Loading...
HomeMy WebLinkAboutNCG030011_COMPLETE FILE - HISTORICAL_20150805STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /V C� b �j00 I 1 DOC TYPE t�HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ J)o 16 0 C� 5 YYYYMMDD AP r�`' AN WMENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor August 5, 2015 BorgWarner Emissions/Thermal Systems ATTN: Mr. Grover DeHart 40 Cane Creek Industrial Park Road Fletcher, North Carolina 28732 Donald R. van der Vaart Secretary SUBJECT: NPDES Stormwater Permit for BorgWarner EmissionsfThermal Systems General Permit No: NCG030000; COC No: NCG030011 Buncombe County Dear Mr. DeHart: In response to your questions regarding tiered responses according to your permit, NCDENR-Land Quality Section staff conducted a site inspection on July 1, 2015. The primary goal of this inspection was to evaluate compliance with the conditions of the NCG030000 General Permit, to discuss any actions that have been or could be taken to identify and limit potential sources of zinc and copper related to process operations. At the time of this inspection the facility was found to be in compliance with permit NCG030011 and no illicit discharges were discovered. Please keep in mind that benchmark exceedances are NOT limit violations or violations of permit conditions; however, you are obligated to follow the tiered response actions outlined in your permit. BorgWarner Emissions/Thermal Systems has been following the tiered response actions and therefore is in compliance with the permit. As part of tiered response, BorgWarner Emissions/Thermal Systems initiated housekeeping actions to reduce the zinc and copper levels and additional analytical monitoring to assess potential contributors, as documented in two reports from 2014 and 2015 provided during the inspection. Based on these actions and no finding of significant sources of zinc or copper related to processing at the facility, and upon receipt of this letter, BorgWarner Emissions/Thermal Systems may continue with the permit specified semi-annual analytical monitoring for the remainder of the current permit term. Your current permit is set to expire on October 31, 2017. This decision only applies to the zinc and copper benchmarks. A benchmark exceedance of any other parameter listed in your permit will trigger tiered response actions as described in the general permit. Division of Energy, Mineral, and Land Resources -- Land Quality Section Asheville Regional Office, 2090 US Highway 70, Swannanoa, North Carolina, 28778-8211 Telephone 828-296-4500 Fax 828-299-7043 ne hftp://Dortal.ncdenr.o[gtweblr4and-qqgliU We hCarohna An Equal Opportunity ! Affirmative Action Employer vIvatulpailly r p Mr. Grover DeHart August 5, 2015 Page 2 of 2 You must notify this office in writing, within five business days, if you become aware of any significant source of zinc or copper related to processing at your facility that has the potential to be exposed to stormwater. The relief, granted in this letter is contingent upon the current industrial practices at Borg Warner Emissions/Thermal Systems. If industrial practices change and zinc or copper become a significant stormwater exposure risk, then this office reserves the right to withdraw this decision and the permit specified tiered response or other actions may be warranted by the new set of circumstances. Please refer to the enclosed Compliance Inspection Report for additional comments, observations, and recommendations made during the inspection. Please retain and append this letter to your Stormwater Pollution Prevention Plan (SPPP) or permit.. If you have any questions or comments concerning this letter, please contact me at (828) 296-4500. Sincerely, , Darlene Kucken Environmental Specialist Enclosure ec: Bethany Georgoulias, RCO Compliance Inspection Report Permit: NCG030011 Effective: 11/01112 Expiration: 10/31117 owner: Borg Warner Cooling Systems SOC: Effective: Expiration: Facility: Borg Warner Cooling Systems County: Henderson Cane Creek Industrial Par Region: Asheville Fletcher NC 28732 Contact Person: Grover Dehart Title: Env.Specialist' Phone: 828-684-3501 Ext.128 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(*): Related Permits: Inspection Date: 07/0112015 Entry Time; 02:OOPM Primary inspector: Darlene J Kucken Secondary lnspector(s): Certtiication: Phone: Exit Time: 03:30PM Phone: Reason for inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Metal Fabrication Stormwater Discharge COC Facility Status: Compliant [] Not Compliant Question Areas: 0 Storm water (See attachment summary) Page: 1 permit: NCG0300 t 1 owner • Facility; Borg warner Cooling Systems Inspection Date: 0710112015 Inspection Type: Compliance Evaluation Reason for visit: Routine Inspection Summary: 1. This inspection was conducted by request of Grover DeHart to assess progress made towards assessing potential Zn and Cu nputs to stormwater from process activities as part of Tier I investigations and as a general stormwater permit compliance evaluation. 2. The following observations were made during the inspection: a. There are five pipes being assessed for potential Cu and Zn inputs to stormwater. These pipes are serving as a research study. b. Per the stormwater permit, there is one outfall that should be sampled as a measure of potential Inputs of Zn and Cu from process activities at the facility. This is called the "right pipe". Other pipes being sampled are not actual outfalls associated with processing and are only being sampled as part of the research study to determine potential inputs. c. It was noted during the inspection that the "center/main pipe/creek" had raw sewage in the flow at the time of inspection, This pipe is not considered to be representative of fhe facility process,activities and should not be sampled as the outfali sample. d. There is a galvanized roof that was installed last year and gutters were added within the last few months that could be contributing to Zn and Cu levels. 3. Current benchmark levels for Zn = 067mg/L and for Cu = .007mg/L. Upon permit renewal, these benchmark levels will be increased to ,Zn = ,126mg/L and Cu = .010mg1L. At current benchmark levels, the facility, Is below the benchmark for zn in the 2015 sampling of the "right pipe" (.048mg1l)and above the Cu benchmark (.023mgfL). 4 In addition to the five pipes assessed for the research study, the study also assessed the potential contributions of Zn from the air conditioner condensate water on the roof. The sampling showed high levels of Zn in the condensate water sample (.766, .477, .512, and .381 mg/L). it appears that the condensate water may be a contributor of Zn and further reseach on this contributor may be warranted if Zn and Cu benchmarks are exceeded such that Tier II sampling is required in the future. S. In summary, it appears that housekeeping has been assessed and Internal contributions to Zn and Cu are relatively non-existent; the reseach study has demonstrated Zn and Cu levels at several locations; the air conditioner condensate water has shown the highest levels of Zn; and Cu from the "right pipe" was above the benchmark in the 2015 sampling. 6. Semi-annual sampling of the "right pipe" should continue per permit conditions. Page: 2 Permit: NCG030011 ownar - Fecitity: Borth Wamer Cooling Systems tnspection Date: 07/01 /2015 Inspection Type: Compk anw Evaluation Raason for Vlatt: ROUtlne Stormwater Pollution Prevention Plan log No NA NE Does the site have a Stom'Fwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? 0 ❑ ❑ ❑ # Does the Plan Include a `Narrative Description of Practices"? M ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? M ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ 0 ❑ # Has the facility evaluated feasible altematives to current practices? 0 ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ ❑ ❑ # hoes the Plan include a Spill Prevention end Response Plan (SPRP)? ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 ❑ ❑ ❑ # Does the facility provide and document Employee Training? M ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ❑ Q Q # Is the Plan reviewed and updated annually? ■ ❑ ❑ ❑ # Does the Plan include a Stormwater Facility inspection Program?. ❑ ❑ ❑ Has the Slormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment: Qualitative Monitoring Yee No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? M ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? El - ❑ M ❑ Comment: Permit and Outfalls „s no NA NE # Is a copy of the Permit and the Certificate of Coverage avallable at the site? _I - ❑ ❑ ❑ # Were all outfalls observed during the Inspection? M ❑ ❑ ❑ # If the facility has representative outfatl status, is it properly documented by the Division? 