Loading...
HomeMy WebLinkAboutNCG080653_COMPLETE FILE - HISTORICAL_20170328STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /v C&0 s 0�b,> DOC TYPE [P/HISTORICALFILE ❑ MONITORING REPORTS DOC DATE ❑ (nOI { U3 �O YYYYMMDD t �r` GREENSBORO !FORTH CAROLIHA WATER RESOURCES March 28, 2017 Chuck Manuel, Terminal Manager USF Holland. 201 Stage Coach Trail Greensboro, NC 27409 RE: Industrial Compliance Inspection Inspection location: USF Holland 201 Stage Coach Trail SW Permit #: NCGO80653 Dear Mr, Manuel: On March 22, 2017 the City of Greensboro Stormwater Management Division completed an industrial compliance inspection of USF Holland. Local regulations permit an inspection of industrial facilities under authority granted by City of Greensboro Code of Ordinance Chapter 30, Article 12, Section 7.1 (C-5). This inspection consisted of two parts: a review of the facility files/records and an on -site facility inspection. The inspection was performed by Sherri Scalcione, Ian Dunn and Zack Mackenzie. The following deficiencies/observations were noted during the inspection. Stormwater Pollution Prevention Flan/Spill Plait Review Update the SWP3 plan annually, it is suggested that the review date and signature appear as either an attachment page after the cover or on the cover page itself. Please refer to the permit Part 11, Section A, item number 7 for the full description of the information the plan requires updates to annually. Site Maps and SWP3 • Once verified with the State all outfalls should be noted on the plan. See notes below regarding monitoring deficiencies. Spill Prevention and Response Plan • No deficiencies observed. PO BOX 1170 • GREENSBORO NC 27402-1170 • WWW.GREENSBORO-NC.GOV • 336-373-CITY (2489) Mr, Chuck Manuel USi' Rolland NPDES Compliance Inspection letter Dated 3/28/i7 Page 2 of 2 Monitoring • Monitoring has not been completed since 2013. Mr. Manuel states they have contracted GEOS Environmental to get in compliance with this portion of the permit. • The map used for the previous inspection in 2012 has 2 outfalls marked. Mr. Manuel indicated the plan is to sample outfall #l, please coordinate with the State to ensure all outfalls are monitored as required by the permit. Employee Training • No deficiencies observed Site Inspection Preventative Maintenance/Good Housekeeping • No deficiencies observed. Nun-Stormwater Discharges • Mr. Manual stated that the lift station pump went out in January and last week the float malfunctioned resulting in overflows. In addition to these events, the City has record of this occurring in 2002 and again in 2010 during routine inspections of the dry detention basin. Please contact Ron Boone with the State to ensure that USF Holland is in compliance with the 02T rules (see email dated 3/23/17 for additional details). Be advised that failure to report overflows wiff result in a notice of violation from both the City of Greensboro and NCDEQ. It is recommended that USF Holland take appropriate actions to correct the noted deficiencies. If you have any questions concerning this inspection, please contact me at 336-412-6202 or Sherri. Scalcione@greensboro-nc.gov. Sincerely, C-At A — Sherri Scalcione, Water Quality Specialist City of Greensboro, Water Resources Department cc: Peter Schneider, Water Quality Supervisor Glen White, N.C. Dept. of Environment Quality Industrial Inspection File uItl cnOS PO BOX 1170 - GREENSBORO NC 27402-1170 • WWW.GREENS BORO-NC.GOV • 336-373-CITY (2489) Compliance Inspection Report Permit: NCG080653 Effective: 11/01/12 Expiration: 10/31/17 Owner: Usf SOC: Effective: Expiration: Facility: USF Holland Inc - Greensboro County: Guilford 201 Stage Coach Trl ' Region: Winston-Salem Greensboro NC 27409 Contact Person: Jean Godwin Title: Phone: 330-364-2324 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 03/22/2017 Primary Inspector: Glen White Secondary Inspector(s): Certification: Phone: Entry Time 10:OOAM Exit Time: 11:00AM Phone: 336-776-9800 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Transportation wNehicie Maintenance/Petroleum Bulk/Oil Water Separator Stormwater Discharge COC Facility Status: ❑ Compliant Not Compliant Question Areas: ■ Storm Water (See attachment summary) Page: 1 permit: NCGO80653 Owner - Facility: Usf Inspection Date: 03122/2017 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: Inspection conducted by Sherri Scalcione, Ian Dunn & Zack MacKenzie of Greensboro Water Resources Department on March 22, 2017. Deficiencies were found. Outfalls not properly identified and no monitoring has been performed. See COG inspection letter in WSRO hard files for full letter text. Glen White NCDEQ - DEMLR Page: 2 Permit: NCGO80653 Owner - FaclIIty:Usf Inspection Date: 03I22I2017 Inspection Type; Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? E ❑ ❑ ❑ # Does the Plan include a General Location (LISGS) map? ®❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? 0 ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ®❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ 0 ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ®❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑ # Does the Plan include a BMP summary? ®❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? B ❑ ❑ ❑ #Does the Plan includea Preventative Maintenance and Good Housekeeping Plan? ®❑ ❑ ❑ # Does the facility provide and document Employee Training? 0 ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? N ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ! ❑ ❑ ❑ Comment: Siteplan needs to be updated with outfall information once verified. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ®❑ ❑ Comment: Monitoring not conducted. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ 0 ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ 0 ❑ ❑ Comment: No analytical monitoring is being conducted. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ ❑ ❑ ❑ # Were all outfails observed during the inspection? ❑ M ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ■ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ E ❑ ❑ Comment: Outfalls not properly identified and no monitoring is being conducted according to the permit. Page: 3 Permit: NCGO80653 SOC: Compliance Inspection Report Effective: 11/01/07 Expiration: 10/31/12 Effective: Expiration: County: Guilford Region: Winston-Salem Contact Person:QeanGodw,�i)nDirections to Fac System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Title: Inspection Date: 06/27/2008 Entry Time: 11:30 AM Primary Inspector: William C Basinger Secondary Inspector(s): Certification: Owner: USF Holland Inc Facility: USF Holland Inc - Greensboro 201 Stage Coach Tri Greensboro NG 27409 Phone: 330-384-2324 Exit Time: 12:30 AM Phone: Phone:336-771-5000 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Transportation wNehicle Maintenance/Petroleum Bulk/Oil Water Separator Stormwater Discharge COC Facility Status: ❑ Compliant Not Compliant Question Areas: U Storm Water (See attachment summary) Page: 1 f Permit: NCGO80653 Owner - Facility: USF Holland Inc Inspection Date: 06/27/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? Zr n n n # Does the Plan include a General Location (USGS) map? en n n # Does the Plan include a "Narrative Description of Practices"? zr❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? J' 1 n ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? RT ❑ ❑ n # Has the facility evaluated feasible alternatives to current practices? JAG ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? 'PT ❑ n n # Does the Plan include a BMP summary? ,[i1' n ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ,� ❑ ❑ ❑ # Does the facility provide and document Employee Training? # Does the Plan include a list of Responsible Party(s)? ❑ ❑ ❑ # Is the Plan reviewed and updated annually? Z ❑ n n # Does the Plan include a Stormwater Facility Inspection Program? ,EI ❑ n n Has the Stormwater Pollution Prevention Plan been implemented? I n n n Comment: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ Cl ❑ Comment: Analytical Monitoring Yes No NA NE' Has the facility conducted its Analytical monitoring? 2r n ❑ n # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? kr ❑ ❑ ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? fi ❑ ❑ ❑ # Were all outfalls observed during the inspection? `f�l ❑ ❑ n # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? IN ❑ ❑ ❑ Comment: Page: 3 NORTH CAROLINA .DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES FAX TRANSMITTAL Water Quality Section Winston-Salem Regional Office 585 Waughtown Street Winston-Salem, N.C. 27107 Phone: (336)771-5000 Fax: (336)771-4630 TO: der 4 S'a FAX NUMBER: FROM: (mike.mickevancdenr.Rov) DATE:`�— Number of pages (including cover page): COMMENTS: tJcw' \�� Nl I I NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Govemor Stephen Wonch USF Holland Inc - Greensboro 750 E 40th St Holland, MI 49423 Dear Permiee: Division of Water Quality Charles Wakild, P.E. Director March 5, 2012 Subject: NPDES Stormwater Permit Coverage Renewal USF Holland Inc - Greensboro COC Number NCGO80653 Guilford County Dee Freeman Secretary Your facility is currently covered for stormwater discharge under General Permit NCGO80000. This permit expires on 10/31/2012. The Division staff is currently in the process of renewing this permit. When a draft is available for notice and public comment, it will be posted on our website at http://portal.ncdenr.org/web/wq/ws/su/public-notices. Please continue to check this website to review and comment on proposed changes to the permit. Once the permit is reissued, your facility would be eligible for continued coverage under the reissued permit. To assure consideration for continued coverage under the general permit, you must apply to the Division of Water Quality (DWQ) for renewal of your permit. Enclosed you will find a Permit Coverage Renewal Application Form. The application must be completed and returned by May 4, 2012. Letters confirming our receipt of the completed application will not be sent. Failure to request renewal within the time period specified may result in a civil assessment of at least $250.00. Larger penalties may be assessed depending on the delinquency of the request. Discharge of stormwater from your facility without coverage under a valid stormwater NPDES permit would constitute a violation of NCGS 143-215.1 and could result in assessments of civil penalties of up to $25,000 per day. "No exposure exclusion" is now available to industrial facilities in any of the categories of "storm water discharges associated with industrial activity," (except construction activities). If you feel your facility can certify a condition of "no exposure", i.e. the facility industrial materials and operations are not exposed to stormwater, you can apply for the no exposure exclusion. For additional information contact the Central Office Stormwater Staff member listed below or check the Stormwater Permitting Unit Web Site at http://portal.ncdenr.org/web/wq/ws/su/npdessw#tab-5. If the subject stormwater discharge to waters of the state has been terminated, please complete the enclosed Rescission Request Form. Mailing instructions can be found on the bottom of the form. You will be notified when the rescission process has been completed. If you have any questions regarding the permit renewal procedures please contact Robert Patterson of the Central Office Stormwater Permitting Unit at (919) 807-6375. Sincerely, -ley Bradley Bennett Supervisor, Stormwater Permitting Unit 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 location: 512 N. Salisbury Si. Raleigh, North Carolina 27604 Phone: 91 M07-6300 4 FAX: 919.807-64941 Customer Service: 1-877-623.6748 Internet: www.nrwaterquality.org An Equal Opportunity 4 Atrirmative Action Employer None hCarolina Naturally &WAT`t,� Permit Coverage Renewal Application Form National Pollutant Discharge Elimination System Certificate of Coverage Number Stormwater General Permit NCG080000 NCGO>30653 The following is the information currently in our database for your facility. Please review this information carefully and make all corrections/ additions as necessary in the space provided to the right of the current information, Owner Affiliation Information Owner / Organization Name: Owner Contact: Mailing Address: Phone Number: Fax Number: E-mail address: * Reissued Permit will 6e mailed to the owner address USF Holland Inc Stephen Wonch 750 E 40th St Holland, MI 49423 616-395-5000 Ext. 616-395-5057 Facility/Permit Contact Information Facility Name: USF Holland Inc - Greensboro Facility Physical Address: 201 Stage Coach Trl Greensboro, NC 27409 Facility Contact: Leon Daniels Mailing Address: 201 Stage Coach Trl Greensboro,NC 27409 Phone Number: 336-851-1680 Ext, Fax Number: 336-855-7025 E-mail address: leon.daniels@USFC.com Aischarne Information Receiving Stream: Stream Class: Basin: Sub -Basin: Number of Outfalls Horsepen