Loading...
HomeMy WebLinkAboutSW5190902_Application_20191114DEMIR USIa ONLY Date Received Fee Paid Permit Number Applicable Rules: ❑ Coastal SW -1995 ❑ Coastal SW - 2008 ❑ Ph II - Post Construction (select all that apply) ❑ Non -Coastal SW- HQW/ORW Waters ❑ UniversaI Stormwater Management Plan ❑ Other WQ Mgmt PIan: State of North Carolina Department of Environment and Natural Resources Division of Energy, Mineral and Land Resources STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form imy be photocopied for use as an. original I. GENERAL INFORMATION 1. Project Name (subdivision, facility, or establishment name - should be consistent with project naive on plans, specifications, letters, operation and maintenance agreements, etc.): Ca tiveAire Expansion 2. Location of Project (street address): 305 Northbrook Drive City:Youngsville County:Franklin Zip:27596 3. Direction to project (from nearest major intersection): At intersection of Bert Winston Rd (SR 1133) and Northbrook Drive (SR 1970) head south for 3,300' and CaptiveAire Expansion Site location will be on left. 4. Latitude:36° 02' 56" N Longitude:78° 29' 02" W of the main entrance to the project. IL PERMIT INFORMATION: 1. a. Specify whether project is (check one): ®New ❑Modification ❑ Renewal w/ Modificationt tRenewals Tuith modifications also requires SIAU-102 - RenezvaI Application Form b.If this application is being submitted as the result of a modification to an existing permit, list the existing permit number , its issue date (if known) , and the status of construction: ❑Not Started ❑Partially Completed' [] Completed' *provide a designers certification 2. Specify the type of project (check one): ❑Low Density ®High Density ❑Drains to an Offsite Stormwater System ❑Other 3. If this application is being submitted as the result of a previously returned application or a Ietter from DEMLR requesting a state stormwater management permit application, list the stormwater project number, if assigned, and the previous name of the project, if different than currently proposed, 4. a. Additional Project Requirements (check applicable blanks; information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748): ❑CAMA Major ®Sedimentation/Erosion Control: 5.19 ac of Disturbed Area ❑NPDES Industrial Stormwater ❑404/401 Permit: Proposed Impacts b.If any of these permits have already been acquired please provide the Project Name, Project/Permit Number, issue date and the type of each permit: Is the project located within 5 miles of a public airport? ®No ❑Yes If yes, see S.L. 2012-200, Part VI; http://12ortal.ncdenr.org/web/Ir/rules-and-regulations Farm SWU-101 Version Oct, 31, 2013 Page 1 of III. CONTACT INFORMATION 1. a. Print Applicant / Signing Official's name and title (specifically the developer, property owner, lessee, designated government official, individual, etc. who owns the proiect): Applicant/ Orgarlization� -Y-c641J,-'Cy /Jl E 5Y.57-XP-7-', Signing Official & Title:Brandon Hafner b.Contact information for person listed in item 1a above: Street Address:4641 Paragon Park Road City:Ralei h State:NC Zip:27616 Mailing Address (if applicable):Same City: Phone: 919 882--2410 Email:brandoi-i.liafi-ier@cal2tiveaire.com State: Zip: Fax: _( ) NIA c. Please check the appropriate box. The applicant listed above is: ®The property owner (Skip to Contact Information, item 3a) ❑ Lessee* (Attach a copy of the lease agreement and complete Contact Information, item 2a and 2b below) ❑ Purchaser* (Attach a copy of the pending sales agreement and complete Contact Information, item 2a and 2b below) ❑ Developer* (Complete Contact Information, item 2a and 2b below.) 2. a. Print Property Owner's name and title below, if you are the lessee, purchaser or developer. (This is the person who owes the property that the project is located on): Property Owner/Organization: C,6.5 r1/C-5 k%Lzl-,K GE--- C Signing Official & Title: /20�e/ZT G.. 1-41D, D b. Contact information for person listed in item 2a above: Street Address: '�.