0 ❑ 0 ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ 0 ❑ Comment: Page: 3 ALF� NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P. E. Governor Director December 4, 2012 ' Grover Dehart Borg Warner Cooling Systems PO Box 1509 Fletcher, NC 28732 Dee Freeman Secretary Subject: NPDES Stormwater Permit Coverage Renewal Borg Warner Cooling Systems CDC Number NCG030011 Henderson County Dear Permittee: In response to your renewal application for continued coverage under stormwater General Permit NCG030000 the Division of Water Quality (DWQ) is forwarding herewith the reissued General Permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated October 15, 2007 (or as subsequently amended). The following information is included with your permit package: • A new Certificate of Coverage (CDC) • A copy of General Permit NCG030000 • A copy of the Technical Bulletin for the General Permit • Two copies of the Discharge Monitoring Report (DMR) Form • Two copies of the Qualitative Monitoring Report Form The General Permit authorizes discharges of stormwater, and it specifies your obligations for discharge controls, management, monitoring, and record keeping. Please review the new permit to familiarize yourself with all the changes in the reissued permit. Your facility has six (6) months from the time of receipt of the permit to update your current SPPP to reflect all new permit requirements. The first sample period of your permit begins January 1, 2013. Your facility must sample a "measureable storm event" beginning during the periods beginning January 1 and July 1 of every year (or, if applicable, report "No Flow," as outlined in Part III, Section E). Also, please note that Tier 3 Actions in Part 11 of your permit are triggered by benchmark exceedances on four occasions beginning on the effective date of this permit and do not count prior exceedances. The more significant changes in the General Permit since your last CDC was issued are noted either in the Draft Permit Fact Sheet that accompanied the public notice (http://portal.ncdenr.org/web/wq/ws/su/current- notices), or in the Response to Comments / Summary of Changes and Technical Bulletin documents that are posted on the Stormwater Permitting Unit's website with the new General Permit. Please visit http://portal.ncdenr.org/web/wci/ws/su/npdessw (click on `General Permits' tab) to review that information for your specific General Permit carefully. 1617 Mail Service Center, Ralegh, North Carolina 27699-1617 Location: 512 N. Salisbury St Rateigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-6492 Internet: www.ncwaterguality.org None rthCarolina An Equal Opportunity 1 Affirmative Action Employer Grover Dehart 1' December 4, 2012 ` Page 2 of 2 Some of the changes include: Part II: • Section A: The Stormwater Pollution Prevention Plan (SPPP) section, if applicable, has been updated to the most current language of our permits. Additional conditions for specific industry sectors have been added to the SPPP requirements in some cases. • Sections B, C: Failure to perform analytical stormwater monitoring may result in the Division requiring that the permittee begin a monthly sampling scheme. • Sections B, C: A lower TSS benchmark of 50 mg/I for HQW, ORW, PNA and Tr Waters applies to these more sensitive waters. • Sections B, C. The monitoring parameter Oil & Grease (O&G) has been replaced by the parameter Total Petroleum Hydrocarbons (TPH) for vehicle maintenance areas, and in some cases, other analytical monitoring requirements. • Sections 8, C, D: Inability to sample due to adverse weather must be recorded in the SPPP, or in separate on -site records if your General Permit does not require an SPPP. Adverse weather is defined in the "Definitions" section of the permit. • Sections B, C: The term "Representative Storm Event" has been replaced by "Measurable Storm Event." A measurable storm event is defined in the permit. • Section D: If the permittee fails to respond effectively to problems identified by qualitative monitoring, DWQ may require the permittee to perform corrective action. Please review Parts III and IV to understand the Standard Conditions of your new NPDES General Permit, including Compliance and Liability, Reporting, Monitoring and Records requirements; Operation and Maintenance obligations; and Definitions. Please note that all samples analyzed in accordance with the terms of this permit must be submitted to the Division on Discharge Monitoring Report (DMR) forms available on the Stormwater Permitting Unit's website above. DMR forms must be delivered to the Division no later than 30 days from the date the facility receives the sampling results from the laboratory. Also note that existing permittees do not need to submit a renewal request prior to expiration unless directed by the Division. Your coverage under the General Permit is transferable only through the specific action of DWQ. This permit does not affect the legal requirements to obtain other permits which may be required by DENR, nor does it relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package, please contact the Division's Stormwater Permitting Unit at (919) 807-6300. Sincerely, I for Charles Wakild, P.E. cc: DWQ Central Files Stormwater Permitting Unit Files Asheville Regional Office STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG030000 CERTIFICATE OF COVERAGE No. NCG030011 STORMWATER NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Borg Warner Cooling Systems is hereby authorized to discharge stormwater from a facility located at: Borg Warner Cooling Systems Cane Creek Industrial Par Fletcher Henderson County to receiving waters designated as Hoopers Creek, a class C;Tr waterbody in the French Broad River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, II, 111, and IV of General Permit No. NCG030000 as attached. This certificate of coverage shall become effective December 4, 2012, This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this 41h day of December, 2012. for Charles Wakild, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality Asheville Regional Office SURFACE WATER PROTECTION March 28, 2008 Grover Dehart Borg Warner Cooling Systems Post Office Box 1509 Fletcher, NC 28732 Subject: NPDES Stormwater Permit Compliance Inspection Borg Warner Cooling Systems Permit No: NCG030011 Henderson County Dear Mr. DeHart: This letter is in follow-up to the NPDES Stormwater Permit Compliance Inspection conducted on March 17, 2008. The facility was found to be in compliance with permit NCG030011. Enclosed is a copy of the Compliance Inspection Report, which contains additional observations and comments for your reference_ Please contact me at (828) 296-4664 or chuck.cranford@ncmail.net if I can be of any further assistance. Sincerely, Chuck Cranford Enclosure cc: Central Files Asheville Files No ihCarolina Alaturally 2090 U.S. Highway 70, Swannanoa, NC 28778 Telephone: (828) 296-4500 Fax: (828) 299-7043 Customer Service 1 877 623-6748 G:IWPDATAIDEMWQ\Henderson\Stormwater Fabricated Metal NCG031BorgWarnerCE12008.dcc Compliance Inspection Report Permit: NCG030011 Effective: 11/01107 Expiration: 10/31/12 Owner: Borg Warner Cooling Systems SOC: Effective: Expiration: Facility: Borg Warner Cooling Systems County: Henderson Cane Creek Industrial Par Region: Asheville Fletcher NC 28732 Contact Person: Grover Dehart Title: Env.Speciaiist Phone: 828-689-3501 Ext.128 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Certification: Phone: Inspection Date: 03/17/2008 Entry Time: 09:30 AM Exit Time: 11:30 AM Primary Inspector: Chuck Cranford Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Stormwater Permit Inspection Type: Metal Fabrication Stormwater Discharge COC Facility Status. ■ Compliant n Not Compliant Question Areas: ® Storm Water {See attachment summary} Page: 1 Permit: NCG030011 Owner - Facility: Borg Warner Cooling Systems Inspection Date: 0311712008 Inspection Type: Stormwater Reason for Visit: Routine Inspection Summary: DWQ staff was met on site by Grover DeHart, environmental manager for the facility. A tour was conducted of both the exterior and interior of the building. During the visit, the SWPPP manual was reviewed, operational activities and possible stormwater exposure improvements were discussed as well as analytical monitoring requirements and results. The facility maintains IS014001 certification. Environmental management appears to be a priority for the permittee. Some stormwater exposure exists around the building exterior including: pallets, "clean" drums, used liquid containers, minimal metal chip waste and nylon pellets spillage. An item of concern is a stormwater sump located in a loading dock area where chemicals are off-loaded from trucks. The sump is emptied by a float -actuated pump which delivers the contents to the stormwater system. Mr. DeHart assured the inspector that all personnel including truck drivers are aware of an emergency cut-off switch located adjacent to the dock, which is to be selected if a spill into the sump occurs. Discussion took place regarding the Infall #1 sample results, which indicated that chemical contaminants have been found in the stormwater where it enters facility property. Continued sampling at Infall #1 seemed to be a wise approach to continue until and if the upstream source of the contamination can be identified and eliminated. Overall, the facility maintains good stormwater pollution prevention practices and compliance with the NCG03 permit. A No Exposure Certification (NEC) was discussed, but moderate to significant changes would have to occur to reach certification. DWQ staff would gladly discuss this opportunity further with the permittee. Page: 2 Permit: NCG03001 , Owner - Facility. Borg warner Cooling Systems Inspection Date: 03/17/2008 Inspection Type: Stormwater Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 9 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? n ❑ n # Does the Plan include a "Narrative Description of Practices"? n n n # Does the Plan include a detailed site map including outfall locations and drainage areas? ® 0 0 n # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ n # Has the facility evaluated feasible alternatives to current practices? ® n n n # Does the facility provide all necessary secondary containment? n n 0 0 # Does the Plan include a BMP summary? l! n rl # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ® n n n # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ® n n n # Does the facility provide and document Employee Training? n ® Q Q # Does the Plan include a list of Responsible Party(s)? n n n # Is the Plan reviewed and updated annually? ❑ E Q Q # Does the Plan include a Stormwater Facility Inspection Program? n n n Has the Stormwater Pollution Prevention Plan been implemented? ■ .n n n Comment: Documentation of annual plan review, SW facility inspection and employee training pertaining to SW was not documented in the manual. No chemicals are stored exterior to the building, therefore secondary containment is not required. Most areas