Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0041229_Application (FTSE)_20190930
DWR Division of Water Resources State of North Carolina Department of Environmental Quality Dii,ision of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: W 00+ ( u nu he compleled h� M R1 All items must he completed or the application will he returned 1. APPLICANT INFORMATION: I. Applicant's name: To%%n of Fuaua%-Varina (compan), municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State County © Municipal 3. Signature authority's name: Jay T. Mevers, PE per 15A NCAC 02T .0106t bl Title: Public Utilities Director 4. Applicant's mailing address: 401 Old Honeycutt Road City., Fuyuay-Varina State: NC Zip: 27526-9307 5. Applicant's contact information: Phone number: (919) 567-3911 Email Address: ime+ers iitifuquay-varina.org 11. PROJECT INFORMATION: ❑ Privately -Owned Public Utility ❑ Other 1. Project name: Forest Bluff Estates Subdivision 6 ?. Application Project status: ❑X Proposed (Ne++ Permit) ❑ Existing_ Permit. Project if a modification. provide the existing permit number: WQ00 and issued date: _ If new construction but part of master plan. provide the existing permit number: WQ00 3. County ++here project is located: Wake 4. Approximate Coordinates (Decimal Degrees): Latitude: .15.618880 Longitude:-78.742262 5. Parcel ID (if applicable): 0677688748 (or Parcel ID to closest downstream sewer) ill. CONSULTANT INFORMATION: I. Professional Engineer: Andrew Petty, PE License Number: 36823 Firm: The Curry Enaineerin g Group. PLLC Mailing address: 205 S. Fuquav Avenue City: Fuguay-Varina State: NC Zip: 27526-2212 Phone number: (919) 552-0849 Email Address: andvrafcurtlenu.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Terrible Creek WWTF Permit Number: NCO066516 Owner Name: Town of Fuqua-,-Varina V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQ System Wide Collection System Permit Number(s) (if applicable). WQCS-0&93 Owner Name(s): Q n 0 1-1)71 31- vprl4ok— FORM: F fA 04- l6 Pane I of 5 Vl. GENERAL REQUIREMENTS I. If the Applicant is a Private ly-0%%ned Public Utility. has a Certificate of Public Convenience and Necessit} been attached'' [-]Yes [:]No ❑N A 2. 1 f the Applicant is a Developer of tots to be sold, has a Developer's Operational Agreement (FORM: Di;Yj been attached' ❑ Yes ❑No ©N A 3. If the Applicant is a Home Prokem Owners' Associ4lipn, has.An Operational Agreement (FORM: HOA.} been attached'-, [-]Yes [:]No ®N A 4. Origin of wastewater: (check all that apply); ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation service ❑ Hotel and.:or Motels ❑ School preschool ` day care ❑ Medical.-' dental 'veterinary facilities ❑ Swimming Pool Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool. Filter Backwash ❑ Businesses offices ` factories ❑ Nursim, Home ❑ Other ( Explain in Attachment) 5. Nature of wastewater: 100 pa Domestic Commercial a-n Commercial °:a Industrial (See 15A NCAC 02T .0103(20)) bIs there a Pretreatment Program in effect? ❑ Yes ❑ No 6_ Has a flow reduction been approved under 15A NCAC 02T .01 14(0? _Yes ❑ No y If ves, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114 ) Daily Design Flow ° t' No. of Units Flow Single Family Subdivision lots (4 bedroom) 300 -al/day 36 10,800 GPD Single Family Subdivision lots (3 bedroom) 225 gal/day 38 8550 GPD gal! t} GPD -al! GPD =at? GPD gal! GPD Tula! 19.350 GPD a See 15A NCAC 02T .01 14(b). (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum now per dwelling; proposed unknown non-residential development uses: public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T _01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures. occupancy or operation patterns, and other measured data_ 8. Wastewater generated by project: 19-350 GPD (per 15A NCAC 02T .0114) Do not include future floes or previously permitted allocations If permitted flow is zero, indicate why- ❑ Pump Station or Gravity Sewer w here flo%% will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new now expected ❑ Other (Explain); FORM- F I A 04-16 Paue 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & NIDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 3728 PVC Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & NIDC (Puma Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT l . Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(13); Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. i If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: F TA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply. %% ith all separations found in I M NCAC 02T .0''054 f) & i I 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: © Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) —74 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS-1 or WS-V), B. SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimmin+, pools 10 feet Final earth grade (vertical) 36 inches 15A NCAC 02T.03,05W contains alternatives where separations in 02T.0305(f) cannot be achieved. "Stream classifications can be identified using the Division's NC Surface Water Classifications web a+,e If noncompliance w ith 02T.03OLil2r a see Section X of this application Does the project comply with separation requirements for wetlands? (50 feet ofseparation) © Yes []No See the Division's draft separation requirements for situations "here separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes [:)No This would include Trout Buffered Streams per 15A NCAC 1B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ❑ Yes ❑ No Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T_0105JqJ 6) (additional perm its,certifications)? ❑ Yes ❑ No Per 15A NCAC 02T.0105tc)t6), directly related environmental permits or certification applications are bein- prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans. stormwater management plans. etc.). 