Creek W S-III; NSW Cape Fear River Basin 03-06-02 Impaired Waters/TMDL Does this facility discharge to waters listed as impaired or waters with a finalized TMDL? ❑ Yes ❑ No J Don't Know for information on these waters refer to 17dp y/hlo.enr state.nc.us/su/Impaired Waters TMDL/ CERTIFICATION I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete and accurate. Signature Print or type name of person signing above Date Title SW General Permit Coverage Renewal Please return this completed renewal application form to: Stormwater Permitting Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 February 8, 2012 Bobby Coffey USF Holland 201 Stage Coach Trail Greensboro, NC 27409 RE: Industrial Compliance Inspection Inspection location: USF Holland 201 Stage Coach Trail SW Permit #: NCG080653 Dear Mr. Coffey: On February 7, 2012 the City of Greensboro Stormwater Management Division completed an industrial compliance inspection of the USF Holland. Local regulations permit an inspection of industrial facilities under authority granted by City of Greensboro Code of Ordinance Chapter 30, Article 12, Section 7.1 (C-5). This inspection consisted of two parts: a review of the facility files/records and an on -site facility inspection. The inspection was performed by Sherri Scalcione, and the following deficiencies/observations were noted during the inspection. Stormwater Pollution Prevention Plan/Spill Plan Review Site Maps and SWP3 ♦ No deficiencies observed. Spill Prevention and Response Plan ♦ No deficiencies observed. Monitoring ♦ No deficiencies observed. Employee Training ♦ Keep updated training records with the SWPPP plan. Site Inspection Preventative Maintenance/Good Housekeeping ♦ No deficiencies observed. Non-Stormwater Discharges ♦ No deficiencies observed. It is recommended that USF Holland take appropriate actions to correct the noted deficiencies. If you have any questions concerning this inspection, please contact me at 336-412-6202 or Sherri.Scaleione@greensboro-nc.gov. Sincerely, Sherri Scalcione, Water Quality Specialist City of Greensboro, Water Resources Department cc: Peter Schneider, Water Quality Supervisor Mike Mickey, N.C. Dept. of Environment and Natural Resources Jean Godwin, USF Holland Chuck Hoffman, Mid -Atlantic Associates, Inc. Industrial Inspection File & \NATFR Michael F. Easley, Governor 0 State of North Carolina "'iiliam G. Ross, Jr., Secretary Department of Environment and Natural Resources > Coleen H. Sullins., Director Division of Water Ouality 30 June 2008 Mr. Barry Coffey, Terminal Manager USF Holland 201 Stage Coach Trail Greensboro, NC 27406 Subject: NPDES Stormwater Permit Permit No. NCG080653 Representative Outfall Status Request USF Holland Guilford County Dear Mr. Coffey: . The Winston-Salem Regional Office staff have reviewed your request dated April 30, 2008 for a determination that stormwater discharge outfall (SDO) 001 be granted representative outfall status for stormwater outfall 002. Based on the information and maps provided and a site visit on Friday, June 27, 2008, we are approving this request. In accordance with 40 CFR §122.21(g)(7); you are authorized to sample outfall number 001 as a representative outfall. This approval is effective with the next sampling event. We also want to remind you that the permit still requires Qualitative Monitoring be performed at all SDOs, regardless of representative status. Please remember that any actions you initiate in response to benchmark exceedences as directed in the tiered response provisions of your permit must address all drainage areas represented by SDO 001, where appropriate. Please append this letter to your Stormwater Pollution Prevention Plan (SPPP) to document that representative outfall status has been approved. If changes in drainage areas, structures, processes, . storage practices, or other activities occur that significantly alter the basis of this approval, you should reapply to this Office for the Representative Outfall Status based on the updated information. If you have any questions or comments concerning this letter, please contact me at (336).771-5000 or at corey.basinger0ancmail.net. Sincerely, ' W. Corey Basinger Environmental Engineer cc: Winston-Salem Regional Office Central Office/Stormwater Permitting Unit Central Files-SWP NorthCarolina ,11 atura!!f North Carolina Division of Rater Quality 585 Waughtown Street, Winston-Salem, NC 27107 Phone (336) 771-5000 Customer Service Internet: www.ncwaterquatity.org Fax (336) 771-4630 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled110% Post Consumer Paper & WAT`C^ Michael F. Easley, Governor O� QG State of North Carolina William G. Ross, Jr., Secretary Department of Environment and Natural Resources 0 Coleen H. Sullins., Director _. Division of Water Qualit 30 June 2008 5 Li Mr. Barry Coffey, Terminal Manager USF Holland 201 Stage Coach Trail Greensboro, NC 27406 Subject: NPDES Stormwater Permit PPrwu R fes Permit No. NCG08 53 epresentative outfall Status Request USF Holland Guilford County Dear Mr. Coffey: The Winston-Salem Regional Office staff have reviewed your request dated April 30, 2008 for a determination that stormwater discharge outfall (SDO) 001 be granted representative outfall status for stormwater outfall 002. Based on the information and maps provided and a site visit on Friday, June 27, 2008, we are approving this request. In accordance with 40 CFR §122.21(g)(7), you are authorized to sample outfall number 001 as a representative outfall. This approval is effective with the next sampling event. We also want to remind you that the permit still requires Qualitative Monitoring be performed at all SDOs, regardless of representative status. Please remember that any actions you initiate in response to benchmark exceedences as directed in the tiered response provisions of your permit must address all drainage areas represented by SDO 001, There appropriate. Please append this letter to your Stormwater Pollution Prevention Plan (SPPP) to document that representative outfall status has been approved. if changes in drainage areas, structures, processes, storage practices, or other activities occur that significantly alter the basis of this approval, you should reapply to this Office for the Representative Outfall Status based on the updated information. If you have any questions or comments concerning this letter, please contact me at (336) 771-5000 or at core�,.basinger@ncmail.net. Sincerely, W. Corey