of concern (AOC) have been rooted, eliminating SW exposure; however, several temporary storage areas of pallets, clean drums and empty liquid containers exist. Three loading docks were noted. One has a stormwater sump, which is emptied to the stormwater system via a float -activated pump. This sump could collect chemicals if a spill occured at the dock. The work area at the SE corner of the building has containers for metal waste, materials pallets, dumpsters and cardboard. A roof covers the majority of the equipment/materials minimizing exposure, but this is considered a minor AOC. Qualitative Monitorirtg Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ n n n Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ■ 0 ❑ 0 # Has the facility conducted its Analldical monitoring from Vphwr.],- Maintanance-arpas? n n Comment: First bi-annual monitoring sampling was conducted in February 2008. However, contractor failed to collect TSS, O&G and lead. Permittee intends to re -sample at next opportunity. Page: 3 Permit: NCGO30011 Owner -Facility: Borg Warner Cooling Systems Inspection Date: 03/17/2008 Inspection Type: Stormwater Reason for Visit: Routine Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ l=i # Were all outfalls observed during the. inspection? ■ n an # If the facility has representative outfall status, is it properly documented by the Division? ❑ G # Has the facility evaluated all illicit (non stormwater) discharges? ■ ❑ fn n Comment: Outfall #1 represents the confluence of 5 outlets. At this location, it appears a small creek has been piped through the site, which daylights at this confluence of SW outlets. Two drain from parking lot inlets, one drains a ditch S and SE of building, one apparently conveys a french drain system along back side of bldg. and one carries the stream along with SW from 2-3 inlets from parking areas. Page: 4 Michael F. Easley, Governor C O �� William G. Ross Jr., Secretary C I LE North Carolina Department of Environment and Natural Resources FILE Coleen H. Sullins, Director Division of Water Quality Asheville Regional Office SURFACE WATER PROTECTION March 28, 2008 Grover Dehart Borg Warner Cooling Systems Post Office Box 1509 Fletcher, NC 28732 Subject: NPDES Stormwater Permit Compliance Inspection Borg Warner Cooling Systems Permit No: NCG030011 Henderson County Dear Mr. DeHart: This letter is in follow-up to the NPDES Stormwater Permit Compliance Inspection conducted on March 17, 2008. The facility was found to be in compliance with permit NCG030011. Enclosed is a copy of the Compliance Inspection Report, which contains additional observations and comments for your reference_ Please contact me at (828) 296-4664 or chuck.cranford@ncmail.net if I can be of any further assistance. Sincerely, Lf Chuck Cranford Enclosure cc: Central Files / -Asheville Files NorthCarolina Naturally 2090 U.S. Highway 70, Swannanoa, NC 28778 Telephone: (828) 296-4500 Fax: (82B) 299-7043 Customer Service 1 877 623-6748 G:IWPDATAIDEMWQIHendersonlStormwater Fabricated Metal NCG03113orgWarnerCEl2008.doc Compliance Inspection Report Permit: NCG030011 Effective: 11/01/07 Expiration: 10/31/12 Owner: Borg Warner Cooling Systems SOC: Effective: Expiration: Facility: Borg Warner Cooling Systems County: Henderson Cane Creek Industrial Par Region: Asheville Fletcher NC 28732 Contact Person: Grover Dehart Title: Env.Specialisl Phone: 828-689-3501 Ext.128 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Certification: Phone: Inspection Date: 03/17/2008 Entry Time: 09:30 AM Exit Time: 11:30 AM Primary Inspector: Chuck Cranford Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Stormwater Permit Inspection Type: Metal Fabrication Stormwater Discharge COC Facility Status: ® Compliant n Not Compliant Question Areas: ® Storm Water (See attachment summary) Page: 1 Permit: NCG030011 Owner -Facility: Borg warner Cooling Systems Inspection Date: 03117/2008 Inspection Type: Stormwater Reason for Visit: Routine Inspection Summary: DWQ staff was met on site by Grover DeHart, environmental manager for the facility. A tour was conducted of both the exterior and interior of the building. During the visit, the SWPPP manual was reviewed, operational activities and possible stormwater exposure improvements were discussed as well as -analytical monitoring requirements and results. The facility maintains IS014001 certification. Environmental management appears to be a priority for the permittee. Some stormwater exposure exists around the building exterior including: pallets, "clean" drums, used liquid containers, minimal metal chip waste and nylon pellets spillage. An item of concern is a stormwater sump located in a loading dock area where chemicals are off-loaded from trucks. The sump is emptied by a float -actuated pump which delivers the contents to the stormwater system. Mr. DeHart assured the inspector that all personnel including truck drivers are aware of an emergency cut-off switch located adjacent to the dock, which is to be selected if a spill into the sump occurs. Discussion took place regarding the Infall #1 sample results, which indicated that chemical contaminants have been found in the stormwater where it enters facility property. Continued sampling at Infall #1 seemed to be a wise approach to continue until and if the upstream source of the contamination can be identified and eliminated. Overall, the facility maintains good stormwater pollution prevention practices and compliance with the NGG03 permit. A No Exposure Certification (NEC) was discussed, but moderate to significant changes would have to occur to reach certification. DWQ staff would gladly discuss this opportunity further with the permittee. Page: 2 Permit; NCGO30011 owner - Facility: Borg Warner Cooling Systems Inspection Date: 03/17/2008 Inspection Type: Stormwater Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? n Cl 0 In # Does the Plan include a "Narrative Description of Practices"? n n n # Does the Plan include a detailed site map including outfall locations and drainage areas? ® 0 ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? n n n # Has the facility evaluated feasible alternatives to current practices? # Does the facility provide all necessary secondary containment? L n ■ 0 # Does the Plan include a BMP summary? n n n ■ # Does the Plan include a Spill Prevention afid Response Plan (SPRP)? ■ 11 ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ n n ❑ # Does the facility provide and document Employee Training? ❑ ■ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ❑ ❑ n ■ # Is the Plan reviewed and updated annually? ❑ ■ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ❑ U ❑ ■ Has the Stormwater Pollution Prevention Plan been impiemented? ■ 0 t❑ ❑ Comment: Documentation of annual plan review, SW facility inspection and employee training pertaining to SW was not documented in the manual. No chemicals are stored exterior to the building, therefore secondary containment is not required. Most areas of concern (AOC) have been roofed, eliminating SW exposure; however, several temporary storage areas of pallets, clean drums and empty liquid containers exist. Three loading docks were noted. One has a stormwater sump, which is emptied to the stormwater system via a float -activated pump. This sump could collect chemicals if a spill occured at the dock. The work area at the SE corner of the building has containers for metal waste, materials pallets, dumpsters and cardboard. A roof covers the majority of the equipment/materials minimizing exposure, but this is considered a minor AOC. Qualitative Monitoring Yes No NA _NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ ❑ ❑ ❑ Comment: Anal ical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ■ ❑ ❑ ❑ #_Has the facility conducted its Analytical monitrring Comment: First bi-annual monitoring sampling was conducted in February 2008. However, contractor failed to collect TSS, O&G and lead. Permittee intends to re -sample at next opportunity. Page: 3 Permit: NGG030011 Owner - Facility: Borg Warner Cooling Systems Inspection Date: 03117/2008 Inspection Type: Stormwater Reason for Visit: Routine Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ■ 0 0 El # Were all outfalls observed during the inspection? ■ ❑ 0 0 # If the facility has representative outfall status, is it properly documented by the Division? n El m 0 # Has the facility evaluated all illicit (non stormwater) discharges? ■ Comment: Outfali #1 represents the confluence of 5 outlets. At this location, it appears a small creek has been piped through the site, which daylights at this confluence of SW outlets. Two drain from parking lot inlets, one drains a ditch S and SE of building, one apparently conveys a french drain system along back side of bldg. and one carries the stream along with SW from 2-3 inlets from parking areas. Page: 4 . 