HomeMy WebLinkAboutNCG030685_COMPLETE FILE - HISTORICAL_20170901STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /V DOC TYPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ j b/ 7 C) 9 c YYYYMMDD e -_ Energy. Mineral & Land Resources ENVIRONMENTAL QUALITY September 1, 2017 Mr. Michael Meguiar Unison Engine Components 502 Sweeten Creek Industrial Park Road Asheville, NC 28803 ROY COOPER Governor MICHAEL S. REGAN Secrrrary TRACY DAVIS Director Subject: General Permit No. NCG030000 Unison Engine Components COC No. NCGO30685 Buncombe County Dear Mr. Meguiar: In accordance with your application for a discharge permit received on June 26, 2017, we are forwarding herewith the subject certificate of coverage (COC) to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). In conjunction with the issuance of this COC for an NPDES stormwater general permit, we are rescinding the No Exposure Certification No. NCGNE1040 that previously applied to this facility. Please take notice that this certificate of coverage is not transferable except upon approval of the Division of Energy, Mineral, and hand Resources. The Division of Energy, Mineral, and Land Resources may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Resources, the Coastal Area Management Act, or any ocher federal or local government permit that may be required. Nothing Compares_,.._. SState of North Carolina I Environmental Quality I Energy, Mineral and Land Resources 512 N. Salisbury Street 1 1612 Mail Service Center I Raleigh. North Carolina 27699-1612 919 707 9200 If you have any questions concerning this permit, please contact Bethany Georgoulias at telephone number (919) 807-6372 or by email bethany.georMulias(a),nederingov. Sincerely, Original sighed by B. Georgoidias for Tracy E. Davis, P.E., CPM, Director Division of Energy, Mineral, and Land Resources cc: Asheville Regional Office Michelle Hedrich (michelle-hedrich@jze.com Stormwater Program Files DWR Central Files Nothing Compares—, State of North Carolina I Environmental Quality I Energy, Mineral and Land Resources 512 N. Salisbury Street 11612 Mall Service Center I Raleigh. North Carolina 27699-1612 919 707 9200 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG030000 CERTIFICATE OF COVERAGE No. NCGO30685 STORMWATER DISCHARGES NATIONAL PO-LLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Unison Engine Components is hereby authorized to discharge stormwater from a facility located at Unison Engine Components 502 Sweeten Creek Industrial Park Road Asheville Buncombe County to receiving waters designated as Sweeten Creek, a class C water in the French Broad River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, 11, III, and IV of General Permit No. NCGOOOOOO as attached. 3 This certificate of coverage shall become effective September 1, 2017. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this 1st day of September 2017. Originol signed by B. Georgoulias for Tracy E. Davis, P.E., CPM Director, Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission LOCATION MAP: . 2 J'1 Ur i 11, e kk C—A Y Is ah... Unison Engine Components -, !.' I zz 'I I '.7 -6. Vj�A, --.—A C7, "K. lkll fft r, tE 4V it w p, r r V— =V= 6 NCG030685 wlsl E Map Scale 124, 000 Unison Engine Components Latitude, 350 32' S5" N Longitude., 820 30' 58" W County: Buncombe Receiving Stream: Sweeten Creek Stream (lass: C Index Number: 6-78-24 (French Broad River Basin) Facility Location Georgoulias, Bethany From: Georgoulias, Bethany Sent: Tuesday, September 05, 2017 9.45 AM To: 'Hedrich, Michelle (GE Aviation, US)' Subject: RE: Unison Engine Components - NOI for NCG03 Permit Coverage Attachments: NCG030685_COC.pdf, NCG030685_Cover Letter.pdf Good morning, Michelle, I wanted to send a copy of the final permit COC that we issued, and confirmation that we have rescinded NCGNE1040 for this site. Please see attached and let me know if you have any questions. The package will out to Mr. Meguiar this week. Best regards, Bethany Georgoullas Environmental Engineer Stormwater Program, Division of Energy, Mincral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethany.georgoulias@ncdenr.gov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: htt :llde .nc. ov/about/divisions/ener -mineral-land-resources/storniwater Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Hedrich, Michelle (GE Aviation, US) [mailto:Michelle.Hedrich@ge.com] Sent: Monday, August 28, 2017 11:30 AM To: Georgoulias, Bethany<bethany.georgoulias@ncdenr.gov> Subject: RE: Unison Engine Components - N01 for NCG03 Permit Coverage Bethany, There is only one discharge point. Thankyou! Michelle From: Georgoulias, Bethany [mailto:bethan eor oulias ncdenr. ov] Sent: Monday, August 28, 2017 10:27 AM To: Hedrich, Michelle (GE Aviation, US) <Michelle.Hedrichgge.com> Subject: EXT: Unison Engine Components - NOI for NCG03 Permit Coverage Michelle, I was out of the office for a few weeks, and I'm catching upon permits. I'm working on the COC for Unison Engine Components in Asheville now (which will be issued in conjunction with a rescission of the current NCGNE1040 No Exposure Certification). I need to enter outfall points into our database, but the question on the NOI about how many stormwater outfalls there are at this facility is blank. How many discharge points do they have? I see one obvious one on the attached site plan map, but the sheet is very small, and I can't clearly see others. Thank you, Bethany Bethany Georgoulias Environmental Engineer Stonriwater Program, Division of Energy, Mineral, and Land Resources N.C. Department of Environmental Quality 919 807 6372 office bethany.geor oulias a,ncdenr.gov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: htt :/n /deg.nc.gov/about/divisions/energy-mineral-land-resources/stormwater Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Central Files: APS _ SWP 9/5/2017 Permit Number NCG030685 Permit Tracking Slip Program Category Status Project Type NPDES SW Active New Project Permit Type Version Permit Classification Metal Fabrication Stormwater