Loading...
HomeMy WebLinkAboutNCG140309_COMPLETE FILE - HISTORICAL_20150422STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. // DOC TYPE 1�- HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ �(�� ,�j C�¢ 22- YYYYM M DD PIMA i�l NCDENR North.Carolina Department of Environment and Natural Resources Pat McCrory Governor April 22, 2015 Southern Concrete Materials,' Inc. ATTN: Mr. Jeff Lamm 80 Pond Road Asheville, North Carolina 28806 Southern Concrete Materials, Inc. ATTN: Mr. Jeff Lamm PO Box 5395 Asheville, North Carolina 28813 Donald R, van der Vaart Secretary SUBJECT: NPDES Stormwater Permit Compliance Inspection Southern Concrete Materials, Inc. -- 80 Pond Road General Permit No: NCG140000; COC No: NCG140309 Buncombe County Dear Mr.' Lamm: In -,response to a complaint about stormwater runoff from your facility, and an inspection of noncompliance on March 2, 2015, NCDENR-Land Quality Section staff conducted a follow-up si#e inspection on April 8, 2015. The primary goal of this inspection was to evaluate compliance with the conditions of the NCG140000 General Permit, and to discuss any actions that have been or could -be taken to assure compliance with your permit NCG140309. At the time of this inspection the facility was found to be in compliance with your permit. Please refer to the enclosed Compliance Inspection Report for additional comments, observations, and recommendations made during the inspection. There are some matters that require your attention to keep the site in compliance. 1. You were provided an Authorization to Construct a wastewater collection system and we encourage you to proceed with these plans. You indicated that a closed - loop recycle system is planned for this facility in the near future. Note that to be defined as a truly closed -loop system with no monitoring requirements; the system will have to meet the requirements of 15A NCAC 02T .1003 "Permitting by Regulation." This requires that there is sufficient storage capacity to contain the runoff from a 24-hour, 25-year storm event plus one foot freeboard; and that the facility develops and maintains a spill control plan in the event of a Division of Energy, Mineral, and Land Resources — Land Quality Section Asheville Regional Office, 2090 US Highway 70, Swannanoa, North Carolina, 28778-8211 Telephone 828-296-4500 Fax 828-299-7043 ne http://portal.ncdgnr.org/web/Inland-qualms l , opf Carolina An Equal Opportunity / Affirmative Action Employer Vaturally Mr. Jeff Lamm April 22, 2015 Page 2 of 2 wastewater release. Please contact Ms. Beverly Price of the Division of Water Resources, Asheville Region at (828) 296-4500 if you have any questions or need more. information regarding the "27' requirements for this system. Please provide our office a schedule for installation of this system. 2. Develop a routine maintenance schedule for keeping accumulated silt off of Pond Road and out of the drainage ditch in front of your facility. During this follow-up compliance inspection it was determined that the settling basins and its outflow channel had been maintained, seeded and matted; a secondary berm had been provided near the road to direct stormwater flows to the settling basins; and monthly sampling of the stormwater and wastewater outfall has been initiated. Please retain and append this letter to your Stormwater Pollution Prevention Plan (SPPP) or permit. If you have any questions or comments concerning this letter, please contact Darlene Kucken or me at (828) 2964500. Sincerely, /,-,. 4. Laura Herbert, PE Regional Engineer Enclosure (April 8, 2015 Inspection Report) ec: Bethany Georgoulias, RCO Landon Davidson, ARO - DWR Carl Solesbee (brickit270@bellsouth.net ) Permit: NCG140309 SOC: County: Buncombe Region: Asheville Contact Person: Jeff Lamm Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Compliance Insuectlon Report Effective: 07/01/11 Expiration: 06/30/16. Owner: Southern Concrete Materials Inc Effective: Expiration: Facility: Southern Concrete Materials -Asheville 80 Pond Rd Asheville NC 28808 Title: Phone: 828-253.6421 .Certification: Phone: Inspection Date; 04/08/2015 Entry Time: 10:OQAM • Exit Tlme: 12:10PM Primary Inspector: Darlene J Kucken Phone: Secondary Inspector(a): Reason for Inspection: Follow-up Inspection Type: Compliance Evaluation Permit Inspection Type: Ready Mix Concrete Stormwater/Wastewater Discharge COC Facility Status: Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Page: 