Loading...
HomeMy WebLinkAboutWQ0041241_Application (FTSE)_20191112Permit Number W00041241 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRule Permitted Flow Facility Facility Name Waterleaf at Leland Apartments Location Address Owner Owner Name Brunswick Regional Water and Sewer H2go Central Files APS _ SWP 10/14/2019 Permit Tracking Slip Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County Brunswick Facility Contact Affiliation Owner Type Government - County Owner Affiliation Robert Walker PO Box 2230 Dates/Events Leland NC 28451223 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 10/14/2019 Regulated Activities Requested (Received Events Additional information requested Additional information received Outfall Goggle Maps 34-12'30.7"N 78-01'07.4"W 7 aoum mate ttann Mag„a P © , Arby's �e P T," oP O OG Applebee's Grill+Bar Murphy USA 4? PT's Olde 2�,07 x. W yx �Fashioned Grille W 0 d oar �P n P"e V Dunkin' e� a awe G r,- McDonald's Walgreens San Felipe Mexican Q Salon & Spa 4 Y Burgers Leland Deli &Bagel Shops at West Gate Shakes Bur 8 Fries a y Restaurants BP o, �.��' ocze Bella's Consignment P x Select Bank & Trust Boutique liday inn 'se P Walmart Supercenter o eland.., r °o QWestgate Marketplace x SunTrust© Woodforest eq ya9 °c„ 9 National Bank© Gainey, Byrd & Dunn P Nest Western Plus - Insurance Group, Inc El Westgate Inn &Suites ac WGawt", El e9r �G� A WGateV m vd ea Phyr�yton Brunswick Point G9abgle 4 0 Westgate Senior Q Apartments .g Gate or m � wear"Di a m Map data 02019 200 ft 10/14/2019 NORMS & TUNSTALL CONSULTING ENGINEERS P.C. 1900 Eastwood Rd., Suite #11 Wilmington, NC 28403 (910) 343-9653 (910)343-9604 Fax John S. Tunstall, P.E. T. Jason Clark, P.E. September 17, 2019 SF Dean Hunkele NCDEQ —Water Quality Division Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Re: Gravity Sewer Extension Fast -Track Permit Application Waterleaf at Leland N&T Project No. 19052 Dear Mr. Hunkele, 1429 Ash -Little River Road Ash, NC 28420 (910) 287-5900 (910) 287-5902 Fax J. Phillip Norris, P.E. Thomas J. Scheetz, E.I. CI UVE., OCT 14 2019 Enclosed is the original application form, a copy of the Sewer Narrative, the original Flow Tracking / Acceptance Form (FTSE 04-16) from Brunswick Regional Water & Sewer H2GO, two (2) 8'/2 x 11 color USGS Topographic Maps, two (2) site plans (ledger size) and a $480.00 check (Norris Ck# 1443) for the processing fee. Please review this information for approval and contact us with any questions or comments you may have. Thank you for your assistance on this project. Sincerely, NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C. J. P fillip N s, P.E. aZ J /ttw 052 09-17-19 s-swr fta Itr Enclosures cc: Seth Peterson NCBELS License C-3641 State of North Carolina DW4Department � Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Divislon of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: A6.116q (to be completed by DwR) All items must be completed m- the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: H2GO Brunswick Regional Water & Sewer (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ® Other 3. Signature authority's name: Bob Walker per 15A NCAC 02T .0106(b) Title: Director C E B @+ E 4. Applicant's mailing address: P.O. Box 2230 City: Leland State: NC Zip: 28451-_ our 14 2019 5. Applicant's contact information: BY. Phone number: (9UO 371-<L949 Email Address: bwalker@b2goonline.com If. PROJECT INFORMATION: 1. Project name: Waterleaf at Leland 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W000_ and issued date: If new construction but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: Brunswick 4. Approximate Coordinates (Decimal Degrees): Latitude: 34 21 ° Longitude: -78 01' 5. Parcel ID (if applicable): 0470002432 (or Parcel ID to closest downstream sewer) Ill. CONSULTANT INFORMATION: 1. Professional Engineer: J. Phillip Norris License Number: 11966 Firm: Norris & Tunstall Consulting Engineers, Y.C. Mailing address: 1429 Ash -Little River Rd City: Ash State: NC Zip: 28420- Phone number: 210 287-5900 Email Address: pnorris@ntengineers.com IV. WASTEWATER TREATMENT FACILITY (W WTF) INFORMATION: 1. Facility Name: Belville WWTP Permit Number: NCO075540 Owner Name: Brunswick Regional Water & Sewer. H2GO V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than W W'TF): 1, PermitNumber(s): W00017916 System Wide Collection System Permit Number(s) (if applicable): WQCS00202 Owner Name(s): Brunswick Regional Water & Sewer_ H2GO FORM: PTA 04-16 Page I of Vt. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No NN/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No NN/A 3. if the Applicant is a Home/Property Owners' Association has an Operational Agreement FORM: FICA) been attached? ❑ Yes ❑No NN/A 4. Origin of wastewater: (check all that apply) ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash N Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial 0 % Commercial g_ % Industrial (See 15A NCAC 02T .0103(20)) 9•Is there a Pretreatment Program in effect? ❑ Yes N No 6. Hasa flow reduction been approved under 15A NCAC 02T .0l 14(f)? N Yes ❑ No ➢ if yes provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0t 14(t)) Daily Design Flow °" No. of Units Flow 1 bedroom units 140 gal/day 96 13,440 GPD 2 bedroom units I40 gal/day 128 17,920 GPD 3 bedroom units 210 gal/day 24 5,040 GPD Clubhouse 1,200 gal/day 1 1,200 GPD gal/ GPD gal/ GPD Total 37,600 GPD a See 15A NCAC 02T .0114(b), (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A11). b Per 15A NCAC 02T .0l 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 37,600 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC (Gravity Sewersi: 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material - 8 -- 1,500--- PVC -_.