6. Does this project include any seer collection lines that are deemed "high -priority?" Per 15A NCAC 02T_0402, "high -priority sever" means "any aerial sewer, se+ver contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the seti%er. ❑ Yes ❑ No If yes. include an attachment with details for each line, including type (aerial line, size. material. and location). High priority lines shall be inspected by the permittee or its representati%c at least once c%ery six -months and inspections documented per 15A NCAC 02T.0.103(a)(5) or the permilec's individual System -Wide Collection permit. FORM: FTA 04-16 Pa+,,e 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest %ersion and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? 0 Yes ❑ No If No, complete and submit the Variance Alternative Design Request application (VADC 10-I4) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. ?. Professional En�oineer's Certification: attest that this application for (Professional Engineer's name from Application Item I11.1.) has been reviewed by me and is accurate. complete and consistent with the information supplied in the plans, specifications. engineering calculations. and all other supporting documentation to the best of my know ledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the fast -Track Permitting of Pump Stations and Force Mains (latest version)- Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent w ith the proposed design, NOTE - In accordance with General Statutes 143-215-6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10.000. as well as civil penalties up to S25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 0:.3 r • �i�y,9AL• 823 1 S P�i;`�� Ali, Il; it���� Q•�.E� 3. Applicant's Certification per 15A NCAC 02T .0106(b): 1, _Ptlblt-C . __attest that this application for Jrl- eC 14 (Signal re Authority's' name & title from Application Item 1,3,) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete- I understand that am discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties. injunctive relief; and. -or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included. this application package will be returned to me as incomplete, NOTE .- In accordance with General Statutes Ida-? 15.6A and 143-215.6B, anv person who knowingly makes any false statement, representation, or certification in any application package shall be _guilty of Class 2 misdemeanor, which may include a fine not to exceed S 10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: FORM. FTA 04-16 Paue 5 of 5 �pF W A T -17 State of North Carolina �O G Department of Environment and Natural Resources r? r- Division of Water Quality p Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE 06-13) Project Applicant Name: Town of Fu ua -Varina Project Name for which flow is being requested: Forest Bluffs Subdivision More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the rotate of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Terrible Creek WWTP b. WWTP Facility Permit #: NCO066516 oa co All flows are in MGD c. WWTP facility's permitted flow 3.000 d. Estimated obligated flow not yet tributary to the WWTP 0.807 e. WWTP facility's actual avg. flow 1.353 f. Total flow for this specific request 0.0I9 0 g. Total actual and obligated flows to the facility 2.179, h. Percent of permitted flow used 72.6% A U II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity,* (Firm :` po, Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity"" * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Page I of 6 FTSE 06-13 Certification Statement: I Jay T. Meyers, P.C., Public Utilities certify to the best of my knowledge that the addition of Director the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. 4 i Date Page 2 of 6 I+TSE 06-13 6tate of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director November 7, 2001 Mr. Michael A. Allway, Assistant Town Manager Town of Fuquay-Varina 401 Old Honeycutt Road Fuquay-Varina, North Carolina 27526 Dear Mr. Allway: • NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT ANO NATURAL RE50URCE5 �r''i 0 8 2Ou1 Subject: Town of Fuquay-Varina Flow Reduction Approval Wake County of ru*WVa" On September 10. 