Discharge COC 1.00 COC Primary Reviewer Permit Contact Affiliation Bethany. Geo rgoulias Coastal SWRule Permitted Flow Facility Facility Name MajorlMinor Region Unison Engine Components Minor Asheville Location Address County 502 Sweeten Creek Industrial Park Rd Buncombe Facility Contact Affiliation Asheville NC 28803 Michelle Hedrich 502 Sweeten Creek Industrial Park Rd Owner Asheville NC 28803 Owner Name Owner Type Unison Engine Components Nan -Government Owner Affiliation Michelle Hedrich 502 Sweeten Creek Industrial Park Rd Dates/Events Asheville NC 28803 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 9/1/2017 6/26/2017 9/1/2017 9/1/2017 10/31/2017 Regulated Activities Requested /Received Events Metal products manufacture RO staff report received 7131/17 RO staff report requested 7124/17 O utfa l l 001 Waterbody Name Streamindex Number Current Class Subbasin Sweeten Creek (Busbee Reservoir) 6-78-24 C 04-03-02 db — I h. Georgoulias, Bethany From: Kucken, Darlene Sent: Monday, July 31, 2017 118 PM To: Georgoulias, Bethany Subject: RE: NO[ from Unison Engine Components for NCG03 I have no concerns at this time. I will see that our files reflect this new permit. Darlene Kucken - Darlene. Kucken@ncdenr.gov North Carolina Dept. of Environmental Quality Asheville Regional office Division of Energy, Mineral, and Land Resources 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. `Aj Go Green! Print this email only when necessary. Thank you for helping NCDENR be environmentally responsible. From: Aiken, Stan E Sent: Monday, July 24, 2017 2:50 PM To: Kucken, Darlene <darlene.kucken@ncdenr.gov> Subject: FW: N01 from Unison Engine Components for NCG03 FYI From: Georgoulias, Bethany Sent: Monday, July 24, 2017 11:06 AM To: Aiken, Stan E <stan.aiken@ncdenr.gov> Subject: NOI from Unison Engine Components for NCG03 Good morning, Stan, We received an NOI from Unison Engine Components in Asheville for coverage under NCG03. They have been under a No Exposure exclusion (NCGNE1040) and have determined the need for an NPDES stormwater permit now. We will rescind the NCGNE upon issuance. Here is a link to the NOI: http://edocs.deg.nc.pov/Stormwater/0/doc/552316/Pagel.aspx Does ARO have any concerns with issuing a COC to this site? Thanks, Bethany Bethany Georgoulias E-nvironntental Engineer 4k Stormwater Program, Division of Isnergy,. Mineral, and Land Resources N.C. Department of Environmcntal Quality 919 807 6372 office bethan eor oulias ncdenr. ov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: http://deq.nc.gov/about/divisions/energy-inineral-land-resources/stonnwater Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Ai Georgoulias, Bethany From: Kucken, Darlene Sent: Monday, July 31, 2017 1:55 PM To: Georgoulias, Bethany' Subject: RE: NOI from Unison Engine Components for NCG03 �2L, �tJ s Sze Bethany,IV In further review, I want to be sure that you are aware that Laura granted regulatory relief from tiered sampling in 2014 for this facility under permit NCG030543. It appears that NCG030000 is at the same address. Bottom line, it's likely a good thing they are getting the entire address under a SW permit and I'm not sure why they would even have a NE at a permitted facility (?) Let me know if you need anything else. Darlene Kucken - Darlene.Kucken@ncdenr.gov North Carolina Dept. of Environmental Quality Asheville Regional Office Division of Energy, Mineral, and Land Resources 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. `Aj Go Green! Print this email only when necessary. Thank you for helping NCDENR be environmentally responsible. From: Kucken, Darlene Sent: Monday, July 31, 2017 1:18 PM To: Bethany Georgoulias(bethany.georgoulias@ncdenr.gov) <bethany.georgoulias@ncdenr.gov> Subject: RE: N01 from Unison Engine Components for NCG03 I have no concerns at this time. I will see that our files reflect this new permit. Darlene Kucken - Darlene. Kucken@ncdenr.gov North Carolina Dept. of Environmental Quality Asheville Regional Office Division of Energy, Mineral, and Land Resources 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. V,A Go Green! Print this email only when necessary. Thank you for helping NCDENR be environmentally responsible. From: Aiken, Stan E Sent: Monday, July 24, 2017 2:50 PM To: Kucken, Darlene <darlene.kucken@ncdenr.gov> Subject: FW: NOI from Unison Engine Components for NCG03 FYI From: Georgoulias, Bethany Sent: Monday, July 24, 2017 11:06 AM To: Aiken, Stan E <stan.aiken@ncdenr.gov> Subject: NOI from Unison Engine Components for NCG03 Good morning, Stan, We received an NOI from Unison Engine Components in Asheville for coverage under NCG03. They have been under a No Exposure exclusion (NCGNE1040) and have determined the need for an NPDES stormwater permit now. We will rescind the NCGNE upon issuance. Here is a link to the NOI: http://edocs.deg.nc.gov/Stormwater/0/doc/552316/Pagel.aspx Does ARO have any concerns with issuing a COC to this site? Thanks, Bethany 13ethany Georgoulias Environmental 1?ngineer Stormwater Program, Division of Energy, Mineral, and [.and Resources N.C. Department of Environmental Quality 919 807 6372 office bet hany. iasPncdenr.gov 1612 Mail Service Center, Raleigh, NC 27699-1612 (mailing) 512 N. Salisbury Street, Raleigh, NC 27604 (location) Website: http://deq.nc.gov/about/divisions/energy-mineral-land-resources/stormwater Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Compliance Inspection Report Permit: NCG0306a5 Effective: 11/16/17 Expiration: 10/31118 Owner: Unison Engine Components SOC: Effective: Expiration: Facility: Unison Engine Components County: Buncombe 502 Sweeten Creek Industrial Park Rd Region: Asheville Asheville NC 28803 Contact Person: Michelle Hedrich Title: Phone: 829.232-8455 Directions to Facility: from 140 take 25 Alt south for 112 mile to Sweeten Creek Industrial Park Road, 502 is at the end of Sweeten Creek Industrial Park Road. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Rep rosenlative(s): Related Permits: Inspection Date: 08/08/2018 Entry Time: 01:OOPM Exit Time: 02:15PM Primary Inspector. Isaiah L Reed Phone: 828-296-4614 Secondary Inspector(s): Reason For Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Metal Fabrication Stormwater Discharge COC Facility Status: ® Compliant ❑ Not Compliant Question Areas: 0 Storm water (See attachment summary) Page: 1 Permit: NCG030885 Owner - Facility: Unison Engine Components Inspection Date: 0810812018 Inspection Type : COrMPIOMO Evaluatior) Reason for Visit: Routine Inspection Summary: On August 8, 2018 this facility was inspected for compliance. I met with Michelle Hendrich on site. No issues were observed during the inspection. If you have any questions, please call 828-296-4614. Page; 2 permit: NCG030685 Owner - Facility: Unison Engine Components Inspection Dale: 08/08/2018 Inspection Type : Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ■ ❑ ❑ Q # Does the Plan include a "Narrative Description of Practices"? E ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? E ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? 0 ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? E ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ® ❑ ❑ ❑ # Does the Plan include a BMP summary? N ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ ❑ ❑ # Does the facility provide and document Employee Training? ! ❑ ❑ ❑ # Does the Plan include a list of Responsible Pany(s)? ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? E ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑ ❑ ❑ Comment: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ® ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ■ ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? N ❑ ❑ ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all oulfalls observed during the inspection? ❑ ❑ ❑ # If the facility has representative outfall status, is it property documented by the Division? ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? N ❑ ❑ ❑ Comment: Page: 3 �z Facility Name: \ PermitM "u, Time in/otit- �c. 4 (�.�i 5VII Date: V�•"LJ�M „"' Stormwater Pollution Prevention Plan °Does the site have a SWPPP? Does the Plan include a General Location (USGS) map? Does the Plan include a "Narrative Description of Practices"? Does the Plan include a detailed site map including outfall locations and drainage areas? Does the Plan include a list of significant spills occurring during the past 3 years? Has the facility evaluated feasible alternatives to current practices? (Does the facility provide all necessary secondary containment? Does the Plan include a BMP summary? (Does the Plan include a Spill Prevention and Response Plan (SPRP)? Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ;Does the facility provide and document Employee Training? ~ Does the Plan include a list of Responsible Party(s)? ils the Plan reviewed and updated annually? Does the Plan include a Stormwater Facility Inspection Program? ,Has the Stormwater Pollution Prevention Plan been implemented? Energy Mineral and t.crnd2esouree.v eIIIRDNMENT/ ( WALITT von nin rae NE 4ualitatiyeMonitoring Yes Na NA NE ;Has the facility condusted its Qualitative monitoring semi-annually? ❑. ❑ ❑ . _❑ Analytical -Monitoring I Yes No NA NE ;Has the facility conducted its Analytical monitoring? - - .❑ _❑ ❑ ❑ Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas?T Yes No NA NE ;Is a copy of the Permit and the Certificate of Coverage available at this site? Were all outfalls observed during the inspection? elf the i an 1-1 ty has representative outfall status, 1s it properly documented by the Division? Has the facility evaluated all illicit (non stormwater) discharges? -omments and Others Present; � 6n C� 1 r, na U'aF 1 " I /i Ap Energy, Mineral and Land Resources ENVIRONMENTAL QUALITY Unison Engine Components — GE Aviation Attn: Michael Meguiar 502 Sweeten Creek Industrial Park Road Asheville, NC 28803 May 4, 2018 Subject: NPDES Stormwater Permit Permit No. NC6030685 Representative Outfall Status Request Unison Engine Components - GE Aviation Buncombe County Dear Mr. Meguiar: ROY COOPER Governor MICHAEL S. REGAN Secretary WILLIAM E. VINSON, JR. Interim Director The Asheville Regional Office staff have reviewed your request dated March 16, 2018, for a determination that stormwater discharge outfall (SDO) OS5 be granted representative outfall status for stormwater outfalls OSI, OS2, OS3, OS4. Based on the information and maps provided and a site inspection on February 20, 2018, we are approving this request. In accordance with 40 CFR §122.21(g)(7), you are authorized to sample outfall number OS5 as a representative outfall. This approval is effective with the next sampling event. We also want to remind you that the permit still requires Qualitative Monitoring be performed at all _SDOs, regardless of representative status. Please remember that any actions you initiate in response to benchmark exceedances as directed in the tiered response provisions of your permit must address all drainage areas represented by OS5, where appropriate. Please append this letter to your Stormwater Pollution Prevention Plan (SPPP) or permit to document that representative outfall status has been approved. If changes in drainage areas, structures, processes, storage practices, or other activities occur that significantly alter the basis of this approval, representative outfall status may no longer be valid. You should either resume sampling at all SDOs, or reapply to this office for representative outfall status based on updated information. If you have any questions or comments concerning this letter, please contact Shawna Riddle or me at 828-296-4500. Sincerely, r tanley E. Aiken GA Regional Engineer Land Quality Section Enclosure: Inspection Report cc: Bethany Geor otllias a,ncdenr. og_y, Environmental Engineer Lucy.Crockern,_ eg co,m, Lead EHS Specialist, GE Aviation State of North Carolina I Environmental Quality I Energy, Mineral and Land Resources 2090 US 70 highway I Swannanoa, NC 28778-8211 828 296 4500 T Compliance Inspection Report Permit: NCG030685 Effective: 11/16l17 Expiration: 10/31/16 Owner: Unison Engine Components SOC: Effective: Expiration: Facility: Unison Engine Components County: Buncombe 502 Sweeten Creek Industrial Park Rd Region: Asheville Asheville NC 26803 Contact Person: Mk*e4e--Hedith Title: Phone: 829-23 Directions to Facility: from 1-40 take 25 Aft south for 1/2 mile to Sweeten Creek Industrial Park Road, 502 is at the end of Sweeten Creek Industrial Park Road. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): On -site representative Lucy Crocker Related Permits: Inspection Date: 02/20/2018 Entry Time: 11:OOAM Exit Time: 12:45PM Primary Inspector: Shawna Riddle e av� Phone: Secondary In5pector(s): �V� Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Metal Fabrication Stormwater Discharge COC Facility Status: Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Page: i Permit: NCG030685 Owner- Facility. Unison Engine Components Inspection Date: 02120/2018 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: Met with Lucy Crocker for the inspection. Inspection was to determine representative outfall status for the Building 502 NCGO30685 permit. The SPPP is current and monitoring is being conducted as required. Representative outfall status will be approved for this site. You are authorized to sample Outfall OS5 as a representative outfall for outfalls OS1, OS2, OS3, and OS4. This approval is effective with the next sampling event. Page: 2 permit: NCG030685 Owner - Facility: Unison Engine Components Inspection Date: 02/2012018 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yea Na NA NE Does the site have a Stormwater Pollution Prevention Plan? ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ❑ ❑ ❑ # Does the Plan include a `Narrative Description of Practices'? ® ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ® ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? E ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? 0 ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? 0 ❑ ❑ ❑ # Does the Plan include a BMP summary? 0 El ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? 0 ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ ❑ ❑ ❑ # Does the facility provide and document Employee Training? 0 ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ■ ❑ ❑ ❑ # Is the Plan reviewed and updated annually? 0 ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? 0 ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ® ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? 0 ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? E ❑ ❑ E] Comment. - Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? N ❑ ❑ ❑ # Were all outfalis observed during the inspection? N ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ 1:10 ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ 0 ❑ Comment: Page: 3 NCDENR k�:r♦pwi.1EM� aM� 4.fi,.'k FRaa.F�^17 Division of Water Quality / Surface Water Protection FO ' �NCY" US[; ONLY Dal "1VL'd Yea orslp"3 ay National Pollutant Discharge Elimination System _"�RPs REPRESENTATIVE OUTFALL STATUS (ROS Aq J ,2O REQUEST FORM a �% F If a facility is required to sample multiple discharge locations with very similar stormw-bW the permittee may petition the Director for Representative Outfall Status (ROS). DWQ may grant �e Outfall Status if stormwoter discharges from a single outfall are representative of discharges from le outfalls. Approved ROS will reduce the number of outfalls where analytical sampling requirements apply. if Representative Outfall Status is granted, ALl outfalls are still subject to the qualitative monitoring requirements of the facility's permit --unless otherwise allowed by the permit (such as NCG020000) and DWQ approval. The approval letterfrom DWQ must be kept on site with the facility's Storm water Pollution Prevention Plan. The facility must notify DWQ in writing if any changes affect representative status. R{�„ For questions, please contact the DWQ Regional Office for your area (seepage 3). "' W ., (Please print or type) I 1) Enter the permit number to which this ROS request applies: Qit Individual Permit (or) Certificate of Coverage sh0[,iz ect, Qh 2) Facility Information: Yl r So �CiY� _ l n &V Owner/Facility Name � } Facility Contact mi Ghd d e"q 14 (A V- Street Address City County Telephone No. U L S 1A lejffn LV ill N sto 4y Verr state NL ZIP Code 20503_ 66 h ( 669 be, _ E-mail Address b2i(P719& mP4uTarr" Fax: Ili 3) List the representative outfalls) information (attach additional sheets if necessary): f -# Outfall(s)� is representative of Outfaii(s) # ` Outfalls` drainage areas have the same or similar activities? iyes ❑ No Outfalls' drainage areas contain the same or similar materials? KYes ❑ No Outfalls have similar monitoring results? y1Yes ❑ No ❑ No data* Outfall(s) is representative of Outfall(s) Outfalls' drainage areas have the same or similar activities? ❑ Yes ❑ No Outfalls' drainage areas contain the same or similar materials? ❑ Yes ❑ No Outfalls have similar monitoring results? ❑ Yes ❑ No ❑ No data* Outfall(s) is representative of Outfall(s) Outfalls' drainage areas have the same or similar activities? ❑ Yes ❑ No Outfalls' drainage areas contain the same or similar materials? ❑ Yes ❑ No Outfalls have similar monitoring results? 