-- ➢ Section II & Ill of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section Ili contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (If Applicable)-02T.0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: _ millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): __ _ gallons per minute at _ feet total dynamic head ('I'DI1) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(I ): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(13): ➢ Required for all pump stations with an average daily now greater than or equal to I5,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 ix. SETBACKS & SEPARATIONS — (02B.0200 & 15A NCAC 02T.0305(f)): I. Does the project comply with all separations found in I SA NCAC 02T .0305(f) & (g) ➢ 15A NCAC 021'.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Re aired Storm sewers and other utilities not listed below (verdeiri Water mains vertical -water over sewer including in benched trenches 24 inches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer) 18 inches _ Reclaimed water lines horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class If impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, IIQW, or SR from normal high water or tide elevation) and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet _ _ Any basement Top slope of embankment or cuts of 2 feet or more vertical height 10 feet 10 feet Drainage systems and interceptor drains _ 5 feet Any wimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T 0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ❑ Yes ❑ No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters ➢ Information can be obtained from the 401 & Buffer Permittin B� ranch 5. Does project comply with 15A NCAC 02T.0105 c 6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per I5A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion drat undermines or deteriorates the sewer. ❑ Yes ® No ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: attest that this application for (Professional Engineer's name from Application Item Ill.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. ..,.nnn,o.. North Carolina Professional Engineer's seal, signature, and Applicant's Certification per 15A NCAC 02T .0106(b): tree or (Signaturarity's name & title from Application Item 1.3.) C47 attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I. understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater fiom this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: ,f6�'� "-.G Date: 6— FORM: FTA 04-16 Page 5 of 5 Dlvislon of Water Resources r34 Rosa State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for SewerExtension Applications (FTSE 10-18) Entity Requesting Allocation: Brunswick Regional Water & Sewer Project Name for which flow is being requested: Waterleaf at Lealnd More than one FTSE umy be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Belville WWTP b. WWTP Facility Permit #: NCO075540 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used U11 .0376 1.0086 252 are in - OCT 14 2019 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) ()))=(B+C) (E)=(A-D) Design Approx. Average Current Obligated, Total Pump Pump Daily Avg. Not Yet Current Station Station Finn Flow** Daily Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Flow, Daily Flow, Obligated Available Number) No. MOD MOD MOD MOD Flow Capacity*** 36 W00017916(M) .626 .251 .079 .083 .191 .059 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Brunswick Regional Water Sewer Downstream Permit Number: W00017916(M) Page 1 of 6 FTSE 10-18 III. Certification Statement: 1 Bob Walker certify to the best of my knowledge that the addition of the Volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the plamring assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signature Title ofSigning Official. Page 2 of 6 FTSE 10-18 SEWER NARRATIVE WATERLEAF AT LELAND LELAND, NC FOR WATERLEAF AT LELAND APARTMENTS, LLC 35 BRENDAN WAY GREENVILLE, SC 29615 (864-679-4799) September 2019 Prepared by: NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C. 1429- Ash — Little River Road Ash, North Carolina 28420 (910) 287-5900 (910) 287-5902 (Fax) License # C-3641 N&T Project No. 19052 Ik,FAVNakILTA z SEWER SYSTEM: This public sewer system is designed to service a 1,2, and 3, bedroom Apartments and Clubhouse. A total of 1,495 LF of 8-inch gravity sewer line will be needed to complete the system. There are no proposed sewer pump stations. This system will be served by the Brunswick Regional Water and Sewer, H2GO.