Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20160800 Ver 2_Construction Drawings_R2_20191111
FROM CHARLOTTE OFFICE: START OUT GOING SOUTHWEST ON RESEARCH DRIVE TOWARDS HARRIS BLVD. FOR 0.3 MILE; TURN LEFT ONTO W. WT HARRIS BLVD. I NC-24-E. FOR 0.4 MILE; TURN LEFT ONTO THE 1-85 N RAMP. FOR 0.3 MILE; MERGE ONTO 1-85 N. FOR 2.0 MILE; TAKE EXIT 48 FOR 1-485 TOWARD ROCK HILL. FOR 0.2 MILE; KEEP LEFT AT THE FORK AND MERGE ONTO 1-48511-485 OUTER. FOR 13.6 MILE; TAKE EXIT 16 FOR NORTH CAROLINA 161BROOKSHIRE BLVD TOWARD NEWTON. FOR 0.4 MILE; TURN RIGHT ONTO NC-16 NIBROOKSHIRE BLVD (SIGNS FOR NEWTON/NC-16 N) CONTINUE TO FOLLOW NC-16 N. FOR 14.9 MILE; TURN RIGHT ONTO ST JAMES CHURCH ROAD. FOR 1.2 MILE; TURN LEFT ONTO NC-16 BUSINESS N. FOR 1.7 MILE; TURN RIGHT ONTO GRASSY CREEK ROAD. FOR 1.4 MILE; TURN LEFT ONTO BUMBLEBEE LANE. FOR 0.3 MILE; DESTINATION WILL BE ON THE LEFT. DRIVING DIRECTIONS veri on,/ 8921 RESEARCH DRIVE CHARLOTTE, NC 28262 GRASSY CREEK SITE ADDRESS 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY LATITUDE: 35' 33' 44.9" N LONGITUDE: 81° 02' 33.1" W TAX/PIN #: 369601257238 ZONING: R-40 MUNICIPALITY: CATAWBA COUNTY STATE: NORTH CAROLINA TOWER TYPE: MONOPOLE TOWER TOWER HEIGHT: 117- (120- TO HIGHEST APPURTENANCE) NUMBER OF CARRIERS: 0 EXISTING, 1 PROPOSED USE: PROPOSED TELECOMMUNICATIONS TOWER AND UNMANNED EQUIPMENT CONSULTANT KIMLEY-HORN AND ASSOCIATES, INC. 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GEORGIA 30092 PHONE: (678) 533-3928 ATTN.: KEITH MARKLAND PROJECT SUMMARY DEVELOPER VERIZON WIRELESS 8921 RESEARCH DRIVE CHARLOTTE, NC 28262 PHONE: (704) 577-8785 ATTN: MICHAEL HAVEN POWER COMPANY ENERGY UNITED PHONE: (800) 522-3793 ATTN.: CUSTOMER SERVICE TELEPHONE COMPANY AT&T PHONE: (800) 288-2020 ATTN.: CUSTOMER SERVICE PROPERTY OWNER ELLIOTT & LOUNETTE FORBES-ROBINSON 7118 VINEWOOD ROAD SHERRILLS FORD, NC 28673 PHONE: (704) 483-3857 ATTN.: ELLIOTT FORBES-ROBINSON CONTACTS NOTE: SITE IS LOCATED WITHIN FEMA FLOOD MAP AREA 3710369600J DATED 09/05/2007 WITHIN FLOOD ZONE X AND ZONE AE. SHEET DESMPMON RM T1 COVER SHEET 2 T2 APPENDIX B: BUILDING CODE SUMMARY 0 SITE SURVEY (SHEET 1 OF 2) 0 SITE SURVEY (SHEET 2 OF 3) 0 SITE SURVEY (SHEET 3 OF 3) 0 N1 GENERAL NOTES 0 Cl OVERALL SITE PLAN 0 C2 SITE PLAN 0 C3 EQUIPMENT PAD LAYOUT 0 C4 EQUIPMENT PAD FOUNDATION SECTION DETAILS 0 C5 EQUIPMENT PAD FOUNDATION SECTION DETAILS 0 C6 FENCE, GATE, AND COMPOUND DETAILS 0 C7 GRADING AND EROSION CONTROL PLAN 1 OF 6 0 C8 GRADING AND EROSION CONTROL PLAN 2 OF 6 0 C9 GRADING AND EROSION CONTROL PLAN 3 OF 6 0 C10 GRADING AND EROSION CONTROL PLAN 4 OF 6 0 C11 GRADING AND EROSION CONTROL PLAN 5 OF 6 0 C12 GRADING AND EROSION CONTROL PLAN 6 OF 6 0 C13 GRADING AND EROSION CONTROL DETAILS 0 C14 BOX CULVERT PLAN 0 C15 BOX CULVERT DETAILS 0 C16 ACCESS ROAD DETAILS 0 C17 SITE SIGNAGE DETAILS 0 C18 WAVEGUIDE BRIDGE DETAILS 0 C19 ANTENNA AND TOWER ELEVATION DETAILS 0 C20 TEMPORARY STREAM DIVERSION 0 E1 BASIC SERVICE ROUTING PLAN 1 E2 GROUNDING PLAN 1 E3 SINGLE -LINE DIAGRAM 1 E4 ELECTRICAL DETAILS 1 E5 ELECTRICAL DETAILS 1 E6 ELECTRICAL DETAILS 1 E7 ELECTRICAL DETAILS 1 E8 ELECTRICAL DETAILS 2 E9 ELECTRICAL DETAILS 1 E10 ELECTRICAL DETAILS 1 E11 ELECTRICAL DETAILS 1 SHEET INDEX CATAWVA COUNTY PLANNING & PARKS DEPT. 100 A SW BOULEVARD NEWTON, NC 28658 PHONE: (828) 465-8381 ATTN.: SUSAN BALLBACH PERMIT INFORMATION verizon't' 8821 RESEARCH DRIVE CHARLOTTE. NORTH CAROLINA 28262 ROJECT INFORMATION: VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY URRENT ISSUE DATE: 07/21 / 16 SSUED FOR: CONSTRUCTION EV. —DATE:SSUED FOR: —BY: 0 0 ONSULTANT: ICimlelyno Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770—B25-0744 WWW.KIMLEY—HORN.COM NC License F-0102 ONSULTANT. RAWN BY:�HK.:APV.: CKMP KRM WCE CENSER: ESS • L = :� • 0 Z� HEET TITLE COVER SHEET HEET NUMBER: —REVISION• T1 2 018985035 6/20/16 CONSTRUCTION WCE 1 07/14/16 CONSTRUCTION WCE 2 07/21/16 CONSTRUCTION WCE l A anaum.nt, tVMW WM tM •MWpt• aW d"VM Pr ted h"n, a. m M-UU ant .f -la., I. Int.MM ony for th..p.af purpa.. and dint for whkh It . pnpand. R. of and knpmp.r Mann. an tht. do nt rldaut •'1d.n MtarhaU. and adaptt. by laml y—H— and A..dd k kro hdl h• .flhout Iabft to KMy—H— and Mw kbk Yee. Copyrlpht KImMW—Ekm and ApoehM, Im, 2016 2012 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES (Reproduce the following data on the building plans sheet I or 2) Name ufrrojecc VERIZON WIRELESS - GRASSY CREEK Address: 4747 GRASSY CREEK ROAD, DENVER, NC Zip Cede 28037 Proposed Use: WIRELESS COMMUNICATION SERVICES Owner/ApermizedAgent: KEITH MARKLAND Phone x(678 ) 533 - 3928 E-Mad kelth.maldmd Owned By: ❑ City/County ® Private ❑ Stat9ftley-hom.- Code Enforcement Jurisdiction: ❑ City ® ComltyCATAWBA ❑ Slate LEAD DESIGN PROFESSIONAL: XAWAM C. EDMONSON, P.E. (0041745) DESIGNER FIRM NAME LICLNSLN TELLPHONL4 E-MAIL Architectural Civil OW-1001 III AMIX IMAM c WEDMONSON D41745 �)201-8156 cdt�w Electrical APOGEE CON9,ILTNG COFMN NAROY 040M (%9 1�-7421) dodlrappt>al Fire Alarm (_) Plumbing (_) Mechanical (� Sprinkler -Standpipe (_) Stmctural (_) Rchiming Walls>5' High (_) Other _) 2012 EDITION GENIC CODE FOR: X New Cons'buctimn ❑ Addition ❑ Upfit EXISTING: ❑ Reconstruction ❑ Alteration ❑ Repair ❑ Renovation CONSTRUCFED:(datc) ORIGINAL USE(S) (Ch.3): TELECOMMUNICATIONS SITE RENOVATED: (date) CURRENT USE(S) (Cb-3): TELECOMMUNICATIONS SITE PROPOSED USE(S) (Ch.3): TELECOMMUNICATIONS SITE BASIC BUILDING DATA Construction Type: ❑ I -A ❑ II -A ❑ 11I-A ❑ N ❑ V-A (check all that apply) ❑ I-B ❑ ❑-B ❑ III-B ❑ V-B Sprinklers: ❑ No ❑ Partial ❑ Yes ❑ NITA 13 ❑ NFPA I-,R ❑ NFPA 13D Standpipes: ❑ No ❑ Yes Class ❑ I ❑ ❑ ❑ III ❑ Wet ❑ Dry Fire District: ❑ No ❑ Yes (Primary) Flood Hazard Area: ❑ No es Building Height: (feet) Gross Building Arco: FLOOR Ext-G (SOFT) NEewLSO Fr) SUH-TOTAL Floor Fluor Floor ALLOWABLE AREA Occupancy: .Assembly ❑ A-1 ❑ A-2 ❑ A-3 ❑ A-4 ❑ A-5 Business ❑ Educational ❑ Factory ❑ F-1 Moderate ❑ F-2 Low 1-lazard- El11-1 Detonate El H-2 Deflagrate E] H-3 Combust E]11-4 Hmlih ElH-5 HP lnsiilutiunal ❑ 1-1 ❑ 1-2 ❑ 1-3 ❑ 1-4 1-3 Condition El El El El El ?'4"co file ❑ Residential ❑ R-1 ElR-2 ElR-3 ElR-t Storage E]S-1 Moderate ❑ S-2 Low ❑ High -piled ❑ Parking Garage ❑ Op. ❑ Enclosed ❑ Repair Garage Utility and Miscellaneous ❑ Aecessory Oceuponcies: Assembly ❑ A -I ❑ A-2 ❑ A-3 ❑ A4 ❑ A-5 Business ❑ Educational ❑ Factory ❑ F-I Moderate ❑ F-2 Low Hazardous ❑ H-I Detonate ❑ H-2 Deflxerate ❑ H-3 Combust H-4 Health El HPM Insfimdonal El1-1 El2 El1-3 Ell-t 1-3 Condition E]I El El3 El4 El 5 bl"camilc ❑ Residential ElR-1 ElR-2 El R 3 ElRA storage ❑ S-I Moderate ❑ S-2 Low ❑ igh-piled ❑ Parking Garage ❑ Op. ❑ Encl. Repair Garage Utility and Miscellaneous ❑ Ineide.ul Uses (Table 508.2.5): ❑ Fumace room where any pie,, of equipment is p � r 40R000 Btu per hour input ❑ Rooms writh boilers where the largest piece Of uipment is Dyer 15 psi and 10 borsepo\wer ❑ Refrigerant machine room ❑ Hydrogen cutoffrooms. not classified as ' cup H ❑ lacinemmr rooms ❑ Paint shops, not classified as Group , located in Occupancies other than Group F ❑ Laboratories and vocational shops, of classified as Group H. located in a Group E or 1-2 Occupancy ❑ Laundry rooms over 100 square et ❑Grow 1-3 cells equipped With a ded surfa es ❑ Group I-2 waste and linen c lection rooms ❑ Waste and linen wllectio rooms over 100 square feet El Stationary storage ban systems having a liquid electrolyte capacity ofmoo, than 50 gallons, or a lithium- ioncapacity of 1,000 ounds used for facility standby power, emergency power or imintermpted power supplies ❑Roomscommini firepuntps ❑ Group I-2 stor ge rooms Over 100 square feet ❑ Group 1-2 c rintercial kitchens ❑ Group 1-7 aundries equal to or less than 100 square feet ❑ Group 2 onus or spaces that contain fuel -fired heating equipment Special Use ❑ 402 ❑ 403 ❑ 404 ❑ 405 ❑ 406 ❑ 407 ❑ 408 ❑ 409 ❑ 410 ❑ 411 ❑ 412 ❑41 ❑414 ❑415 ❑416 0417 ❑419 ❑419 ❑420 0421 ❑422 ❑423❑424 1-1_5 ❑ 426 ❑ 427 Spiel Provisions: ❑ 309.2 ❑ 509.3 ❑ 509.4 ❑ 5095 ❑ 509.6 ❑ 509.7 ❑ M9.8 ❑ 509.9 hlixcd Occupancy: ❑ No ❑ Yes Separation: Hr. Exception: ❑ Incidental Use Separation (508.2.5) This separation is not exempt as a Non-Sepamted Use (see exceptions). ❑ Non -Separated Use (508.3) The required type of construction for the building shall be determined by applying the Neigh d area limitations for each ofthe applicable occupancies to the entire building. The most resole' e type of construction, so ddmnined, shall apply to the entire building. ❑ Separated Use (508.A) - See below for arm caledations For each story, the arm ofthe occupancy shall be such that the samm of the ratios the actual floor area of each use divided bythe allowable floor area for each use shall not exceed 1. Ael IIArea nfOccaaaan• A + Aerrlal Areu a'OecumnrrB <i (1/mmble Area of Oera pan v A A!lounhle Area gfdeaupan B - + ...... - < L00 A STORYNO. DESUtmtoN AND USE (A) san-A STORY (A-) (D) TAOLE503. AREA (C) A1tG FOR LROtrTAGE INCREASEI (D) RN'CREASEr (E) ALID\VABLa AREAUR UNLIMIrEDr (F) -1141)M BUILDING ' Fronmge area inLTcasca from SectiO 06.2 arc computed thus: Perimeter which fronts a p lie way or open space having 20 feet minimum width = (F) It. Tool Building Pcrimet - (P) d. W=Minimum w% of public Way = (W) Pereento of Dun ge inerease lr= 100 I F/P - 0.25] x RC90 = (90) ' The sprinkler inere a per Section 506.3 is as follows: a. Multi-sto building I,=200percent b. Single orybuilding4=300pereent ' Unlimited ea applicable under conditions ufSectiun 507. 4 Maxim Building Area= total number ofstories in the building x E (506.4). The aximum arm ofopcn Parking garages must comply with Table 406.3.5. The maximum arm ofair traffic can of towers must comply with Table 412.1 .2. ALLOWABLE HEIGHT ALDOw F. 111CREASF FORSPRINI;LERS (TAxtr:503) sHO\l•N ONP CODE RFrExFascE Type ufC.asmmlen Type _ Type Building Bert in Feet IF- =H+20- B Id gilcightl Storic,,I FIRE PROTECTION REQUIREMENTS RUDERATING sEPARATION ms-E. FEET nRQ'p ( /nO a F Ox)} -1-4 AND snEET t{ .-N# MTF.n Ass.." ru-s'I%FOR HAl'!a PENETRATIO- ' -il Ica. xATFD ao1N'rs Snuctmal Froi., including columns, girders. Hearing Wank E ue Nadh Easy wear Smah Inmrinr N.A.6ng \\'ills and rmridans E.mrior w�na Nnnh �u wen slam Imcm,r anus and P,naians Floor cn -ii,n IncllJing sVrpaning brynls andjii,tz Raofcmmm du Imluding suproming tram. djaiku Shay Ensloknrek-E.a Shan rndnNrek-Goer ca,ddar se, rot oc<n :me,\sewmrion Pa dFirc will "iHaiar sakcymS ee, pnmm LIFE SAFETYSYSTEAI REQUIREMENTS Emergency Lighting: ❑ NO h Exit Signs: ❑ NO h Fire Aleut: ❑ NO Smoke Detection Systems: O [IYes El Partial Panic Haydn, -' ❑ NO ❑ Yes LIFE SAFETY PLAN REQUIREMENTS Life Safety Plan Sheet 9: �I r ❑ F'ire and/or smoke rated wall locations (Ch `�- ❑ Assumed d I pro en • . cations E]Exterm �n real arm with respect to distance to assumed property lines (705.8) ❑ Existing sWctmcs within 30' ofthe proposed budding ❑ Occupancy types for each area as it relairs to occupant load calculation (fable 10 ..1) ❑ Occupant loads for each arm ❑ Exit access travel distanccs(1016) P ❑ Common path ofuavcl distances (1014.3 & 1028.8) �\ ❑ Dead end lengths (1018.4) ❑ Clear exit widths for each exit it... ❑ Maximum calculated occupant load capacity each ex' oar can accommodate based on egress width (1005.1) ❑ Actual occupant load for each exit door ❑ A separate schematic plan indicating where, c rated floor/ceiling and/or mol'structure is provided for purposes ofooeupuncy separation ❑ Location of doors with panic had rc (1008.1.10) ❑ Location ofdoors with delay gross locks and the amount ofdeliy (1008. 1.9.7) ❑ Location ofdoors with e Iromagnetic egress locks (1008.1.9.9) ❑ Location ofdoors e pped with hold -open deices ❑ Location ofe y m c., pe windows (1029) ❑ The squar omge oferch fire arm (902) ❑ The s are (outage ofeach smoke compannment (407.4) ❑ e any code exceptions or table notes that may have been utilized regarding the items above ACCESSIBLE DWELLING UNITS (SECTION 1107) I'mr- A-S.I£ ALCEssmre 1NY6 T1TFA T] F YI'EB TOTAL UN- UNITS UNITS Ul�� UN NITS DNIT$ ACCESSIBLE UNITS REQUIRED PROVIDED REQ oemiso REQUIRED PimVIDED OVIOED ACCESSIBLE PARKING (SECTION 1106) I OF OIt PARKING OTALk m'PAII%ING SPACFS 7F OF ACCESsmrS SYACPS PAOVmED TOTAL" .AREA 1tEQU1REn t'ItOwnDm _AR w'IrH 5' ccrss F VAN SPACES wrim .132"A[(Fss cCE55 AISLE Ess"O, TROVmEn TOTAL ENERGY SUMMARY ENERGY REQUIREMENTS: The following data shall be considered minimum and any special attribute required to ncet the energy code shall also be provided. Each Desimer shall banish the require portions of the project information for the plan data Acet. Ifperformance method, state the annual energy cost for the standard reference de/"nalnffyct for the proposed design. Climate Zone: ❑ 3 ❑ 4 ❑ 5 Method of Compliance: ❑ Prescriptive (Energy Cade) ❑ Performance (Energy Code) ❑ Prescriptive (ASI IRAE 90.1) ❑ Performance (ASHRAE 90.1) THERMAL ENVELOPE Roof/ceiling Assembly (each assembly) Description of assembly. U-Value ftotal assembly: R-Value of insulation: Skylights in each assembly: U-Value ofskylight: total square footage ofskyligh in each assembly: Exterior Walls (mch assembly) Description ofassembly. U-Value oftotal usscan y: R-Value ofinsuhdion: Openings (windows r doors with ghaing) U-Value .ably. Salarhe gaincoeRcicnC prjmt n factor: Door -Values: Walls below grade - ch assembly) Descripti ofassembly U-Valu uflutal assembly: R-Vol eofinsulatmac _ Floors over mconditioned space (each assembly) caption ofassembly: -Value of mail assembly: R-Value of insulation: Flo s slab on grade Description ofassembly: U-Value of oral assembly R-Vnlne ofinsulation: Horizontal/vertical mquireamot: _. _..stab heated:. STRUCTURAL DESIGN DESIGN LOADS: Importance, Fact Wind (Ia) _..-.