Basinger Environmental Engineer cc: Winston-Salem Regional Office Central Office/Stormwater Permitting Unit Central Files-SIVP North Carolina Division of Water Quality 585 Waughtown Street, Winston-Salem, NC 27107 Phone (336) 771-5000 Internet %vN,%s,.ncwatergualitv.org Fax (336)771-4630 0 �Q g co 4 AJt c .A afur Customer Semite 1-S77-623-6748 An Equal CpportunitylAfBrrnative Action Employer — 50% Recydedf10% Post Consumer Paper � o�0� war�9Q� 01W7 Mr. Bane Coffey, Terminal Manager USF Holland 201 Stage Coach Trail Greensboro, NC 27406 SUBJECT: Compliance Evaluation Inspection USF Holland NPDES Permit No. NCGO80653 Guilford County Dear. ;Vlr. Coffey: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources 30 June 2008 Coleen H. Sullins, Director Division of water Quality A Compliance Evaluation Inspection was performed on the USF Holland general stormwater permit (NCG080653) on Friday, June 27, 2008 by Corey Basinger of the Winston-Salem Regional Office. Mr. Darin McClure, PE was also present for the inspection.. The inspection consisted of two parts: an on -site inspection of the facility and an in -office file review. The following are the findings from the subject inspection. 1. Permit The NPDES general stormwater permit (NCG080653) became effective on November 1, 2007 and expires on October 31, 2012. It. Records/Reports The Stonnwater Pollution Prevention Plan (SPPP) was prepared by Mid -Atlantic Associates, Inc. and appeared complete and well organized. A review of the reports revealed no discrepancies. A copy of the data is kept on file. All applicable data is collected as per the NPDES general permit requirements. Ili. Facility Site Review The subject facility discharges stormwater pursuant to NPDES Permit NCG080653. The facility also discharges wastewater from an oilAvater separator to the City of Greensboro sanitary Sewer system. IV. Effluent & Receiving Waters USF Holland discharges to an unnamed tributary to I-lorsepen Creek in the Cape Fear River Basin. V. Self -Monitoring Program USF Holland conducted the required qualitative and quantitative monitoring since 2007 when the SPPP was written. VI. Operations and Maintenance The following items must be addressed: 1) the oilJwater separator must be unclogged to ensure proper operation and to prevent an illegal discharge to surface waters; 2) pallets should be stored under roof or be covered at all times; 3) it is suggested that curbs be added at all open bay doors at the maintenance shop and truck wash station. N6"°hCarolina Xalurally North Carolina Division of Water Quality 585 Waughtown Street Phone (336) 771-5000 Customer Service Winston-Salem Regional Office Winston-Salem, NC 27107 Fax (336) 771-4630 1-877-623-6748 Intemet: www.ncwaterquatily.org An Equal Opportunity/Affirmative Action Employer — 50% Recycfed110% Post Consumer Paper I. VI1. Other Please contact this Office when the above items have been completed. If you should have any questions or concerns regarding this report, please contact Corey Basinger at (336) 771-5000. Sincerely, Steve W. Tedder Water Quality Supervisor Cc: Darin McClure, PE (N id -Atlantic Associates, Inc., 409 Rogers View Court, Raleigh, i�TC 27610) Guilford County Health Dept. Central Files, WSRO Form Approved ��. OLtB No.2040-0057 Approval Expires 8-31-98 United States Environmental Protection Aeencv- Washington. D.C.- 20460 Section A: National Data System Coding Transaction Code NPDES No. YrIMo/Day Inspection Type Inspector FacilityType N 5 NCG060653 08-06-27 C S 2 Facility Evaluation Rating BI QA ..........Reserved........... 4 N N Section B: Facility Data Name and Location of Facility Inspected: Entry Time: Permit Effective USF Holland 1 125 hrs. Date: Nov. 1, 2007 Located at 20I Stage Coach Trail in Greensboro, NC Exit Time: Permit Expiration 1240 hrs. Date: Oct. 31, 2012 Name(s) of On -Site Representative(s): Tille(s): Phone No(s): Mr. Barry Coffey Terminal Manager 336-851-1680 Mr. Darin McClure, PE Consultant 919-250-9918 Name, Address of Responsible Official: Title: Terminal Manager Mr. Barry Coffey Phone No. 336-851-1680 Contacted? Yes USF Holland 201 Stage Coach Trail Greensboro, NC 27409 Section C: Areas Evaluated During Inspection (check only those areas evaluated) X Permit X Flow Measurement X Operations/Maintenance NA Sewer Overflow X Records/Reports X Self -Monitoring Program NA Sludge Handling/Disposal NA Pollution Prevention X Facility Site Review NA Compliance Schedules NA Pretreatment X Effluent/Receiving Waters NA Laboratory X Stormwater Section D: Summary of Findings/Comments See attached letter for further details regarding the subject inspection. Name s) and Sign ture(s} of Inspectors: Agency/Offce/Telephone: Date: DVtiTQ I VVSRO / (336)771-5000 Signature of Re fewer: Agency/Office: Date: DWQ / WSRO I (336)771-5000 al— 30 -ao EPA Form 3560-3 (Rev 9-94) i Permit: NCG080653 Owner - Facility: USF Holland Inc Inspection Date: 06127/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ® n n n # Does the Plan include a General Location (USGS) map? ® n n n # Does the Plan include a "Narrative Description of Practices"? ® ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ® ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ■ ❑ n n # Has the facility evaluated feasible alternatives to current practices? ®n n n # Does the facility provide all necessary secondary containment? ®❑ n n # Does the Plan include a BMP summary? ® ❑ ❑ n # Dees the Plan include a Spilf Prevention and Response Plan (SPRP)? ® Cl n n # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ®.