4 s Pace Analytical Services, Inc. Pace Analytical Services, Inc. acmnalytical 2225 Riverside Dr. 9800 Kincey Ave. Suite 10o wrwypacela6smm Asheville, NC 28804 Huntersville, NC 28078 (828)254-7176 (704)875-9092 ANALYTICAL RESULTS Project: Borg Warner TTO-Infall Pace Project No.: 9213064 Sample: INFALL Lab 10: 9213064001 Collected: 02/06/08 15:47 Received: 02106108 17:17 Matrix: Water Parameters Results Units Report Limit OF Prepared Analyzed CAS No. dual 608 GCS Pesticides and PCBs Analytical Method: EPA 608 Preparation Method: EPA 3535 Aldrin NO ug/L 0.050 1 02/11/08 00:00 02/22/08 09:23 309-00-2 alpha-BHC NO ug/L 0.050 1 02/11/08 00:00 02/22/08 09:23 319-84-6 beta-BHC NO ug/L 0.050 1 02111108 00:00 02/22/08 09:23 319-85-7 delta-BHC NO ug/L 0.050 1 02/11/08 00:00 02/22/08 09:23 319-86-8 gamma-BHC (Lindane) NO ug/L 0.050 1 02/11/08 00:00 02/22/08 09:23 58-89-9 Chlordane (Technical) NO ug/L 0.50 1 02/11/08 00:00 02/22/08 09:23 57-74-9 4,4'-DDD NO ug/L 0.050 1 02/11/08 00:00 02/22/O8 09:23 72-54-8 4,4'-DOE NO ug/L 0.050 1 02/11/08 00:00 02/22/08 09:23 72-55-9 4,4'-DDT NO ug1L 0.050 1 02 I1108 00:00 02122/08 09:23 50-29-3 Dieldrin NO ug/L 0.050 1 02111/08 00:00 02/22/08 09:23 60-57-1 Endosulfan I NO ug/L 0.050 1 02/11/08 00:00 02/22/08 09:23 959-98-8 Endosulfan II NO ug/L 0.050 1 02/11/08 00:00 02/22/08 09:23 33213-65-9 Endosulfan sulfate NO ug/L 0.050 1 02/11/08 00:00 02/22/08 09:23 1031-07-8 Endrin NO ug/L 0.050 1 02111/08 00:00 02/22/08 09:23 72-20-8 Endrin aldehyde NO ug/L 0.050 1 02/11/08 00:00 02122108 09:23 7421-93-4 Heptachlor NO ug/L 0.050 1 02/11/08 00:00 02122/08 09:23 76-44-8 Heptachlor epoxide NO ug/L 0.050 1 02/11/08 00:00 02/22/08 09:23 1024-57-3 PCB-1016 (Aroclor 1016) NO ug/L 1.0 1 02/11/08 00:00 02/22/08 09:23 12674-11-2 (Aroclor 1221) NO ug/L 1.0 1 02/11/08 00:00 02/22/08 09:23 11104-28-2 �/CB-1221 PCB-1232 (Aroclor 1232) ND ug/L 1.0 1 02/11/08 00:00 02/22/08 09:23 11141-16-5 PCB-1242 (Aroclor 1242) NO ug1L 1.0 1 02111/08 00:00 021221p8 09:23 53469-21-9 PCB-1248 (Aroclor 1248) NO ugiL 1.0 1 02/11/08 00:00 02/22108 09:23 12672-29-6 PCB-1254 (Aroclor 1254) NO ug/L 1.0 1 02/11/08 00:00 02/22/08 09:23 11097-69-1 PCB-1260 (Aroclor 1260) NO ug/L 1.0 1 02/11/08 00:00 02122/08 09:23 11096-82-5 Toxaphene ND ugiL 0.50 1 02/11108 00:00 02/22/08 09:23 8001-35.2 Tetrachloro-m-xylene (S) 73 % 20-110 1 02/11/08 00:00 02/22/08 09:23 877-09-8 Oecachlarobiphenyl (S) 76 % 20-138 1 02/11/08 00:00 02/22(08 09.23 2051-24-3 6010 MET ICP Analytical Method: EPA 6010 Preparation Method: EPA 3010 Antimony NO ug/L 5.0 1 0211210810:43 021i4/0819:02 7440-36-0 Arsenic NO ug/L 5.0 1 02/12/08 10:43 02/14/08 19:02 7440-38-2 Beryllium NO ug/L 1.0 1 02112/08 10:43 02114/0819:02 7440-41.7 Cadmium NO ug/L 1.0 1 02/12/08 10:43 02114/0819:02 7440-43-9 Chromium NO ug/L 5,0 1 02/12108 10:43 02/14/0819:02 7440-47.3 Copper 11.1 ug/L 5.0 1 02/12/08 10:43 02114/0819:02 7440-50-6 Lead 5.8 ug/L 5,0 1 02/12/08 10:43 02/1410819:02 7439-92.1 Nickel NO ug/L 5.0 1 02/12/08 10:43 02/1410819:02 7440-02-0 Selenium NO ug/L 10.0 1 02/12/08 10:43 0211410819:02 7782-49-2 Silver NO ug/L 5.0 1 02/12/08 10:43 02114/0819:02 7440-22-4 Thallium NO ug/L 10.0 1 02/12/08 10:43 02/14/0819:02 7440-28-0 Zinc 127 ug/L 10.0 1 02/12/08 10:43 02/14/0819:02 7440-66-6 7470 Mercury Analytical Method: EPA 7470 Preparation Method: EPA 7470 Mercury NO ug/L 0.20 1 02111/0812.-35 02112/0814:25 7439-97-6 Jate: 02/25/2008 01:07 PM REPORT OF LABORATORY ANALYSIS Page 3 of 22 This report shall not be reproduced, except in full, without the written consent of Pare Analytical Services, Inc.Pn - I J+ Pace Analytical Services, Inc. 2225 Riverside Dr. Asheville, NC 28804 Pace Analytical Services, Inc. 9000 Kincey Ave. Suite 130 Huntersville, NC 28078 aceAnalytical wcvw.pxefabs.com Project. Pace Project No.: Sample: INFALL 626 MSSV Borg Wamer TTD-Infall 9213064 Parameters Acenaphthene Acenaphthylene Anlhracene Benzo(a)anthracene Benzo(a)pyrene Benzo(k)fluoranthene Benzo(g,h,i)perylene Benzo(k)fluoranthene 4-Bromophenylphenyl ether Butylberizylphthalate 4-C hloro-3-methylphenol bis(2-Chtoroethoxy)methane bis(2-Chloroethyt) ether bis(2-Chlaroisopropyl) ether 2-Chloronaphthalene 2-Chlorophenol 4-Chiorophenylphenyl ether Chrysene ,3ibenz(a,h)anthracene 3,3'-Dichlorobenzidine 2,4-Dichiorophenol Diethylphthatate 2,4•Dimethylphenol Dimethylphthalate Di-n-butylphthalate 4,6-Dinitro-2-methylphenol 2,4-Dinitrophenol 2,4-Dinitrotoluene 2,6-Dinitrotoluene Di-n-oclylphthalate bis(2-Ethylhexyl)phthalate Fluoranthene Fluorene H exachl oro-1 ,3-butediene Hexachlorobenzene Hexachlorocyclo pentadiene Hexachloroethane Indeno(1,2,3-cd)pyrene Isophorene Naphthalene Nitrobenzene 2-Nitrophenol 4-Nltrophenol N-Nitrosodimethy]amine N-Nitroso-di-n-propylami ne N-Nitrosodiphenylamine Pentachlorophenol .,bate: 02/2512008 01:07 PM (6281254.7176 ANALYTICAL RESULTS Lab ID: 9213064001 Collected: 02/06/08 15:47 Received: 02/06/08 17:17 Matrix: Water Results Units Report Limit OF Prepared Analyzed CAS No. Analytical Method: EPA 625 Preparation Method: EPA 625 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04;02 83-32-9 NO uglL 5.9 1 02/13/08 00:00 02/18/08 04:02 208-96-8 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 120-12-7 NO ug/L 5.9 1 02/13/08 00:00 02118/08 04:02 56-55-3 NO ug/L 5.9 1 02M 3/08 00:00 02/18/08 04.02 50-32.8 N0 ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 205-99-2 N D ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 191-24-2 ND ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 207-06-9 ND ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 101-55-3 ND ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 85-68-7 ND ug/L 5.9 1 02/13/08 00:00 02/18108 04:02 59-50-7 NO ug/L 11.8 1 02/13/08 00:00 02/18106 04:02 111-91-1 ND ug/L 5.9 1 02/13/08 00:00 02118/08 04:02 111-44-4 NO ug/L 5.9 1 02/13108 00:00 02/18/08 04:02 108-60-1 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 91.58-7 NO ug/L 5.9 1 02/13/00 00:00 02/18/08 04:02 95-57-8 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 7005-72-3 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 218-01-9 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 53-70-3 ND ug/L 5.9 1 02/13/08 00:0D 02/18/08 04:02 91-94.1 NO ug/L 5.9 1 02113/08 00:00 02/18/08 04:02 120-83-2 NO ug/L 5.9 1 02113/08 00:00 02118/08 04:02 84-66-2 NO ug/L 11.8 t 02113108 00:00 02/18/08 04:02 105-67-9 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 131-11-3 NO ug/L 5.9 1 02113/08 00:00 02/18/08 04:02 84.74-2 NO ug/L 23.5 1 02/13/08 00:00 02/18/08 04:02 534-52-1 NO ug/L 58.6 1 02/13108 00:00 02/18/08 04:02 51-28-5 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 121-14-2 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 606-20-2 NO ug/L 5.9 1 02113/08 00:00 02/18/08 04:02 117-94-0 NO ug/L 5.9 1 02/13/08 00:00 02118108 04:02 117-81-7 NO ug/L 5.9 1 02/13108 00:00 02/18108 04:02 206-44-0 NO ug/L 5.9 1 02/13)08 00:00 02/18/08 04:02 86.73-7 NO ug/L 5.9 1 02/13108 00:00 02/18/08 04:02 87-68-3 NO ug/L 5.9 1 02113/08 00:00 02/18108 04:02 118-74-1 NO ug/L 11.8 1 02/13/08 00:00 02/18/08 04:02 77-47.4 NO ug/L 5.9 1 02113/08 00:00 02/18/08 04:02 67.72-1 NO ug/1- 5.9 1 02/13/08 00:00 02/18/08 04:02 193-39-5 NO ug/L 11.8 1 02113/08 00:00 02/18/08 04:02 78-59-1 NO ug/L 5.9 1 02/13/08 00:00 02/18108 04:02 91-20-3 NO ug/L 5.9 1 02/13/08 00:00 02118/08 04:02 98-95-3 NO uglL 5.9 1 02/13/08 00:00 02/18/08 04:02 88-75-5 NO ug/L 58.8 1 02/13/08 00:00 02/18/08 04:02 100-02-7 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 62-75-9 NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 621-64-7 NO ug/L 11.8 1 02/13/08 00:00 02/18/08 04:02 86-30-6 ND ug/L 29.4 1 02113/08 00:00 02/18/08 04:02 87.86-5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. ap� r �cCr (704)875 9092 Qua] Page 4 of 22 e Pace Analytical Services, Inc. Pace Analytical Services, Inc. alceAnaVical 2225 Riverside Dr. 9800 Kincey Ave. Suite 100 wwwpaoela6xcom Ashevifle, NC 28804 Huntersville, NC 28078 (828)254-7176 (704)875-9092 ANALYTICAL RESULTS Project: Borg Warder TTO-Infall Pace Project No.: 9213064 Sample; INFALL Parameters Lab ID: 9213064001 Results Units Collected: 02106/08 15A7 Report Limit DF Received: 02/06/08 17:17 Matrix: Water Prepared Analyzed CAS No. Qual 625 MSSV Analytical Method: EPA625 Preparation Method: EPA625 Phenanthrene NO uglL 5.9 1 02/13/08 00:00 02/10/08 04:02 85-01-8 Phenol NO ug/L 5.9 1 02/13/08 00:00 02/18/08 04:02 108-95-2 Pyrene NO ugiL 5.9 1 02/13/08 00:00 02/18108 04:02 125-00-0 1,2,4-Trichicrobenzene ND ug/L 5.9 1 02/13/08 00:00 02/18108 04:02 120-82-1 2,4,6-Tdchlorophenol NO ug/L 11.8 1 02/13/08 00:00 02/18/08 04:02 88-06-2 Nitrobenzene-d5 (S) 47 % 10-120 1 02/13/08 00:00 02/18/08 04:02 4165-60-0 2-Fluorobiphenyl (S) 56 % 15-120 1 02/13/08 00:00 02/18/08 04:02 321-60.8 Terphenyl-d14 (S) 68 % 11-131 1 02/13/08 00:00 02118/08 04:02 1718-51-0 Phenol-d6 (S) 18 % 10-120 1 02/13/08 00:00 02/18/08 04:02 13127-88-3 2-Fluorophenol (S) 26 % 10-120 1 02/13/08 00:00 02/18108 04:02 367-12-4 2,4,6-Tribromophenol (S) 64 % 10-137 1 02/13/08 00:00 02/18/08 04:02 118-79-6 624 Volatile Organics Analytical Method: EPA 624 Benzene NO ug1L 5.0 1 0211210811:56 71-43-2 Bromodichloromethane NO ug/L 5.0 1 02/1210811:56 75-27-4 Bromoform NO ug/L 5.0 1 02/12/08 11:56 75-25.2 Bromomethane NO uglL 10.0 1 0211210811:56 74-83-9 ',Carbon tetrachloride NO ug1L 5.0 1 02/12/08 11:56 56-23-5 ,-,Chlorobenzene NO ug1L 5.0 1 02112/08 11:56 108-90-7 Chlorcethane NO ug/L 10.0 1 02/12/08 11:56 75-00-3 Chloroform NO ug/L 5,0 1 02/12108 11:56 67-66-3 Chloromethane NO ug/L 5.0 1 02/12/08 11:56 74-87-3 Dibromochloromethene NO ug/L 5,0 1 0211210811:56 124-48-1 1,2-Dichlorobenzene NO ug/L 5.0 1 02/12/08 11:56 95-50-1 1,3-Dichlorobenzene NO ug1L 5.0 1 02/12/08 11:56 541-73-1 1,4-Dichlorobenzene NO ug/L 5.0 1 0211210811:56 106-46.7 1,1-Dichloroethane NO uglL 5.0 1 02112/0811:56 75-34-3 1,2-Dichloroethane NO ug/L 5.0 1 0211210811:56 107-06-2 1. 1 -Dichloroethene NO ug/L 6.0 1 02/12108li:56 75-35-4 cis- 1,2-Dichloroethene NO ug/L 5.0 1 02117JDB 11:56 156-59-2 trans-11,2-Dichloroethene ND ug/L 5.0 1 0211210811:56 156-60-5 1,2-Dichloropropane ND uglL 5.0 1 02 I210811:56 78-87-5 cis-1,3-Dichloropropene NO ug/L 5.0 1 02/12/0811:55 10061-01-5 trans-1,3-Dichloropropene NO ug/L 5.0 1 02112/0811:56 10061-02-6 Ethylbenzene NO ug/L 5.0 1 02/12/08 11 :56 100-41-4 Methylene Chloride ND ug/L 5.0 1 02/12/08 li:56 75-09-2 1.1,2,2-Tetrachioroethane NO ug/L 5.0 1 02/12/08 11:56 79-34.5 Tetrachloroethene NO ug1L 5.0 1 02112/08 11:56 127-18-4 Toluene NO ug1L 5.0 1 0211210811:56 108-88-3 1,1,1-Tiichooroethane ND ug/L 5.0 1 0211210811:56 71-55-6 1,1,2-Tdchloroethane ND ug/L 5.0 1 0211210811:56 79-00-5 Trichloroethene ND ug/L 5.0 1 02/12/08 11:56 79-Dl-6 Trichlorofluoromethane NO ug/L 10.0 1 02112/0B 11.56 75-69- 4 Vinyl chloride NO ug1L 5.0 1 02112/08 11:56 75-01.4 Dibromofluoromethane (S) 96 % 88-113 1 02/12/08 11:56 1868-53-7 4-Bromofluorobenzene (S) 102 % 86-111 1 02/12/08 11:56 460-00-4 Toluene-d8 (S) 99 % 92-105 1 02/12/08 11:56 2037-26-5 .