- ...... Snow pal Seismic (I') Live Loads: Roof psf Mezzanine list Floor psf Ground Snow Lard: psf Wind Load: Basic Wind Speed in (ASCE-7) Exposure Category Rind Banc Shears (tor MN' lax= vy= SEISMIC DESIGN CATEGORY; Xi9 ❑ B ❑ C ❑ D Provide die following Scismic Design Paramctms Occupancy Category (Table 1604.5)El11 El III E) iv Spectral Response Acceleration SsSI Site Classification (Table 161352) ❑ C ❑ D ❑•Ec El Data Source Field Test ElPresmnptbc E] Historical Data Basic structural system (check on ❑ Bearing Wall Dual w/Special Moment Frantic ❑ Building Frame ❑Dual wlIntermediate R/C or Special Steel ❑ Moment From ❑ lm•erted Pendulum Seismic bast shear: Y = VY = Analysis Proced/m., Simplified ❑ Equivalent Lateral Force ❑ Dynamic Architectural, MC......ents anchored? ❑ Yes ❑ No LATERAL DESIGN COEanlmgtlakc ❑ Wind ❑ SOIL BEARING CA ACITIES: Field Test (provide copy oftest report) _ Presumptive Bearing capacity Pile size, type, and capacity SPECIAL INSPECTIONS REQUIRED: ❑ Yes ❑ No PLUMBING FIXTURE REQUIREMENTS (TABLE 2902.1) e� ®.i--_- --- SPECIAL APPROVALS Special approval: (Local Jurisdiction, Department oflnsurnmee, OSC, DPI, D _ , etc., describe below) P __-... MECHANICAL SUMMARY MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT Thermal Zane winter dry bulb: summcrdrybulb: Interior design conditions vinmr dry both: summer dry bulb: relative humidity: Building beating load: Building cooling load: Mechanical Spacing Cond' oning Systcm Unitary coo' gaReiconcy: category ionic B cr leerrJ1� s Size eutceony. If oversize sole rmson. Chiller Size Size category. tfoverstzed, sole reason.: equipment efficiencies: ELECTRICAL SUMMARY ELECTRICAL. SYSTENI AND EQUIPMENT Method of Compliance: Energy Cade; ElPrescriptiveElPerformance ASHRAE 90.1: ❑ Prescriptive ❑ Perfonnunce Lighting schedule (each fixture hype) )amp type required in fixture �\ umber of lamps in fixture ballast type used in the fixture tuber ofballosts in fixmr total wattnuc per fistia total interior w^atom pecified vs. alloved (whole building or space by span) totalexleriorwa _especifiecivs.allowed Additional Presc ' live Compliance ❑ 5 2.1 More Efficient Mechanical Equipment SOG.2._> Reduced Lighting Purer Density 506.2.3 Energy Recovery Ventilation Systems ❑ M62.4 Higher Efficiency Service Water Heating ❑ 506.2.5 O'Site Supply of Renewable Energy El506.2.6 Automatic Daylighling Control Systems NOTE: SCOPE OF WORK INCLUDES INSTALLATION OF CAST IN PLACE CONCRETE PAD, PREFABRICATED EQUIPMENT CABINETS AND GENERATOR. verizon✓ 8821 RESEARCH DRIVE CHARLOTTE. NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY CURRENT ISSUE DATE: T� 06/20/16 �F CONSTRUCTION 0 06/20/16 CONSTRUCTION WCE ANI Kimley* Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-B25-0744 WWW.KIMLEY-HORN.COM NC License F-0102 DRAWN BY:=CHK.:APV.: I KMP I KRM I WCE errs I11ji, CARp r � :--5; • 0 1 45 Z= i '44 all AAr 04 APPENDIX B: BUILDING CODE SUMMARY T2 ° 018985035 .,,� ,..:,,,O..a..yrw� •�'n ,.. ,�,,,�r. �.. wyr� p�nua r,.r n, ,r, ,rwarr�.r a:.. mai- one .err raw .p.r.rc pap- ono - rar .yeti a A pr.P.- tau.. ar caw Impropr mane. W uv. aa-IM1 Wm at •mum amaruotlan OW odoptatbn by gmYy-tbtn and ApotlaOr, M. Mail be •M-d W6AIby to KM4y-Hom aM Auocioh•. kw. Capyrlpht lGank -Herat and A -dart... Ina., 201E ヽ ∠∠乞!_i/ / ノブ ̄ ̄ ̄」 /’ NC GRiD (NAD 83)三幸壬 Z二二千二三千イ「! I - ! ,もl「I-i-IIII′/′ /′′/、、、、-へへへ、「二/ 凸 ! o J 餌 i < ∴ : 歪○ し」」 」 ○ 0_ ▼ ̄ N 岬 寸 し(つ く○ 人、 音 臆臆 富 里 。喜。」 桑繭二 左2∽ 輔 口。くの ○ (二と 合○○ 之 。 之 言 霊 (⊃ 主〇〇 着酬虚 霊登呂 孟 8登 用腰 細∥酷 くの 霊室 。< 望 I ∥五′’ cらし1○○山 lll,′ ふ 。望 _∴誓書喜轟議 重 富 〔〕 < 誓重量喜 卜、 寸 、○ ア ̄ ̄ ̄ ̄ ̄毒薬---二軍 韓 筈」毒 ’’ 轟/’ 非情畠∴( 珊珊/′′/ 亡と ∪豊満喜寿責…毒 =) (二と そつ Cト 卜、 .- 、、o 、、o N 、○ 音 臆臆臆臆 < ㌢ N ㌢ 8 ° 洲 しくう o o 菓臆臆 藍Ig;l掴2掴?! 葛葛 Z NCGRiD(NAD83) 。 し山 > 0∠ 二) し) N (」 (ヽつ し) 寸 (」 lの し) ・○ し) 卜ヽ し) CO し) 、、 里 (」 」1」 トー く〔 ○ ○ 看獲臆臆1案 〃菓臆臆t葵 看臆園園畷獲音 山」 _」 〔n く〔 十一 コ= トー こう 三〇 そう 干、 N 葛 ト る○ :○ も く○ 寸 寸 °ヽ ぐう を〕 こ、 ⊂) 己 8 8 8 そう ⊂) わ 卜ヽ め 「ヽ し) Z 重さ 、〔:ビ くつ Z 車う (や の 軍事 寸 貧 卜、 lで) (r) ∪つ 〇、 ぐで) N 寸 (二〇 、く) N (▼) 卜、 寸 ⊂) ぐつ 卜、 8 ⊂) ∪つ 8 8 8 8 、〇 °5 霜 、〇 、〇 し」I _」 、、o ぐう ー しo ・、○ (▼) 、、○ ∞ 卜、 、、○ ー ー ー ー ー ー 〇、 一 l∫) 〈つZ l…寒 露 ’畿 〇 三 享 も ⊂) そヾ ≧ ふ 〔ヽ ≧ 8 亨 等 手 写 ≧ も 〔つ 亨 隷 き き\ き め で\ ≧ も り 亨 8 しu 寸 る○ し1」 ト (▼) き\ 享 も 寸 ≧ 8 早 8 寸 早 8 寸 半 合 も ≧ 衰 ≧ 8 ≧ ふ い し」) 命 も、 ししI 等 こ○ 」U ≡ 」 ○∠ < し」」 `章二) 罵 N Z 薫 “寸“ 卜、 くノう 蔓 oつ 案 等 くノウ 藷 寸 く/つ ⊂) ○ 卜、 U“) 薫 Cト ∪つ くの 、o 霊 卜、 しっ ⊂) 罵 Z § Z 隷 し。 Z (ヽつ 巻 Z o N Z 卜、 嵩 Z 嘗 CO 之 N ° 8 Z ぐヾ ° 8 Z 薫 くノつ 中 洲 ○ヽ ⊂) くつ ∪⊃ 鴛 Z 薫 寸 トー `/) ㌢ “寸- 卜、 Z 寸 o N (ノ) し」I Z ー 望 (▼〕 寸 lで) 、○ 卜ヽ (義二〇 〇、 ⊂) - N くつ 寸 」で) 、、o 卜、 ∞ 〇、 ⊂) ー N ぐつ ー●」 ー●」 _」 一一」 _」 一一」 一〇」 .○○ _」 ,●」 _,」 _」 ._」 .●.」 ○○」 一〇」 一一」 ー●」 _」 N _」 ぐヾ .●●」 ぐヾ _」 N 。。」 露 しi」 N主○ 昌 ⊂) NC GRID (NAD 83) し__ノ_ 十、ヽI・手車 Zllllllll\lし//て∴\ \l l \ ノ/.しヰくくl\〇、〇叩言 、へ、、「、、子∴∴ II II Iエコ「 細 りIII/8i王国圏ヽ 雪害 1.00 GENERAL NOTES 1.01 ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS AND SPECIFICATIONS. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE STATE, LOCAL AND NATIONAL CODES, ORDINANCES AND OR REGULATIONS APPLICABLE TO THIS PROJECT. 1.02 THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE PROJECT MANAGER AND/OR ENGINEER AND BE RESOLVED BEFORE PROCEEDING WITH WORK. WHERE THERE IS A CONFLICT BETWEEN DRAWING AND VERIZON SPECIFICATIONS, THE VERIZON PROJECT ENGINEER SHOULD BE CONTACTED FOR CLARIFICATION. 1.03 ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE PROJECT MANAGER AND/OR ENGINEER SO THAT PROPER REVISIONS MAY BE MADE. MODIFICATION OF DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF THE PROJECT MANAGER AND/OR ENGINEER. 1.04 CONTRACTOR SHALL REVIEW AND BE FAMILIAR WITH SITE CONDITIONS AS SHOWN ON THE ATTACHED SITE PLAN AND/OR SURVEY DRAWINGS. 1.05 WAVEGUIDE BRIDGE AND EQUIPMENT CABINETS ARE SHOWN FOR REFERENCE ONLY. REFER TO SEPARATE DRAWINGS FOR SPECIFIC INFORMATION. 1.06 ALL FINISHED GRADES SHALL SLOPE MINIMUM 1/4 IN./FT. AWAY FROM EQUIPMENT IN ALL DIRECTIONS. CONTRACTOR SHALL SLOPE SWALES AS REQUIRED ALONG EXISTING TERRAIN TO DRAIN AWAY FROM COMPOUND AND ACCESS DRIVE. 1.07 THE PROPOSED TOWER AND TOWER FOUNDATIONS WERE DESIGNED BY OTHERS. TOWER INFORMATION PROVIDED ON THESE PLANS ARE PROVIDED FOR REFERENCE PURPOSES ONLY. NOTIFY ENGINEER OR PROJECT MANAGER OF ANY CONFLICTS OR DISCREPANCIES. CONTRACTOR TO OBTAIN COPY OF TOWER DESIGN DRAWINGS, IF AVAILABLE, FROM VERIZON PROJECT MANAGER TO CONFIRM COAX ROUTING AND ANTENNA MOUNT INFORMATION. 1.08 THE CONTRACTOR SHALL PROVIDE ADEQUATE EXCAVATION SLOPING, SHORING, BRACING, AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL SAFETY ORDINANCES. 1.09 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY CONSTRUCTION ACTIVITIES TO THE EXISTING ACCESS ROAD AND COMPOUND GRAVEL AREAS. ANY NEW FILL MATERIALS SHALL BE COMPACTED. 1.10 THE CONTRACTOR IS HEREBY NOTIFIED THAT PRIOR TO COMMENCING CONSTRUCTION, HE IS RESPONSIBLE FOR CONTACTING THE UTILITY COMPANIES INVOLVED AND SHALL REQUEST A VERIFICATION AT THE CONSTRUCTION SITE OF THE LOCATIONS OF THEIR UNDERGROUND UTILITIES AND WHERE THEY MAY POSSIBLY CONFLICT WITH THE PLACEMENT OF IMPROVEMENTS AS SHOWN ON THESE PLANS. THE CONTRACTOR OR ANY SUBCONTRACTOR FOR THIS CONTRACT WILL BE REQUIRED TO NOTIFY "NORTH CAROLINA 811" 48 HOURS IN ADVANCE OF PERFORMING ANY WORK BY CALLING THE TOLL FREE NUMBER (800) 632-4949 (OR 811). ANY UTILITIES DAMAGED BY CONSTRUCTION ACTIVITIES SHALL BE REPAIRED BY THE CONTRACTOR, AT NO EXPENSE TO THE OWNER. 1.11 CONTRACTOR TO PROVIDE DUMPSTER AND PORTABLE TOILET FACILITY DURING CONSTRUCTION. 1.12 CONTRACTOR TO PROVIDE STYMIE LOCK OR EQUIVALENT AS APPROVED BY VERIZON PROJECT MANAGER. 1.13 CONTRACTOR TO PROVIDE ANY NECESSARY SIGNAGE PER VERIZON PROJECT MANAGER'S INSTRUCTIONS. SEE DETAIL ON SHEET C15. 2.00 EQUIPMENT FOUNDATION NOTES 2.01 FOUNDATIONS ARE DESIGNED FOR A PRESUMPTIVE ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. CONTRACTOR SHALL VERIFY SOIL CONDITIONS AND BEARING CAPACITY PRIOR TO CONSTRUCTION. 2.02 EXCAVATE A MINIMUM 18" BELOW PROPOSED EQUIPMENT FOUNDATIONS OF EXPANSIVE, ORGANIC, UNCONSOLIDATED OR OTHERWISE UNACCEPTABLE MATERIAL AND REPLACE WITH WELL -COMPACTED MATERIAL ACCEPTABLE TO VERIZON. 2.03 CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING, PROTECTING, AND RELOCATING AS REQUIRED ALL SERVICE AND UTILITY LINES IN VICINITY OF THE WORK SITE. ALL EXCAVATIONS NEAR THESE LINES TO BE CARRIED OUT WITH EXTREME CAUTION. COORDINATE ALL RELOCATIONS WITH THE PROPERTY OWNER. 2.04 CONTRACTOR TO CUT/FILL EXISTING COMPOUND SUBSOIL TO PROVIDE AN AREA AS LEVEL AS POSSIBLE FOR THE EQUIPMENT FOUNDATIONS. ALL FILL AREAS ARE TO BE FILLED WITH SUITABLE MATERIALS. FILL MATERIALS ARE TO BE PLACED, COMPACTED, AND TESTED IN MAXIMUM LAYERS OF 8". COMPACTION OF ALL FILL MATERIAL SHALL ACHIEVE 95 PERCENT OF MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D 698. ALL TESTS MUST MEET THE MINIMUM SPECIFIED SOIL BEARING CAPACITY. COMPACTION TESTING IS BY THE GEOTECHNICAL TESTING COMPANY DESIGNATED FOR THE PROJECT. SCHEDULING AND COORDINATION IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. REPORTS OF ALL TESTING ARE TO BE PROMPTLY DELIVERED OR FAXED TO THE VERIZON WIRELESS PROJECT MANAGER. 2.05 CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS AND SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST REVISION TO ACI-318 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. 2.06 CONCRETE SHALL HAVE A SLUMP BETWEEN 3" AND 6". 2.07 REINFORCING BARS SHALL CONFORM TO THE LATEST REVISION OF ASTM-A615 GRADE 60 SPECIFICATIONS AND BE DETAILED IN ACCORDANCE WITH THE LATEST REVISION TO ACI-318. 2.08 AT THE REQUEST OF THE VERIZON WIRELESS PROJECT MANAGER, TEST CYLINDERS SHALL BE MOLDED AND LABORATORY CURED IN ACCORDANCE WITH ASTM C31. THREE CYLINDERS SHALL BE TAKEN FOR EACH DAY'S CONCRETE PLACEMENT. CYLINDERS SHALL BE TESTED IN ACCORDANCE WITH THE LATEST REVISION TO ASTM C39. 2.09 CHAMFER ALL EXPOSED EXTERNAL CORNERS OF CONCRETE WITH Y'4" x 45' CHAMFER, UNLESS OTHERWISE NOTED. 2.10 CONCRETE FORMWORK IS TO BE STRIPPED WITHIN 48 HOURS. VIBRATION OF THE CONCRETE MUST ASSURE THAT HONEYCOMBING WILL BE AT A MINIMUM. MECHANICAL VIBRATION OF ALL CONCRETE IS REQUIRED UNLESS OTHERWISE DIRECTED BY VERIZON WIRELESS' PROJECT MANAGER. ABOVE GRADE CONCRETE IS TO BE RUBBED AND PATCHED TO ASSURE SMOOTH FINISH AT TIME OF FORMS REMOVAL. CONTRACTOR SHALL PROVIDE A BROOM FINISH ON THE TOP SURFACE OF THE EQUIPMENT FOUNDATION UNLESS OTHERWISE DIRECTED BY VERIZON WIRELESS' PROJECT MANAGER. 2.11 TOPS OF CONCRETE FOUNDATION MUST BE WITHIN 0.02' OF ELEVATION REQUIRED. 2.12 TOP OF FOUNDATION FINISH TO BE LEVEL ±X- IN 10'. 2.13 TOP OF FOUNDATION TO HAVE MEDIUM BROOM FINISH. 2.14 CONTRACTOR SHALL REFER TO DRAWINGS OF OTHER TRADES AND VENDOR DRAWINGS FOR EMBEDDED ITEMS AND RECESSES NOT SHOWN ON THE STRUCTURAL DRAWINGS. CONTRACTOR SHALL VERIFY PLACEMENT OF EQUIPMENT AND LOCATION OF CONDUIT FOR MANUFACTURER'S AND VENDORS SPECIFICATIONS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL OPENINGS AND SLEEVES FOR PROPER DISTRIBUTION OF ALL UTILITIES. verizonol 8821 RESEARCH DRM CHARLOTTE, NORTH CAROLIHA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 06/20/16 CONSTRUCTION ::REV.: --DATE: SSUED FOR: BY:= 0 06/20/16 CONSTRUCTION WCE CONSULTANT, Kimley>>> Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY-HORN.COM NC License F-0102 =DRAWN BY:==CHK.:-===APV.: KMP I KRM WCE 4N CARD'' 9 ' E L g i 0 1 45 Z Gj C GENERAL NOTES N1 ° 018985035 fhb doe-n% fag~ Wth tie concept. and drlg. p-t6d hwaln, o• an IrAmrnwd of -Aw, Y inf.Mwl only for the .p.dflo wpor and client for �Nah R •a. pnpand R.- of and h*.pr nI.- on fhb don nt .Itha t BMW aAMrholbn and adaptation by KImNy-Horn and A-debm kp..holl 6• wRhout W6ERy to KYNrrHom and A -lot-, kn. CaVfl t KlmlerHom and Anadnle., Inc, 201E I TOWER SETBACKS TO PROPERTY LINES (FROM TOWER CENTER NORTH 381'-1" SOUTH 1517'-4" EAST 806'-1" WEST 234'-1" ems' s � ` I ' �� LARRY R. LANEY DB 2648 PG. 330 DAVID M. CARPENTER / DB 2817 PG. 1556—�4 I --BILLY LAIL IRREVOCABLE l� I LIVING TRUST LITTLE FAMILY FARM, LLC DB 3088 PG 154E DB 2729 PG. 1797 i ! ! NEW 100' X 100' LESSEE LEASE AREA —mom (10,000± SQ. FT.)(SEE SHEET C2) `- fB 39 PG 187 2 { 3 o PID 369601257238 4 GRASSY CREEK JIMMY S. AND j / RAYNELL J. LITTLE DB 1037 PG 151 �9s TRACT 3 - LESSEE 30' WIDE NON—EXCLUSIVE ROAD d I PB 64 PG 197 ACCESS AND UTILITY RIGHTS OF LESSEE 12' WIDE ® WAY (59,387f SQ. FT.) �� GRAVEL ACCESS NEW 60' X 60' COMPOUND ® DRIVE (1955'f LONG) GEORGE H BISSETTE p W/ 3 STRANDS OF BARBED WIRE ` t R3o,.� �P (SEE SHEETS C7—C16) DB 2013 PG. 1936 ! (8' MIN HEIGHT)(SEE SHEET C6) ` TYp _ I PID 369601354455 I NEW 117' MONOPOLE TOWER ELLIOT AND LOUNETTE WITH 115' RAD CENTER ,� � '� FORBES—ROBINSON 8 DB 1617 PG 330 LOT 1 (120' TO HIGHEST APPURTENANCE) ` PB 29 PG 119 1 (SEE SHEET C19) ,� Y 7 220' TOWER FALL 1 1t �6 7 — — PID 369601257238 ®� ZONE SETBACK EXISTING POND 5\ 3 / ! ELLIOT AND LOUNETTE 4'H X 20'L X 10'W PB 29 PG 119 A\ f ! FORBES—ROBINSON ! DB 1617 PG. 330 ° BOX CULVERT % 4 2 e ! ! PB 25 PG 29 ° SEE SHEETS C14 & C15) °_� 6 ! / —_ .— AE FLOOD ZONE —� 5\ PID 369601257238 I PID 369601257238 ° ELLIOT AND LOUNETTE 6, PB 26 PG 130 FORBES—ROBINSON ELLIOT AND LOUNETTE B 4 2 1 I FORBES—ROBINSON J DB 1617 PG. 330 3 t ° ° PB 25 PG 29 ® DB 1617 PG. 330 PB 25 PG 29 1 ��PB 43 PG 146 f 2 r. P ° TRUDIE G. CRAWFORD DB 3078 PG 1699 / � APB 19 PG 286 / 4 ! PB 18 PG 365 I OVERALL SITE PLAN C SCALE: 1 ° = 500' SURVEY NOTE: 1. VERIZON WIRELESS STAFF SHALL COORDINATE WITH THE PROPERTY OWNER TO OBTAIN THE PROPER EASEMENT AGREEMENTS TO CONSTRUCT AND MAINTAIN EQUIPMENT IN AND AROUND THE TOWER COMPOUND. 2. PROPOSED COMPOUND LAYOUT BASED ON SURVEY PROVIDED BY DDE LAND SURVEYING & CONSULTING, PA DATED 01/08/16 AND SITE VISIT ON 11 /24/15. PB 23 PG 166 0 250 500 1000 GRAPHIC SCALE: 1" = 500' verizon✓ 8821 RESEARCH DRIVE CHARLOTTE, NORTH CAROLLVA 2828E ROJECT INFORMATION: VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNT`! URRENT ISSUE DATE: 06/20/16 SSUED FOR: CONSTRUCTION EV.:--DATE:SSUED FOR:- ONSULTANT: KimleyoHorn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORN.COM NC License F-0102 ONSULTANT. RAWN BY:=CHK.:APV.: KMP KRM WCE CENSER: ��•��N CA 45 Z; C. E� HEET TITLE: OVERALL SITE PLAN SHEET NUMBER: EVISION: C1 ° 018985035 1�n CONSTRUCTIONWCE ThY dooamnd, tog.&- .Mh th. —.Wt• aW dalpn p..nt.d hr.ln, u an in.trunw,l d -,vl-. I. lnt.ndW any t.r it. p ft Moo- end ahnt W .Neh It — pnpa,.d P.— d and Impnpr r $a— m thh d—.t 0&—i .dtl.n anti—hallan mW adapt. by KImMy—H.. mW A adJ bw, M..hdl b..Rhout kbft io KMry—Hom mW N.oelaW, Ir. . Capydpht IOmky—Ham and AnoeWle., ine, 7010 LESSEE 30' WIDE NON—EXCLUSIVE ACCESS AND UTILITY RIGHTS OF WAY (59,387f SQ. FT.) LESSEE 12' WIDE GRAVEL ACCESS DRIVE (1955'f LONG) �5 (SEE SHEETS C7—C13) 0 LESSEE 20' X 60' PARKING AND TURN AROUND AREA NEW 12' SWING GATE (SEE SHEET C6) NEW 60' X 60' FENCED COMPOUND W/ 3 STRANDS OF BARBED WIRE x (8' MIN. HEIGHT)(SEE SHEET C6) LESSEE 117' MONOPOLE TOWER x I I W11H 115' RAD CENTER (120' TO HIGHEST APPURTENANCE) (SEE SHEET C19)I '^ �xll NEW 100' X 100' LESSEE LEASE AREA (10,000f SQ. FT.) L- 4, NEW MUL11GANG METER RACK 4' } T 1l1' I al I x FUTURE 30' CO—LOCATORI (TYP. OF 3) L LX—X—X—X—X X—X—X—X SITE NOTES: 1. VERIZON WIRELESS STAFF SHALL COORDINATE WITH THE PROPERTY OWNER AND/OR TOWER OWNER TO OBTAIN THE PROPER EASEMENT AGREEMENTS TO CONSTRUCT AND MAINTAIN EQUIPMENT IN AND AROUND THE TOWER COMPOUND. 