�- --6PJ P-99RA r2:T) City:_ /�✓7��,�1� State: /i�C- Zip:_ a'7616 Mailing Address (if applicable): 5,*VC- City: Phone: Email: State: Fax: Zip: 3. a. (Optional) Print the name and title of another contact such as the project's construction supervisor or other person who can answer questions about the project: Other Contact Person/Organization: Signing Official & Title: b. Contact information for person listed in item 3a above: Mailing Address: City: Phone: Email: State: Zip: Fax: { ) 4. Local jurisdiction for building permits: Yours sville Point of Contact:Andrew Thomas Phone 9: f919 ) 925-3401 Form SWU-101 Version Oct. 31, 2013 Page 2 of 6 IV. PROJECT INFORMATION 1. In the space provided below, briefly summarize how the storm water runoff will be treated. The new building addition and a portion of the new impervious pavements shall be collected and discharged into the created wetland as shown in the plans. 2. a. If claiming vested rights, identify the supporting documents provided and the date they were approved: ❑ Approval of a Site Specific Development Plan or PUD Approval Date: ❑ Valid Building Permit Issued Date: ❑ Other: Date: b.If claiming vested rights, identify the regulation(s) the project has been designed in accordance with: ❑ Coastal SW -1995 ❑ Ph II - Post Construction 3. Stormwater runoff from this project drains to the Tar -Pam River basin. 4. Total Property Area: 6.85 acres 5. Total Coastal Wetlands Area: 0 acres 6. 'Total Surface Water Area: 0 acres 7. Total Property Area (4) - Total Coastal Wetlands Area (5) - Total Surface Water Area (6) = Total Project Area+: 6.85 acres Total project area shall be calculated to exclude the following: the normal pool of impounded structures, the area bettoeen the banks of stremlts and rivers, the area beloto the Normal High Water (NIIW) line or Mean High Water (MHW) line, and coastal zvetlarrds laiidtoard fi,otu the NHW (or MHW) line. The resultant project area is zrsed to calcldate overall percent built upop area (8UA). Non -coastal zvetlands larldzvard of the NHW (or MHW) line uiay be included in the total project area. 8. Project percent of impervious area: (Total Impervious Area / Total Project Area) X 100 = 65.0 % 9. How many drainage areas does the project have?l (For high density, count 1 for each proposed engineered stormwater BAP. For lozo density and other projects, use 1 for the whole properhj area) 10. Complete the following information for each drainage area identified in Project Information item 9. If there are more than four drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. Basin Information Drainage Area 1 Drainage Area _ Drainage Area Drainage Area Receiving Stream Name Brandy Creek Stream Class * B;NSW Stream Index Number * 28-29 Total Drainage Area (sf) 194,277 On -site Drainage Area (so 194,277 Off -site Drainage Area (so 0 Proposed Impervious Area** (sf) 123,710 % Im ervious Area** (total) 63.68% Impervious** Surface Area Drainage Area 1 Drainage Area _ Drainage Area Drainage Area On -site Buildings/Lots (so 72,000 On -site Streets (so 0 On -site Parking (so 51,530 On -site Sidewall<s (so 180 Other on -site (so 0 Future (so 0 Off -site (sf) 0 Existing BUA*** (sf) 0 Total (so: 1 123,710 * Streain CIass and Index Number can be detet7nin.ed at: http. portal.ticdeizr.org/ oebAvq&s/esri/classi cations W 111r erviorts area is defined as the built upoti area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. Form SWU-101 Version Oct. 31, 2013 Page 3 of 6 * Report only that apro€ nt of existing BUA that will remain after developinent. Do not report any existing BUA that is to be reproved and which will be replaced by new BUA. 11. How was the off -site impervious area listed above determined? Provide documentation. NIA Projects in Union County: Contact DEMLR Central Office staff to check if the project is located within a Threatened & Endangered Species watershed that may be subject to more stringent stormwater requirements as per 15A NCAC 02B .o600. V. SUPPLEMENT AND O&M FORMS The applicable state stormwater management permit supplement and operation and maintenance (O&M) forms must be submitted for each BMP specified for this project. The latest versions of the forms can be downloaded from htt portal.ncdenr.org/ Web/Wg/ws/su/b€it,p-manual. VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Energy, Mineral and Land Resources (DEMLR). A complete package includes all of the items listed below. A detailed application instruction sheet and BMP checklists are available from hap;ll no/web w /ws/sea/statesw/forms does. The complete application package should be submitted to the appropriate DEMLR Office. (The appropriate