-,Date: 02/25/2008 01:07 PM REPORT OF LABORATORY ANALYSIS Page 5 of 22 This report shall not be reproduced, except in MI, without the written consent of Pace Analytical Services, Inc.. ® Pace Analytical Services, Inc. aceAnaIXical 2225 Riverside Dr. www.pacrfa6s.com Asheville, NC 28804 (826)254-7176 ANALYTICAL RESULTS Project: Borg Warner TTO-Infall Pace Project No.: 9213064 Pace Analytical Services, Inc. 9800 KinceyAve. Suite 100 Hunteraviile, NC 28078 (704)875-9092 Sample: INFALL Lab I@: 9213064001 Collected: 02/06/08 15A7 Received: D2106108 17A7 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 624 Volatile Organics Analytical Method: EPA 624 1,2-Dichloroethane-d4 (S) 92 % 70-130 1 02/12/08 11:58 17060-07-0 420.4 Phenolics, Total Analytical Method: EPA420.4 Phenol 0.68 mg1L 0.020 2 02/08/08 21:11 108-95-2 450OCNE Cyanide, 'Total Analytical Method: SM 4500-CN-E Cyanide ND mglL 0.0050 1 02119/08 1128 57-12-5 _,Date: 02/25/2008 01:07 PM REPORT OF LABORATORY ANALYSIS This report shalt not be reproduced, except in full, without the written consent of Pace Analytical Services, inc.. GGGgo� • �s Page 6 of 22 L- 1 �_ Nov -5 2007 VVATER OUAUTY SECTION AS�;cVii LE r�G10 vAL 4FFIC! 1TWINRIM ff, October 8, 2007 d ) ( I Borg-Warner Cooling Systems P.Q. Box 1509�,�� . 40 Cane Creek Industrial Park Road Fletcher, North Carolina 28732 Attn: Mr. Grover Dehart Environmental Specialist Re: Quarterly Stormwater Sampling, Testing, and Reporting, North Carolina General Stormwater Permit Number NCG030000 BME Project No.: 215006 Dear Mr. Dehart: Borg Warner Cooling Systems of Fletcher, NC contracted Brooks Engineering Associates. PLLC (BEA) to conduct the annual stormwater sampling and reporting required by their General Stormwater Permit (Permit Number NCG030000). The following is a report of those activities. In accordance with the recommendations from the July I Id', 2007 sampling report, two samples were collected at the BorgWarner facility on September 146, 2007. A stormwater sample was taken at the first infall point to the subject property to monitor the quality of the stormwater that was coming from offsite_ The second sample was taken from the outfall from the BorgWarner contributing stormwater pipe located at Outfall No. 1. This outfall combines several drainage areas to combine flows at one point. All managed stormwater associated with Borg Warner's industrial facility is conveyed through Outfall t# I and discharged to Hooper's Creek. These two samples were compared to determine the origin of the non -compliant stormwater. SAMPLING ACTIVITIES The rain event occurred on September 14, 2007. Over the 24-hour period preceding the sampling date, 3.4004 inches of rain fell on the area (see Attachment 2). Grab samples were collected in accordance with EPA sampling guidelines as described in the DENR stormwater permit sampling requirements. Grab samples were on�ited into one pive sample of the event. Individual analyses are derived from the composite sample. Table 1 presents the analytical results of testing conducted on the composite sample collected at Infall ##1 and Outfall ## 1. Table 2 presents qualitative monitoring results of Infall 41 and Outfall # 1 during this storm event. The laboratory analytical report is contained in Attachment 3. Total flow was determined by an approximation calculation using the amount of rainfall on impervious sections of the facility site over the sampling period. It is assumed that the entire rainfall volume was captured and conveyed to the stormwater collection system. The total flow was calculated to be 0.938 million gallons over the course of the approximately twenty-four hours 17 Arlington Street Asheville, NC 28801 Phone: (828) 232-4700 Fax: (828) 232-1331 rw-7� FE'' r=• I preceding the sampling portion of the rainfall event. BEA's Environmental Technician, Kyle hoover, G.I.T., performed a qualitative evaluation of the stormwater. RESULTS The results of the sampling event are suntmari7ed in Tables I and 2 below. Table 1. Borg Warner -- Annual Stormwater AnalyticaI Monitoria g Results Total TotalOil and Sample ID Date Flow Lead pH Suspend ed Crease (MG) ( (mom-) m L Lab ID No.: 923703001 9-14-07 -- 0.0403 6.80 264 ND __(IN FALL #I Lab 1D No.: 923 703002 9-14-0 7 0.938 ND 6.80 2.4 ND OU41 rTFALL Pemit Limit — -- 0.033 6.0-9.0 100 30 Table 2. BormEWarner - Annual Stormwater Qualitative Monitoring Results Sample ID Floating Suspended Oil Other Color Odor Turbidi Solids Solids Foam Sheen Indicators Tan- None None None None None INFALL # l brown Noted Moderate Observed Heavy Noted Noted Noted OUTFAH-#I Clear None Slight None Slight None None None Noted I Observed Noted Noted I Noted The sampling results (shown in Table 1) show the Outfall 41 sample met all the requirements for a compliant stormwater discharge. The offsite stormwater sample (Infall #1) exceeded the general stormwater permit thresholds with a lead concentration of 0.0403 mg/L, and a TSS measurement of 264 mgfL. Site observations and photographs from the September 14`h stormwater sampling event (included as Attachment 4) illustrate the qualitative observations of a sediment laden stormwater discharge coming from the offsite stormwater pipe. The stormwater discharge from the BorgWarner site is shown to be treasonably clear, and is shown to be in contrast with the offsite stormwater discharge. Quantitatively, the stormwater analysis for the offsite contribution to Outfall No. I was found to be non -compliant. 17 Arlington Street Asheville, NC 28801 Phone: (828) 232-4700 Fax: (828) 232-1331 The stormwater analysis for the BorgWarner contribution Io the outfall at Hooper's Creek proved to be within the limits of the General Stormwater permit. Should you have questions regarding this report, }Tease contact us at (828) 232-4700. Sincerely, Brooks Engineering Associates, PLLC Mark C. Brooks, P.E. Senior Engineer 41 - Kyle Hoover, G.I.T. Environmental Associate Attachment I — Stormwater Flow Calculations Attachment 2 — National Weather Service Report Attachment 3 — laboratory Results Attachment 4 — Site Observation Photographs 17 Arlington Street Asheville, NC 28801 Phone: (828) 232-4700 Fax. {828} 232-1331 Pro ect: Borg Warner Stormwater Sampling Pm'ect #: 215006 Date: 9/14/2007 Star water Flow Calculation (Method, Total impervious area) Given Values: (1) Total Impervious Area:* 442.643 f#z (*Area determined by total impervious area noted in the Stormwater Management Plan) (2) Rainfall Amount:** 3.4 in. (" Rainfall amount includes the amount of rainfall over the 24 hour period preceding the sampling) Calculations 3.4 in, x 1 ft I x 1442,643 ft2 x 1 7.48 gal = 938,108 gal 12 in I 1 1 W 102,088 a x I 1 MG - 0.938 MG 1,000,000 gal m e a a Station: "VL - Asheville Regional Airport Date of first observation: January 1, 1948 Station type: ASOS - Standard City, State: Asheville, NC County: Buncombe County Latitude: 35.4361944" Longitude:-82.5418056° Elevation: 2165 feet above sea level Climate division: NC01 - Southern Mountains River basin: French Broad Supported by: NOAA National Weather Service This page is created dynamically and should not be bookmarked. Instead, bookmark the page preceeding this. Retrieving daily data from Asheville Regional Airport for past 90 day(s) 90 records found for this time period (100% data available) If you need more historical data from a larger period of record, please contact us for assistance This data set will be compiled from hourly observations. Missing and/or erroneous observations in the source data set will amplify errors with time in this data set Only minimal quality control methods have been applied. Use this data with caution! ci..J Date/Time of ob Q Number of daily SUM of Hourly Precipitation Records Compiled at 2m (in) 07/04/2007 24 (100°a) 07/05/2007 24 (1 w/o) 07/06/2007 24 (i00%) 0.0203 07/07/2007 24 (10m°/.) 07/08/2007 24 (1 o0%) 07/09/2007 24 (100%) 1.22 07/10/2007 23 (96%) 0.8803 07/1 1 /2007 24 (10()%) 0.1603 07/ 12/2007 24 (1000%) 07/13/2007 24 (100'/.) 0.0007 07/14/2007 24 (10(r/.) 07/ 1512007 24 (100%) 07/ 1612007 24 (t 00%) 0.0001 07/17/2007 23 (96%) 0.0205 07/ 1812007 24 (1 w/o) 0.0203 07/ 19/2007 24 (1009%) 0.2401 07/20/2007 24 (100 ,e) 0.0403 07/21 /2007 24 (100%) 07/22/2007 24 (1 W/o) 0.0002 07/23/2007 24 (100%) 0.0002 07/24/2007 24 (100%) 0.0204 07/25/2007 24 (100%) 0.8304 0726/2007 24 (100'/.) 0.0004 07/27/2007 23 (96%) 0.5102 /29/2007 )7/31/2007 )8/012007 )8/02/2007 )8/03/2007 )8/04/2007 )8/05/2007 )8/06/2007 )8/07/2007 )8/08/2007 )8/09/2007 )8/10i2007 )8/11/2007 )8/ 12/2007 )8/1312007 )8/14/2007 )8/15/2007 )8/16/2007 )8/ 17/2007 )8118/2007 )8/19/2007 )8/20/2007 )8/2112007 )8/2212007 24 (1om) 0.3702 24 (t00%) 0.2702 23 (96%) 0.2003 24 (100°/a) 24 (100°/a) 24 (100°/a) 24 (100a/a) 0.45 23 (96%) 24 (100%) 0.0001 24 (10(%) 24 (loom,) 13 (96%) 0.0101 24 (100a/a) 23 (96a/o) 24 (l00%) 24 (100%) 0.1202 24 (1oo°ia) 24 (10o%) 24 (100a/a) 24 (100°/a) 0.0101 24 (1 MI.) 24 (100%) 0.0001 24 (100%) 24 (100%) 24 (10(r) 0.1601 24 (1 WA) 24 (1 On.) 0.0003 24 (100o/o) 0.4702 24 (10U%) 0.0001 24 (l000/o) 0.2201 24 (100%) 21 (88%) 24 (1 o0a/o) 0.0001 24 (100alo) 1.4003 24 (1 o(a/o) 0.0002 24 (l 00a/o) 2 (8a/a) 1 5 (63%) 24 (100a/a) 24 (10(r) 24 (100%) 24 (100%) 24 (10(%) 24 (1 00%) 24 (1 ona) 24 (I 00o/a) 0.0001 09/ 12t2007 24 (100■>e) 09/130007 24 (10(r0) 09/14/2007 24 (1006A) 09/ 1 V2007 24 (1000/c.) 09/ 16/2007 24 (100%) 09/17/2007 24 (1000,0) 09/ 18/2007 8 (33%) 09/19/2007 18 (75%) 09/20/2007 23 (96%) 09/21 /2007 24 (1000.0) 09/22/2007 24 (1 oo /.) 09/23/2007 24 (100%) 09/24/2007 24 (100^ia) 09/25/2007 24 (1On.) 09/26/2007 23 (960/.) 09/27/2007 24 (100%) 09/28/2007 24 (1W/-) 09/29/2007 24 (100°!o) 09/30/2007 24 (100%) 10/01 /2007 24 (1000%) 3.4004 NC CRONOS Database version. 