2001, the Division of Water Quality Non Discharge Permitting Unit received your flow reduction request for future and present. but not yet tributary, single-family dwellings in the Town of Fuquay-Varina. The letter requests approval of a residential flow value of 220 GPD/residence for these dwellings. The information provided water use information for 2000 and actual daily waste water flow recordings for their peak month of May. Other supporting data was provided. The evaluation covered 90 homes that are representative of the subdivisions in Fuquay-Varina in accordance with 15A NCAC 2H .0219f l)(3). Based on the information submitted. the Division hereby approves the use of 75 GPD per bedroom per dwelling for residential units (225 GPD per three bedroom home) in all applicable non -discharge permit applications for future sewer line extensions and present. but not yet tributary projects for the Town of Fuquay- Varina. The Division did note that the average flaw per residence in February 2000 was 271 GPD. Regardless of the adiusted desien dailv wastewater flow rate. at no time shall the wastewater flows exceed the effluent limits defined in the Town's NPDES permit for the treatment facility or exceed the capacity of the sewers downstream of any new sewer extension. Please submit a separate letter to the Raleigh Regional Office that requests flow reductions for specific previously permitted projects (indicate permit number, ro'ect name �ermitted flow, new now under reduction and the difference between them). if you have any questions or comments regarding this matter, please contact Marie Doklovic at (919)733-5083 ext. 371. Since f' Gregory J. Thorpe, Ph.D. cc: Raleigh Regional Office Flow Reduction File 1617 Mail Service Center. Raleigh. North Carolina 27699-1617 Telephone 919-733-5083 Fax 919-715.6048 An Equal Opportunity Affirmative Action Employer SO% recyclecl/IKv post -consumer paper � - w �G C O,S. OEPARTKENT OF TMt IMitkloa II,(+_'t'.r AMC/tk QUADRANGLE V u.1. (tOIOC�[Al SURVEY {}�JJ IOpO Mo.M WRn.. ile a! W.UTl YRQS SITE LOCATION N f• T . El r I. � - - - n -' S,�• ". -.r,r r�. - ... - - -'•�f ��a ,'rf - - - 1e --- ,-i wwrMHpn. un.M v«n v«qw, �,.aT • SCALE 24" .. .,a :.:,�,�..�-.�'� �.._�, -.;.rr��—*- .r=�_�� ^�... «. ..�.��. '" ~� ......-`mid-:• •,•. 191, R7 F C-UXrY ENGINEERINGL September 26, 2019 NC Department of Environment Quality Division of Water Resources Raleigh Regional Office Water Quality Section 1628 Mad Service Center Raleigh. NC 27699-1628 (9191791-4200 RE: Forest Buff Estates Subdivision Sewer Fast Track Sanitary Sewer Application Cover Letter Dear Sir, of Erviron�'t'ental `J �CDept QUalit Sip � � 2019 1�igh R�giona14�1ce Enclosed please find documentation, design data, application fee and other resources necessary to review the Fast Track Applications for the public sanitary sewer system of the Forest Bluff Estates Subdivision, in Fuquay-Vanna, NC. The project consists of construction of 74 single family subdivision lots, with connections to an existing public sewer line at the south side of the property, which feeds to the Terrible Creek Waste Water Treatment Plant. The Forest Bluff Estates Subdivision is located at 2205 Tern Creek Drive in Fuquay-Vanna. The property involved is located within the City of Fuquay- Vanna. NC planning jurisdiction. The sanitary sewer system for tonsists of 3728 feet of 8" PVC and gravity service from the subdivision connecting to a public gravity main l ne at two locations. There are thirty 1301 new manholes to be installed. At the -ompletion of construction, the system w,sl be certified by a licensed professional engineer in accordance with NCDEO and State and local regulations. Sincere.y. a4p- Ed Loeffler. Project Manager T 19191 552-0849 205 S. Fuquay Avenue fF (9171 552-2043 Fuquay-Varina, NC 27526 CJJV�Y RENG/ Fp Es T. czzl v, o 10 \ry CA R CurrYENGINEERING TRANSMITTAL FORM TO: NC Dept. of Environmental Quality Div. of Water Resources Ra'eigh Reg,onal Office Water Qualty Section 1628 Mail Service Center Raleigh, NC 27699-1628 919-791-4200 SUBJECT: Forest Bluff Estates Subdivision CURRY PROJECT NO: 2017.069 We are sending you the following items: NC Dept of Environmental Quality DATE: September 26, 2019 SENT BY: Ed Loeffler SEp 3 0 2019 Raleigh Regional Office COPIES ITEM DESCRIPTION �rm 2 Application Fasi Track Sewer Application - Forest Bluff Estates Subdivision Forms FTSE 06-13 (Town of Fuquay-Varinal 1 Check $480.00 Fee, Sewer App.icat!on These are transmitted as checked below: For Information - Approved as Noted - Rev se and Resubmit As Requested _ Not Approved - Revise and Resubmit For Review and Comments For Record and File For Revision Submittal x For Approval For Recording Approved - For Signature, then return to - REMARKS: Attached please find the signed Fast Track Sanitary Sewer Applications for the Forest Bluff Estates Subdivision property at 2205 Terri Creek Drive in Fuquay-Var-na. Please contact me with any questions. Thank you. T 19191552-0849 205 S Fuquay Avenue F 19191 552-2043 Fuquay Varina, NC 27526 4JSRY EMG', Fp EST cz:7 'P 0 10 \lp �Q y CA R0\> Cashion Ted qWq From: Cashion, Ted Sent: Thursday, October 03, 201911:17 AM To: Jay Meyers Omeyers@fuquay-varina.org); 'andy@curryeng.com' Cc: Robinson, Jason; Deck, Erin M Subject: Forest Bluff Estates Subdivision fast track sewer extension application Jay and Andy, We are beginning our review of the subject application. However, page 3 of the application was missing. Please submit page 3 to us, you can email this page to us. ted Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashionCu@ncdenr.eov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 e:��—D E Oe9►+:TMei ¢f ln�rvrrrrrtGl C�a+'�� Subscribe to Collection System & Sewer Permitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Caw and may be disclosed to third parties unless the content is exempt by statute or other regulation.