2.PROPOSED COMPOUND LAYOUT BASED ON SURVEY PROVIDED BY DDE LAND SURVEYING & CONSULTING, PA DATED 01/08/16 AND SITE VISIT ON 11/24/15. 3. CONTRACTOR TO CONFIRM WITH VERIZON CONSTRUCTION MANAGER THAT THE EQUIPMENT SHOWN HAS BEEN ORDERED/SCHEDULED FOR DELIVERY TO THIS SITE. 4. THE BASIS OF EQUIPMENT DESIGN INCLUDES ONE (1) COMMSCOPE RBA72-36 BATTERY CABINET, ONE (1) COMMSCOPE RBA72 RF CABINET, AND ONE (1) ERICSSON RBS 6120 RF CABINET. \5. ROUTE COAX/FIBER UP TOWER PER STRUCTURAL ANALYSIS BY TOWER OWNER. 6. TOWER DIMENSIONS SHOWN ON THIS PLAN ARE FOR TOWER CENTER LOCATION. CONTRACTOR TO OBTAIN COPY OF TOWER ERECTION \: DRAWINGS FROM VERIZON CONSTRUCTION MANAGER PRIOR TO DRILLING TOWER FOUNDATIONS. CASSIONS AND TOWER SHOWN ON THIS PLAN ARE ILLUSTRATIVE, SEE DESIGN DRAWING BY OTHERS. DO NOT SCALE. x LESSEE 11'-6" X 20' CONCRETE EQUIPMENT PAD W/ EQUIPMENT CABINETS AND GENERATOR (SEE SHEET C3) x , x 4'-9" x x �x I LESSEE 12' X 30' EQUIPMENT AREA iI (360f SQ. FT.) X x 1 —LESSEE 41'f WAVEGUIDE BRIDGE (8' MIN. CLEARANCE) (SEE SHEET C18) I j SITE PLAN C2 SCALE: 1" = 20' 0 10 20 40 GRAPHIC SCALE: 1" = 20' verizon't' 8821 RESEARCH DRIVE CHARLOTTE, NORTH CABOLIHA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY URRENT ISSUE DATE: IF— 06/20/16 CONSTRUCTION EV.:�ATE:�SSijFn FnR:—�av- 0 06/20/16 CONSTRUCTION I mley*Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY-HORN.COM NC License F-0102 -DRAWN BY:==CHK.: A '.: II KMP I KRM I WCE o :oFE oti.,2' SE 0 5 Z� SITE PLAN -SHEEP NUMBER: EVISION C2 ° 018985035 -- . . __ -- .-- _. _.- .__ - - __ _._... -- wy,__ v N,.q _ via � - . u..rtneuc .mom m Rrxy-n as N wft k I- Copyrlph! gmlry-Hom and A ..doim 1-. 2015 PROPOSED LESSEE 12' X 30' EQUIPMENT AREA (360t SQ. FT.) —Z 1'-9" WAVEGUIDE POST FOUNDATION WAVEGUIDE BRIDGE 6' TWO (2) HYBRID FIBER CABLES 3'-9" L EQUIPMENT PAD NOTES: 1. REFER TO THE SITE PLAN ON SHEET C2 FOR EQUIPMENT PAD LOCATION AND ORIENTATION. 2. RUN 4" TELCO CONDUIT OVERHEAD ON WAVEGUIDE BRIDGE USING 16" RADIUS SWEEPS AT ALL BENDS. CONNECT TO 12X12X6 PVC NEMA BOX ON SIDE OF RBA72. 3. RUN 2" POWER CONDUIT OVERHEAD ON WAVEGUIDE BRIDGE, SWEEP DOWN CABLE LADDER TO APPROX. 5' HIGH, THEN SWEEP OVER TO 6X6X6 PVC NEMA BOX ON SIDE OF RBA72. 4. RUN 2" POWER CONDUIT OVERHEAD ON WAVEGUIDE BRIDGE, SWEEP DOWN CABLE LADDER TO APPROX. 6" HEIGHT, THEN ELBOW OVER TO LB FITTING ON SIDE OF PLINTH BELOW 6120 RF CABINET. 5. RUN HYBRID CABLE OVERHEAD ON WAVEGUIDE BRIDGE, SWEEP DOWN CABLE LADDER TO APPROX. 18" HEIGHT, THEN SWEEP OVER TO PENETRATION IN DOGHOUSE ON BACK OF RBA72 RF CABINET. 6. FASTEN CONDUITS TO UNISTRUT ON WAVEGUIDE BRIDGE AND CABLE LADDER WITH TWO PIECE HOT DIP GALVANIZED CONDUIT STRAPS. 7. BOLT CABINETS AND GENERATOR TO SLAB USING FASTENERS SPECIFIED BY EQUIPMENT MANUFACTURER IN FACTORY PROVIDED MOUNTING HOLES. B. SAWCUT CONTROL JOINT TO BE TREATED WITH SIKADUR 51 SL SEALANT OR APPROVED EQUAL. 2' /RBA72 I I � RBA72-36 1'-9. TDSGA (SEE "E" SHEETS) 5'-6" EXTEND WAVEGUIDE POST TO INSTALL LIGHT LESSEE 11'-6" X 20' CONCRETE EQUIPMENT PAD W/ EQUIPMENT CABINETS AND GENERATOR SIX (6) 1%" COAX CABLES COMMSCOPE WB—CF90 ICE 1}2" DEEP SAWCUT BRIDGE CORNER FILLER I�/ 1 i i I I CONTROL JOINT 4" TELCO CONDUIT I •_8"I � RBS46120'I2" POWER CONDUIT COAX JUMPER CABLES 5'-6" 1 EQUIPMENT PAD LAYOUT C3 SCALE: 1" = 3' 1'-6" LESSEE 3'-2" X 7'-11" 30KW GENERATOR 6' 2'-6" —6 11 PAD MOUNTED CABLE TRAY (SEE "E" SHEETS) LESSEE 6' H—FRAME W/ INTEGRATED LOAD CENTER, DISCONNECT, AND TELCO BOX 0 1.5 3 6 GRAPHIC SCALE: 1" = 3' verizonv 8821 RESEARCH DRIVE CHARLOTTE, NORTH IAROMEA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 06/20/16 CONSTRUCTION 0 06/20/16 CONSTRUCTION WCE mley>>> Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORN.COM NC License F-0102 =DRAWN BY:==CHK.:APV.:— KMP I KRM I WCE =ICENSER: ,,o►►►...�... CA %=o�� ••S �•: y. • SEAL 745 Z: .� �•.�. ��'qM C . E •�'�, EQUIPMENT PAD LAYOUT C3 ° 018985035 ne —rt. ,r, toga •t", r emepn me a gm p,rrtr . r m nuvumrn m —, r I.— ony ror — •p• pm— one ment mr .n rt — I-"e wear! mw Ynper ropmg— m tt& dm—t .Maul wrMm outhorhdbn and M 10m by—Hom and Aroebe, hFa. ehdl be ed0aul eobclq to Kudy—Hem me Naoowr, bc. Cop/,W M.I y—Hom and Aeeodoh.. Inc, 201E ALL OVERHEAD CONDUITS TO BE MOUNTED TO %" P3300 UNISTRUT MOUNTED TO SIDE FLANGE OF WAVEGUIDE BRIDGE USING UNISTRUT P1498 FITTINGS. SUPPORT TELCO AND ELECTRICAL CONDUIT FROM UNISTRUT USING TWO PIECE HOT DIP GALVANIZED CONDUIT CLAMPS. LESSEE 11'-6" X 20' CONCRETE EQUIPMENT PAD W/ EQUIPMENT CABINETS AND GENERATOR #4 ® 1'-0" (MAX.) E.W. 2" CLEAR FINISH TOP AND BOTTOM TYP. U.O.N GRADE 4Y4" t7!t e,7 fit' •�' .�s' v I `..' /� \! `l ...`. ✓ \ \..t � °` .., (, �r� �\ ��`` ,� J t f f .Y '\ ... P\. � `, � �f 4 f \. \,. / � \. fif i .l• ;�{ f � `�f � \ f -1 " /CLE 6 OF #57 STONE —MIN. fr WELL COMPACTED FILL MATERIAL (18" MINIMUM) ` 18"0 WAVEGUIDE ° °, BRIDGE POST FOOTING (SEE SHEET C18) f WAVEGUIDE BRIDGE KIT (PART #: WB—K210—B15 WITH MF-273 BURIAL POST OR APPROVED EQUIVALENT) WAVEGUIDE POST (SEE SHEET C18) VALMONT/SITE PRO SITE STRUT OR APPROVED EQUAL. FASTEN TO POST USING Y2"0 GALVANIZED U—BOLT OR APPROVED EQUAL. COLD GALVANIZE ANY DRILLED HOLES IN SITE STRUT AND AT ANY CUT—OFF BOLT ENDS. EQUIPMENT PAD FOUNDATION SECTION C4 % SCALE: 1" = 2' 0 1 2 4 GRAPHIC SCALE: 1" = 2' verizonv' 8921 RESEARCH DRIVE CHARLOTTE, NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 06/20/16 CONSTRUCTION 0 06/20/16 CONSTRUCTION WCE mley* Ho 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770—B25-0744 WWW.KIMLEY—HORN.COM NC License F-0102 —DRAWN BY:==CHK.: APV.: KMP I KRM I WCE N CAR EA 417 5 Z EQUIPMENT PAD FOUNDATION SECTION DETAILS C4 ° 018985035 m% aoeam•nt, mg• .tm u. —.Wu ane augn p—w awn, a an m.wr m .r . r mft m ony far u. pwmn wpow am m t for .ram E — ""red. Ibuw of and Vnpmp.r rHan an tta. doe—nt •Mout .rltl.n a ftl aban and odoptalbn by gmYy—Ibm and Auod b k kq •hall b..M-d kbft to Kk J y—Hom and A—;aM h- Capy,W IEml.y—Hom and Aoaekda., Inc., 201E LESSEE 11'-6" X 20' CONCRETE EQUIPMENT PAD W/ EQUIPMENT CABINETS AND GENERATOR #4 ® 1'-0" (MAX.) E.W. ALL OVERHEAD CONDUITS TO BE MOUNTED TO 7/8" P3300 UNISTRUT MOUNTED TO SIDE FLANGE OF WAVEGUIDE BRIDGE USING UNISTRUT P1498 FITTINGS. SUPPORT TELCO AND ELECTRICAL CONDUIT FROM UNISTRUT USING TWO PIECE HOT DIP GALVANIZED CONDUIT CLAMPS. 2" CLEAR Z_ WAVEGUIDE BRIDGE KIT (PART #: WB-K210-B15 WITH MF-273 BURIAL POST OR APPROVED EQUIVALENT) WAVEGUIDE POST (SEE SHEET C18) SITE STRUTS TO SUPPORT DIPLEXERS. INSTALLED AS REQUIRED. VALMONT/SITE PRO SITE STRUT OR APPROVED EQUAL. FASTEN TO POST USING X"O GALVANIZED U-BOLT OR APPROVED EQUAL. COLD GALVANIZE ANY DRILLED HOLES IN SITE STRUT AND AT ANY CUT-OFF BOLT ENDS. 7 18"0 WAVEGUIDE ° BRIDGE POST FOOTING \1(SEE SHEET C18) fff � 4 NOTE: 1 EQUIPMENT PAD FOUNDATION SECTION IF DIPLEXERS ARE NOT INSTALLED UPON Crj SCALE: V = 2' 0 1 2 4 INITIAL CONSTRUCTION, THE LAYOUT ON DETAIL 1/C4 SHALL BE USED. GRAPHIC SCALE: 1" = 2' 10oDo0o0o0ao0o0e0o0o0 < �fiFfiF�— J-- J-- J- 1'-6" o-0-0-0-0-0-0-0=0-0r } I C Lam-- 4---J =� 1'-3" 0o0=0=000=00000=0=0r 2,—D" 0 o0=0a=0=0=0o0=0o0a=0 FINISH TOP AND BOTTOM (TYP. U.O.N.) GRADE 1'-4" 4y4" O f �J i • !i - 9 �P r I� . • r • I f �! .. ,,. �..� `'.�f. � .� `\ !., •. F,, \ f,.. „ ,P' - ``\. `� J` 6 ' � Pf - 'J i t J �' %` t f �I .�] . ,t� l f/ l f /CLEAR° ,f� J f //.J`' 6 OF 57 STONE -MIN. f ' / s / f r / / - / /, `. # d r a `�` P dj di" f f ,, WELL COMPACTED FILL), ILL ��'��� MATERIAL (18" MINIMUM)f;' s f f� r w verizon,l 882f RESEARCH DRIVE CHARLOTTE, NORTH CAROLINA 2826E VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 06/20/16 CONSTRUCTION =REV.:--DATE:—ISSUED FOR: -------BY:= 0 06/20/16 CONSTRUCTION WCE fANI imleyo Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY-HORN.COM NC License F-0102 =DRAWN BY:==CHK.:APV.: KMP I KRM I WCE EQUIPMENT PAD FOUNDATION SECTION DETAILS C5 ° 018985035 Thl• doeam•rd, togW- •Eh Er mnapb and drip. pn %d ha•in, m an in•frrrmr of rrAm. Is int•nd•d any far the •pwft plrper and agent far •Neh It a red. R— of and PnDa FrprOpr nlarr+ an W. daau.rd •Rhout M. aNnrtr IM uM adaptation by 10m4y-!bm uM Araehh•. kn. •hall W d4nN Pabft io KYnly-Hom uM N•oetah4 hle. CopyrlpM I00W-Ham and Aeoelole•, I=. 201E FENCE NOTES: 1. USE 3,000—PSI CONCRETE, FULLY 3 STRANDS OF 12 GA. CONSOLIDATED AROUND THE POST. GALV. BARBED WIRE WITH 4—POINT BARBS 2%" O.D. STANDARD 2. WHERE THE POST IS SET IN ROCK OR GALV. LINE POST CONCRETE, CORE A HOLE 12" DEEP AND fib" STEEL TRUSS ROD D CONTRACTOR TO PROVIDE AND TRUSS ROD 1 1" LARGER IN DIAMETER THAN THE POST. %" O.D. SET THE POST AND GROUT IN PLACE TIGHTENER AT ALL STYMIE LOCK OR 9 GA' 2"x2" STANDARD B'-0" O.C. USING NON —SHRINK GROUT. CORNERS (TYP.) APPROVED EQUIVALENT FENCE FABRIC GALV. PIPE (MAX.) 3. ALL POSTS MUST BE PLUMB AND ALIGNED 1-1 27X8 O.D. STANDARD WITH ONE ANOTHER IN BOTH HORIZONTAL a� GALV. CORNER AND AND VERTICAL PLANES. _. GATE POST 4. CORNERS AND GATEPOSTS FOR CHAIN STEEL GALV. LINK FENCES SHALL EXTEND ABOVE THE TENSION BAR TOP STRAND OF BARBED WIRE TO 1%" O.D. GALV. PROVIDE TENSIONING FOR THE BARBED PIPE FOR GAL O.D. STANDARD WIRE. MUSHROOM STOP GALV. RAIL AND � '� BRACE PIPE (TYP.) 5. PROVIDE MIDRAILS AND BRACING AT ALL o 7 GA. GALV. INDUSTRIAL CORNER POSTS WHERE THE FENCE ti TENSION WIRE CHANGES DIRECTION BY MORE THAN 30 00 HINGE — 180' RAIL END CONNECTOR DEGREES. (TYP.) TENSION / BRACE (TYP.) BAND (TYP.) 6. THE GRADE OF THE SITE AND FINISH GRADE INSTALLATION OF THE FENCE SHALL PROVIDE FOR NO MORE THAN A 1" GAP BETWEEN THE BOTTOM OF THE FENCE T - a' MATERIAL AND FINISH GRADE. COMMERCIAL 2'-0" - a :y FABRICATED 1" GAP ar b' (TYp ) 7. CONTRACTOR SHALL PROVIDE HOLD OPEN 1.90" O.D. ''" BETWEEN FENCE ®.r' DEVICES FOR ALL GATES AT THE 1,_Oa ; a GATE FRAME 10" MUSHROOM AND GRAVEL SPECIFIED OPEN POSITIONS, DRIVEN PIPE TYPE RECEIVERS ARE NOT AUTHORIZED. (TYP-) (TYR) STOP SEE NOTES 8. CONTRACTOR SHALL ALSO PROVIDE A 6'-0" 6'-0" SEE NOTES MUSHROOM TYPE RECEIVER AT THE CLOSE POSITION. 12'-0" CHAIN LINK FENCE AND GATE ELEVATION C6 NOT TO SCALE 3—WIRE 45' BARBED WIRE ARM W/ 3—STRANDS OF BARBED WIRE (TYP.) (TYP.) TOP RAIL z J>I CHAIN LINK w FENCE FABRIC INSTALL MUSHROOM CHAIN LINK STOP WITH SLOT FENCE w o LINE POST PARALLEL TO CLOSED of a zz 8'-0" O.C. MAX. FINISH GATES 6" OF #57 STONE IT OF SURFACING 00 < w X x GRADE291 TO LIMIT OF z FINISH DISTURGRADE r , BANCE) EXISTING GRADE — Ir�z,;,;s r�F -' �t� ✓`" s� s � e+r,r f,orr'+`G s�r�i,cf ..0'w�����7 MIRAFI 50OX r s � i�r «`' F�✓ ' f, ��r b ' r, (TO LIMIT OFEIfIf.. CONCRETE DISTURBANCE) s ,) J,�, COMPACT SUBGRADE AND 10" SURFACING TO PRODUCE AN UNYIELDING SURFACE 2 MUSHROOM STOP 3 SITE COMPOUND SURFACE DETAIL q SECTION @ FENCE (�6 NOT TO SCALE NOT TO SCALE NOT TO SCALE verizonit 8921 RESEARCH DRIVE CHARLOTTE, NORTH CAROLINA 28282 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 06/20/16 ISSUED FOR: CONSTRUCTION =REV.:--DATE,------ISSUEO FOR: ------RY:, 0 06/20/16 CONSTRUCTION WCE 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY-HORN.COM NC License F-0102 =DRAWN BY:=CHK.:APV.: KMP I KRM I WCE *'III I11ff/1I •`�N CRO'. A ESS •• �. i O • S 0175 Z: O • FENCE, GATE, AND COMPOUND DETAILS —SHEET NUMBER: REVISION: C6 ° 018985035 mr —raem, .9— — — —.W. — —.g- P-- — , an nramrwt m r mums ony TW M sps parpar am arm rar .hies n rras prapana. w sr ana ■npropsr nfaros an this audm.m r.Nlaat WrIUM wthOrlmtbn and adaptatian by pm Ho and Amdabbk kr, shall be wfthult fah fAy to KNJry-Ham and Nsoelatr, YK Cw,TV* gmlmtHom and Aeodstm, IK, 201E NOTE: CURRENT DESIGN ANTICIPATES APPROXIMATELY 53,136t SQ. FT. (1.22 ACRES) OF CLEARING AND GRADING FOR THE PROPOSED PROJECT. IF ADDITIONAL CLEARING IS REQUIRED BEYOND WHAT IS SHOWN IN THE PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND/OR PROJECT MANAGER. GRADING NOTES: 1. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEERS SPECIFICATIONS. FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 2. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. 3. CONTRACTOR SHALL BLEND EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 4. PORTIONS OF THE SITE NOT SPECIFICALLY MENTIONED WITHIN THE GEOTECHNICAL REPORT SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIALS MAXIMUM DRY DENSITY WITHIN 3 PERCENT OF OPTIMUM MOISTURE CONTENT. 5. FILL SHALL BE PLACED IN MAXIMUM 8 INCH LOOSE LIFTS. 6. UNDISTURBED AREAS WITHIN 30' INGRESS/EGRESS EASEMENT NOT NEEDED FOR UTILITY ROUTING TO BE LEFT UNDISTURBED. 7. GROUND WATER SHOULD BE REASONABLY EXPECTED. ANY DE —WATERING OR MOISTURE CONDITIONING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHOULD BE INCLUDED IN THE CONTRACT PRICE. 8. SEED ALL DISTURBED AREAS NOT TOPPED WITH GRAVEL PER SEEDING SCHEDULE ON DETAIL ON SHEET C13. 9. MAXIMUM CUT SLOPE = 2H:1V UNLESS OTHERWISE NOTED. 10. MAXIMUM FILL SLOPE = 3H:1V UNLESS OTHERWISE NOTED. LEGEND EXISTING CONTOURS — PROPOSED CONTOURS LOD/SILT FENCE — — LOD — —}— TPF TPF TPF EXISTING SPOT ELEVATION x XXX PROPOSED SPOT ELEVATION • XXX VA 1 \ GRADING & EROSION CONTROL PLAN SCALE: 1" = 40' 0 20 40 80 GRAPHIC SCALE: 1" = 40' verizonit B9E1 RESEARCH DR/VE CHARLOTTE, NORTH CAROMEA E9E9E VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY CURRENT ISSUE DATE: 06/20/16� CONSTRUCTION 1 0 06/20/16 CONSTRUCTION WCE mIeyo Ho 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770—B25-0744 WWW.KIMLEY—HORN.COM NC License F-0102 �UKAWN HY:==GHK.: APV.: KMP I KRM WCE �N CARO . o .•FEs•'�••�. SEAL 45 z �o GRADING & EROSION CONTROL PLAN 1 OF 6 C7 ° 018985035 Copydy,t IO.Wy--H m and Au•dulm 1—, 401E NOTE: CURRENT DESIGN ANTICIPATES APPROXIMATELY 53,136t SQ. FT. (1.22 ACRES) OF CLEARING AND GRADING FOR THE PROPOSED PROJECT. IF ADDITIONAL CLEARING IS REQUIRED BEYOND WHAT IS SHOWN IN THE PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND/OR PROJECT MANAGER. GRADING NOTES: 1. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEERS SPECIFICATIONS. FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 2. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. 