0 Yes ❑ No ❑ No data* *Non-compliance with analytical monitoring prior to this request may prevent ROS approval. Specific circumstances will be considered by the Regional Office responsible for review. Page 1 of 3 SWU-ROS-2009 Last revised 12/30/2009 (093 Representative Outfall Status Request 4) Detailed explanation about why the outfalls above should be granted Representative Status: (Or, attach a letter or narrative to discuss this information.) For example, describe how activities and/or materials are similar. S(lf �, +tni . f_ _d 5) Certification: North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Managementl Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). I hereby request Representative Outfall Status for my NPbES Permit. I understand that ALL outfalls are still subject to the qualitative monitoring requirements of the permit, unless otherwise allowed by the permit and regional office approval. I must notify DWQ in writing if any changes to the facility or its operations take place after ROS is granted that may affect this status. If ROS no longer applies, I understand I must resume monitoring of all outfalls as specified in my NPDES permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Xt/ thaw( NeoRstrs r _ Title: e0" (Signature of Applican T (Date Signed) Please note: This application for Representative Outfall Status is subject to approval by the NCPENR Regional Office. The Regional Office may inspect your facility for compliance with the conditions of the permit prior to that approval. Final Checklist for ROS Request This application should include the following items: ' This completed form. la/ Letter or narrative elaborating on the reasons why specified outfalls should be granted representative status, unless all information can be included in Question 4. Two (2) copies of a site map of the facility with the location of all outfalls clearly marked, including the / drainage areas, industrial activities, and raw materials/finished products within each drainage area. IV Summary of results from monitoring conducted at the outfalls listed in Question 3. ❑ Any other supporting documentation. Page 2 of 3 SWU-ROS-2009 Last revised 12/3012009 i Shawna Riddle from local Asheville NCDEQ office was onsite February 20, 2018 for storm water inspection for both buildings (401 and 502). Buildine 401 i401 Sweeten Creek Industrial Parki: The property is bordered on the north by a tributary to Sweeten Creek and on all other downgradient side by industrial properties. The manufacturing operations are enclosed in buildings covered by a roof and the surrounding vehicle operation areas are paved with asphalt and gravel. Trialers are parked in the southern portion of the property (lot leased to UPS). Shipping and receiving areas are located on the south and southwest corner of building 401. Employee parking is the west of building 401. Employee and visitor parking are also present in an asphalt paved, unfenced lot to the north of building 401. The remainder of the property consists of landscaped property (grassed yard) north of building 401. Rain water falling on the property is primarily collected in the catch basins or drainage ditches and is discharged offsite to roadside ditches north and northeast of the plants which subsequently discharge to the Sweeten Creek tributary. Building 401 site is approximately 8.6 acres in area and is currently occupied by a one-story facility with about 102, 051 square feet of office, manufacturing and warehouse space. A one-story chemical building (2,170 sq, ft.) is present south of building 401. The plant is bordered to the south, west and north by pavement, consisting of parking lots, loading docks, or driveways. The basic layout of the plant is such that the truck loading and unloading docks are out the south and southwest sides of the building and the administrative offices are on the north side of the building. Most of the plant space is devoted to manufacturing activities and product storage. Thestormwater runoff from roof drains, the above ground storage tank area, loading docks, material storage areas and surrounding driveways or parking lots is generally collected by catch basins located on the around the perimeter of the plant. The catch basins on the south, east and north side of the plant discharge to Outfall 001. The catch basins on the east and northeast side of the plant discharge to Outfall 002. One catch basin on the south side of the plant is routed to the adjoining UPS property (shared outfall) and discharges to Outfall 005. Please note that Outfall 003, 004 and 006 drain other portions of sweeten creek industrial park not occupied by GE Aviation. We are wanting to move to ONLY sample from outfall q1. Outfall #2 borders with another facility and only grass and parking lot. Outfall #5 is a shared outfall with UPS next door due to storm drain leading into their storm drain. The tank located near the storm drain has adequate secondary containment and truck operators have been instructed to use a drain cover during water removal from tank. Shawna Riddle from Asheville Local NCDEQ office has advised from her site visit that Outfall #1 would be a representative outfall for both. Building 502 J502 Sweeten Creek Industrial Park): Very little exists at this location would cause a concern related to stormwater runoff. However, this 120,000 SF building does have loading and unloading operations and parking on the southern and eastern sides. Therefore, in an abundance of caution, this site decided to permit building 502 rather than maintain exemption. The exposed pollutants would be limited to vehicle traffic and unloading/loading operations. Building 502 should be and would qualify for a no exposure certification. Our parent company of GE likes to air on the side of caution and has advised us to stay permitted under the General Storm water Permit. Outfall #5 is the only outfall that would see any action due to the covered areas for trash, recycling and waste. Also, due to the amount of new machines we are installing, occasionally there might be packing material staged outside for removal. Shawna Riddle from Asheville Local NCPEQ office has advised from her site visit that Outfat! ##.5 would be a representative outfall for all others due to no activity outside. 1 a Ss. 5.- trw LIM. - Ot 91. • SlArn- p . .11 w - f -- RR ;•� r;� S�S7 f I f :;l•. ;r.:.:+,'1- �.�-.-_-� _ ���. _ `v.n'*"y 'S'Y '�--'i--tea- ..�.`• :`♦ f J�7. /3' / J ov N: •Sncl.ua^�" 'I [ y r;�14 I 1 - i '� -- � --�.��' �;. iy; �`` K a9 poll \ t r I''�.,, 1 � y�•f."'1 Y' .5i // � ` R �F � '.?�$. ..'tee ..:.•. `:: 7 gacSs / Y b� I 'lilt IiiA� f� If �� r � g I s'' •� �r I J 8� � �■� !gilt rl� ���^ � ,,:'� '" >i4 �' �_ .•.�80�. - 1 , - I[ � " I : i �• t i 8 yaa ;. I 7tt =^IZU di A. �' a �m ME MEs ( 4/rib tiN ' 11 j 19- �� � � �� 4 tY; gx- I� '� i�;��'•''i:i�''1:1 lW'�: — -- •.9- ',", ' j�i' �' ��. 