❑ ❑ ❑ # Does the facility provide and document Employee Training? ®n n n # Does the Plan include a list of Responsible Party(s)? ® ❑ n ❑ # Is the Plan reviewed and updated annually? n n n # Does the Plan include a Stormwater Facility Inspection Program? ® ❑ ❑ n Has the Stormwater Pollution Prevention Plan been implemented? ® n n n Comment: 1) verify discharge from OIW separator to City, (2) move pallets under roof, (3) unclog OAN separator drain in truck wash area, (4) suggest adding curbs at open bay doors on shop Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ®❑ n n Comment: Analytical Monitorin Yes No NA NE Has the facility conducted its Analytical monitoring? ® n hl n # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ® ❑ ❑ n Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? M ❑ n n # Were all outfalls observed during the inspection? n ❑ n n # If the facility has representative outfall status, is it properly documented by the Divis+on? ❑ ❑ ® ❑ # Has the facility evaluated all illicit (non Stormwater) discharges? ®❑ n n Page: 3 Permit: NCGO80653 Owner- Facility: USF Holland Inc Inspection Date: 06/27/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Comment: Representative Outfall Status granted based on site visit. Documentation to follow. Page: 4 MID -ATLANTIC A S S 0 C I AT E S, I N C. Engineering & Environmental Solutions 409 Rogers Vic it, Cmirt / RuleighI Norrlr Caralina I27610 800 -486 -7568 / 919-250-99181919-250-9950 Facsimile sru�».muannli�re.camr April 30, 2008 North Carolina Department of Environment and Natural Resources Division of Water Quality Stormwater and General Permits Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Subject: REQUEST FOR REPRESENTATIVE OUTFALL STATUS USF HOLLAND 201 STAGE COACH TRAIL GREENSBORO, NORTH CAROLINA MID -ATLANTIC PROJECT NO. 00OR1222.07 To Whom It May Concern: On behalf of USF Holland and YRC Worldwide Enterprise Services, Inc-, Mid -Atlantic Associates, Inc. requests representative outfall status for the above referenced site. The facility is permitted to discharge stormwater under the North Carolina Department of Environment and Natural Resources, Division of Water Quality, General Permit NCG080000. Stormwater currently discharges off site at two outfalls (See Attached Drawing 2.1). Potential pollutants associated with stormwater_ discharges at each outfall include oils, greases, petroleum, vehicle fluids, and suspended solids- Based on our recent evaluation of the site and its stormwater outfalls, it appears that the stormwater discharge from Outfall 1 is representative of discharges from each outfall at the site. It also appears that the discharge at Outfall 1 would be the "worst -case" discharge of the two. We appreciate your consideration of this request. If you -have any questions, please feel free to contact me at 919-250-9918. Sincerelv, MID -ATLANTIC ASSOCIATES, INC. Wayne andolph Senior Project Manager Attachment:.. Drawing cc: Ms. ,lean Goodwin, YRC Worldwide Enterprise Services, Inc. 1222.07/2-26-08/Request for Representative Ou1fall Status/WEWaso N RETENTION DU SCRAP tLwIO-AST OUTFALL If1 ASPHALT TRMRISERDUMP TRUCK MAINTENANCE -GALLON TRUCK OIL AST , C� AIR COMPRESSOR PARKING GALLON I EMPLOYEE EW OIL �+ PARKING `� 5-GALLON DRUM STORAGE ASPHALT I 1 1 1 " 1 1 1 DUM 1 FREIGHT LOADING BUILDING ' 1 -cLzLrzaa+' za.�- ++a_E GRASS BUILDING 1 ASPHALT TRUCK PARKING I I DUMPSTER ASPHALT GRASS GRASS MINOR ♦ OUTFACEz DRAINAGE FEATURE MINOR DRAINAGE i FEATURE 1 ti v LEGEND y SPILL/DRAINAGE FLOW DIRECTION MONITORING WELL LOCATION ® STORM DRAIN/DROP INLET —c c—c— CABLE LINE a 100' -X X—%— FENCE (CHAIN LINK) - - _ - _ - - . DRAINAGE AREA BOUNDARY 1 — — PROPERTY BOUNDARY DRAINAGE AREA BOUNDARY 2 APPROXIMATE SCALE: 1 "= 100' _. DRAWN BY: `5 DATE: MAY 2008 " SITE MAP DRAFT J0B 00OR1222.09 -ATLANTIC USF HOLLAND MIII ASSOCIATES, INC. 201 . STAGE COACH TRAIL CHECK: &vp7� NO: Engineering & EnvrronmentalSolutions GREENSBORO, NORTH "CAROLINA HECK: ��'1 Na 01-1222o1-os APPROVAL: DOWG 21 REFERENCE: MID -ATLANTIC FIELD NOTES. MID -ATLANTIC A S S 0 C I A T E S. I N C. Engineering & Environmental Solutions 409 Rogers View Court 1 Raleigh / North Carolina 127610 800-486-75681919-250-99181919-250-9950 Facsimile www.maaonline.com April 30, 2008 �-� ---------------- W� Care 'si rt � RECEI.VED— N.C. Not of ENft JU 0 5 2008 ' i�utcn•Salem egiaoaf office North Carolina Department of Environment and Natural Resources % Division of Water Quality I Stormwater and General Permits Unit `:� 1617 Mail Service Center Raleigh, North Carolina 27699-1617� as .r+, Subject: REQUEST FOR REPRESENTATIVE OUTFALL STATUS USF HOLLAND _ 201 STAGE COACH TRAIL GREENSBORO, NORTH CAROLINA MID -ATLANTIC PROJECT NO. 00OR1222.07 To Whom It May Concern: On behalf of USF Holland and YRC Worldwide Enterprise Services, Inc., Mid -Atlantic Associates, Inc. requests representative outfall status for the above referenced site- The facility is permitted to discharge stormwater under the North Carolina Department of Environment and Natural Resources, Division of Water Quality, General Permit NCGO80000. Stormwater currently discharges off site at two outfalls (See Attached Drawing 2.1). Potential pollutants associated with stormwater discharges at each .o.utfall include oils, greases, petroleum, vehicle fluids, and suspended solids. Based on our recent evaluation of the site and its stormwater outfalls, it appears that the stormwater discharge from Outfall 1 is representative of discharges from each outfall at the site. It also appears that the discharge at Outfall 1 would be the "worst -case" discharge of the two. We appreciate your consideration of this request. If you have any questions, please feel free to contact me at 919-250-9918. S=.ncereN MID -ATLANTIC ASSOCIATES, INC. /14k%-1 Wayne andolph Senior Project Manager Attachment: Drawing cc: Ms. Jean Goodwin, YRC Worldwide Enterprise Services, Inc. 1222.0712-26-08/Request for Representative Outfall. Status/VVER/aso L"Lw Quo i, -Y Wxrw — I 1 RETENTION OUTFALL !1 TRASH RISER DUMPSTER SCRAP METAL DUMPSTER` , TRUCK MAINTENANCE 250-GALLON p WASTE OIL AST AIR COMPRESSOR , DO -GALLON I NEW OIL ♦ AST I ,, ♦ 5-GALLON %,DRUM STORAGE ASPHALT ♦ � I � 4 1 01 TRUCK PARKING 4 R R ASPHALT R EMPLOYEE PARKING { i 1 - 1 DUM FREIGHT LOADING BUILDINGi PST% I �— --Mar __- �r SL�� �� BUILDING GRASS I 1 ASPHALT I TRUCK PARKING I DUMPSTER ASPHALT V�K x—x 7i-`—`—I �I ���T--^�� � n n GRASS MINOR ® DRAINAGE OUTFACE g2 FEATURE MINOR DRAINAGE FEATURE I ti a LEGEND y SPILL/DRAINAGE FLOW DIRECTION 0 MONITORING WELL LOCATION STORM DRAIN/DROP INLET 0 100' —c C c— CABLE LINE —x I x— FENCE (CHAIN LINK) - - - - - - - - DRAINAGE AREA BOUNDARY 1 — — PROPERTY BOUNDARY DRAINAGE AREA BOUNDARY 2 APPROXIMATE SCALE: 1'- 100' DRAWN6Y: DATE: MAY 2008 SITE MAP DRAFT JOB OOOR1222.09 ID -ATLANTIC USF HOLLAND m ASSOCIATES, INC. 201 STAGE COACH TRAIL CHECK: wg7L, NO: Engineering & Environmental Solutions GREENSBORO, NORTH CAROLINA ENG HECK. CA 01-122201-09 APPROVAL: DOWG 21 11 REFERENCE: MID —ATLANTIC FIELD NOTES. 