3. CONTRACTOR SHALL BLEND EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 4. PORTIONS OF THE SITE NOT SPECIFICALLY MENTIONED WITHIN THE GEOTECHNICAL REPORT SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIALS MAXIMUM DRY DENSITY WITHIN 3 PERCENT OF OPTIMUM MOISTURE CONTENT. 5. FILL SHALL BE PLACED IN MAXIMUM 8 INCH LOOSE LIFTS. 6. UNDISTURBED AREAS WITHIN 30' INGRESS/EGRESS EASEMENT NOT NEEDED FOR UTILITY ROUTING TO BE LEFT UNDISTURBED. 7. GROUND WATER SHOULD BE REASONABLY EXPECTED. ANY DE —WATERING OR MOISTURE CONDITIONING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHOULD BE INCLUDED IN THE CONTRACT PRICE. 8. SEED ALL DISTURBED AREAS NOT TOPPED WITH GRAVEL PER SEEDING SCHEDULE ON DETAIL ON SHEET C13. 9. MAXIMUM CUT SLOPE = 2H:1 V UNLESS OTHERWISE NOTED. 10. MAXIMUM FILL SLOPE = 3H:1 V UNLESS OTHERWISE NOTED. LEGEND EXISTING CONTOURS — — PROPOSED CONTOURS LOD/SILT FENCE — — LOD —� TPF TPF TPF EXISTING SPOT ELEVATION x XXX PROPOSED SPOT ELEVATION • XXX GRADING & EROSION CONTROL PLAN SCALE: 1" = 40' OD NE Z" 0 20 40 80 GRAPHIC SCALE: 1" = 40' verizonit B921 M&MCN DRIVE MARLOTTE, NORTH CAROMNA 26128E VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY :CURRENT ISSUE DATE: 06/20/16� CONSTRUCTION 0 06/20/16 CONSTRUCTION WCE *Hord 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770—B25-0744 WWW.KIMLEY—HORN.COM NC License F-0102 :q)KAWN BY:=CHK.:--APV.: KMP I KRM WCE GRADING & EROSION CONTROL PLAN 2 OF 6 C8 0 018985035 ThI Aee„n . -- .en — nwinl. — — w....nIM Ardw. — — I— M -- Y 1— — — x...,,.."e. -- _— —1 — — r W _—_r — — __. m COPAM IOmbrHom and Aeodule., I=. 201E NOTE: CURRENT DESIGN ANTICIPATES APPROXIMATELY 53,136t SQ. FT. (1.22 ACRES) OF CLEARING AND GRADING FOR THE PROPOSED PROJECT. IF ADDITIONAL CLEARING IS REQUIRED BEYOND WHAT IS SHOWN IN THE PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND/OR PROJECT MANAGER. GRADING NOTES: 1. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEERS SPECIFICATIONS. FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 2. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. 3. CONTRACTOR SHALL BLEND EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 4. PORTIONS OF THE SITE NOT SPECIFICALLY MENTIONED WITHIN THE GEOTECHNICAL REPORT SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIALS MAXIMUM DRY DENSITY WITHIN 3 PERCENT OF OPTIMUM MOISTURE CONTENT. 5. FILL SHALL BE PLACED IN MAXIMUM 8 INCH LOOSE LIFTS. 6. UNDISTURBED AREAS WITHIN 30' INGRESS/EGRESS EASEMENT NOT NEEDED FOR UTILITY ROUTING TO BE LEFT UNDISTURBED. 7. GROUND WATER SHOULD BE REASONABLY EXPECTED. ANY DE —WATERING OR MOISTURE CONDITIONING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHOULD BE INCLUDED IN THE CONTRACT PRICE. B. SEED ALL DISTURBED AREAS NOT TOPPED WITH GRAVEL PER SEEDING SCHEDULE ON DETAIL ON SHEET C13. 9. MAXIMUM CUT SLOPE = 2H:1V UNLESS OTHERWISE NOTED. 10. MAXIMUM FILL SLOPE = 3H:1V UNLESS OTHERWISE NOTED. LEGEND EXISTING CONTOURS --- ---- ---------------- --- PROPOSED CONTOURS LOD/SILT FENCE — — LOD "ILI TPF TPF TPF EXISTING SPOT ELEVATION x XXX PROPOSED SPOT ELEVATION • XXX NpR� GRADING & EROSION CONTROL PLAN SCALE: 1" = 40' 0 20 40 80 EMMMEENNI GRAPHIC SCALE: 1" = 40' verizonol 8821 RESEARCH DRIVE CHARLOTTE, !NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 2BO37 CATAWBA COUNTY :CURRENT ISSUE DATE: 06/20/16� CONSTRUCTION :REV.:--DATE:ISSUED FOR: �Y:= 0 06/20/16 CONSTRUCTION WCE mley>>> Ho 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORN.COM NC License F-0102 R)KAWN BY:==CHK.: APV.: KMP I KRM I WCE GRADING & EROSION CONTROL PLAN 3 OF 6 C9 ° 018985035 -- — — , — — — —1 - — —.19' . --Y-Wn Of IC Ntleb1Y, h- C-FAW amby—Rom -d A—ddme 1—, 2016 NOTE: CURRENT DESIGN ANTICIPATES APPROXIMATELY 53,136t SQ. FT. (1.22 ACRES) OF CLEARING AND GRADING FOR THE PROPOSED PROJECT. IF ADDITIONAL CLEARING IS REQUIRED BEYOND WHAT IS SHOWN IN THE PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND/OR PROJECT MANAGER. GRADING NOTES: 1. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEERS SPECIFICATIONS. FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 2. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. 3. CONTRACTOR SHALL BLEND EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 4. PORTIONS OF THE SITE NOT SPECIFICALLY MENTIONED WITHIN THE GEOTECHNICAL REPORT SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIALS MAXIMUM DRY DENSITY WITHIN 3 PERCENT OF OPTIMUM MOISTURE CONTENT. 5. FILL SHALL BE PLACED IN MAXIMUM 8 INCH LOOSE LIFTS. 6. UNDISTURBED AREAS WITHIN 30' INGRESS/EGRESS EASEMENT NOT NEEDED FOR UTILITY ROUTING TO BE LEFT UNDISTURBED. 7. GROUND WATER SHOULD BE REASONABLY EXPECTED. ANY DE —WATERING OR MOISTURE CONDITIONING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHOULD BE INCLUDED IN THE CONTRACT PRICE. 8. SEED ALL DISTURBED AREAS NOT TOPPED WITH GRAVEL PER SEEDING SCHEDULE ON DETAIL ON SHEET C13. 9. MAXIMUM CUT SLOPE = 2H:1V UNLESS OTHERWISE NOTED. 10. MAXIMUM FILL SLOPE = 3H:1V UNLESS OTHERWISE NOTED. LEGEND EXISTING CONTOURS --- PROPOSED CONTOURS LOD/SILT FENCE — — LOD 74hl TPF TPP TPF EXISTING SPOT ELEVATION x XXX PROPOSED SPOT ELEVATION 0 XXX GRADING & EROSION CONTROL PLAN SCALE: V = 40' 0 20 40 80 GRAPHIC SCALE: 1" = 40' verizon,l 8821 MSWCH DRIVE CHMU0778, HORTH am0l A 2826E VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY :CURRENT ISSUE DATE: 06/20/16� CONSTRUCTION :REV.:--DATE:SSUED FOR: 0 06/20/16 CONSTRUCTION WCE mley* Ho 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-1525-0744 WWW.KIMLEY—HORN.COM NC License F-0102 -DRAWN BY:==CHK.: APV.: KMP I KRM I WCE �a���un►►�♦ �N CARO'�'�. .oFES' 'ti••2 • AL = ' 0 745 Z 0 . E GRADING & EROSION CONTROL PLAN 4 OF 6 cl o 0 018985035 -. - r-.- ._�.— -. _" ____._... _...�. _...._� .......,.�.,...,.., ......,,y,,,�.,,� .� ti„�.�-,,... my .�.w�, m xn, o• nuan .mn9' m Rmry-nem as ti.ocptr, be. C.py,W 10.k j-+I•m and A—Wt ., Ina, 201E NOTE: CURRENT DESIGN ANTICIPATES APPROXIMATELY 53,136t SQ. FT. (1.22 ACRES) OF CLEARING AND GRADING FOR THE PROPOSED PROJECT. IF ADDITIONAL CLEARING IS REQUIRED BEYOND WHAT IS SHOWN IN THE PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND/OR PROJECT MANAGER. GRADING NOTES: 1. THE CONTRACTOR SHALL CLEAR AND GRUB THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEERS SPECIFICATIONS. FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 2. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. 3. CONTRACTOR SHALL BLEND EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 4. PORTIONS OF THE SITE NOT SPECIFICALLY MENTIONED WITHIN THE GEOTECHNICAL REPORT SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIALS MAXIMUM DRY DENSITY WITHIN 3 PERCENT OF OPTIMUM MOISTURE CONTENT. 5. FILL SHALL BE PLACED IN MAXIMUM 8 INCH LOOSE LIFTS. 6. UNDISTURBED AREAS WITHIN 30' INGRESS/EGRESS EASEMENT NOT NEEDED FOR UTILITY ROUTING TO BE LEFT UNDISTURBED. 7. GROUND WATER SHOULD BE REASONABLY EXPECTED. ANY DE —WATERING OR MOISTURE CONDITIONING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHOULD BE INCLUDED IN THE CONTRACT PRICE. 8. SEED ALL DISTURBED AREAS NOT TOPPED WITH GRAVEL PER SEEDING SCHEDULE ON DETAIL ON SHEET C13. 9. MAXIMUM CUT SLOPE = 2H:1V UNLESS OTHERWISE NOTED. 10. MAXIMUM FILL SLOPE = 3H:1V UNLESS OTHERWISE NOTED. LEGEND EXISTING CONTOURS PROPOSED CONTOURS LOD/SILT FENCE — — LOD TPF TPF TPF EXISTING SPOT ELEVATION x XXX PROPOSED SPOT ELEVATION • XXX GRADING & EROSION CONTROL PLAN SCALE: V = 40' 0 20 40 80 GRAPHIC SCALE: 1" = 40' verizon,l 11112f RESEARCH DRIVE CHARLOTTE, NORTH CAROMNA 21126E VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNT( CURRENT ISSUE DATE: 06/20/16 CONSTRUCTION :REV.:--DATE:SSUED FOR: -BY:= 0 06/20/16 CONSTRUCTION WCE >»Hornl 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE 770—B25-0744 WWW.KIMLEY—HORN.COM NC License F-0102 BRAWN BY:==CHK.:====APV.: KMP KRM WCE ::I_ICFNSFR. ,,��CARO ttltt111 L 0 45 Z: GRADING & EROSION CONTROL PLAN 5OF6 C11 ° 018985035 . — .—._ _. _...—. — _ — _— -.--._ __ _._ — ._ _.—... __ r-w _ __ _. "r r— ,• — -w — — -- •ww,®,on ono aoopmuon ry q ono Auu WtIO, M •not be NElnut kdAla to KYNry—Horn WA A—clofr, hw CoPYIW M.WY—bm "nd Amdd.., 1—, 201E NOTE: CURRENT DESIGN ANTICIPATES APPROXIMATELY 53,136t SQ. FT. (1.22 ACRES) OF CLEARING AND GRADING FOR THE PROPOSED PROJECT. IF ADDITIONAL CLEARING IS REQUIRED BEYOND WHAT IS SHOWN IN THE PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND/OR PROJECT MANAGER. GRADING NOTES: 1. THE CONTRACTOR SHALL CLEAR AND GRUB' THE SITE AND PLACE, COMPACT, AND MOISTURE CONDITION ALL FILL PER THE PROJECT GEOTECHNICAL ENGINEERS SPECIFICATIONS. FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. 2. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. 3. CONTRACTOR SHALL BLEND EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 4. PORTIONS OF THE SITE NOT SPECIFICALLY MENTIONED WITHIN THE GEOTECHNICAL REPORT SHALL BE COMPACTED TO 95 PERCENT OF THE MATERIALS MAXIMUM DRY DENSITY WITHIN 3 PERCENT OF OPTIMUM MOISTURE CONTENT. 5. FILL SHALL BE PLACED IN MAXIMUM 8 INCH LOOSE LIFTS. 6. UNDISTURBED AREAS WITHIN 30' INGRESS/EGRESS EASEMENT NOT NEEDED FOR UTILITY ROUTING TO BE LEFT UNDISTURBED. 7. GROUND WATER SHOULD BE REASONABLY EXPECTED. ANY DE -WATERING OR MOISTURE CONDITIONING IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHOULD BE INCLUDED IN THE CONTRACT PRICE. 8. SEED ALL DISTURBED AREAS NOT TOPPED WITH GRAVEL PER SEEDING SCHEDULE ON DETAIL ON SHEET C13. 9. MAXIMUM CUT SLOPE = 2H:1V UNLESS OTHERWISE NOTED. 10. MAXIMUM FILL SLOPE = 3H:1V UNLESS OTHERWISE NOTED. LEGEND EXISTING CONTOURS PROPOSED CONTOURS LOD/SILT FENCE — — LOD HI TPF TPF TPF EXISTING SPOT ELEVATION x XXX PROPOSED SPOT ELEVATION • XXX GRADING & EROSION CONTROL PLAN SCALE: 1" = 40' 0 20 40 80 GRAPHIC SCALE: 1" = 40' verizonit 882f RESEARCH DRIVE CHARLo7TE, NORTH CAROLINd 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY 'CURRENT ISSUE DATE: 06/20/16 CONSTRUCTION 0 06/20/16 1 CONSTRUCTION WCE imleyo Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORN.COM NC License F-0102 BRAWN BY:=CHK.:„PV: KMP I KRM WCE CARO .� •OF Es••p�•%i SEAL • 0417 Z= . ; 9 Co GRADING & EROSION CONTROL PLAN 6 OF 6 C12 ° 018985035 CaWegld pmt•-Fbm and Assodule•, Inn, 201E EROSION CONTROL NOTES: 1. EROSION CONTROLS SHALL BE INSTALLED PRIOR TO CONSTRUCTION AND SHALL BE ADEQUATE TO MAINTAIN SEDIMENT ON SITE. 2. ALL EXCAVATED SOILS NOT NEEDED ON SITE FOR BACKFILL OPERATIONS SHALL BECOME PROPERTY OF THE CONTRACTOR AND SHALL BE TAKEN OFF SITE AND LEGALLY DISPOSED OF. 3. SOIL REMAINING ON SITE SHALL HAVE SILT FENCE TIGHTLY PLACED AROUND THE ENTIRE CIRCUMFERENCE OF THE PILE. 4. PROVIDE EROSION CONTROLS AS NECESSARY TO PREVENT EXISTING SOILS FROM DRAINING OFF SITE OR INTO EXISTING DRAINAGE STRUCTURES. 5. ERECTION OF EROSION CONTROLS SHALL BE IN ACCORDANCE WITH STATE AND LOCAL EROSION CONTROL REGULATIONS. HEIGHT: MAX. 3' MIN. 2' SECTION STEEL POSTS MAX. 8' O.C. WIRE FENCE ("HOG WIRE") FILTER FABRIC BOTTOM OF WIRE FENCE AND FILTER FABRIC BURIED 6" IN EXCAVATED TRENCH STEEL POST DRIVEN 18" INTO GROUND 1 SEDIMENT FENCE (SILT FENCE) C 13 NOT TO SCALE SEEDING SCHEDULE FOR WINTER / SPRING CONSTRUCTION ACTIVITIES SEEDING MIXTURE Species Rye (grain) Annual lespedeza (Kobe in Piedmont and Coastal Plain, Korean in Mountains) SEEDING SCHEDULE FOR SUMMER CONSTRUCTION ACTIVITIES SEEDING MIXTURE Rate (Ib/acre) Species Rate (Ib/acre) 120 Common Bermudagrass 40-80 (1-2 Ib/1,000 sq. ft.) 50 Omit annual lespedeza when duration of temporary cover is not to extend beyond June. SEEDING DATES Mountains-- Above 2500 ft: Feb 15 — May 15 Below 2500 ft.: feb. 1 — May 1 Piedmont --Jan. 1 — May 1 Coastal Plain --Dec. 1 — Apr. 15 SOIL AMENDMENTS Follow recommendations of soil tests or apply 2,000 lb/acre ground agricultural limestone and 750 lb/acre 10-10-10 fertilizer. MULCH Apply 4,000 lb/acre straw. Anchor straw by tacking with asphalt, netting, or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool. MAINTENANCE Refertilize if growth is not fully adequate. Reseed, refertilize and mulch immediately following erosion or other damage. WEATHERPROOF SIGN (AS SHOWN ABOVE): SEE NOTES BELOW FOR CONSTRUCTION AND SPACING DATA. SEEDING DATES Coastal Plain --Apr. 1 — July Piedmont --Apr. 15 — June 30 SOIL AMENDMENTS Apply lime and fertilizer according to soil tests, or apply 3,000 lb/acre ground agricultural limestone and 500 lb/acre 10-10-10 fertilizer. MULCH Use jute, excelsior matting, or other effective channel lining material to cover the bottom of channels and ditches. The lining should extend above the highest calculated depth of flow. On channel side slopes above this height, and in drainages not requiring temporary lining, apply 4,000 lb/acre grain straw and anchor straw by stapling netting over the top. MAINTENANCE A minimum of 3 weeks is required for establishment. Inspect and repair mulch frequently. Refertilize the following Apr. with 50 lb/acre nitrogen. POST MAY BE EITHER 4" DIAMETER PINE, 2" DIAMETER OAK, OR 1.33 Ib/LF ORANGE, UV RESISTANT, HIGH —TENSILE STRENGTH, POLY BARRICADE FABRIC TREE PROTECTION AREA DO NOT ENTER ZONA DE PROTECCION PARA ARBOLES — NO ENTRAR z M 6 :. •SUBGRADE NOTES INSTALL TREE PROTECTION FENCE AND SIGNAGE PRIOR TO CALLING FOR SITE INSPECTION. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. ADDITIONAL SIGNS MAY BE REQUIRED BASED ON ACTUAL FIELD CONDITIONS. 2 TREE PROTECTION FENCE C 13 NOT TO SCALE verizon,' 8821 RESEARCH DRNVE CHARLOTTE, NORTH CAROLTNA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY :CURRENT ISSUE DATE: 06/20/16 CONSTRUCTION REV.:_DATE:====1SSIIFn FnR•-av_ 0 06/20/16 1 CONSTRUCTION WCE Hord 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 77D—B25-0744 WWW.KIMLEY—HORN.COM NC License F-0102 BRAWN BY:=CHK.: APV.: KMP I KRM I WCE ♦����N CARp "% .. ♦ O -S••D�••2. SE • 04 5 Z: All's t��4 GRADING & EROSION CONTROL DETAILS C13 ° 018985035 C-WeW 10.ky—Hom a d Adotm Ina, 201E CULVERT CONSTRUCTION PHASING NOTES: 1. CONSTRUCT PROPOSED ROAD UP TO THE EXISTING STREAM. 2. CREATE TEMPORARY STREAM DIVERSION TO THE WEST OF THE EXISTING STREAM. 3. INSTALL BOX CULVERT IN THE EXISTING STREAM BED. UTILIZE THE NORTHERN SIDE OF THE PROPOSED CULVERT FOR ACCESS TO COMPACT BACKFILL OF CULVERT ON THE WESTERN SIDE. ONCE BACKFILL IS COMPLETED, RESTORE STREAM BED TO ITS ORIGINAL CONDITION. 