2.6.0 beta Query script last modified Sep 07, 2007 12:07:28 /�aceAnaVical. September 27, 2007 Mr. Mark Brooks Brooks & Medlock 17 Arlington Street Asheville, NC 28801 RE: Project: Borg Wamer 9114 Pace Project No.: 923703 Dear Mr. Brooks: Pace Anatyttcal Services, Inc. 2225 Riverside Dr, Ashamtte. NC 28804 (828)154-7176 Pace Analytical Services, Inc. 9800 Kmcey Ave. Suite 100 Huntersvitle, NC 28078 Enclosed are the analytical results for sample(s) received by the laboratory on September 14, 2007. The results relate only to the samples included in this report. Results reported herein conform to the most current NELAC standards, where applicable, unless otherwise narrated in the body of the report. Inorganic Wet Chemistry and Metals analyses were performed at our Pace Asheville laboratory and Organic testing was performed at our Pace Huntersville laboratory unless otherwise footnoted. All Microbiological analyses were performed at the laboratory where the samples were received. If you have any questions concerning this report, please feel free to contact me, Sincerely, Lord Patton loni.pafton@pacelabs.com Project Manager Enclosures oc: Mr. Kyle Hoover, Brooks & Medlock REPORT OF LABORATORY ANALYSIS This report shag not W mproduced. eroept in t41 without the written consent of Page Analytical Services, Inc. - (704)875.9092 Page 1 of 10 �_�acekialytical a Pate Analytical Services, Inc. Pace Analytical Services, Inc. 2225 Riverwe Dr. 6800 KinceyAve. Suite 100 www4ac iaCScUm Ashes NC 28804 rtunteravilte, NC 28079 (828)254-7176 (704)875-9092 Project Borg Warner 9114 Pace Project No.: 923703 Charlotte Certification lDs North Carolina Wastewater Certification Number: 12 North Carolina Field Services Certification Number. 5342 South Carolina Certification Number: 990060001 South Carolina Bioassay Certification Number: 990060003 Tennessee Certification Number. 04010 Asheville Certification IDs FloridafNELAP Certification Number. E87648 LouisianalLELAP Certification Number, 03095 New Jersey Certrficatien Number: NCO] i North Carolina Drinking Water Certification Number: 37712 North Carolina Wastewater Certifcabon Number: 40 North Carolina Bioassay Certification Number. 9 Eden Certification IDS North Carolina Drinking Wager Certification Number: 37738 Virginia Drinking Water Certification Number. 00424 CERTIFICATIONS Virginia Certification Number: 00213 Florida/NELAP Certification Number: E87627 Kansas Certification Number: E-10364 Louisianall.ELAP Certification Number. 04034 North Carolina Drinking Water Certification Number: 37706 Pennsytvania Certification Number. 68-03578 South Carolina Certification Number: 990300001 South Carolina Bioassay Certification Number. 990300002 Tennessee Certification Number: 2980 Virginia Certification Number: 00072 North Carolina Wastewater Certification Number. 633 REPORT OF LABORATORY ANALYSIS Page 2 of 10 Tht s report Shan not be reproduced. except in full, withorA the written consul of Pace Analytical Services. Inc . Paco Anatytical Services, Inc. Pace AnatyticaI Services, Inc. aceAnalytic ll 2225 Riverside 1]r. 9BOO Kincey Ave, Suite 1 OO •vrWyecekr"..s.con Asheville, NC 28804 Huntersvi5e, NC 28078 (828)254-7176 (704)875-9092 ANALYTICAL RESULTS Project: Borg Warner 9114 Pace Project No.: 923703 Sample: 1NFALL 1 Lab t€T: 923703001 Collected: 09/14107 13:45 Received: 09114107 15:22 Matrix: Water Parameters Results Units Report Limit OF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Anatytical Method: EPA 1664A Oil and Grease ND mg/L 5.0 1 09125/07 13:59 200.7 MET ICP Anatytical Method- EPA 200.7 Preparation Method'- EPA 200,7 Lead 40.3 ug/L 5.0 1 09/16107 16:00 09117/07 23:45 7439-92-1 25400 Total Suspended Solids Analytical Method: SM 2540D Total Suspended Solids 264 mg/L 4.3 1 09/10/07 07:16 4500H+ pH, Elactromotric Analytical Method; SM 4500-H+B PH at 25 Degrees C 6.8 Std. Units 1.0 1 09/17/07 21:10 H6 Date, 09/272007 01:02 PM REPORT OF LABORATORY ANALYSIS Page 3 of 10 This report shall not be repnaduoed. except in tul. without the written consent of Pace Anaty ml Services. Inc.. art aCaL Pace Analytical Services, Inc. Pace Analytical Services, Inc. /�aceAnalyticafo 2225 Riverside Dr. 980D KinceyAve. Suite 100 www4xtcetahs.0rr Ashevr9e. NC 288D4 Huntersville, NC 28078 (828)254-7176 (704)8759092 ANALYTICAL RESULTS Project: Borg Warner 9/14 Pace Project No.: 923703 Sample: OUTFALL 1 Lab ID: 923703002 Collected: 09/14/07 14:10 Received: 09/14/07 15:22 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, oil and Grease Anatytical Method: EPA 1664A Oil and Grease ND mg1L 5.0 1 09125M7 13:59 200.7 MET ICP Analytical Method: EPA 200.7 Preparation Method: EPA 200.7 Lead ND ug1L 5.0 1 09/18107 12:30 09/19/0717:14 7439-92-1 2540D Total Suspended Solids Analytical Method: SM 2540D Total Suspended Solids 2.4 mg1L 2.0 1 09/18/07 07:17 4500H+ PH, Electrometric Analytical Method: SM 4500-H+B PH at 25 Degrees C 6.8 Std. Units 1.0 1 09/17/07 21:10 H6 Date: 09/27/2007 01:02 PM REPORT OF LABORATORY ANALYSIS Page 4 at 10 This report shag not be reproduced, except in f A, without the written consent of Pace Anatypcal Services, Inc.. BSc • Pace Analytical Services, Inc. Pete Analytical Services, Inc. _ _ ace Analytical 2225 Riverside Dr. 9800 Kinoey Ave. Suite 100 ! Asheville, NC 28804 Huntersville, NC 28078 i (828)254-7178 (784)875-9092 QUALITY CONTROL DATA Project: Borg Warner 9/14 Pace Project No.: 923703 QC Batch: MPRP/1179 Analysis Method: EPA200.7 OC Batch Method: EPA 200.7 Analysis Desefiption: 200.7 MET Associated Lab Samples: 923703001 METHOD BLANK- 16557 Associated lab Samples: 923703001 Parameter Units ug/L Lead tARORATORY CONTROL SAMPLE: 16558 Parameter Units Lead ug/L Blank Reporting Result Limit Qualifiers ND 5.0 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 500 530 106 85-115 MATRIX SPIKE SAMPLE: Parameter 16559 Units 92355=1 Result Spike MS MS % Rec Cone. Result % Rec Limits Qualifiers Lead ug/L 10.5 500 496 97 70-130 SAMPLE DUPLICATE: 15636 923693001 Dup Parameter Units Resufe Result RPD Qualifiers Lead ug/L ND HD 200 R1 Date: 09f27r2W 01;02 PM REPORT OF LABORATORY ANALYSIS This report shag not be reproduced, examt in fact, wittrout the written owment of Pace Analytical Services, Inc.. /te�r'~• ���--• i�f' eE6: Page 5 of 10 w Pace Analytical Services, Inc. Pace Analytical Services, Inc. lace Analy4ical 2225 Rrversice Dr. 9800 Kirx.7--yAve $U a 100 wowpaceaas_oorn AsheviZe, NC 28804 Hurdersvilte, NC 28075 r (828)254-7176 (704)875.9092 ProjecC Borg Warner 9114 Pace Project No.: 923703 OC Batch: WETt1428 QC Batch Method: SM 4500-H+B Associated Lab Samples.: 923703001, 923703002 SAMPLE DUPLICATE: 16590 Parameter Units pH at 25 Degrees C Std. Units QUALITY CONTROL DATA Analysis Method: SM 450D-H+8 Analysis Description_ 4500H+B pH 923703001 Dup Result Result RPD Qualifiers 6.8 6.8 0 H6 Date: W27l1fl07 01:02 PM REPORT OF LABORATORY ANALYSIS Page 6 of 10 Thm report shad not be mprowced, except in full, without the written eonsenntMt of Pace Anatytiral Services, Inc Pace Analytical Servkes, Inc. Pace Analytical Services, tnc. 11'-2.TeAnalytical" 2225 Rivemde Dr. 9800 Kincey Ave. Suite 100 ww».pncafatrsmm Asheville, NC 28804 Huntersvilte, NC 28078 11 (628)254-7176 (704)875-9092 QUALITY CONTROL DATA Project: Borg Warner 9/14 Pace Project No.: 923703 QC Batch: WETl1438 Analysis Method: SM 2540D QC Batch Method: SM 2540D Analysis Description: 2540D Total Suspended Solids Associated Lab Samples: 923703001, 923703002 METHOD BLANK: 16944 Associated Lab Samples: 923703001, 923703002 Blank Reporting Parameter Units Result Limit Qualifiers Total Suspended Solids mg/L ND 1.0 LABORATORY CONTROL SAMPLE: 16945 Sprite LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mg& 250 242 97 80-120 SAMPLE DUPLICATE: 16946 923650002 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg1L 18A 17.2 7 Date. 09f272007 01:02 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in W. without the written consent of Pace Analytical Services, Inc.. Page 7 of 10 b Pace Analytical Services, Inc. Pace Analytical Services, Inc. aceMalytical 2225 Riverside Dr. 9soo Kincey Ave. Suite 100 w,y,b&C0M Asheville. NC 28804 Huntersvilte, NC 28078 1 (628)254.7176 (704)875-9092 1 Project: Borg Warner 9114 Pace Project No.: 923703 QC Batch: MPRP/1190 QC Batch Method: EPA 200.7 Associated Lab Samples: 923703W2 METHOD BLANK: 17058 Associated Lab Samples: 923703002 Parameter Units Lead ug/L LABORATORY CONTROL SAMPLE: 17069 Parameter Units Lead ug/L QUALITY CONTROL DATA Analysis Method: EPA 200.7 Analysis Description: 200.7 MET Blank Reporting Result Limit Qualifiers ND 5.0 Spike LCS LCS % Rec Conc. Result % Ree Limits Qualifiers 500 521 104 85-115 MATRIX SPIKE SAMPLE: 17110 923704001 Spike MS MS % Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Lead uglL ND 500 411 82 70-130 SAMPLE DUPLICATE: 17111 Parameter Lead 923704002 Dup Units Result Result ug/L ND ND RPD Qualifiers 0 Date: 09/27/2007 01:02 PM REPORT OF LABORATORY ANALYSIS Page 8 of 10 This report shah nos be reproduced, except in tun, without the written consent of Pace Analytical Services. Inc.. �tI l�d�ti s Pace Analytical Services, Inc. Pace Analytical Services, Inc. aceAnalytical 2225 Rsverside Dr. 9B00 KinoeyAve. Suite 100 r AMQOW&0= AsheviUe. NC 28804 Hunte:3vilie, NC 26078 (829)254-7176 (7(A4 875-9092 QUALITY CONTROL DATA Project: Borg Wamer 9114 Pace Project No.: 923703 QC Batch: GCSV11279 Ana"is Method: EPA 1664A QC Batch Method: EPA 1664A Analysis Description: 1664 HEM, Oil and Grease Associated Lab Samples: 923703001, 923703002 METHOD BLANK 19797 Associated Lab Samples: 923703001, 923703002 Parameter Units Oil and Grease mg)l LABORATORY CONTROL SAMPLE & LCSD: 19798 Parameter Oil and Grease Units Blank Reporting Result Limit Qualifiers ND 50 19799 Spoke LCS LCSD LCS LCSD % Rec. Max Conc. Result Result % Rec % Rec Limits RPO RPO Qualfers 4G 36.7 37.7 92 94 78-114 3 30 Date: 0912-12007 01:02 PM REPORT OF LABORATORY ANALYSIS Page 9 of 10 This report shall not be reproduoed, except in hill, without the wntten oansem of Pace Analytical Services, Inc.. �ilP.,�C3Ci Pace Analytical Services, Inc. Pace Analytical Services, Inc. acemalXical a 2225 Riverside Dr, 9800 Kincey Ave, Suite 100 f N,W, C0M Asheville, NC 28804 Huntersvill% NC 28078 f (828)254-7176 (704)875-9092 QUALIFIERS Project: Borg Warner 9114 Pace Project No.: 923703 LF�;MJIi101 i- DF - Dilution Factor, if reported, represents the factor applied to the reported data due to changes in sample preparation, dilution of the sample aliquot, or moisture content. ND - Not Detected at or above adjusted reporting limit. J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. S - Surrogate 1,2-Dipheny1hydrazine (8270 listed analyte) decomposes to Azobenzene. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Catmdable. Pace Analytical is NELAP accredited. Contact your Pace PM for the current list of accredited anelytes. ANALYTE QUALIFIERS H6 Analysis initiated more than 15 minutes after sample collection. R1 RPD value was outside control limits. Date: 09rz7M7 01:02 PM REPORT OF LABORATORY ANALYSIS Page 10 of 10 This report shall not be reproduced, except in hill, wittrout the written consent of Pace Anal Services. Inc.. �C/_fQhc Figure 1: InfalI #1 into subject property from offsite stormwater system Figure 2: Outfall # 1: (from Left to right) subject property entrance drainage, offsite stormwater from Infall #1, subject property parking lot drainage Figure 3: Outfall of site drainage for subject property (combined outfall to Hooper Creek to right of picture) Figure 4: Combination of offsite and offite stormwater drainage at outfall to Hooper Creek 13 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT GENERAL PERM IT NO. NCGO30000 CERTTF"ICATF OF COVERAGE NO. NCG03 60 FACILITY NAME wOJ Cl oinCA e r Tk eIr ^a � � `a+ C V S PERSON COLLECTING 5 LE(S) K £ oo V e-T CERTIFIED LAIIORATORY(S) ♦ ,iCC l4rtal�$'� Cca ( Lab # 4449 Lab # Part A. Specific Monitoring Requirements SAMPLES COLLECTED DURING CALENDAR YEAR: ;Z00 -7 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY C tit C� C r Sow_ _ PHONE NO. Z6 & 8el — 3501 SIGNATURE OF PERMITTER OR DESIGNEE) By this signature, I certify that this report is accurate complete to the hest of my knowledge Outfall No. Date Sample Collected 50050 00530 00400 01051 00556 78141 Total Flow Total Suspended Solids PH Lead Oil and Grease Total Toxic Or anines' trio/dd/ MG mg/1 units m mo u ct 7 — a 4 v. 0g03 N u a Al Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? _ yes _no (if yes, complete Part $) Part S: Vehicle Maintenance Activity Monitoring Requirements Outfall No. Date Sample Collected 50050 00556 00530 00400 Total Flow Oil and Grease Total Suspended Solids PH New Motor Oil Usage mofddl MG m MgA unit gallmo STORM EVENT CHARACTERISTICS: Date 9 r 3 — 9//`{ z oe7 Total Event Precipitation (inches Event Duration (hours): aR (if more than one storm event was sampled) Date Total Event Precipitation (incites): Event Duration (hours): Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 SWU-245-120399 Page I of 2 STORMWATTa;R DISCHARGE OUl'FAI1L (SDO) MONITORING REPORT GENERAL PERMIT NO. NCG030000 SAMPLES COL f TCTIiD DURfNG CALI�NDAIt YrAR: 0 -0O 7 CERTTFICATE OF COVERAGE NO. NCG03 O O 1 (This monitoring report shall be received by the Division nu later than 30 days from t �� j the date the facility receives the sampling results from the laboratory.) 1,�ACILTTYNAME Roc 1NGflte%F 6,ed'Vr al 5 1 e COUNTY � C�nc�'�ssov- PERSON COLLECTING SAMPLEK(S) 'q I e LLO DVe -r MPt' Atom, Ni. (e CERTr IED LABORATORY(S) T�d Ce �:IA&yy js cc,. I Lab # 0 Lab # �a S 55 Y6 7� SIGNATURE Ol? PiRMI'1'TRE OR DESIGNEE) By this signature, I certify that this report is accurate complete to the best of my knowledge Part A: Specific Monitoring Requirements Outfall No. Date Sample Collected 50050 00530 00400 01051 00556 78141 Total Flow Total Suspended Solids pH Lead Oil and Grease Total Toxic Or anincs' molddl r MG nt 1l units m =Il mull n 11 6 R% 07 0, IOR Z/a0 6,90 0, 01,5 N7-' Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? _ yes i o (if yes, complete Part D) J ` Part B: Vehicle illaintenanee Activity Monitoring Requirements Outfall No. Date Sample Collected 50050 00556 00530 00400 Total Flow Oil and Grease Total Suspended Solids pl:1 New Motor Oil Usage -malddl MG mg/1 mg/1 unit gaurno STORM EVENT CHARACTERISTICS: Date 6 zY - 6�i5 R-0 ° 7 Total Event Precipitation (inches): �' 7 Event Duration (hours): --� t(— (if more than one storm event was sampled) Date Total Event Precipitation (inclies): 1Jvent Duration (hours): Mail Original and one copy to: Division of Water Quality Attn: Central files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 SWU-245-120399 Page 1 of 2 V STORMWA'MR WSCLIARGE OUTFALL (SDO) MONITORING REPORT GENERAL PERMIT NO. NCG030000 SAMPLES COLLEC"rED DURLNG CALENDAR V AR: -2007 CERTIFICATE OF COVERAGE NO. NCG03 D (This monitoring report shall be received by the Division no later than 30 days fronn the dale the facility receives the sampling results from the laboratory.) FACILITYNAME gor UDG1r41etr -tkC1rVKa1f( � Sfcwr.5 COUNTY --P�e d e'rsov-' PERSON COLLECUNG SAMPLE(S) K`( I i? 400ye ,f PHONE NO. (@ 2� 68 -5 of - CERTIMED LA BORATORY(S) _�n ct~ �lyi a I f i Co [ Lah #. 13 ! T y p �` �z Lai) # 9� 2-1 I SIGNATURE 01? PERi•I11-FEE OR DESIGNEE) By this signature, I certify that this report is accurate complete to the hest of my knowledge Part A: Specific Monitoring Requirements Outfall No. Date Sample Collected 50050 00530 00400 01051 00556 78141 'Total Flow Total Suspended Solids PH Lead Oil and Grease Total Toxic Or anlnes` mo/dd! r MG m /l writs ni/1 rug/1 U /1 3 7- 07 O, l B 32 6,0(0 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? : yes (if yes, complete Part B) '90 Part B: Vehicle Maintenance Activity Monitoring Requirements Outfali l�To. Date Sample Collected 50050 00556 00530 00400 `l'otai Flow Oil and Grease 'Total Suspcnded Solids p11 New Motor Oil Usage rinolddlyr MG Mgt] nt il unit gallmo STORIN EVENT CHARACTERISTICS; Bate I — 3/7, aoo7 Total l;vent Precipitation (incl es): �• 6 Event Duration (hours): 1— (if more than one storm event was sampled) Date Total Event Precipitation (inches): Event Duration (hours): Mail Original and one copy to: Division of Water Quality Attn: Central Files if 17 Mail Service Center kale'igh, North Carolina 27699-1617 SW U-245-120399 Page I of 2 STORMWATER DTSC1TAltGE OUTFALL (SDO) MONITORING REPORT GENERAL PERMIT NO. NCG030000 SAMPLES COLLECTED DURING CALENDAR YEAR: �? 0 D {. CERTMICATE OF COVERAGE NO. NCG03 0011 ghis monitoring report shall be received by the Division no later than 30 clays from the date the facility receives the sampling results from the laboratory.) FACTLITYNAMF, 4Vf� V)&ofVe� �e�'►+XaJ �g5f-tV'`S COUNTY. HCV1COCJ'S 0V1 _ PERSON COLLECTING SAIMPLE(S) � Od'je\r r Sr}rnPc. E � D PHONE NO. (ELi�)). C2 ey- 32j01 CERTIFIED LABORATORY(S) _ C ( T. Ga 1 Lab #_ Lan # Part A: Specific Monitoring Requirements SIGNATURE, OF PERMITTET OR DESIGNEE) By this signature, I certify that this report is accurate complete to the nest of my knowledge Outfali No. Date Sample Collected 50050 00530 00400 01051 1..ead 00556 Oil and Grease 78141 Total Toxic Or anines' Total Flow Total Suspended Solids 141 [ moldd/yr MG m II units i m ll m u A 1-2-0f 2 O•U55 2P 7, 57 �1 env i Does this facility perform Vehicle Maintenance Activities using, more than 55 gallons of new motor oil per month? —yes o (if yes, complete Part B) Part B: Vehicle Maintenance Activity Monitoring Requirements Outfall No. Date Sample Collected 50050 00556 00530 00400 Total Flow Oil and Grease Total Suspended Solids PH New Motor Oil Usa e moldd/yr MG m /1 m fl unit al/mo STORMI EVENT CIIARACITsRISTICS: Date /Y 29 " fz/l a00(v Total Event Precipitation (inches): 0 Event Duration (hours): _ALk i-5 , (if more than one storm event was sampled) Date Total Event Precipitation (inches): Event Duration (hours): Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 SWU-245-120399 Page 1 of 2 Borg Warner Turbo&Emissions 1849 Arden Telephone Engine Systems Brevard NC 828 684 4029 Group Road 28704 Fax 828 880 7474 July 25, 2007 N ®QIH1@I' � OMIMIA9lOnA Syd@If1A Laurie Moorhead North Carolina Department Environment & Natural Resources Division of Water Quality Surface Water Protection, Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Re: NOV-2007-PC-0307 Dear Ms. Moorhead: 7006 2150 0005 2454 5854 The repair construction on the storm drain and catch basins at our facility is complete. We have verified the condition in dry weather and during recent rainfalls and are confident the modifications have improved the previous conditions on the property. I have enclosed recent photographs of these repairs. We also invite you to the facility at your convenience to view the changes. We appreciate your assistance in working with our facility in maintaining compliance to our permits and legal obligations. Please feel free to contact me should you have any questions regarding the enclosed documentation or campus modifications. You may contact Jerry Reid or myself to view the site. My contact information is enclosed. Jerry Reid may be reached in his office at (828) 684-4169, cell phone (828) 775-1247, or through company email at ireid(Mborgwarner.com . Sincerely, L Foster -Morrow, CET—,-._ Environmental, Health and Safety Specialist ]r 3 > 3020077 '> WATER QUALITY' S Q ASIIEVILLE REGfONAL OFFICE Michael F, Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality August 23. 