11 Approving Representative Outfall Status - Transition to Regions Subject: Approving Representative Outfall Status - Transition to Regions From: Bethany Georgoulias <Bethany.Georgoulias@ncmailnet> Date: Wed, 04 Jun 2008 09:10:55 -0400 To: Al Hodge <Al.Hodge@ncmaiLnet>, Ed Beck <Ed.Beck@ncmailnet>, Belinda Henson <Belinda.Henson@ncmaiLnet>, Danny Smith <Danny.Smith@ncmailnet>, Steve. Tedder@NCmai Lnet, Roger Edwards <Roger,Edwards @ncmaiLnet>, Rob Krebs <rob.krebs@ncmailnet> CC: Bradley Bennett <bradley.bennett@ncmailnet>, Bill Diuguid <Bi11.Diuguid@ncmailnet>, Mike Randall <mike.randall@ncmaiLnet>, Ken Pickle <ken.pickle@ncmaiLnet>, Kelly Johnson <Kelly.P.Johnson@ncmailnet>, robert.patterson@ncmaiLnet, Jennifer Jones <jenniferJones@ncmailnet>, bridget.munger@ncmailnet, John Hennessy <John.Hennessy@NCMail.net>, Niki Maher <niki.maher@ncmailnet>, Shelton Sullivan <Shelton.Sul Iivan@ncmailnet>, katie.merritt@ncmaiLnet Regional Supervisors, At our last East/West Consistency Meetings, we asked the regions what they thought about reviewing and approving/denying requests for Representative Outfall Status (ROS). Up to now, we have handled these in the Central Office. The responses were very positive, and we felt it was an appropriate transition because usually we rely on a site visit by the region to verify conditions at the site support representative outfall status. We have set up a process for tracking requests and approvals, and with this e-mail we are providing guidance for your staff to handle these requests. We plan to provide additional guidance at future Consistency Meetings or other meeting opportunities, but we wanted to get something out to you in the interim (which is why it's -noted as "draft.") -- especially since we are already working with regional staff on some ROS requests. The tracking process is in the last part of the attached memo, but here's a summary of what -regional -staff should do: 1. Copy the ROS request letter (and site plan if submitted) to the Central Office/SPU. 2. Update RIMS under the Events Tab with the date for "Representative Outfall Status Requested." 3.•A template letter of ROS approval is attached. Please feel free to modify it as necessary. 4. If you deny the ROS request, list specifically the basis for denial. if the denial is temporary, note the conditions that need to be corrected before a re -visit and granting of ROS. S. Be sure to remind the permittee that qualitative monitoring (visual and odor characterization of the discharge) is still required _at all outfalls_. Also remind the permittee that a tiered response (if required by their permit) must be implemented in the other represented sub -drainage areas. 6. Copy the final ROS approval or denial letter to (1) Central Office/SPU and (2) DWQ Central Files. 7. Update BIMS under the Events Tab with date for "Representative Outfall Status Approved.' Be sure to _include information in the Comments section about which outfalls are representative_. Please distribute to all appropriate staff. We will begin forwarding all requests for ROS to the regions from now on. If anyone needs assistance from the Central Office on any of these requests, please let us know. Also, if you have any concerns or of 2 6/4/2008 9:14 AM kpproving Representative Outfall Status - Transition to Regions questions, please let me or Bradley know. Thanks so much, BG Bethany Georgoulias Environmental Engineer NC DENR Division of Water Quality Stormwater Permitting Unit tel. (919) 733-5083, ext. 529 fax (919) 733-9612 Content -Type: application/msword Representative Outfall Status Letter.doc — — — ! Content -Encoding: base64 I •I Content -Type: application/rnsword ! ''Rep Outfall Status —Guidance Memo.doc Content -Encoding: base64 l of 2 6/4/2008 9:14 AM wArF94 C 7 � r o �r June 4, 2008 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources To: Regional Office Staff From: The Stormwater Permitting Unit, Central Office Subject: Draft Guidance on Reviewing Requests for Representative Outfall Status Coleen H. Sullins, Director Division of Water Quality At the last East/West Consistency Meetings with the Regional Offices, regional staff indicated their willingness and preference to review and document approval of representative outfall status (ROS) requests from stormwater permittees. Before now, these requests were processed by the Central Office (CO). However, in'the past many requests were neglected or approvalldisapproval was left undocumented. Below is a draft checklist of review points and steps for approving and tracking representative outfall status in BIMS. We will go over this topic at either the next Consistency Meetings or other opportunity, but we wanted to provide guidance in the interim. If a request comes to the regional office in the meantime that you would prefer CO staff to handle, we will be glad to coordinate review with you until we can provide more training. 1. A word about a Representative Outfall Status request: a) Our permittees may be eligible for representative outfall status based on the physical facts at their site and on some other qualifying criteria. However, granting of ROS is at DWQ discretion. We owe the permittee an evaluation but not a specific outcome. The SPU has routinely denied ROS based on review of the submittal documents.or report from the regional office (RO). 2. Guidance on evaluating the initial request: a) Does the permittee's letter identify a physical basis for the request? (in other words, does it state that the character of the stormwater pollution, or the potential stormmater pollution or exposure is similar in the sub -drainage areas under consideration?) REQUIRED, unless b. applies. b) Or, if not very similar, has the permittee indicated that the representative outfall includes the sub -drainage area with the most stormwater pollution, or the potential for the most pollution or exposure (i.e., the "worst" sub -drainage area?) REQUIRED if a. does notapply. c) While the objective of ROS is to reduce the monitoring burden on the permittee, reducing the permittee's costs is absolutely conditional on establishing the representativeness of the outfall. We cannot grant ROS simply because we think the permittee deserves.a financial break. d) Has the permittee provided a site drawing to show which outfalls he/she is proposing to be considered representative of which other outfalls, and which ones will continue to be sampled as single outfalls? A'MCarolina Naturally North Carolina Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-5083 Customer Service Internet: www.ncwaterguality.org Location: 512 N. Salisbury St. Raleigh, NC 27604 Fax (919) 733-9612 1-877-623-6748 An Equal opportunrty/Affirmative Action Employer — 50% Recycledh 0% Post Consumer Paper Draft Guidance — Reviewing Requests for Representative Outfall Status June 4, 2008 e) Consider the type of industrial activity. For example, landfills (NCG12) and mines (NCG02) have changing footprints with perhaps higher potential for activities in a sub -drainage area to change, which might affect our discretion. Also, ready -mix concrete (NCG14) and mines may have wastewater discharges on site with the potential for the two waters to commingle, which might affect our discretion. f) If the request is for an individual permit, are the monitoring parameters the same across all the outfalls being considered as representative/represented? g) Vehicle Maintenance Activity (VMA) outfalls may not be represented by non-VMA outfalls, and vice -versa. 