4. ONCE THE BOX CULVERT IS IN PLACE WITH PROPER BEDDING, COVER, AND BACKFILL, REMOVE THE TEMPORARY DIVERSION TO ALLOW WATER TO FLOW THROUGH EXISTING CHANNEL AND BOX CULVERT. BOX CULVERT BEDDING NOTES: 1. EXCAVATE ALL UNSUITABLE MATERIAL UP TO 3 FEET DEEP IN THE BOX CULVERT FOOTPRINT. DEWATER THE TRENCH AS NECESSARY. REPLACE ALL UNSUITABLE MATERIAL WITH GAB COMPACTED TO 85% STANDARD PROCTOR. 2. INSTALL 8" SUB -BASE OF MEDIUM AGGREGATE COMPACTED TO 98% OF STANDARD PROCTOR. INSTALL 2" FINE GRANULAR LEVELING COURSE COMPACTED TO 98% STANDARD PROCTOR ON TOP OF 8" SUB -BASE. 3. INSTALL BOX CULVERTS PER THE NCDOT DETAILS. BACKFILL SHALL BE CLASS I-B COMPACTED TO 85% STANDARD PROCTOR. BOX CULVERT DESIGN NOTES: 1. FOR GENERAL NOTES ON BOX CULVERT DESIGN AND CONSTRUCTION SEE THE NCDOT DETAILS ON SHEET C15. 2. FOR REINFORCING AREA REQUIRED AND SPACING OF REINFORCEMENT REFERENCE ASTM C1577-15 USING A DESIGN EARTH COVER OF 0G2 FEET. 3. DESIGN LOADING SHALL BE THE MOST SEVERE OF EITHER AN AASHTO HL-93 TRUCK LOADING OR H-25 TRUCK LOADING. 4. CONTRACTOR SHALL SUBMIT STRUCTURAL CALCULATIONS AND SHOP DRAWINGS FOR REVIEW BY THE ENGINEER PRIOR TO FABRICATING THE CULVERT. LEGEND EXISTING CONTOURS PROPOSED CONTOURS LOD/SILT FENCE — — LOD TPF TPF TPF EXISTING SPOT ELEVATION x XXX PROPOSED SPOT ELEVATION • XXX TIE-IN TEMPORARY DIVERSION INTO EXISTING GRADE ,,,, y4 ENERGY DISSIPATION CLASS I RIP RAP TEMPORARY STREAM DIVERSION 0.67% RUNNING SLOPE WITH EROSION CONTROL MATTING AND 12" OF __,/ NCDOT CLASS 1 RIPRAP (SEE NCDOT STANDARD DRAWING 1630.05 AND SHEET C20) INV. 772.4 v TEMPORARY IMPERVIOUS DIKE 4'H X 10'W BOX CULVERT (SEE NCDOT STANDARD `STD. NO. CB11) BOTTOM OF CULVERT,- INV. 772.9 TOP OF CREEK BED f INV. 773.9 4v�- 1 0 1) -TEMPORARY IMPERVIOUS DIKE BEGIN TEMPORARY STREAM DIVERSION 1 BOX CULVERT PLAN �14 SCALE: 1" = 20' 0 10 20 40 GRAPHIC SCALE: 1" = 20' verizonvl 89Ef RESEARCH DRNR CHARLOM, NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 07/21 / 16� CONSTRUCTION =REV.:--DATE:-ISSUED FOR: 0 06/20/16 1 CONSTRUCTION WCE 1 07/21/16 CONSTRUCTION WCE mley>>> Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORN.COM NC License F-0102 KMP I KRM I WCE CAR �''• ��• o ..S/o 10 :--5; 0 4 Z: C). 1. .y BOX CULVERT PLAN C14 1 018985035 .. ——...___..�.. _. __..__. _ ..._..� _..., ._ __ .,.�.._ ter--- _._ _._..._ _........ _,_ ,...,...�_... ........, ..�,., .,R.,..,,� ,..,,�.,..,,, ,,.. 000.,�m .anou� .na•n wowraauon ana 000pmaon oy mmw—" m Pwoaaor, n 001 o. Without NabYRy to KkrJay—H m uW M. kftk Yee. CoprW Klmby— Iom and A mdfftm Ins, 201E NOTES: 1. 3"0 WEEP HOLES INDICATED TO BE IN ACCORDANCE WITH NCDOT SPECIFICATIONS. 2. CONCRETE IN CULVERTS TO BE POURED IN THE FOLLOWING ORDER: 2.1. WING FOOTINGS AND FLOOR SLAB INCLUDING 4" OF ALL VERTICAL WALLS. 2.2. THE REMAINING PORTIONS OF THE WALL AND WINGS FULL HEIGHT FOLLOWED BY ROOF SLAB AND HEADWALLS. 3. THE CULVERT DESIGN ENGINEER SHALL CHECK THE LENGTH OF CULVERT BEFORE STAKING IT OUT TO MAKE CERTAIN THAT IT WILL PROPERLY TAKE CARE OF THE FILL. 4. THIS BARREL STANDARD TO BE USED ONLY ON CULVERT ON 90' SKEW AND TO BE USED WITH STANDARD WING SHEET WITH THE SAME SKEW AND VERTICAL CLEARANCE. 5. DIMENSIONS FOR WING LAYOUT AS WELL AS ADDITIONAL REINFORCING STEEL EMBEDDED IN BARREL ARE SHOWN ON WING SHEET. 6. TRANSVERSE CONSTRUCTION JOINTS SHALL BE USED IN THE BARREL, SPACED TO LIMIT THE POURS TO A MAXIMUM OF 70 FT. LOCATION OF JOINTS SHALL BE SUBJECT TO APPROVAL OF THE ENGINEER. 7. STEEL IN THE BOTTOM SLAB MAY BE SPLICED AT THE PERMITTED CONSTRUCTION JOINT AT THE CONTRACTOR'S OPTION. EXTRA WEIGHT OF STEEL DUE TO THE SPLICES SHALL BE PAID FOR BY THE CONTRACTOR. 8. AT THE CONTRACTOR'S OPTION, HE MAY SPLICE VERTICAL REINFORCING STEEL IN THE INTERIOR FACE OF EXTERIOR WALL AND BOTH FACES OF INTERIOR WALLS ABOVE LOWER WALL CONSTRUCTION JOINT. THE SPLICE LENGTH SHALL BE AS PROVIDED AND PAID FOR BY THE CONTRACTOR. 9. AT THE CONTRACTOR'S OPTION HE MAY SUBMIT, TO THE ENGINEER FOR APPROVAL, DESIGN AND DETAIL DRAWINGS FOR A PRECAST REINFORCED CONCRETE BOX CULVERT IN LIEU OF THE CAST —IN —PLACE CULVERT SHOWN ON THE PLANS. THE DESIGN SHALL PROVIDE THE SAME SIZE AND NUMBER OF BARRELS AS USED IN THE CAST —IN —PLACE DESIGN. FOR OPTIONAL PRECAST REINFORCED CONCRETE BOX CULVERT, SEE SPECIAL PROVISIONS. ROADWAY WIDTH 3' ROADWAY FILL SLOPE :1 i r~- Ileli ROADWAY FILL SLOPE :1 6'BEVEL WING SLOPE WING SLOPE UPSTREAM FOR 2:1 FILL 2 •4 GI Q 9'CTS. \ FOR 2:1 FILL ONLY CONST. JT. + •4 B2 BARS- FILL FACE GRADE I '4 Bl BARS- STREAM FAC Q 2 ELEV. o — — — — — — — — — — — — — — ° CONS T. J_ _ o o I 0 3"0 WEEP HOLES Q 10'- 0't CTS. I CULVERT SECTION NORMAL TO ROADWAY END ELEVATION LENGTH OF CULVERT= Al BARS Q CTS. CORNER BARS A2 BARS Q CTS.- CORNER BARS ISEE BARREL SECTIONI ISEE BARREL SECTIONI \ - �— — r— _ — — — — — — — — — WING FOOTING JFACEI DULVERTSTA. FLOOR SLAB 2'4G1 Q 9WALL 9' HEADWALLPROJECT NO. +COUNTY STATION: CONST. IT.SHEET 2 OF 2 DEPARTMEJ' OF TRANSPORTATION A100 BARS Q CTS.- BOTTOM Of g00F SLAB _FLODR SLAB BARREL STANDARD WING FOOTIN SINGLE FT. X FT. PART PLAN ROOF SLAB PART PLAN FLOOR SLAB DETAIL CONCRETE BOX CULVERT SKEW CONNECTION OF WING FOOTING 90° 197l2 8a AXSEM3LEBY, DA7E� SPECIAL AND FLOOR SLAB WHEN SLAB BEvismxs v ETNcBT.OA _¢¢,,=,T, n•WIIHT DaE�A�D-.�aa� STANDARD IS THICKER THAN FOOTING 9CHECKED BT , AA.BRSETTE DALE , AUG. igeg '�s�K'[,zSTD. NO. CBII BI BARS Q CTS.STRE•4 B2 BARS Q CTS.F A200 BARS Q CTS: TOP OF FLODR SLAB NICDOT BOX CULVERT DETAILS C15 NOT TO SCALE verizon,l 8821 RESEARCH DRIVE CHARLOTTE, NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 26037 CATAWBA COUNTY :CURRENT ISSUE DATE: 06/20/16 CONSTRUCTION FOR: 0 06/20/76 CONSTRUCTION WCE mley>>> Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY-HORN.COM NC License F-0702 '.. --17W1WN 13Y:==CHK.:AP1/.: KMP KRM WCE BOX CULVERT DETAILS C15 ° 018985035 y ,n.Y-,nm m A.mau6 n u l o..nnart �aenq m KWr"Y-H m uw A � kftr, Irr- CDp7A�d KlmlvrHan and AtWDdalm Ins, 201E EXISTING ROADWAY 50' MIN., BUT SUFFICIENT TO KEEP SEDIMENT ON SITE 2"-3" STONE TO BE USED 12' OR WIDTH OF (SURGE STONE OR RAILROAD PROPOSED STREET, BALLAST) WHICHEVER IS GREATER. PLAN NOTES: 1. PUT SILT FENCE OR TREE PROTECTION FENCE UP TO ENSURE CONSTRUCTION ENTRANCE IS USED. 2. IF CONSTRUCTION ON THE SITES ARE SUCH THAT THE MUD IS NOT REMOVED BY THE VEHICLE TRAVEL—ING OVER THE STONE, THEN THE TIRES OF THE VEHICLES MUST BE WASHED BEFORE ENTERING THE PUBLIC ROAD. 3. IF A PROJECT CONTINUES TO PULL MUD AND DEBRIS ON TO THE PUBLIC ROAD, THE GOVERNING AUTHORITY WILL CLEAN THE AREA AND INVOICE THE FINANCIALLY RESPONSIBLE PERSON AS INDICATED ON THE FINANCIAL RESPONSIBILITY FORM. EXISTING ROADWAY NEW CONSTRUCTION 35' MIN. 15' MIN. 6" MIN. a 12" MIN. d . e.�w , , _,.�rn11-7 r"i } I`�•ir�� ilrii ABRIC UNDER STONEI�ull CROSS SECTION 1 CONSTRUCTION ENTRANCE C 16 NOT TO SCALE 6" BASE OF SURGE STONE OR RAILROAD BALLAST (2" TO 4"0 STONE TYP.) (SEE NOTE BELOW) 4" OF CRUSHER RUN/ABC STONE. CROWN 2% TO DRAIN GEOTEXTILE FABRIC MIRAFI 50OX OR APPROVED EQUAL COMPACTED SUBGRADE (95% MAX. DRY J DENSITY IN ACCORDANCE WITH ASTM D698) 12' NOTE: IF DETERMINED NECESSARY DURING GRADING AND CONSTRUCTION OF THE ACCESS ROAD BY THE VERIZON WIRELESS PROJECT MANAGER, THE CONTRACTOR SHALL INSTALL 6" BASE OF SURGE STONE OR RAILROAD BALLAST (2" TO 4"0 STONE TYP.) 2 STANDARD ACCESS ROAD DETAIL C 16 NOT TO SCALE verizonv B9E1 RESEARCH DRIVE CHARLOTTE, NORTH CAROLINA EBEBE ROJECT INFORMATION: VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY URRENT ISSUE DATE, 06/20/16 SSUED FOR: — CONSTRUCTION EV.:_DATE—====ISSUED FOR: —BY: ONSULTANT Kimley* Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 77G-825-0744 WWW.KIMLEY—HORN.COM NC License F-0102 ONSULTANT.= RAWN BY:CHK.:APV.: KMP KRM� WCE CENSER: 2 Quo ti9<••� . s = 74 z: OIN :,•y,�,/ C • • Mop,.` HEET TITLE ACCESS ROAD DETAILS SHEET NUMBER:= REVISION- C16 ° 018985035 CONSTRUCTION WCE ...... -'-'--- Copyitpld pmk,,o-Hom antl Aoodatm, Inc, 2016 I TOP BTM GATE COMPOUND FENCE MONOPOLE TOWER NO RESPASSIN VIOLATORS WILL BE PROSECUTED Q1 NO -TRESPASSING SIGN 18" HIGH X 24' WIDE (OPERATIONS PROVIDED) �t WARNING I H • Bgond this poly Remo fNuency Wds al thls site may mceed rules for human mrpusme. R.yapeddy,abydp W.0. ad is. Fww. Fe..Mv In rtdo tmpwry stet. nm�.nrw.im�m. mee.m,�rm,m�.,•.,r..a asuenp WHITE BACKGROUND w/ IN CASE OF EMERGENC RED LETTERING CONTACT: 800-852-2671 SITE: RED BACKGROUND w/ BLACK LETTERING RED BACKGROUND w/ BLACK LETTERING WHITE BACKGROUND w/ BLACK LETTERING BACKGROUNDWI LETTERING WHITE BACKGROUNDw/ RED LETTERING WHITE BACKGROUNDw/ BLACK LETTERING 2Q VERIZON WIRELESS -SITE ID SIGN 18" HIGH X 24" WIDE (OPERATIONS PROVIDED) I z�t CAUTION -1 Beyotq this point Radio hwBngTlelds at this site mq weed FCC rules for human eximum. may- bty, by dp 1W*. end da e W rile kr xaN® F raft hq-q nMmnw� n�rnmew mov.+u4.ILm+.iinrmnmlq.ry nY.h.nasumyl YELLOW BACKGROUND w/ BLACK LETTERING YELLOW BACKGROUND w/ BLACK LETTERING WHITE BACKGROUND w/ BLACK LETTERING ® NOTICE m Alpereae�Nwdd here awm(E•A9 e.awshetrJiq. M perand e0akq eb eb mat he ealwhed. ® Onyap.-Mov. Aen��a�e�a.e ® mama,weacndlhn.wsemmemleepprq.Ms ® Neinmminimansierdesamswnmasa.es ® mmw,pnbanga�eea lie w®rw fK naawe.rme.aH�a a®r e� ® N• opadabawduaeWNW Wd"dudng namlopatfix ® DoWWo beb-WO. e. MegwpreAmmu 3NOTICE-RFE SIGN 12" WIDE X 18" HIGH (OPERATIONS PROVIDED) NOTICE --� 00) • NOTICE DID FREQUENCY ENVIRONMENT AREA AMgit2H)PBISO EL ONLY BEYM THIS PONn GREEN BACKGROUND w/ WHITE LETTERING WHITE BACKGROUND w/ BLACK LETTERING WHITE BACKGROUND w/ BLACK LETTERING ®WARNING-RF SIGN (RED) Q CAUTION-RF SIGN (YELLOW) ©NOTICE-RF SIGN (BLUE) 12" WIDE X 18" HIGH 12" WIDE X 18" HIGH 12" WIDE X 18" HIGH NOTE: SEE TYPICAL SIGNS AND SPECIFICATIONS DETAIL ON THIS SHEET FOR SIGN DESIGNATIONS. FCC TOWER �/R�E��G��I//S�TR//�A�//TION N0. XXXXX)(/� WHITE W/BLACK LETTERING Q FCC REGISTRATION SIGN OVERALL SIGN 20 WIDE X 4" HIGH PLACEMENT PLAN VIEW 2 TYPICAL SIGNS AND SPECIFICATIONS C 17 NOT TO SCALE C 17 NOT TO SCALE GE 3 SITE SIGNAGE FRONT GATE VIEW C � 7 NOT TO SCALE ORANGE BACKGROUND w/ BLACK LETTERING SIGNAGE NOTES: 1. SIGNS SHALL BE FABRICATED FROM CORROSION RESISTANT PRESSED METAL, AND PAINTED WITH LONG LASTING UV RESISTANT COATINGS. 2. SIGNS (EXCEPT WHERE NOTED OTHERWISE) SHALL BE MOUNTED TO THE TOWER, GATE, AND FENCE USING A MINIMUM OF 9 GAUGE ALUMINUM WIRE, HOG RINGS (AS UTILIZED IN FENCE INSTALLATIONS) OR BRACKETS WHERE NECESSARY. BRACKETS SHALL BE OF SIMILAR METAL AS THE STRUCTURE TO AVOID GALVANIC CORROSION. verizono' 8821 RESEARCH DRIVE CHARLOTTE, NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DEWER, NC 28037 CATAWBA COUNTY CURRENT ISSUE DATE: 06/20/16 CONSTRUCTION 1 0 06/20/16 CONSTRUCTION WCE imley* Ho 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WM1WI.KIMLEY—HORN.COM NC License F-0102 BRAWN BY:=CHK.:--APV.: KMP I KRM I WCE SITE SIGNAGE DETAILS C17 ° 018985035 . -._--. _._. _- -.-.r- __ .• _ , �.� .._._ , --...-__.. �.. _. �..--. - ..._.�.. - • _. -- r-. fir...- ...- -.-.. ... ....... �.. ,.1... ... �..� ..� ..i.. .�y�.,,.. �...,�.a .., u.. wc, - - — - -- — — aoopmuon q latel7-1pm via A—kft , M. 001 be without imYlly m NYNet-HDm o A N•oelaW. h1 CopflW IllmWy—Hom and AeocWW, Inc., 2016 CONTRACTOR TO INSTALL GPS ANTENNA ON THE CLOSEST POST TO THE EQUIPMENT PER MANUFACTURER'S SPECIFICATIONS. SEE DETAIL A SEE DETAIL B W Z o ZZ W :2r o W bi W -i 3X" O.D. GALVANIZED o o z o STD PIPE WITH CAP E a� �2Ebi L` CO X2" CROWN o o? GRADE J W -I ,IkkU I w I `Q 3Y2" O.D. STD W [ a 1'-6" GALVANIZED PIPE o I I.� 1O WITH CAP SUPPORT BRACKET I w GRATED WAVEGUIDE 1'-6" /BRIDGE CHANNEL [O NOTE: 1. ALL MATERIALS FURNISHED BY CONTRACTOR UNLESS OTHERWISE NOTED. VERTICAL TRAPEZE SECTION HORIZONTAL CABLE SUPPORT SECTION DETAIL A ANDREW 1 POST WAVEGUIDE BRIDGE KIT (PART #: WB-K210-B15, OR APPROVED EQUIVALENT) WAVEGUIDE BRIDGE DETAIL C 18 NOT TO SCALE C 3J¢" O.D. STD GALVANIZED PIPE—\ WITH CAP NOTE: 1. ALL MATERIALS FURNISHED BY CONTRACTOR UNLESS OTHERWISE NOTED. CONTRACTOR TO INSTALL GPS ANTENNA ON THE CLOSEST POST TO THE EQUIPMENT PER MANUFACTURER'S SPECIFICATIONS. w z J w 3Y2" O.D. GALVANIZED L` STD PIPE WITH CAP X2" CROWN —CIIPPIIRT RRArVPT GRATED WAVEGUIDE BRIDGE CHANNEL VERTICAL TRAPEZE SECTION 0 0 0 0 R 0 0 0 0 0 0 0 0 0 0 0 0 Ll HORIZONTAL CABLE SUPPORT SECTION DETAIL B ANDREW 2 POST WAVEGUIDE BRIDGE KIT (PART #: WB-K410-B15, OR APPROVED EQUIVALENT) WAVEGUIDE BRIDGE DETAIL (ALTERNATIVE DESIGN WITH 2 PIPE COLUMNS) NOT TO SCALE verizonv 8921 RESEARCH DRIVE CHARLOTTE, NORTH CAROLWA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY URRENT ISSUE DATE: 06/20/16_ SSUECOFOR 4STRUCTION EV.:=DATE �scnFn Fna•-ay. 0 06/20/16 CONSTRUCTION WCE RNI mley* Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 3DD92 PHONE: 77D-825-0744 WWW.KIMLEY—HORN.COM NC License F—D1D2 KAWN IJY:==GHK.: APV.: KMP KRM WCE CARO , 04E 5 Z •..... C. E�JJ- WAVEGUIDE BRIDGE DETAILS —SHEET NUMBER:— EVISION- C18 ° 018985035 ,� uecun"ny m9..� mm m. mwPv vq •e91� PI�II•P Ilf�n, al InRY"MII[ 4 MrvILV. Y JML O"N W 1 Jfb ellP•Y ew e t Ter •hf J, R — ,w — — M — -- -- — — — ._„ — _—__ . CopyIW IEmIWrHom and Aeoddw 1—, 201E 'o' '0. z 0 ti PROPOSED MONOPOLE �V 'v c ry NJ SECTOR 1 ANTENNA ORIENTATION PLAN C19 (NOT TO SCALE, FOR ILLUSTRATIVE PURPOSES ONLY, SEE STRUCTURAL ANALYSIS BY OTHERS TO CONFIRM ANTENNA MOUNT TYPE) ANTENNA SECTOR AZIMUTH IN DEGREES MECHANICAL DOWN TILT ANTENNA* COMF (QTY.) MAKE/MODEL LENGTF SECTOR A 60, 0' (1) ANDREW/ HBXX6516DS-A2M_PORT 1t45_02DT_1920 N/A 60, 0' (1) ANDREW/ HBXX6516DS-A2M_PORT 1t45_02DT-2110 N/A 60, 0' (2) ANDREW/ LNX-6515DS-A1M-04DT_0750 MHZ 227't 200' 0' (1) ANDREW/ HBXX6516DS-A2M-PORT 1t45_02DT_1920 N/A SECTOR B 200' 0' (1) ANDREW/ HBXX6516DS-A2M-PORT 1t45_02DT_2110 N/A 200' 0' (2) ANDREW/ LNX-6515DS-A1M_04DT_0750 MHZ 227't 310' 0' (1) ANDREW/ HBXX6516DS-A2M-PORT 1t45-02DT_1920 N/A SECTOR G 310' 0' (1) ANDREW/ HBXX6516DS-A2M-PORT 1t45-02DT 2110 N/A 310' 1 0' 1 (2) ANDREW/ LNX-6515DS-A1M_04DT-0750 MHZ 227't * CONTRACTOR ALSO TO INSTALL THREE(3) RRUS B13 W/A2 UNITS, SIX(6) RRUS32 OR RRUS12 W/A2 UNITS, TWO(2) HYBRID FIBER CABLES, AND ANY RAYCAP BOXES AS NEEDED. CONTRACTOR TO VERIFY WITH VERIZON WIRELESS PROJECT MANAGER PRIOR TO INSTALLATION. NOTE: 1. ALL INFORMATION ON THIS PAGE IS PROVIDED BY VERIZON WIRELESS AND IS SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. CONTRACTOR SHALL CONTACT THE VERIZON WIRELESS CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION FOR ALL DETAILED ANTENNA, AND COAX CABLE INFORMATION. 2. REFER TO STRUCTURAL DESIGN PROVIDED BY OTHERS FOR ANALYSIS OF PROPOSED TOWER. 