1 permit: NCG140309 Owner - Facility: Southern Concrete Matarlats Inc Inspection Data: 0410W015 Inspection Type : Compliance Evaluation Reason for Melt: Follow-up Inspection Summary: This inspection was conducted as a follow-up inspection to the March 2, 2015 stormwater permit compliance Inspection. The site was found to be in noncompliance during that inspection primarily due to the lack of maintenance of the settling basins, the need for additional bean protection near the front of the site to direct stormwater flow to the settling basins, and failure to provide quarterly monitoring of the wastewater discharge componenet of the site. During this follow-up inspection, it was noted that these Issues were addressed. The facil€ty was asked to provide a maintenance plan for keeping silt off of Pond Road by scraping current deposition from the road and ditch, and then providing regular maintenance with a vacuum sweeper. It was noted that both SCM and other entities contribute to the deposited silt along Pond Road and that when the road is repaired by DOT the ditchline needs to be reworked to provide for better positive flow and drainage. Page: 2 permit: NCG140309 Owner- Facility, Southem Concrete Materials Inc Inspection Date: 04/0812015 Inspection Type : Compiiance Evaluation Reason for Visit: Follow-up Stormwater Pollution PreventlonPlan Does the site have a Stormwater Pollution Prevention Plan? # Does the Plan include a General Location (USGS) map? # Does the Plan Include a "Narrative Description of Practices"? # Does the Plan Indude a detailed site map including outfall locations and drainage areas? # Does the Plan Include a list of significant spills occurring during the past 3 years? # Has the facility evaluated feasible alternatives to current practices? # Does the facility provide all necessary secondary containment? # Does the Plan Include a BMP summary? # Does the Plan include a Spill Prevention and Response Plan (SPRP)? # Does the Plan Include a Preventative Maintenance and Good Housekeeping Plan? # Does the facility provide and document Employee Training? # Does the Plan include a list of Responsible Party(s)? # Is the Pion reviewed and updated annually? # Does the Plan Include a Stormwater Facility Inspection Program? Has the Stormwater Pollution Prevention Plan been implemented? Comment: Settling basins were cleaned out and seeding and matting provided. (Qualitative Monitoring Has the facility conducted Its Qualitative Monitoring semi-annually? Comment: Analytical Monitoring Has the facility conducted its Analytical monitoring? Yee No NA NE ®❑ ❑ ❑ ❑ ❑ ❑ ❑❑M❑ ❑❑❑ ❑❑❑ ❑ ❑ ❑ ❑1❑ ❑ ❑❑❑ M❑❑❑ ■❑❑i1 ■❑❑❑ ❑❑❑ ❑ ❑ ❑ ree No NA NE ■ ❑❑❑ Yes No NA NE ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ELJ Comment: The first of monthly analytical monitoring was provided for the wastewater component of the facility, Monthly monitodna is required for six months and then monitodng will bg guarterltilf_ parameters are not exceeded. Permlt and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? . ❑ ❑ ❑ # Were all outfalls observed during the inspection? N ❑ ❑ ❑ # If the facility has representative outfall status, is it property documented by the Division? ❑ ❑ E ❑ # Has the facility evaluated all illicit (non Stormwater) discharges? ❑ ❑ ❑ Comment: Page: 3 ATA NWENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary March 9, 2015 CERTIFIED MAIL — 7014 0510 0000 4466 6907 CERTIFIED MAIL -- 7014 0510 0000 4466 6891 RETURN RECEIPT REQUESTED Southern Concrete Materials, .Inc. ATTN: Mr. Jeff Lamm 80 Pond Road Asheville, North Carolina 28806 Southern Concrete Materials, Inc. ATTN: Mr. Jeff Lamm PO Box 5395 Asheville, North Carolina 28813 SUBJECT: NPDES Stormwater Permit compliance Inspection Southern Concrete Materials, Inc. — 80 Pond Road General Permit No: NCG140000; COC No: NCG140309 Buncombe County. Dear Mr. Lamm: In response to a complaint about sormwater runoff from your facility, NCDENR-Land Quality Section staff conducted a site Inspection on March 2, 2015., The primary goal of this inspection was to evaluate compliance with the conditions of the NCG140000 General Permit, and to discuss any actions that have been or could be taken to assure compliance with your permit NCG140309. At the time of this inspection the facility was found to be in non-compliance with your permit. There are several issues that need to be addressed. Please refer to the enclosed Compliance Inspection Report for additional comments, observations, and recommendations made during the inspection. In addition, there are some matters that require your immediate attention to bring the site into compliance. 