9 yippyyy _ F I$ kY� II <� !rF { d'�� �� 1ri `�, � s �+•�a:i .-y r c�'' �%y - � � :y W 5: .r*1�.y ' �. Is I Jill = ,� �•?'• flip;.; %1 j`••,: „'.T�.''Ls_.`:' - : /�_'`, t'; js+ .".r'•.. �4d g�G �ti I r /"l 4f! ':� lti - i/��N�� • i� .w •�"�• �� t S� �� ��� �"� 9 � ' i �1 �1�" '�', '�r1,4' J [ /�', ••■Y• � 1 `� ' i `ter � ��!'i • I' ��■a In , 1 li',Y.:' �. y _ 17 =D f `F{'a;,, • ';t�-`a• i:� off" Q �— ' 41, �ln z j' �.�-•'sl.,. r''�:%,-" s� -tip � � a' L -w^'•' ex STORMWATER Caunu Norm GE GE ISSUE ob1[ PLAN Farina Arialian Manufacturing Facility A5t-E1^LLL. NORTH CAROUNA _ wn. l P• m GOODWYNIMILLS I CAWOOD GMC#ANIGM73M39C-103 zt-L- y'. cilfr ISSUE FOR CONSTRUCTION • OP-1 cnec�ra c. 2701 1st A.anu• Swth, Suit. 100 1 94mingnam• AL 35233 Tel 20S.579.4462 j G1.ILNE T7ARK.COu r GOO / 'SQlcrth magery Date:_ t0i 18/2015 [at 35,5500411 Ion-82.521258' eiev 2160 h f SHEALY ENVIRONMENTAL SERVICES, INC. Detection Summary Bunnell-Lammons Engineering, Inc. Lot Number: SJ25055 Sample Sample ID Matrix Parameter Method Result Q Units Page 001 OUTFALL OS1 Aqueous TSS SM 25401)- 3.3 mg/L 5 001 OUTFALL OS1 Aqueous HEM (oil and grease) 1664E 1.8 J mg/L 5 001 OUTFALL 031 Aqueous Copper 200.8 1.0 J ug/L 5 001 OUTFALL OS1 Aqueous Zinc 200.8 79 ug/L 5 002 OUTFALL OS2 Aqueous TSS SM 254OD- 9.2 mg/L 6 002 OUTFALL OS2 Aqueous HEM (oil and grease) 1664E 2.0 J mg/L 6 002 OUTFALL OS2 Aqueous Copper 200.8 4.2 J ug/L 6 002 OUTFALL OS2 Aqueous Lead 200.8 0.38 J ug/L 6 002 OUTFALL OS2 Aqueous Zinc 200.8 150 ug/L 6 003 OUTFALL OS3 Aqueous TSS SM 254OD- 2.1 mg/L 7 003 OUTFALL OS3 Aqueous Copper 200.8 9.6 ug/L 7 003 OUTFALL 033 Aqueous Zinc 200.8 32 ug/L 7 004 OUTFALL OS4 Aqueous TSS SM 254OD- 7.2 mg/L 8 004 OUTFALL OS4 Aqueous Copper 200.8 1.4 J ug/L 8 004 OUTFALL OS4 Aqueous Zinc 200.8 20 ug/L 8 005 OUTFALL OS5 Aqueous TSS SM 254OD- 6.3 mg/L 9 005 OUTFALL OS5 Aqueous Copper 200.8 1.2 J ug/L 9 005 OUTFALL OS5 Aqueous Lead 200.8 0.27 J ug1L 9 005 OUTFALL 035 Aqueous Zinc 200.8 79 ug/L 9 (19 detections) Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.shealylab.com Page 4 of21 Client: Bunnell-Lammons Engine,' Inc. - Laboratory ID:SJ25055-001 - Description: OUTFALL OS1 Matrix: Aqueous Date Sampled:10/2312017 0945 Date Received:1012512017 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (TSS) SM 2540D-2011 1 10/26/2017 1529 KNF 55311 1 (BEAR (oil and) 16648 1 10/27/2017 0930 ARP 55408 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run TSS SM 254OD-20 3.3 1.0 0.50 mg/L 1 HEM (oil and grease) 1664B 1.8 J 5.0 1.8 m91L 1 ICP-MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 200.2 200.8 1 10/27/2017 2109 BNW 10/26/2017 0839 55257 CAS Analytical Parameter - Number - Method Result Q LOQ_ DL Units Run Copper 7440-50-8 200.8 1.0 J 5.0 0,63 ug1L 1 Lead 7439-92-1 200.8 ND 1.0 0.25 ug/L 1 Zinc 7440-66-6 200.8 79 10 2.5 ug1L 1 LQQ = Limit of Quantitation B = Detected in the method blank E • Quantitation of compound exceeded the calibraton range DL = DeteCtion Llmd NO = Not detected at or above the OL N = Recovery is out of criteria P - The RPO between two GC columns axceeds 40% 3 = Estimated result c LOQ and - DL }i = Out of holding time W = Reported on wet weight basis Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.shealyiab.com Page 5 of 21 a ,n r ClienLBunnell-Lammons Engineering, i oratory ID:SJ25055-002 Description: OUTFALL OS2 Matrix: Aqueous Date Sampled:10123/2017 0940 Date Received:10125/2017 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (TSS) SM 254OD-2011 1 10/26/2017 1529 KNF 55311 1 (HEM (oil and) 1664B 1 10/27/2017 0930 ARP 55408 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run TSS SM 254OD-20 9.2 1.7 0.50 mglL 1 HEM (oil and grease) 1664B 2.0 J 4.7 1.6 mglL 1 ICP-MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 200.2 200.8 1 10/27/2017 2115 BNW 10/26/2017 0839 55257 CAS Analytical Parameter _- Number - Method Result Q LOQ DL Units Run Copper 7440-50-8 200.8 4.2 J 5.0 0.63 ug1L 1 Lead 7439-92-1 200.8 0.38 J 1.0 0.25 ug1L 1 Zinc 7440-66-6 200.8 150 10 2.5 ug1L 1 LOG = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range DL = DeteCliDn Limit ND - Not detected at or above the DL N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40% J = Estimated result < LOG and - DL H = Out of holding time W = Reported on wet weight basis Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.shealylab.com Page 6 of 21 Client: Bunnell-Lammons Engineer Inc. _ - Laboratory ID: SJ25055-003 Description: OUTFALL OS3 Matrix: Aqueous Date Sampled:1012312D17 0935 Date Received:10125/2017 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (TSS) SM 254OD-2011 1 10/26/2017 1529 KNF 55311 1 (HEM (oil and) 1664B 1 10127/2017 0930 ARP 55408 CAS Analytical Parameter Number Method Result Q R LOG DL Units Run TSS SM 254OD-20 2.1 1.0 0.50 mg/L 1 HEM (Gil and grease) 1664E ND 4.7 1.6 mglL 1 ICP-MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 200.2 200.8 1 10/27/2017 2121 BNW 10/26/2017 0839 55257 CAS ,Analytical Parameter Number Method Result Q LOG DL Units Run Copper 7440-50-8 200.8 9.6 510 0.63 u91L 1 Lead 7439-92-1 200.8 ND 1,0 0.25 ug/L 1 Zinc 7440-66-6 200.8 32 10 2.5 ug)L 1 LOCI = Limit of Ouantitation B = Detected in the method blank E s ousntitabon of compound exceeded the calibration range DL = Detection Limit ND - Not detected at or above the DL N = Recovery is out of cnteda P - The RPD between Wo GC columns exceeds 405E J = Estimaled rasutl c LOO and � DL H = Out of holding time W = Reported on wel weight basis Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791.9111 www.Shealylab.com Page 7 of 21 • Client; Bunnell-Lammons Engineering, boratory I0:SJ25055-004 description: OUTFALL OS4 Matrix: Aqueous Date Sampled:1012312017 0930 Date Received:10/2512017 Inorganic non-metals _ Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (TSS) SM 25400-2011 1 10/26/2017 1529 KNF 55311 1 (HEM (oil and) 1664B 1 1D127/20170930 ARP 55408 CAS Analytical Parameter _ _ _ Number Method Result Q LOQ DL