3. IT IS UNDERSTOOD THAT KIMLEY-HORN MAKES NO WARRANTY, EITHER EXPRESSED OR IMPLIED, FINDINGS, DESIGNS, RECOMMENDATIONS, SPECIFICATIONS, OPINION, OR PROFESSIONAL ADVICE RELATING TO THE STRUCTURAL ADEQUACY OF THE EXISTING TOWER OR ATTACHMENT OF ANTENNAS OR OTHER APPURTENANCES. TOP OF LIGHTNING ROD / 2 \ MONOPOLE TOWER ELEVATION - NORTH VIEW (FACING SOUTH) NOTES: NOT TO SCALE 1. ALL PROPOSED ATTACHMENTS TO TOWER BASED ON TOWER DESIGN DRAWINGS BY OTHERS (SEE GENERAL NOTE 1.07, SHEET N1). 2. THE TOWER ELEVATION SHOWN IS FOR REFERENCE ONLY. 3. COAX/FIBER CABLE LENGTHS ARE APPROXIMATE. CONTRACTOR TO VERIFY CORRECT LENGTH IN FIELD AT TIME OF CONSTRUCTION. 4. PROPOSED ANTENNAS ALSO LIGHT GRAY IN COLOR. ENT verizonol 8821 RESEARCH DRIVE CHARLOTTE, NORTH CAROLMA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY :CURRENT ISSUE DATE: 06/20/16 CONSTRUCTION ��-J 0 06/20/16 1 CONSTRUCTION WCE mIeyo Ho 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORN.COM NC License F-0102 =UKAWN 6Y:=CHK.:—APV.: KMP KRM I WCE FOR ILLUSTRATIVE PURPOSES ONLY - NO SIGNATURE REQUIRED ANTENNA AND TOWER ELEVATION DETAILS C19 ° 018985035 CaW NIA IOmby—Ilan and Anodalm I=, 201E m m o� Z o �Noo H Z77 Z = pC H�1 -i=D CS oo° xZ =�> m NOTES U F--0':o= " 1" 0 Z -p M aC " F-S~Zlj O o = D EXCAVATE TEMPORARY DIVERSION WITH NON -VERTICAL SIDE SLOPES AND NOT I- o �H GREATER THAN 1.5:1 SLOPE. zF� �'0 SEED BERM CREATED BY COMPACTED SOIL AS DIRECTED. N o m ro m COMPACTED SOIL LL �2' MINIMUM m O cf) = o 1.4 FLOW rz U) O U) D D MINIMUM ouj Z -�D i o0 < m 6' TYPICAL ¢ Q U N H O x a O Zmo H �FW- d `m CROSS SECTIONAL VIEW UU a a N SHEET 1 OF 1 SHEET 1 OF 1 m s N N N 1630.05 1630.05 N > N K 11� O U d 12" NCDOT y CLASS I RIP RAP CD_ 6 o 3' O WOVEN GEOTEXTILE ® / p C FABRIC 0 0 ` ® 1 . 1.5p 1.5 m 0 y 0 _ O _ N " COMPACTED N N EARTH C 0 N .;, I 2' 0 0 SITE SPECIFIC TEMPORARY STREAM DIVERSION SECTION C2O NOT TO SCALE a ]C verizoni/ 8821 MSSdRCH DRMs' CHARLOTTE, NORTH CAROMNA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 07/21/16 CONSTRUCTION REV.:=DAM—iSSUM FOR:— Y,_ 0 07/21/16 CONSTRUCTION WCE onIey>>> Ho 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-B25-0744 WWW.KIMLEY-HORN.COM NC License F-0102 BRAWN BY:=CHK.:—„PV.: KMP I KRM I WCE ��•`' N CAR O y A = =�g; 17 5 Z� C. EID % TEMPORARY STREAM DIVERSION C20 ° 018985035 . -.--_. _._. __ _..�_ _._ --.. � .._......_ , ._..._..".�...�...� ._....... ,. �.�,.�...,. , ., ��..�...,,� �.,.�.....,�., ,,,�,. �...,.u, ,..,� r,.yu,.u. ,aw. � .ne ..p.cpr nwnw °n vw aoorrNm .main .no•n amamaoon ona M �amwy-Mom mtl N.otlab., Yn..MI M .IWut IIaeYM1y M giN•y-Fbm aM Nnclotr, Yw. O*WrW gmby-Flom and A—latm, Ine, 201E STUB UP (2) 3" NEW 12' ----- 1\ SWING GATE POWER CONDUIT, SEE ROUTING NOTE 2 NEW MULTIGANG - METER RACK X X X X X —�X Y XX �—X FNEW 60' X 60' FENCED COMPOUND x W/ 3 STRANDS OF BARBED WIRE (B' MIN. HEIGHT) x — LESSEE 11'-6" X 20' CONCRETE EQUIPMENT PAD W/ EQUIPMENT CABINETS AND GENERATOR EXTEND WAVEGUIDE BRIDGE POST TO INSTALL LIGHT LESSEE MONOPOLE TOWER UNDER 200' �— LESSEE 41't WAVEGUIDE BRIDGE (8' MIN. CLEARANCE) FUTURE F CO -LOCATOR (TYP. OF 3) I L_ -,-- -i 2" POWER CONDUIT 3/4" ALARM CONDUIT 2" POWER CONDUIT - 11 1/4" TELCO COND 2" POWER CONDUIT STUB UP 4" TELCO CONDUIT, SEE ROUTING NOTE 2 X iX /rtx EXTEND H—FRAME POST TO INSTALL LIGHT NOTES AND SPECIFICATIONS: 1. ALL ELECTRICAL WORK SHALL COMPLY WITH NEC, STATE, AND LOCAL CODES. ALL ELECTRICAL DEVICES, MATERIALS, AND SERVICE EQUIPMENT SHALL BE LABEL —LISTED BY AN APPROVED THIRD PARTY TESTING AGENCY 2. CONTRACTOR SHALL OBTAIN OWNER/TENANT SPECIFICATIONS AND REVIEW FOR ADDITIONAL DETAILS AND REQUIREMENTS THAT MAY NOT BE SHOWN IN THESE DRAWINGS. CONTRACTOR SHALL COMPLY WITH ANY ADDITIONAL OWNER/TENANT SPECIFICATIONS AND REQUIREMENTS, 3. CONTRACTOR SHALL APPLY FOR UTILITY SERVICES, BOTH ELECTRIC AND TELEPHONE, FOR THE OWNER/TENANT. THIS APPLICATION SHALL BE MADE NO LATER THAN THE NEXT BUSINESS DAY FOLLOWING THE AWARD OF THE CONTRACT. CONTRACTOR SHALL COORDINATE WITH THE ELECTRIC UTILITY FOR THE EXACT TRANSFORMER LOCATION, METERING REQUIREMENTS, AND SERVICE ROUTING. CONTRACTOR SHALL COORDINATE WITH THE TELEPHONE UTILITY FOR THE EXACT TELEPHONE REQUIREMENTS AND SERVICE ROUTING. 1 1/4" CONTROLS/ 4. PRIOR TO PURCHASING EQUIPMENT, THE CONTRACTOR SHALL CONTACT ALARMS CONDUIT THE ELECTRIC UTILITY AND OBTAIN IN WRITING THE MAXIMUM AVAILABLE FAULT CURRENT AT THE UTILITY SERVICE POINT. PROVIDE MAX AFC x 3/4" POWER CONDUIT SIGNAGE AS REQUIRED PER NEC 110.24. THE CONTRACTOR SHALL ENSURE ALL ELECTRICAL EQUIPMENT, CIRCUIT BREAKERS, DISCONNECTS, FUSES, 2" POWER CONDUIT AND PANELBOARDS HAVE A FAULT CURRENT INTERRUPTING RATING GREATER THAN THE AVAILABLE FAULT CURRENT. IN NO CASE SHALL THE FAULT CURRENT INTERRUPTING RATING BE LESS THAN 10,000 AMPS. x 5. CONTRACTOR TO PROVIDE 200 LB TEST POLYETHYLENE PULL CORDS SECURELY FASTENED AT EACH END OF POWER AND TELCO CONDUIT INCLUDING INNERDUCTS. PROVIDE CAPS ON ENDS OF UNUSED CONDUIT. x " 6. CONTRACTOR TO PROVIDE A REBAR MARKER WITH AT LEAST 2 FEET EXPOSED ABOVE GRADE AND PAINTED BRIGHT ORANGE TO INDICATE LOCATION OF CONDUIT CAPPED BELOW GRADE. 4 TELCO CONDUIT 2" FLEX CONDUIT x 1 1/4" TELCO CONDUIT 3/4" POWER CONDUIT 3/4" ALARMS CONDUIT x 1 x LESSEE 12' X 30' EQUIPMENT AREA (360t SQ. FT.) J x X X X X X x ROUTING NOTES: 1. CONTRACTOR TO PROVIDE PULL BOXES AS NEEDED TO ENSURE NO GREATER THAN 360 DEGREES OF BENDS BETWEEN PULL POINTS IN CONDUIT RUNS. 2. CONTRACTOR COORDINATE WITH LOCAL UTILITY COMPANY FOR SERVICE TO THIS POINT. 3. COORDINATE EXACT ROUTING, INSIDE OR OUTSIDE FENCE, WITH OWNER/TENANT CONSTRUCTION MANAGER. ROUTE CONDUIT WITHIN 3' OF FENCE. 4. CONDUITS SHOULD BE ROUTED OVERHEAD ON ICE BRIDGE EXCEPT GENERATOR CONDUITS RUN ON CABLE TRAY MOUNTED TO CONCRETE PAD. 7. PRIOR TO TRENCHING CONTRACTOR SHALL LOCATE ALL EXISTING UNDERGROUND UTILITIES. CONTRACTOR SHALL REPAIR AT CONTRACTOR'S EXPENSE ANY DAMAGE TO EXISTING UTILITIES. 8. CONTRACTOR TO VERIFY EXACT ROUTING OF POWER AND TELCO CONDUIT WITH LOCAL UTILITIES AND OWNER/TENANT. ENSURE ALL CONDUIT STUB —UPS ACCOMMODATE EQUIPMENT REQUIREMENTS. 9. UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC UNLESS NOTED OTHERWISE. USE SCHEDULE 80 PVC CONDUIT UNDER ROADS AND IN AREAS ABOVE GRADE THAT ARE EXPOSED AND SUBJECT TO DAMAGE. MANUFACTURED BENDS SHALL HAVE A MINIMUM RADIUS OF 24 INCHES. 10. CONDUIT RUNS SHALL HAVE A CONTINUOUS SLOPE DOWNWARD AND AWAY FROM THE EQUIPMENT TO ALLOW WATER TO FLOW AWAY FROM THE EQUIPMENT AND SHELTER. EXCAVATE TRENCHES ALONG STRAIGHT LINES PRIOR TO INSTALLING CONDUIT TO ACCOMMODATE ADJUSTING THE ELEVATION, AS NEEDED. 11. CONDUIT ENTERING EQUIPMENT SHALL BE SEALED WITH A SEALANT THAT IS IDENTIFIED FOR USE WITH THE CABLE/CONDUCTOR INSULATION SHIELDING, ETC. 12. THE OWNER SHALL FURNISH AND THE CONTRACTOR SHALL INSTALL ADDITIONAL SIGNAGE TO BE LOCATED AT THE COMPOUND FENCE. CONTRACTOR SHALL COORDINATE WITH OWNER/TENANT CONSTRUCTION MANAGER FOR PLACEMENT OF SIGNAGE. 13. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY CONSTRUCTION ACTIVITIES TO THE LANDSCAPING AREA. 14. CONTRACTOR ENSURE A MINIMUM 3' WORKING CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT PER NEC. KEY NOTES: 15, THE CONTRACTOR SHALL ADD ENGRAVED PHENOLIC LABELTO THE FRONT OF PANEL 'PP1' O AREA LIGHT LITHONIA HFR THAT READS, MAXIMUM DRAW OF ALL 250M SCWA DNA LP1. RECTIFIERS PLUS ALL ANCILLARY EQUIPMENT CONTROL VIA CONTRACTOR SHALL NOT EXCEED 30KW. IF MORE THAN PROVIDED MANUAL TIMER 30KW OF POWER IS REQUIRED, THE SWITCH (WEATHERPROOF) EXISTING 30KW GENERATOR WILL NEED TO BE UPGRADED. BASIC SERVICE ROUTING PLAN SCALE: 1" = 10' verizon' 892f RESEARCH DR►VE CHARLOTTE, NORTH CAROL►NA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY CURRENT ISSUE DATE: 07/13/16 ISSUED FOR: CONSTRUCTION REV.:=DATE: ISSUED FOR: BY-=, 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM CONSULTANT: ® Raleigh, NC Indianapolis, IN Philadelphia, PA APOGEE Pittsburgh, Virginia Beach, VA Consulting Group, PA Fort Collins, CO w .acg-pa.com (919) 858-7420 NC License # C-1848 ACG PROJECT NO.: 2016-169 DRAWN BY:==CHK,: IRV.: AMM I NAC I JKM C A Roy per. pFESS�p�.'/41 SEAL 23894 'O N • PLO; ',c, , BASIC SERVICE ROUTING PLAN E1 1 018985035 Copyright Klmla)—Hom and Msoclotm Ino., 2018 KEY NOTES: NEW 60' X 60' FENCED COMPOUND W/ 3 STRANDS OF BARBED WIRE (8' MIN. HEIGHT) NEW 12' SWING GATE ^ (.T� --G----G� I I � I I I� I �x x x x x x x �x x x Oe� �G xC31 / 1 SEE GROUNDING / GROUND ROD NOTE 16 x I TEST WELL, SEE 1 DETAIL 3/E4 x LESSEE MONOPOLE X UNDER 200' -- 17 TDSGA (SEE DETAILS 4/E4 & 1/E7) / x / ® I x F' SEE GROUNDING x I COFUTURELOCATOR I ��\ NOTE 1 x (TYP. OF 3) I LESSEE 41't WAVEGUIDE BRIDGE (8' MIN. CLEARANCE) 1 1 x � I I � x x x— -xl x x x x x x x x—�: GROUNDING PLAN E2 SCALE: 1" = 10' 1O DEDICATED GROUND ROD PLACEMENT FOR ELECTRICAL EQUIPMENT AT METER STATION SHOULD BE AS PER NEC, MUNICIPAL AND UTILITY CO. REQUIREMENTS. GROUND ROD TO BE WITHIN 24" OF FENCE POST �J (TYPICAL OF 4.) O BOND EACH FENCE POST ADJACENT TO EQUIPMENT PAD TO GROUND RING. 1 NEW MULTIGANG METER RACK ---G SEE GROUNDING NOTE 18 r EXTEND H-FRAME POST TO INSTALL LIGHT O LESSEE 11'-6" X 20' CONCRETE EQUIPMENT PAD W/ EQUIPMENT CABINETS AND GENERATOR O FOR GPS - TDSGA, (SEE GROUNDING NOTE 11 AND DETAIL 2/E7) O SEE GROUNDING NOTE 17 SEE GROUNDING NOTE 16 LESSEE 12' X 30' EQUIPMENT AREA (360t SQ. FT.) SEE GROUNDING NOTES ON E11 LEGEND: GROUND ROD EXOTHERMICALLY WELDED TO GROUND RING (SEE DETAIL 2/E4) - - -G — GROUND RING • EXOTHERMIC WELD e ��GR��O��UN��D ROD ��T��EFFS44T�� WELL S /17'�T I L/�7^1 0 MECHANICAL CONNECTION verizon,' 8921 RESEARCH DRIVE CHARLOTTE, NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 07/13/16 CONSTRUCTION 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM MIey>>> H o r 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORN.COM ® Raleigh, NC Indianapolis, IN Philadelphia, PA APOGEE Pittsburgh, PA Virginia Beach, VA Consulting Group, PA Fort Collins, CO w .acg-pa.com (919) 858-7420 NC License # C-1848 ACG PROJECT NO.: 2016-169 =DRAWN BY:=CHK.:APV.: AMM I NAC I JKM 11111111111////,/ .�`����N • C A R o of ESS/0N•'//L = e�SEAL 9l v 238 4 0 c; %,,IkEV�IN111` ly;A GROUNDING PLAN E2 1 018985035 Copyright Klmley—H— and A—cf tea, Ina, 2016 GFI RECEPTACLE 2-12 AWG, 1-12 AWG EG IN 1 /2' POWER CONDUIT 3-3/0 AWG, 6 AWG CU EG, 2" CONDUIT 2 AWG SUPPLEMENTAL GROUND 2-12 AWG, 1-12 AWG EG IN 1 /2" POWER CONDUIT GFI \ RECEPTACLE u AREA LIGHTS o 800A TWO PARALLEL RUNS, EACH 3-500 kCMIL 120/240V 1 PH IN 4" CONDUIT, BY UTILITY COMPANY 3-WIRE "B m PROPOSED MULTI -GANG METER CENTER, 800A 120/240V, 1 q,, 3-WIRE, 200A METER SOCKETS, SE RATED, UL LISTED, NEMA 3R ENCLOSURE — � H-FRAME UTILITY RACK 2/0 AWG Moog 200A) 0 o) o) o 0 N MBJ & GEC SEE SIGNAGE NOTE 93). _ 3-3/0 AWG, 6 AWG CU EG, 2" CONDUIT 3-3/0 AWG, 6 AWG CU EG, 2" CONDUIT PROPOSED 200A RATED FUSIBLE DISCONNECT FUSED WITH RK1 200A FUSES, NEMA 3R = I 200A 200A PROPOSED 200A NEMA 3R ( 0) INTEGRATED LOAD CENTER (ILC) W/ ON PANEL 'PP1' 3/4" CONDUIT FOR GEN. ALARM WIRING. PROPOSED RBA72 2P-40 1P-20 I 2P-40 —0 o P-40 �0 0 2P-40 1P-20 1 P-20 I ' L- 2" POWER CONDUIT 1 1/4" CONDUIT FOR CONTROL/ALARM WIRES 200A o (� 30 KW DIESEL GENERATOR WITH 2O0A MAIN lJ BREAKER. CONTRACTOR SHALL COORDINATE WITH OWNER/TENANT FOR GENERATOR CONFIGURATIONS AND OPTIONS. COMPLY WITH MANUFACTURER'S SPECIFICATIONS FOR EXACT WIRING REQUIREMENTS. 4-12 AWG, 12 AWG CU EG, 3/4" CONDUIT NOTE: THE GENERATOR USED IN FOR GEN BLOCK CONJUNCTION WITH A 2-POLE AUTOMATIC HEATER &CHARGER TRANSFER SWITCH WITH A SOLID NEUTRAL IS NOT A SEPARATELY DERIVED SYSTEM. AS SUCH, DO NOT BOND THE NEUTRAL TO GROUND AT THE GENERATOR. 1 1 /4" TELCO CONDUIT 3/4" ALARMS / CONDUIT t- 2" FLEX CONDUIT 3/4" POWER CONDUIT 2-8 AWG, 10 AWG EG -0 0 4-8 AWG, 8-6 AWG 2P-125 THHN CU, 6-10 AWG EG 2-12 AWG, 1-12 AWG EG IN 1/2" POWER CONDUITS PROPOSED H-FRAME PROPOSED RBA72-36 PROPOSED RBS-6120 NOTE- CONNECT DC POWER PLANT IN COMMSCOPE RBA72 CABINET TO 48V BATTERY STRINGS #1, #2 AND #3 (LOWER 2 SHELVES) IN RBA72-36 BATTERY CABINET. CONNECT DC POWER PLANT IN ERICSSON RBS-6120 CABINET TO 48V BATTERY STRINGS #4, #5 AND #6 (UPPER 2 SHELVES) IN RBA72-36 BATTERY CABINET. 1 1/4" TELCO CONDUIT 3/4" ALARMS CONDUIT KEY NOTES: 2" POWER O AREA LIGHT LITHONIA CONDUIT HFR 250M SCWA DNA LP1. CONTROL VIA CONTRACTOR PROVIDED MANUAL TIMER SWITCH (WEATHERPROOF) NOTES AND SPECIFICATIONS: 1. ELECTRIC UTILITY WILL PROVIDE METER AND INCOMING SERVICE LATERAL CONDUCTORS. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH NEC, STATE, AND LOCAL CODES. 3, CONTRACTOR SHALL OBTAIN OWNER/TENANT EQUIPMENT DRAWINGS AND REVIEW FOR ADDITIONAL DETAILS AND REQUIREMENTS THAT MAY NOT BE SHOWN IN THESE DRAWINGS. CONTRACTOR SHALL COMPLY WITH ANY ADDITIONAL OWNER/TENANT SPECIFICATIONS AND REQUIREMENTS THAT MAY BE ADDRESSED IN THE EQUIPMENT DRAWINGS. 4. PRIOR TO PURCHASING EQUIPMENT, THE CONTRACTOR SHALL CONTACT THE ELECTRIC UTILITY AND OBTAIN IN WRITING THE MAXIMUM AVAILABLE FAULT CURRENT AT THE UTILITY SERVICE POINT. PROVIDE MAX AFC SIGNAGE AS REQUIRED PER NEC 110.24. THE CONTRACTOR SHALL ENSURE ALL ELECTRICAL EQUIPMENT, CIRCUIT BREAKERS, DISCONNECTS, FUSES, AND PANELBOARDS HAVE A FAULT CURRENT INTERRUPTING RATING GREATER THAN THE AVAILABLE FAULT CURRENT. IN NO CASE SHALL THE FAULT CURRENT INTERRUPTING RATING BE LESS THAN 10,000 AMPS. 5. THE GROUNDED SERVICE CONDUCTOR (NEUTRAL CONDUCTOR) SHALL BE GROUNDED AT THE SERVICE DISCONNECT ONLY. 6. ALL POWER CIRCUITS SHALL USE COPPER CONDUCTORS WITH THHN/THWN INSULATION. ALL TERMINATIONS SHALL BE RATED FOR AT LEAST 75 DEGREES C. 7. CONTRACTOR SHALL PROVIDE GROUND FAULT CIRCUIT INTERRUPTER (GFCI) TYPE RECEPTACLES. 8. CONTRACTOR SHALL ENSURE ALL NEUTRAL CONDUCTORS HAVE WHITE INSULATION AND EQUIPMENT GROUND CONDUCTORS HAVE GREEN INSULATION. COLOR TAPE IDENTIFICATION OF THESE CONDUCTORS IS NOT ALLOWED. 9. PER NEC ART. 702 PROVIDE SIGNAGE AS FOLLOWS: A) AT PANEL PP1 AND DISCONNECT: "EMERGENCY POWER IS SUPPLIED BY STAND-BY GENERATOR LOCATED ON OTHER SIDE OF PAD." 3) Al StNVIGL MiL;UNNLGI: WARNING - SHOCK HAZARD EXISTS IF GROUNDING ELECTRODE CONDUCTOR OR BONDING JUMPER CONNECTION IN THIS EQUIPMENT IS REMOVED WHILE ALTERNATE SOURCE(S) IS ENERGIZED. OPENING THE EQUIPMENT DISCONNECT WILL CAUSE THE EMERGENCY GENERATOR TO START. TO REMOVE POWER ENTIRELY FROM THE EQUIPMENT, THE GENERATOR MUST BE TURNED OFF AND THE GENERATOR BREAKER MUST BE OPENED. 