1. You must immediately clean out and maintain your stormwatertwastewater settling basins to make them fully functional, as well as providing maintenance of the ditched channel outlet from these basins. Current lack of maintenance has contributed to stream bank erosion due to excessive outflows from these basins. Division of Energy, Mineral, and Land Resources — Land Quality Section Asheville Regional Office, 2090 US Highway 70, Swannanoe, North Carolina, 28778-8211 Telephone 828-296-4500 Fax 828-299-7043 rie h :! Rortal.nedenr,omtwet>nriland-Qualltv W Ca o �' a An Equal Opportunity 1 Affirmative Action Employer Q�iQIl� Mr. Jeff Lamm March 9, 2015 Page 2 of 2 2. There is an area at the front comer of the property near the road that you are directed to provide a berm or some other means of redirecting stormwater flows to the settling basins. Currently this area is flowing to the outer berm and is contributing to stream bank erosion. 3. You were provided an Authorization to Construct a wastewater collection system and we encourage you to proceed with these plans. You indicated that a closed - loop recycle system is planned for this facility in the' near future. Note that to be defined as a truly closed -loop system with no monitoring requirements, the system will have to meet the requirements of 15A NCAC 02T .1003 "Permitting by Regulation." This requires that there is sufficient storage capacity to contain the runoff from a 24-hour,. 25-year storm event plus one foot freeboard; and that the facility develops and maintains a spill control plan in the event of a wastewater release. Please_ contact Ms. Beverly Price of the Division of Water Resources, Asheville Region at (828) 296-4500 if you have any questions or need more information regarding the "2T" requirements for this system. Please provide our office a schedule for installation of this system. 4. Given that you currently have co -mingled wastewater and stormwater, you are required to conduct quarterly wastewater monitoring of the outfall(s) of these materials per your permit. Since your analytical sampling has not been conducted at this frequency, your permit triggers you to now conduct monthly sampling for a period of at least six months and report these results to this office pursuant to Part IV, Section D of Permit No. NCG140000. A follow-up compliance inspection will be conducted in approximately 30 days to assure the settling basins and its outflow channel have been maintained; a secondary berm has been provided near the road; and monthly sampling of the stormwater and wastewater outfall has been initiated. Please retain and append this letter to your Stormwater Pollution Prevention Plan (SPPP) or permit. if you have any questions or comments concerning this letter, please contact Darlene Kucken or me at (828) 296-4500. Sincerely, eatra 4fa llft� Herbert, PE Regional Engineer Enclosure (March 2, 2015 Inspection Report) ea Bethany Georgoulias, RCO Landon Davidson, ARO - DWR Carl Solesbee (brickit270@bellsouth.net ) Permit: NCG140309 SOC: County: Buncombe Region: Ashevtlie Contact Person: Jeff Lamm Directions to Facility: System Clessi lcationa: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Compliance Inspection Report Effective: 07/01/11 Explratlon: 05/30/16 Owner : Southern Concrete Materials Inc Effective: Explmtlon: Facility: Southern Concrete Materials -Asheville 80 Pond Rd Inspection Date: 03102/2015 Primary Inspector. Darlene J Kucken Secondary tnapector(s): Asheville NC 2UN title: Phone: 828-253-0421 Certification: Phone: EntryTime: 10:00AM Exit Time: 11:30AM Phone: Laura C Herber Phone: Reason for Inspection: Routine Inepection Type: Compllance Evaluation Permit Inspection Type: Ready Mix Concrete StommaterNVastewater Discharge COC Facility Status: Compliant Not Compliant Question Areas: Storm Water (See attachment summary) Page: 1 Permit NC014030n Owner - Feclftty: Strutllern Conaete Materiels lnc lnspeadon Dets: 0310 OIS Inspedlon Type: Compliance Evaluation Reason for Malt: Routine Inspection Summary: 1. The SWPPP is reasonably good, however more consistent updates and organization might be helpful. 