office may be found by locating project on the interactive online map at littp:/ /portal.nedenr.org/web/wu/ws/su maps.) Please indicate that the following required information have been provided by initialing in the space provided for each item. All original documents MUST be signed and initialed in blue ink. Download the latest versions for each submitted application package from httV).JJo� rtal.ncdenr.or T %A,eb/wo/ia,s su statesiv for€its does. Initials 1. Original and one copy of the Stormwater Management Permit Application Form. - 2. Original and one copy of the signed and notarized Deed Restrictions & Protective Covenants Form. (if required as per Part VII below) 3. Original of the applicable Supplement Form(s) (sealed signed and dated) and O&M �t1' agreement(s) for each BMP. _ 4. Permit application processing fee of $505 payable to NCDENR, (For an Express review, refer to http: j lwww.envhelp.org/pages/onestope�html for information on the Express program and the associated fees. Contact the appropriate regional office Express Permit Coordinator for additional information and to schedule the required application meeting.) 4� 5. A detailed narrative (one to two pages) describing the stormwater treatment/management for 6. A USGS map identifying the site location. If the receiving stream is reported as class SA or the receiving stream drains to class SA waters within 1/2 mile of the site boundary, include the Y2 mile radius on the map. _ 7. Sealed, signed and dated calculations (one copy). 8. Two sets of plans folded to 8.5" x 14" (sealed, signed, & dated), including: a. Development/Project name. b. Engineer and firm. c. Location map with named streets and NCSR numbers. d. Legend. e. North arrow. f. Scale. g. Revision number and dates. h. Identify all surface waters on the plans by delineating the normal pool elevation of impounded structures, the banks of streams and rivers, the MHW or NHW line of tidal waters, and any coastal wetlands landward of the MHW or NHW lines. • Delineate the vegetated buffer landward from the normal pool elevation of impounded structures, the banks of streams or rivers, and the MHW (or NHW) of tidal waters. L Dimensioned property/project boundary with bearings & distances. j. Site Layout with all BUA identified and dimensioned. k. Existing contours, proposed contours, spot elevations, finished floor elevations. 1. Details of roads, drainage features, collection systems, and stormwater control measures. m. Wetlands delineated, or a note on the plans that none exist. (Must be delineated by a qualified persona Provide documentation of qualifications and identify the person who made the determination on the plans. For€n S W [J-101 Version Oct. 31, 2013 Page 4 of 6 n. Existing drainage (including off --site), drainage easements, pipe sizes, runoff calculations. o. Drainage areas delineated (included in the main set of plans, not as a separate document). p. Vegetated buffers (where required). 9. Copy of any applicable soils report with the associated SHWT elevations (Please identify elevations in addition to depths) as well as a map of the boring locations with the existing elevations and boring logs. Include an 8.5"xll" copy of the NRCS County Soils map with the project area clearly delineated. For projects with infiltration BMPs, the report should also include the soil type, expected infiltration rate, and the method of determining the infiltration rate. (Infiltration Devices submitted to WiRO: Schedule a site visit for DEMLR to verify the SHWT prior to submittal, (910) 796-7378.) 10. A copy of the most current property deed. Deed book: 2052 Page No: 198 11. For corporations and limited liability corporations (LLC): Provide documentation from the NC Secretary of State or other official documentation, which supports the titles and positions held by the persons listed in Contact Information, item la, 2a, and/or 3a per 15A NCAC 2H.1003(e). The corporation or LLC must be listed as an active corporation in good standing with the NC Secretary of State, otherwise the application will be returned. http: / /www.secretary.state.nc.us/Corporations/ CSearch.aspx VII. DEED RESTRICTIONS AND PROTECTIVE COVENANTS For all subdivisions, outparcels, and future development, the appropriate property restrictions and protective covenants are required to be recorded