspection Date 03/30/2011 Inspection Type Compliance Evaluation Inspection Summary Permit and Outfalls # Is a copy of the Permit and the Certificate of Coverage available at the site? # Were all outfalls observed during the inspection? # If the facility has representative outfall status is it properly documented by the Division? # Has the facility evaluated all illicit (non stormwater) discharges? Reason for Visit Routine Comment This permit expired 7/31/04 Concrete supply only has one active ready mix facility in Mocksville but holds three NCG14 permits in Davie County NCG140358 is for the existing facility This permit (NCG140334) and NCG140238 need to be voided Sent rescission form by email to Johnie Alexander today Yes No NA NE ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ Page 2 Permit NCG140238 SOC County Davie Region Winston Salem Compliance Inspection Report Effective 08/01/09 Expiration 06/30/11 Owner Concrete Supply Co Effective Expiration Facility Concrete Supply Co-Mocksville 498 Depot St Contact Person Johnie Alexander Title Directions to Facility System Classiflcattons Primary ORC Secondary ORC(s) On -Site Representative(s) 24 hour contact name Johnie Alexander Related Permits Inspection Date 03/30/2011 Entry Time 01 50 PM Primary Inspector Michael M Mickey Secondary Inspector(s) Mocksville NC 27028 Phone 704-372-2930 Certification Exit Time 02 10 PM Phone Phone 704 372-2930 ext 2071 Phone 336-771-5000 Reason for Inspection Routine Inspection Type Compliance Evaluation Permit Inspection Type Ready Mix Concrete Stormwater/Wastewater Discharge COG Facility Status ■ Compliant ❑ Not Compliant Question Areas Storm Water (See attachment summary) Page 1 Permit NCG140238 Owner Facility Concrete Supply Co Inspection Date 03/30/2011 Inspection Type Compliance Evaluation Inspection Summary Permit and Outfalls # Is a copy of the Permit and the Certificate of Coverage available at the site? # Were all outfalls observed during the inspection? # If the facility has representative outfall status is it properly documented by the Division? # Has the facility evaluated all illicit (non stormwater) discharges? Reason for Visit Routine Comment This permit (NCG140238) needs to be voided Concrete Supply only has one existing facility in Davie County and it Is covered by NCG150358 For some reason Concrete Supply holds three NCG 14 permits in Davie County The other one that needs to be voided is NCG140334 Resci ssion forms were emailed to Johnie Alexander today for NCG140238 and NCG140334 so they can be voided Page 2 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO NCG140000 CERTIFICATE OF COVERAGE No NCG140358 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215 1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Concrete Supply Co, LLC is hereby authorized to discharge�tormwater from a facility located at P�ce'93 Wd S�PI.,J 2`�¢ r aim p� KB P Concrete Supply Co — Mocksville Plant 2I5 Industrial Blvd Mocksville Davie County to receiving waters designated as unnamed tributary to Leonard Creek, a class C water in the Yadkin -Pee Dee River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, I1, III, IV, V, and VI of General Permit No NCG 140000 as attached This certificate of coverage shall become effective April 11, 2014 This Certificate of Coverage shall remain in effect for the duration of the General Permit Signed this day April 11, 2014 P for Tracy E Davis, P E , Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission Compliance Inspection Report Permit NCG140358 Effective 07/01/11 Expiration 06/30/16 Owner Concrete Supply Co LLC SOC Effective Expiration Facility Concrete Supply Company Mocksvdle Plant County Davie 215 Industrial Blvd Region Winston Salem Mocksville NC 27028 Contact Person Johnie Alexander Title Phone 704-372 2930 Ext 2071 Directions to Facility System Classifications Primary ORC Certification Phone Secondary ORC(s) On Site Representative(s) Related Permits Inspection Date 05M212016 Entry Time 01 00PM Exit Time 02 30PM Primary Inspector Sherri V Knight Phone 336-776 9696 Secondary Inspector(s) Reason for Inspection Routine Inspection Type Compliance Evaluation Permit Inspection Type Ready Mix Concrete S tormwate rNVastewa ter Discharge COC Facility Status Compliant Not Compliant Question Areas ■ Storm Water (See attachment summary) Page 1 Permit NCG140358 Owner Facility Concrete Supply Co LLC Inspection Date 0511212016 Inspection Type Compliance Evaluation Reason for Visit Routine Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ■ ❑ ❑ ❑ # Has the facility conducted Its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ N ❑ Comment Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed during the inspection? ® ❑ ❑ Cl # If the facility has representative oulfall status is it properly documented by the Division? ❑ ❑ ■ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ! ❑ ❑ ❑ Comment Recommended to remove tree growing from the riser pipe Inside the stormwater basin on site Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi annually? ❑ ❑ ❑ Comment The facility had not had a qualifying discharge at time of Inspection Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ■ ❑ ❑ ❑ # Does the Plan include a Narrative Description of Practices ? E ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? E ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ■ ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ■ ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ® ❑ ❑ ❑ # Does the Plan include a BMP summary? E ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ® ❑ ❑ ❑ # Does the facility provide and document Employee Training> ■ ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? M ❑ ❑ ❑ # Is the Plan reviewed and updated annually? E ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ■ ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ® ❑ ❑ ❑ Comment Page 3