2. The settling basins are clearly In need of malntenance and repairs. Because they no longer function at full holding capacity, overflows are more frequent than they need to be and overflows are contributing to streambank erosion. 3. The area currently storing some sandy materials near the front of the property needs to have a berm or some other measure installed to force stormwater flows from this area to the settling basins. Currently, flows from this area are contributing to the streambank erosion because they bypass the settling basin. 4. An Authority to Construct a wastewater collection system was provided in July 2009. This system has not been built. Therefore, the facility currently has co -mingled stormwater and wastewater going to the earthen pits and detention basins. The co -mingled flows of truck wash water plus rainfall are regutated under the wastewater portion of the permit (see Part IV, Section D). Therefore, quarterly monitoring is required. Quarterly monitoring has not been conducted. Under Part IV, Section D, page 10, the lack of quarterly monitoring triggers monthly monitoring for a period of six months. 5. pH buffers were expired; pH buffers need to be kept current 7. There is no vehicle maintenance on site; however there is one 10,000 gallon doub"alled diesel tank on site. We recommend providing a spill kit at the diesel tank in case of any leaks or spills. Page: 2 perMit N00140309 owner • Facility:5outhem Concrete Materiele Inc Inspection Data: 031=015 Inspection Type: Compliance Evaluation Reason for Visit: Routine Storrnwater PgIlUtlon Prevention Plan Does the site have a Stormwster Pollution Prevention Plan? # Does the Plan include a General Location (USGS) map? # Does the Plan indUde a 'Narrative Description of Practices? # Does the Plan Include a detailed site map including outfall locations and drainage areas? # Does the Plan include a list of significant spills occurring during the past 3 years? # Has the facility evaluated feasible altematives to current practices? # Does the faciiity, provide all necessary secondary containment? # Does the Plan Include a 8MP summary? # Does the Plan Include a Spill Prevention and Response Plan (SPRP)? # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? # Does the facility provide end document Employee Training? # Does the Plan include a list of Responsible Party(s)? # Is the Plan reviewed and updated annually? # Does the Plan include a Slormwatar Facility Inspection Program? Has the Stormwater Pollution Prevention Plan been Implemented? 7�s NA N E 0❑❑❑ B ❑ ❑ ❑ ®❑ ❑ ❑ * ❑ 1111 ❑ ❑ 0 ❑ ®❑Ell] ®❑❑❑ ®❑ ❑ ❑ M ❑ ❑ ❑ ®❑❑❑ ®❑❑❑ ®❑❑❑ ®❑ ❑ ❑ ❑M❑❑ Comment: Setdino basins have n t been maintained: lack of maintenance results in excessive overflows which are eroding the streambank. Qualitative Monitoring Has the facility conducted its Qualitative Monitoring semi-annualty? Yes No NA NE ®❑❑❑ Comment: Although qualitative monitgrinn has been conducted, maintenance on existing settling basins has not been undertaken. Anatytical Monitoring Yee No NA NE Has the facility conducted its Analytical monitoring? ❑ ®❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: The facility has been conductino its analytical monitorincl Der the stormwater permit, however. uarteriy monitoring of the wastewater component of the facility has not been undertaken. Permit and O tfa ! Yes No Na N # Is a copy of the Permit and the Certificate of Coverage available at the site? ® ❑ ❑ ❑ # Were all outfalls observed during the inspection? ®❑ ❑ ❑ At It the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ # Has the facility evaluated all illicit (non storrawater) discharges? ❑ ❑ N ❑ Comment: There is one outfall at the facility: the basins associated with this outfall have nlatbeen maintained. Page; 3 North Carolina Beverly Eaves Perdue Governor j ( Mr. Jeff Lamm h Southern Concrete Materials POB 5395 Asheville, NC 28813 At 5404< '=�A 114 NENR Department of Environment and Natural Resources---------'.7 Division of Water Quality Coleen H. Sullins 'Dee -,Freeman fr Director Flilu E � lYl E Secretary July 22, 2009 2 2009 WATER QUALITY SECTION SNEVILLE REGIONAL OFFICE Subject: Authorization td'Coiistr6et"`���.