3. Review the file materials and BIMS: a) Receiving water classification? This may affect our discretion. For example, approving ROS for discharges to ORW/HQW receiving waters may not be appropriate. b) Receiving water special circumstances? Impaired? For what? Is there a TMDL? For what? Are there threatened or endangered species? All could affect our.discretion. c) Has the permittee paid up? Could withhold ROS until he/she has paid past -due amounts. d) Past compliance history should affect our discretion. Check file and/or BIMS for violations, enforcement, comments, history, etc. and consider how this should weigh into a ROS approval. e) Has past monitoring been complete? If the permittee has ignored past monitoring, may consider denying ROS approval until there is enough monitoring data to support the assertion of similar or less stormwater- pollution potential in the sub -drainage areas to be represented. How much is "enough"? Ideally a minimum of eight (8) to 10 samples, but may consider fewer if other evidence supports ROS request. 4. Visit the site: a) Do the physical facts verify the characterization that one outfall should be considered representative of another? b) Check out the Stormwater Pollution Prevention Plan (SPPP) — is it descriptive of site conditions? Is the permittee using the SPPP as a management tool and living record? Does it demonstrate that the permittee is actively aware of and managing stormwater discharges from the site? If you think it is warranted, consider requiring an updated/sufficient SPPP before continuing review of the ROS request. c) How is general housekeeping? if poor, consider whether the operator can confidently assert that one outfall is representative of others. d) Try to pre-empt any misunderstanding about ROS: it allows the analytical monitoring at one outfall to be considered as representative of other outfalls. ROS does not change the monitoring frequency required; nor does it change the required monitoring parameters; nor does it reduce the qualitative monitoring required at all outfalls. e) You may also need to explain that the final determination is based on the physical facts and DWQ's discretion. We are not obligated to approve a ROS request. _ f) Emphasize with the permittee that if the permit requires a tiered response to benchmark exceedences, then an exceedence at the representative outfall requires a response action in ALL of the sub -drainage areas represented by the one outfall. Draft Guidance — Reviewing Requests for Representative Outfall Status ,Jude 4, 2008 5. Procedure for tracking and documenting representative outfall status: a) Copy the ROS request letter (and site plan if submitted) to the Central Office/SPU. b) Update BIMS under the Events Tab with the date for 'Representative Outfall Status Requested." c) We are providing a template letter of ROS approval for your use (electronic file attached). Please feel free to modify it as necessary. d) If you deny the ROS request, list specifically the basis for denial. If the denial is temporary, note the conditions that need to be corrected before a re -visit and granting of ROS. e) Be sure to remind the permittee that qualitative monitoring (visual and odor characterization of the discharge) is still required at all outfalls. Also remind the permittee that a tiered response (if required by their permit) must be implemented in the other represented sub -drainage areas. f) Copy the final ROS approval or denial letter to (1) Central Office/SPU and (2) DWQ Central Files. g) Update BIMS under the Events Tab with date for "Representative Outfall Status Approved." Be sure to include information in the Comments section about which outfalls are representative. cc: Stormwater Permitting Guidance Materials File Non -point Source Compliance and Assistance Unit (NPSC&AU) DWQ Supervisor, Raleigh Regional Office DWQ Supervisor, Mooresville Regional Office DWQ Supervisor, Asheville Regional Office DWQ Supervisor, Winston-Salem Regional Office DWQ Supervisor, Wilmington Regional Office DWQ Supervisor, Washington Regional Office DWQ Supervisor, Fayetteville Regional Office City January 18, 2007 USF Holland Attn: Mr. Rich Hockett, Operations Supervisor 201 Stage Coach Trail Greensboro, N.C. 27409 SUBJECT: Industrial Compliance Inspection Inspection location: USF Holland 201 Stage Coach Trail SW Permit #: NCG 080653 Dear Mr. Hockett: )oro On January 11, 2007, the City of Greensboro Stormwater Management Division completed an industrial compliance inspection of the USF Holland terminal. Local regulations permit an inspection of industrial facilities under authority granted by City of Greensboro Code of Ordinance Chapter 27, Article 1, Section 27-9(e). This inspection consisted of two parts: a review of the facility files/records and an on -site facility inspection. The inspection was performed by Michael Borchers and the following deficiencies/observations were noted during the inspection. Site Plan and Stormwater Pollution Prevention Plan ♦ The facility does not have a Stormwater Pollution Prevention Plan as required by NCDENR DWQ General Permit No. NCG080000. ♦ The facility inspection program is inadequate. The last facility inspection was performed on January 3, 2005. The facility is required to inspect all Stormwater systems on at least a semi-annual schedule. Spill Prevention and Response Plan ♦ The facility does not have a Spill Prevention and Response Plan as required by NCDENR DWQ General Permit No. NCG080000. ♦ The facility does have some spill cleanup materials however the materials are inadequate for containment and not readily accessible. Preventative Maintenance and Good Housekeeping ♦ A program should be implemented to provide for routine trash pick up around the perimeter of the site. ♦ Numerous vehicle fluid