2-1 AWG 6 AWG EG SINGLE -LINE DIAGRAM 2" CONDUIT E3 SCALE: NOT TO SCALE verizonv 8821 RESEARCH DRIVE CHARLOTTE, NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 07/13/16 CONSTRUCTION I =RFV_�=DATF-1.45t1F0 FORS AY--, 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM imley>>> Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, CA 30092 PHONE: 770-825-0744 WWW.KIM LEY—H ORN. COLA ® Raleigh, NC Indianapolis, IN Philadelphia, PA APOGEE Pittsburgh, Virginia Beach, VA Consulting Group, PA Fort Collins, CO YpNP✓.acg-pa.com (919) 858-7420 NC License # C-1848 ACG PROJECT NO.: 2016-169 =DRAWN BY.=CHK.:PV.: AMM I NAC I JKM =LICENSER: CA rrrl,�� SS/0".4- SEAL 23894 IIIIrur►►►► �`i;l/� SINGLE -LINE DIAGRAM E3 1 018985035 Coptright KGnll and Auodatm Ina, 2016 6" WIDE RED MAGNETIC WARNING TAPE WITH BLACK LETTERS. TAPE TO READ: CAUTION ELECTRIC LINE BURIED BELOW. IDEAL INDUSTRIES MODEL#42-251 6" LAYER OF STONE (WHERE REQUIRED) �o°o�oob5 TOP OF GROUND ROD, 30" MIN. OR 6" BELOW FROSTLINE (WHICHEVER IS DEEPER) FINISHED GRADE GROUND ROD SHALL NOT BE N ANGLED MORE THAN 30' FROM III— III—) GROUND RING VERTICAL. ANGLE AWAY FROM III I� I SHELTER OR PAD WHERE EXOTHERMIC WELD CONNECTION POSSIBLE. TREATED WITH TWO (2) COATS Z) COLD GALVANIZED PAINT 2 x COMPACTED BACKFILL 5/8" DIAMETER COPPER CLAD K— STEEL GROUND ROD 10' LONG. AT LEAST 8' OF GROUND ROD IN N M CONTACT WITH SOIL 4" TELCO CONDUIT NOTE: TYPICAL GROUND ROD DETAIL 2" POWER CONDUIT ---SPACING FOR ALL 2 UNDERGROUND 5.25" 12" 5.25' CONDUITS. E4 SCALE: NOT TO SCALE 22.5" UTILITY TRENCH DETAIL (TYP.) I E4 MONOPOLE SCALE: NOT TO SCALE TOWER I COAX GROUNDING KIT (TYPICAL) 8" DIAMETER X 36" LONG PVC ICE BRIDGE PVC CAP WITH TEST WELL. USE THREADED ' SQUARE PLUG PVC CAP WITH SQUARE PLUG PROTECTION PROTECTION PROPOSED COAX FINISH 2 AWG PIGTAIL GRADE LOWER TOWER GROUND BAR MIN. 30" WELL WITH T CLEARANCE TDSGA-BC14, SEE 1 I, DEPTH BELOW. EXOTHERMIC WELD ( /E�) CONNECTION ALLOWS FOR 24" MIN USE OF CLAMP -ON GROUND 2 AWG TINNED EARTH METERS FOR TESTING GROUND TOP OF GRAVEL COPPER SOLID ARE SYSTEM. COAX SRC No. 6 AGGREGATES R IN OR DRIP 3/4D PVC CONDUIT SRC CR-6 CRUSH RUN MIN. g" a LOOP 12" DEEP q 6" EXOTHERMIC .® ; CONNECTION I " b • e TOWER GROUND RING (MINIMUM OF 30" DRIVEN COPPER MONOPOLE CAISSON BELOW GRADE) CLAD GROUND ROD `.: b• 3/4"X10'-O" 'ae GROUND ROD TEST WELL 4 DRIP LOOP DETAIL 3 E IE4 SCALE: NOT TO SCALE SCALE: NOT TO SCALE verizon' 882f RESEARCH DRIVE CHARLOTTE, NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY CURRENT ISSUE DATE: 107/13/16 I CONSTRUCTION REV.:=DATE: ISSUED FOR: BY:, 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM ® >>> H o r 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, CA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORM.COM ® Raleigh, NC Indianapolis, IN Philadelphia, PA APOGEE Pittsburgh, Virginia Beach, VA Consulting Group, PA Fort Collins, CO �.acg-pa.com (919) 858-7420 NC License # C-1848 ACG PROJECT NO,: 2016-169 =DRAWN BY:=CHK.:APV.: AMM NAC JKM I IIIIIff,/1,/ C A R o Z .Q� N9�•.-y ; SEAL = 23894 C. V ELECTRICAL DETAILS =SHEET NUMBER: REVISION: E4 1 018985035 Cop)Ogbt KlmlelrHom and Amodcta, Inc., 2016 NOTES AND SPECIFICATIONS: 1. ALL WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE, STATE BUILDING CODES AND THE LOCAL BUILDING CODES. ALL COMPONENTS SHALL BE U.L. LISTED, 2. REFER TO SITE LAYOUT PLAN FOR THE EXACT LOCATION OF H-FRAME. 3. CONTRACTOR TO COORDINATE WITH LOCAL UTILITY COMPANY FOR METER. 4. CONTRACTOR TO PROVIDE AND INSTALL METER SOCKET. 5. CONTRACTOR TO ENSURE WORKING SPACES REQUIRED BY THE NEC (ART, 110.26), STATE, OR LOCAL CODES ARE MAINTAINED BETWEEN FRONT OF ENCLOSURES AND THE CHAIN LINK FENCE WHERE APPLICABLE. 6. SHOW LOCATION (INCLUDING DIMENSIONS) OF ALL CAPPED UNDERGROUND CONDUIT ON FINAL AS -BUILT DRAWINGS SUBMITTED TO OWNER. APPROX. 6'-0" 800A RATED 4-GANG METER CENTER. S.E. RATED, U.L. LISTED, NEMA 3R ENCLOSURE. 7. COORDINATE EXACT LOCATION OF UNDERGROUND FEEDERS AND CIRCUITRY WITH THE OWNER. 8. CONTRACTOR SHALL COORDINATE WITH LOCAL ELECTRICAL AUTHORITY HAVING JURISDICTION (AHJ) AND OTHER TRADES TO DETERMINE "FROST" LINE, AND TYPES OF RACEWAYS REQUIRED FOR INSTALLATION. 9. ABOVE GRADE CONDUITS SHOULD BE SCHEDULE 40 PVC OR SCHEDULE 80 PVC WHERE EXPOSED AND SUBJECT TO DAMAGE. 10. CONTRACTOR TO CONTACT LOCAL UTILITY PRIOR TO PURCHASING METER CENTER TO VERIFY ANY PARTICULAR REQUIREMENTS, SUCH AS LEVER BYPASS, ETC. 11. CONTRACTOR SHALL INSURE THAT NO OPERABLE DEVICE SHALL EXCEED 6'6" TO CENTER LINE OF THE DEVICE. PROVIDE GALVANIZED CAP ON TOP OF POST (TYPICAL) SEE NOTE 11 O 3 1/2" O.D. GALV. PIPE 200A METER (TYPICAL) SOCKET-UL LISTED, NEMA 3R ENCLOSURE P2860-10 CAP END O (TYPICAL) w 0 a GALV. UNISTRUT P1000 O 0 g (TYPICAL) 0 GFI RECEPTACLE IN A WEATHERPROOF HOUSING o g O WITH A HASP FOR A LOCK. 1 2/0 AWG BARE TINNED MOUNT TO RACK CO STRANDED COPPER GEC 1/2" POWER CONDUIT TO IN 3/4" PVC CONDUIT a PROPOSED ILC ON VZW H-FRAME 2" POWER CONDUIT-,\\\,—\ TO VERIZON PVC SLEEVE DISCONNECT 2 AWG BARE TINNED SOLID MIN. 24" INTO COPPER, CONNECT TO GROUND NEAREST GROUND RING AND GRADE CADWELD TO POST (TYPICAL BOTH PIPES) P. TO GROUND SYSTEM (TYP.) ° GROUND SYSTEM a �' PROVIDE 2 PARALLEL RUNS OF 3-500 kCMIL, EACH IN 4" CONDUIT, FROM POWER CO. DEMARC. 2 AWG BARE TINNED SOLID COPPER 5/8" x 10' COPPERCLAD STEEL, DRIVEN GROUND ROD 0 o NOTE: Z CONSTRUCT SO w CONCRETE FOOTING Uj EXTENDS 6" BELOW FROST LINE AND IN COMPLIANCE WITH ALL CID I LOCAL AND STATE �+ CODES. CONCRETE MIN. 30 DAY STRENGTH OF 3000 PSI H-FRAME DETAIL E5 SCALE: NOT TO SCALE verizon,l 8.921 RESEARCH DRIVE CHARLOTTE, NORTH CAROMNA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAW13A COUNTY CURRENT ISSUE DATE: 07/13/16 FCONSTRUCTION =REV.:=DATE: ISSUED FOR: RY:� 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM i * orn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY-HORN.COM ® Raleigh, NC Indianapolis, IN Philadelphia, PA APOGEE Pittsburgh, PA Virginia Beach, VA Consulting Group, PA Fort Collins, CO �.acg-pa.conn (919) 858-7420 NC License # C-1848 ACG PROJECT NO.: 2016-169 =DRAWN BY:=CHK.: AIRV.: AMM I NAC I JKM �N•CARo Q �9< . 9 SEAL 23894 ELECTRICAL DETAILS E5 1 018985035 Copp*t Khnlay-H= and M.odataa, Ina, 2018 EXTEND TO INSTALL AREA LIGHT LITHONIA HFR 250M SLWA DNA LP1 HEIGHT TBD AS REQUIRED (TYP. OF 2) NOTES AND SPECIFICATIONS: PROVIDE GALVANIZED 1. ALL WORK SHALL CONFORM TO THE NATIONAL CAP ON TOP OF POST PROPOSED ELECTRICAL CODE, STATE BUILDING CODES AND (TYPICAL) ICE BRIDGE THE LOCAL BUILDING CODES. ALL COMPONENTS SHALL BE U.L. LISTED, 2. REFER TO SITE LAYOUT PLAN FOR THE EXACT 2" POWER LOCATION OF H—FRAME. CONDUIT TO 2" POWER RBA72 CONDUIT TO 3. CONTRACTOR TO ENSURE WORKING SPACES 3/4" CONDUIT RBS-6120 REQUIRED BY THE NEC (ART. 110.26), STATE, OR 4" TELCO CONDUIT TO FOR ALARM LOCAL CODES ARE MAINTAINED BOTH ON THE RBA72 FRONT SIDE AND THE BACK SIDE OF THE APPROX. 6'-0" H—FRAME. 4. SHOW LOCATION (INCLUDING DIMENSIONS) of ALL CAPPED UNDERGROUND CONDUIT ON FINAL 1/2' POWER CONDUIT 3 1/2" O.D. GALV. AS —BUILT DRAWINGS SUBMITTED TO OWNER. TELCO BOX IN A PIPE (TYPICAL) 5. COORDINATE EXACT LOCATION OF UNDERGROUND PVC NEMA 3R ENCLOSURE 18"x18"x6" FEEDERS AND CIRCUITRY WITH THE OWNER. WITH REMOVABLE 1/2" POWER CONDUIT 6. CONTRACTOR SHALL COORDINATE EFFORTS WITH FRONT PANEL TO AREA LIGHTS (LOCAL, ELECTRICAL) AUTHORITY HAVING JURISDICTION (AHJ) AND OTHER TRADES TO w 0 0 0 o P2860-10 CAP END DETERMINE "FROST" LINE, AND TYPE(S) OF < (TYPICAL) RACEWAYS REQUIRED FOR INSTALLATION. GALV. UNINSTRUT 7. BOND ALL ELECTRICAL EQUIPMENT TO RACK. 0 PROP SED P1000 w ILC PROPOSED (TYPICAL) B. DIMENSIONS SHOWN ARE APPROXIMATE AND MAY o o DISCONNECT 0 BE ALTERED IN THE FIELD AS APPROVED BY 1 GFI RECEPTACLE IN A ENERLITES HET06 IN OWNER TO BETTER SUIT ACTUAL CONDITIONS OR o WEATHERPROOF WEATHERPROOF BOX EQUIPMENT RECEIVED. HOUSING WITH A HASP 0 WITH CLEAR PLASTIC 9. FOR ANY METAL CONDUIT ENTERING AN 0 0 FOR A LOCK. MOUNT u 0 o COVER TO RACK tt ENCLOSURE WHERE A PRE —PUNCHED CONCENTRIC 1 2' OR ECCENTRIC KNOCKOUT IS USED, THE / POWER CONDUIT CONTRACTOR SHALL ENSURE ADEQUATE BONDING 1-1/4" PVC CONDUIT BETWEEN THE METAL CONDUIT AND ENCLOSURE BY TO GENERATOR INSTALLING A BONDING JUMPER AROUND THE CONTROLS/ALARMS CONCENTRIC OR ECCENTRIC KNOCKOUT, ° ° ° ° 2" POWER CONDUIT 3/4" CONDUIT FOR BLOCK FROM SERVICE 10. CONTRACTOR SHALL INSURE THAT NO HEATER/BATTERY CHARGER DISCONNECT OPERABLE DEVICE SHALL EXCEED 6'6" TO CENTER To GENERATOR LINE OF DEVICE. 1/2" POWER CONDUIT o 0 0 0 TO GFI RECEPTACLE 2" POWER CONDUIT 4" TELCO 2" POWER CONDUIT FROM CONDUIT TO GRADE UTILITY 8• GENERATOR 6„ PROPOSED CABLE TRAY 2 AWG BARE TINNED SOLID COPPER,---------,,,,,'..:, : 1 1 • CONCRETE CONNECTED TO NEAREST GROUND EQUIPMENT PAD RING AND CADWELDED TO POST a "• (TYPICAL BOTH PIPES) I r 2/0 AWG BARE 1 i•, e.. Lj TINNED STRANDED UNISTRUT PIPE/CONDUIT CLAMP P1119 OR P2558-35 1 I •• COPPER GEC IN ®I I t° O 3 4" PVC CONDUIT I I ' (GALV) 3 1/2" 1 Z i i.' ". TO PROPOSED / I I NOTE: (TYPICAL) FOLLOW MANUF. O.D. POST `1- W ®,• i i m' • GROUND SYSTEM ° 4 i i• • ^ CONSTRUCT SO CONCRETE RECOMMENDATIONS FOR v 1 I 1 I FOOTING EXTENDS 6" BOLT TORQUE BELOW FROST LINE AND -- -- 5/8" X 10' IN COMPLIANCE WITH ALL LOCAL AND STATE CODES. STEEL DRIVEN MIN. 30 2 UNISTRUT SUPPORT DAYCRETE STRENGTH OF 1'-6" GROUND ROD E6 300o PSI SCALE: NOT TO SCALE H-FRAME DETAIL 1 E6 SCALE: NOT TO SCALE verizonv 8921 RESEARCH DRM CHARLOTTE, NORTH CAROLIIVA 28262 PROJECT INFORMATION: VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 07/13/16 I ICONSTRUCTION I =RFV •TATF• ISSI IFn W1R• RV•_ 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM imley*Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY-HORN.COM Raleigh, INC Indianapolis, IN Philadelphia, PA APOGEE Pittsburgh, Virginia Beach, VA Consulting Group, PA Fort Collins, CO �.acg-pa.conn (919) 858-7420 NC License # C-1848 ACG PROJECT NO.: 2016-169 =DRAWN BY:=CHK.:--APV.: AMM I NAC I JKM ````��111► a ►rrrrr,�' .,11'% ;�Z� •�oF ESS/0 % SEAL 23894 ELECTRICAL DETAILS E6 1 018985035 Ccp)T*t KMnlay-H— and As did.. Ina, 2016 1 E7 TINNED COPPER LONG -BARREL DOUBLE -LUG CONNECTOR (TYP.) SS SPACER (TYP.) SS BEAM CLAMP SS HARDWARE BAR NONE GROUNDED BEAM CLAMP TDSGA-BC14 GROUND BAR SCALE: NOT TO SCALE TINNED COPPER LONG -BARREL DOUBLE -LUG CONNECTOR (TYP.) 2 E7 SS HARDWARE ;PACER (TYP.) BAR NONE POST MOUNTED TINNED COPPER LONG -BARREL DOUBLE -LUG CONNECTOR (TYP.) INSULATOR SPACER (TYP.) SS HARDWARE BAR NONE INSULATED TDSGA-WB17 GROUND BAR SCALE: NOT TO SCALE 3 TDSGA-PA14 GROUND BAR E7 SCALE: NOT TO SCALE verizonit 8921 RESEARCH DRIVE CHARLOTTE, NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TED 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 1 07/13/16 CONSTRUCTION =REV.:=DATE ISSUED FOR: RY•L 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM imIey>>> Ho 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, CA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORN.COM ® Raleigh, NC Indianapolis, IN Philadelphia, PA APOGEE Pittsburgh, Virginia Beach, VA Consulting Group, PA Fort Collins, CO v .acg-pa.com (919) 858-7420 NC License # C-1848 ACG PROJECT NO.: 2016-169 =DRAWN BY:==CHK.:APV.: AMM I NAC I JKM SEAL =_ 23894 kEV I .... ►►►,,% =SHEET TITLE: ELECTRICAL DETAILS =SHEET NUMBER: REVISION: E7 1 018985035 Copyrlpht Klmlay—Ham and Asaoclotas, Ina, 2DI6 NOTES: NOTE: 1. CONNECT COAX GROUND KITS DIRECTLY TO TOWER TOP CIGBE ONLY —G PROPOSED ALL CIGBE GROUND BARS ON TOWER AS NOTED ON DETAIL 3/E8. ANTENNA (TYP) ARE TO BE ERICO TDSGA OR APPROVED EQUAL. TYPICAL USE TDSGA-WB17 ISOLATED FROM 2. FOR GROUNDING CONNECTIONS AND DETAILS, SEE SITE GROUNDING 2 AWG TCW COAX UNISTRUT BRACKET. PLAN. I — — —G CABINETS I 6 AWG INSULATED GROUND WIRE FROM GROUND CABLE KIT TYP COAX GROUND KIT TO TOWER GROUND 3. TOWER GROUND BARS WILL BE ISOLATED FROM TOWER BUT BONDED 2 AWG T GW ( (TYP) BAR TO TOWER WITH 2 AWG STC AND CLAMP (OR CADWELD) UNLESS TRAY I COAXIAL NOTED OTHERWISE. GROUNDING I c> CABLE "�'� SECTOR CIGBE GROUND BAR, POST 2 AWG TC GEN GPS 6 AWG — — — — -�,N I PROVIDE ONE PER SECTOR 4. ALL 2 AWG TCW MUST BE SOLID TINNED. ANTENNA —G (INDOOR) TYP. OF 2 NEXT TO ANTENNAS (OPTIONAL ON INSULATED I I GUYED TOWERS) AND ISOLATED FROM EQUIPMENT MAIN -OR- I I TOWER. BOND TO TOWER OR SECTOR @ 6AWG---G----G--f EXTERIOR I I FRAME WITH #2 STC AND APPROVED ABLE 1/FEEDLIN 2 AWG TCW (OUTDOOR) INSULATE GB — — —G — — — —G CLAMP. IF UNABLE TO CLAMP #2 TO @TOWER (OUTDOOR) 0 I METAL STRUCTURE THEN RUN #2 COAX GIND KIT6 AWG 2 AWG T W INTERIOR I INSULATED FROM SECTOR CIGBE TO 6 AWG INSUL. ABLE 11FEEDLIN INSULATE TOWER — — —G MGB I NEXT LOWEST CIGBE. BOTTOM — — —G I 2 AWG TCW HALO I TOWER TOP CIGBE GROUND BAR COAX GND KIT 2 AWG TCW — — —G CABLE 11FEEDLINE INTERMED. (MONOPOLE) I MOUNTED TO TOWER WHERE COAX CIGBE-SEE 2 AWG TCW HVAC UNITS I CABLES LEAVE VERTICAL WAVE GUIDE #2 AWG (SEE DETAIL NOTE 3 C.#2 AWG (SEE OR — — —G SUPPORT OR COMMON CABLE TRAY. ............ 6 AWG INSUL. 21E9, NOTE 2) I I DETAILS 21E9. I I TYPICALLY OCCURS ON GUY TOWERS NOTE 2) GOUNDING 2 AWG TCW TIE DOWN I (IN LIEU OF SECTOR CIGBE'S) SEE NOTE1 TOWER ACTS AS POST — —G I I PLATES � ROOFTOPS, OR ON WATER TANKS IN KIT CABLE CONDUCTOR (LATTICE) 0 I ORDER TO MAINTAIN 75FT MAXIMUM COAX GND I I DISTANCE BETWEEN COAX GROUND TOWER TOP 1/FEEDLINE I KITS. ISOLATE CIGBE FROM TOWER (AS CIGBE -SEE TOWER 2 AWG TCW I (INDOOR) AND BOND TO TOWER WITH #2 STC NOTE 3 GROUND — — —G — — — —G # I REQUIRED � RING I � AND APPROVED CLAMP. IF UNABLE TO CLAMP #2 TO METAL STRUCTURE THEN #2 AWG (SEE co I RUN #2 INSULATED FROM SECTOR I AWG DETAIL 21E8, ' AGROUND RING 2 AWG i CIGBE TO NEXT LOWEST CIGBE. INSUL. NOTE 2) / I � / TCW 30" BELOW GRADE UTILITY _ 2 AW SECTOR RACK TC c� I 1 ICE BRIDGE I CIGBE -SEE NOTE3 AWG I TCW G Q I I TCW -OR-I I 6 AWG INSULATED GROUND WIRE N 12 AWG ICE BRIDGE I FROM COAX GROUND KIT TO TOWER GATE GATE POST FENCE I I TCW POSTS i GROUND BAR CORNER COAX GROUND I _ OR - KIT (TYP) —G � I INTERMEDIATE CIGBE GROUND BAR — — —G — — — —G ( MOUNTED TO TOWER BELOW AND WITHIN 2 AWG 2 AWG TCW MIDPOINT GROUND 3FT OF COAX GROUND KITS AND TCW 2 AWG TCW AS I EVERY 75FT. ISOLATED FROM TOWER. BOND TO TOWER GROUND REQUIRED MAXIMUM EXCEPT WITH #2 STC AND APPROVED CLAMP. IF RING FENCE 2 AWG TCW WHERE CABLES RUN UNABLE TO CLAMP #2 TO METAL OUTSIDE — — —G INSIDE MONOPOLE STRUCTURE THEN RUN #2 INSULATED COMPOUND (AS REQUIRED) OR OTHER POWER FROM SECTOR CIGBE TO NEXT LOWEST II 0— — — INACCESSIBLE SPACE CIGBE. 