�' __' 4Southern Concrete Materials — Pond Rd COC No. NCG140309 Buncombe County Dear Mr. Lamm: By this letter DWQ is issuing an Authorization to Construct (ATC) wastewater collection, treatment, and recycle facilities at your plant located at 80 Pond Road in Asheville, North Carolina. You are authorized to construct and install the facilities as described in your narrative and calculations submitted, and as shown on the approved drawings attached to this letter; including the specific elements: A truck rinse and drum and chute washout pad; Three, 20'x 56'x 6' deep settling chambers to receive truck rinse water, washout waters, any incidental aggregate storage drainage, pit sludge drainage, and stormwater generated from the small contributing drainage area; 1 • A pit sludge drying area; 0� • A carbon dioxide pH correction system; • A pump and necessary piping to both return treated wastewater to the mix, and to �9 reuse treated wastewater for truck rinse and drum and chute washout; 4 • A runoff diversion structure in front of pits #2 and #3; • And all incidental mechanical, electrical, and structural construction and equipment installation necessary to accomplish a wastewater collection, treatment, and recycle system functioning as implied by the approved submittal package. We are issuing this ATC based on your specific, stated design basis that the facilities will not discharge wastewaters at the design storm (i.e. the 25-year, 24-hour rainfall). We note that your current COC #NCG140309 authorizes only the discharge of stormwaters, not wastewaters. This ATC does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other federal or local governmental permit that may be required, Please notify DWQ's Asheville Regional Office, telephone number (828) 296-4500, at least forty-eight (48) hours in advance of operation of the installed facilities so that an in - place inspection can be made. Such notification to the regional supervisor shall be made Wetlands and aiormwater Branch One 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Noi.- Ci1CQlin a Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-6300 S FAX: 919-807-64941 Customer Service: 1-877-623-6748 /,/� u!'a�`�/ Internet: www,ncwaterquality.org v i/ An Equal Opponunity 1, Affirmative Action Employer ,Mr. Jeff Lamm Southern Concrete Materials NCG140309 July 22, 2009 OF' '64, during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this authorized facility, a certification must be received from the designing professional engineer certifying that the wastewater collection, treatment, and recycle facility has been installed in accordance with the NPDES Permit, this Authorization to Construct, and the approved plans and specifications. Please mail the certification (attached) to the Stormwater Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Please note that any future construction, installation, or modification of wastewater treatment facilities (including process wastewater recycle systems) will require an additional Authorization to Construct (ATC) .prior to construction per 15A NCAC 2H .0138 & .0139. You must submit, in triplicate, plans/specifications and design calculations, stamped and sealed by a professional engineer, with a letter requesting an ATC to the Stormwater Permitting Unit, 1617 Mail Service Center, Raleigh, NC .27699-1617.] Please note that we are returning your check for $100, since the permit processing and annual administering and compliance monitoring fees are strictly associated with coverage under the General Permit, NCG140000 which you already have. There is no additional fee for the ATC. One (1) set of approved plans and specifications is being forwarded to you. Please maintain a copy of the approved plans and specifications on file for the life of the facility. if you have any questions concerning this permit or Authorization to Construct, please contact Ken Pickle at telephone number (919) 807-6376. Sincerely, � PCZA, for Coleen H. Sullins cc: Asheville Regional Office, w/ 1 set approved submittal DWQ Central Files, NCG140309 Stormwater Permitting Unit Files, NCG140309, w/ 1 set approved submittal Enclosures: 1 set approved submittal Southern Concrete Materials check #11694 for $100 Mr. Jeff Lamm Southern Concrete Materials NCG140309 July 22, 2009 Engineer's Certification fCOC No. NCG140309) as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project: wastewater additions at Southern Concrete Materials, 80 Pond Road, Asheville, NC, for the permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following installations: • Construction of a process wastewater collection, treatment, and recycle system at the Southern Concrete Materials Pond Road plant in Asheville, NC. I certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. Signature Date Registration