Units Run TSS SM 254OD-20 7.2 1,0 D.50 mg/L 1 HEM (oil and grease) 1664B ND 4.8 1.7 mglL 1 ICP-MS Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 200.2 200.8 1 10127/2017 2126 BNW 10/26/2017 0839 55257 CAS Analytical Parameter Number Method Result Q - --1.4 LOQ DL Units Run Copper 7440-50-8 200.8 J 5.0 0.63 ugfL 1 Lead 7439-92-1 200.8 ND 1.0 0.25 ug/L 1 Zinc 744046-6 200.8 20 10 2.5 uglL 1 LOQ = Limit o1 Quantitelion B = Detected in the method blank E = Quantitation o1 compound amaeded the calibration range DL - Detection Limit NO = Not detected at or above the DL N = Recovery is out or criteria P = The RPD batween two GC columns exceeds 40% J = Estimated result � 1-00 and � OL H = Out or holding time W = Reported on wet weight basis Sheaty Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791.9111 www.shealylab.com Page 8 of 21 Client-Bunnell-Lammons Engineer Inc. Laboratory ID: SJ25OSS-005 Description: OUTFALL OS5 Matrix: Aqueous Date Sam pled:1012312017 0925 late Received: 10125/2017 Inorganic non-metals Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (TSS) SM 25400-2011 1 10/26/2017 1529 KNF 55311 1 (HEM (oil and) 16648 1 10131/2017 0933 ARP 55708 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run TSS SM 254OD-20 6.3 1.1 0.50 mglL 1 HEM (oil and grease) 16648 ND 4.7 1.6 mglL 1 ICP-MS Run Prep Method 1 200.2 Analytical Method Dilution Analysis Date Analyst 200.8 1 10/27/2017 2132 BNW Prep Date Batch 10/26/2017 0839 55257 CAS Analytical Parameter _ _ Number Method Result Q LOQ OL Units Run Copper 7440-50-8 200.8 1.2 J 5.0 _ 0.63 ug/L 1 Lead 7439-92-1 200.8 0.27 J 1.D 0.25 ug/L 1 Zinc 7440-66-6 200.8 79 10 2.5 ug1L 1 LOO = Limit of Ovantilalion H = t]eleCted in the method blank E = OuanhWhon of compound exceeded the calibration range DL = DetaCtion Limit ND = Not detected at or above the OL N = Recovery is out o1 criteria P = The RPD between two GC columns exceeds 40% J = Estimated result - LOO and ? OL H = Out of holding time W = Reported on wet weight basis Shealy Environmental Services. Inc. 106 Vantage Point Drive West Columbia. Sr— 29172 (803) 791-9700 Fax (803) 791.9111 www.shealylab.com Page 9 of 21 Energy, Mineral & L and Resources ENVIRONMENTAL QUALITY September 1, 2017 Mr. Michael Meguiar Unison Engine Components 502 Sweeten Creek Industrial Park Road Asheville, NC 28803 ROY COOPER Governor MICHAEL S. REGAN secretary TRACY DAVIS Director Received SFP 8 2017 Laird Quality Section Asheville Subject: General Permit No. NCG030000 Unison Engine Components COC No. NCG030685 Buncombe County Dear Mr. Meguiar: In accordance with your application for a discharge permit received on June 26, 2017, we are forwarding herewith the subject certificate of coverage (COC) to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). In conjunction with the issuance of this COC for an NPDES stormwater general permit, we are rescinding the No Exposure Certification No. NCGNE1040 that previously applied to this facility. Please take notice that this certificate of coverage is not transferable except upon approval of the Division of Energy, Mineral, and Land Resources. The Division of Energy, Mineral, and Land Resources may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Resources, the Coastal Area Management Act, or any other federal or local government permit that may be required. �Nothing Compares----- SState of North Carolina I Environmental Quality I Energy, Mineral and Land Resources 512 N. Salisbury Street 11612 Mail Service Center I Raleigh. North Carolina 27699-1612 90 7079200 i If you have any questions concerning this permit, please contact Bethany Georgoulias at telephone number (919) 807-6372 or by email bethan ear oulias a ncdenr. ov. Sincerely, Original signed by B, Georgoirlias for Tracy E. Davis, P.E., CPM, Director Division of Energy, Mineral, and Land Resources cc: Asheville Regional Office Michelle Hedrich (michelle.hedrich e.com) Stormwater Program Files DWR Central Files Nothing Compares_ State of North Carolina f Environmental Quality I Energy, Mineral and Land Resources 512 N. Salisbury Street 1612 Mail Service Center I Raleigh. North Carolina 27699-1612 919 707 9200 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG030000 CERTIFICATE OF COVERAGE No. NCG030685 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Unison Engine Components is hereby authorized to discharge stormwater from a facility located at Unison Engine Components 502 Sweeten Creek Industrial Park Road Asheville Buncombe County to receiving waters designated as Sweeten Creek, a class C water in the French Broad River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, 11, III, and IV of General Permit No. NCG0�0000 as attached. This certificate of coverage shall become effective September 1, 2017. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this 15t day of September 2017. Original signed by R. Georgoulias for Tracy E. Davis, P.E., CPM Director, Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission LOCATION MAP: NCG030685 Map Stale 1. Z4, 000 Unison Engine Components Latitude: 3510 3V 55" N Longitude: 8211 31Y SS" W County: Bunaambe Receiving Stream: Sweeten Creek Stream Class: C index Number: 6-78-24 (French Broad River Basin) tt;•ma's :� ttc +*� i�a� Facility Location NCDM1ENR N brts� y.nQLW Vcrv.