HomeMy WebLinkAboutNCG030666_MONITORING INFO_20190314STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO. /VCC�U�d���
DOC TYPE HISTORICAL FILE
H'MONITORING REPORTS
DOC DATE ❑ 0019 03 Iy
YYYYMMDD
March 6, 2019
Division of Water Quality
Attn DWQCentral Files
1617 Mail Service Center
Raleigh, NC 27699 1617
Re Stormwater Discharge Monitoring Report — 2019 Period 1
US Chemical Storage (Wilkesboro)
1806 River Street
Wilkesboro, NC 28697
Permit Number NCG030666
To Whom It May Concern
Please find enclosed the completed Semi -Annual Stormwater Discharge Monitoring Report for North
Carolina Division of Water Resources General Permit No NCGO30000 for US Chemical Storage, located
at the abovementioned address
If you have any questions or concerns, please feel free to contact Ben Sasamoto at (952) 567-5636
or via email at bsasamoto@uscompliance com
Sincerely,
Ben Sasamoto
Environmental Specialist II
=J
U S Compliance Corporation
o
cc Adrianne Brookshire, US Chemical Storage
Enclosures
r
U S Compliance Corporation
520 Thud Street . Suite 190 • Excelsior MN 55331 • Phone 952 252 3000 • Fax 952 252 3001
www ascomphance corn
Stormwater Discharge Monitoring Report
for North Carolina Division of Energy, Mineral and Land Resources General Permit No NCG030000
Date submitted 316/2019
CERTIFICATE OF COVERAGE NO NCG03 0 6 6 6
FACILITY NAME US Chemical Storage (Wilkesboro)
COUNTY Wilkes County
PERSON COLLECTING SAMPLES Adnanne Brookshire
LABORATORY pace Lab Cert q F-Ny375
Comments on sample collection or analysis
Part A Stormwater Benchmarks and Monitoring Results
SAMPLE COLLECTION YEAR 2018
SAMPLE PERIOD Q Jan -June ❑ July -Dec
or ❑ Monthly' tmorithl
DISCHARGING TO CLASS ❑ORW ❑HQW []Trout ❑PNA
❑Zero -flaw ❑Water Supply [:]SA
*Other vvs Iv
PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 -->
❑ No discharge this period a2
Outfall No
hate Sample
Collected'
(mo/dd/yr)
24 hour rainfall
amount,
Inches'
Total Suspended Solids
pH,
Standard units
Total Copper
Total Lead
Total Zinc
Non -Polar O&G/Tota!
Total Petroleum
Hydrocarbons
Toxic
organics;
Benchmarks
-
-
100 mg/L or 50 mg/0
6 0 — 9 0
0 010 mg/L
0 075 mg/L
0 126 mg/L
IS mg/L
1 mg/L
Parameter Code
-
46529
C0530
00400
01119
01051
01094
00552
78141
Outfall 01
2/12/2019
060
61 3
695
00152
<0 002
0 141
<1 51
N/A
1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall
'For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here
'The total precipitation must be recorded using data from an on -site rain gauge Unattended sites may be eligible for a waiver of the rain gauge requirement
° See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies
5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture
electronic crystals, or manufacture cathode ray tubes For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA
Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433 11, for semiconductor
manufacture use the definition as found in 40 CFR 469 12, for electronic crystal manufacture use the definition as found in 40 CFR 469 22, and for cathode ray
tube manufacture use the definition found in 40 CFR 469 31)
Permit pate 11/1/2018 05/31/2021 SWU 245, last revised 11/1/2018
Page 1 of 3
Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring
may be waived The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General
Permit For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement
Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics
(TTO), I certify that to the best of my knowledge and belief no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or
stormwater runoff has occurred since filing the last discharge monitoring report I further certify that this facility is implementing the all the provisions of the
solvent management plan included in the Stormwater Pollution Prevention Plan
Name (Print name)
Title (Print title)
Signature
Date
Note Results must be reported in numerical format Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non numerical
format When results are below the applicable limits, they must be reported in the format,_<XX me/L", where XX is the numerical value of the detection
limit, reporting limit, etc in mg/L
Note If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses See General Permit text
Part B Vehicle Maintenance Area Monitoring Results only for facilities averaging > SS gal of new oil per month
❑ No discharge this period Pz
Outfall No
Date Sample Collected'
(mo/dd/yr)
24 hour rainfall amount,
Inches3
New Motor Oil or
Hydraulic Oil Usage
Non Polar O&G/ Total
Petroleum Hydrocarbons
Total Suspended
Solids
Benchmarks
-
-
15 mg/L
100 mg/L or 50 mg/O
Parameter Code
-
46529
NCOIL
00552
C0530
Footnotes from Part A also apply to Part B
Note If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses See General Permit text
Permit Date 11/1/2018 05/31/2021 SWU 245, last revised 11/1/2018
Page 2 of 3
FOR PART A AND PART B MONITORING RESULTS
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS SEE PERMIT PART Il SECTION B
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS SEE PERMIT PART II SECTION B
• TIER 3 HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO [J
IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ❑ NO ❑
DEG'O^'AL OFFICE CO :'TACT dv; , 1E
Mail an oil, final copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end of monitoring period in the
case o "No Discharge" reports) to
Division of Water Quality
Attn DWQ Central Files
1617 Mail Service Center
Raleigh North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED
'I certify, under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information the information submitted is to the best of my knowledge and belief true accurate and complete
am awar that there are significant penalties for submitting false information including the possibility of fines and imprisonment for knowing violations
T "
/o) U S4//9
Signature of Permittee
Permit Date 11/1/2018 05/31/2021
Date
SWU-245 last revised 11/1/2018
Page 3 of 3
!L`