No. Mail this Certification to: Stormwater Permitting Unit NC Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617, October 30, 2008 Mr. Ken Pickle, Environmental E NC DENR — Stormwater Permitting 1617 Mail Service Center Raleigh, North Carolina 27669-161 Re: Permit Application for Authorization -to -Construct (A to C) a Proposed Process / Stormwater Recycling System for Pond Road Concrete Plant Southern Concrete Materials 80 Pond Road Asheville, North Carolina 28806 CPEES Project No. 1114-004 NPDES General Permit No.: NCG140000 Certificate of Coverage: NCG 140309 Dear Mr. Pickles: Southern Concrete Materials (SCM) is pleased to submit the attached Authorization -to -Construct (A to C) permit request report along with construction drawings for the Proposed Process / Stormwater Recycling System for Southern Concrete Materials — Pond Road Concrete Plant located in Asheville, North Carolina; The A to C Report includes: 4 '• NC DENR NPDES General Permit .Application­NCG140000; • Check for $100 made payable to NC DENR; • Site map showing the delineation of drainage area contributing to the process wastewater; + Site layout map showing the proposed location of the process 1 stormwater recycling system; • 25 yr 24-hr stormwater runoff calculations; • Detailed design, construction drawings along with construction specifications for the proposed process and stormwater recycling system; • Site Location Map; • NC Certified laboratory supplied analytical results for stormwater samples collected at similar plant; • Manufacturer supplied literature for the proposed Carbon Dioxide System for pN adjustment. r Y . i SCM sincerely appreciates your cooperation and progress of this project. Please call me at 828- 253-6421 or Mr. Chuck Pakala of CPEES at 704-541-4042 if you have any questions or comments on this permit request. Respectfully submitted, `; Jeff Lamm EH&S Manager Attachments: A to C Permit Application Package Mr. James Combest Southern Concrete Materials PO Box 5395 Asheville, NC 28813 Michael F. Easley, Governor William G. Ross Jr„ Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality September 22, 2006 Subject: NPDES General Permit NCG140000 Certificate of Coverage NCG140309 Southern Concrete Materials Formerly Hyder Concrete, Inc. Buncombe County Dear Mr. Combest: Division personnel have reviewed and approved your request to transfer coverage under the General Permit, received on September 6, 2006. Please find enclosed the revised Certificate of Coverage. The terms and conditions contained in the General Permit remain unchanged and in full effect. This revised Certificate of Coverage is issued under the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency. If you have any questions, please contact the Stormwater Permitting Unit at (919) 733-5083, extension 502. Sincerely, ORIGINAL SIGNED BY KEN PICKLE Alan W. Klimek P. E. cc: DWQ Central files Asheville Regional Office, Water Quality Section Sforrnwaret Permitting Unit, No Carolina �turally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service Internet: h2o.enr.state.mus 512 N. Salisbury St. Raleigh, NC 27604 FAX (919) 733-2496 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycled110% Post Consumer Paper I STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140309 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, SOUTHERN CONCRETE MATERIALS is hereby authorized to discharge stormwater from a facility located at SOUTHERN CONCRETE MATERIALS-ASHEVILLE 80 POND ROAD ASHEVILLE BUNCOMBE COUNTY to receiving waters designated as Hominy Creek, a class C waters, in the French Broad River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, II, III, IV, V, and VI of General Permit No. NCG I40000 as attached. This certificate of coverage shall become effective September 22, 2006. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day September 22, 2006. ORIGINAL SIGNED gy KEN PICKLE Alan W. Klimek, Director Division of Water Quality By Authority of the Environmental Management Commission copyrngnt (c) 1997, maptecn, Inc. ova �%-Drl ' • Division of Water Quality !Wafer Quality Section NGDENRNational Pollutant Discharge Elimination System cteck#Arnirt C �NCG140000 R3'=`r A�4wIzd w NQiICE OF INTEW National Pdlutart DischanI Binination System apptication for coveraW eair_ier Coal Pert -tit N03140000: (Please print or type) 1) Mailing address of om-oer/operator: Nart-6 Hyder Concrete Company Street Actress 2 Country Spring Drive aty Asheville Stye Tdeoxxr e �b. 828/ 254-7333 F x 2) Location of facility producing discharge: Facility N; Hyder Concrete C Facility Gatact Brownie Hyder Street Address 80 Pond Road aty Asheville County Buncombe Tel ephone No. Fa)c strial CEassifrcation Coder/ MAY -) 2CW NCIZ!p;7Fs3(28t80'4.