prior to the sale of any lot. If lot sizes vary significantly or the proposed BUA allocations vary, a table listing each lot number, lot size, and the allowable built --upon area must be provided as an attachment to the completed and notarized deed restriction forte. The appropriate deed restrictions and protective covenants farms can be downloaded from http:llportal.nc�ienr,orgL\Icb/h/state stormwater-forms docs. Download the latest versions for each submittal. In the instances where the applicant is different than the property owner, it is the responsibility of the property owner to sign the deed restrictions and protective covenants form while the applicant is responsible for ensuring that the deed restrictions are recorded. By the notarized signature(s) below, the permit holder(s) certify that the recorded property restrictions and protective covenants for this project, if required, shall include all the items required in the permit and listed on the fortes available on the website, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the NC DEMLR, and that they will be recorded prior to the sale of any lot. VIII. CONSULTANT INFORMATION AND AUTHORIZATION Applicant: Complete this section if you wish to designate authority to another individual and / or firm (such as a consulting engineer and/or firm) so that they may provide information on your behalf for this project (such as addressing requests for additional information). Consulting Engineer:. Michael Stocks Consulting Firm: Stocks Engineering Mailing Address:P.O. Box 1108 City:Nashville State:NC Zip:27856 Phone: 252 459-8196 Fax: Email: kvarnell@stocksenOneering.com IX. PROPERTY OWNER AUTHORIZATION (if Contact Information, item 2 has been filled out, complete this section) 1, (print or type name of persona listed in Contact Information, item 2a) � Roaak i L , Lw>_ aY , certify that I own the property identified in this permit application, and thus give permission to (print or type name of person listed in Contact Information, item 1a) DPU4mr>o1v 1 i�FNER with (print or hjpe name of organization Iisted in Contact Information, item 1a) •I r-fv�.�lra S�t�r rats Jo develop the project as currently proposed. A copy of the lease agreement or pending property sales contract has been provided with the submittal, which indicates the party responsible for the operation and maintenance of the stormwater system. Dorm S W U-101 Version Oct. 31, 2013 Page 5 of 6 As the legal property owner I acknowledge, understand, and agree by my signature below, that if any designated agent (entity listed in Contact Information, item 1) dissolves their company and/or cancels or defaults on their lease agreement, or pending sale, responsibility for compliance with the DEMLR Stormwater permit reverts back to me, the property owner. As the property owner, it is my responsibility to notify DEMLR immediately and submit a completed Name/Ownership Change Form within 30 days; otherwise I will be operating a stormwater treatment facility without a valid perritit. I understand that the operation of a stormwater treatment facility without a valid permit is a violation of NC General Statue 143-215.1 and may result in appropriat cement action inclu ' the assessment of civil penalties of up to $25,000 per day, pursuant to N 143- b. Signature: Date:�119 I, V 1C U QUI C _ a Notary Public for the State of din `moo IU\,Q.� County of 9- , do hereby certify that "Lswj c�� personally appeared before me this -- day of v 10 (( and ac oi wledge th : ue execution of the application for p a stormwater permit. Witness my hand and official seal, �C �0 FARE PUB1-1C /E/Ir iCs���� X. APPLICANT'S CERTIFICATION SEAL My commission expires, 10 1 1, {print or ijpe name of person listed in Contact Information, itean 1a) Brandon Habier certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of the applicable stormwater rules under 15A NCAC 2H .1000 and any other applicable state stormwater requirements. Signature:- Dao`� Date: � 3 o2Da I 1, ' 4 n a Notary Public for the State of E >j"f t ' County of do hereby certify that personally appeared before me this`' day of S.Q � �/ ! and aq iowl dge the ue execution of the application for a stormwater permit. Witness my hand and official seal, r/ NOTARY PUBLIC SEAL My commission expiresc Form SWU-101 Version Oct. 31, 2013 Page 6 of 6