2002 RAY RAYMOND BORG WARNER COOLING SYSTEMS PO BOX 1509 FLETCHER, NC 28732 Subject: NPDES Stormwater Permit Renewal BORG WARNER COOLING SYSTEMS COC Number NCG030011 Henderson County Dear Permittee: In response to your renewal application for continued coverage under general permit NCG030000, the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983. The following information is included with your permit package: * A new Certificate of Coverage * A copy of General Stormwater Permit NCG030000 * A copy of the Analytical Monitoring Form (DMR) * A copy of a Technical Bulletin for the general permit Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance. of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact Bill Mills of the Central Office Stormwater and General Permits Emit at (919) 733-5083, ext. 548 Sincerely, -8" ell Bradley Bennett, Supervisor Stormwater and General Permits Unit cc: Central Files Stormwater & General Permits Unit Files Asheville Regional Office NM*A NR N. C. Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 Customer Service 1-800-623-7748 F VVIaTF Michael F. Easley. Governor OHO ��� William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources � Gregory J. Thorpe, Ph-D. Q Acting Director Division of Water Quality December 27, 2001 NANCY LAUGHTER BORG WARNER AUTOMOTIVE INCORPORATED PO BOX 1509 FLETCHER. NC 28732 Subject: NPDES Stormwater Permit Renewal BORG WARNER AUTOMOTIVE INCORPORATED COC Number NCG03001 1 Henderson County Dear Permittec: Your facility is currently covered for stormwater discharge under General Permit NCG030000. This permit expires on August 31, 2002. The Division staff is currently in the process of rewriting this permit and is scheduled to have the permit reissued by late summer of 2002. Once the permit is reissued, your facility would be eligible for continued coverage under the reissued permit. In order to assure your continued coverage under the general permit, you must apply to the Division of Water Quality (DWQ) for renewal of your permit coverage. To make this renewal process easier, we are informing you in advance that your permit will be expiring. Enclosed you will find a General Permit Coverage Renewal Application Form. The application must be completed and returned by March 4, 2002 in ordor to assure continued coverage under the general permit. Failure to request renewal within this time period may result in it civil assessment of at least $250.00. Larger penalties inav be assessed depending on the delinquency of the request. Discharge of stormwater from your facility without coverage under a valid stormwater NPDES permit would constitute a violation of NCGS 143-215.1 and could result in assessments of civil penalties of up to $10,000 per day. Please note that recent federal legislation has extended the "no exposure exclusion" to all operators of industrial facilities in any of the I 1 categories of "storm water discharges associated with industrial activity." (except construction activities)- If you feel your facility can certify a condition of "no exposure", i.e. the facilty industrial materials and operations are not exposed to stormwater, you can apply for the no exposure exclusion. For additional information contact the Central Office Stormwater Staff member listed below or check the Stortwater & General Permits Unit Web Site at http_//h2o.enr.slate.nc.us/su/storin%vater.html If the subject stormwater discharge to waters of the state has been terminated. please complete the enclosed Rescission Request Form. Mailing instructions are listed on the bottom of the form. You will be notified when the rescission process has been completed. If' you have any questions regarding the permit renewal procedures please contact .Tim Reid of the Asheville Regional Office at 828-251-6208 or Bill Mills of the Central Office Stormwater Unit at (919) 733-5083, ext. 548 Sincerely, Bradley Bennett, Supervisor Stormwater and General Permits Unit cc: Central files Asheville Regional Office INCDENR N, C, Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 Customer Service 1- 800-623-7748 State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director October 29, 1999 Mr. Randy Hart Borg-Warner Automotive, Inc. Post Office Box 1509 Fletcher, North Carolina 28732 e�� NCDENR Subject: Permit Modification -Name and Ownership Change Borg-Warner Automotive, Inc. Permit No. NCG030011 (formerly Eaton Corp. -Fluid Power Division) Henderson County Dear Mr. Hart: In accordance with your request received October 27, 1999, the Division is forwarding the subject permit. The changes in this permit are only with regard to a name and an ownership. All other terms and conditions in the original permit remain unchanged and in full effect. This permit modification is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U. S. Environmental Protection Agency dated December 6, 1983. This permit does not affect the legal requirement to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act, or any other Federal or Local government permit that may be required. If you have any questions concerning this permit, please contact Ms. Vanessa Wiggins at telephone number (919)733-5083, extension 520. Sincerely, ORIGINAL SIGNED BY WILLIAM C. MILLS Kerr T. Stevens cc: Central Files Asheville Regional Office, Water Quality Section CStormwater and -General -Permits -Unit— ] Point Source Compliance Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG030000 CERTIFICATE OF COVERAGE No. NCG030011 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Borg-Warner Automotive, Inc. is hereby authorized to discharge stormwater from a facility located at Borg-Warner Automotive, Inc. Cane Creek Industrial Park SR 1551, Mills Gap Road Fletcher, NC Henderson County to receiving waters designated as Hooper Creek in the French Broad River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV of General Permit No. NCG030" as attached. This Certificate of Coverage shall become effective October 29, 1999, This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day October 29, 1999. o WIt�IAMAL SC. MED SY Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission State of North Carolina Department of Environment, IT Health and Natural Resources Division of Water Quality 4 MJ.9yTA • James B. Hunt, Jr., Governor Wayne McDevitt, Secretary C) C " A. Preston Howard, Jr., P.E., Director G September 25, 1997 PHILLIP DELP EATON CORP - FLUID PWR DfV PO BOX 1509, CANE CREEK IND PK FLETCHER, NC 28732 Subject: Reissued Stormwater General Permit for Certificate of Coverage No. NCG030011 Henderson County Dear Permittee: In response to your renewal application for continued coverage under the subject permit, the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. The following information is included with your permit package: ■ A copy of the stormwater general permit. ■ A Stormwater Pollution Prevention Plan Certification Form. This form certifies that you have developed and implemented the Stormwater Pollution Prevention Plan (SPPP) required in your permit. This form must be completed and returned to the Division within 30 days of receipt of this letter. DO NOT send the SPPP with the signed form. ■ Five copies of Analytical Monitoring forms. ■ Five copies of Qualitative Monitoring forms. ■ A copy of a Technical Bulletin on the stormwater program with outlines program components and addresses frequently asked questions. ■ A corrected Certificate of Coverage if you indicated a name or address change on the Renewal Form returned to the Division. Your certificate of coverage is not transferable except after notice to DWQ. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DWQ or permits required by the Division of Land Resources, Division of Air Quality, Coastal Area Management Act or any other Federal or Local governmental permits that may be required. If you have any questions concerning this permit or other attached documents, please contact the Stormwater Group at telephone number (919) 733-5083 Sincerely, for ,! A. Preston Howard, Jr., P. E. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 9t9-733-0719 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management 512 North Salisbury Street - Raleigh, North Carolina 27604 James B. Hunt., Jr., Governor Jonathan B. Howes, Secretary April 30, 1993 D. Kent Ammerman Eaton Corporation P O Box 1509 Fletcher, NC 28732 A. Preston Howard, Jr., P. E. Director Subject: General Permit No. NCCY030000 Eaton Corporation, Fluid Power Operations COC NCG030011 Henderson County Dear Mr. Ammerman: In accordance with your application for discharge permit received on September 16, 1992, we are forwarding herewith the subject certificate of coverage to discharge under the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North -Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, this certificate of coverage shall be final and binding. Please take notice that this certificate of coverage is not transferable except after notice to the Division of Environmental Management. The Division of Environmental Management may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Mr. Bill Mills at telephone number 919n33- 5083. cc: Sincerely, OIR41 Signed By ,,,.,1aan H. Sullins A. Preston Howard, Jr., P.E. Asheville Regional Office Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer i STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT Hsi : _ 'Tiui►���`.hle�lAlIill I ` I � ►f I II STORMWATER DISCHARGES In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Eaton Corporation is hereby authorized to discharge stormwater from a facility located at Eaton Corporation, Fluid Power Operations Cane Creek Industrial Park SR 1551, Mills Gap Road Fletcher Henderson County to receiving waters designated as Hooper Creek in the French Broad River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, I1, III and IV of General Permit No. NCG030000 as attached. This certificate of coverage shall become effective April 30, 1993 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day April 30, 1993. Original Signed Coleen H Sullins ullirms A. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Commission ley 4J,7b v. 620 O I zcr l FACILITY R inr r� COUNTY APE..'-� �I �C�o3aall VIA pft Al kJ D8N pV//4 SUB BASIN b 4- 0 3 - LATTITUDE -3 5 41 o LD:`.TDE� SG'� TREA&I r S6_q__. •. ' _ DtA, R U-E CLASS EXPIRATION DATE 81,31197