►. 828/ 281-3604 .-... A6&ess to which all pemvt corresponderce vtiil be rrzJl-2rd 3) Pl-ryslcal Location tnfornotion: Gn See NC Zip Code 28804 Please prcide a narrative description d how to get to the facility (use street na -es' stale road nuTbers, anc distanceand cir�ticnfrornaroIir>fc ion). Exi-L 140 south onto Brevard Road , .5 turn right onto Pond Road - Site is on le-ft, east side of I-26. (A ocpy or a county rrep or L3SGS quad sheet with fatality dearly IioCat0d an the rrx is requred to to sut rYitted with this milt cn) 4) This [P'DES PI Application applies to Mich of the foilaI a N--w or Proposed Facility Date operation is to begin ❑ Exsting March 2001 Provide tt-e 4 digit Starxard indt..rstlial Classification Code (SIC Code) that describes the prirrrary irKilstrid activity of this facility SC Code: . 3 2 7 3 6) Provide a brief description of the types of industrial activities and products prockxs ed at this facility (Include a site process diag•arn with this submittal): Produce Readv Mix Concrete - See attached site plan. Hyder Concrece Company, 80 Pond Road, Asheville, NC NCG140000 N-0.1. 7) Discharge points/ Fiecdving vzders: t-bw n-ay discharge points (ditches, pipes, channels, etc.) convey stomw Eder frcrn the properV? ` VU-%ai is the name of the body or bodes of water (creek, scream river, lake, etc) that the facility stornwnater discharges end up in? Hominy Creek If the site stormter dsdhar ges to a separate storm sewer system name the operator of the separate storm sevver system (e.g. City of Raleigh m rhicipal storm sesAer). Receiving water classification (if knov\n): C Tr at las be approved by U-k-- UC Dept- of Errvircinirrer" Healtfi If DEH does not Mprove, awe -age under NM 40000 cannot be granted. No new cE scf-orges of process vv3stev�oter are pern-itted in receiving viaters classified as VVS4 or freshwater ORW 8) Does this facHity have any other NFUES permits? 1I r1b ❑ Yes If yes, list the pen -nit run -hers for all a.rrent NPDES permits for this facility. _ 9) Does this facility have any Non -Discharge perrrrits (e)c recycle permfts)? a r"b ❑ Yes If yes, list the peaTit rxsrtx)ss for all current Ncn-Disd-urge pm its for this facility. 10) Does this facility erTpioy arty best manaagen-e-rt Practices for stom water control? K$ r�.b ❑ yes If yes, Terse briefly d ec ibe: 11) Does this facility have a Storrruuater Pollution Prevention Plan? JUF\b ❑ Yes If yes, v t)e vas it irrpierre"ed? 12) Are vehicle maintenance activities occuring at this facility? ET`Nb ❑ Yes 13) Are discharges occurring from any of the following process wastewater generating activities? Vehi d e and ec ppn-rat dean ng ❑{ Yes ❑ I\b V1ttting c( raw material stockpiles El: Yes Cl rib M)dng drum clearing - E}. Yes ❑ f\b If yes to any of the above, please describe the type crf process used to treaf aracYor recycle the pr ooess v,astewafer. Give design specifics (i.e. design vdurrv, retention time, surface area, etc). [Use separate sheet(s)] Note: C xisb rction of any wastewater treatrner rt facilities require su#xrission of three (3) sets of plans and specifications along with this aappiicatiorti Design of ftxoh E tt facilities rrtist corrrply with regtrirernents 15A NCAC 2H .0138. HYDER CONCRETE COMPANY 80 POND ROAD ASHEVrLLE, NC 1/22/2001 13} All discharges occurring from vehicle and equipment washing, raw material stockpile wetting, and mixing drum cleaning will be routed to the retention ponds. See attached Erosion Control Plan and Erosion Control Drawing. Hyder. Concrete Company, 80 Pond Road, Asheville, NC NCG140000 N.O.I. 14) Does tale facility use a recycle systenY? U fib ❑ Yes If yes, does the system overflow only during rainfall events exceeding the 10-yr, 24^hr rainfall event? ❑ Yes ❑ Nc • • •- • . r. • �r • . • •.• r • ••• �ru • a) is this fad Iity a F-iazardous Waste Treatment, Storage, or Dspy Fad Iity? U fib ❑ Yes b) Is tfis fad Iity a Eck r l CLontity Generator (less than 1000 kg of hazardous waste generated per calendar year) of hazardous vjaste? rib ❑ Yes c) Is this facility a Large Qontity Generator (1000 kg or more of hazardous vvaste generated per calendar year) of hazardous vvaste? U fib ❑ Yes d) If you ansmered yes to questions b. ore., please provide the fdlor�Ang information: Types) of veste: i a,v is material stored-. W-e—e is material stored Ho v marry disposal ship -rents per year: f"hrr e of trarisport / disposal Vendor:_ Vendor address.