Loading...
HomeMy WebLinkAboutNCG200339_Inspection Report_20191112ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director Biltmore Iron & Metal Co. Inc. Attention: Vonna Cloninger, CEO Post Office Box 5616 Asheville, North Carolina 28813 NORTH CAROLINA Environmental Quality November 12, 2019 Subject: Compliance Evaluation Inspection Permit: NCG200000 Certificate of Coverage: NCG200339 Buncombe County, North Carolina Dear Mrs. Cloninger: Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection I conducted at the subject facility on October 22, 2019. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact me at (828) 296-4500 or by email at Isaiah.reed@ncdenr.gov. Sincere Isaiah Reed, CPSWQ, CEP Cl, MS4CECI Environmental Specialist Land Quality Section Enclosure: Inspection Report D_EQ�� North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources 4Asheville Regional Office 1 2090 U.S. Highway 70 1 Swannanoa, North Carolina 28778 to ,CPPIXINP °v=o0i^' °""•°�`°"'"'^�0� 828.296.4500 Compliance Inspection Report Permit: NCG200339 Effective: 08/01/19 Expiration: 05/31/24 Owner: Biltmore Iron & Metal Co Inc SOC: Effective: Expiration: Facility: Biltmore Iron & Metal Co Inc County: Buncombe 1 Meadow Rd Region: Asheville Asheville NC 28803 Contact Person: Vonna Cloninger Title: Phone: 828-253-9317 Ext.11 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 10/22/2019 Primary Inspector: Isaiah L Reed Secondary Inspector(s): Certification: Phone: Entry Time: 10:30AM Exit Time: 11:30AM Phone: 828-296-4614 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Wholesale Trade of Metal Waste and Scrap Stormwater Discharge CDC Facility Status: ❑ Compliant 0 Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 Permit: NCG200339 Owner- Facility: Billmore Iron & Metal Cc Inc Inspection Date: 10/22/2019 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: On October 22, 2019 this facility was inspected for compliance. I met with Blake Cloninger on site. During the inspection, the following items were noted: 1) The Site Map is not up to date and does not accurately reflect the situation of the site. The permittee is directed to evaluate, revise and update the site plan to reflect the conditions on site. 2) The containment structure at the vehicle draining area was observed to be overtopping at the time of the inspection, and the drain screw on the side was loose ad leaking. The permittee is directed to review and revise the preventative maintenance and good houskeeping practices at the facility to address the secondary containment issues noted. 3) Employee training was not documented ad made available for review at the time of the inspection. 4) Documentation of an annual review of the Stormwater Pollution Prevention plan was not made available at the time of the inspection. The permittee is directed to locate or conduct documented training at the facility in accordance with General Permit NCG200000. 5) The stormwater basin was not far from overtopping at the far southwest end. The permittee is directed to evaluate the condition of the berm/dam between the basin and the stream and modify as needed to provide adequate storage. Please give the above items your immediate attention. If you have any questions, please contact this office at (828) 296-4614 Please give the above items your immediate attention. If you have any questions, please contact this office at (828) 296-4614 Page 2 of 3 Permit: NCG200339 Owner - Facility: ailtmore Iron & Metal Cc Inc Inspection Date: 10/22/2019 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? N ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? 0 ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ❑ 0 ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ 0 ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ N ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? 0 ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? E ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? N ❑ ❑ ❑ # Does the facility provide and document Employee Training? ❑ 0 ❑ ❑ # Does the Plan include a list of Responsible Party(s)? N ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ 0 ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ❑0 ❑ ❑ Comment: See summary for more information Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ❑ ❑ E Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? ❑ ❑ ❑ ❑ # Were all outfalls observed during the inspection? ❑ ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ ❑ ❑ Comment Page 3 of 3