2 GROUNDING SYSTEM SINGLE LINE DIAGRAM COAX 6 AWG INSULATED GROUND WIRE FROM E$ GROUND COAX GROUND KIT TO TOWER GROUND SCALE: NOT TO SCALE KIT (TYP) BAR 6 AWG FROM ANTENNA COAX GROUNDING KIT. (FOR TOWER TOP TO SHELTER TOWER BOTTOM GROUND BAR CIGBE'S OCCURS ONLY ON GUYED TOWERS, OR ON OTHER OR CABINETS TDSGA-PA14 ON DEDICATED STEEL POST CIGBE GROUND BARS ON ANTENNA STRUCTURES WHERE REQUIRED TO ACHIEVE 75FT MAXIMUM WHERE POSSIBLE. OTHERWISE TOWER. ISOLATE FROM TOWER. ISOLATE DISTANCE BETWEEN COAX GROUNDING LOCATIONS) TDSGA-BC14 CLAMPED DIRECTLY TO FROM TOWER TOWERS STEEL. NOTES' GROUND RING 2 AWG GROUND WIRE WHEN USING TDSGA-BC14. TYPICAL TWO 1. ALL CIGBE GROUND BARS ON TOWER ARE FINISHED GRADE CONNECTIONS TO GROUND RING TO BE ERICO TDSGA. TYPICALLY USE TDSGA-WB17 — — — —G — — — — — — — — —G — — — —G — ISOLATED FROM UNISTRUT BRACKET. 2, IF CIGBE CANNOT BE BONDED DIRECTLY TO TOWER AND ® O COAX/TOWER GROUNDING CANNOT BE CONNECTED TO TOWER WITH 2 AWG AND CLAMP (OR CADWELD). THEN RUN 2 AWG BLACK O 0 O INSULATED GROUND LEAD FROM CIGBE DOWN TO NEXT , S C HE MATI C LOWER CIGBE. SECURE GROUND LEAD WITH 0 0 0 0 0 0 NON-METALLIC TIES AT SAME SPACING AS COAX E$ SUPPORTS. 2 AWG-RUN FROM SCALE: NOT TO SCALE ANTENNA GROUND WIRE INSTALLATION CIGBETo CLTOWER 3 RUN INSULATED TO E8 NEXT LOWER CIGBE SCALE: NOT TO SCALE verizon,' 8821 RHSSARCH DRIVE CHARL02TE, NORTH M0,12HA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY :CURRENT ISSUE DATE: 07/20/16 CONSTRUCTION :RFV •-r1ATF• ISSI IFn Fr7R• RV•C 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM 2 07/20/16 CONSTRUCTION JKM in m/ Hor 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, CA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORN.COM ® Raleigh, NC Indianapolis, IN Philadelphia, PA APOGEE Pi h, PA Virginiaginia Beach, VA Consulting Group, PA Fort Collins, CO w .acg-pa.com (919) 858-7420 NC License # C-1848 ACG PROJECT NO.: 2016-169 :DRAWN BY:=CHK.: APV.; AMM I NAC I JKM Q 4q� . 9 SEAL 23 94 C: 77/111111111 ` 11 ELECTRICAL DETAILS /2� E8 2 018985035 Copw*t XWey-Ham and A—datm Ina, 2018 LOAD SERVED KVA /Phas CKT BRKR CKT NO NEUTRAL A B CKT NO CKT BRKR KVA/Phase LOAD SERVED A B A A GEN BLOCK HEATER 0.50 --- 1P-20 1 2 2P-40 2.84 -- RBA 72 AREA LIGHTS --- 0.60 1P-20 3 4 --- 2.84 GFCIRECEPTACLE 0.18 --- 1P-20 5 6 2P-40 2.84 RBA 72 GFCI RECEPTACLE -- 0.18 1P-20 7 8 --- 2.84 GEN CHARGER 0.10 --- 1P-20 9 10 2P-40 2.84 RBA 72 SPARE -- 0.00 1 P-20 11 12 -- 2,84 SPARE 0.00 --- 1P-20 13 14 2P-40 0.00 --- RBA 72 (FUTURE) SPARE -- 0.00 1P-20 15 16 --- 0.00 SPARE 0.00 -- 1P-20 17 18 1P-20 18 --- GFCI RECEPTACLE SPARE --- 0.00 1P-20 19 20 1P-20 0.18 GFCI RECEPTACLE SPARE 0.00 -- 1P-20 21 22 2P-125 j3.95 RBS 6120 (3 PSU's) SPARE -- 0.00 1P-20 23 24 - 3.95 SPARE 0.00 -- 1P-20 25 26 1P-20 00 --- SPARE SPARE -- 0.00 1 1P-20 27 28 1P-20 --- 0.00 SPARE SPARE 0.00 --- 1P-20 29 30 1P-20 0.00 --- ISPARE SPARE --- 0.00 1P-20 31 32 1P-20 --- 0.00 SPARE SPARE 0.00 --- 1P-20 33 34 1P-20 0.00 -- SPARE SPARE --- 0.00 1P-20 35 36 1P-20 --- 0.00 SPARE SPARE 0.00 --- 1P-20 37 38 1P-20 0.00 -- SPARE TVSS -- 0.00 2P 30 39 40 1P-20 -- 0.00 SPARE 0.00 --- 41 42 1 1P-20 0.00 -- SPARE SUB TOTAL 0.78 1 C/B TEMP. 75 C. RATING 120 MOUNTING SURFACE, NEMA 3R MAIN CIRCUIT BREAKER ISOLATED GROUND BUS MNO ED SERVICE ENTR. RAT MINIMUM AIC (K AMPS) 22 MCB RATING MLO BUS RATING 200A NEUTRAL RATING 100% 0.78 240 V 1 PH 3 12.35 12.65 13.43 13.43 ITOTAL CONNECTED KVA CONNECTED SUB TOTAL NEC DEM FACTOR DEMAND KVA LOAD TYPE B A B GENERAL LIGHTING 0.00 0.60 125% 0.00 0.75 GENERALUSE RECEPT 0.36 0.36 <_10 KVA@100% 0.36 0.36 >1UKVA@50% 0.00 0.00 MOTORS AND EQUIPMENT LARGEST 3,95 3.95 125% 4.94 4.94 JALL OTHERS 9.12 8.52 100% 9.12 8.52 EXTERIOR LIGHTING 0.00 0.00 125% 0.00 0.00 DEDICATED RECEPT 0.00 0.00 100% 0.00 0.00 SIGN 0.00 0.00 125% 0.00 0.00 FIX ELEC. SPACE HEAT 0.00 0.00 100% 1 0.00 0.00 TOTAL KVA PER PHASE 13.43 13.43 14.42 14.57 TOTAL DEMAND AMPERES PER PHASE 120 121 PANEL / FEEDER (TOTAL KVA) 28.99 PANEL 'PP1' (PROPOSED ILC) (TOTAL KVA) X 1000 = TOTAL AMPS VOLTS 121 PANEL SCHEDULE E9 SCALE: NOT TO SCALE verizom' 8821 W& RCH DRIVE CHARLOTTE, NORTH CAROLINA 28262 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY ::CURRENT ISSUE DATE: 07/13/16 CONSTRUCTION =REV.:=DATE: ISSUED FOR: BY:= 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM imley>>> Horn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, GA 30092 PHONE: 770-825-0744 WWW.KIMLEY-HORN.COM ® Raleigh, NC Indianapolis, IN Philadelphia, PA APOGEE Pittsburgh, Virginia Beach, VA Consulting Group, PA Fort Collins, CO �.acg-pa.com (919) 858-7420 NC License # C-1848 ACG PROJECT NO.: 2016-169 =DRAWN BY,=CHK.: AIRV.: AMM I NAC I JKM C A R 0� =per �oF ESS/0 SEAL = 23894 ELECTRICAL DETAILS /1� E9 1 ) 01B985035 copyright Klmley-Ham and Meodatee, Ina, 2016 NOTE; RUN CONDUITS DOWN FROM H-FRAME, ACROSS SLAB ON CABLE TRAY AND INTO CONDUIT AREA OF GENERATOR. CUT OPENING IN BOLT -ON PANEL AT END OF GENERATOR AT ALLOW PASSAGE OF CONDUITS, BUT MAINTAIN CAPABILITY TO REMOVE AND REPLACE PANEL, AND KEEP OUT INSECTS AND VERMIN. COORDINATE EXACT DETAILS OF OPENING WITH VZW CM. EDGE OF SLAB GENERATOR 3'-6" 8-DIAMOND PLANK GALV. STEEL 12 GAUGE GRIP STRUT SECTION BY B-LINE OR EQUAL 3/4" CONDUIT 1-1/4" CONDUIT ABRASIVE NOSING SURFACE EACH END PLATE WASHER NEW CONCRETE SLAE APPROVED PIP] CONNECTOR EA PIPI (TYP) B2000 SERIES OR EQUAL SECTION COORDINATE EXACT LAYOUT IN FIELD WITH CONDUIT ENTRANCE TO GENERATOR 8-DIAMOND PLANK PLAN LAYOUT GALV. STEEL 12 GUAGE GRIP STRUT SECTION BY B-LINE OR EQUAL TREAD PLATES TO FINISH ENDS OF SECTION 3/8" GALV. THRU BOLT --I 3/8" GALV. BOLT WIT PROPER WASHER AND SPRIN NUT (TYP 4 PER UNISTRUI 3/8" HILTI ROD WITH HY150 ADHESIVE 2-1/2" INTO CONCRETE SLAB 1 CABLE TRAY DETAIL E10 SCALE: NOT TO SCALE ONDUIT SEE ENLARGED SECTION 1/E10 /8" X 1-5/8" X JNISTRUT (GALV) 19-1/4" L (TYP 2 STICKS) WITH VINYL END PROTECTORS UNISTRUT P1325-HG CLIP ANGLE verizon,' 8821 RESEARCH DRIVE CHARLOTTE, NORTH CAROMNA 28282 VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER. NC 28037 CATAWBA COUNTY =CURRENT ISSUE DATE: 07/13/16 ICONSTRUCTION =REV.: DATE: ISSUED FOR: BY:= 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM r "11 ke awl r >)) Morn 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, CA 30092 PHONE: 770-825-0744 WWW.KIMLEY—HORN.COM ® Raleigh, NC Indianapolis, IN Philadelphia, PA APOGEE Pittsburgh, Virginia Beach, VA Consulting Group, PA Fort Collins, CO www.acg-pa.com (919) 858-7420 NC License # C-1848 ACG PROJECT NO.: 2016-169 =DRAWN BY:=CHK.:_ APV.:_ AMM I NAC JKM ```111111I11/r1I/I' ���` CARo FESS/O". SEAL =_ 238914 �'. I N kEvI N 'II111111111111� ELECTRICAL DETAILS EE 10 1 018985035 Coplright Klmley-Ham and Aseodatee, Ina, tole GRn rt�ril Nnl��r PCIuF��A��Q� 16. BOND EACH COMMSCOPE RBA72 CABINET AND EACH ERICSSON 6120 CABINET TO GROUND ' }I� inMInl OF 02 AWG BARE SOLID TINNED COPPER (STC) RING WITH #2 AWG TINNED SOLID BARE COPPER CONDUCTOR LUGGED TO CABINET GROUND BAR CONDUCTOR, UNLESS NOTED OTHERWISE, BURIED AT 30" BELOW FINISHED GRADE (OR BELOW AND EXOTHERMICALLY WELDED TO GROUND RING. RUN GROUND LEAD IN FLEX CONDUIT ACROSS verizonl/ FROST LINE). LOCATE 24" MINIMUM AND 36" MAXIMUM FROM EQUIPMENT PAD AND FROM TOWER CONCRETE PAD BELOW CABLE LADDER, THEN DOWN INTO GRAVEL AREA. CONNECT FLEX 8821 RESEARCH DRIVE FOUNDATION. ALL CONNECTIONS SHALL BE MADE USING A PARALLEL TYPE EXOTHERMIC WELD, CONDUIT TO CABINET AT FACTORY KNOCKOUT (RBA72) OR PLINTH COVER PLATE (6120) WITH CHARLOTTE, NORTH CAROLINA 28262 UNLESS NOTED OTHERWISE. POSITIVE MECHANICAL FLEXIBLE CONDUIT FITTING. 2.INSTALL GROUND RODS AS SHOWN AND AS REQUIRED. GROUND RODS TO BE COPPER CLAD STEEL, 5/8" DIAMETER AND 1OFT IN LENGTH. SPACING BETWEEN GROUND RODS SHALL BE 10FT MINIMUM AND 15FT MAXIMUM. TOP OF GROUND ROD TO BE 30" MINIMUM BELOW GRADE (OR BELOW FROST LINE). BOND TOP OF GROUND ROD TO GROUND WIRE WITH EXOTHERMIC WELD. DO NOT EXOTHERMICALLY WELD ANYTHING TO GROUND ROD EXCEPT GROUND WIRE WHICH PASSES OVER TOP OF GROUND ROD (CLAMPED CONNECTIONS TO GROUND ROD PER TOWER MANUFACTURERS DETAILS ARE ACCEPTABLE). 3. EQUIPMENT GROUND RING SHALL HAVE A MINIMUM OF 4 GROUND RODS, INSTALLED AT THE CORNERS OF THE GROUND RING PLUS ADDITIONAL RODS AS REQUIRED TO COMPLY WITH THE SPACING REQUIREMENTS. TOWER GROUND RING SHALL HAVE A MINIMUM OF 3 GROUND RODS, EXCEPT USE 4 RODS AT A MONOPOLE TOWER. 4. EQUIPMENT GROUND RING AND TOWER GROUND RING SHALL BE BONDED TOGETHER WITH TWO #2 STC GROUND LEADS, TYPICALLY ONE ON EACH SIDE OF ICE BRIDGE. 5. BOND TOWER TO TOWER GROUND RING AT THREE LOCATIONS WITH #2 STC GROUND LEAD. SELF SUPPORT TOWERS SHALL HAVE EACH LEG BONDED TO GROUND RING, MONOPOLES AND GUYED TOWERS SHALL HAVE GROUND LEADS EQUALLY SPACED AROUND TOWER. EXOTHERMICALLY WELD GROUND LEADS TO TOP OF BASE PLATES, OR ATTACH TO TOWER USING TOWER MANUFACTURER PROVIDED DETAIL. 6. PROVIDE #2 STC RADIALS FROM THE TOWER GROUND RING TO EACH FENCE CORNER POST, RADIALS SHALL HAVE GROUND RODS AS PER THE REQUIRED SPACING. THE GROUND ROD AT THE END OF EACH RADIAL SHALL BE 24" MAXIMUM FROM FENCE CORNER POST. 7. MINIMUM BEND RADIUS FOR #2 AWG GROUND WIRE IS 12", EXCEPT USE 24" FOR TOWER GROUND RINGS AND EQUIPMENT PAD GROUND RINGS. 8. GROUND ALL EXTERIOR EXPOSED METAL OBJECTS. USE TWO HOLE LUGS FOR CONNECTION TC FLAT METAL SURFACES. USE ONLY STAINLESS STEEL HARDWARE ON ALL MECHANICAL CONNECTIONS. CLEAN ALL SURFACES (AND STRIP PAINTED SURFACES) TO BARE BRIGHT METAL PRIOR TO MAKING GROUND CONNECTIONS. APPLY ANTI —OXIDE COMPOUND TO ALL CONNECTIONS. APPLY ZINC RICH PAINT (COLD GALV.) TO ALL EXOTHERMIC WELDS, AND TO ANY METAL EXPOSED BY CLEANING, STRIPPING, GRINDING, CUTTING OR DRILLING. 9. ALL GROUNDING CONDUCTORS ABOVE GRADE SHALL BE RUN IN 3/4" FLEXIBLE PVC CONDUIT. CONDUIT SHALL BEGIN WITHIN 3/4" OF ABOVE GROUND CONNECTION POINT, SHALL EXTEND 24" BELOW GRADE MINIMUM, AND SHALL BE FILLED WITH SEALANT AT ABOVE GROUND CONNECTION POINT. SECURE CONDUIT EVERY 24" ON VERTICAL RUNS AND EVERY 36" ELSEWHERE WITH NON—METALLIC TIES. 10. WHERE POSSIBLE, MOUNT TDSGA—PA14 TOWER BOTTOM GROUND BAR ON DEDICATED POST BELOW COAX CABLES COMING OFF TOWER. WHERE INSTALLATION OF POST WOULD PUT TOWER BOTTOM GROUND BAR TOO FAR FROM COAX GROUND KITS, CLAMP TDSGA—BC14 TOWER BOTTOM GROUND BAR DIRECTLY TO TOWER STEEL (USUALLY OCCURS ON MONOPOLE TOWERS) AND BOND TO TOWER GROUND RING WITH TWO #2 STC LEADS LUGGED TO GROUND BAR AND EXOTHERMICALLY WELDED TO GROUND RING. 11. AT EQUIPMENT PAD, SUSPEND TDSGA—WB17 EXTERIOR GROUND BAR FROM ICE BRIDGE AND ISOLATE FROM ICE BRIDGE. BOND GROUND BAR TO EQUIPMENT GROUND RING WITH TWO #2 STC LEADS LUGGED TO GROUND BAR AND EXOTHERMICALLY WELDED TO GROUND RING. RUN LEADS DOWN NEAREST ICE BRIDGE POST AND SECURE TO POST WITH NON—METALLIC TIES EVERY 24 INCHES. 12. ALL ICE BRIDGE SECTIONS ARE TO BE JUMPERED TOGETHER WITH #2 WIRE, EITHER BARE TINNED COPPER OR GREEN INSULATED STRANDED. ICE BRIDGE SHALL BE GROUNDED AT EACH END WITH #2 STC WIRE LUGGED TO ICE BRIDGE AND EXOTHERMICALLY WELDED TO UPPER PORTION OF NEAREST ICE BRIDGE POST. 13. BOND EACH ICE BRIDGE POST TO GROUND RING WITH #2 STC LEAD. EXOTHERMICALLY WELD #2 TO ICE BRIDGE POST BELOW TOP OF GRAVEL. EACH POST TO HAVE SEPARATE GROUND LEAD — DO NOT DAISY CHAIN POSTS TOGETHER. 14. BOND EACH H—FRAME POST TO NEAREST PORTION OF GROUND SYSTEM WITH #2 STC LEAD. EXOTHERMICALLY WELD #2 TO H—FRAME POST BELOW TOP OF GRAVEL. 15. BOND SURFACE MOUNTED CABLE TRAY TO GROUND RING WITH #2 STC LEAD LUGGED TO SIDE OF GRIP STRUT CABLE TRAY COVER AND EXOTHERMICALLY WELDED TO GROUND RING. 17. BOND EACH COMMSCOPE RBA72-36 BATTERY CABINET TO GROUND RING WITH #2 AWG TINNED SOLID BARE COPPER CONDUCTOR LUGGED TO CABINET BODY AND EXOTHERMICALLY WELDED TO GROUND RING. RUN GROUND LEAD IN FLEX CONDUIT ALONG BACK OF RBA72 CABINET, ACROSS CONCRETE PAD BELOW CABLE LADDER, THEN DOWN INTO GRAVEL AREA. CONNECT TWO HOLE LUG TO BACK OF CABINET AT FACTORY PROVIDED GROUNDING STUDS. 18. BOND GENERATOR TO GROUND RING WITH #2 STC AT TWO DIAGONALLY OPPOSITE LOCATIONS BY DRILLING AND BOLTING TWO HOLE LUG TO FINS ON GENERATOR BASE STRUCTURE. GROUND LEADS SHOULD RUN ALONG BASE OF GENERATOR AND TAKE SHORTEST PATH ACROSS CONCRETE PAD TO GRAVEL AREA, THEN CONTINUE TO GROUND RING. 19. BOND GPS ANTENNA AND GPS ANTENNA MOUNT TO TSDGA GROUND BAR ON ICE BRIDGE WITH #2 GREEN INSULATED STRANDED GROUND WIRE, 20. PROVIDE TWO GROUND RODS OUTSIDE GATES OF COMPOUND. DISTANCE BETWEEN GROUND RODS SHALL MATCH WIDTH OF GATE OPENING, AND DISTANCE FROM FENCE SHALL MATCH LENGTH OF LONGEST INDIVIDUAL GATE LEAF. BOND GATE POSTS TOGETHER WITH #2 STC LEAD WHICH RUNS PAST AND CONNECTS TO GROUND RODS OUTSIDE GATES. 21. BOND EACH GATE POST WITH #2 STC TO NEAREST PORTION OF GROUNDING SYSTEM INSIDE COMPOUND. 22. BOND EACH GATE TO GATE POST WITH FLEXIBLE INSULATED OR BRAIDED #4/0 COPPER STRAP. EXOTHERMICALLY WELD STRAP TO BOTH GATE AND GATE POST. 23. ANY FENCE POST WITHIN 6FT OF A GROUNDED METAL OBJECT SHALL BE BONDED TO THE NEAREST GROUND RING. ANY FENCE WITHIN 6FT OF A GROUND RING SHALL HAVE THE LINE POSTS BONDED TO THE GROUND RING AT 20FT MAXIMUM INTERVALS AS MEASURED ALONG THE LENGTH OF THE FENCE. 24. NOTIFY VZW CM TO INSPECT GROUND RING BEFORE BACKFILLING. CONTRACTOR SHALL HIRE A 3RD PARTY TO PERFORM AN IEEE81 FALL OF POTENTIAL METHOD GROUND TEST. MAXIMUM ALLOWABLE RESISTANCE TO GROUND IS 5 OHMS. PROVIDE ADDITIONAL GROUND SYSTEM COMPONENTS AS REQUIRED TO ACHIEVE THIS VALUE. 25. REFER TO TOWER GROUNDING DIAGRAM AND NOTES FOR GROUND SYSTEM REQUIREMENTS ON THE TOWER. 26. GROUNDING OF ALL ELECTRICAL EQUIPMENT SHALL BE AS PER NEC, MUNICIPAL AND UTILITY COMPANY REQUIREMENTS. VERIZON NAME: GRASSY CREEK VERIZON No.: TBD 4747 GRASSY CREEK ROAD DENVER, NC 28037 CATAWBA COUNTY CURRENT ISSUE DATE: 07/13/16 CONSTRUCTION =REV.:=DATE: ISSUED FOR: BY 0 05/16/16 CONSTRUCTION JKM 1 07/13/16 CONSTRUCTION JKM m-I& ley.pw Ho 2 SUN COURT, SUITE 450 PEACHTREE CORNERS, CA 30092 PHONE: 770-825-0744 WWW.KIMLEY-HORN.COM ® Raleigh, NC Indianapolis, IN Philadelphia, PA APOGEE Pittsburgh, PA Virginia Beach, VA Consulting Group, PA Fort Collins, CO w .acg-pa.com (919) 858-7420 NC License # C-1848 ACG PROJECT NO.: 2016-169 =DRAWN BY:=CHK.:APV.: AMM I NAC JKM ESS/pN.'/�' •Q q�• v SEAL =_ 23894 N ELECTRICAL DETAILS E11 1 018985035 Copyright Klmlay-Hom and Auodotm Inc., 2016