- 16) Certification: North Carolina Genf Statute 143-21a6 b (i) p-wides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document filed or required to be maintained under Article 21 of regulations of the Environmental Management Commission inOernen6ng that Article, or wino falsifies, tampers with or knowingly renders inaccurate any recording or morwtoring device or med)od required to be operated or maintained under Article 21 or regulations of the Envirormentaf Management C mrnission implementing that Artide, shall be guilty of a misdemeanor punishable by a fine rrot to exceed $10,00 , or by imprisonrnent not to exceed six months, or by both. (18 U.S.C. section 5001 provides a punishment by a fine of not more than $10,000 or imprisonment not more than 5 years, or both, for a similar offense.) I hereby repic st coverage under the referenced General Perm t I wand tt>at coverage Lr der this pern'i t will o_-stitute the pa rit recuirements for the discharge(s) and is enforceable in the same manr>er as an i r d, id-d perz7i t. certify that i am familiar with the infotmaiion contained in this apoicaficn and that to the best of my k noWedge and belief st tcfz infca-nattion is true, oorrplete, and acaurate. Printed Names of Person Sging: Brownie Hyder Title: Owner (SgWure OfAp iiCal t) (Gate SDF- r v State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director April 6, 2001 Ms. Brownie Hyder Hvdcr Concrete Company 2 Country Spring Drive Asheville, NC 28804 lkf:?W,A IT 0 0 NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: General Permit No. NCG140000 Hyder Concrete, Company COC NCG 140309. Buncombe County Dear Ms. Hyder: In accordance with your application for a discharge permit received on Febraary 6,,2001-- we are forwarding herewith the subject certificate'of coverage to-discharge.underthe stafiject state NPDES'general;permit: This permit is issued pursuant to the iequiremerits of North Carolina ; ' General'Statute 143-215-.•Land the Memorandum of.Agreerr►enf betw666 North Car'olira andtthe' US Environmental Protection agency dated Deceiriber 6,`-1983. If any parts;measitrement frequencies or s'ampIing requirements contained iri this permit are unacceptable to you, you have the right to request an individual permit by submitting,an individual permit application., Unless such demand is made,'this certificate of coverage shall be final and binding. Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or ariy1other~17ederal or Local governmental permit that may be required. I,` ' ,i If you have any questions concerning this permit, please contact Aisha Lau at telephone number (919) 733-5083 ext. 578. cc: Asheville Regional Office Central Files Stormwater and General Permits Unit Files 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal Opportunity Affirmative Action Employer Sincer'e�I ..., G�i�-e1 "r��S , Kerr T. Stevens Telephone 919-733-5083 FAX 919-733-9919 50% recycled/ 10% post -consumer Iwaper ,>J STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140309 STORMWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT -DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management. Commission, and.the ; Federal Water.Pollution Control Act, as amended, f Hyder Concrete Company 's �4 Cs hereby authorized to diklharge;stbrmwater.and treated wash , a,A from -a facility located -at s:+ 'id j .Hyde�:COncrele Company l r � x 80 Poi d H6ad : Asheville ti c �: �k k !i f� a r i Buncomhe'County C% r '=to,receiving"waters design5ted'as Hominy Creek`Class'C' waters in the French Broad River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, II,1I1, IV, V, and VI of General Permit No. NCG140000 as attached. This certificate of coverage shall become effective April 6, 2001, This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day April 6, 2001- Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission I Me 01— DA ArwI MOW— W; Ile IV r4t L6 our p um Copyright (C) 1997, Maptech, Inc. 0 Markers Name: NCG140309 - Hyder Concrete Company Short Name: 140309 Coordinates: 0350 32' 43.1" N, 082' 36' 11.2" W 04 Comment: County: Buncombe, Map #: E8SE, Subbasin: 03-%-02, Receiving Stream: Hominy Creek, Class: C.