leaks evident, particularly around the vehicle maintenance building. A good housekeeping program should be promptly implemented to contain vehicle fluid leaks/spills. Employee Training ♦ Since the permit was issued in September 2000, no employee training has occurred on spill response procedures or prohibited Stormwater / wastewater discharges. Non-Stormwater Discharge P.O. Box 3136 • Greensboro, NC 27402-3136 9 www.greensboro-nc.gov + (336) 373-2065 • TTY # 333-6930 ♦ No analytical monitoring had been conducted as required by the subject permit. ♦ Evidence of vehicle oil release /spill was observed in the area adjacent to the vehicle maintenance building. Based on the above deficiencies, the City of Greensboro will notify the North Carolina Department of Environment and Natural Resources (NCDENR). USF Holland may be notified by NCDENR in advance of this inspection so proper scheduling of personnel can take place. Furthermore, any penalties assessed against the City by the State as a result of this non-compliance may be assessed against USF Holland. If you have any questions concerning this letter or the enclosed inspection report, please contact me at 373-2494. Respectfully, Michael Borchers, P&E Supervisor City of Greensboro, Stormwater Management Division Enclosure: Industrial Inspection Report cc: Kenny McDowell, Manager of Stormwater Management Division David Phlegar, Water Quality Supervisor Corey Basinger, N.C. Dept. of Environment and Natural Resources Industrial Inspection File P.O. Box 3136 • Greensboro, NC 27402-3136 • vv",w.areensboro-nc.gov • (336) 373-2065 + TTY 4 333-6930 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCGO80000 CERTIFICATE OF COVERAGE No. NCG080653 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, USF HOLLAND INC is hereby authorized to discharge stormwater from a facility located at USF HOLLAND INC - GREENSBORO 201 STAGE COACH TRAIL GREENSBORO GUILFORD COUNTY to receiving waters designated as Horsepen Creek, a class WS-III NSW stream, in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, II, III, IV, V, and VI of General Permit No. NCGO80000 as attached. This certificate of coverage shall become effective September 1, 2001 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day August 23, 2002. 6 — for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality August 23, 2002 SUZ1E ANDREWS USF HOLLAND INC - GREENSBORO 201 STAGECOACH TRAIL GREENSBORO, NC 27409 Subject: NPDES Stormwater Permit Renewal USF Holland Inc - Greensboro COC Number NCGO80653 Guilford County Dear Permittee: Your facility was recently granted coverage under stormwater general permit NCG080000. This letter serves as your notification that the Division of Water Quality (DWQ) has reissued the general permit and that your facility's coverage will continue under the conditions of the reissued general permit. Please review the new permit to familiarize yourself with the changes in the reissued permit. The permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983. The following information is included with your permit package: * A new Certificate of Coverage * A copy of General Stormwater Permit NCGO80000 * A copy of the Analytical Monitoring Form (DMR) * A copy of a Technical Bulletin for the general permit Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact Bill Mills of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 548 Sincerely, t5 Bradley Bennett, Supervisor Stormwater and General Permits Unit cc: Central Files Stormwater & General Permits Unit Files Winston-Salem Regional Office 17 NCDENR N. C. Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 Custemer Service 1- 800-623-7748 FWArF O� RpG Michas! F. Easley Governor {! C� r William G. Ross Jr., Secretary 1 Department of Environment and Natural Resources Gregory J. Thorpe, Ph-D., Acting Director Division of Water Quality April 19, 2002 Mr. Stephan J. Wonch USF Holland Inc. 750 East 401h Street Holland, MI 42423 Subject: General Permit No. NCGO80000 USF Holland Inc. COC NCG080653 Guilford County Dear Mr. Wonch: In accordance with your application for discharge permit received on February 11, 2002, we are forwarding herewith the subject certificate of coverage to discharge under the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. If any parts, measurement frequencies of sampling requirements contained in this permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, this certificate of coverage shall be final and binding. Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Mack Wiggins at telephone number 919/733- 5083 ext. 542. cc: Winston-Salem Regional Office Central Files Stortnwater and General Permits Unit Files Sincerely, i[1f 1t3u1tYt �i• +�1,�ri •� Gregory J. Thorpe, Ph.D 9*A Z6MR Customer Service 1 800 623-7748 Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 1'.. STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG080000 CERTIFICATE OF COVERAGE No. NCG080653 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, USF Holland Inc. is hereby authorized to discharge stormwater from a facility located at USF Holland Inc. 201 Stage Coach Trail west of Guilford Guilford County to receiving waters designated as an unnamed tributary to Horsepen Creek in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I,1I, II1, IV, V, and VI of General Permit No. NCGO80000 as attached. This certificate of coverage shall become effective April 19, 2002 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day April 19, 2002 nn t ■��>�l�l� Cl�l1� for Gregory 1. Thorpe, Ph.D, Acting Director Division of Water Quality By Authority of the Environmental Management Commission 01 000 �� � `'l f�, /1 • �.^ e o e •ram .� t � — - I ` �- iNi fJ f� ' �� • iJ 1 EM �C%' C � r •!s vi l . • _ '� �i. �' sad � �. In �t o j BM f5 i �J u ! �. a n r �' •. gy � `� ', ` � •.dry �� so � � — ! �. f •�. - � .. _� lkf- �.:�. ;� t � �• p C,s�O`Iln • • � � �.Y. � �, i l / � l�. - R�: +°j�{� I , • r ! �• Pec`slmfav� • o , o* �. � +, !�• sGo � `! . � . Ch •r J�, ,=•' t • z. P f It c. Y - 11 ,L1 �-••, - 1 j tiF i J - �> � �' _ � .sC�� n • i '. t^ .! tZ- -� Hey ,�? � � � r ?�e � `"� °' ��i ` y, t � ,' � _.z"�° f t � yam,' • � � gip, �.-i.. �;�- � I. t.! _ \. � `� Copvri9ht (C) 1997, Maptech. Inc Markers Name: Discharge Site-NCG080653 Short Name: Dschrg Coordinates: 0360 04' 46.0" N, 0790 54' 50.5" W Comment: USF Holland inc.,Subbasin-030602, Cape Fear River Basin, Guilford County, Horsepen Creek, Class-WS III NSW, Quad C19SE