�iiNi�r Op ENvy1C�nl�T IHO Nd1N•L ftF1auwCL1 Division of Energy, Mineral and Land Resources Land Quality Section National Pollutant Discharge Elimination System NCG030000 5 ad d 00 0 FOR hGLNCY USE ONLY Daic Received Year Monai Da Certificate aFC ve N 0 3 Cli c A nount Pernnt Assn a to C' oft aou" 4 S NOTICE OF INTENT � RLS C/i [.'0zjy'S 5rL--p-" , National Pollutant Discharge Elimination System application for coverage under General Permit NCG030000: STORMWATER DISCHARGES associated with activities classified as: SIC (Standard Industrial Classification) 335 Rolling, Drawing, and Extruding of Nonferrous Metals SIC 3398 Metal Heat Treating SIC 34 Fabricated Metal Products SIC 35 Industrial and Commercial Machinery a•y l'� EIVI=[) SIC 36 Electronic and Other Electrical Equipment SIC 37 Transportation Equipment '��� ��jl SIC 313 Measuring, Analyzing, and Controlling Instruments DENR•ZANL) STORMWATER p RMlUAL iTY ,1 _l For questions, please contact the DEMLR Regional Office for your area. See page 4. (Please print or type) 1) Mailing address of ownerloperator (address to which all permit correspondence will be mailed): Name unison Engine Components yVY� f f��J r t { ^ M G1�t �^-t f�%i � 2 V' Street Address 502 Sweeten Creek Industrial Park Road _ `f City Asheville State NC ZIP Code 28803 Telephone No 829 232-8455 Fax, 2) Location of facility producing discharge: 3) Facility Name Unison Engine Components Facility Contact Michelle Hedrich Street Address 502 Sweeten Creek Industrial Park Road City Asheville State NC ZIP Code 28803 _ County Buncombe Telephone No. 829 232-8455 Fax: Email , Oichell(Cedrich@ge com Q Physical Location Information: M ; Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). From 140 take 25 Alt south for'/2 mile to Sweeten Creek Industrial Park Road. 502 is at the end of Sweeten Creek Industrial Park Road. (A copy of a county reap or USGS quad sheet with the fatality clearly located must be submitted wrath this application ) 4) Latitude 35 32' 55" /-87 30'58" (deg, min, sec) 5-A;3u�3 Page 1 of 4 SWU-218-071408 Last revised 7/2114 NCG030000 N.O.I. 5) This NPDES Permit Application applies to which of the following: ❑ New or Proposed Facility Date operation is to begin fflx'st�i 6) Standard Industrial Classification: Provide the 4-digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility. SIC Code: 3 7 2 4 7) Provide a brief narrative description of the types of industrial activities and products manufactured at this facility. Metal machining to produce aviation parts 8) Discharge points 1 Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater from the property? What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater discharges end up in? Sweeten Creek Receiving water classification Class_C Is this a 303(d) listed stream? No Has a TMDL been approved for this watershed? _No If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e g. City of Raleigh municipal storm sewer). NA 9) Does this facility have any other NPDES permits? ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: 10) Does this facility have any Non -Discharge permits (ex: recycle permit)? M ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 11) Does this facility employ any best management practices for stormwater control? ❑ No e (Show any structural SMPs on the site diagram.) tf yes, please briefly describe- All potential contaminates are covered. Only loading / unloading areas are exposed. 12) Does this facility have a Stormwater Pollution Prevention Plan? ❑ No Ye If yes, when was it implemented? June 14, 2017 13) Are vehicle maintenance activities occurring at this facility? 0_ � 14) Hazardous Waste: Page 2 of 4 SWU-218-071408 Last revised 712114 i NCG030000 N.O.I. a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? M ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg of hazardous waste generated per month) of hazardous waste? ® ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg or more of hazardous waste generated per month) of hazardous waste? ❑ Yes d) Is hazardous waste stored in the 100-year flood plain? M❑ Yes If yes, include information to demonstrate protection from flooding e) If you answered yes to questions b, or c , please provide the following information Type(s) of waste: How is material stored: Where is material stored How many disposal shipments per year: Name of transport 1 disposal vendor. - Vendor address: 15) Certification: North Carolina General Statute 143-215.613 (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article: or who knowingly makes a false statement of a material fact In a rulemaking proceeding or contested case under this Article, or who falsifies, tampers vnth, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000) I hereby request coverage under the referenced General Permit, I understand that coverage under this permit will constitute the permit requirements for the drscharge(s) and is enforceable in the same manner as an individual permit. I certify that 1 am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate Printed Name of Person Signing - Title: S 4e L-J r. (Signatu�caippficarlt) Co-IL-t7 (Date Signed) This Notice of Intent must be accompanied by a check or money order for $100.00, made payable to. NCDENR SWLJ-218-071408 Page 3 of 4 Last revised 712114 NCG030000 N.O.I. Final Checklist This application will be returned as incomplete unless all of the following items have been included: ❑ Check for $100 made payable to NCDENR. ❑ This completed application and all supporting documents ❑ A site diagram showing, at a minimum, (existing or proposed): (a) outline of drainage areas, (b) stormwater management structures, (c) location of stormwater outfalls corresponding to the drainage areas, (d) runoff conveyance features, (e) areas where materials are stored, (f) impervious areas, (g) site property lines. ❑ Copy of county map or USGS quad sheet with the location of the facility clearly marked on the map. Mail the entire package to: Stormwater Permitting Unit Program Division of Energy, Mineral and Land Resources 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Note The submission of this document does not guarantee coverage under the General Permit. For questions, please contact the DEMLR Regional Office for your area. DEMLR Regional Office Contact Information: Asheville Office-.,. . (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office . (704) 663-1699 Raleigh Office ....... (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ... . (336) 771-5000 Central Office ........(919) 807-6300 Page 4 of 4 SWU-218-071408 Last revised 712114 N 0 sr L100 Ft map provided by MyTopo.com f . w t oil AV 4-, t ,Jjj STORMWATER MWE DAM PLAN GNCA —AMGM t a 9 E3 GOODWYN I MILLS CAWOOD c- 10:3 FOR C..WCTIC M Z701 M A— I&L 35,W 1 Ta M B" 1�62 ==m